# Bullion Gold lance des programmes d'exploration de surface aux projets BODO et Langlade

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d

Original source: https://www.newsfilecorp.com/release/314520/Bullion-Gold-lance-des-programmes-dexploration-de-surface-aux-projets-BODO-et-Langlade

Publisher: newsfile

Original announcement: 2026-09-16T11:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Bullion Gold Discoveries Corp.

- Ticker: BGD

- Exchange: Unavailable

- Region: Quebec

- Primary commodity: Copper

- Secondary commodities: Zinc, Gold, Silver, Cobalt

- Document categories: Drill results, Other

- Extracted: 2026-09-16 11:20:30 UTC

Narrative sentiment: 0.40 · Bullish

## Minestarters Atlas summary

Bullion Gold Discoveries Corp. has launched surface exploration programs at its BODO and Langlade projects in Quebec. The company reported drill results from the Langlade project, with notable intercepts including 4.0 m at 0.60% Cu, 1.10% Zn, 0.06 g/t Au, and 14.35 g/t Ag \(1.22% CuEq\) in hole LAN-26-29, and 0.5 m at 0.81% Cu, 0.75% Zn, 0.56 g/t Au, and 36.10 g/t Ag \(2.32% CuEq\) in hole LAN-26-30. Additionally, high-grade surface samples were collected from the BODO project, with one sample returning 15.20% Cu, 2.53 g/t Au, 137.00 g/t Ag, and 577 ppm Co.

Reasoning: Bullion Gold Discoveries Corp. announced new drill results from its Langlade project, revealing several significant polymetallic intercepts, including high-grade sub-intervals. Concurrently, high-grade surface samples were reported from the BODO project. The company provided detailed QA/QC disclosure and a Qualified Person's sign-off, enhancing confidence. However, some drill holes were barren, and the true width of intercepts is an estimate, which introduces some uncertainty.

- Positive factor: Significant drill intercepts with high-grade sub-intervals reported from Langlade project

- Positive factor: High-grade polymetallic surface samples from BODO project

- Positive factor: QA/QC procedures disclosed, including use of AGAT laboratories and insertion of blanks, standards, and duplicates

- Positive factor: Technical information approved by a Qualified Person \(QP\)

- Positive factor: Metal equivalent assumptions are transparently disclosed

- Negative factor: Some drill holes returned no significant assay results

- Negative factor: True width of drill intercepts is an estimate, not precisely measured

- Negative factor: Surface samples inherently carry lower confidence than drill results

Facts used in scoring: 112

## Classification and evidence

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: The release details QA/QC procedures including the use of AGAT laboratories, pyroanalysis, ICP-OES, and insertion of duplicates, standards, and blanks.

Evidence · text

> Les carottes ont été coupées en deux, et l'une des moitiés a été envoyée aux laboratoires AGAT, à Val-d'Or, pour analyse. L'or a été analysé par pyroanalyse \(50 g\) avec finition par absorption atomique, tandis que les métaux de base ont été analysés par digestion à quatre acides avec finition ICP-OES. ... Des duplicatas de préparation d'échantillons, des étalons de référence certifiés et des blancs sont insérés dans le flux d'échantillons.

**QP/CP Signed**

Polarity: positive

Story-specific tag

Definition: Qualified Person \(QP\) or Competent Person \(CP\) named and signed off — a member of a recognized professional association \(e.g., AusIMM, SME, AIG, P.Geo\) with relevant experience.

Why it applies: Mme Suzie Tremblay, a member of the Ordre des géologues du Québec, is named as the Qualified Person responsible for reviewing and approving the technical information.

Evidence · text

> L'information scientifique et technique divulguée dans ce communiqué a été examinée et approuvée par Mme Suzie Tremblay, membre en exercice de l'Ordre des géologues du Québec \(OGQ n° 10664\), qui est une « personne qualifiée » au sens du Règlement 43-101 sur l'information concernant les projets miniers.

**Step-Out Extension**

Polarity: positive

Definition: Mineralization extended beyond the previously known limit.

Why it applies: The drill program at Langlade aimed for a potential extension of mineralization.

Evidence · text

> Le programme visait un secteur prometteur pour une extension potentielle de la minéralisation.

