C3 Metals Continues to Intersect Broad Zones of Near-Surface Copper Mineralization at the Khaleesi Project, Peru

Original announcement by tmx on

Company
C3 Metals Inc.
Ticker
CCCM
Exchange
TSX
Region
Peru
Primary commodity
Copper
Secondary commodities
Gold, Silver, Molybdenum
Document categories
Drill results
Extracted
2026-09-17 15:09:59 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

C3 Metals announced drill results from 11 holes at its Khaleesi copper project in southern Peru, intersecting broad zones of near-surface copper mineralization. Highlights include 148.05m at 0.42% CuEq and 43.80m at 0.59% CuEq, with high-grade sub-intervals up to 5.56% CuEq over 1.4m. The company considers the greenfield exploration program highly successful and plans further drilling to vector towards the system's core.

Reasoning: C3 Metals reported positive drill results from its Khaleesi project, confirming broad zones of near-surface copper mineralization, including high-grade intercepts. The ongoing exploration program is successfully defining the system, supported by robust QA/QC protocols, though true widths are yet to be determined.

Positive factors

  • Broad zones of near-surface copper mineralization intersected
  • High-grade sub-intervals reported
  • Successful greenfield exploration program
  • Comprehensive QA/QC disclosure

Negative factors

  • True widths not yet determined for reported intercepts
  • Early-stage project with no metallurgical test work completed for CuEq assumptions

Facts used in scoring: 69

Extracted facts

Stored fact records: 69. Some facts used in scoring do not have a stored record.

Drill Results (69)

KHZ5500-001Khaleesi · copperGrade: 0.23Grade Unit: %Intercept: 15.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.23
Grade Unit
%
Intercept
15.6 m
From
12.2 m
To
27.8 m
Intercept Depth
12.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:12.2-27.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is near-surface but has a grade below the weak threshold for skarn copper deposits, making it less material, though it contributes to defining the mineralization footprint.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.23”

Context: 15.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · goldGrade: 0.01Grade Unit: g/tIntercept: 15.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
15.6 m
From
12.2 m
To
27.8 m
Intercept Depth
12.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:12.2-27.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.010”

Context: 15.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · silverGrade: 0.41Grade Unit: g/tIntercept: 15.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
15.6 m
From
12.2 m
To
27.8 m
Intercept Depth
12.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:12.2-27.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.41”

Context: 15.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · molybdenumGrade: 12Grade Unit: ppmIntercept: 15.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
12
Grade Unit
ppm
Intercept
15.6 m
From
12.2 m
To
27.8 m
Intercept Depth
12.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:12.2-27.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“12”

Context: 15.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · copperGrade: 0.19Grade Unit: %Intercept: 55.3 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.19
Grade Unit
%
Intercept
55.3 m
From
271.7 m
To
327 m
Intercept Depth
271.7 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:271.7-327
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is broad but has a grade below the weak threshold, contributing to the overall mineralization footprint at depth.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.19”

Context: 55.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · goldGrade: 0.034Grade Unit: g/tIntercept: 55.3 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.034
Grade Unit
g/t
Intercept
55.3 m
From
271.7 m
To
327 m
Intercept Depth
271.7 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:271.7-327
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.034”

Context: 55.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · silverGrade: 0.83Grade Unit: g/tIntercept: 55.3 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.83
Grade Unit
g/t
Intercept
55.3 m
From
271.7 m
To
327 m
Intercept Depth
271.7 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:271.7-327
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.83”

Context: 55.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5500-001Khaleesi · molybdenumGrade: 108Grade Unit: ppmIntercept: 55.3 mView all details
Link to this fact

Identity

Hole ID
KHZ5500-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
108
Grade Unit
ppm
Intercept
55.3 m
From
271.7 m
To
327 m
Intercept Depth
271.7 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5500-001:271.7-327
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“108”

Context: 55.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.24Grade Unit: %Intercept: 45 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.24
Grade Unit
%
Intercept
45 m
From
36.5 m
To
81.5 m
Intercept Depth
36.5 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:36.5-81.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is broad and near-surface but has a grade below the weak threshold, contributing to the overall mineralization footprint.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.24”

