Endeavour Silver Intersects High-Grade Silver and Gold Mineralization at its Terronera Operation
Original announcement by tmx on
- Company
- Endeavour Silver Corp.
- Ticker
- EDR
- Exchange
- TSX
- Region
- Jalisco, Mexico
- Primary commodity
- Silver
- Secondary commodities
- Gold
- Document categories
- Drill results
- Extracted
- 2026-09-19 18:50:39 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Endeavour Silver announced high-grade silver and gold drill results from its Terronera operation in Jalisco, Mexico, extending mineralization at the La Luz and Terronera veins along strike and at depth. Key intercepts include 2,607 g/t AgEq over 1.06 meters true width in hole LL-43 and 686 g/t AgEq over 5.32 meters true width in hole TRU-003. The exploration program aims to support mine design, resource growth, and extend the mine life.
Reasoning: The drill results show high-grade silver and gold mineralization with good true widths, extending known veins at depth and along strike. The program is designed to support mine design and resource growth, indicating positive progress for the Terronera operation. QA/QC is well-disclosed.
Positive factors
- High-grade silver and gold intercepts, particularly in LL-43 and LL-77, demonstrate strong mineralization.
- Significant true widths reported for several intercepts, adding confidence to the continuity.
- Drilling successfully extended mineralization along strike and at depth in both La Luz and Terronera veins.
- QA/QC procedures are clearly disclosed, including certified labs and QP sign-off.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 118
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Hole LL-43 returned 23.92 g/t Au and 574 g/t Ag over 1.06 m true width, with an AgEq of 2,607 g/t, which is exceptionally high-grade for silver and gold.
Evidence · text
“LL-43: 574 g/t Ag, 23.92 g/t Au for 2,607 g/t AgEq over 1.06 metres true width”
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Hole LL-77 returned 0.81 g/t Au and 1,271 g/t Ag over 0.94 m true width, with an AgEq of 1,340 g/t, which is exceptionally high-grade for silver.
Evidence · text
“LL-77: 1,271 g/t Ag, 0.81 g/t Au for 1,340 g/t AgEq over 0.94 metres true width”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The drill results tables explicitly provide 'True Width (m)' for all reported intercepts.
Evidence · table
“1.06”
Context: 1.30
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The news release details the QA/QC program, including certified laboratories (ALS and SGS) and the use of standards, blanks, and duplicates.
Evidence · text
“A quality control sampling program of reference standards, blanks and duplicates has been instituted to monitor the integrity of all assay results.”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The program is designed to 'expand and better define mineralization along strike and at depth' and has 'successfully extended mineralization along strike and at depth'.
Evidence · text
“The program is designed to expand and better define mineralization along strike and at depth within the Terronera vein system.”
QP/CP Signedpositive · Story-specific tag
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: Dale Mah, P.Geo., a qualified person under NI 43-101, has approved the scientific and technical information.
Evidence · text
“Dale Mah, P.Geo., Vice President Corporate Development, a qualified person under NI 43-101, has approved the scientific and technical information contained in this news release.”
Extracted facts
Stored fact records: 118. Some facts used in scoring do not have a stored record.
Drill Results (118)
LL-43Terronera Operation · goldGrade: 23.92Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- LL-43
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 23.92
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.06 m
- From
- 104.1 m
- To
- 105.4 m
- Intercept Depth
- 104.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-43:104.1-105.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2607
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptionally high gold grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.
Positive factors
- Exceptional gold grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“23.92”
Context: 1.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.06
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-43Terronera Operation · silverGrade: 574Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- LL-43
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 574
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.06 m
- From
- 104.1 m
- To
- 105.4 m
- Intercept Depth
- 104.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-43:104.1-105.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2607
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptionally high silver grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.
Positive factors
- Exceptional silver grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“574”
Context: 1.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.06
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-43Terronera Operation · goldGrade: 44.4Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- LL-43
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 44.4
- Grade Unit
- g/t
- Intercept
- 0.7 m
- True Width
- 0.57 m
- From
- 104.7 m
- To
- 105.4 m
- Intercept Depth
- 104.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-43:104.7-105.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4834
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows an even higher gold grade, reinforcing the bonanza nature of the LL-43 intercept.
Positive factors
- Exceptional gold grade within a high-grade zone.
- True width reported.
- Confirms very high-grade core within the broader intercept.
Evidence · table
“44.40”
Context: 0.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-43Terronera Operation · silverGrade: 1060Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- LL-43
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1060
- Grade Unit
- g/t
- Intercept
- 0.7 m
- True Width
- 0.57 m
- From
- 104.7 m
- To
- 105.4 m
- Intercept Depth
- 104.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-43:104.7-105.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4834
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows an even higher silver grade, reinforcing the bonanza nature of the LL-43 intercept.
Positive factors
- Exceptional silver grade within a high-grade zone.
- True width reported.
- Confirms very high-grade core within the broader intercept.