**True Width Estimated**

Polarity: neutral

Story-specific tag

Definition: No canonical definition is currently available.

Why it applies: The document states that true width is estimated at 80-85% of core length, rather than precisely measured or calculated.

Evidence · table

> L'épaisseur vraie est estimée à environ 80-85 % de la longueur des carottes, en fonction des angles de déviation.

Context: Les largeurs indiquées correspondent à la longueur des carottes.

## Extracted facts

Stored fact records: 112. Some facts used in scoring do not have a stored record.

## Drill Results (112)

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-0)

Langlade · copper

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 37.9 m
- True Width: 31.2675 m
- From: 107.6 m
- To: 145.5 m
- Intercept Depth: 107.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:107.6-145.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows moderate copper equivalent grades over a significant length, but the individual copper grade is below the weak threshold for VMS deposits.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Copper grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,21

Context: 37,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 31.2675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-1)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 37.9 m
- True Width: 31.2675 m
- From: 107.6 m
- To: 145.5 m
- Intercept Depth: 107.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:107.6-145.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a zinc grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,22

Context: 37,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 31.2675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-2)

Langlade · gold

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 37.9 m
- True Width: 31.2675 m
- From: 107.6 m
- To: 145.5 m
- Intercept Depth: 107.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:107.6-145.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a gold grade below the weak threshold, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,05

Context: 37,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 31.2675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-3)

Langlade · silver

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 7.38
- Grade Unit: g/t
- Intercept: 37.9 m
- True Width: 31.2675 m
- From: 107.6 m
- To: 145.5 m
- Intercept Depth: 107.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:107.6-145.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.45
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a silver grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 7,38

Context: 37,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 31.2675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-4)

Langlade · copper

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 4 m
- True Width: 3.3 m
- From: 114 m
- To: 118 m
- Intercept Depth: 114 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:114-118
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This sub-interval shows strong copper equivalent grades and moderate copper grades over a narrow width, indicating a higher-grade zone within the broader intercept.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,60

Context: 4,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.3

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-5)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 4 m
- True Width: 3.3 m
- From: 114 m
- To: 118 m
- Intercept Depth: 114 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:114-118
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This sub-interval shows a zinc grade below the weak threshold for VMS deposits over a narrow width.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 1,10

Context: 4,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.3

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-6)

Langlade · gold

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.06
- Grade Unit: g/t
- Intercept: 4 m
- True Width: 3.3 m
- From: 114 m
- To: 118 m
- Intercept Depth: 114 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:114-118
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This sub-interval shows a gold grade below the weak threshold over a narrow width.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,06

Context: 4,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.3

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-7)

Langlade · silver

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 14.35
- Grade Unit: g/t
- Intercept: 4 m
- True Width: 3.3 m
- From: 114 m
- To: 118 m
- Intercept Depth: 114 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:114-118
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This sub-interval shows a silver grade below the weak threshold for VMS deposits over a narrow width.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 14,35

Context: 4,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.3

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-8)

Langlade · copper

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.75
- Grade Unit: %
- Intercept: 1 m
- True Width: 0.825 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:120-121
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.19
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and moderate copper grades, indicating a high-grade veinlet.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,75

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-9)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 1 m
- True Width: 0.825 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:120-121
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.19
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,22

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-10)

Langlade · gold

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 1 m
- True Width: 0.825 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:120-121
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.19
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,05

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-11)

Langlade · silver

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 17.6
- Grade Unit: g/t
- Intercept: 1 m
- True Width: 0.825 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:120-121
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.19
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 17,60

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-12)

Langlade · copper

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.72
- Grade Unit: %
- Intercept: 1 m
- True Width: 0.825 m
- From: 122 m
- To: 123 m
- Intercept Depth: 122 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:122-123
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and moderate copper grades, indicating a high-grade veinlet.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,72

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-13)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- True Width: 0.825 m
- From: 122 m
- To: 123 m
- Intercept Depth: 122 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:122-123
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,14

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-14)

Langlade · gold

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- True Width: 0.825 m
- From: 122 m
- To: 123 m
- Intercept Depth: 122 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:122-123
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,01

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-15)

Langlade · silver

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 24.6
- Grade Unit: g/t
- Intercept: 1 m
- True Width: 0.825 m
- From: 122 m
- To: 123 m
- Intercept Depth: 122 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:122-123
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.22
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 24,60

