Endeavour Silver Intersects High-Grade Silver and Gold Mineralization at its Terronera Operation

Original announcement by tmx on

Company
Endeavour Silver Corp.
Ticker
EDR
Exchange
TSX
Region
Jalisco, Mexico
Primary commodity
Silver
Secondary commodities
Gold
Document categories
Drill results
Extracted
2026-09-19 18:50:39 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Endeavour Silver announced high-grade silver and gold drill results from its Terronera operation in Jalisco, Mexico, extending mineralization at the La Luz and Terronera veins along strike and at depth. Key intercepts include 2,607 g/t AgEq over 1.06 meters true width in hole LL-43 and 686 g/t AgEq over 5.32 meters true width in hole TRU-003. The exploration program aims to support mine design, resource growth, and extend the mine life.

Reasoning: The drill results show high-grade silver and gold mineralization with good true widths, extending known veins at depth and along strike. The program is designed to support mine design and resource growth, indicating positive progress for the Terronera operation. QA/QC is well-disclosed.

Positive factors

  • High-grade silver and gold intercepts, particularly in LL-43 and LL-77, demonstrate strong mineralization.
  • Significant true widths reported for several intercepts, adding confidence to the continuity.
  • Drilling successfully extended mineralization along strike and at depth in both La Luz and Terronera veins.
  • QA/QC procedures are clearly disclosed, including certified labs and QP sign-off.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 118

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole LL-43 returned 23.92 g/t Au and 574 g/t Ag over 1.06 m true width, with an AgEq of 2,607 g/t, which is exceptionally high-grade for silver and gold.

Evidence · text

“LL-43: 574 g/t Ag, 23.92 g/t Au for 2,607 g/t AgEq over 1.06 metres true width”

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole LL-77 returned 0.81 g/t Au and 1,271 g/t Ag over 0.94 m true width, with an AgEq of 1,340 g/t, which is exceptionally high-grade for silver.

Evidence · text

“LL-77: 1,271 g/t Ag, 0.81 g/t Au for 1,340 g/t AgEq over 0.94 metres true width”

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The drill results tables explicitly provide 'True Width (m)' for all reported intercepts.

Evidence · table

“1.06”

Context: 1.30

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The news release details the QA/QC program, including certified laboratories (ALS and SGS) and the use of standards, blanks, and duplicates.

Evidence · text

“A quality control sampling program of reference standards, blanks and duplicates has been instituted to monitor the integrity of all assay results.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The program is designed to 'expand and better define mineralization along strike and at depth' and has 'successfully extended mineralization along strike and at depth'.

Evidence · text

“The program is designed to expand and better define mineralization along strike and at depth within the Terronera vein system.”

QP/CP Signedpositive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: Dale Mah, P.Geo., a qualified person under NI 43-101, has approved the scientific and technical information.

Evidence · text

“Dale Mah, P.Geo., Vice President Corporate Development, a qualified person under NI 43-101, has approved the scientific and technical information contained in this news release.”

Extracted facts

Stored fact records: 118. Some facts used in scoring do not have a stored record.

Drill Results (118)

LL-43Terronera Operation · goldGrade: 23.92Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
LL-43
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
23.92
Grade Unit
g/t
Intercept
1.3 m
True Width
1.06 m
From
104.1 m
To
105.4 m
Intercept Depth
104.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-43:104.1-105.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2607
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptionally high gold grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.

Positive factors

  • Exceptional gold grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“23.92”

Context: 1.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.06

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-43Terronera Operation · silverGrade: 574Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
LL-43
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
574
Grade Unit
g/t
Intercept
1.3 m
True Width
1.06 m
From
104.1 m
To
105.4 m
Intercept Depth
104.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-43:104.1-105.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2607
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptionally high silver grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.

Positive factors

  • Exceptional silver grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“574”

Context: 1.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.06

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-43Terronera Operation · goldGrade: 44.4Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
LL-43
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
44.4
Grade Unit
g/t
Intercept
0.7 m
True Width
0.57 m
From
104.7 m
To
105.4 m
Intercept Depth
104.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-43:104.7-105.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4834
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows an even higher gold grade, reinforcing the bonanza nature of the LL-43 intercept.

Positive factors

  • Exceptional gold grade within a high-grade zone.
  • True width reported.
  • Confirms very high-grade core within the broader intercept.

Evidence · table

“44.40”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-43Terronera Operation · silverGrade: 1060Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
LL-43
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1060
Grade Unit
g/t
Intercept
0.7 m
True Width
0.57 m
From
104.7 m
To
105.4 m
Intercept Depth
104.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-43:104.7-105.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4834
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows an even higher silver grade, reinforcing the bonanza nature of the LL-43 intercept.

Positive factors

  • Exceptional silver grade within a high-grade zone.
  • True width reported.
  • Confirms very high-grade core within the broader intercept.

Evidence · table

“1,060”

Context: 0.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-44Terronera Operation · goldGrade: 3.84Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
LL-44
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.84
Grade Unit
g/t
Intercept
2.95 m
True Width
2.26 m
From
120.1 m
To
123.05 m
Intercept Depth
120.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-44:120.1-123.05
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
503
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade over a good true width.
  • Part of a program extending mineralization.

Evidence · table

“3.84”

Context: 2.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.26

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-44Terronera Operation · silverGrade: 176Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
LL-44
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
176
Grade Unit
g/t
Intercept
2.95 m
True Width
2.26 m
From
120.1 m
To
123.05 m
Intercept Depth
120.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-44:120.1-123.05
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
503
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade over a good true width.
  • Part of a program extending mineralization.

Evidence · table

“176”

Context: 2.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.26

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-44Terronera Operation · goldGrade: 18.15Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
LL-44
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
18.15
Grade Unit
g/t
Intercept
0.45 m
True Width
0.34 m
From
122.6 m
To
123.05 m
Intercept Depth
122.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-44:122.6-123.05
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2360
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights a strong gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.

