Abasca Resources Announces Completion of Winter Exploration Program and Arrangement of Non-Brokered Private Placement of up to $2.5 Million

Original announcement by tmx on

Company
Abasca Resources Inc.
Ticker
ABA
Exchange
TSX
Region
Saskatchewan
Primary commodity
Graphite
Secondary commodities
Sulfur
Document categories
Drill results, Capital raise, Resource update
Extracted
2026-09-19 07:34:51 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Abasca Resources announced the completion of its Winter 2026 exploration program at the Loki Flake Graphite Deposit in northern Saskatchewan, successfully extending the deposit's strike length by 200 meters and confirming graphite mineralization at the Thor Zone. The company also arranged a non-brokered private placement of up to $2.5 million to fund ongoing exploration. Drill results include several high-grade graphite intercepts, though true widths were not reported.

Reasoning: The announcement reports positive drill results extending the Loki Deposit and confirming mineralization at the Thor Zone, supported by disclosed QA/QC. The private placement provides funding for continued exploration. However, the lack of true width disclosure for intercepts and the historical nature of the resource estimate temper the overall positive sentiment.

Positive factors

  • Successful extension of the Loki Deposit by 200 m of strike-length, indicating growth potential.
  • Confirmation of continuity of graphite mineralization at the Thor Zone.
  • High-grade graphite intercepts, with several exceeding 5% Cg.
  • QA/QC procedures are disclosed, including use of an ISO/IEC 17025:2017 accredited lab and insertion of blanks, standards, and repeats.
  • The private placement secures funding for ongoing exploration.

Negative factors

  • Drill intercepts are reported as downhole lengths, with no true width provided, which may overstate true thickness.
  • The resource estimate mentioned is historical (2025) and inferred, not a new update.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 41

Extracted facts

Stored fact records: 40. Some facts used in scoring do not have a stored record.

Drill Results (39)

KLS-26-104Loki Flake Graphite Deposit · graphiteGrade: 5.38Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
KLS-26-104
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
5.38
Grade Unit
%
Intercept
6 m
From
59 m
To
65 m
Hole Depth
126 m
Intercept Depth
59 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-104:59-65
Mining Method
unknown

Location

Easting
446138
Northing
6329963
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
548 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a moderate length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (5.38% Cg) for flake graphite deposits.
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“5.38”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-104Loki Flake Graphite Deposit · sulfurGrade: 0.06Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
KLS-26-104
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.06
Grade Unit
%
Intercept
6 m
From
59 m
To
65 m
Hole Depth
126 m
Intercept Depth
59 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-104:59-65
Mining Method
unknown

Location

Easting
446138
Northing
6329963
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
548 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.06”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-104Loki Flake Graphite Deposit · graphiteGrade: 6.51Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
KLS-26-104
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
6.51
Grade Unit
%
Intercept
6 m
From
69 m
To
75 m
Hole Depth
126 m
Intercept Depth
69 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-104:69-75
Mining Method
unknown

Location

Easting
446138
Northing
6329963
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
548 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a strong grade over a moderate length, contributing positively to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (6.51% Cg) for flake graphite deposits.
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“6.51”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-104Loki Flake Graphite Deposit · sulfurGrade: 0.16Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
KLS-26-104
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.16
Grade Unit
%
Intercept
6 m
From
69 m
To
75 m
Hole Depth
126 m
Intercept Depth
69 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-104:69-75
Mining Method
unknown

Location

Easting
446138
Northing
6329963
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
548 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.16”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · graphiteGrade: 3.3Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
3.3
Grade Unit
%
Intercept
1 m
From
87 m
To
88 m
Hole Depth
195 m
Intercept Depth
87 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:87-88
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a moderate grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“3.30”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · sulfurGrade: 0.28Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.28
Grade Unit
%
Intercept
1 m
From
87 m
To
88 m
Hole Depth
195 m
Intercept Depth
87 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:87-88
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“0.28”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · graphiteGrade: 4.38Grade Unit: %Intercept: 17 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
4.38
Grade Unit
%
Intercept
17 m
From
102 m
To
119 m
Hole Depth
195 m
Intercept Depth
102 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:102-119
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a significant length, contributing positively to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • Good grade and significant intercept length (17m).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“4.38”

Context: 17.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · sulfurGrade: 0.32Grade Unit: %Intercept: 17 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.32
Grade Unit
%
Intercept
17 m
From
102 m
To
119 m
Hole Depth
195 m
Intercept Depth
102 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:102-119
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.32”

Context: 17.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.