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-16)

Langlade · copper

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.96
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:136-136.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and moderate copper grades, indicating a high-grade veinlet.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,96

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-17)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:136-136.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,09

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-18)

Langlade · gold

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.12
- Grade Unit: g/t
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:136-136.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,12

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-19)

Langlade · silver

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 14.8
- Grade Unit: g/t
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:136-136.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 14,80

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-20)

Langlade · copper

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 3 m
- True Width: 2.475 m
- From: 139.5 m
- To: 142.5 m
- Intercept Depth: 139.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:139.5-142.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.82
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows moderate copper equivalent grades, but individual metal grades are low.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Copper grade is below weak for VMS deposit type

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,18

Context: 3,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.475

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-21)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 3 m
- True Width: 2.475 m
- From: 139.5 m
- To: 142.5 m
- Intercept Depth: 139.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:139.5-142.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.82
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,08

Context: 3,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.475

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-22)

Langlade · gold

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.14
- Grade Unit: g/t
- Intercept: 3 m
- True Width: 2.475 m
- From: 139.5 m
- To: 142.5 m
- Intercept Depth: 139.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:139.5-142.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.82
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,14

Context: 3,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.475

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-29

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-23)

Langlade · silver

#### Identity

- Hole ID: LAN-26-29
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 24.55
- Grade Unit: g/t
- Intercept: 3 m
- True Width: 2.475 m
- From: 139.5 m
- To: 142.5 m
- Intercept Depth: 139.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-29:139.5-142.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.82
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 24,55

Context: 3,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.475

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-24)

Langlade · copper

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 6.5 m
- True Width: 5.3625 m
- From: 98.5 m
- To: 105 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:98.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows moderate copper equivalent grades over a moderate length, with individual copper grades also moderate, but other metals are low.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Copper grade is moderate for VMS deposit type

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,35

Context: 6,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.3625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-25)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.37
- Grade Unit: %
- Intercept: 6.5 m
- True Width: 5.3625 m
- From: 98.5 m
- To: 105 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:98.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows a zinc grade below the weak threshold for VMS deposits over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,37

Context: 6,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.3625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-26)

Langlade · gold

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.09
- Grade Unit: g/t
- Intercept: 6.5 m
- True Width: 5.3625 m
- From: 98.5 m
- To: 105 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:98.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows a gold grade below the weak threshold over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,09

Context: 6,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.3625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-27)

Langlade · silver

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 13.16
- Grade Unit: g/t
- Intercept: 6.5 m
- True Width: 5.3625 m
- From: 98.5 m
- To: 105 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:98.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows a silver grade below the weak threshold for VMS deposits over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 13,16

Context: 6,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.3625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-28)

Langlade · copper

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.81
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:99-99.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 2.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and moderate copper grades, along with weak gold and silver, indicating a high-grade veinlet.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Weak gold grade

- Positive factor: Weak silver grade

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,81

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-29)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.75
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:99-99.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 2.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,75

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-30)

Langlade · gold

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.56
- Grade Unit: g/t
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:99-99.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 2.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a weak gold grade.

- Positive factor: Weak gold grade

- Positive factor: True width estimated

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,56

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-31)

Langlade · silver

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 36.1
- Grade Unit: g/t
- Intercept: 0.5 m
- True Width: 0.4125 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:99-99.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 2.32
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a weak silver grade for VMS deposits.

- Positive factor: Weak silver grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 36,10

Context: 0,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4125

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-32)

Langlade · copper

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.54
- Grade Unit: %
- Intercept: 2.5 m
- True Width: 2.0625 m
- From: 102.5 m
- To: 105 m
- Intercept Depth: 102.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:102.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.16
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows strong copper equivalent grades and moderate copper grades, indicating a higher-grade zone.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,54

Context: 2,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.0625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-33)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.51
- Grade Unit: %
- Intercept: 2.5 m
- True Width: 2.0625 m
- From: 102.5 m
- To: 105 m
- Intercept Depth: 102.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:102.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.16
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,51

Context: 2,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.0625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-34)

Langlade · gold

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 2.5 m
- True Width: 2.0625 m
- From: 102.5 m
- To: 105 m
- Intercept Depth: 102.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:102.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.16
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,10