Context: 45.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.046Grade Unit: g/tIntercept: 45 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.046
Grade Unit
g/t
Intercept
45 m
From
36.5 m
To
81.5 m
Intercept Depth
36.5 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:36.5-81.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.046”

Context: 45.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 0.99Grade Unit: g/tIntercept: 45 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.99
Grade Unit
g/t
Intercept
45 m
From
36.5 m
To
81.5 m
Intercept Depth
36.5 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:36.5-81.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.99”

Context: 45.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 13Grade Unit: ppmIntercept: 45 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
13
Grade Unit
ppm
Intercept
45 m
From
36.5 m
To
81.5 m
Intercept Depth
36.5 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:36.5-81.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.3
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“13”

Context: 45.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.33Grade Unit: %Intercept: 26.5 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.33
Grade Unit
%
Intercept
26.5 m
From
113.3 m
To
139.8 m
Intercept Depth
113.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:113.3-139.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a moderate grade over a good length, contributing positively to the overall mineralization model.

Positive factors

  • Moderate copper grade
  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Apparent width only

Evidence · table

“0.33”

Context: 26.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.041Grade Unit: g/tIntercept: 26.5 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.041
Grade Unit
g/t
Intercept
26.5 m
From
113.3 m
To
139.8 m
Intercept Depth
113.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:113.3-139.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.041”

Context: 26.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 1Grade Unit: g/tIntercept: 26.5 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
1
Grade Unit
g/t
Intercept
26.5 m
From
113.3 m
To
139.8 m
Intercept Depth
113.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:113.3-139.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“1.00”

Context: 26.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 29Grade Unit: ppmIntercept: 26.5 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
29
Grade Unit
ppm
Intercept
26.5 m
From
113.3 m
To
139.8 m
Intercept Depth
113.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:113.3-139.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“29”

Context: 26.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.2Grade Unit: %Intercept: 27.2 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.2
Grade Unit
%
Intercept
27.2 m
From
359.2 m
To
386.4 m
Intercept Depth
359.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:359.2-386.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is of good length but has a grade below the weak threshold, contributing to the overall mineralization footprint at depth.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.20”

Context: 27.20

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.011Grade Unit: g/tIntercept: 27.2 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.011
Grade Unit
g/t
Intercept
27.2 m
From
359.2 m
To
386.4 m
Intercept Depth
359.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:359.2-386.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.011”

Context: 27.20

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 0.53Grade Unit: g/tIntercept: 27.2 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.53
Grade Unit
g/t
Intercept
27.2 m
From
359.2 m
To
386.4 m
Intercept Depth
359.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:359.2-386.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.53”

Context: 27.20

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 4Grade Unit: ppmIntercept: 27.2 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
4
Grade Unit
ppm
Intercept
27.2 m
From
359.2 m
To
386.4 m
Intercept Depth
359.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:359.2-386.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is very low
  • Apparent width only

Evidence · table

“4”

Context: 27.20

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · copperGrade: 0.16Grade Unit: %Intercept: 30.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.16
Grade Unit
%
Intercept
30.7 m
From
420.3 m
To
451 m
Intercept Depth
420.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:420.3-451
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint at depth.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.16”

Context: 30.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · goldGrade: 0.011Grade Unit: g/tIntercept: 30.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.011
Grade Unit
g/t
Intercept
30.7 m
From
420.3 m
To
451 m
Intercept Depth
420.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:420.3-451
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.011”

Context: 30.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · silverGrade: 0.4Grade Unit: g/tIntercept: 30.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
30.7 m
From
420.3 m
To
451 m
Intercept Depth
420.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:420.3-451
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.40”

Context: 30.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5550-001Khaleesi · molybdenumGrade: 12Grade Unit: ppmIntercept: 30.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5550-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
12
Grade Unit
ppm
Intercept
30.7 m
From
420.3 m
To
451 m
Intercept Depth
420.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5550-001:420.3-451
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“12”

Context: 30.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 1.6Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
1.6
Grade Unit
%
Intercept
0.9 m
From
15.1 m
To
16 m
Intercept Depth
15.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:15.1-16
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a strong grade near surface, but its narrow length limits its overall materiality.

