C3 Metals Continues to Intersect Broad Zones of Near-Surface Copper Mineralization at the Khaleesi Project, Peru
Original announcement by tmx on
- Company
- C3 Metals Inc.
- Ticker
- CCCM
- Exchange
- TSX
- Region
- Peru
- Primary commodity
- Copper
- Secondary commodities
- Gold, Silver, Molybdenum
- Document categories
- Drill results
- Extracted
- 2026-09-17 15:09:59 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
C3 Metals announced drill results from 11 holes at its Khaleesi copper project in southern Peru, intersecting broad zones of near-surface copper mineralization. Highlights include 148.05m at 0.42% CuEq and 43.80m at 0.59% CuEq, with high-grade sub-intervals up to 5.56% CuEq over 1.4m. The company considers the greenfield exploration program highly successful and plans further drilling to vector towards the system's core.
Reasoning: C3 Metals reported positive drill results from its Khaleesi project, confirming broad zones of near-surface copper mineralization, including high-grade intercepts. The ongoing exploration program is successfully defining the system, supported by robust QA/QC protocols, though true widths are yet to be determined.
Positive factors
- Broad zones of near-surface copper mineralization intersected
- High-grade sub-intervals reported
- Successful greenfield exploration program
- Comprehensive QA/QC disclosure
Negative factors
- True widths not yet determined for reported intercepts
- Early-stage project with no metallurgical test work completed for CuEq assumptions
Facts used in scoring: 69
Extracted facts
Stored fact records: 69. Some facts used in scoring do not have a stored record.
Drill Results (69)
KHZ5500-001Khaleesi · copperGrade: 0.23Grade Unit: %Intercept: 15.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 15.6 m
- From
- 12.2 m
- To
- 27.8 m
- Intercept Depth
- 12.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:12.2-27.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.25
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is near-surface but has a grade below the weak threshold for skarn copper deposits, making it less material, though it contributes to defining the mineralization footprint.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.23”
Context: 15.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · goldGrade: 0.01Grade Unit: g/tIntercept: 15.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 15.6 m
- From
- 12.2 m
- To
- 27.8 m
- Intercept Depth
- 12.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:12.2-27.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.25
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.010”
Context: 15.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · silverGrade: 0.41Grade Unit: g/tIntercept: 15.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 15.6 m
- From
- 12.2 m
- To
- 27.8 m
- Intercept Depth
- 12.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:12.2-27.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.25
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.41”
Context: 15.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · molybdenumGrade: 12Grade Unit: ppmIntercept: 15.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 12
- Grade Unit
- ppm
- Intercept
- 15.6 m
- From
- 12.2 m
- To
- 27.8 m
- Intercept Depth
- 12.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:12.2-27.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.25
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“12”
Context: 15.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · copperGrade: 0.19Grade Unit: %Intercept: 55.3 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 55.3 m
- From
- 271.7 m
- To
- 327 m
- Intercept Depth
- 271.7 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:271.7-327
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is broad but has a grade below the weak threshold, contributing to the overall mineralization footprint at depth.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.19”
Context: 55.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · goldGrade: 0.034Grade Unit: g/tIntercept: 55.3 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.034
- Grade Unit
- g/t
- Intercept
- 55.3 m
- From
- 271.7 m
- To
- 327 m
- Intercept Depth
- 271.7 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:271.7-327
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.034”
Context: 55.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · silverGrade: 0.83Grade Unit: g/tIntercept: 55.3 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.83
- Grade Unit
- g/t
- Intercept
- 55.3 m
- From
- 271.7 m
- To
- 327 m
- Intercept Depth
- 271.7 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:271.7-327
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.83”
Context: 55.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · molybdenumGrade: 108Grade Unit: ppmIntercept: 55.3 mView all detailsHide details
Identity
- Hole ID
- KHZ5500-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 108
- Grade Unit
- ppm
- Intercept
- 55.3 m
- From
- 271.7 m
- To
- 327 m
- Intercept Depth
- 271.7 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5500-001:271.7-327
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“108”
Context: 55.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.24Grade Unit: %Intercept: 45 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 45 m
- From
- 36.5 m
- To
- 81.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:36.5-81.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.3
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is broad and near-surface but has a grade below the weak threshold, contributing to the overall mineralization footprint.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.24”
Context: 45.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.046Grade Unit: g/tIntercept: 45 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.046
- Grade Unit
- g/t
- Intercept
- 45 m
- From
- 36.5 m
- To
- 81.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:36.5-81.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.3
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.046”
Context: 45.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 0.99Grade Unit: g/tIntercept: 45 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.99