Evidence · table
“1,060”
Context: 0.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-44Terronera Operation · goldGrade: 3.84Grade Unit: g/tIntercept: 2.95 mView all detailsHide details
Identity
- Hole ID
- LL-44
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.84
- Grade Unit
- g/t
- Intercept
- 2.95 m
- True Width
- 2.26 m
- From
- 120.1 m
- To
- 123.05 m
- Intercept Depth
- 120.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-44:120.1-123.05
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 503
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade over a good true width.
- Part of a program extending mineralization.
Evidence · table
“3.84”
Context: 2.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.26
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-44Terronera Operation · silverGrade: 176Grade Unit: g/tIntercept: 2.95 mView all detailsHide details
Identity
- Hole ID
- LL-44
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 176
- Grade Unit
- g/t
- Intercept
- 2.95 m
- True Width
- 2.26 m
- From
- 120.1 m
- To
- 123.05 m
- Intercept Depth
- 120.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-44:120.1-123.05
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 503
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade over a good true width.
- Part of a program extending mineralization.
Evidence · table
“176”
Context: 2.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.26
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-44Terronera Operation · goldGrade: 18.15Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- LL-44
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 18.15
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.34 m
- From
- 122.6 m
- To
- 123.05 m
- Intercept Depth
- 122.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-44:122.6-123.05
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2360
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights a strong gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.
Positive factors
- Strong gold grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“18.15”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.34
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-44Terronera Operation · silverGrade: 817Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- LL-44
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 817
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.34 m
- From
- 122.6 m
- To
- 123.05 m
- Intercept Depth
- 122.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-44:122.6-123.05
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2360
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional silver grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.
Positive factors
- Exceptional silver grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“817”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.34
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-48Terronera Operation · goldGrade: 1.08Grade Unit: g/tIntercept: 1.55 mView all detailsHide details
Identity
- Hole ID
- LL-48
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.08
- Grade Unit
- g/t
- Intercept
- 1.55 m
- True Width
- 0.95 m
- From
- 124.85 m
- To
- 126.4 m
- Intercept Depth
- 124.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-48:124.85-126.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 100
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a narrow true width, contributing to the overall understanding of the mineralization but not a highlight.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“1.08”
Context: 1.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-48Terronera Operation · silverGrade: 8Grade Unit: g/tIntercept: 1.55 mView all detailsHide details
Identity
- Hole ID
- LL-48
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 8
- Grade Unit
- g/t
- Intercept
- 1.55 m
- True Width
- 0.95 m
- From
- 124.85 m
- To
- 126.4 m
- Intercept Depth
- 124.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-48:124.85-126.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 100
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade, which is not particularly material, though true width is reported.
Positive factors
- True width reported.
Negative factors
- Weak silver grade.
Evidence · table
“8”
Context: 1.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-48Terronera Operation · goldGrade: 1.93Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- LL-48
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.93
- Grade Unit
- g/t
- Intercept
- 0.85 m
- True Width
- 0.52 m
- From
- 125.55 m
- To
- 126.4 m
- Intercept Depth
- 125.55 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-48:125.55-126.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 173
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“1.93”
Context: 0.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.52
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-48Terronera Operation · silverGrade: 10Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- LL-48
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 10
- Grade Unit
- g/t
- Intercept
- 0.85 m
- True Width
- 0.52 m
- From
- 125.55 m
- To
- 126.4 m
- Intercept Depth
- 125.55 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-48:125.55-126.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 173
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak silver grade, which is not particularly material, though true width is reported.
Positive factors
- True width reported.
Negative factors
- Weak silver grade.
Evidence · table
“10”
Context: 0.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.52
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-49Terronera Operation · goldGrade: 3.43Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- LL-49
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.43
- Grade Unit
- g/t
- Intercept
- 1.35 m
- True Width
- 1.3 m
- From
- 77 m
- To
- 78.35 m
- Intercept Depth
- 77 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-49:77-78.35
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 871
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade over a good true width.
- Part of a program extending mineralization.
Evidence · table
“3.43”
Context: 1.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-49Terronera Operation · silverGrade: 579Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- LL-49
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 579
- Grade Unit
- g/t
- Intercept
- 1.35 m
- True Width
- 1.3 m
- From
- 77 m
- To
- 78.35 m
- Intercept Depth
- 77 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-49:77-78.35
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 871
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptional silver grade over a good true width, indicating strong mineralization.
Positive factors
- Exceptional silver grade over a good true width.
- Part of a program extending mineralization.
Evidence · table
“579”
Context: 1.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-49Terronera Operation · goldGrade: 4.47Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LL-49
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 4.47
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.93 m
- From
- 77 m
- To
- 78 m
- Intercept Depth
- 77 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-49:77-78
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1121
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a good true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Moderate gold grade over a good true width.
- Confirms high-grade core within the broader intercept.
Evidence · table
“4.47”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.93
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-49Terronera Operation · silverGrade: 741Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LL-49
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 741
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.93 m
- From
- 77 m
- To
- 78 m
- Intercept Depth
- 77 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-49:77-78
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1121
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional silver grade over a good true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Exceptional silver grade over a good true width.
