Arizona Gold & Silver Drills Multiple Higher Grade Gold Intervals within Significantly Wider Mineralized Structure - 76.5 Metres at 2.36 gpt Gold and 16.24 gpt Silver Beginning at 265.8 Metres on the Philadelphia Project, Arizona

Original announcement by tmx on

Company
Arizona Gold & Silver Inc.
Ticker
AZS
Exchange
TSX
Region
Arizona
Primary commodity
Gold
Secondary commodities
Silver
Document categories
Drill results
Extracted
2026-09-19 12:44:13 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Arizona Gold & Silver Inc. reported significant drill results from hole PC25-157 at the Philadelphia Project, featuring a 76.5m wide interval at 2.36 g/t gold and 16.24 g/t silver. The results highlight a widening mineralized structure due to new stockwork mineralization in the hanging wall, increasing the potential for bulk-mining.

Reasoning: Strong drill results showing both high-grade intercepts and significant structural widening, suggesting a larger-than-expected mineralized corridor.

Positive factors

  • Significant width of mineralized structure (76.5m)
  • Discovery of new stockwork mineralization in hanging wall
  • Potential for bulk-mining component
  • High-grade sub-intervals (up to 13.8 g/t Au)

Facts used in scoring: 8

Classification and evidence

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: Hole PC25-157 is located 50m north of the previous high-grade intercept in PC25-156, showing continued mineralization.

Evidence · text

“Hole located 50 metres (“m”) north of high-grade intercept in PC25-156”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release details laboratory (Skyline Labs), assay methods (fire assay, 4-acid digestion), and QP sign-off.

Evidence · text

“delivered in its entirety to Skyline Labs in Tucson, Arizona where it was sawed in half”

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The document provides an estimate for the true thickness of the intercepts.

Evidence · text

“True thickness of the above intercepts is estimated at 63% of drilled thickness.”

Extracted facts

Stored fact records: 8. Some facts used in scoring do not have a stored record.

Drill Results (8)

PC25-157Philadelphia · goldGrade: 2.36Grade Unit: g/tIntercept: 76.52 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
gold
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
2.36
Grade Unit
g/t
Intercept
76.52 m
True Width
48.2 m
From
265.85 m
To
342.38 m
Hole Depth
374.08 m
Intercept Depth
265.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
PC25-157:265.85-342.38
Mining Method
underground

Location

Location
Perry vein
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Wide intercept with respectable grade.

Positive factors

  • Significant width

Evidence · table

“2.36”

Context: 76.52

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 48.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · silverGrade: 16.24Grade Unit: g/tIntercept: 76.52 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
silver
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
16.24
Grade Unit
g/t
Intercept
76.52 m
True Width
48.2 m
From
265.85 m
To
342.38 m
Hole Depth
374.08 m
Intercept Depth
265.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
PC25-157:265.85-342.38
Mining Method
underground

Location

Location
Perry vein
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Silver byproduct in a gold-focused intercept.

Evidence · table

“16.24”

Context: 76.52

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 48.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · goldGrade: 7.02Grade Unit: g/tIntercept: 6.28 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
gold
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
7.02
Grade Unit
g/t
Intercept
6.28 m
From
268.9 m
To
275.18 m
Hole Depth
374.08 m
Intercept Depth
265.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
PC25-157:268.9-275.18
Mining Method
underground

Location

Location
Perry vein
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Strong high-grade sub-interval.

Positive factors

  • High grade

Evidence · table

“7.02”

Context: 6.28

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · goldGrade: 13.8Grade Unit: g/tIntercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
gold
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
13.8
Grade Unit
g/t
Intercept
1.52 m
From
284.54 m
To
286.07 m
Hole Depth
374.08 m
Intercept Depth
265.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
PC25-157:284.54-286.07
Mining Method
underground

Location

Location
Perry vein
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Very high grade intercept.

Positive factors

  • Bonanza grade

Evidence · table

“13.80”

Context: 1.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · goldGrade: 8.32Grade Unit: g/tIntercept: 3.35 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
gold
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
8.32
Grade Unit
g/t
Intercept
3.35 m
From
335.98 m
To
339.33 m
Hole Depth
374.08 m
Intercept Depth
265.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
PC25-157:335.98-339.33
Mining Method
underground

Location

Location
Perry vein
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Strong high-grade sub-interval.

Positive factors

  • High grade

Evidence · table

“8.32”

Context: 3.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · silverGrade: 13.93Grade Unit: g/tIntercept: 6.28 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
silver
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
13.93
Grade Unit
g/t
Intercept
6.28 m
From
268.9 m
To
275.18 m
Intercept Depth
268.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
PC25-157:268.9-275.18
Mining Method
underground

Location

Location
Perry vein
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Expanded from assay table. 13.93 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 87.5 g/t·m is below.

Negative factors

  • 13.93 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.93”

Context: Summary Assay Results for Core Hole PC25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · silverGrade: 39.7Grade Unit: g/tIntercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
silver
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
39.7
Grade Unit
g/t
Intercept
1.52 m
From
284.54 m
To
286.07 m
Intercept Depth
284.54 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
PC25-157:284.54-286.07
Mining Method
underground

Location

Location
Perry vein
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Expanded from assay table. 39.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 60.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“39.70”

Context: Summary Assay Results for Core Hole PC25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

PC25-157Philadelphia · silverGrade: 37.12Grade Unit: g/tIntercept: 3.35 mView all details
Link to this fact

Identity

Hole ID
PC25-157
Project
Philadelphia
Commodity
silver
Region
usa_az
Reported Region
usa_az
Ticker
AZS

Geometry

Grade
37.12
Grade Unit
g/t
Intercept
3.35 m
From
335.98 m
To
339.33 m
Intercept Depth
335.98 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
PC25-157:335.98-339.33
Mining Method
underground

Location

Location
Perry vein
Loc. Source
document

QA/QC

Laboratory
Skyline Labs
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
fire assay, four-acid digestion, ICP analysis

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-08T00:00:00.000Z

Reasoning: Expanded from assay table. 37.12 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 124.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“37.12”

Context: Summary Assay Results for Core Hole PC25

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.