Positive factors

  • Strong copper grade
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Narrow intercept length
  • Apparent width only

Evidence · table

“1.60”

Context: 0.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.009Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.009
Grade Unit
g/t
Intercept
0.9 m
From
15.1 m
To
16 m
Intercept Depth
15.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:15.1-16
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Narrow intercept length
  • Apparent width only

Evidence · table

“0.009”

Context: 0.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.32Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.32
Grade Unit
g/t
Intercept
0.9 m
From
15.1 m
To
16 m
Intercept Depth
15.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:15.1-16
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Narrow intercept length
  • Apparent width only

Evidence · table

“0.32”

Context: 0.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 0Grade Unit: ppmIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0
Grade Unit
ppm
Intercept
0.9 m
From
15.1 m
To
16 m
Intercept Depth
15.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:15.1-16
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: No molybdenum was detected in this narrow, near-surface intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • No molybdenum detected
  • Narrow intercept length
  • Apparent width only

Evidence · table

“0”

Context: 0.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 0.18Grade Unit: %Intercept: 10.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.18
Grade Unit
%
Intercept
10.6 m
From
168.8 m
To
179.4 m
Intercept Depth
168.8 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:168.8-179.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.18”

Context: 10.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.011Grade Unit: g/tIntercept: 10.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.011
Grade Unit
g/t
Intercept
10.6 m
From
168.8 m
To
179.4 m
Intercept Depth
168.8 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:168.8-179.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.011”

Context: 10.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.8Grade Unit: g/tIntercept: 10.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.8
Grade Unit
g/t
Intercept
10.6 m
From
168.8 m
To
179.4 m
Intercept Depth
168.8 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:168.8-179.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.80”

Context: 10.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 33Grade Unit: ppmIntercept: 10.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
33
Grade Unit
ppm
Intercept
10.6 m
From
168.8 m
To
179.4 m
Intercept Depth
168.8 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:168.8-179.4
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“33”

Context: 10.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 0.17Grade Unit: %Intercept: 14.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.17
Grade Unit
%
Intercept
14.9 m
From
195.4 m
To
210.3 m
Intercept Depth
195.4 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:195.4-210.3
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.17”

Context: 14.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.006Grade Unit: g/tIntercept: 14.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.006
Grade Unit
g/t
Intercept
14.9 m
From
195.4 m
To
210.3 m
Intercept Depth
195.4 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:195.4-210.3
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.006”

Context: 14.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.39Grade Unit: g/tIntercept: 14.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.39
Grade Unit
g/t
Intercept
14.9 m
From
195.4 m
To
210.3 m
Intercept Depth
195.4 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:195.4-210.3
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.39”

Context: 14.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 84Grade Unit: ppmIntercept: 14.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
84
Grade Unit
ppm
Intercept
14.9 m
From
195.4 m
To
210.3 m
Intercept Depth
195.4 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:195.4-210.3
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“84”

Context: 14.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · copperGrade: 0.16Grade Unit: %Intercept: 14.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.16
Grade Unit
%
Intercept
14.6 m
From
245.6 m
To
260.2 m
Intercept Depth
245.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:245.6-260.2
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept is of good length but has a grade just above the cutoff, contributing to the overall mineralization footprint.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade below weak threshold for copper
  • Apparent width only

Evidence · table

“0.16”

Context: 14.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · goldGrade: 0.007Grade Unit: g/tIntercept: 14.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.007
Grade Unit
g/t
Intercept
14.6 m
From
245.6 m
To
260.2 m
Intercept Depth
245.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:245.6-260.2
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.007”

Context: 14.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · silverGrade: 0.89Grade Unit: g/tIntercept: 14.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.89
Grade Unit
g/t
Intercept
14.6 m
From
245.6 m
To
260.2 m
Intercept Depth
245.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:245.6-260.2
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.89”