- Confirms high-grade core within the broader intercept.
Evidence · table
“741”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.93
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-50Terronera Operation · goldGrade: 0.47Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- LL-50
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.47
- Grade Unit
- g/t
- Intercept
- 1.25 m
- True Width
- 1.2 m
- From
- 78 m
- To
- 79.25 m
- Intercept Depth
- 78 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-50:78-79.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 120
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade, which is not particularly material, though true width is reported.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.47”
Context: 1.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-50Terronera Operation · silverGrade: 80Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- LL-50
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 80
- Grade Unit
- g/t
- Intercept
- 1.25 m
- True Width
- 1.2 m
- From
- 78 m
- To
- 79.25 m
- Intercept Depth
- 78 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-50:78-79.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 120
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- True width reported.
Evidence · table
“80”
Context: 1.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-50Terronera Operation · goldGrade: 0.86Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LL-50
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.57 m
- From
- 78 m
- To
- 78.6 m
- Intercept Depth
- 78 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-50:78-78.6
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 196
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“0.86”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-50Terronera Operation · silverGrade: 123Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LL-50
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 123
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.57 m
- From
- 78 m
- To
- 78.6 m
- Intercept Depth
- 78 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-50:78-78.6
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 196
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, improving slightly on the broader intercept.
Positive factors
- Moderate silver grade.
- True width reported.
Evidence · table
“123”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-51Terronera Operation · goldGrade: 1.99Grade Unit: g/tIntercept: 2.15 mView all detailsHide details
Identity
- Hole ID
- LL-51
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.99
- Grade Unit
- g/t
- Intercept
- 2.15 m
- True Width
- 0.94 m
- From
- 139.1 m
- To
- 141.25 m
- Intercept Depth
- 139.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-51:139.1-141.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 196
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a narrow true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“1.99”
Context: 2.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.94
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-51Terronera Operation · silverGrade: 27Grade Unit: g/tIntercept: 2.15 mView all detailsHide details
Identity
- Hole ID
- LL-51
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 27
- Grade Unit
- g/t
- Intercept
- 2.15 m
- True Width
- 0.94 m
- From
- 139.1 m
- To
- 141.25 m
- Intercept Depth
- 139.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-51:139.1-141.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 196
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade, which is not particularly material, though true width is reported.
Positive factors
- True width reported.
Negative factors
- Weak silver grade.
Evidence · table
“27”
Context: 2.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.94
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-51Terronera Operation · goldGrade: 3.75Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LL-51
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.75
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.28 m
- From
- 140.6 m
- To
- 141.25 m
- Intercept Depth
- 140.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-51:140.6-141.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 360
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, suggesting high-grade zones within the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“3.75”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.28
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-51Terronera Operation · silverGrade: 41Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LL-51
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 41
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.28 m
- From
- 140.6 m
- To
- 141.25 m
- Intercept Depth
- 140.6 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-51:140.6-141.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 360
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak silver grade over a narrow true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak silver grade.
Evidence · table
“41”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.28
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-52Terronera Operation · goldGrade: 15.86Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- LL-52
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 15.86
- Grade Unit
- g/t
- Intercept
- 2.2 m
- True Width
- 1.13 m
- From
- 151.35 m
- To
- 153.55 m
- Intercept Depth
- 151.35 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-52:151.35-153.55
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1404
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptional gold grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.
Positive factors
- Exceptional gold grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“15.86”
Context: 2.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.13
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-52Terronera Operation · silverGrade: 55Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- LL-52
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 55
- Grade Unit
- g/t
- Intercept
- 2.2 m
- True Width
- 1.13 m
- From
- 151.35 m
- To
- 153.55 m
- Intercept Depth
- 151.35 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-52:151.35-153.55
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1404
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- True width reported.
Evidence · table
“55”
Context: 2.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.13
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-52Terronera Operation · goldGrade: 18.4Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- LL-52
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 18.4
- Grade Unit
- g/t
- Intercept
- 0.9 m
- True Width
- 0.46 m
- From
- 152.65 m
- To
- 153.55 m
- Intercept Depth
- 152.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-52:152.65-153.55
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1640
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.
Positive factors
- Exceptional gold grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“18.40”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.46
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-52Terronera Operation · silverGrade: 76Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- LL-52
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 76
- Grade Unit
- g/t
- Intercept
- 0.9 m
- True Width
- 0.46 m
- From
- 152.65 m
- To
- 153.55 m
- Intercept Depth
- 152.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-52:152.65-153.55
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1640
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- True width reported.
Evidence · table
“76”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.46
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-55Terronera Operation · goldGrade: 1.66Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- LL-55
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.66
- Grade Unit
- g/t
- Intercept
- 1.6 m
- True Width
- 1.31 m
- From
- 84.5 m
- To
- 86.1 m
- Intercept Depth
- 84.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-55:84.5-86.1
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 160
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade.