- Grade Unit
- g/t
- Intercept
- 45 m
- From
- 36.5 m
- To
- 81.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:36.5-81.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.3
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.99”
Context: 45.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 13Grade Unit: ppmIntercept: 45 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 13
- Grade Unit
- ppm
- Intercept
- 45 m
- From
- 36.5 m
- To
- 81.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:36.5-81.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.3
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“13”
Context: 45.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.33Grade Unit: %Intercept: 26.5 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 26.5 m
- From
- 113.3 m
- To
- 139.8 m
- Intercept Depth
- 113.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:113.3-139.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.4
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a moderate grade over a good length, contributing positively to the overall mineralization model.
Positive factors
- Moderate copper grade
- Good intercept length
- QA/QC disclosed
Negative factors
- Apparent width only
Evidence · table
“0.33”
Context: 26.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.041Grade Unit: g/tIntercept: 26.5 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.041
- Grade Unit
- g/t
- Intercept
- 26.5 m
- From
- 113.3 m
- To
- 139.8 m
- Intercept Depth
- 113.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:113.3-139.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.4
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.041”
Context: 26.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 1Grade Unit: g/tIntercept: 26.5 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 1
- Grade Unit
- g/t
- Intercept
- 26.5 m
- From
- 113.3 m
- To
- 139.8 m
- Intercept Depth
- 113.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:113.3-139.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.4
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“1.00”
Context: 26.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 29Grade Unit: ppmIntercept: 26.5 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 29
- Grade Unit
- ppm
- Intercept
- 26.5 m
- From
- 113.3 m
- To
- 139.8 m
- Intercept Depth
- 113.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:113.3-139.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.4
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“29”
Context: 26.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.2Grade Unit: %Intercept: 27.2 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 27.2 m
- From
- 359.2 m
- To
- 386.4 m
- Intercept Depth
- 359.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:359.2-386.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is of good length but has a grade below the weak threshold, contributing to the overall mineralization footprint at depth.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.20”
Context: 27.20
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.011Grade Unit: g/tIntercept: 27.2 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.011
- Grade Unit
- g/t
- Intercept
- 27.2 m
- From
- 359.2 m
- To
- 386.4 m
- Intercept Depth
- 359.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:359.2-386.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.011”
Context: 27.20
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 0.53Grade Unit: g/tIntercept: 27.2 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 27.2 m
- From
- 359.2 m
- To
- 386.4 m
- Intercept Depth
- 359.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:359.2-386.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.53”
Context: 27.20
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 4Grade Unit: ppmIntercept: 27.2 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 4
- Grade Unit
- ppm
- Intercept
- 27.2 m
- From
- 359.2 m
- To
- 386.4 m
- Intercept Depth
- 359.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:359.2-386.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is very low
- Apparent width only
Evidence · table
“4”
Context: 27.20
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.16Grade Unit: %Intercept: 30.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 30.7 m
- From
- 420.3 m
- To
- 451 m
- Intercept Depth
- 420.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:420.3-451
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint at depth.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.16”
Context: 30.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.011Grade Unit: g/tIntercept: 30.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.011
- Grade Unit
- g/t
- Intercept
- 30.7 m
- From
- 420.3 m
- To
- 451 m
- Intercept Depth
- 420.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:420.3-451
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.011”
Context: 30.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 0.4Grade Unit: g/tIntercept: 30.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 30.7 m
- From
- 420.3 m
- To
- 451 m
- Intercept Depth
- 420.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:420.3-451
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.40”
Context: 30.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 12Grade Unit: ppmIntercept: 30.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5550-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 12
- Grade Unit
- ppm
- Intercept
- 30.7 m
- From
- 420.3 m
- To
- 451 m
- Intercept Depth
- 420.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5550-001:420.3-451
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“12”
Context: 30.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 1.6Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 1.6
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 15.1 m
- To
- 16 m
- Intercept Depth
- 15.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:15.1-16
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.61
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a strong grade near surface, but its narrow length limits its overall materiality.