Context: 14.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5675-002Khaleesi · molybdenumGrade: 21Grade Unit: ppmIntercept: 14.6 mView all details
Link to this fact

Identity

Hole ID
KHZ5675-002
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
21
Grade Unit
ppm
Intercept
14.6 m
From
245.6 m
To
260.2 m
Intercept Depth
245.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5675-002:245.6-260.2
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“21”

Context: 14.60

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 0.27Grade Unit: %Intercept: 5.1 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.27
Grade Unit
%
Intercept
5.1 m
From
13.6 m
To
18.7 m
Intercept Depth
13.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:13.6-18.7
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a moderate grade near surface, but its narrow length limits its overall materiality.

Positive factors

  • Moderate copper grade
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Narrow intercept length
  • Apparent width only

Evidence · table

“0.27”

Context: 5.10

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.055Grade Unit: g/tIntercept: 5.1 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.055
Grade Unit
g/t
Intercept
5.1 m
From
13.6 m
To
18.7 m
Intercept Depth
13.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:13.6-18.7
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Narrow intercept length
  • Apparent width only

Evidence · table

“0.055”

Context: 5.10

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 1.68Grade Unit: g/tIntercept: 5.1 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
1.68
Grade Unit
g/t
Intercept
5.1 m
From
13.6 m
To
18.7 m
Intercept Depth
13.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:13.6-18.7
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Narrow intercept length
  • Apparent width only

Evidence · table

“1.68”

Context: 5.10

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 22Grade Unit: ppmIntercept: 5.1 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
22
Grade Unit
ppm
Intercept
5.1 m
From
13.6 m
To
18.7 m
Intercept Depth
13.6 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:13.6-18.7
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Narrow intercept length
  • Apparent width only

Evidence · table

“22”

Context: 5.10

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 0.47Grade Unit: %Intercept: 43.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.47
Grade Unit
%
Intercept
43.8 m
From
40.1 m
To
83.9 m
Intercept Depth
40.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:40.1-83.9
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.59
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a moderate grade over a broad length near surface, indicating significant mineralization and contributing positively to the project's potential.

Positive factors

  • Moderate copper grade
  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Apparent width only

Evidence · table

“0.47”

Context: 43.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.087Grade Unit: g/tIntercept: 43.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.087
Grade Unit
g/t
Intercept
43.8 m
From
40.1 m
To
83.9 m
Intercept Depth
40.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:40.1-83.9
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.59
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.087”

Context: 43.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 2.17Grade Unit: g/tIntercept: 43.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
2.17
Grade Unit
g/t
Intercept
43.8 m
From
40.1 m
To
83.9 m
Intercept Depth
40.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:40.1-83.9
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.59
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“2.17”

Context: 43.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 48Grade Unit: ppmIntercept: 43.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
48
Grade Unit
ppm
Intercept
43.8 m
From
40.1 m
To
83.9 m
Intercept Depth
40.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:40.1-83.9
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.59
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“48”

Context: 43.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 1.49Grade Unit: %Intercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
1.49
Grade Unit
%
Intercept
3.8 m
From
42 m
To
45.8 m
Intercept Depth
42 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:42-45.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a strong grade near surface, but its narrow length limits its overall materiality, though it highlights high-grade potential within the broader zone.

Positive factors

  • Strong copper grade
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Narrow intercept length
  • Apparent width only

Evidence · table

“1.49”

Context: 3.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.243Grade Unit: g/tIntercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.243
Grade Unit
g/t
Intercept
3.8 m
From
42 m
To
45.8 m
Intercept Depth
42 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:42-45.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is below the weak threshold and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is below weak threshold for gold
  • Narrow intercept length
  • Apparent width only

Evidence · table

“0.243”

Context: 3.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 7.67Grade Unit: g/tIntercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
7.67
Grade Unit
g/t
Intercept
3.8 m
From
42 m
To
45.8 m
Intercept Depth
42 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:42-45.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Narrow intercept length
  • Apparent width only