- Good true width reported.
Evidence · table
“1.66”
Context: 1.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.31
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-55Terronera Operation · silverGrade: 19Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- LL-55
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 19
- Grade Unit
- g/t
- Intercept
- 1.6 m
- True Width
- 1.31 m
- From
- 84.5 m
- To
- 86.1 m
- Intercept Depth
- 84.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-55:84.5-86.1
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 160
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak silver grade, which is not particularly material, though good true width is reported.
Positive factors
- Good true width reported.
Negative factors
- Weak silver grade.
Evidence · table
“19”
Context: 1.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.31
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-55Terronera Operation · goldGrade: 2.77Grade Unit: g/tIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LL-55
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 2.77
- Grade Unit
- g/t
- Intercept
- 0.95 m
- True Width
- 0.78 m
- From
- 85.15 m
- To
- 86.1 m
- Intercept Depth
- 85.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-55:85.15-86.1
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 266
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a good true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Moderate gold grade over a good true width.
- Confirms high-grade core within the broader intercept.
Evidence · table
“2.77”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-55Terronera Operation · silverGrade: 30Grade Unit: g/tIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LL-55
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 30
- Grade Unit
- g/t
- Intercept
- 0.95 m
- True Width
- 0.78 m
- From
- 85.15 m
- To
- 86.1 m
- Intercept Depth
- 85.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-55:85.15-86.1
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 266
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a good true width, improving slightly on the broader intercept.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“30”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-59Terronera Operation · goldGrade: 7.47Grade Unit: g/tIntercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- LL-59
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 7.47
- Grade Unit
- g/t
- Intercept
- 2.3 m
- True Width
- 2.12 m
- From
- 135.1 m
- To
- 137.4 m
- Intercept Depth
- 135.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-59:135.1-137.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1013
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade over a good true width, indicating significant mineralization and contributing positively to the project's potential.
Positive factors
- Strong gold grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“7.47”
Context: 2.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.12
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-59Terronera Operation · silverGrade: 378Grade Unit: g/tIntercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- LL-59
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 378
- Grade Unit
- g/t
- Intercept
- 2.3 m
- True Width
- 2.12 m
- From
- 135.1 m
- To
- 137.4 m
- Intercept Depth
- 135.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-59:135.1-137.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1013
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade over a good true width, indicating significant mineralization and contributing positively to the project's potential.
Positive factors
- Strong silver grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“378”
Context: 2.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.12
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-59Terronera Operation · goldGrade: 17.9Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- LL-59
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 17.9
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.69 m
- From
- 135.1 m
- To
- 135.85 m
- Intercept Depth
- 135.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-59:135.1-135.85
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1962
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.
Positive factors
- Exceptional gold grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“17.90”
Context: 0.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.69
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-59Terronera Operation · silverGrade: 440Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- LL-59
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 440
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.69 m
- From
- 135.1 m
- To
- 135.85 m
- Intercept Depth
- 135.1 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-59:135.1-135.85
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1962
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional silver grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.
Positive factors
- Exceptional silver grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“440”
Context: 0.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.69
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-61Terronera Operation · goldGrade: 0.65Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- LL-61
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.65
- Grade Unit
- g/t
- Intercept
- 2.2 m
- True Width
- 2.07 m
- From
- 138 m
- To
- 140.2 m
- Intercept Depth
- 138 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-61:138-140.2
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 148
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.65”
Context: 2.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-61Terronera Operation · silverGrade: 93Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- LL-61
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 93
- Grade Unit
- g/t
- Intercept
- 2.2 m
- True Width
- 2.07 m
- From
- 138 m
- To
- 140.2 m
- Intercept Depth
- 138 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-61:138-140.2
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 148
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“93”
Context: 2.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-61Terronera Operation · goldGrade: 0.53Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- LL-61
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.42 m
- From
- 139.75 m
- To
- 140.2 m
- Intercept Depth
- 139.75 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-61:139.75-140.2
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 278
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.53”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-61Terronera Operation · silverGrade: 233Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- LL-61
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 233
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.42 m
- From
- 139.75 m
- To
- 140.2 m
- Intercept Depth
- 139.75 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-61:139.75-140.2
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 278
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade over a narrow true width, indicating a high-grade pocket.
Positive factors
- Strong silver grade.
- True width reported.
Evidence · table
“233”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-63Terronera Operation · goldGrade: 0.65Grade Unit: g/tIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LL-63
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.65
- Grade Unit
- g/t
- Intercept
- 0.95 m
- True Width
- 0.86 m
- From
- 155.65 m
- To
- 156.6 m
- Intercept Depth
- 155.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-63:155.65-156.6
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 481
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade over a good true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.65”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.86
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-63Terronera Operation · silverGrade: 426Grade Unit: g/tIntercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LL-63
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 426
- Grade Unit
- g/t
- Intercept
- 0.95 m
- True Width
- 0.86 m
- From
- 155.65 m
- To
- 156.6 m
- Intercept Depth
- 155.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-63:155.65-156.6
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 481
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptional silver grade over a good true width, indicating strong mineralization.
