# Coppernico Channel Samples Intersect 70.1 m of 0.92% Copper and 0.25 g/t Gold at Nioc

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6

Original source: https://money.tmx.com/en/quote/COPR/news/6347962106599165/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at-

Publisher: tmx

Original announcement: 2026-05-19T11:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Coppernico Metals Inc.

- Ticker: COPR

- Exchange: TSX

- Region: Peru

- Primary commodity: Copper

- Secondary commodities: Gold, Silver

- Document categories: Drill results, Other

- Extracted: 2026-09-13 18:48:30 UTC

Narrative sentiment: 0.70 · Bullish

## Minestarters Atlas summary

Coppernico Metals has reported new surface channel sampling results at the Nioc target of its Sombrero Project in Peru. The results include a 70.1 m intercept of 0.92% Cu and 0.25 g/t Au, effectively doubling the known east-west width of mineralization at Zone 2 and demonstrating northward step-out extension.

Reasoning: The results demonstrate a significant northward expansion and doubling of the known surface width of mineralization at the Nioc target, although these are surface channel samples and true width is not stated.

- Positive factor: Step-Out Extension

- Positive factor: continuous high-grade skarn mineralization

- Positive factor: doubling of surface width

- Negative factor: Apparent Width Only

Facts used in scoring: 19

## Classification and evidence

**Step-Out Extension**

Polarity: positive

Definition: Mineralization extended beyond the previously known limit.

Why it applies: Channel 26SRT-111 is located 120m north of the combined line, demonstrating northward expansion.

Evidence · text

> demonstrating a meaningful northward expansion of the Zone 2 footprint

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: Release details QA/QC protocols including standards, blanks, and duplicates.

Evidence · text

> QA/QC programs for 2025-2026 channel samples included internal standard samples, blanks, and duplicates

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Table notes explicitly state that true thickness is unknown.

Evidence · text

> True thickness is unknown

## Extracted facts

Stored fact records: 19. Some facts used in scoring do not have a stored record.

## Drill Results (19)

### Combined 26SRT-109 / 25SRT-042 / 26SRT-110

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-0)

Sombrero Project · copper

#### Identity

- Hole ID: Combined 26SRT-109 / 25SRT-042 / 26SRT-110
- Project: Sombrero Project
- Commodity: copper
- Region: peru
- Reported Region: Peru
- Ticker: COPR

#### Geometry

- Grade: 0.92
- Grade Unit: %
- Intercept: 70.1 m
- Intercept Depth: 0 m

#### Classification

- Program: exploration
- Sample Type: channel
- Group ID: Combined 26SRT-109 / 25SRT-042 / 26SRT-110:0.0-70.1

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Cutoff Grade: 0.2
- Cutoff Unit: % Cu
- Dilution Disclosed: Yes
- Max Dilution: 6 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Significant width and grade for surface channel sampling, though true width is unknown.

- Positive factor: continuous mineralization

- Negative factor: Apparent Width Only

Evidence · table

> 0.92

Context: 70.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

### Combined 26SRT-109 / 25SRT-042 / 26SRT-110

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-1)

Sombrero Project · gold

#### Identity

- Hole ID: Combined 26SRT-109 / 25SRT-042 / 26SRT-110
- Project: Sombrero Project
- Commodity: gold
- Region: peru
- Reported Region: Peru
- Ticker: COPR

#### Geometry

- Grade: 0.25
- Grade Unit: g/t
- Intercept: 70.1 m
- Intercept Depth: 0 m

#### Classification

- Program: exploration
- Sample Type: channel
- Group ID: Combined 26SRT-109 / 25SRT-042 / 26SRT-110:0.0-70.1

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Cutoff Grade: 0.2
- Cutoff Unit: % Cu
- Dilution Disclosed: Yes
- Max Dilution: 6 m

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Gold grade is modest but part of a significant polymetallic intercept.

Evidence · table

> 0.25

Context: 70.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

### Combined 26SRT-109 / 25SRT-042 / 26SRT-110

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-2)

Sombrero Project · silver

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Combined 26SRT-109 / 25SRT-042 / 26SRT-110
- Project: Sombrero Project
- Commodity: silver
- Region: peru
- Reported Region: Peru
- Ticker: COPR

#### Geometry

- Grade: 2.45
- Grade Unit: g/t
- Intercept: 70.1 m
- Intercept Depth: 0 m

#### Classification

- Program: exploration
- Sample Type: channel
- Group ID: Combined 26SRT-109 / 25SRT-042 / 26SRT-110:0.0-70.1

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Cutoff Grade: 0.2
- Cutoff Unit: % Cu
- Dilution Disclosed: Yes
- Max Dilution: 6 m

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Silver is a minor byproduct in this intercept.

Evidence · table

> 2.45

Context: 70.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Compositing Transparent**

Polarity: positive

Definition: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff\_grade and internal dilution are both stated

### 25SRT-042

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-3)

Sombrero Project · copper

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: 25SRT-042
- Project: Sombrero Project
- Commodity: copper
- Region: peru
- Reported Region: Peru
- Ticker: COPR

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 36 m
- Intercept Depth: 0 m

#### Classification

- Program: exploration
- Sample Type: channel

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: High grade intercept, but previously reported in September 2025.