Evidence · table

“7.67”

Context: 3.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 17Grade Unit: ppmIntercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
17
Grade Unit
ppm
Intercept
3.8 m
From
42 m
To
45.8 m
Intercept Depth
42 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:42-45.8
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Narrow intercept length
  • Apparent width only

Evidence · table

“17”

Context: 3.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 4.91Grade Unit: %Intercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
4.91
Grade Unit
%
Intercept
1.4 m
From
77.1 m
To
78.5 m
Intercept Depth
77.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:77.1-78.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
5.56
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows an exceptional grade, highlighting very high-grade potential within the broader mineralization, despite its very narrow length.

Positive factors

  • Exceptional copper grade
  • QA/QC disclosed

Negative factors

  • Very narrow intercept length
  • Apparent width only

Evidence · table

“4.91”

Context: 1.40

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Copper grade of 4.91% is well above the exceptional threshold (2.5%) for skarn deposits.

Evidence · table

“4.91”

Context: 1.40

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.419Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.419
Grade Unit
g/t
Intercept
1.4 m
From
77.1 m
To
78.5 m
Intercept Depth
77.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:77.1-78.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
5.56
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This gold intercept shows a moderate grade, contributing to the high-grade polymetallic nature of the narrow zone.

Positive factors

  • Moderate gold grade
  • QA/QC disclosed

Negative factors

  • Very narrow intercept length
  • Apparent width only

Evidence · table

“0.419”

Context: 1.40

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 17.35Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
17.35
Grade Unit
g/t
Intercept
1.4 m
From
77.1 m
To
78.5 m
Intercept Depth
77.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:77.1-78.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
5.56
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Very narrow intercept length
  • Apparent width only

Evidence · table

“17.35”

Context: 1.40

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 164Grade Unit: ppmIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
164
Grade Unit
ppm
Intercept
1.4 m
From
77.1 m
To
78.5 m
Intercept Depth
77.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:77.1-78.5
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
5.56
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Very narrow intercept length
  • Apparent width only

Evidence · table

“164”

Context: 1.40

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · copperGrade: 0.3Grade Unit: %Intercept: 33.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.3
Grade Unit
%
Intercept
33.7 m
From
95.3 m
To
129 m
Intercept Depth
95.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:95.3-129
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a moderate grade over a broad length, contributing positively to the overall mineralization model.

Positive factors

  • Moderate copper grade
  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Apparent width only

Evidence · table

“0.30”

Context: 33.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · goldGrade: 0.014Grade Unit: g/tIntercept: 33.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.014
Grade Unit
g/t
Intercept
33.7 m
From
95.3 m
To
129 m
Intercept Depth
95.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:95.3-129
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.014”

Context: 33.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · silverGrade: 0.63Grade Unit: g/tIntercept: 33.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.63
Grade Unit
g/t
Intercept
33.7 m
From
95.3 m
To
129 m
Intercept Depth
95.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:95.3-129
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.63”

Context: 33.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-001Khaleesi · molybdenumGrade: 27Grade Unit: ppmIntercept: 33.7 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-001
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
27
Grade Unit
ppm
Intercept
33.7 m
From
95.3 m
To
129 m
Intercept Depth
95.3 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-001:95.3-129
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“27”

Context: 33.70

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · copperGrade: 0.29Grade Unit: %Intercept: 72.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.29
Grade Unit
%
Intercept
72.9 m
From
346.1 m
To
419 m
Intercept Depth
346.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:346.1-419
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a moderate grade over a broad length, contributing positively to the overall mineralization model at depth.

