Canada Nickel Reports Additional Exploration Drilling Results and Highest Grade Intervals to Date at Reid Nickel Sulphide Project

Original announcement by tmx on

Company
Canada Nickel Company Inc.
Ticker
CNC
Exchange
TSX
Region
Ontario
Primary commodity
Nickel
Secondary commodities
Cobalt, Palladium, Platinum, Chromium, Iron ore, Sulfur
Document categories
Drill results, Resource update
Extracted
2026-09-13 18:35:05 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Canada Nickel has reported its highest-grade nickel intercepts to date at the Reid Nickel Sulphide Project, including 1.01% Ni over 4.5 metres. The drilling is part of an infill program designed to convert existing inferred and indicated resources into higher confidence categories.

Reasoning: The release reports record-high grade nickel intercepts at the Reid project, which are part of an infill program intended to upgrade resource confidence.

Positive factors

  • Highest grade nickel intervals reported to date (1.01% Ni)
  • Significant width of high-grade mineralization (43.5m at 0.54% Ni)
  • QA/QC protocols and certified lab (Actlabs) disclosed
  • Infill drilling program aims to upgrade resource categories

Negative factors

  • True width undetermined for reported intervals

Facts used in scoring: 35

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 1.01% Ni is exceptionally high for a nickel sulphide project of this type.

Evidence · text

“1.01% nickel over 4.5 metres”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release details Actlabs Timmins (ISO/IEC 17025 accredited) and use of standards and blanks.

Evidence · text

“Activation Laboratories is an ISO/IEC 17025 accredited lab.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states 'True width undetermined' for the reported intervals.

Evidence · text

“*True width undetermined.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The program purpose is stated as infilling previous drill sections.

Evidence · text

“purpose of infilling previous drill sections”

Extracted facts

Stored fact records: 35. Some facts used in scoring do not have a stored record.

Drill Results (35)

REI26-90BReid · nickelGrade: 0.26Grade Unit: %Intercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
nickel
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.26
Grade Unit
%
Intercept
801.4 m
From
41.6 m
To
843 m
Hole Depth
876 m
Intercept Depth
41.6 m

Classification

Program
resource
Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

Location

Easting
456960
Northing
5404100
Azimuth
190 °
Dip
-68 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Routine low-grade intercept in a large mineralized zone.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

REI26-90BReid · cobaltGrade: 0.011Grade Unit: %Intercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
cobalt
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.011
Grade Unit
%
Intercept
801.4 m
From
41.6 m
To
843 m
Hole Depth
876 m
Intercept Depth
41.6 m

Classification

Program
resource
Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

Location

Easting
456960
Northing
5404100
Azimuth
190 °
Dip
-68 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Trace cobalt reported alongside nickel.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

REI26-92AReid · nickelGrade: 0.29Grade Unit: %Intercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
nickel
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.29
Grade Unit
%
Intercept
576.6 m
From
26.4 m
To
603 m
Hole Depth
603 m
Intercept Depth
26.4 m

Classification

Program
resource
Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

Location

Easting
457200
Northing
5404096
Azimuth
180 °
Dip
-82 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Significant width of mineralization, though true width is undetermined.

Negative factors

  • Apparent width only

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

REI26-92AReid · nickelGrade: 0.33Grade Unit: %Intercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
nickel
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.33
Grade Unit
%
Intercept
221.6 m
From
381.4 m
To
603 m
Hole Depth
603 m
Intercept Depth
381.4 m

Classification

Program
resource
Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

Location

Easting
457200
Northing
5404096
Azimuth
180 °
Dip
-82 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: High-grade sub-interval within the main intercept.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

REI26-92AReid · nickelGrade: 0.54Grade Unit: %Intercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
nickel
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.54
Grade Unit
%
Intercept
43.5 m
From
510 m
To
553.5 m
Hole Depth
603 m
Intercept Depth
510 m

Classification

Program
resource
Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

Location

Easting
457200
Northing
5404096
Azimuth
180 °
Dip
-82 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Strong grade and significant width.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

REI26-92AReid · nickelGrade: 1.01Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
nickel
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
1.01
Grade Unit
%
Intercept
4.5 m
From
511.5 m
To
516 m
Hole Depth
603 m
Intercept Depth
511.5 m

Classification

Program
resource
Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

Location

Easting
457200
Northing
5404096
Azimuth
180 °
Dip
-82 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Highest grade nickel interval reported to date.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

REI26-90BReid · palladiumGrade: 0.003Grade Unit: g/tIntercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
palladium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.003
Grade Unit
g/t
Intercept
801.4 m
From
41.6 m
To
843 m
Intercept Depth
41.6 m

Classification

Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.003 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for palladium; intercept not scored.