Positive factors
- Strong copper grade
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Narrow intercept length
- Apparent width only
Evidence · table
“1.60”
Context: 0.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.009Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.009
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 15.1 m
- To
- 16 m
- Intercept Depth
- 15.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:15.1-16
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.61
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Narrow intercept length
- Apparent width only
Evidence · table
“0.009”
Context: 0.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.32Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 15.1 m
- To
- 16 m
- Intercept Depth
- 15.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:15.1-16
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.61
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Narrow intercept length
- Apparent width only
Evidence · table
“0.32”
Context: 0.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 0Grade Unit: ppmIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0
- Grade Unit
- ppm
- Intercept
- 0.9 m
- From
- 15.1 m
- To
- 16 m
- Intercept Depth
- 15.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:15.1-16
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.61
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: No molybdenum was detected in this narrow, near-surface intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- No molybdenum detected
- Narrow intercept length
- Apparent width only
Evidence · table
“0”
Context: 0.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 0.18Grade Unit: %Intercept: 10.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.18
- Grade Unit
- %
- Intercept
- 10.6 m
- From
- 168.8 m
- To
- 179.4 m
- Intercept Depth
- 168.8 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:168.8-179.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.18”
Context: 10.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.011Grade Unit: g/tIntercept: 10.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.011
- Grade Unit
- g/t
- Intercept
- 10.6 m
- From
- 168.8 m
- To
- 179.4 m
- Intercept Depth
- 168.8 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:168.8-179.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.011”
Context: 10.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.8Grade Unit: g/tIntercept: 10.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 10.6 m
- From
- 168.8 m
- To
- 179.4 m
- Intercept Depth
- 168.8 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:168.8-179.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.80”
Context: 10.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 33Grade Unit: ppmIntercept: 10.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 33
- Grade Unit
- ppm
- Intercept
- 10.6 m
- From
- 168.8 m
- To
- 179.4 m
- Intercept Depth
- 168.8 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:168.8-179.4
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.22
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“33”
Context: 10.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 0.17Grade Unit: %Intercept: 14.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 14.9 m
- From
- 195.4 m
- To
- 210.3 m
- Intercept Depth
- 195.4 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:195.4-210.3
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.23
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.17”
Context: 14.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.006Grade Unit: g/tIntercept: 14.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.006
- Grade Unit
- g/t
- Intercept
- 14.9 m
- From
- 195.4 m
- To
- 210.3 m
- Intercept Depth
- 195.4 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:195.4-210.3
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.23
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.006”
Context: 14.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.39Grade Unit: g/tIntercept: 14.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 14.9 m
- From
- 195.4 m
- To
- 210.3 m
- Intercept Depth
- 195.4 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:195.4-210.3
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.23
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.39”
Context: 14.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 84Grade Unit: ppmIntercept: 14.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 84
- Grade Unit
- ppm
- Intercept
- 14.9 m
- From
- 195.4 m
- To
- 210.3 m
- Intercept Depth
- 195.4 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:195.4-210.3
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.23
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“84”
Context: 14.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 0.16Grade Unit: %Intercept: 14.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 14.6 m
- From
- 245.6 m
- To
- 260.2 m
- Intercept Depth
- 245.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:245.6-260.2
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade below weak threshold for copper
- Apparent width only
Evidence · table
“0.16”
Context: 14.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.007Grade Unit: g/tIntercept: 14.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.007
- Grade Unit
- g/t
- Intercept
- 14.6 m
- From
- 245.6 m
- To
- 260.2 m
- Intercept Depth
- 245.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:245.6-260.2
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.007”
Context: 14.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.89Grade Unit: g/tIntercept: 14.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.89
- Grade Unit
- g/t
- Intercept
- 14.6 m
- From
- 245.6 m
- To
- 260.2 m
- Intercept Depth
- 245.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:245.6-260.2
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.89”
Context: 14.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 21Grade Unit: ppmIntercept: 14.6 mView all detailsHide details
Identity
- Hole ID
- KHZ5675-002
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 21
- Grade Unit
- ppm
- Intercept
- 14.6 m
- From
- 245.6 m
- To
- 260.2 m
- Intercept Depth
- 245.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5675-002:245.6-260.2
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.18
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“21”
Context: 14.60
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 0.27Grade Unit: %Intercept: 5.1 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 5.1 m
- From
- 13.6 m
- To
- 18.7 m
- Intercept Depth
- 13.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:13.6-18.7
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a moderate grade near surface, but its narrow length limits its overall materiality.