Evidence · text

“Composite intervals are calculated using a 3.0 % Cg cut-off and may include a maximum of 2.0 m internal dilution.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · graphiteGrade: 5.04Grade Unit: %Intercept: 3 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
5.04
Grade Unit
%
Intercept
3 m
From
122 m
To
125 m
Hole Depth
195 m
Intercept Depth
122 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:122-125
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (5.04% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“5.04”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · sulfurGrade: 0.38Grade Unit: %Intercept: 3 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.38
Grade Unit
%
Intercept
3 m
From
122 m
To
125 m
Hole Depth
195 m
Intercept Depth
122 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:122-125
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“0.38”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · graphiteGrade: 5.02Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
5.02
Grade Unit
%
Intercept
7 m
From
133 m
To
140 m
Hole Depth
195 m
Intercept Depth
133 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:133-140
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a moderate length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (5.02% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“5.02”

Context: 7.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-105Loki Flake Graphite Deposit · sulfurGrade: 0.96Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
KLS-26-105
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.96
Grade Unit
%
Intercept
7 m
From
133 m
To
140 m
Hole Depth
195 m
Intercept Depth
133 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-105:133-140
Mining Method
unknown

Location

Easting
446089
Northing
6329887
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
546 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.96”

Context: 7.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · graphiteGrade: 3.61Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
3.61
Grade Unit
%
Intercept
1 m
From
122 m
To
123 m
Hole Depth
252 m
Intercept Depth
122 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:122-123
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a moderate grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“3.61”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · sulfurGrade: 0.6Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.6
Grade Unit
%
Intercept
1 m
From
122 m
To
123 m
Hole Depth
252 m
Intercept Depth
122 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:122-123
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“0.60”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · graphiteGrade: 3.2Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
3.2
Grade Unit
%
Intercept
2 m
From
128 m
To
130 m
Hole Depth
252 m
Intercept Depth
128 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:128-130
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a moderate grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“3.20”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · sulfurGrade: 0.39Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.39
Grade Unit
%
Intercept
2 m
From
128 m
To
130 m
Hole Depth
252 m
Intercept Depth
128 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:128-130
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“0.39”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · graphiteGrade: 4.58Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
4.58
Grade Unit
%
Intercept
6 m
From
178 m
To
184 m
Hole Depth
252 m
Intercept Depth
178 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:178-184
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a moderate length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • Good grade graphite intercept (4.58% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“4.58”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · sulfurGrade: 0.61Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.61
Grade Unit
%
Intercept
6 m
From
178 m
To
184 m
Hole Depth
252 m
Intercept Depth
178 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:178-184
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.61”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · graphiteGrade: 3.69Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
3.69
Grade Unit
%
Intercept
5 m
From
187 m
To
192 m
Hole Depth
252 m
Intercept Depth
187 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:187-192
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a moderate grade over a moderate length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“3.69”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · sulfurGrade: 0.67Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.67
Grade Unit
%
Intercept
5 m
From
187 m
To
192 m
Hole Depth
252 m
Intercept Depth
187 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:187-192
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.67”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · graphiteGrade: 6.68Grade Unit: %Intercept: 16 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
6.68
Grade Unit
%
Intercept
16 m
From
197 m
To
213 m
Hole Depth
252 m
Intercept Depth
197 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:197-213
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a strong grade over a significant length, contributing positively to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (6.68% Cg) over a significant length (16m).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“6.68”

Context: 16.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-106Loki Flake Graphite Deposit · sulfurGrade: 1.34Grade Unit: %Intercept: 16 mView all details
Link to this fact

Identity

Hole ID
KLS-26-106
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
1.34
Grade Unit
%
Intercept
16 m
From
197 m
To
213 m
Hole Depth
252 m
Intercept Depth
197 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-106:197-213
Mining Method
unknown

Location

Easting
446027
Northing
6329795
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
540 m
Azimuth
35 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“1.34”

Context: 16.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-107Loki Flake Graphite Deposit · graphiteGrade: 3.08Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-107
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
3.08
Grade Unit
%
Intercept
1 m
From
198 m
To
199 m
Hole Depth
308 m
Intercept Depth
198 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-107:198-199
Mining Method
unknown