Positive factors
- Exceptional silver grade over a good true width.
- Part of a program extending mineralization.
Evidence · table
“426”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.86
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-63Terronera Operation · goldGrade: 1.68Grade Unit: g/tIntercept: 0.35 mView all detailsHide details
Identity
- Hole ID
- LL-63
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.68
- Grade Unit
- g/t
- Intercept
- 0.35 m
- True Width
- 0.32 m
- From
- 155.65 m
- To
- 156 m
- Intercept Depth
- 155.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-63:155.65-156
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1287
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“1.68”
Context: 0.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.32
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-63Terronera Operation · silverGrade: 1145Grade Unit: g/tIntercept: 0.35 mView all detailsHide details
Identity
- Hole ID
- LL-63
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1145
- Grade Unit
- g/t
- Intercept
- 0.35 m
- True Width
- 0.32 m
- From
- 155.65 m
- To
- 156 m
- Intercept Depth
- 155.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-63:155.65-156
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1287
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional silver grade, suggesting very high-grade zones within the broader intercept.
Positive factors
- Exceptional silver grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“1,145”
Context: 0.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.32
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-67Terronera Operation · goldGrade: 2.01Grade Unit: g/tIntercept: 1.55 mView all detailsHide details
Identity
- Hole ID
- LL-67
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 2.01
- Grade Unit
- g/t
- Intercept
- 1.55 m
- True Width
- 1.37 m
- From
- 146.8 m
- To
- 148.35 m
- Intercept Depth
- 146.8 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-67:146.8-148.35
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 285
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade.
- Good true width reported.
Evidence · table
“2.01”
Context: 1.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.37
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-67Terronera Operation · silverGrade: 115Grade Unit: g/tIntercept: 1.55 mView all detailsHide details
Identity
- Hole ID
- LL-67
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 115
- Grade Unit
- g/t
- Intercept
- 1.55 m
- True Width
- 1.37 m
- From
- 146.8 m
- To
- 148.35 m
- Intercept Depth
- 146.8 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-67:146.8-148.35
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 285
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“115”
Context: 1.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.37
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-67Terronera Operation · goldGrade: 4.62Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LL-67
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 4.62
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.57 m
- From
- 147 m
- To
- 147.65 m
- Intercept Depth
- 147 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-67:147-147.65
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 617
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a strong gold grade over a narrow true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Strong gold grade.
- True width reported.
- Confirms high-grade core within the broader intercept.
Evidence · table
“4.62”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-67Terronera Operation · silverGrade: 224Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LL-67
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 224
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.57 m
- From
- 147 m
- To
- 147.65 m
- Intercept Depth
- 147 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-67:147-147.65
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 617
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade over a narrow true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Strong silver grade.
- True width reported.
- Confirms high-grade core within the broader intercept.
Evidence · table
“224”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-68Terronera Operation · goldGrade: 1.12Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LL-68
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.12
- Grade Unit
- g/t
- Intercept
- 1.5 m
- True Width
- 1.19 m
- From
- 180.5 m
- To
- 182 m
- Intercept Depth
- 180.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-68:180.5-182
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 348
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade.
- Good true width reported.
Evidence · table
“1.12”
Context: 1.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.19
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-68Terronera Operation · silverGrade: 252.8Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LL-68
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 252.8
- Grade Unit
- g/t
- Intercept
- 1.5 m
- True Width
- 1.19 m
- From
- 180.5 m
- To
- 182 m
- Intercept Depth
- 180.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-68:180.5-182
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 348
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Strong silver grade.
- Good true width reported.
Evidence · table
“252.8”
Context: 1.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.19
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-68Terronera Operation · goldGrade: 1.55Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LL-68
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.55
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.79 m
- From
- 180.5 m
- To
- 181.5 m
- Intercept Depth
- 180.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-68:180.5-181.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 461
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a good true width, improving slightly on the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“1.55”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.79
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-68Terronera Operation · silverGrade: 330Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LL-68
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 330
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.79 m
- From
- 180.5 m
- To
- 181.5 m
- Intercept Depth
- 180.5 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-68:180.5-181.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 461
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade over a good true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Strong silver grade.
- True width reported.
- Confirms high-grade core within the broader intercept.
Evidence · table
“330”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.79
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-69Terronera Operation · goldGrade: 0.31Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- LL-69
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 1.6 m
- True Width
- 1.13 m
- From
- 204.9 m
- To
- 206.5 m
- Intercept Depth
- 204.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-69:204.9-206.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 198
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.31”
Context: 1.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.13
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-69Terronera Operation · silverGrade: 172Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- LL-69
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 172
- Grade Unit
- g/t
- Intercept
- 1.6 m
- True Width
- 1.13 m
- From
- 204.9 m
- To
- 206.5 m
- Intercept Depth
- 204.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-69:204.9-206.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 198
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“172”
Context: 1.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.13
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-69Terronera Operation · goldGrade: 0.43Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LL-69
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.57 m
- From
- 205.7 m
- To
- 206.5 m
- Intercept Depth
- 205.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-69:205.7-206.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 280
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.43”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-69Terronera Operation · silverGrade: 243Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LL-69
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 243
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.57 m
- From
- 205.7 m
- To
- 206.5 m
- Intercept Depth
- 205.7 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-69:205.7-206.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 280
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade over a narrow true width, indicating a high-grade pocket.
