2024 Exploration Program Yields up to 19.5% Cu, 9.42% Ni and 107.3 g/t PGMs from Surface Sampling at SPC Nickel's Muskox Project, Nunavut
Original announcement by tmx on
- Company
- SPC Nickel Corp.
- Ticker
- SPC
- Exchange
- TSX
- Region
- Nunavut
- Primary commodity
- Nickel
- Secondary commodities
- Copper, Palladium, Platinum, Gold, Silver, Cobalt, Zinc
- Document categories
- Drill results
- Extracted
- 2026-09-19 01:56:36 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
SPC Nickel Corp. announced high-grade assay results from its 2024 exploration program at the 100%-owned Muskox Ni-Cu-PGM Project in Nunavut. Surface grab samples yielded up to 19.5% Cu, 9.42% Ni, and 107.3 g/t PGMs, confirming widespread mineralization across multiple target areas. The company highlights the project's district-scale potential and similarities to world-class nickel-copper mining camps, with all results supported by rigorous QA/QC protocols.
Reasoning: The document reports exceptional high-grade surface grab sample results for copper, nickel, and platinum group metals from the Muskox Project, confirming widespread mineralization and significant prospectivity. The results are supported by robust QA/QC. However, the selective nature of grab samples means they are not representative of the entire property.
Positive factors
- High-grade surface grab samples for multiple commodities (Cu, Ni, PGMs)
- Confirmation of widespread high-grade mineralization in multiple geological environments
- Project described as a world-class discovery opportunity with district-scale potential
- Strong QA/QC disclosure with certified lab and QP sign-off
Negative factors
- Grab samples are selective and not representative of mineralized zones, limiting direct resource implications
Facts used in scoring: 152
Extracted facts
Stored fact records: 152. Some facts used in scoring do not have a stored record.
Drill Results (152)
M017824Muskox · copperGrade: 19.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 19.5
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Exceptional copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“19.50”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017824Muskox · nickelGrade: 0.06Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.06
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with very high copper, indicating a different mineralization style.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.06”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017824MuskoxView all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: Cobalt is below detection limit in this sample, which is not unusual for a copper-dominant sample.
Negative factors
- Cobalt grade is below detection limit
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“<0.01”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017824Muskox · palladiumGrade: 6.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 6.4
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“6.40”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017824Muskox · platinumGrade: 0.87Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.87
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate platinum grade, adding to the PGM potential of the Equinox Target.
Positive factors
- Moderate platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.87”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017824Muskox · goldGrade: 0.41Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Gold grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.41”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017824Muskox · silverGrade: 27.5Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017824
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 27.5
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“27.5”
Context: M017824
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · copperGrade: 9.21Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 9.21
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Very strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“9.21”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · nickelGrade: 9.42Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 9.42
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high nickel grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Exceptional nickel grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“9.42”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · cobaltGrade: 0.21Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.21
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate cobalt grade, which is a common association with high-grade nickel mineralization.
Positive factors
- Moderate cobalt grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.21”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · palladiumGrade: 11.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 11.1
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Very strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“11.10”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · platinumGrade: 0.54Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is modest, but it is part of a polymetallic sample with high copper, nickel, and palladium.
Negative factors
- Platinum grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.54”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · goldGrade: 0.32Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is modest, but it is part of a polymetallic sample with high copper, nickel, and palladium.
Negative factors
- Gold grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.32”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017766Muskox · silverGrade: 34.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017766
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 34.9
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper, nickel, and palladium.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“34.9”
Context: M017766
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · copperGrade: 17.35Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 17.35
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Exceptional copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“17.35”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · nickelGrade: 0.32Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.32
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is modest, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Nickel grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.32”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · cobaltGrade: 0.02Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.02
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.02”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · palladiumGrade: 65Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 65
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high palladium grade, indicating significant PGM mineralization at the Equinox Target.
Positive factors
- Exceptional palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“65.00”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · platinumGrade: 7.79Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 7.79
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong platinum grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Very strong platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“7.79”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · goldGrade: 3.62Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 3.62
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong gold grade, adding to the precious metal potential of the Equinox Target.
Positive factors
- Strong gold grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“3.62”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017821Muskox · silverGrade: 13.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017821
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 13.8
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“13.8”
Context: M017821
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · copperGrade: 13Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 13
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Very strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“13.00”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · nickelGrade: 0.06Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.06
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.06”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · cobaltGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is very low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Cobalt grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.00”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · palladiumGrade: 16Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 16
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Very strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“16.00”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · platinumGrade: 1.83Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.83
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong platinum grade, adding to the PGM potential of the Equinox Target.