Evidence · table

“0.003”

Context: REI26-90B

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-90BReid · platinumGrade: 0.004Grade Unit: g/tIntercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
platinum
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.004
Grade Unit
g/t
Intercept
801.4 m
From
41.6 m
To
843 m
Intercept Depth
41.6 m

Classification

Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.004 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for platinum; intercept not scored.

Evidence · table

“0.004”

Context: REI26-90B

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-90BReid · chromiumGrade: 0.78Grade Unit: %Intercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
chromium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.78
Grade Unit
%
Intercept
801.4 m
From
41.6 m
To
843 m
Intercept Depth
41.6 m

Classification

Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.78 % chromium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for chromium; intercept not scored.

Evidence · table

“0.78”

Context: REI26-90B

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-90BReid · iron_oreGrade: 5.45Grade Unit: %Intercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
iron_ore
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
5.45
Grade Unit
%
Intercept
801.4 m
From
41.6 m
To
843 m
Intercept Depth
41.6 m

Classification

Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 5.45 % iron_ore. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for iron_ore; intercept not scored.

Evidence · table

“5.45”

Context: REI26-90B

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-90BReid · sulfurGrade: 0.028Grade Unit: %Intercept: 801.4 mView all details
Link to this fact

Identity

Hole ID
REI26-90B
Project
Reid
Commodity
sulfur
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.028
Grade Unit
%
Intercept
801.4 m
From
41.6 m
To
843 m
Intercept Depth
41.6 m

Classification

Sample Type
drill
Group ID
REI26-90B:41.6-843
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.028 % sulfur. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for sulfur; intercept not scored.

Evidence · table

“0.028”

Context: REI26-90B

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · cobaltGrade: 0.013Grade Unit: %Intercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
cobalt
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.013
Grade Unit
%
Intercept
576.6 m
From
26.4 m
To
603 m
Intercept Depth
26.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table. 0.013 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.

Negative factors

  • 0.013 % cobalt is below the weak threshold (0.08 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.013”

Context: REI26-92A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · palladiumGrade: 0.024Grade Unit: g/tIntercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
palladium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.024
Grade Unit
g/t
Intercept
576.6 m
From
26.4 m
To
603 m
Intercept Depth
26.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.024 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for palladium; intercept not scored.

Evidence · table

“0.024”

Context: REI26-92A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · platinumGrade: 0.016Grade Unit: g/tIntercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
platinum
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.016
Grade Unit
g/t
Intercept
576.6 m
From
26.4 m
To
603 m
Intercept Depth
26.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.016 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for platinum; intercept not scored.

Evidence · table

“0.016”

Context: REI26-92A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · chromiumGrade: 0.69Grade Unit: %Intercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
chromium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.69
Grade Unit
%
Intercept
576.6 m
From
26.4 m
To
603 m
Intercept Depth
26.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.69 % chromium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for chromium; intercept not scored.

Evidence · table

“0.69”

Context: REI26-92A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · iron_oreGrade: 5.75Grade Unit: %Intercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
iron_ore
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
5.75
Grade Unit
%
Intercept
576.6 m
From
26.4 m
To
603 m
Intercept Depth
26.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 5.75 % iron_ore. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for iron_ore; intercept not scored.

Evidence · table

“5.75”

Context: REI26-92A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · sulfurGrade: 0.058Grade Unit: %Intercept: 576.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
sulfur
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.058
Grade Unit
%
Intercept
576.6 m
From
26.4 m
To
603 m
Intercept Depth
26.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:26.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.058 % sulfur. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for sulfur; intercept not scored.

Evidence · table

“0.058”

Context: REI26-92A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · cobaltGrade: 0.015Grade Unit: %Intercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
cobalt
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.015
Grade Unit
%
Intercept
221.6 m
From
381.4 m
To
603 m
Intercept Depth
381.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table. 0.015 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.

Negative factors

  • 0.015 % cobalt is below the weak threshold (0.08 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.015”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · palladiumGrade: 0.053Grade Unit: g/tIntercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
palladium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.053
Grade Unit
g/t
Intercept
221.6 m
From
381.4 m
To
603 m
Intercept Depth
381.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.053 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for palladium; intercept not scored.

Evidence · table

“0.053”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · platinumGrade: 0.036Grade Unit: g/tIntercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
platinum
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.036
Grade Unit
g/t
Intercept
221.6 m
From
381.4 m
To
603 m
Intercept Depth
381.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.036 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for platinum; intercept not scored.

Evidence · table

“0.036”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · chromiumGrade: 0.65Grade Unit: %Intercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
chromium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.65
Grade Unit
%
Intercept
221.6 m
From
381.4 m
To
603 m
Intercept Depth
381.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.65 % chromium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for chromium; intercept not scored.

Evidence · table

“0.65”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · iron_oreGrade: 6.01Grade Unit: %Intercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
iron_ore
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
6.01
Grade Unit
%
Intercept
221.6 m
From
381.4 m
To
603 m
Intercept Depth
381.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 6.01 % iron_ore. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for iron_ore; intercept not scored.