Location

Easting
445976
Northing
6329716
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
539 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a moderate grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“3.08”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-107Loki Flake Graphite Deposit · sulfurGrade: 0.39Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-107
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.39
Grade Unit
%
Intercept
1 m
From
198 m
To
199 m
Hole Depth
308 m
Intercept Depth
198 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-107:198-199
Mining Method
unknown

Location

Easting
445976
Northing
6329716
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
539 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“0.39”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-107Loki Flake Graphite Deposit · graphiteGrade: 4.89Grade Unit: %Intercept: 23.1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-107
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
4.89
Grade Unit
%
Intercept
23.1 m
From
215.9 m
To
239 m
Hole Depth
308 m
Intercept Depth
215.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-107:215.9-239
Mining Method
unknown

Location

Easting
445976
Northing
6329716
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
539 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a significant length, contributing positively to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • Good grade graphite intercept (4.89% Cg) over a significant length (23.1m).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“4.89”

Context: 23.10

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-107Loki Flake Graphite Deposit · sulfurGrade: 0.73Grade Unit: %Intercept: 23.1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-107
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.73
Grade Unit
%
Intercept
23.1 m
From
215.9 m
To
239 m
Hole Depth
308 m
Intercept Depth
215.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-107:215.9-239
Mining Method
unknown

Location

Easting
445976
Northing
6329716
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
539 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.73”

Context: 23.10

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-107Loki Flake Graphite Deposit · graphiteGrade: 6.28Grade Unit: %Intercept: 12.5 mView all details
Link to this fact

Identity

Hole ID
KLS-26-107
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
6.28
Grade Unit
%
Intercept
12.5 m
From
242 m
To
254.5 m
Hole Depth
308 m
Intercept Depth
242 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-107:242-254.5
Mining Method
unknown

Location

Easting
445976
Northing
6329716
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
539 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a strong grade over a significant length, contributing positively to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (6.28% Cg) over a significant length (12.5m).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“6.28”

Context: 12.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-107Loki Flake Graphite Deposit · sulfurGrade: 1.31Grade Unit: %Intercept: 12.5 mView all details
Link to this fact

Identity

Hole ID
KLS-26-107
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
1.31
Grade Unit
%
Intercept
12.5 m
From
242 m
To
254.5 m
Hole Depth
308 m
Intercept Depth
242 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-107:242-254.5
Mining Method
unknown

Location

Easting
445976
Northing
6329716
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
539 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“1.31”

Context: 12.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-108Loki Flake Graphite Deposit · graphiteGrade: 5.1Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
KLS-26-108
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
5.1
Grade Unit
%
Intercept
0.8 m
From
37.2 m
To
38 m
Hole Depth
141 m
Intercept Depth
37.2 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-108:37.2-38
Mining Method
unknown

Location

Easting
446202
Northing
6329878
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
538 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a very narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (5.10% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Very narrow intercept length.

Evidence · table

“5.10”

Context: 0.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-108Loki Flake Graphite Deposit · graphiteGrade: 5.53Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-108
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
5.53
Grade Unit
%
Intercept
1 m
From
56 m
To
57 m
Hole Depth
141 m
Intercept Depth
56 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-108:56-57
Mining Method
unknown

Location

Easting
446202
Northing
6329878
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
538 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (5.53% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“5.53”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-109Loki Flake Graphite Deposit · graphiteGrade: 3.22Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-109
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
3.22
Grade Unit
%
Intercept
1 m
From
45 m
To
46 m
Hole Depth
176 m
Intercept Depth
45 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-109:45-46
Mining Method
unknown

Location

Easting
446176
Northing
6329821
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
537 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a moderate grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“3.22”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-109Loki Flake Graphite Deposit · sulfurGrade: 0.44Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
KLS-26-109
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.44
Grade Unit
%
Intercept
1 m
From
45 m
To
46 m
Hole Depth
176 m
Intercept Depth
45 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-109:45-46
Mining Method
unknown

Location

Easting
446176
Northing
6329821
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
537 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“0.44”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-109Loki Flake Graphite Deposit · graphiteGrade: 4.59Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
KLS-26-109
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
4.59
Grade Unit
%
Intercept
2 m
From
68 m
To
70 m
Hole Depth
176 m
Intercept Depth
68 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-109:68-70
Mining Method
unknown

Location

Easting
446176
Northing
6329821
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
537 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a narrow length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.
  • Narrow intercept length.