Positive factors

  • Broad intercept length
  • Moderate copper grade
  • QA/QC disclosed

Negative factors

  • Apparent width only

Evidence · table

“0.29”

Context: 72.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · goldGrade: 0.039Grade Unit: g/tIntercept: 72.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.039
Grade Unit
g/t
Intercept
72.9 m
From
346.1 m
To
419 m
Intercept Depth
346.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:346.1-419
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.039”

Context: 72.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · silverGrade: 1.27Grade Unit: g/tIntercept: 72.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
1.27
Grade Unit
g/t
Intercept
72.9 m
From
346.1 m
To
419 m
Intercept Depth
346.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:346.1-419
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“1.27”

Context: 72.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · molybdenumGrade: 22Grade Unit: ppmIntercept: 72.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
22
Grade Unit
ppm
Intercept
72.9 m
From
346.1 m
To
419 m
Intercept Depth
346.1 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:346.1-419
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Broad intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“22”

Context: 72.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · copperGrade: 0.33Grade Unit: %Intercept: 22.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.33
Grade Unit
%
Intercept
22.9 m
From
432.2 m
To
455.1 m
Intercept Depth
432.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:432.2-455.1
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a moderate grade over a good length, contributing positively to the overall mineralization model at depth.

Positive factors

  • Moderate copper grade
  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Apparent width only

Evidence · table

“0.33”

Context: 22.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · goldGrade: 0.034Grade Unit: g/tIntercept: 22.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
gold
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.034
Grade Unit
g/t
Intercept
22.9 m
From
432.2 m
To
455.1 m
Intercept Depth
432.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:432.2-455.1
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The gold grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for gold
  • Apparent width only

Evidence · table

“0.034”

Context: 22.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · silverGrade: 0.89Grade Unit: g/tIntercept: 22.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
silver
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
0.89
Grade Unit
g/t
Intercept
22.9 m
From
432.2 m
To
455.1 m
Intercept Depth
432.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:432.2-455.1
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The silver grade is very low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Grade is very low for silver
  • Apparent width only

Evidence · table

“0.89”

Context: 22.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-002Khaleesi · molybdenumGrade: 12Grade Unit: ppmIntercept: 22.9 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-002
Project
Khaleesi
Commodity
molybdenum
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
12
Grade Unit
ppm
Intercept
22.9 m
From
432.2 m
To
455.1 m
Intercept Depth
432.2 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-002:432.2-455.1
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
0.37
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: The molybdenum grade is low and not material on its own, but contributes to the overall polymetallic nature of the intercept.

Positive factors

  • Good intercept length
  • QA/QC disclosed

Negative factors

  • Molybdenum grade is low
  • Apparent width only

Evidence · table

“12”

Context: 22.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure, including certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“C3 Metals adheres to a strict QA/QC protocol for handling, sampling, sample transportation and analyses. ... ALS is an accredited laboratory ... High and low copper, gold and iron standards, as well as blanks and duplicates ... were randomly inserted into the sampling sequence for quality control. ... Stephen Hughes, P.Geo. is Vice President Exploration and a Director for C3 Metals and is a Qualified Person as defined by National Instrument 43-101. Mr. Hughes has reviewed the technical information in this news release and approves the written disclosure contained herein.”
KHZ5790-003Khaleesi · copperGrade: 1.05Grade Unit: %Intercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
KHZ5790-003
Project
Khaleesi
Commodity
copper
Region
peru
Reported Region
peru
Ticker
CCCM

Geometry

Grade
1.05
Grade Unit
%
Intercept
2.75 m
From
14.5 m
To
17.25 m
Intercept Depth
14.5 m

Classification

Deposit Type
skarn
Program
exploration
Sample Type
drill
Group ID
KHZ5790-003:14.5-17.25
Mining Method
unknown

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.23
Metal Eq. Unit
% CuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.15
Cutoff Unit
% Cu
Dilution Disclosed
Yes
Max Dilution
12 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-04-29T00:00:00.000Z

Reasoning: This copper intercept shows a strong grade near surface, but its narrow length limits its overall materiality.

Positive factors

  • Strong copper grade
  • Near-surface intercept
  • QA/QC disclosed

Negative factors

  • Narrow intercept length
  • Apparent width only

Evidence · table

“1.05”

Context: 2.75

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation.

Evidence · text

“All intervals reported in this table are down hole core lengths, and true thicknesses have yet to be determined.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.