Positive factors

  • Strong gold grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“18.15”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-44Terronera Operation · silverGrade: 817Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
LL-44
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
817
Grade Unit
g/t
Intercept
0.45 m
True Width
0.34 m
From
122.6 m
To
123.05 m
Intercept Depth
122.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-44:122.6-123.05
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2360
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional silver grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.

Positive factors

  • Exceptional silver grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“817”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-48Terronera Operation · goldGrade: 1.08Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
LL-48
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.08
Grade Unit
g/t
Intercept
1.55 m
True Width
0.95 m
From
124.85 m
To
126.4 m
Intercept Depth
124.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-48:124.85-126.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
100
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a narrow true width, contributing to the overall understanding of the mineralization but not a highlight.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“1.08”

Context: 1.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-48Terronera Operation · silverGrade: 8Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
LL-48
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
8
Grade Unit
g/t
Intercept
1.55 m
True Width
0.95 m
From
124.85 m
To
126.4 m
Intercept Depth
124.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-48:124.85-126.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
100
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak silver grade, which is not particularly material, though true width is reported.

Positive factors

  • True width reported.

Negative factors

  • Weak silver grade.

Evidence · table

“8”

Context: 1.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.95

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-48Terronera Operation · goldGrade: 1.93Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
LL-48
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.93
Grade Unit
g/t
Intercept
0.85 m
True Width
0.52 m
From
125.55 m
To
126.4 m
Intercept Depth
125.55 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-48:125.55-126.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“1.93”

Context: 0.85

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-48Terronera Operation · silverGrade: 10Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
LL-48
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
10
Grade Unit
g/t
Intercept
0.85 m
True Width
0.52 m
From
125.55 m
To
126.4 m
Intercept Depth
125.55 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-48:125.55-126.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
173
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak silver grade, which is not particularly material, though true width is reported.

Positive factors

  • True width reported.

Negative factors

  • Weak silver grade.

Evidence · table

“10”

Context: 0.85

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-49Terronera Operation · goldGrade: 3.43Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
LL-49
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.43
Grade Unit
g/t
Intercept
1.35 m
True Width
1.3 m
From
77 m
To
78.35 m
Intercept Depth
77 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-49:77-78.35
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
871
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade over a good true width.
  • Part of a program extending mineralization.

Evidence · table

“3.43”

Context: 1.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-49Terronera Operation · silverGrade: 579Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
LL-49
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
579
Grade Unit
g/t
Intercept
1.35 m
True Width
1.3 m
From
77 m
To
78.35 m
Intercept Depth
77 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-49:77-78.35
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
871
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptional silver grade over a good true width, indicating strong mineralization.

Positive factors

  • Exceptional silver grade over a good true width.
  • Part of a program extending mineralization.

Evidence · table

“579”

Context: 1.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-49Terronera Operation · goldGrade: 4.47Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LL-49
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
4.47
Grade Unit
g/t
Intercept
1 m
True Width
0.93 m
From
77 m
To
78 m
Intercept Depth
77 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-49:77-78
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1121
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a good true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Moderate gold grade over a good true width.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“4.47”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.93

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-49Terronera Operation · silverGrade: 741Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LL-49
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
741
Grade Unit
g/t
Intercept
1 m
True Width
0.93 m
From
77 m
To
78 m
Intercept Depth
77 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-49:77-78
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1121
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional silver grade over a good true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Exceptional silver grade over a good true width.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“741”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.93

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-50Terronera Operation · goldGrade: 0.47Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
LL-50
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.47
Grade Unit
g/t
Intercept
1.25 m
True Width
1.2 m
From
78 m
To
79.25 m
Intercept Depth
78 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-50:78-79.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
120
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, which is not particularly material, though true width is reported.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.47”

Context: 1.25

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-50Terronera Operation · silverGrade: 80Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
LL-50
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
80
Grade Unit
g/t
Intercept
1.25 m
True Width
1.2 m
From
78 m
To
79.25 m
Intercept Depth
78 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-50:78-79.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
120
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • True width reported.

Evidence · table

“80”

Context: 1.25

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-50Terronera Operation · goldGrade: 0.86Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
LL-50
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.86
Grade Unit
g/t
Intercept
0.6 m
True Width
0.57 m
From
78 m
To
78.6 m
Intercept Depth
78 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-50:78-78.6
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
196
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“0.86”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-50Terronera Operation · silverGrade: 123Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
LL-50
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
123
Grade Unit
g/t
Intercept
0.6 m
True Width
0.57 m
From
78 m
To
78.6 m
Intercept Depth
78 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-50:78-78.6
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
196
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, improving slightly on the broader intercept.

Positive factors

  • Moderate silver grade.
  • True width reported.

Evidence · table

“123”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-51Terronera Operation · goldGrade: 1.99Grade Unit: g/tIntercept: 2.15 mView all details
Link to this fact

Identity

Hole ID
LL-51
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.99
Grade Unit
g/t
Intercept
2.15 m
True Width
0.94 m
From
139.1 m
To
141.25 m
Intercept Depth
139.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-51:139.1-141.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
196
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a narrow true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“1.99”

Context: 2.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.94

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-51Terronera Operation · silverGrade: 27Grade Unit: g/tIntercept: 2.15 mView all details
Link to this fact

Identity

Hole ID
LL-51
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
27
Grade Unit
g/t
Intercept
2.15 m
True Width
0.94 m
From
139.1 m
To
141.25 m
Intercept Depth
139.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-51:139.1-141.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
196
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak silver grade, which is not particularly material, though true width is reported.

Positive factors

  • True width reported.

Negative factors

  • Weak silver grade.

Evidence · table

“27”

Context: 2.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.94

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-51Terronera Operation · goldGrade: 3.75Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
LL-51
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.75
Grade Unit
g/t
Intercept
0.65 m
True Width
0.28 m
From
140.6 m
To
141.25 m
Intercept Depth
140.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-51:140.6-141.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
360
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, suggesting high-grade zones within the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“3.75”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-51Terronera Operation · silverGrade: 41Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
LL-51
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
41
Grade Unit
g/t
Intercept
0.65 m
True Width
0.28 m
From
140.6 m
To
141.25 m
Intercept Depth
140.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-51:140.6-141.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
360
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak silver grade over a narrow true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak silver grade.