Context: 2,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.0625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-30

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-35)

Langlade · silver

#### Identity

- Hole ID: LAN-26-30
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 19.9
- Grade Unit: g/t
- Intercept: 2.5 m
- True Width: 2.0625 m
- From: 102.5 m
- To: 105 m
- Intercept Depth: 102.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-30:102.5-105
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.16
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 19,90

Context: 2,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.0625

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-36)

Langlade · copper

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 21.9 m
- True Width: 18.0675 m
- From: 64.5 m
- To: 86.4 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:64.5-86.4
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows moderate copper equivalent grades over a significant length, but individual metal grades are low.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Copper grade is below weak for VMS deposit type

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,20

Context: 21,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.0675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-37)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 21.9 m
- True Width: 18.0675 m
- From: 64.5 m
- To: 86.4 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:64.5-86.4
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a zinc grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,30

Context: 21,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.0675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-38)

Langlade · gold

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 21.9 m
- True Width: 18.0675 m
- From: 64.5 m
- To: 86.4 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:64.5-86.4
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a gold grade below the weak threshold, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,05

Context: 21,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.0675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-39)

Langlade · silver

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 4.68
- Grade Unit: g/t
- Intercept: 21.9 m
- True Width: 18.0675 m
- From: 64.5 m
- To: 86.4 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:64.5-86.4
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.42
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a silver grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 4,68

Context: 21,9

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.0675

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-40)

Langlade · copper

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 66 m
- To: 67.2 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:66-67.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.15
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and weak copper grades, indicating a higher-grade zone.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Weak copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,29

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-41)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 2.35
- Grade Unit: %
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 66 m
- To: 67.2 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:66-67.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.15
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a weak zinc grade for VMS deposits.

- Positive factor: Weak zinc grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 2,35

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-42)

Langlade · gold

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 66 m
- To: 67.2 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:66-67.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.15
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,05

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-43)

Langlade · silver

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 10.7
- Grade Unit: g/t
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 66 m
- To: 67.2 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:66-67.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.15
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 10,70

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-44)

Langlade · copper

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.64
- Grade Unit: %
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 70 m
- To: 71.2 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:70-71.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.35
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and moderate copper grades, indicating a higher-grade zone.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,64

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-45)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 1.16
- Grade Unit: %
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 70 m
- To: 71.2 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:70-71.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.35
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 1,16

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-46)

Langlade · gold

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 70 m
- To: 71.2 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:70-71.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.35
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,03

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-31

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-47)

Langlade · silver

#### Identity

- Hole ID: LAN-26-31
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 13.5
- Grade Unit: g/t
- Intercept: 1.2 m
- True Width: 0.99 m
- From: 70 m
- To: 71.2 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-31:70-71.2
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.35
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 13,50

Context: 1,2

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.99

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-48)

Langlade · copper

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 5.5 m
- True Width: 4.5375 m
- From: 64.5 m
- To: 80 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-80
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.27
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows low copper equivalent grades and individual metal grades below the weak threshold over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Copper grade is below weak for VMS deposit type

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,12

Context: 5,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.5375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-49)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 5.5 m
- True Width: 4.5375 m
- From: 64.5 m
- To: 80 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-80
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.27
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows a zinc grade below the weak threshold for VMS deposits over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,14

Context: 5,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.5375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-50)

Langlade · gold

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 5.5 m
- True Width: 4.5375 m
- From: 64.5 m
- To: 80 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-80
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.27
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows a gold grade below the weak threshold over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,03

Context: 5,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.5375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-51)

Langlade · silver

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 5.5 m
- True Width: 4.5375 m
- From: 64.5 m
- To: 80 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-80
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.27
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This intercept shows a silver grade below the weak threshold for VMS deposits over a moderate length.

