Abitibi Metals Intersects 3.72% CuEq over 9.2 m Within a Broader 1.25% CuEq over 60.2 m at the B26 Deposit

Original announcement by newsfile on

Company
Abitibi Metals Corp.
Ticker
AMQ
Exchange
Unavailable
Region
Québec
Primary commodity
Copper
Secondary commodities
Gold, Silver, Zinc
Document categories
Drill results
Extracted
2026-09-17 11:13:28 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Abitibi Metals Corp. announced new high-grade copper-gold intercepts from its B26 Polymetallic Deposit in Québec, with a highlight of 3.72% CuEq over 9.2 m within a broader 1.25% CuEq over 60.2 m. These results, among the strongest to date, demonstrate strong grade continuity and expand the deposit's known mineralization. The ongoing drill program aims to advance resource definition and conversion while extending the limits of the B26 system for a future resource update.

Reasoning: Abitibi Metals reports new high-grade copper-gold intercepts from its B26 Deposit, including 3.72% CuEq over 9.2 m within a broader 1.25% CuEq over 60.2 m. These results are among the strongest to date, demonstrating strong grade continuity and expanding the deposit's footprint, supporting future resource updates. QA/QC and metal equivalent assumptions are disclosed, and true widths are estimated.

Positive factors

  • High-grade copper-gold intercepts reported
  • Significant widths of mineralization
  • Extension of known mineralization (step-out drilling)
  • Resource definition and conversion drilling ongoing
  • Qualified Person (QP) signed off on technical information
  • QA/QC procedures disclosed
  • Metal equivalent assumptions clearly stated
  • Estimated true widths provided for intercepts

Negative factors

  • Compositing rules allow for internal dilution (up to three consecutive samples below cut-off)
  • Potential for volatilization of B, As, Hg during 4-acid digestion noted by lab

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 100

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole 1274-26-387-W2 returned 9.5% CuEq over 0.5m, and 1274-25-366-W1 returned 3.7% CuEq over 9.2m, which are exceptionally high grades for copper.

Evidence · table

“9.5”

Context: 1274-26-387-W2

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The 'Est true width (m)' column in Table 1 provides estimated true widths for all reported intercepts.

Evidence · table

“Est true width (m)”

Context: Drill hole ID

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The document includes a detailed 'QAQC' section outlining sample preparation, assay techniques, and quality control measures like blanks, replicates, duplicates, and standards.

Evidence · text

“QAQC The core logging and QAQC protocol program was run and supervised by the Company technical team. The drill core was split in half and sent to AGAT Laboratories Ltd.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Note 3 explicitly states the cut-off grades used for compositing main intervals (0.1% CuEq) and 'including' intervals (0.6% CuEq), and mentions allowing up to three consecutive samples below cut-off.

Evidence · text

“Note 3: Intervals are generally composited starting with a 0.1% CuEq cut-off and between 0.6% CuEq cut-off grade for the "including" intervals, allowing for up to three consecutive samples below cut-off grade.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The drilling program is described as 'further expanding the limits of the B26 system' and 'extends the known system eastward', indicating successful step-out drilling.

Evidence · text

“simultaneously advancing definition and resource conversion drilling as well as further expanding the limits of the B26 system that remain open.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The company states it is 'advancing definition and resource conversion drilling', which is characteristic of infill drilling to improve resource confidence.

Evidence · text

“simultaneously advancing definition and resource conversion drilling as well as further expanding the limits of the B26 system that remain open.”

QP/CP Signedpositive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: Louis Gariépy, P.Eng., VP Exploration of Abitibi Metals, is named as the Qualified Person responsible for the technical information in the release.

Evidence · text

“Information contained in this press release was reviewed and approved by Louis Gariépy, P.Eng. (OIQ #107538), VP Exploration of Abitibi Metals, who is a qualified person as defined under National Instrument 43-101”

Extracted facts

Stored fact records: 100. Some facts used in scoring do not have a stored record.