Evidence · table

“41”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.28

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-52Terronera Operation · goldGrade: 15.86Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
LL-52
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
15.86
Grade Unit
g/t
Intercept
2.2 m
True Width
1.13 m
From
151.35 m
To
153.55 m
Intercept Depth
151.35 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-52:151.35-153.55
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1404
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptional gold grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.

Positive factors

  • Exceptional gold grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“15.86”

Context: 2.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.13

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-52Terronera Operation · silverGrade: 55Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
LL-52
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
55
Grade Unit
g/t
Intercept
2.2 m
True Width
1.13 m
From
151.35 m
To
153.55 m
Intercept Depth
151.35 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-52:151.35-153.55
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1404
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • True width reported.

Evidence · table

“55”

Context: 2.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.13

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-52Terronera Operation · goldGrade: 18.4Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
LL-52
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
18.4
Grade Unit
g/t
Intercept
0.9 m
True Width
0.46 m
From
152.65 m
To
153.55 m
Intercept Depth
152.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-52:152.65-153.55
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1640
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.

Positive factors

  • Exceptional gold grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“18.40”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.46

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-52Terronera Operation · silverGrade: 76Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
LL-52
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
76
Grade Unit
g/t
Intercept
0.9 m
True Width
0.46 m
From
152.65 m
To
153.55 m
Intercept Depth
152.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-52:152.65-153.55
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1640
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • True width reported.

Evidence · table

“76”

Context: 0.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.46

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-55Terronera Operation · goldGrade: 1.66Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
LL-55
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.66
Grade Unit
g/t
Intercept
1.6 m
True Width
1.31 m
From
84.5 m
To
86.1 m
Intercept Depth
84.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-55:84.5-86.1
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade.
  • Good true width reported.

Evidence · table

“1.66”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-55Terronera Operation · silverGrade: 19Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
LL-55
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
19
Grade Unit
g/t
Intercept
1.6 m
True Width
1.31 m
From
84.5 m
To
86.1 m
Intercept Depth
84.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-55:84.5-86.1
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
160
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak silver grade, which is not particularly material, though good true width is reported.

Positive factors

  • Good true width reported.

Negative factors

  • Weak silver grade.

Evidence · table

“19”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-55Terronera Operation · goldGrade: 2.77Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LL-55
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
2.77
Grade Unit
g/t
Intercept
0.95 m
True Width
0.78 m
From
85.15 m
To
86.1 m
Intercept Depth
85.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-55:85.15-86.1
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
266
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a good true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Moderate gold grade over a good true width.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“2.77”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.78

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-55Terronera Operation · silverGrade: 30Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LL-55
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
30
Grade Unit
g/t
Intercept
0.95 m
True Width
0.78 m
From
85.15 m
To
86.1 m
Intercept Depth
85.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-55:85.15-86.1
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
266
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, improving slightly on the broader intercept.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“30”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.78

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-59Terronera Operation · goldGrade: 7.47Grade Unit: g/tIntercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
LL-59
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
7.47
Grade Unit
g/t
Intercept
2.3 m
True Width
2.12 m
From
135.1 m
To
137.4 m
Intercept Depth
135.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-59:135.1-137.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1013
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade over a good true width, indicating significant mineralization and contributing positively to the project's potential.

Positive factors

  • Strong gold grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“7.47”

Context: 2.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.12

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-59Terronera Operation · silverGrade: 378Grade Unit: g/tIntercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
LL-59
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
378
Grade Unit
g/t
Intercept
2.3 m
True Width
2.12 m
From
135.1 m
To
137.4 m
Intercept Depth
135.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-59:135.1-137.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1013
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a good true width, indicating significant mineralization and contributing positively to the project's potential.

Positive factors

  • Strong silver grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“378”

Context: 2.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.12

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-59Terronera Operation · goldGrade: 17.9Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
LL-59
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
17.9
Grade Unit
g/t
Intercept
0.75 m
True Width
0.69 m
From
135.1 m
To
135.85 m
Intercept Depth
135.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-59:135.1-135.85
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1962
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.

Positive factors

  • Exceptional gold grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“17.90”

Context: 0.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.69

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-59Terronera Operation · silverGrade: 440Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
LL-59
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
440
Grade Unit
g/t
Intercept
0.75 m
True Width
0.69 m
From
135.1 m
To
135.85 m
Intercept Depth
135.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-59:135.1-135.85
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1962
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional silver grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.

Positive factors

  • Exceptional silver grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“440”

Context: 0.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.69

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-61Terronera Operation · goldGrade: 0.65Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
LL-61
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.65
Grade Unit
g/t
Intercept
2.2 m
True Width
2.07 m
From
138 m
To
140.2 m
Intercept Depth
138 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-61:138-140.2
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
148
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.65”

Context: 2.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.07

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-61Terronera Operation · silverGrade: 93Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
LL-61
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
93
Grade Unit
g/t
Intercept
2.2 m
True Width
2.07 m
From
138 m
To
140.2 m
Intercept Depth
138 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-61:138-140.2
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
148
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“93”

Context: 2.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.07

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-61Terronera Operation · goldGrade: 0.53Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
LL-61
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.53
Grade Unit
g/t
Intercept
0.45 m
True Width
0.42 m
From
139.75 m
To
140.2 m
Intercept Depth
139.75 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-61:139.75-140.2
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
278
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.53”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.42

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-61Terronera Operation · silverGrade: 233Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
LL-61
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
233
Grade Unit
g/t
Intercept
0.45 m
True Width
0.42 m
From
139.75 m
To
140.2 m
Intercept Depth
139.75 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-61:139.75-140.2
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
278
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, indicating a high-grade pocket.

Positive factors

  • Strong silver grade.
  • True width reported.

Evidence · table

“233”

Context: 0.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.42

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-63Terronera Operation · goldGrade: 0.65Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LL-63
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.65
Grade Unit
g/t
Intercept
0.95 m
True Width
0.86 m
From
155.65 m
To
156.6 m
Intercept Depth
155.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-63:155.65-156.6
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
481
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade over a good true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.65”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.86

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-63Terronera Operation · silverGrade: 426Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LL-63
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
426
Grade Unit
g/t
Intercept
0.95 m
True Width
0.86 m
From
155.65 m
To
156.6 m
Intercept Depth
155.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-63:155.65-156.6
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
481
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptional silver grade over a good true width, indicating strong mineralization.