- Positive factor: Moderate intercept length

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 4,00

Context: 5,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.5375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-52)

Langlade · copper

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 1.15
- Grade Unit: %
- Intercept: 0.8 m
- True Width: 0.66 m
- From: 64.5 m
- To: 65.3 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-65.3
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.92
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and strong copper grades, along with weak silver, indicating a high-grade veinlet.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Weak silver grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc and gold grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 1,15

Context: 0,8

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.66

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-53)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 0.8 m
- True Width: 0.66 m
- From: 64.5 m
- To: 65.3 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-65.3
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.92
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,18

Context: 0,8

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.66

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-54)

Langlade · gold

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.08
- Grade Unit: g/t
- Intercept: 0.8 m
- True Width: 0.66 m
- From: 64.5 m
- To: 65.3 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-65.3
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.92
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,08

Context: 0,8

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.66

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-55)

Langlade · silver

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 34.4
- Grade Unit: g/t
- Intercept: 0.8 m
- True Width: 0.66 m
- From: 64.5 m
- To: 65.3 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:64.5-65.3
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.92
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a weak silver grade for VMS deposits.

- Positive factor: Weak silver grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 34,4

Context: 0,8

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.66

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-56)

Langlade · copper

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 11.5 m
- True Width: 9.4875 m
- From: 91 m
- To: 102.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:91-102.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.33
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows moderate copper equivalent grades over a significant length, but individual metal grades are low.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Copper grade is below weak for VMS deposit type

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,16

Context: 11,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.4875

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-57)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 11.5 m
- True Width: 9.4875 m
- From: 91 m
- To: 102.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:91-102.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.33
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a zinc grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,12

Context: 11,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.4875

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-58)

Langlade · gold

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.07
- Grade Unit: g/t
- Intercept: 11.5 m
- True Width: 9.4875 m
- From: 91 m
- To: 102.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:91-102.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.33
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a gold grade below the weak threshold, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,07

Context: 11,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.4875

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-59)

Langlade · silver

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 2.92
- Grade Unit: g/t
- Intercept: 11.5 m
- True Width: 9.4875 m
- From: 91 m
- To: 102.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:91-102.5
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.33
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a silver grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 2,92

Context: 11,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.4875

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-60)

Langlade · copper

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.48
- Grade Unit: %
- Intercept: 1 m
- True Width: 0.825 m
- From: 93 m
- To: 94 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:93-94
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows moderate copper equivalent grades and weak copper grades, indicating a higher-grade zone.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Weak copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,48

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-61)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.58
- Grade Unit: %
- Intercept: 1 m
- True Width: 0.825 m
- From: 93 m
- To: 94 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:93-94
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,58

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-62)

Langlade · gold

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 1 m
- True Width: 0.825 m
- From: 93 m
- To: 94 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:93-94
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,10

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-32

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-63)

Langlade · silver

#### Identity

- Hole ID: LAN-26-32
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 7.4
- Grade Unit: g/t
- Intercept: 1 m
- True Width: 0.825 m
- From: 93 m
- To: 94 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-32:93-94
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.89
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 7,40

Context: 1,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.825

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-64)

Langlade · copper

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 22 m
- True Width: 18.15 m
- From: 68 m
- To: 90 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:68-90
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows moderate copper equivalent grades over a significant length, but individual metal grades are low.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Copper grade is below weak for VMS deposit type

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,20

Context: 22,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.15

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-65)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 22 m
- True Width: 18.15 m
- From: 68 m
- To: 90 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:68-90
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a zinc grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,15

Context: 22,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.15

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-66)

Langlade · gold

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.06
- Grade Unit: g/t
- Intercept: 22 m
- True Width: 18.15 m
- From: 68 m
- To: 90 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:68-90
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a gold grade below the weak threshold, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,06

Context: 22,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.15

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-67)

Langlade · silver

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 5.05
- Grade Unit: g/t
- Intercept: 22 m
- True Width: 18.15 m
- From: 68 m
- To: 90 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:68-90
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.41
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This broad intercept shows a silver grade below the weak threshold for VMS deposits, despite the significant length.

- Positive factor: Strong intercept length

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 5,05

Context: 22,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 18.15

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-68)

Langlade · copper

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 2 m
- True Width: 1.65 m
- From: 73.6 m
- To: 75.6 m
- Intercept Depth: 73.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:73.6-75.6
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.85
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows moderate copper equivalent grades and weak copper grades, indicating a higher-grade zone.