Positive factors
- Moderate copper grade
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Narrow intercept length
- Apparent width only
Evidence · table
“0.27”
Context: 5.10
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.055Grade Unit: g/tIntercept: 5.1 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.055
- Grade Unit
- g/t
- Intercept
- 5.1 m
- From
- 13.6 m
- To
- 18.7 m
- Intercept Depth
- 13.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:13.6-18.7
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Narrow intercept length
- Apparent width only
Evidence · table
“0.055”
Context: 5.10
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 1.68Grade Unit: g/tIntercept: 5.1 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 1.68
- Grade Unit
- g/t
- Intercept
- 5.1 m
- From
- 13.6 m
- To
- 18.7 m
- Intercept Depth
- 13.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:13.6-18.7
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Narrow intercept length
- Apparent width only
Evidence · table
“1.68”
Context: 5.10
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 22Grade Unit: ppmIntercept: 5.1 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 22
- Grade Unit
- ppm
- Intercept
- 5.1 m
- From
- 13.6 m
- To
- 18.7 m
- Intercept Depth
- 13.6 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:13.6-18.7
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Narrow intercept length
- Apparent width only
Evidence · table
“22”
Context: 5.10
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 0.47Grade Unit: %Intercept: 43.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.47
- Grade Unit
- %
- Intercept
- 43.8 m
- From
- 40.1 m
- To
- 83.9 m
- Intercept Depth
- 40.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:40.1-83.9
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.59
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a moderate grade over a broad length near surface, indicating significant mineralization and contributing positively to the project's potential.
Positive factors
- Moderate copper grade
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Apparent width only
Evidence · table
“0.47”
Context: 43.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.087Grade Unit: g/tIntercept: 43.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.087
- Grade Unit
- g/t
- Intercept
- 43.8 m
- From
- 40.1 m
- To
- 83.9 m
- Intercept Depth
- 40.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:40.1-83.9
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.59
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.087”
Context: 43.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 2.17Grade Unit: g/tIntercept: 43.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 2.17
- Grade Unit
- g/t
- Intercept
- 43.8 m
- From
- 40.1 m
- To
- 83.9 m
- Intercept Depth
- 40.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:40.1-83.9
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.59
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“2.17”
Context: 43.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 48Grade Unit: ppmIntercept: 43.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 48
- Grade Unit
- ppm
- Intercept
- 43.8 m
- From
- 40.1 m
- To
- 83.9 m
- Intercept Depth
- 40.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:40.1-83.9
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.59
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“48”
Context: 43.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 1.49Grade Unit: %Intercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 1.49
- Grade Unit
- %
- Intercept
- 3.8 m
- From
- 42 m
- To
- 45.8 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:42-45.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.8
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a strong grade near surface, but its narrow length limits its overall materiality, though it highlights high-grade potential within the broader zone.