Positive factors

  • Exceptional silver grade over a good true width.
  • Part of a program extending mineralization.

Evidence · table

“426”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.86

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-63Terronera Operation · goldGrade: 1.68Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
LL-63
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.68
Grade Unit
g/t
Intercept
0.35 m
True Width
0.32 m
From
155.65 m
To
156 m
Intercept Depth
155.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-63:155.65-156
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1287
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“1.68”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-63Terronera Operation · silverGrade: 1145Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
LL-63
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1145
Grade Unit
g/t
Intercept
0.35 m
True Width
0.32 m
From
155.65 m
To
156 m
Intercept Depth
155.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-63:155.65-156
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1287
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional silver grade, suggesting very high-grade zones within the broader intercept.

Positive factors

  • Exceptional silver grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“1,145”

Context: 0.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-67Terronera Operation · goldGrade: 2.01Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
LL-67
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
2.01
Grade Unit
g/t
Intercept
1.55 m
True Width
1.37 m
From
146.8 m
To
148.35 m
Intercept Depth
146.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-67:146.8-148.35
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
285
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade.
  • Good true width reported.

Evidence · table

“2.01”

Context: 1.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-67Terronera Operation · silverGrade: 115Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
LL-67
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
115
Grade Unit
g/t
Intercept
1.55 m
True Width
1.37 m
From
146.8 m
To
148.35 m
Intercept Depth
146.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-67:146.8-148.35
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
285
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“115”

Context: 1.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.37

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-67Terronera Operation · goldGrade: 4.62Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
LL-67
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
4.62
Grade Unit
g/t
Intercept
0.65 m
True Width
0.57 m
From
147 m
To
147.65 m
Intercept Depth
147 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-67:147-147.65
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
617
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a strong gold grade over a narrow true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Strong gold grade.
  • True width reported.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“4.62”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-67Terronera Operation · silverGrade: 224Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
LL-67
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
224
Grade Unit
g/t
Intercept
0.65 m
True Width
0.57 m
From
147 m
To
147.65 m
Intercept Depth
147 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-67:147-147.65
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
617
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Strong silver grade.
  • True width reported.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“224”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-68Terronera Operation · goldGrade: 1.12Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
LL-68
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.12
Grade Unit
g/t
Intercept
1.5 m
True Width
1.19 m
From
180.5 m
To
182 m
Intercept Depth
180.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-68:180.5-182
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
348
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade.
  • Good true width reported.

Evidence · table

“1.12”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.19

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-68Terronera Operation · silverGrade: 252.8Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
LL-68
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
252.8
Grade Unit
g/t
Intercept
1.5 m
True Width
1.19 m
From
180.5 m
To
182 m
Intercept Depth
180.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-68:180.5-182
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
348
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Strong silver grade.
  • Good true width reported.

Evidence · table

“252.8”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.19

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-68Terronera Operation · goldGrade: 1.55Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LL-68
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.55
Grade Unit
g/t
Intercept
1 m
True Width
0.79 m
From
180.5 m
To
181.5 m
Intercept Depth
180.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-68:180.5-181.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
461
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a good true width, improving slightly on the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“1.55”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.79

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-68Terronera Operation · silverGrade: 330Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LL-68
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
330
Grade Unit
g/t
Intercept
1 m
True Width
0.79 m
From
180.5 m
To
181.5 m
Intercept Depth
180.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-68:180.5-181.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
461
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a good true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Strong silver grade.
  • True width reported.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“330”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.79

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-69Terronera Operation · goldGrade: 0.31Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
LL-69
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.31
Grade Unit
g/t
Intercept
1.6 m
True Width
1.13 m
From
204.9 m
To
206.5 m
Intercept Depth
204.9 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-69:204.9-206.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.31”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.13

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-69Terronera Operation · silverGrade: 172Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
LL-69
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
172
Grade Unit
g/t
Intercept
1.6 m
True Width
1.13 m
From
204.9 m
To
206.5 m
Intercept Depth
204.9 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-69:204.9-206.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
198
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“172”

Context: 1.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.13

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-69Terronera Operation · goldGrade: 0.43Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
LL-69
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.43
Grade Unit
g/t
Intercept
0.8 m
True Width
0.57 m
From
205.7 m
To
206.5 m
Intercept Depth
205.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-69:205.7-206.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
280
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.43”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-69Terronera Operation · silverGrade: 243Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
LL-69
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
243
Grade Unit
g/t
Intercept
0.8 m
True Width
0.57 m
From
205.7 m
To
206.5 m
Intercept Depth
205.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-69:205.7-206.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
280
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, indicating a high-grade pocket.

Positive factors

  • Strong silver grade.
  • True width reported.

Evidence · table

“243”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.57

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-74Terronera Operation · goldGrade: 2.41Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
LL-74
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
2.41
Grade Unit
g/t
Intercept
1.7 m
True Width
1.5 m
From
130 m
To
131.7 m
Intercept Depth
130 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-74:130-131.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
354
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade.
  • Good true width reported.

Evidence · table

“2.41”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-74Terronera Operation · silverGrade: 149.5Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
LL-74
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
149.5
Grade Unit
g/t
Intercept
1.7 m
True Width
1.5 m
From
130 m
To
131.7 m
Intercept Depth
130 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-74:130-131.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
354
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“149.5”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-74Terronera Operation · goldGrade: 3.68Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
LL-74
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.68
Grade Unit
g/t
Intercept
0.85 m
True Width
0.75 m
From
130.85 m
To
131.7 m
Intercept Depth
130.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-74:130.85-131.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
417
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a good true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Moderate gold grade over a good true width.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“3.68”

Context: 0.85

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-74Terronera Operation · silverGrade: 104Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
LL-74
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
104
Grade Unit
g/t
Intercept
0.85 m
True Width
0.75 m
From
130.85 m
To
131.7 m
Intercept Depth
130.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-74:130.85-131.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
417
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, improving slightly on the broader intercept.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“104”

Context: 0.85

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.75

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-75Terronera Operation · goldGrade: 0.36Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
LL-75
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.36
Grade Unit
g/t
Intercept
1.9 m
True Width
1.41 m
From
174.55 m
To
176.45 m
Intercept Depth
174.55 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-75:174.55-176.45
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
262
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.