Drill Results (100)

1274-24-342-W1B26 Deposit · copperGrade: 2.5Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.5
Grade Unit
%
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Good copper equivalent grade based on spot prices
  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.6”

Context: 1274-24-342-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-24-342-W1B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.1”

Context: 1274-24-342-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-24-342-W1B26 Deposit · silverGrade: 2.7Grade Unit: g/tIntercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“2.7”

Context: 1274-24-342-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-24-342-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
1274-24-342-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2 m
True Width
1.2 m
From
1404.5 m
To
1406.5 m
Hole Depth
1609 m
Intercept Depth
1404.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-24-342-W1:1404.5-1406.5
Mining Method
underground

Location

Easting
652368
Northing
5513881
Elevation
272 m
Azimuth
215 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a polymetallic intercept.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: 1274-24-342-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 1.1Grade Unit: %Intercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.1
Grade Unit
%
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent, highlighting the strong value of the intercept.

Positive factors

  • Strong copper equivalent grade based on spot prices
  • Exceptional true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.3”

Context: 1274-25-366-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Exceptional true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.1”

Context: 1274-25-366-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 5Grade Unit: g/tIntercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
5
Grade Unit
g/t
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Exceptional true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“5.0”

Context: 1274-25-366-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 60.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
60.2 m
True Width
52.1 m
From
548.8 m
To
609 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-609
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Exceptional true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: 1274-25-366-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 0.7Grade Unit: %Intercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.7
Grade Unit
%
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Good copper equivalent grade based on spot prices
  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.2Grade Unit: g/tIntercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.2”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 5.8Grade Unit: g/tIntercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“5.8”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0.1Grade Unit: %Intercept: 25.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
25.2 m
True Width
21.8 m
From
548.8 m
To
574 m
Hole Depth
721 m
Intercept Depth
548.8 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:548.8-574
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The zinc grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low zinc grade

Evidence · table

“0.1”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 21.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 1.6Grade Unit: %Intercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.6
Grade Unit
%
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
562 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Strong copper equivalent grade based on spot prices
  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
562 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.3”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 9Grade Unit: g/tIntercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
9
Grade Unit
g/t
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
562 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“9.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0.1Grade Unit: %Intercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
4.4 m
True Width
3.8 m
From
562 m
To
566.4 m
Hole Depth
721 m
Intercept Depth
562 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:562-566.4
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The zinc grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low zinc grade

Evidence · table

“0.1”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 2.2Grade Unit: %Intercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.2
Grade Unit
%
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
580.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Strong copper equivalent grade based on spot prices
  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.5”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.2Grade Unit: g/tIntercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
580.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.2”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 6.9Grade Unit: g/tIntercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
6.9
Grade Unit
g/t
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
580.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“6.9”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 18.8 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
18.8 m
True Width
16.3 m
From
580.4 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
580.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:580.4-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · copperGrade: 3.4Grade Unit: %Intercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3.4
Grade Unit
%
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
590 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent, further highlighting the exceptional value of this intercept.

Positive factors

  • Exceptional copper equivalent grade based on spot prices
  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“3.9”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
590 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.3”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · silverGrade: 9.9Grade Unit: g/tIntercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
9.9
Grade Unit
g/t
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
590 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“9.9”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-366-W1B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 9.2 mView all details
Link to this fact

Identity

Hole ID
1274-25-366-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
9.2 m
True Width
8 m
From
590 m
To
599.2 m
Hole Depth
721 m
Intercept Depth
590 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-366-W1:590-599.2
Mining Method
underground

Location

Easting
653200
Northing
5513081
Elevation
269 m
Azimuth
347 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · copperGrade: 0.6Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.6
Grade Unit
%
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Good copper equivalent grade based on spot prices
  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept

Evidence · table

“1.2”

Context: 1274-25-368-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · goldGrade: 0.5Grade Unit: g/tIntercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade
  • Narrow intercept

Evidence · table

“0.5”

Context: 1274-25-368-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · silverGrade: 5.5Grade Unit: g/tIntercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade
  • Narrow intercept

Evidence · table

“5.5”

Context: 1274-25-368-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-25-368-W1B26 Deposit · zincGrade: 0.1Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1274-25-368-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
3.5 m
True Width
2.7 m
From
549 m
To
552.5 m
Hole Depth
750 m
Intercept Depth
549 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-25-368-W1:549-552.5
Mining Method
underground

Location

Easting
653348
Northing
5513092
Elevation
268 m
Azimuth
7 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The zinc grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low zinc grade
  • Narrow intercept

Evidence · table

“0.1”

Context: 1274-25-368-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 0.5Grade Unit: %Intercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
%
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing the overall value of the intercept.