Evidence · table

“4.59”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-110Loki Flake Graphite Deposit · graphiteGrade: 5.91Grade Unit: %Intercept: 5.7 mView all details
Link to this fact

Identity

Hole ID
KLS-26-110
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
5.91
Grade Unit
%
Intercept
5.7 m
From
123.3 m
To
129 m
Hole Depth
185 m
Intercept Depth
123.3 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-110:123.3-129
Mining Method
unknown

Location

Easting
446114
Northing
6329736
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
541 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a moderate length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • High-grade graphite intercept (5.91% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“5.91”

Context: 5.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-110Loki Flake Graphite Deposit · sulfurGrade: 0.18Grade Unit: %Intercept: 5.7 mView all details
Link to this fact

Identity

Hole ID
KLS-26-110
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.18
Grade Unit
%
Intercept
5.7 m
From
123.3 m
To
129 m
Hole Depth
185 m
Intercept Depth
123.3 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-110:123.3-129
Mining Method
unknown

Location

Easting
446114
Northing
6329736
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
541 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.18”

Context: 5.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-110Loki Flake Graphite Deposit · graphiteGrade: 4.63Grade Unit: %Intercept: 8 mView all details
Link to this fact

Identity

Hole ID
KLS-26-110
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
4.63
Grade Unit
%
Intercept
8 m
From
136 m
To
144 m
Hole Depth
185 m
Intercept Depth
136 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-110:136-144
Mining Method
unknown

Location

Easting
446114
Northing
6329736
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
541 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a moderate length, contributing to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • Good grade graphite intercept (4.63% Cg).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“4.63”

Context: 8.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-110Loki Flake Graphite Deposit · sulfurGrade: 0.3Grade Unit: %Intercept: 8 mView all details
Link to this fact

Identity

Hole ID
KLS-26-110
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.3
Grade Unit
%
Intercept
8 m
From
136 m
To
144 m
Hole Depth
185 m
Intercept Depth
136 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-110:136-144
Mining Method
unknown

Location

Easting
446114
Northing
6329736
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
541 m
Azimuth
35 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.30”

Context: 8.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-111Loki Flake Graphite Deposit · graphiteGrade: 4.88Grade Unit: %Intercept: 19.5 mView all details
Link to this fact

Identity

Hole ID
KLS-26-111
Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
4.88
Grade Unit
%
Intercept
19.5 m
From
216.5 m
To
236 m
Hole Depth
323 m
Intercept Depth
216.5 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-111:216.5-236
Mining Method
unknown

Location

Easting
446042
Northing
6329642
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
541 m
Azimuth
35 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: This intercept shows a good grade over a significant length, contributing positively to the deposit's extension. QA/QC is disclosed, but true width is not.

Positive factors

  • Good grade graphite intercept (4.88% Cg) over a significant length (19.5m).
  • QA/QC procedures disclosed and lab is ISO/IEC 17025:2017 accredited.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“4.88”

Context: 19.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

KLS-26-111Loki Flake Graphite Deposit · sulfurGrade: 0.89Grade Unit: %Intercept: 19.5 mView all details
Link to this fact

Identity

Hole ID
KLS-26-111
Project
Loki Flake Graphite Deposit
Commodity
sulfur
Region
canada_sk
Reported Region
canada_sk
Ticker
ABA

Geometry

Grade
0.89
Grade Unit
%
Intercept
19.5 m
From
216.5 m
To
236 m
Hole Depth
323 m
Intercept Depth
216.5 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
KLS-26-111:216.5-236
Mining Method
unknown

Location

Easting
446042
Northing
6329642
CRS
UTM NAD 83 Zone 13N
EPSG
26913
Elevation
541 m
Azimuth
35 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Compositing

Cutoff Grade
3
Cutoff Unit
% Cg
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: Low sulfur grade, but reported as a byproduct. QA/QC is disclosed, but true width is not.

Negative factors

  • Apparent width only, true thickness not reported.

Evidence · table

“0.89”

Context: 19.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'All lengths are as measured downhole and do not represent true thickness.'

Evidence · text

“All lengths are as measured downhole and do not represent true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Samples were sent to SRC Geoanalytical Laboratories, an independent laboratory accredited under ISO/IEC 17025:2017, and included insertion of blanks, standard reference materials, and repeats.