Positive factors

  • Good true width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.36”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.41

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-75Terronera Operation · silverGrade: 231Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
LL-75
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
231
Grade Unit
g/t
Intercept
1.9 m
True Width
1.41 m
From
174.55 m
To
176.45 m
Intercept Depth
174.55 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-75:174.55-176.45
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
262
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Strong silver grade.
  • Good true width reported.

Evidence · table

“231”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.41

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-75Terronera Operation · goldGrade: 0.44Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
LL-75
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.44
Grade Unit
g/t
Intercept
0.8 m
True Width
0.59 m
From
174.8 m
To
175.6 m
Intercept Depth
174.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-75:174.8-175.6
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
373
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.44”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.59

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-75Terronera Operation · silverGrade: 336Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
LL-75
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
336
Grade Unit
g/t
Intercept
0.8 m
True Width
0.59 m
From
174.8 m
To
175.6 m
Intercept Depth
174.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-75:174.8-175.6
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
373
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Strong silver grade.
  • True width reported.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“336”

Context: 0.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.59

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-76Terronera Operation · goldGrade: 0.26Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
LL-76
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.26
Grade Unit
g/t
Intercept
1.8 m
True Width
1.14 m
From
234 m
To
235.8 m
Intercept Depth
234 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-76:234-235.8
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
218
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.

Positive factors

  • Good true width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.26”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.14

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-76Terronera Operation · silverGrade: 195Grade Unit: g/tIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
LL-76
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
195
Grade Unit
g/t
Intercept
1.8 m
True Width
1.14 m
From
234 m
To
235.8 m
Intercept Depth
234 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-76:234-235.8
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
218
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“195”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.14

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-76Terronera Operation · goldGrade: 0.68Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
LL-76
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.68
Grade Unit
g/t
Intercept
0.65 m
True Width
0.41 m
From
235.15 m
To
235.8 m
Intercept Depth
235.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-76:235.15-235.8
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
570
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.68”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.41

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-76Terronera Operation · silverGrade: 512Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
LL-76
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
512
Grade Unit
g/t
Intercept
0.65 m
True Width
0.41 m
From
235.15 m
To
235.8 m
Intercept Depth
235.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-76:235.15-235.8
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
570
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional silver grade, suggesting high-grade zones within the broader intercept.

Positive factors

  • Exceptional silver grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“512”

Context: 0.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.41

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-77Terronera Operation · goldGrade: 0.81Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
LL-77
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.81
Grade Unit
g/t
Intercept
1.35 m
True Width
0.94 m
From
183.85 m
To
185.2 m
Intercept Depth
183.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-77:183.85-185.2
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1340
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade over a good true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.81”

Context: 1.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.94

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-77Terronera Operation · silverGrade: 1271Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
LL-77
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1271
Grade Unit
g/t
Intercept
1.35 m
True Width
0.94 m
From
183.85 m
To
185.2 m
Intercept Depth
183.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-77:183.85-185.2
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1340
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptionally high silver grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.

Positive factors

  • Exceptional silver grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“1,271”

Context: 1.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.94

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-77Terronera Operation · goldGrade: 1.8Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
LL-77
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.8
Grade Unit
g/t
Intercept
0.6 m
True Width
0.42 m
From
183.85 m
To
184.45 m
Intercept Depth
183.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-77:183.85-184.45
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2983
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.

Evidence · table

“1.80”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.42

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-77Terronera Operation · silverGrade: 2830Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
LL-77
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
2830
Grade Unit
g/t
Intercept
0.6 m
True Width
0.42 m
From
183.85 m
To
184.45 m
Intercept Depth
183.85 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-77:183.85-184.45
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2983
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptionally high silver grade, suggesting very high-grade zones within the broader intercept.

Positive factors

  • Exceptional silver grade within a narrower interval.
  • True width reported.
  • Indicates very high-grade pockets within the broader mineralization.

Evidence · table

“2,830”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.42

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-81Terronera Operation · goldGrade: 0.25Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
LL-81
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.25
Grade Unit
g/t
Intercept
1.5 m
True Width
1.32 m
From
145.2 m
To
146.7 m
Intercept Depth
145.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-81:145.2-146.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
153
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.

Positive factors

  • Good true width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.25”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-81Terronera Operation · silverGrade: 131.5Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
LL-81
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
131.5
Grade Unit
g/t
Intercept
1.5 m
True Width
1.32 m
From
145.2 m
To
146.7 m
Intercept Depth
145.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-81:145.2-146.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
153
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“131.5”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-81Terronera Operation · goldGrade: 0.29Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
LL-81
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.29
Grade Unit
g/t
Intercept
0.75 m
True Width
0.66 m
From
145.2 m
To
145.95 m
Intercept Depth
145.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-81:145.2-145.95
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a good true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.29”

Context: 0.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.66

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-81Terronera Operation · silverGrade: 155Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
LL-81
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
155
Grade Unit
g/t
Intercept
0.75 m
True Width
0.66 m
From
145.2 m
To
145.95 m
Intercept Depth
145.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-81:145.2-145.95
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
179
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, improving slightly on the broader intercept.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“155”

Context: 0.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.66

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-82Terronera Operation · goldGrade: 0.52Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LL-82
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.52
Grade Unit
g/t
Intercept
1 m
True Width
0.96 m
From
120.75 m
To
121.75 m
Intercept Depth
120.75 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-82:120.75-121.75
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
129
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade over a good true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.52”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.96

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-82Terronera Operation · silverGrade: 86Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LL-82
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
86
Grade Unit
g/t
Intercept
1 m
True Width
0.96 m
From
120.75 m
To
121.75 m
Intercept Depth
120.75 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-82:120.75-121.75
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
129
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“86”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.96

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-82Terronera Operation · goldGrade: 0.28Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
LL-82
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.28
Grade Unit
g/t
Intercept
0.5 m
True Width
0.48 m
From
120.75 m
To
121.25 m
Intercept Depth
120.75 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-82:120.75-121.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
155
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.28”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

LL-82Terronera Operation · silverGrade: 131Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
LL-82
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
131
Grade Unit
g/t
Intercept
0.5 m
True Width
0.48 m
From
120.75 m
To
121.25 m
Intercept Depth
120.75 m

Classification

Program
exploration
Sample Type
drill
Group ID
LL-82:120.75-121.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
155
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, improving slightly on the broader intercept.

