EdgarFiling

Original announcement by research on

Company
Fury Gold Mines Limited
Ticker
FURY
Exchange
TSX
Region
Northern Quebec
Primary commodity
Gold
Secondary commodities
None reported
Document categories
Drill results, Other
Extracted
2026-11-09 15:56:01 UTC

Analysis by Minestarters Atlas

Atlas analysis published:

Minestarters Atlas analysis

Summary

Fury reported final Phase 1 and initial Phase 2 drill results from the Eau Claire gold project in northern Quebec. Highlights include 7.86 g/t gold over 9.43 m in hole 26EC-103 and 13.83 g/t gold over 1.97 m in hole 26EC-102, with true thicknesses stated in the table. The release says the ongoing Phase 2 program is aimed at infill and upgrading inferred resources to indicated while improving continuity.

Reasoning: The release reports multiple new gold intercepts at Eau Claire, including a strong 7.86 g/t over 9.43 m interval and a very high-grade 13.83 g/t over 1.97 m interval, with true thicknesses and QA/QC disclosed. The program is mainly resource conversion/infill, so the results are positive but not fully transformative.

Positive factors

  • reported 7.86 g/t gold over 9.43 m
  • includes higher-grade intercept of 13.83 g/t over 1.97 m
  • true thickness disclosed in table
  • phase 2 designed to infill and upgrade inferred resources to indicated
  • QA/QC and qualified person disclosure provided

Negative factors

  • one hole reported no significant intercept
  • phase 2 results are part of an ongoing program, so novelty is not full
  • intercepts are from drill widths rather than resource estimate or economic study

Facts used in scoring: 11

Classification and evidence

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The table reports both drilled thickness and TRUE Thickness (m) for each intercept.

Evidence · text

“TRUE Thickness (m)”

Context: Table 1: Recent Drill Highlights

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: The release states the QA/QC program used standards, blanks, field and lab duplicates, and lab standards.

Evidence · text

“QA/QC programs using internal standard samples and blanks, field and lab duplicates, and lab standards and blanks”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: The release states the intercept calculation rules and maximum consecutive dilution.

Evidence · text

“Intercepts were calculated using Au grade*thickness no less than 2g/t*m with grade no less than 1g/t, maximum consecutive dilution 2m.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: Phase 2 is described as aimed at converting inferred mineral resources into higher-confidence categories.

Evidence · text

“converting inferred mineral resources into higher-confidence categories”

Extracted facts

Stored fact records: 11. Some facts used in scoring do not have a stored record.

Drill Results (11)

26EC-102Eau Claire · goldGrade: 2.34Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
26EC-102
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
2.34
Grade Unit
g/t
Intercept
1.5 m
True Width
1.49 m
From
507 m
To
508.5 m
Intercept Depth
507 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-102:507.0-508.5
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: A 2.34 g/t gold intercept over 1.5 m is a modest but meaningful result within an underground-style gold system, and the true width is stated.

Positive factors

  • true thickness disclosed
  • meets stated 1 g/t cut-off and 2 g/t·m threshold
  • part of resource continuity work

Negative factors

  • short intercept width
  • not the strongest result in the release

Evidence · table

“2.34”

Context: 26EC-102 | 507.0 | 508.5 | 1.5 | 1.49 | 2.34 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.49

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-102Eau Claire · goldGrade: 13.83Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26EC-102
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
13.83
Grade Unit
g/t
Intercept
2 m
True Width
1.97 m
From
568.5 m
To
570.5 m
Intercept Depth
507 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-102:568.5-570.5
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 13.83 g/t gold intercept over 2.0 m is a high-grade result with true thickness disclosed, making it one of the strongest assays in the release.

Positive factors

  • very high grade gold intercept
  • true thickness disclosed
  • well above stated cut-off and GT threshold

Negative factors

  • short width limits bulk tonnage impact

Evidence · table

“13.83”

Context: 26EC-102 | 568.5 | 570.5 | 2.0 | 1.97 | 13.83 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.97

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-102Eau Claire · goldGrade: 4.23Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26EC-102
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
4.23
Grade Unit
g/t
Intercept
1 m
True Width
0.98 m
From
587 m
To
588 m
Intercept Depth
507 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-102:587.0-588.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 4.23 g/t gold result over 1.0 m is a solid high-grade intercept, though narrow.

Positive factors

  • grade above strong threshold for underground gold is still encouraging
  • true thickness disclosed

Negative factors

  • narrow intercept

Evidence · table

“4.23”

Context: 26EC-102 | 587.0 | 588.0 | 1.0 | 0.98 | 4.23 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.98

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-102Eau Claire · goldGrade: 2.15Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26EC-102
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
2.15
Grade Unit
g/t
Intercept
1 m
True Width
0.98 m
From
612 m
To
613 m
Intercept Depth
507 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-102:612.0-613.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: This is a moderate gold intercept that supports continuity but is less material than the higher-grade intervals in the release.

Positive factors

  • above 2 g/t threshold
  • true thickness disclosed

Negative factors

  • short intercept width

Evidence · table

“2.15”

Context: 26EC-102 | 612.0 | 613.0 | 1.0 | 0.98 | 2.15 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.98

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-102Eau Claire · goldGrade: 2.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26EC-102
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
2.1
Grade Unit
g/t
Intercept
1 m
True Width
0.97 m
From
780.5 m
To
781.5 m
Intercept Depth
507 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-102:780.5-781.5
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 2.10 g/t gold intercept over 1.0 m is positive but relatively modest.