Evidence · text

“Collected samples were sent to SRC Geoanalytical Laboratories in Saskatoon, Saskatchewan, an independent laboratory accredited under ISO/IEC 17025:2017 for preparation and ICP-MS multi-element analysis, boron by fusion as well as graphite content (% Cg) and total sulphur by LECO. Samples were collected in accordance with industry-standard quality assurance / quality control practices and included the insertion of blanks, standard reference materials, and repeats into the sample stream at regular intervals.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights Completed 4,922 m of drilling at the 100%-owned Loki Flake Graphite Deposit, Saskatchewan 4,517 m in 18 diamo"

Resource Estimates (1)

inferredLoki Flake Graphite Deposit · graphiteTonnes: 11310000Grade: 7.65Grade Unit: % CgHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Project
Loki Flake Graphite Deposit
Commodity
graphite
Region
canada_sk
Reported Region
Saskatchewan
Ticker
ABA

Resource scope

Estimate type
resource
Effective date
2025-04-10T00:00:00.000Z
Reporting standards
ni_43_101
QP Signed
Yes
Qualified person names
Brian McEwan
Resource group id
resource:0fde3d544be5cc4bf03d
Deposit or zone
Loki Flake Graphite

Resource Data

Category
inferred
Tonnes
11310000
Grade
7.65
Grade Unit
% Cg

Prior Estimate

Resource Date
2025-04-10

Review

Needs Review
Yes
Review Reason
historical_restatement
Historical
Yes
Historical Source Date
2025-05-29T00:00:00.000Z

Dates

Event date
2026-04-14T00:00:00.000Z

Reasoning: The document references a substantial historical inferred resource, which provides a baseline but lacks the confidence of higher categories or a new update.

Positive factors

  • Significant inferred resource tonnage and grade for graphite.

Negative factors

  • The resource is entirely in the inferred category, indicating lower geological confidence.
  • The estimate is historical, not a new update in this release.

Evidence · text

“KLS is also host to the Loki Flake Graphite Deposit comprising a total inferred resource of 11.31 Mt at 7.65 % Cg. Please refer to the technical report dated May 29, 2025, with an effective date of April 10, 2025 and titled "Technical Report on the Key Lake South Project with Initial Mineral Resource Estimate for the Loki Flake Graphite Deposit, Saskatchewan, Canada", filed under the Company's profile on the SEDAR+ website, for further information about the resource estimate.”

Tags used in scoring

Inferred Resourcenegative

Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.

Why it applies: The resource is described as 'a total inferred resource of 11.31 Mt at 7.65 % Cg'.

Evidence · text

“a total inferred resource of 11.31 Mt at 7.65 % Cg”

All Inferrednegative

M&I share below the weak bound — very early stage, no engineering confidence.

Why it applies: The resource is described as 'a total inferred resource of 11.31 Mt at 7.65 % Cg', indicating 100% inferred category.

Evidence · text

“a total inferred resource of 11.31 Mt at 7.65 % Cg”

Stale Estimatenegative

Effective date is >2 years old — data currency concern, may not reflect current geological understanding.

Why it applies: The effective date of the resource estimate is April 10, 2025, which is over a year old relative to the publication date of April 14, 2026.

Evidence · text

“effective date of April 10, 2025”

NI 43-101 Compliantpositive

Resource estimate prepared in compliance with NI 43-101 (Canada) — high reporting standard.

Why it applies: The resource estimate refers to a 'technical report dated May 29, 2025, with an effective date of April 10, 2025 and titled "Technical Report on the Key Lake South Project with Initial Mineral Resource Estimate for the Loki Flake Graphite Deposit, Saskatchewan, Canada", filed under the Company's profile on the SEDAR+ website, for further information about the resource estimate.' This implies NI 43-101 compliance.

Evidence · text

“technical report dated May 29, 2025, with an effective date of April 10, 2025 and titled "Technical Report on the Key Lake South Project with Initial Mineral Resource Estimate for the Loki Flake Graphite Deposit, Saskatchewan, Canada", filed under the Company's profile on the SEDAR+ website”

QP/CP Signedpositive

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: Brian McEwan, P.Geo., a Qualified Person as set out in National Instrument 43-101, reviewed and approved the technical information.

Evidence · text

“The technical information in this news release has been reviewed and approved by Brian McEwan, P.Geo., a Qualified Person as set out in National Instrument 43-101 - Standards of Disclosure for Mineral Projects.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

No Contained Metalnegative

Tonnage and grade reported but contained metal not calculated or disclosed — incomplete reporting.

Why it applies: contained_metal was not reported

PEA-Supportingneutral

Resource estimate prepared to support a Preliminary Economic Assessment — early-stage study.

Why it applies: the release names the study this estimate supports

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.