Positive factors

  • Moderate silver grade.
  • True width reported.

Evidence · table

“131”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.48

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-001Terronera Operation · goldGrade: 1.8Grade Unit: g/tIntercept: 10.15 mView all details
Link to this fact

Identity

Hole ID
TRU-001
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.8
Grade Unit
g/t
Intercept
10.15 m
True Width
8.11 m
From
121.4 m
To
131.55 m
Intercept Depth
121.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-001:121.4-131.55
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
435
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a significant true width, indicating robust mineralization and contributing positively to the project's potential.

Positive factors

  • Moderate gold grade over a significant true width.
  • Part of a program extending mineralization.

Evidence · table

“1.80”

Context: 10.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8.11

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-001Terronera Operation · silverGrade: 282Grade Unit: g/tIntercept: 10.15 mView all details
Link to this fact

Identity

Hole ID
TRU-001
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
282
Grade Unit
g/t
Intercept
10.15 m
True Width
8.11 m
From
121.4 m
To
131.55 m
Intercept Depth
121.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-001:121.4-131.55
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
435
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a significant true width, indicating robust mineralization and contributing positively to the project's potential.

Positive factors

  • Strong silver grade over a significant true width.
  • Part of a program extending mineralization.

Evidence · table

“282”

Context: 10.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 8.11

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-001Terronera Operation · goldGrade: 0.49Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
TRU-001
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.49
Grade Unit
g/t
Intercept
1.3 m
True Width
1.04 m
From
122.2 m
To
123.5 m
Intercept Depth
122.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-001:122.2-123.5
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1332
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade over a good true width, which is not particularly material.

Positive factors

  • True width reported.

Negative factors

  • Weak gold grade.

Evidence · table

“0.49”

Context: 1.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-001Terronera Operation · silverGrade: 1290Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
TRU-001
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1290
Grade Unit
g/t
Intercept
1.3 m
True Width
1.04 m
From
122.2 m
To
123.5 m
Intercept Depth
122.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-001:122.2-123.5
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1332
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptionally high silver grade, suggesting very high-grade zones within the broader intercept.

Positive factors

  • Exceptional silver grade within a high-grade zone.
  • True width reported.
  • Confirms very high-grade core within the broader intercept.

Evidence · table

“1290”

Context: 1.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-002Terronera Operation · goldGrade: 2.07Grade Unit: g/tIntercept: 6.7 mView all details
Link to this fact

Identity

Hole ID
TRU-002
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
2.07
Grade Unit
g/t
Intercept
6.7 m
True Width
5.09 m
From
125.8 m
To
132.5 m
Intercept Depth
125.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-002:125.8-132.5
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good true width, contributing positively to the overall understanding of the mineralization.

Positive factors

  • Moderate gold grade over a good true width.
  • Part of a program extending mineralization.

Evidence · table

“2.07”

Context: 6.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.09

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-002Terronera Operation · silverGrade: 80Grade Unit: g/tIntercept: 6.7 mView all details
Link to this fact

Identity

Hole ID
TRU-002
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
80
Grade Unit
g/t
Intercept
6.7 m
True Width
5.09 m
From
125.8 m
To
132.5 m
Intercept Depth
125.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-002:125.8-132.5
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“80”

Context: 6.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.09

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-002Terronera Operation · goldGrade: 3.24Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
TRU-002
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.24
Grade Unit
g/t
Intercept
0.6 m
True Width
0.46 m
From
131.9 m
To
132.5 m
Intercept Depth
131.9 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-002:131.9-132.5
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
472
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Moderate gold grade.
  • True width reported.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“3.24”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.46

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-002Terronera Operation · silverGrade: 197Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
TRU-002
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
197
Grade Unit
g/t
Intercept
0.6 m
True Width
0.46 m
From
131.9 m
To
132.5 m
Intercept Depth
131.9 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-002:131.9-132.5
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
472
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, confirming a higher-grade zone within the broader intercept.

Positive factors

  • Moderate silver grade.
  • True width reported.
  • Confirms high-grade core within the broader intercept.

Evidence · table

“197”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.46

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-003Terronera Operation · goldGrade: 6.3Grade Unit: g/tIntercept: 9.4 mView all details
Link to this fact

Identity

Hole ID
TRU-003
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
6.3
Grade Unit
g/t
Intercept
9.4 m
True Width
5.32 m
From
109.2 m
To
118.6 m
Intercept Depth
109.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-003:109.2-118.6
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows an exceptional gold grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.

Positive factors

  • Exceptional gold grade for an underground mining method.
  • Good true width reported.
  • Part of a program extending mineralization.

Evidence · table

“6.30”

Context: 9.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-003Terronera Operation · silverGrade: 150Grade Unit: g/tIntercept: 9.4 mView all details
Link to this fact

Identity

Hole ID
TRU-003
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
150
Grade Unit
g/t
Intercept
9.4 m
True Width
5.32 m
From
109.2 m
To
118.6 m
Intercept Depth
109.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-003:109.2-118.6
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
686
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.

Positive factors

  • Moderate silver grade.
  • Good true width reported.

Evidence · table

“150”

Context: 9.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.32

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-003Terronera Operation · goldGrade: 12.7Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
TRU-003
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
12.7
Grade Unit
g/t
Intercept
0.6 m
True Width
0.34 m
From
110.2 m
To
110.8 m
Intercept Depth
110.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
TRU-003:110.2-110.8
Mining Method
underground

Location

Location
Terronera
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1320
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: This sub-interval highlights an exceptional gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.