Positive factors
- Strong platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.83”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · goldGrade: 0.49Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Gold grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.49”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017818Muskox · silverGrade: 46Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017818
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 46
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“46.0”
Context: M017818
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · copperGrade: 8.43Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 8.43
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Very strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“8.43”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · nickelGrade: 0.13Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.13
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.13”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · palladiumGrade: 42.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 42.4
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high palladium grade, indicating significant PGM mineralization at the Equinox Target.
Positive factors
- Exceptional palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“42.40”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · platinumGrade: 4.47Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 4.47
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong platinum grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“4.47”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · goldGrade: 3.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 3.3
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong gold grade, adding to the precious metal potential of the Equinox Target.
Positive factors
- Strong gold grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“3.30”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017820Muskox · silverGrade: 25.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017820
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 25.8
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“25.8”
Context: M017820
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · copperGrade: 7.89Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 7.89
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Very strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“7.89”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · nickelGrade: 0.26Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.26
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.26”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and PGMs.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · palladiumGrade: 93.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 93.1
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high palladium grade, indicating significant PGM mineralization at the Equinox Target.
Positive factors
- Exceptional palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“93.10”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · platinumGrade: 6.69Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 6.69
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong platinum grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Very strong platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“6.69”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · goldGrade: 7.57Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 7.57
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong gold grade, adding to the precious metal potential of the Equinox Target.
Positive factors
- Very strong gold grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“7.57”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017823Muskox · silverGrade: 10.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017823
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 10.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“10.7”
Context: M017823
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · copperGrade: 6.43Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 6.43
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“6.43”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · nickelGrade: 1.06Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.06
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong nickel grade, indicating significant mineralization at the Equinox Target.
Positive factors
- Strong nickel grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.06”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · cobaltGrade: 0.06Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.06
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Cobalt grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.06”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · palladiumGrade: 4.76Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 4.76
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“4.76”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · platinumGrade: 0.64Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.64
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is modest, but it is part of a polymetallic sample with high copper, nickel, and palladium.
Negative factors
- Platinum grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.64”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · goldGrade: 0.26Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is low, but it is part of a polymetallic sample with high copper, nickel, and palladium.
Negative factors
- Gold grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.26”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017819Muskox · silverGrade: 18Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017819
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 18
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper, nickel, and palladium.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“18.0”
Context: M017819
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · copperGrade: 6.23Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 6.23
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“6.23”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · nickelGrade: 0.11Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.11
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.11”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · palladiumGrade: 29.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 29.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows an exceptionally high palladium grade, indicating significant PGM mineralization at the Equinox Target.
Positive factors
- Exceptional palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“29.70”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · platinumGrade: 1.97Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.97
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong platinum grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.97”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · goldGrade: 2.02Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.02
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong gold grade, adding to the precious metal potential of the Equinox Target.
Positive factors
- Strong gold grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.02”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017822Muskox · silverGrade: 17.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017822
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 17.3
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“17.3”
Context: M017822
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · copperGrade: 5.27Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 5.27
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“5.27”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · nickelGrade: 0.47Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.47
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Nickel grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.47”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · cobaltGrade: 0.02Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.02
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.02”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · palladiumGrade: 8.2Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 8.2
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“8.20”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · platinumGrade: 0.81Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate platinum grade, adding to the PGM potential of the Equinox Target.
Positive factors
- Moderate platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.81”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · goldGrade: 0.75Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.75
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Gold grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.75”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017835Muskox · silverGrade: 26.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017835
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 26.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“26.7”
Context: M017835
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833Muskox · copperGrade: 4.72Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 4.72
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“4.72”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833Muskox · nickelGrade: 0.03Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.03
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.03”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833MuskoxView all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: Cobalt is below detection limit in this sample, which is not unusual for a copper-dominant sample.
Negative factors
- Cobalt grade is below detection limit
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“<0.01”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833Muskox · palladiumGrade: 8.64Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 8.64
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“8.64”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833Muskox · platinumGrade: 0.66Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.66
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Platinum grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.66”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833Muskox · goldGrade: 0.78Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.78
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Gold grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.78”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017833Muskox · silverGrade: 12.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017833
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 12.4
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and PGMs.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“12.4”
Context: M017833
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · copperGrade: 2.8Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.8
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.80”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · nickelGrade: 1.73Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.73
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong nickel grade, indicating significant mineralization at the Equinox Target.
Positive factors
- Strong nickel grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.73”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · cobaltGrade: 0.04Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.04
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.04”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · palladiumGrade: 9.89Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 9.89
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong palladium grade, contributing to the overall high-grade PGM mineralization at the Equinox Target.
Positive factors
- Strong palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“9.89”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · platinumGrade: 1.08Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.08
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate platinum grade, adding to the PGM potential of the Equinox Target.
Positive factors
- Moderate platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.08”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · goldGrade: 0.76Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.76
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is modest, but it is part of a polymetallic sample with high copper, nickel, and PGMs.