Positive factors
- Strong copper grade
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Narrow intercept length
- Apparent width only
Evidence · table
“1.49”
Context: 3.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.243Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.243
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 42 m
- To
- 45.8 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:42-45.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.8
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is below the weak threshold and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is below weak threshold for gold
- Narrow intercept length
- Apparent width only
Evidence · table
“0.243”
Context: 3.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 7.67Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 7.67
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 42 m
- To
- 45.8 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:42-45.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.8
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Narrow intercept length
- Apparent width only
Evidence · table
“7.67”
Context: 3.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 17Grade Unit: ppmIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 17
- Grade Unit
- ppm
- Intercept
- 3.8 m
- From
- 42 m
- To
- 45.8 m
- Intercept Depth
- 42 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:42-45.8
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.8
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Narrow intercept length
- Apparent width only
Evidence · table
“17”
Context: 3.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 4.91Grade Unit: %Intercept: 1.4 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 4.91
- Grade Unit
- %
- Intercept
- 1.4 m
- From
- 77.1 m
- To
- 78.5 m
- Intercept Depth
- 77.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:77.1-78.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 5.56
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows an exceptional grade, highlighting very high-grade potential within the broader mineralization, despite its very narrow length.
Positive factors
- Exceptional copper grade
- QA/QC disclosed
Negative factors
- Very narrow intercept length
- Apparent width only
Evidence · table
“4.91”
Context: 1.40
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Copper grade of 4.91% is well above the exceptional threshold (2.5%) for skarn deposits.
Evidence · table
“4.91”
Context: 1.40
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.419Grade Unit: g/tIntercept: 1.4 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.419
- Grade Unit
- g/t
- Intercept
- 1.4 m
- From
- 77.1 m
- To
- 78.5 m
- Intercept Depth
- 77.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:77.1-78.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 5.56
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This gold intercept shows a moderate grade, contributing to the high-grade polymetallic nature of the narrow zone.
Positive factors
- Moderate gold grade
- QA/QC disclosed
Negative factors
- Very narrow intercept length
- Apparent width only
Evidence · table
“0.419”
Context: 1.40
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 17.35Grade Unit: g/tIntercept: 1.4 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 17.35
- Grade Unit
- g/t
- Intercept
- 1.4 m
- From
- 77.1 m
- To
- 78.5 m
- Intercept Depth
- 77.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:77.1-78.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 5.56
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Very narrow intercept length
- Apparent width only
Evidence · table
“17.35”
Context: 1.40
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 164Grade Unit: ppmIntercept: 1.4 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 164
- Grade Unit
- ppm
- Intercept
- 1.4 m
- From
- 77.1 m
- To
- 78.5 m
- Intercept Depth
- 77.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:77.1-78.5
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 5.56
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Very narrow intercept length
- Apparent width only
Evidence · table
“164”
Context: 1.40
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 0.3Grade Unit: %Intercept: 33.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 33.7 m
- From
- 95.3 m
- To
- 129 m
- Intercept Depth
- 95.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:95.3-129
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.33
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a moderate grade over a broad length, contributing positively to the overall mineralization model.
Positive factors
- Moderate copper grade
- Broad intercept length
- QA/QC disclosed
Negative factors
- Apparent width only
Evidence · table
“0.30”
Context: 33.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.014Grade Unit: g/tIntercept: 33.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.014
- Grade Unit
- g/t
- Intercept
- 33.7 m
- From
- 95.3 m
- To
- 129 m
- Intercept Depth
- 95.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:95.3-129
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.33
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.014”
Context: 33.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 0.63Grade Unit: g/tIntercept: 33.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
- Intercept
- 33.7 m
- From
- 95.3 m
- To
- 129 m
- Intercept Depth
- 95.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:95.3-129
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.33
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.63”
Context: 33.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 27Grade Unit: ppmIntercept: 33.7 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-001
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 27
- Grade Unit
- ppm
- Intercept
- 33.7 m
- From
- 95.3 m
- To
- 129 m
- Intercept Depth
- 95.3 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-001:95.3-129
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.33
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“27”
Context: 33.70
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · copperGrade: 0.29Grade Unit: %Intercept: 72.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 72.9 m
- From
- 346.1 m
- To
- 419 m
- Intercept Depth
- 346.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:346.1-419
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a moderate grade over a broad length, contributing positively to the overall mineralization model at depth.