Positive factors

  • Exceptional gold grade within a narrower interval.
  • True width reported.
  • Indicates high-grade pockets within the broader mineralization.

Evidence · table

“12.70”

Context: 0.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-003Terronera Operation · silverGrade: 240Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
TRU-003
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
240
Grade Unit
g/t
Intercept
0.6 m
True Width
0.34 m
From
110.2 m
To
110.8 m
Intercept Depth
110.2 m

Classification

Sample Type
drill
Group ID
TRU-003:110.2-110.8
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1320
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 240 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 144.0 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 240 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“240”

Context: TRU-003

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.34

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-004Terronera Operation · goldGrade: 4.05Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
TRU-004
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
4.05
Grade Unit
g/t
Intercept
6 m
True Width
4.42 m
From
86.4 m
To
92.4 m
Intercept Depth
86.4 m

Classification

Sample Type
drill
Group ID
TRU-004:86.4-92.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
463
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 4.05 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 24.3 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.05”

Context: TRU-004

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.42

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-004Terronera Operation · silverGrade: 119Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
TRU-004
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
119
Grade Unit
g/t
Intercept
6 m
True Width
4.42 m
From
86.4 m
To
92.4 m
Intercept Depth
86.4 m

Classification

Sample Type
drill
Group ID
TRU-004:86.4-92.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
463
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 119 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 714.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“119”

Context: TRU-004

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.42

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-004Terronera Operation · goldGrade: 9.29Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
TRU-004
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
9.29
Grade Unit
g/t
Intercept
1.1 m
True Width
0.81 m
From
88.8 m
To
89.9 m
Intercept Depth
88.8 m

Classification

Sample Type
drill
Group ID
TRU-004:88.8-89.9
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
994
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 9.29 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.2 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 9.29 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.29”

Context: TRU-004

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.81

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-004Terronera Operation · silverGrade: 204Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
TRU-004
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
204
Grade Unit
g/t
Intercept
1.1 m
True Width
0.81 m
From
88.8 m
To
89.9 m
Intercept Depth
88.8 m

Classification

Sample Type
drill
Group ID
TRU-004:88.8-89.9
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
994
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 204 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 224.4 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 204 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“204”

Context: TRU-004

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.81

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-005Terronera Operation · goldGrade: 1.93Grade Unit: g/tIntercept: 9.25 mView all details
Link to this fact

Identity

Hole ID
TRU-005
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.93
Grade Unit
g/t
Intercept
9.25 m
True Width
4.2 m
From
150.25 m
To
159.5 m
Intercept Depth
150.25 m

Classification

Sample Type
drill
Group ID
TRU-005:150.25-159.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
380
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 1.93 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 17.9 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.93”

Context: TRU-005

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-005Terronera Operation · silverGrade: 216Grade Unit: g/tIntercept: 9.25 mView all details
Link to this fact

Identity

Hole ID
TRU-005
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
216
Grade Unit
g/t
Intercept
9.25 m
True Width
4.2 m
From
150.25 m
To
159.5 m
Intercept Depth
150.25 m

Classification

Sample Type
drill
Group ID
TRU-005:150.25-159.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
380
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 216 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 1998.0 g/t·m is moderate (grade alone is strong; the better of the two is used).

Positive factors

  • 216 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“216”

Context: TRU-005

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-005Terronera Operation · goldGrade: 1.19Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
TRU-005
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.19
Grade Unit
g/t
Intercept
0.6 m
True Width
0.27 m
From
151.45 m
To
152.05 m
Intercept Depth
151.45 m

Classification

Sample Type
drill
Group ID
TRU-005:151.45-152.05
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1025
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 1.19 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 1.19 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.19”

Context: TRU-005

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-005Terronera Operation · silverGrade: 924Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
TRU-005
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
924
Grade Unit
g/t
Intercept
0.6 m
True Width
0.27 m
From
151.45 m
To
152.05 m
Intercept Depth
151.45 m

Classification

Sample Type
drill
Group ID
TRU-005:151.45-152.05
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1025
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 924 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 554.4 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 924 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“924”

Context: TRU-005

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-006Terronera Operation · goldGrade: 3.1Grade Unit: g/tIntercept: 6.6 mView all details
Link to this fact

Identity

Hole ID
TRU-006
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.1
Grade Unit
g/t
Intercept
6.6 m
True Width
2.2 m
From
201.7 m
To
208.3 m
Intercept Depth
201.7 m

Classification

Sample Type
drill
Group ID
TRU-006:201.7-208.3
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
393
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 3.1 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 20.5 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.10”

Context: TRU-006

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-006Terronera Operation · silverGrade: 130Grade Unit: g/tIntercept: 6.6 mView all details
Link to this fact

Identity

Hole ID
TRU-006
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
130
Grade Unit
g/t
Intercept
6.6 m
True Width
2.2 m
From
201.7 m
To
208.3 m
Intercept Depth
201.7 m

Classification

Sample Type
drill
Group ID
TRU-006:201.7-208.3
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
393
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 130 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 858.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“130”

Context: TRU-006

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-006Terronera Operation · goldGrade: 14.7Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
TRU-006
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
14.7
Grade Unit
g/t
Intercept
0.8 m
True Width
0.27 m
From
204.6 m
To
205.4 m
Intercept Depth
204.6 m

Classification

Sample Type
drill
Group ID
TRU-006:204.6-205.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1490
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 14.7 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 11.8 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 14.7 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.70”

Context: TRU-006

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-006Terronera Operation · silverGrade: 240Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
TRU-006
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
240
Grade Unit
g/t
Intercept
0.8 m
True Width
0.27 m
From
204.6 m
To
205.4 m
Intercept Depth
204.6 m

Classification

Sample Type
drill
Group ID
TRU-006:204.6-205.4
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1490
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 240 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 192.0 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 240 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“240”

Context: TRU-006

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.27

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-007Terronera Operation · goldGrade: 1.33Grade Unit: g/tIntercept: 4.85 mView all details
Link to this fact

Identity

Hole ID
TRU-007
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
1.33
Grade Unit
g/t
Intercept
4.85 m
True Width
1.82 m
From
182.45 m
To
187.3 m
Intercept Depth
182.45 m

Classification

Sample Type
drill
Group ID
TRU-007:182.45-187.3
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
211
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 1.33 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 6.5 g/t·m is below.