Evidence · table

“6.01”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · sulfurGrade: 0.104Grade Unit: %Intercept: 221.6 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
sulfur
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.104
Grade Unit
%
Intercept
221.6 m
From
381.4 m
To
603 m
Intercept Depth
381.4 m

Classification

Sample Type
drill
Group ID
REI26-92A:381.4-603
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.104 % sulfur. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for sulfur; intercept not scored.

Evidence · table

“0.104”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · cobaltGrade: 0.017Grade Unit: %Intercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
cobalt
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.017
Grade Unit
%
Intercept
43.5 m
From
510 m
To
553.5 m
Intercept Depth
510 m

Classification

Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table. 0.017 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.

Negative factors

  • 0.017 % cobalt is below the weak threshold (0.08 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.017”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · palladiumGrade: 0.174Grade Unit: g/tIntercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
palladium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.174
Grade Unit
g/t
Intercept
43.5 m
From
510 m
To
553.5 m
Intercept Depth
510 m

Classification

Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.174 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for palladium; intercept not scored.

Evidence · table

“0.174”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · platinumGrade: 0.113Grade Unit: g/tIntercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
platinum
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.113
Grade Unit
g/t
Intercept
43.5 m
From
510 m
To
553.5 m
Intercept Depth
510 m

Classification

Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.113 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for platinum; intercept not scored.

Evidence · table

“0.113”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · chromiumGrade: 0.63Grade Unit: %Intercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
chromium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.63
Grade Unit
%
Intercept
43.5 m
From
510 m
To
553.5 m
Intercept Depth
510 m

Classification

Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.63 % chromium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for chromium; intercept not scored.

Evidence · table

“0.63”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · iron_oreGrade: 6.17Grade Unit: %Intercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
iron_ore
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
6.17
Grade Unit
%
Intercept
43.5 m
From
510 m
To
553.5 m
Intercept Depth
510 m

Classification

Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 6.17 % iron_ore. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for iron_ore; intercept not scored.

Evidence · table

“6.17”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · sulfurGrade: 0.205Grade Unit: %Intercept: 43.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
sulfur
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.205
Grade Unit
%
Intercept
43.5 m
From
510 m
To
553.5 m
Intercept Depth
510 m

Classification

Sample Type
drill
Group ID
REI26-92A:510-553.5
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.205 % sulfur. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for sulfur; intercept not scored.

Evidence · table

“0.205”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · cobaltGrade: 0.018Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
cobalt
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.018
Grade Unit
%
Intercept
4.5 m
From
511.5 m
To
516 m
Intercept Depth
511.5 m

Classification

Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table. 0.018 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.

Negative factors

  • 0.018 % cobalt is below the weak threshold (0.08 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.018”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · palladiumGrade: 0.071Grade Unit: g/tIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
palladium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.071
Grade Unit
g/t
Intercept
4.5 m
From
511.5 m
To
516 m
Intercept Depth
511.5 m

Classification

Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.071 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for palladium; intercept not scored.

Evidence · table

“0.071”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · platinumGrade: 0.038Grade Unit: g/tIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
platinum
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.038
Grade Unit
g/t
Intercept
4.5 m
From
511.5 m
To
516 m
Intercept Depth
511.5 m

Classification

Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.038 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for platinum; intercept not scored.

Evidence · table

“0.038”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · chromiumGrade: 0.61Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
chromium
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.61
Grade Unit
%
Intercept
4.5 m
From
511.5 m
To
516 m
Intercept Depth
511.5 m

Classification

Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.61 % chromium. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for chromium; intercept not scored.

Evidence · table

“0.61”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · iron_oreGrade: 6.39Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
iron_ore
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
6.39
Grade Unit
%
Intercept
4.5 m
From
511.5 m
To
516 m
Intercept Depth
511.5 m

Classification

Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 6.39 % iron_ore. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for iron_ore; intercept not scored.

Evidence · table

“6.39”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

REI26-92AReid · sulfurGrade: 0.35Grade Unit: %Intercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
REI26-92A
Project
Reid
Commodity
sulfur
Region
canada_on
Reported Region
canada_on
Ticker
CNC

Geometry

Grade
0.35
Grade Unit
%
Intercept
4.5 m
From
511.5 m
To
516 m
Intercept Depth
511.5 m

Classification

Sample Type
drill
Group ID
REI26-92A:511.5-516
Mining Method
unknown

QA/QC

Laboratory
Actlabs Timmins
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-08-06T00:00:00.000Z

Reasoning: Expanded from assay table: 0.35 % sulfur. No grade band defined for this commodity, so the score is a placeholder.

Negative factors

  • No grade rubric for sulfur; intercept not scored.

Evidence · table

“0.350”

Context: including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.