Positive factors
- Strong silver grade.
- True width reported.
Evidence · table
“243”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.57
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-74Terronera Operation · goldGrade: 2.41Grade Unit: g/tIntercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- LL-74
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 2.41
- Grade Unit
- g/t
- Intercept
- 1.7 m
- True Width
- 1.5 m
- From
- 130 m
- To
- 131.7 m
- Intercept Depth
- 130 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-74:130-131.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 354
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade.
- Good true width reported.
Evidence · table
“2.41”
Context: 1.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-74Terronera Operation · silverGrade: 149.5Grade Unit: g/tIntercept: 1.7 mView all detailsHide details
Identity
- Hole ID
- LL-74
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 149.5
- Grade Unit
- g/t
- Intercept
- 1.7 m
- True Width
- 1.5 m
- From
- 130 m
- To
- 131.7 m
- Intercept Depth
- 130 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-74:130-131.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 354
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“149.5”
Context: 1.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-74Terronera Operation · goldGrade: 3.68Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- LL-74
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.68
- Grade Unit
- g/t
- Intercept
- 0.85 m
- True Width
- 0.75 m
- From
- 130.85 m
- To
- 131.7 m
- Intercept Depth
- 130.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-74:130.85-131.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 417
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a good true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Moderate gold grade over a good true width.
- Confirms high-grade core within the broader intercept.
Evidence · table
“3.68”
Context: 0.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-74Terronera Operation · silverGrade: 104Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- LL-74
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 104
- Grade Unit
- g/t
- Intercept
- 0.85 m
- True Width
- 0.75 m
- From
- 130.85 m
- To
- 131.7 m
- Intercept Depth
- 130.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-74:130.85-131.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 417
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a good true width, improving slightly on the broader intercept.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“104”
Context: 0.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.75
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-75Terronera Operation · goldGrade: 0.36Grade Unit: g/tIntercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- LL-75
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 1.9 m
- True Width
- 1.41 m
- From
- 174.55 m
- To
- 176.45 m
- Intercept Depth
- 174.55 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-75:174.55-176.45
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 262
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.
Positive factors
- Good true width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.36”
Context: 1.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.41
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-75Terronera Operation · silverGrade: 231Grade Unit: g/tIntercept: 1.9 mView all detailsHide details
Identity
- Hole ID
- LL-75
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 231
- Grade Unit
- g/t
- Intercept
- 1.9 m
- True Width
- 1.41 m
- From
- 174.55 m
- To
- 176.45 m
- Intercept Depth
- 174.55 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-75:174.55-176.45
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 262
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Strong silver grade.
- Good true width reported.
Evidence · table
“231”
Context: 1.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.41
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-75Terronera Operation · goldGrade: 0.44Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LL-75
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.44
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.59 m
- From
- 174.8 m
- To
- 175.6 m
- Intercept Depth
- 174.8 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-75:174.8-175.6
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 373
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.44”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.59
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-75Terronera Operation · silverGrade: 336Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- LL-75
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 336
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.59 m
- From
- 174.8 m
- To
- 175.6 m
- Intercept Depth
- 174.8 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-75:174.8-175.6
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 373
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade over a narrow true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Strong silver grade.
- True width reported.
- Confirms high-grade core within the broader intercept.
Evidence · table
“336”
Context: 0.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.59
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-76Terronera Operation · goldGrade: 0.26Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LL-76
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 1.8 m
- True Width
- 1.14 m
- From
- 234 m
- To
- 235.8 m
- Intercept Depth
- 234 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-76:234-235.8
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 218
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.
Positive factors
- Good true width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.26”
Context: 1.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.14
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-76Terronera Operation · silverGrade: 195Grade Unit: g/tIntercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LL-76
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 195
- Grade Unit
- g/t
- Intercept
- 1.8 m
- True Width
- 1.14 m
- From
- 234 m
- To
- 235.8 m
- Intercept Depth
- 234 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-76:234-235.8
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 218
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“195”
Context: 1.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.14
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-76Terronera Operation · goldGrade: 0.68Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LL-76
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.68
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.41 m
- From
- 235.15 m
- To
- 235.8 m
- Intercept Depth
- 235.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-76:235.15-235.8
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 570
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.68”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.41
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-76Terronera Operation · silverGrade: 512Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- LL-76
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 512
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.41 m
- From
- 235.15 m
- To
- 235.8 m
- Intercept Depth
- 235.15 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-76:235.15-235.8
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 570
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional silver grade, suggesting high-grade zones within the broader intercept.