Positive factors

  • above 2 g/t threshold
  • true thickness disclosed

Negative factors

  • narrow intercept

Evidence · table

“2.10”

Context: 26EC-102 | 780.5 | 781.5 | 1.0 | 0.97 | 2.10 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.97

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-103Eau Claire · goldGrade: 2.76Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26EC-103
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
2.76
Grade Unit
g/t
Intercept
1 m
True Width
0.99 m
From
294 m
To
295 m
Intercept Depth
294 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-103:294.0-295.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 2.76 g/t gold intercept over 1.0 m is a moderate result that still contributes to continuity.

Positive factors

  • above threshold for underground gold
  • true thickness disclosed

Negative factors

  • short width

Evidence · table

“2.76”

Context: 26EC-103 | 294.0 | 295.0 | 1.0 | 0.99 | 2.76 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.99

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-103Eau Claire · goldGrade: 7.86Grade Unit: g/tIntercept: 9.5 mView all details
Link to this fact

Identity

Hole ID
26EC-103
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
7.86
Grade Unit
g/t
Intercept
9.5 m
True Width
9.43 m
From
367.5 m
To
377 m
Intercept Depth
294 m

Classification

Deposit Type
orogenic
Program
mixed
Sample Type
drill
Group ID
26EC-103:367.5-377.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 7.86 g/t gold intercept over 9.43 m is the standout result in the release and materially supports continuity in the deposit.

Positive factors

  • strong grade over a meaningful width
  • true thickness disclosed
  • described as the most significant result
  • supports continuity within the modelled zone

Evidence · table

“7.86”

Context: 26EC-103 | 367.5 | 377.0 | 9.5 | 9.43 | 7.86 | Expansion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.43

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

26EC-107Eau Claire · goldGrade: 1.6Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
26EC-107
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
1.6
Grade Unit
g/t
Intercept
1.5 m
True Width
1.41 m
From
91.5 m
To
93 m
Intercept Depth
91.5 m

Classification

Deposit Type
orogenic
Program
resource
Sample Type
drill
Group ID
26EC-107:91.5-93.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 1.60 g/t over 1.5 m intercept is modest and is mainly relevant for continuity in the conversion program.

Positive factors

  • true thickness disclosed
  • part of conversion drilling

Negative factors

  • low grade relative to other intervals

Evidence · table

“1.60”

Context: 26EC-107 | 91.5 | 93.0 | 1.5 | 1.41 | 1.60 | Conversion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.41

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

26EC-107Eau Claire · goldGrade: 34.2Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
26EC-107
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
34.2
Grade Unit
g/t
Intercept
1 m
True Width
0.96 m
From
412 m
To
413 m
Intercept Depth
91.5 m

Classification

Deposit Type
orogenic
Program
resource
Sample Type
drill
Group ID
26EC-107:412.0-413.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 34.20 g/t gold intercept over 1.0 m is an exceptional high-grade result, albeit over a narrow width.

Positive factors

  • exceptionally high grade
  • true thickness disclosed
  • supports resource conversion

Negative factors

  • narrow width

Evidence · table

“34.20”

Context: 26EC-107 | 412.0 | 413.0 | 1.0 | 0.96 | 34.20 | Conversion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.96

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

26EC-107Eau Claire · goldGrade: 9.17Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
26EC-107
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
9.17
Grade Unit
g/t
Intercept
2 m
True Width
1.93 m
From
429 m
To
431 m
Intercept Depth
91.5 m

Classification

Deposit Type
orogenic
Program
resource
Sample Type
drill
Group ID
26EC-107:429.0-431.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 9.17 g/t gold over 2.0 m intercept is a strong high-grade result and supports upgrading confidence in the mineralized zone.

Positive factors

  • very strong grade
  • true thickness disclosed
  • resource conversion context

Negative factors

  • short intercept width

Evidence · table

“9.17”

Context: 26EC-107 | 429.0 | 431.0 | 2.0 | 1.93 | 9.17 | Conversion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.93

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

26EC-107Eau Claire · goldGrade: 3.79Grade Unit: g/tIntercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
26EC-107
Project
Eau Claire
Commodity
gold
Region
canada_qc
Reported Region
canada_qc

Geometry

Grade
3.79
Grade Unit
g/t
Intercept
7.5 m
True Width
7.25 m
From
446.5 m
To
454 m
Intercept Depth
91.5 m

Classification

Deposit Type
orogenic
Program
resource
Sample Type
drill
Group ID
26EC-107:446.5-454.0
Mining Method
underground

Location

Location
Eau Claire
Loc. Source
document

QA/QC

Laboratory
ALS Chemex
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
1
Cutoff Unit
g/t
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Reasoning: The 3.79 g/t gold intercept over 7.5 m is a materially useful continuity result and is strong for an underground-style gold setting.

Positive factors

  • meaningful width with strong grade
  • true thickness disclosed
  • continuity-supporting result

Evidence · table

“3.79”

Context: 26EC-107 | 446.5 | 454.0 | 7.5 | 7.25 | 3.79 | Conversion

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.25

QA/QC Disclosedpositive

Reported assays have a certified laboratory, actual QA/QC methods, or named QP/CP responsibility. Generic CP boilerplate, old-release references, plans and unrelated work are insufficient. Approval of a correction does not verify expressly unverified historical assays; assay accuracy is not guaranteed.

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "resource"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.