Negative factors
- Gold grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.76”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017768Muskox · silverGrade: 7.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017768
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 7.3
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is low, but it is part of a polymetallic sample with high copper, nickel, and PGMs.
Negative factors
- Silver grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“7.3”
Context: M017768
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · copperGrade: 2.81Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.81
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.81”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · nickelGrade: 0.43Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.43
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is modest, but it is part of a polymetallic sample with high copper.
Negative factors
- Nickel grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.43”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · cobaltGrade: 0.03Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.03
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with high copper.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.03”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · palladiumGrade: 0.46Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is low, but it is part of a polymetallic sample with high copper.
Negative factors
- Palladium grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.46”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · platinumGrade: 0.06Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with high copper.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.06”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · goldGrade: 0.05Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with high copper.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.05”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017769Muskox · silverGrade: 2.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017769
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.9
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with high copper.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.9”
Context: M017769
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · copperGrade: 1.53Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.53
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Moderate copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.53”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · nickelGrade: 1.42Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.42
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong nickel grade, indicating significant mineralization at the Equinox Target.
Positive factors
- Strong nickel grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.42”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · cobaltGrade: 0.14Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.14
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is modest, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Cobalt grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.14”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · palladiumGrade: 0.19Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is low, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Palladium grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.19”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · platinumGrade: 0Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.00”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · goldGrade: 0.01Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017765Muskox · silverGrade: 2.3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017765
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.3
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with high copper and nickel.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.3”
Context: M017765
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · copperGrade: 1.67Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.67
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Moderate copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.67”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · nickelGrade: 0.19Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.19
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.19”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · palladiumGrade: 1.59Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.59
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is modest, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Palladium grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.59”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · platinumGrade: 0.07Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.07”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · goldGrade: 0.16Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.16”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017825Muskox · silverGrade: 5.8Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017825
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 5.8
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Silver grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“5.8”
Context: M017825
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · copperGrade: 1.61Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.61
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Moderate copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.61”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · nickelGrade: 0.12Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.12
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.12”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · cobaltGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Cobalt grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.00”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · palladiumGrade: 1.98Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.98
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is modest, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Palladium grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.98”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · platinumGrade: 0.1Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.10”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · goldGrade: 0.13Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.13”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017827Muskox · silverGrade: 11.4Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017827
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 11.4
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is modest, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Silver grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“11.4”
Context: M017827
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · copperGrade: 0.91Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.91
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a modest copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Negative factors
- Copper grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.91”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · nickelGrade: 0.81Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.81
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate nickel grade, indicating mineralization at the Equinox Target.
Positive factors
- Moderate nickel grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.81”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · cobaltGrade: 0.06Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.06
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is modest, but it is part of a polymetallic sample with moderate copper and nickel.
Negative factors
- Cobalt grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.06”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · palladiumGrade: 0.52Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.52
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper and nickel.
Negative factors
- Palladium grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.52”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · platinumGrade: 0.03Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper and nickel.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.03”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · goldGrade: 0.04Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper and nickel.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.04”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017836Muskox · silverGrade: 1.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017836
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper and nickel.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.7”
Context: M017836
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · copperGrade: 1.5Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.5
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Positive factors
- Moderate copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.50”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · nickelGrade: 0.13Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.13
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.13”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · palladiumGrade: 2.33Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.33
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is modest, but it is part of a polymetallic sample with moderate copper.
Positive factors
- Moderate palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.33”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · platinumGrade: 0.04Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.04”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · goldGrade: 0.18Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.18”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017764Muskox · silverGrade: 2.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017764
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.9
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.9”
Context: M017764
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · copperGrade: 1.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a modest copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Negative factors
- Copper grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.01”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · nickelGrade: 0.14Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.14
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with modest copper.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.14”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with modest copper.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · palladiumGrade: 2.37Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.37
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is modest, but it is part of a polymetallic sample with modest copper.
Positive factors
- Moderate palladium grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.37”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · platinumGrade: 0.12Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with modest copper.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.12”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · goldGrade: 0.19Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with modest copper.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.19”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017767Muskox · silverGrade: 3Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017767
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 3
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with modest copper.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“3.0”
Context: M017767
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · copperGrade: 0.57Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.57
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a low copper grade, indicating mineralization at the Equinox Target, though its representativeness is limited by the sample type.
Negative factors
- Copper grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.57”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · nickelGrade: 0.55Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.55
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a modest nickel grade, indicating mineralization at the Equinox Target.
Negative factors
- Nickel grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.55”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · cobaltGrade: 0.09Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.09
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is modest, but it is part of a polymetallic sample with low copper and modest nickel.
Negative factors
- Cobalt grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.09”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · palladiumGrade: 0.07Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is very low, but it is part of a polymetallic sample with low copper and modest nickel.