Positive factors
- Broad intercept length
- Moderate copper grade
- QA/QC disclosed
Negative factors
- Apparent width only
Evidence · table
“0.29”
Context: 72.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · goldGrade: 0.039Grade Unit: g/tIntercept: 72.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.039
- Grade Unit
- g/t
- Intercept
- 72.9 m
- From
- 346.1 m
- To
- 419 m
- Intercept Depth
- 346.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:346.1-419
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.039”
Context: 72.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · silverGrade: 1.27Grade Unit: g/tIntercept: 72.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 1.27
- Grade Unit
- g/t
- Intercept
- 72.9 m
- From
- 346.1 m
- To
- 419 m
- Intercept Depth
- 346.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:346.1-419
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“1.27”
Context: 72.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · molybdenumGrade: 22Grade Unit: ppmIntercept: 72.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 22
- Grade Unit
- ppm
- Intercept
- 72.9 m
- From
- 346.1 m
- To
- 419 m
- Intercept Depth
- 346.1 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:346.1-419
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.35
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Broad intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“22”
Context: 72.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · copperGrade: 0.33Grade Unit: %Intercept: 22.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 22.9 m
- From
- 432.2 m
- To
- 455.1 m
- Intercept Depth
- 432.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:432.2-455.1
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.37
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a moderate grade over a good length, contributing positively to the overall mineralization model at depth.
Positive factors
- Moderate copper grade
- Good intercept length
- QA/QC disclosed
Negative factors
- Apparent width only
Evidence · table
“0.33”
Context: 22.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · goldGrade: 0.034Grade Unit: g/tIntercept: 22.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.034
- Grade Unit
- g/t
- Intercept
- 22.9 m
- From
- 432.2 m
- To
- 455.1 m
- Intercept Depth
- 432.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:432.2-455.1
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.37
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for gold
- Apparent width only
Evidence · table
“0.034”
Context: 22.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · silverGrade: 0.89Grade Unit: g/tIntercept: 22.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 0.89
- Grade Unit
- g/t
- Intercept
- 22.9 m
- From
- 432.2 m
- To
- 455.1 m
- Intercept Depth
- 432.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:432.2-455.1
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.37
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Grade is very low for silver
- Apparent width only
Evidence · table
“0.89”
Context: 22.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · molybdenumGrade: 12Grade Unit: ppmIntercept: 22.9 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-002
- Project
- Khaleesi
- Commodity
- molybdenum
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 12
- Grade Unit
- ppm
- Intercept
- 22.9 m
- From
- 432.2 m
- To
- 455.1 m
- Intercept Depth
- 432.2 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-002:432.2-455.1
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 0.37
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.
Positive factors
- Good intercept length
- QA/QC disclosed
Negative factors
- Molybdenum grade is low
- Apparent width only
Evidence · table
“12”
Context: 22.90
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-003Khaleesi · copperGrade: 1.05Grade Unit: %Intercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- KHZ5790-003
- Project
- Khaleesi
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- CCCM
Geometry
- Grade
- 1.05
- Grade Unit
- %
- Intercept
- 2.75 m
- From
- 14.5 m
- To
- 17.25 m
- Intercept Depth
- 14.5 m
Classification
- Deposit Type
- skarn
- Program
- exploration
- Sample Type
- drill
- Group ID
- KHZ5790-003:14.5-17.25
- Mining Method
- unknown
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Metal Eq. Grade
- 1.23
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 0.15
- Cutoff Unit
- % Cu
- Dilution Disclosed
- Yes
- Max Dilution
- 12 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-04-29T00:00:00.000Z
Reasoning: This copper intercept shows a strong grade near surface, but its narrow length limits its overall materiality.
Positive factors
- Strong copper grade
- Near-surface intercept
- QA/QC disclosed
Negative factors
- Narrow intercept length
- Apparent width only
Evidence · table
“1.05”
Context: 2.75
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation.
Evidence · text
“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.