Negative factors

  • 1.33 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.33”

Context: TRU-007

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.82

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-007Terronera Operation · silverGrade: 99Grade Unit: g/tIntercept: 4.85 mView all details
Link to this fact

Identity

Hole ID
TRU-007
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
99
Grade Unit
g/t
Intercept
4.85 m
True Width
1.82 m
From
182.45 m
To
187.3 m
Intercept Depth
182.45 m

Classification

Sample Type
drill
Group ID
TRU-007:182.45-187.3
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
211
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 99 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 480.1 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“99”

Context: TRU-007

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.82

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-007Terronera Operation · goldGrade: 5.02Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
TRU-007
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
5.02
Grade Unit
g/t
Intercept
0.3 m
True Width
0.11 m
From
182.45 m
To
182.75 m
Intercept Depth
182.45 m

Classification

Sample Type
drill
Group ID
TRU-007:182.45-182.75
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
538
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 5.02 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.5 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.02”

Context: TRU-007

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.11

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-007Terronera Operation · silverGrade: 111Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
TRU-007
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
111
Grade Unit
g/t
Intercept
0.3 m
True Width
0.11 m
From
182.45 m
To
182.75 m
Intercept Depth
182.45 m

Classification

Sample Type
drill
Group ID
TRU-007:182.45-182.75
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
538
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 111 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 33.3 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“111”

Context: TRU-007

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.11

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-008Terronera Operation · goldGrade: 5.5Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
TRU-008
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
5 m
True Width
2.07 m
From
156.5 m
To
161.5 m
Intercept Depth
156.5 m

Classification

Sample Type
drill
Group ID
TRU-008:156.5-161.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
624
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 5.5 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 27.5 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.50”

Context: TRU-008

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.07

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-008Terronera Operation · silverGrade: 156Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
TRU-008
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
156
Grade Unit
g/t
Intercept
5 m
True Width
2.07 m
From
156.5 m
To
161.5 m
Intercept Depth
156.5 m

Classification

Sample Type
drill
Group ID
TRU-008:156.5-161.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
624
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 156 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 780.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“156”

Context: TRU-008

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.07

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-008Terronera Operation · goldGrade: 14.6Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
TRU-008
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
14.6
Grade Unit
g/t
Intercept
0.75 m
True Width
0.31 m
From
159.5 m
To
160.25 m
Intercept Depth
159.5 m

Classification

Sample Type
drill
Group ID
TRU-008:159.5-160.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1594
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 14.6 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.9 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 14.6 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.60”

Context: TRU-008

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-008Terronera Operation · silverGrade: 353Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
TRU-008
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
353
Grade Unit
g/t
Intercept
0.75 m
True Width
0.31 m
From
159.5 m
To
160.25 m
Intercept Depth
159.5 m

Classification

Sample Type
drill
Group ID
TRU-008:159.5-160.25
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1594
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 353 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 264.8 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 353 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“353”

Context: TRU-008

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-009Terronera Operation · goldGrade: 3.41Grade Unit: g/tIntercept: 8.8 mView all details
Link to this fact

Identity

Hole ID
TRU-009
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
3.41
Grade Unit
g/t
Intercept
8.8 m
True Width
4.2 m
From
147.1 m
To
155.9 m
Intercept Depth
147.1 m

Classification

Sample Type
drill
Group ID
TRU-009:147.1-155.9
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
379
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 3.41 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 30.0 g/t·m is moderate (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.41”

Context: TRU-009

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-009Terronera Operation · silverGrade: 89Grade Unit: g/tIntercept: 8.8 mView all details
Link to this fact

Identity

Hole ID
TRU-009
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
89
Grade Unit
g/t
Intercept
8.8 m
True Width
4.2 m
From
147.1 m
To
155.9 m
Intercept Depth
147.1 m

Classification

Sample Type
drill
Group ID
TRU-009:147.1-155.9
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
379
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 89 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 783.2 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“89”

Context: TRU-009

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-009Terronera Operation · goldGrade: 13.5Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
TRU-009
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
13.5
Grade Unit
g/t
Intercept
0.8 m
True Width
0.38 m
From
147.9 m
To
148.7 m
Intercept Depth
147.9 m

Classification

Sample Type
drill
Group ID
TRU-009:147.9-148.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1468
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 13.5 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.8 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 13.5 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.50”

Context: TRU-009

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.38

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-009Terronera Operation · silverGrade: 320Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
TRU-009
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
320
Grade Unit
g/t
Intercept
0.8 m
True Width
0.38 m
From
147.9 m
To
148.7 m
Intercept Depth
147.9 m

Classification

Sample Type
drill
Group ID
TRU-009:147.9-148.7
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1468
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 320 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 256.0 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 320 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“320”

Context: TRU-009

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.38

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-010Terronera Operation · goldGrade: 0.09Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
TRU-010
Project
Terronera Operation
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
0.09
Grade Unit
g/t
Intercept
3.3 m
True Width
0.99 m
From
208.2 m
To
211.5 m
Intercept Depth
208.2 m

Classification

Sample Type
drill
Group ID
TRU-010:208.2-211.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
21
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.09 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: TRU-010

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.99

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

TRU-010Terronera Operation · silverGrade: 14Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
TRU-010
Project
Terronera Operation
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
EDR

Geometry

Grade
14
Grade Unit
g/t
Intercept
3.3 m
True Width
0.99 m
From
208.2 m
To
211.5 m
Intercept Depth
208.2 m

Classification

Sample Type
drill
Group ID
TRU-010:208.2-211.5
Mining Method
underground

Location

Location
La Luz
Loc. Source
document

QA/QC

Laboratory
ALS and SGS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
21
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-18T00:00:00.000Z

Reasoning: Expanded from assay table. 14 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 46.2 g/t·m is below.

Negative factors

  • 14 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14”

Context: TRU-010

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.99

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.