Negative factors
- Palladium grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.07”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · platinumGrade: 0Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is very low, but it is part of a polymetallic sample with low copper and modest nickel.
Negative factors
- Platinum grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.00”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · goldGrade: 0.01Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with low copper and modest nickel.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017817Muskox · silverGrade: 0.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017817
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.9
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Equinox Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with low copper and modest nickel.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.9”
Context: M017817
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · copperGrade: 9.02Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 9.02
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong copper grade, indicating significant mineralization at the Pyrrhotite Lake Target, though its representativeness is limited by the sample type.
Positive factors
- Very strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“9.02”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · nickelGrade: 0.11Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.11
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with very high copper.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.11”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · cobaltGrade: 0.01Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.01
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is low, but it is part of a polymetallic sample with very high copper.
Negative factors
- Cobalt grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.01”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · palladiumGrade: 0.03Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is very low, but it is part of a polymetallic sample with very high copper.
Negative factors
- Palladium grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.03”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · platinumGrade: 1.88Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.88
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong platinum grade, contributing to the PGM potential of the Pyrrhotite Lake Target.
Positive factors
- Strong platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.88”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · goldGrade: 0.29Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and platinum.
Negative factors
- Gold grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.29”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017839Muskox · silverGrade: 5.7Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017839
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 5.7
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is low, but it is part of a polymetallic sample with very high copper and platinum.
Negative factors
- Silver grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“5.7”
Context: M017839
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · copperGrade: 6.45Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 6.45
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a strong copper grade, indicating significant mineralization at the Pyrrhotite Lake Target, though its representativeness is limited by the sample type.
Positive factors
- Strong copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“6.45”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · nickelGrade: 0.05Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.05
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The nickel grade in this grab sample is low, but it is part of a polymetallic sample with high copper.
Negative factors
- Nickel grade is low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.05”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · cobaltGrade: 0Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The cobalt grade in this grab sample is very low, but it is part of a polymetallic sample with high copper.
Negative factors
- Cobalt grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.00”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · palladiumGrade: 0.07Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is very low, but it is part of a polymetallic sample with high copper.
Negative factors
- Palladium grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.07”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · platinumGrade: 1.02Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate platinum grade, adding to the PGM potential of the Pyrrhotite Lake Target.
Positive factors
- Moderate platinum grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“1.02”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · goldGrade: 0.19Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- gold
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The gold grade in this grab sample is very low, but it is part of a polymetallic sample with high copper and platinum.
Negative factors
- Gold grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.19”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017840Muskox · silverGrade: 2.9Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017840
- Project
- Muskox
- Commodity
- silver
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.9
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The silver grade in this grab sample is very low, but it is part of a polymetallic sample with high copper and platinum.
Negative factors
- Silver grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.9”
Context: M017840
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017774Muskox · copperGrade: 2.09Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017774
- Project
- Muskox
- Commodity
- copper
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.09
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate copper grade, indicating mineralization at the Pyrrhotite Lake Target, though its representativeness is limited by the sample type.
Positive factors
- Moderate copper grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.09”
Context: M017774
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017774Muskox · nickelGrade: 2.71Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017774
- Project
- Muskox
- Commodity
- nickel
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 2.71
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a very strong nickel grade, indicating significant mineralization at the Pyrrhotite Lake Target.
Positive factors
- Very strong nickel grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“2.71”
Context: M017774
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017774Muskox · cobaltGrade: 0.22Grade Unit: %View all detailsHide details
Identity
- Hole ID
- M017774
- Project
- Muskox
- Commodity
- cobalt
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.22
- Grade Unit
- %
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: This grab sample shows a moderate cobalt grade, which is a common association with high-grade nickel mineralization.
Positive factors
- Moderate cobalt grade for a surface sample
Negative factors
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.22”
Context: M017774
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017774Muskox · palladiumGrade: 0.03Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017774
- Project
- Muskox
- Commodity
- palladium
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The palladium grade in this grab sample is very low, but it is part of a polymetallic sample with moderate copper and very high nickel.
Negative factors
- Palladium grade is very low for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.03”
Context: M017774
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
M017774Muskox · platinumGrade: 0.63Grade Unit: g/tView all detailsHide details
Identity
- Hole ID
- M017774
- Project
- Muskox
- Commodity
- platinum
- Region
- canada_nu
- Reported Region
- canada_nu
- Ticker
- SPC
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
Classification
- Sample Type
- surface
Location
- Location
- Pyrrhotite Lake Target
- Loc. Source
- document
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-09-09T00:00:00.000Z
Reasoning: The platinum grade in this grab sample is modest, but it is part of a polymetallic sample with moderate copper and very high nickel.
Negative factors
- Platinum grade is modest for a surface sample
- Grab sample is selective and not representative of mineralized zones
Evidence · table
“0.63”
Context: M017774
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.