- Positive factor: Moderate copper equivalent grade for VMS deposit type

- Positive factor: Weak copper grade for VMS deposit type

- Positive factor: True width estimated

- Negative factor: Zinc, gold, and silver grades are weak or below weak

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,49

Context: 2,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-69)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 2 m
- True Width: 1.65 m
- From: 73.6 m
- To: 75.6 m
- Intercept Depth: 73.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:73.6-75.6
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.85
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,26

Context: 2,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-70)

Langlade · gold

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 2 m
- True Width: 1.65 m
- From: 73.6 m
- To: 75.6 m
- Intercept Depth: 73.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:73.6-75.6
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.85
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a gold grade below the weak threshold.

- Positive factor: True width estimated

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,05

Context: 2,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-71)

Langlade · silver

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 11.97
- Grade Unit: g/t
- Intercept: 2 m
- True Width: 1.65 m
- From: 73.6 m
- To: 75.6 m
- Intercept Depth: 73.6 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:73.6-75.6
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 0.85
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 11,97

Context: 2,0

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-72)

Langlade · copper

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: copper
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2375 m
- From: 85.5 m
- To: 87 m
- Intercept Depth: 85.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:85.5-87
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.02
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows strong copper equivalent grades and weak copper and gold grades, indicating a higher-grade zone.

- Positive factor: Strong copper equivalent grade for VMS deposit type

- Positive factor: Weak copper grade for VMS deposit type

- Positive factor: Weak gold grade

- Positive factor: True width estimated

- Negative factor: Zinc and silver grades are weak or below weak

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,34

Context: 1,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-73)

Langlade · zinc

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: zinc
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2375 m
- From: 85.5 m
- To: 87 m
- Intercept Depth: 85.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:85.5-87
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.02
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a zinc grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Zinc grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,11

Context: 1,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-74)

Langlade · gold

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: gold
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 0.46
- Grade Unit: g/t
- Intercept: 1.5 m
- True Width: 1.2375 m
- From: 85.5 m
- To: 87 m
- Intercept Depth: 85.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:85.5-87
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.02
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a weak gold grade.

- Positive factor: Weak gold grade

- Positive factor: True width estimated

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 0,46

Context: 1,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### LAN-26-33

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-75)

Langlade · silver

#### Identity

- Hole ID: LAN-26-33
- Project: Langlade
- Commodity: silver
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: BGD

#### Geometry

- Grade: 6.7
- Grade Unit: g/t
- Intercept: 1.5 m
- True Width: 1.2375 m
- From: 85.5 m
- To: 87 m
- Intercept Depth: 85.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: LAN-26-33:85.5-87
- Mining Method: unknown

#### QA/QC

- Laboratory: AGAT
- QP Signed: Yes
- QA/QC Methods: blanks, standards, duplicates, check\_assays

#### Metal Equivalent

- Metal Eq. Grade: 1.02
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This very narrow sub-interval shows a silver grade below the weak threshold for VMS deposits.

- Positive factor: True width estimated

- Negative factor: Silver grade is below weak for VMS deposit type

- Negative factor: Very narrow intercept length

- Negative factor: Apparent width only \(true width is an estimate\)

Evidence · table

> 6,70

Context: 1,5

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2375

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 77

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-76)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 6.85
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned an exceptional gold grade, indicating high-grade mineralization at surface.

- Positive factor: Exceptional gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 6,85

Context: F671605

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 78

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-77)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 63
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak silver grade.

- Positive factor: Weak silver grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 63,00

Context: F671605

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 79

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-78)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 2.82
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned an exceptional copper grade, indicating high-grade mineralization at surface.

- Positive factor: Exceptional copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 2,82

Context: F671605

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 80

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-79)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0116
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 116

Context: F671605

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 81

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-80)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 4.14
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak gold grade.

- Positive factor: Weak gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 4,14

Context: F671606

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 82

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-81)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 1.3
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a silver grade below the weak threshold.

- Negative factor: Silver grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 1,30

Context: F671606

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 83

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-82)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.01
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a copper grade below the weak threshold.

- Negative factor: Copper grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 0,01

Context: F671606

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 84

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-83)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0028
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 28

Context: F671606

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 85

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-84)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.65
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak gold grade.

- Positive factor: Weak gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 0,65

Context: F671613

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 86

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-85)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 11
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a silver grade below the weak threshold.