Positive factors
- Exceptional silver grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“512”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.41
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-77Terronera Operation · goldGrade: 0.81Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- LL-77
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
- Intercept
- 1.35 m
- True Width
- 0.94 m
- From
- 183.85 m
- To
- 185.2 m
- Intercept Depth
- 183.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-77:183.85-185.2
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1340
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade over a good true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.81”
Context: 1.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.94
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-77Terronera Operation · silverGrade: 1271Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Hole ID
- LL-77
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1271
- Grade Unit
- g/t
- Intercept
- 1.35 m
- True Width
- 0.94 m
- From
- 183.85 m
- To
- 185.2 m
- Intercept Depth
- 183.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-77:183.85-185.2
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1340
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptionally high silver grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.
Positive factors
- Exceptional silver grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“1,271”
Context: 1.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.94
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-77Terronera Operation · goldGrade: 1.8Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LL-77
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.8
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.42 m
- From
- 183.85 m
- To
- 184.45 m
- Intercept Depth
- 183.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-77:183.85-184.45
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2983
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, improving slightly on the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
Evidence · table
“1.80”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-77Terronera Operation · silverGrade: 2830Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- LL-77
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 2830
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.42 m
- From
- 183.85 m
- To
- 184.45 m
- Intercept Depth
- 183.85 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-77:183.85-184.45
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2983
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptionally high silver grade, suggesting very high-grade zones within the broader intercept.
Positive factors
- Exceptional silver grade within a narrower interval.
- True width reported.
- Indicates very high-grade pockets within the broader mineralization.
Evidence · table
“2,830”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-81Terronera Operation · goldGrade: 0.25Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LL-81
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 1.5 m
- True Width
- 1.32 m
- From
- 145.2 m
- To
- 146.7 m
- Intercept Depth
- 145.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-81:145.2-146.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 153
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade, which is not particularly material, though good true width is reported.
Positive factors
- Good true width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.25”
Context: 1.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.32
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-81Terronera Operation · silverGrade: 131.5Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- LL-81
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 131.5
- Grade Unit
- g/t
- Intercept
- 1.5 m
- True Width
- 1.32 m
- From
- 145.2 m
- To
- 146.7 m
- Intercept Depth
- 145.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-81:145.2-146.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 153
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“131.5”
Context: 1.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.32
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-81Terronera Operation · goldGrade: 0.29Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- LL-81
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.66 m
- From
- 145.2 m
- To
- 145.95 m
- Intercept Depth
- 145.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-81:145.2-145.95
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 179
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a good true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.29”
Context: 0.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.66
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-81Terronera Operation · silverGrade: 155Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- LL-81
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 155
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.66 m
- From
- 145.2 m
- To
- 145.95 m
- Intercept Depth
- 145.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-81:145.2-145.95
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 179
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a good true width, improving slightly on the broader intercept.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“155”
Context: 0.75
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.66
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-82Terronera Operation · goldGrade: 0.52Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LL-82
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.52
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.96 m
- From
- 120.75 m
- To
- 121.75 m
- Intercept Depth
- 120.75 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-82:120.75-121.75
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 129
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade over a good true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.52”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.96
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-82Terronera Operation · silverGrade: 86Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- LL-82
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 86
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.96 m
- From
- 120.75 m
- To
- 121.75 m
- Intercept Depth
- 120.75 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-82:120.75-121.75
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 129
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“86”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.96
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-82Terronera Operation · goldGrade: 0.28Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LL-82
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.48 m
- From
- 120.75 m
- To
- 121.25 m
- Intercept Depth
- 120.75 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-82:120.75-121.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 155
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a narrow true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.28”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.48
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
LL-82Terronera Operation · silverGrade: 131Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- LL-82
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 131
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.48 m
- From
- 120.75 m
- To
- 121.25 m
- Intercept Depth
- 120.75 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- LL-82:120.75-121.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 155
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, improving slightly on the broader intercept.
Positive factors
- Moderate silver grade.
- True width reported.
Evidence · table
“131”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.48
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-001Terronera Operation · goldGrade: 1.8Grade Unit: g/tIntercept: 10.15 mView all detailsHide details
Identity
- Hole ID
- TRU-001
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.8
- Grade Unit
- g/t
- Intercept
- 10.15 m
- True Width
- 8.11 m
- From
- 121.4 m
- To
- 131.55 m
- Intercept Depth
- 121.4 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-001:121.4-131.55
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 435
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a significant true width, indicating robust mineralization and contributing positively to the project's potential.
Positive factors
- Moderate gold grade over a significant true width.
- Part of a program extending mineralization.
Evidence · table
“1.80”
Context: 10.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.11
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-001Terronera Operation · silverGrade: 282Grade Unit: g/tIntercept: 10.15 mView all detailsHide details
Identity
- Hole ID
- TRU-001
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 282
- Grade Unit
- g/t
- Intercept
- 10.15 m
- True Width
- 8.11 m
- From
- 121.4 m
- To
- 131.55 m
- Intercept Depth
- 121.4 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-001:121.4-131.55
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 435
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade over a significant true width, indicating robust mineralization and contributing positively to the project's potential.