Positive factors

  • Good copper equivalent grade based on spot prices
  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“0.7”

Context: 1274-26-378-W1A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.1”

Context: 1274-26-378-W1A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 1.9Grade Unit: g/tIntercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this wide intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“1.9”

Context: 1274-26-378-W1A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 40 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
40 m
True Width
30.6 m
From
966 m
To
1006 m
Hole Depth
1153 m
Intercept Depth
966 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:966-1006
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: 1274-26-378-W1A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 30.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 1.3Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.3
Grade Unit
%
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
970.2 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Good copper equivalent grade based on spot prices
  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.7”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
970.2 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.3”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 2.7Grade Unit: g/tIntercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
970.2 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“2.7”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
7.6 m
True Width
5.8 m
From
970.2 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
970.2 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:970.2-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 1.2Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.2
Grade Unit
%
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
975 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Good copper equivalent grade based on spot prices
  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept

Evidence · table

“1.8”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.5Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
975 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade
  • Narrow intercept

Evidence · table

“0.5”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 3Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3
Grade Unit
g/t
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
975 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade
  • Narrow intercept

Evidence · table

“3.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2.8 m
True Width
2.1 m
From
975 m
To
977.8 m
Hole Depth
1153 m
Intercept Depth
975 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:975-977.8
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.7
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade
  • Narrow intercept

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · copperGrade: 0.8Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.8
Grade Unit
%
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
982 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing the overall value of the intercept.

Positive factors

  • Good copper equivalent grade based on spot prices
  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
982 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.1”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · silverGrade: 2.5Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.5
Grade Unit
g/t
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
982 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“2.5”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W1AB26 Deposit · zincGrade: 0.2Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W1A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
7 m
True Width
5.4 m
From
982 m
To
989 m
Hole Depth
1153 m
Intercept Depth
982 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W1A:982-989
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The zinc grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low zinc grade

Evidence · table

“0.2”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · copperGrade: 1.4Grade Unit: %Intercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.4
Grade Unit
%
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Strong copper equivalent grade based on spot prices
  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“1.5”

Context: 1274-26-378-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.1”

Context: 1274-26-378-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · silverGrade: 2.6Grade Unit: g/tIntercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.6
Grade Unit
g/t
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“2.6”

Context: 1274-26-378-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 14.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
14.1 m
True Width
10 m
From
985.3 m
To
999.4 m
Hole Depth
1183 m
Intercept Depth
985.3 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:985.3-999.4
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Strong true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: 1274-26-378-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · copperGrade: 2.1Grade Unit: %Intercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.1
Grade Unit
%
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
989.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Strong copper equivalent grade based on spot prices
  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Evidence · table

“2.3”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
989.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade

Evidence · table

“0.1”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · silverGrade: 3.6Grade Unit: g/tIntercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3.6
Grade Unit
g/t
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
989.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade

Evidence · table

“3.6”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-378-W2B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 5.9 mView all details
Link to this fact

Identity

Hole ID
1274-26-378-W2
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
5.9 m
True Width
4.2 m
From
989.4 m
To
995.3 m
Hole Depth
1183 m
Intercept Depth
989.4 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-378-W2:989.4-995.3
Mining Method
underground

Location

Easting
652486
Northing
5512919
Elevation
272 m
Azimuth
2 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.2
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.6
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a significant polymetallic intercept.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · copperGrade: 0.2Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing a slightly higher value than the 2026 price deck equivalent.

Positive factors

  • Good copper equivalent grade based on spot prices
  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept

Evidence · table

“0.6”

Context: 1274-26-379A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · goldGrade: 0.3Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The gold grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low gold grade
  • Narrow intercept

Evidence · table

“0.3”

Context: 1274-26-379A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · silverGrade: 0.7Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.7
Grade Unit
g/t
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade
  • Narrow intercept

Evidence · table

“0.7”

Context: 1274-26-379A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-379AB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1274-26-379A
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
3.3 m
True Width
3 m
From
641.7 m
To
645 m
Hole Depth
735 m
Intercept Depth
641.7 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-379A:641.7-645
Mining Method
underground

Location

Easting
652071
Northing
5513116
Elevation
273 m
Azimuth
355 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a polymetallic intercept targeting a lower-grade zone.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade
  • Narrow intercept

Evidence · table

“0.0”

Context: 1274-26-379A

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This fact represents the copper equivalent grade calculated using spot prices for the interval, showing the overall value of the intercept.