- Negative factor: Stale Data Re-release

Evidence · table

> 1.10

Context: 36.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

### 26SRT-111

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-4)

Sombrero Project · copper

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: 26SRT-111
- Project: Sombrero Project
- Commodity: copper
- Region: peru
- Reported Region: Peru
- Ticker: COPR

#### Geometry

- Grade: 0.58
- Grade Unit: %
- Intercept: 58 m
- Intercept Depth: 0 m

#### Classification

- Program: exploration
- Sample Type: channel

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Demonstrates meaningful northward expansion of the Zone 2 footprint.

- Positive factor: Step-Out Extension

Evidence · table

> 0.58

Context: 58.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 25SRT-042\*

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-5)

Sombrero · copper

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Incl. 25SRT-042\*
- Project: Sombrero
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 36 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 39.6 %·m is weak \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.1 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Incl. 25SRT-042\*

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 25SRT-042\*

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-6)

Sombrero · gold

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Incl. 25SRT-042\*
- Project: Sombrero
- Commodity: gold
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.32
- Grade Unit: g/t
- Intercept: 36 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 11.5 g/t·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Incl. 25SRT-042\*

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 25SRT-042\*

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-7)

Sombrero · silver

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Incl. 25SRT-042\*
- Project: Sombrero
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 3.44
- Grade Unit: g/t
- Intercept: 36 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 3.44 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 123.8 g/t·m is below.

- Negative factor: 3.44 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.44

Context: Incl. 25SRT-042\*

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 26SRT-109

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-8)

Sombrero · copper

#### Identity

- Hole ID: Incl. 26SRT-109
- Project: Sombrero
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 29 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 % copper is moderate against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 20.3 %·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.70

Context: Incl. 26SRT-109

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 26SRT-109

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-9)

Sombrero · gold

#### Identity

- Hole ID: Incl. 26SRT-109
- Project: Sombrero
- Commodity: gold
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.14
- Grade Unit: g/t
- Intercept: 29 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 4.1 g/t·m is below.

- Negative factor: 0.14 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Incl. 26SRT-109

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 26SRT-109

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-10)

Sombrero · silver

#### Identity

- Hole ID: Incl. 26SRT-109
- Project: Sombrero
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 1.22
- Grade Unit: g/t
- Intercept: 29 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 1.22 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 35.4 g/t·m is below.

- Negative factor: 1.22 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.22

Context: Incl. 26SRT-109

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 26SRT-110

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-11)

Sombrero · copper

#### Identity

- Hole ID: Incl. 26SRT-110
- Project: Sombrero
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.77
- Grade Unit: %
- Intercept: 5.1 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.77 % copper is moderate against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 3.9 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.77

Context: Incl. 26SRT-110

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 26SRT-110

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-12)

Sombrero · gold

#### Identity

- Hole ID: Incl. 26SRT-110
- Project: Sombrero
- Commodity: gold
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.27
- Grade Unit: g/t
- Intercept: 5.1 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 0.27 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Incl. 26SRT-110

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl. 26SRT-110

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-13)

Sombrero · silver

#### Identity

- Hole ID: Incl. 26SRT-110
- Project: Sombrero
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 1.52
- Grade Unit: g/t
- Intercept: 5.1 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 1.52 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 7.8 g/t·m is below.

- Negative factor: 1.52 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.52

Context: Incl. 26SRT-110

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### 26SRT-111

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-14)

Sombrero · gold

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: 26SRT-111
- Project: Sombrero
- Commodity: gold
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.39
- Grade Unit: g/t
- Intercept: 58 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 22.6 g/t·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.39

Context: 26SRT-111

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### 26SRT-111

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-15)

Sombrero · silver

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: 26SRT-111
- Project: Sombrero
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 58 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 98.6 g/t·m is below.

- Negative factor: 1.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.70

Context: 26SRT-111

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-16)

Sombrero · copper

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Incl.
- Project: Sombrero
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 38 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % copper is moderate against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 22.8 %·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.60

Context: Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-17)

Sombrero · gold

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Incl.
- Project: Sombrero
- Commodity: gold
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 0.55
- Grade Unit: g/t
- Intercept: 38 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 0.55 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 20.9 g/t·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.55

Context: Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/coppernico-channel-samples-intersect-70-1-m-of-0-92-copper-and-0-25-g-t-gold-at--4162c340-7dee-452f-91ff-d506196e94e6#fact-drill-facts-18)

Sombrero · silver

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: Incl.
- Project: Sombrero
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: COPR

#### Geometry

- Grade: 2.04
- Grade Unit: g/t
- Intercept: 38 m

#### Classification

- Sample Type: drill

#### QA/QC

- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Compositing

- Dilution Disclosed: Yes

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2025-09-04T00:00:00.000Z

#### Dates

- Event date: 2026-05-19T00:00:00.000Z

Reasoning: Expanded from assay table. 2.04 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 77.5 g/t·m is below.

- Negative factor: 2.04 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.04

Context: Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