- Negative factor: Silver grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 11,00

Context: F671613

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 87

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-86)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 1.38
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a strong copper grade.

- Positive factor: Strong copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 1,38

Context: F671613

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 88

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-87)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0061
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 61

Context: F671613

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 89

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-88)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.28
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a gold grade below the weak threshold.

- Negative factor: Gold grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 0,28

Context: F671616

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 90

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-89)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 16.1
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a silver grade below the weak threshold.

- Negative factor: Silver grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 16,10

Context: F671616

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 91

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-90)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 2.21
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a strong copper grade.

- Positive factor: Strong copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 2,21

Context: F671616

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 92

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-91)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0072
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 72

Context: F671616

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 93

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-92)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 2.53
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a strong gold grade.

- Positive factor: Strong gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 2,53

Context: F671617

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 94

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-93)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 137
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a moderate silver grade.

- Positive factor: Moderate silver grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 137,00

Context: F671617

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 95

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-94)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 15.2
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned an exceptional copper grade, indicating very high-grade mineralization at surface.

- Positive factor: Exceptional copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 15,20

Context: F671617

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 96

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-95)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0577
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 577

Context: F671617

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 97

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-96)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 4.17
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak gold grade.

- Positive factor: Weak gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 4,17

Context: F671703

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 98

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-97)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 5.9
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a silver grade below the weak threshold.

- Negative factor: Silver grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 5,90

Context: F671703

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 99

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-98)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.24
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a copper grade below the weak threshold.

- Negative factor: Copper grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 0,24

Context: F671703

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 100

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-99)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0052
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 52

Context: F671703

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 101

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-100)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.58
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak gold grade.

- Positive factor: Weak gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 0,58

Context: F671707

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 102

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-101)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 69.4
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak silver grade.

- Positive factor: Weak silver grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 69,40

Context: F671707

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 103

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-102)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 3.96
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned an exceptional copper grade, indicating high-grade mineralization at surface.

- Positive factor: Exceptional copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 3,96

Context: F671707

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 104

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-103)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0215
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 215

Context: F671707

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 105

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-104)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 1.16
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a moderate gold grade.

- Positive factor: Moderate gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 1,16

Context: F671713

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 106

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-105)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 66
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak silver grade.

- Positive factor: Weak silver grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 66,00

Context: F671713

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 107

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-106)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 3.22
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned an exceptional copper grade, indicating high-grade mineralization at surface.

- Positive factor: Exceptional copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 3,22

Context: F671713

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 108

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-107)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.0007
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 7

Context: F671713

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 109

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-108)

BODO · gold

#### Identity

- Project: BODO
- Commodity: gold
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 2.2
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a strong gold grade.

- Positive factor: Strong gold grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 2,20

Context: F671714

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 110

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-109)

BODO · silver

#### Identity

- Project: BODO
- Commodity: silver
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 62.4
- Grade Unit: g/t

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a weak silver grade.

- Positive factor: Weak silver grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 62,40

Context: F671714

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 111

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-110)

BODO · copper

#### Identity

- Project: BODO
- Commodity: copper
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 6.83
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned an exceptional copper grade, indicating very high-grade mineralization at surface.

- Positive factor: Exceptional copper grade for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 6,83

Context: F671714

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Fact 112

[Link to this fact](https://atlas-extractions.minestarters.com/news/bullion-gold-lance-des-programmes-d-exploration-de-surface-aux-projets-bodo-et-l--51d14669-9d72-4d82-8fab-1970244a477d#fact-drill-facts-111)

BODO · cobalt

#### Identity

- Project: BODO
- Commodity: cobalt
- Region: canada\_qc
- Reported Region: Quebec
- Ticker: BGD

#### Geometry

- Grade: 0.002
- Grade Unit: %

#### Classification

- Sample Type: surface

#### QA/QC

- QP Signed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-16T00:00:00.000Z

Reasoning: This surface sample returned a cobalt grade below the weak threshold.

- Negative factor: Cobalt grade is below weak for default deposit type

- Negative factor: Surface sample has lower confidence than drill results

Evidence · table

> 20

Context: F671714

#### Tags used in scoring

**No QA/QC Disclosure**

Polarity: negative

Definition: Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc\_disclosed is not true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