Positive factors

  • Good copper equivalent grade based on spot prices
  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept

Evidence · table

“0.9”

Context: 1274-26-381

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This narrow intercept shows no gold, but is part of a polymetallic intercept targeting a lower-grade zone.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No gold grade
  • Narrow intercept

Evidence · table

“0.0”

Context: 1274-26-381

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · silverGrade: 7.7Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
7.7
Grade Unit
g/t
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this narrow intercept, but contributes to the overall polymetallic value.

Positive factors

  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade
  • Narrow intercept

Evidence · table

“7.7”

Context: 1274-26-381

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-381B26 Deposit · zincGrade: 3Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
1274-26-381
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3
Grade Unit
%
Intercept
2 m
True Width
1.5 m
From
633.5 m
To
635.5 m
Hole Depth
786 m
Intercept Depth
633.5 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-381:633.5-635.5
Mining Method
underground

Location

Easting
651989
Northing
5513116
Elevation
273 m
Azimuth
330 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.1
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This narrow intercept shows a moderate zinc grade, contributing to the overall polymetallic value.

Positive factors

  • Moderate zinc grade
  • True width estimated
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Narrow intercept

Evidence · table

“3.0”

Context: 1274-26-381

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · copperGrade: 0.3Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.3
Grade Unit
%
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Hole Depth
1435 m
Intercept Depth
1234 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

Location

Easting
651918
Northing
5512813
Elevation
277 m
Azimuth
350 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This intercept shows low copper grade, but confirms the continuation of the mineralizing system into the western part of the deposit.

Positive factors

  • Confirms fertile mineralizing system continues
  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low copper grade
  • Narrow intercept

Evidence · table

“0.3”

Context: 1274-26-386

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Hole Depth
1435 m
Intercept Depth
1234 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

Location

Easting
651918
Northing
5512813
Elevation
277 m
Azimuth
350 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no gold, but is part of a polymetallic intercept confirming the mineralizing system.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No gold grade
  • Narrow intercept

Evidence · table

“0.0”

Context: 1274-26-386

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · silverGrade: 2.7Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Hole Depth
1435 m
Intercept Depth
1234 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

Location

Easting
651918
Northing
5512813
Elevation
277 m
Azimuth
350 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: The silver grade is low for this intercept, but contributes to the overall polymetallic value.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • Low silver grade
  • Narrow intercept

Evidence · table

“2.7”

Context: 1274-26-386

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-386B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
1274-26-386
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
7 m
True Width
6.1 m
From
1234 m
To
1241 m
Hole Depth
1435 m
Intercept Depth
1234 m

Classification

Program
mixed
Sample Type
drill
Group ID
1274-26-386:1234-1241
Mining Method
underground

Location

Easting
651918
Northing
5512813
Elevation
277 m
Azimuth
350 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
% CuEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: This interval shows no zinc, but is part of a polymetallic intercept confirming the mineralizing system.

Positive factors

  • Good true width
  • QP signed
  • QA/QC disclosed
  • Metal equivalent assumptions disclosed

Negative factors

  • No zinc grade
  • Narrow intercept

Evidence · table

“0.0”

Context: 1274-26-386

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · copperGrade: 0.2Grade Unit: %Intercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.4 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · goldGrade: 0.7Grade Unit: g/tIntercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.7
Grade Unit
g/t
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.0 g/t·m is below.

Negative factors

  • 0.7 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.7”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · silverGrade: 0.6Grade Unit: g/tIntercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.3 g/t·m is below.

Negative factors

  • 0.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 7.2 mView all details
Link to this fact

Identity

Hole ID
1274-26-387
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
7.2 m
True Width
6.7 m
From
921.2 m
To
928.3 m
Intercept Depth
921.2 m

Classification

Sample Type
drill
Group ID
1274-26-387:921.2-928.3
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 0.9Grade Unit: %Intercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.9
Grade Unit
%
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.3 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.9”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 0.2Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.5 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 1.4Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.5 g/t·m is below.

Negative factors

  • 1.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.4”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
2.5 m
True Width
2.3 m
From
932.4 m
To
934.9 m
Intercept Depth
932.4 m

Classification

Sample Type
drill
Group ID
And:932.4-934.9
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · silverGrade: 41.1Grade Unit: g/tIntercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
41.1
Grade Unit
g/t
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 41.1 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 846.7 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“41.1”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · zincGrade: 1Grade Unit: %Intercept: 20.6 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1
Grade Unit
%
Intercept
20.6 m
True Width
17.8 m
From
859.9 m
To
880.5 m
Intercept Depth
859.9 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:859.9-880.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 20.6 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.0”

Context: 1274-26-387-W1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · silverGrade: 69.9Grade Unit: g/tIntercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
69.9
Grade Unit
g/t
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 69.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 775.9 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“69.9”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · zincGrade: 1.7Grade Unit: %Intercept: 11.1 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.7
Grade Unit
%
Intercept
11.1 m
True Width
9.6 m
From
863.5 m
To
874.6 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-874.6
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 18.9 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.7”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · copperGrade: 0Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · goldGrade: 0Grade Unit: g/tIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
g/t
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · silverGrade: 111.7Grade Unit: g/tIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
111.7
Grade Unit
g/t
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 111.7 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 502.7 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“111.7”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W1B26 Deposit · zincGrade: 3Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W1
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3
Grade Unit
%
Intercept
4.5 m
True Width
3.9 m
From
863.5 m
To
868 m
Intercept Depth
863.5 m

Classification

Sample Type
drill
Group ID
1274-26-387-W1:863.5-868
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 13.5 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.0”

Context: Including

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 0.1Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 0.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.1 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 19.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
19.4
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 19.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 9.7 g/t·m is below.

Negative factors

  • 19.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19.4”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 19.2Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
19.2
Grade Unit
%
Intercept
0.5 m
True Width
0.4 m
From
913.2 m
To
913.7 m
Intercept Depth
913.2 m

Classification

Sample Type
drill
Group ID
And:913.2-913.7
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 19.2 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 9.6 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 19.2 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19.2”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 0.2Grade Unit: %Intercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.2
Grade Unit
%
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.1 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 0.5Grade Unit: g/tIntercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.8 g/t·m is below.

Negative factors

  • 0.5 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 0.6Grade Unit: g/tIntercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 0.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
5.5 m
True Width
4.8 m
From
962 m
To
967.5 m
Intercept Depth
962 m

Classification

Sample Type
drill
Group ID
And:962-967.5
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · copperGrade: 2.3Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.3
Grade Unit
%
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.1 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.3 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.3”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · goldGrade: 8.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
8.1
Grade Unit
g/t
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 8.1 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 4.0 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 8.1 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.1”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · silverGrade: 2.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.4 g/t·m is below.

Negative factors

  • 2.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.9”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

1274-26-387-W2B26 Deposit · zincGrade: 0Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
1274-26-387-W2
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
0.5 m
True Width
0.3 m
From
990.6 m
To
991.1 m
Intercept Depth
990.6 m

Classification

Sample Type
drill
Group ID
1274-26-387-W2:990.6-991.1
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: 1274-26-387-W2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · copperGrade: 2.8Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
copper
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
2.8
Grade Unit
%
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 5.0 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 2.8 % copper is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.8”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · goldGrade: 1.6Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
gold
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
1.6
Grade Unit
g/t
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.9 g/t·m is below.

Negative factors

  • 1.6 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.6”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · silverGrade: 3.4Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
silver
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
3.4
Grade Unit
g/t
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.1 g/t·m is below.

Negative factors

  • 3.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.4”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

AndB26 Deposit · zincGrade: 0Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
And
Project
B26 Deposit
Commodity
zinc
Region
canada_qc
Reported Region
canada_qc
Ticker
AMQ

Geometry

Grade
0
Grade Unit
%
Intercept
1.8 m
True Width
1.2 m
From
998.4 m
To
1000.2 m
Intercept Depth
998.4 m

Classification

Sample Type
drill
Group ID
And:998.4-1000.2
Mining Method
underground

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "It targeted a zone on the eastern side of the deposit and delivered materially higher-grade results than anticipated, in"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.