Positive factors
- Strong silver grade over a significant true width.
- Part of a program extending mineralization.
Evidence · table
“282”
Context: 10.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.11
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-001Terronera Operation · goldGrade: 0.49Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- TRU-001
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.04 m
- From
- 122.2 m
- To
- 123.5 m
- Intercept Depth
- 122.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-001:122.2-123.5
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1332
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a weak gold grade over a good true width, which is not particularly material.
Positive factors
- True width reported.
Negative factors
- Weak gold grade.
Evidence · table
“0.49”
Context: 1.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-001Terronera Operation · silverGrade: 1290Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- TRU-001
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1290
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.04 m
- From
- 122.2 m
- To
- 123.5 m
- Intercept Depth
- 122.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-001:122.2-123.5
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1332
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptionally high silver grade, suggesting very high-grade zones within the broader intercept.
Positive factors
- Exceptional silver grade within a high-grade zone.
- True width reported.
- Confirms very high-grade core within the broader intercept.
Evidence · table
“1290”
Context: 1.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-002Terronera Operation · goldGrade: 2.07Grade Unit: g/tIntercept: 6.7 mView all detailsHide details
Identity
- Hole ID
- TRU-002
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 2.07
- Grade Unit
- g/t
- Intercept
- 6.7 m
- True Width
- 5.09 m
- From
- 125.8 m
- To
- 132.5 m
- Intercept Depth
- 125.8 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-002:125.8-132.5
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 256
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good true width, contributing positively to the overall understanding of the mineralization.
Positive factors
- Moderate gold grade over a good true width.
- Part of a program extending mineralization.
Evidence · table
“2.07”
Context: 6.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.09
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-002Terronera Operation · silverGrade: 80Grade Unit: g/tIntercept: 6.7 mView all detailsHide details
Identity
- Hole ID
- TRU-002
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 80
- Grade Unit
- g/t
- Intercept
- 6.7 m
- True Width
- 5.09 m
- From
- 125.8 m
- To
- 132.5 m
- Intercept Depth
- 125.8 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-002:125.8-132.5
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 256
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“80”
Context: 6.70
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.09
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-002Terronera Operation · goldGrade: 3.24Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- TRU-002
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.24
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.46 m
- From
- 131.9 m
- To
- 132.5 m
- Intercept Depth
- 131.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-002:131.9-132.5
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 472
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade over a narrow true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Moderate gold grade.
- True width reported.
- Confirms high-grade core within the broader intercept.
Evidence · table
“3.24”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.46
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-002Terronera Operation · silverGrade: 197Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- TRU-002
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 197
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.46 m
- From
- 131.9 m
- To
- 132.5 m
- Intercept Depth
- 131.9 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-002:131.9-132.5
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 472
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, confirming a higher-grade zone within the broader intercept.
Positive factors
- Moderate silver grade.
- True width reported.
- Confirms high-grade core within the broader intercept.
Evidence · table
“197”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.46
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-003Terronera Operation · goldGrade: 6.3Grade Unit: g/tIntercept: 9.4 mView all detailsHide details
Identity
- Hole ID
- TRU-003
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 6.3
- Grade Unit
- g/t
- Intercept
- 9.4 m
- True Width
- 5.32 m
- From
- 109.2 m
- To
- 118.6 m
- Intercept Depth
- 109.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-003:109.2-118.6
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 686
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows an exceptional gold grade over a good true width, indicating strong mineralization and contributing significantly to the project's potential.
Positive factors
- Exceptional gold grade for an underground mining method.
- Good true width reported.
- Part of a program extending mineralization.
Evidence · table
“6.30”
Context: 9.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.32
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-003Terronera Operation · silverGrade: 150Grade Unit: g/tIntercept: 9.4 mView all detailsHide details
Identity
- Hole ID
- TRU-003
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 150
- Grade Unit
- g/t
- Intercept
- 9.4 m
- True Width
- 5.32 m
- From
- 109.2 m
- To
- 118.6 m
- Intercept Depth
- 109.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-003:109.2-118.6
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 686
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a good true width, contributing to the overall understanding of the mineralization.
Positive factors
- Moderate silver grade.
- Good true width reported.
Evidence · table
“150”
Context: 9.40
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 5.32
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-003Terronera Operation · goldGrade: 12.7Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- TRU-003
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 12.7
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.34 m
- From
- 110.2 m
- To
- 110.8 m
- Intercept Depth
- 110.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- TRU-003:110.2-110.8
- Mining Method
- underground
Location
- Location
- Terronera
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1320
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: This sub-interval highlights an exceptional gold grade, suggesting high-grade zones within the broader intercept, which is positive for potential selective mining.
Positive factors
- Exceptional gold grade within a narrower interval.
- True width reported.
- Indicates high-grade pockets within the broader mineralization.
Evidence · table
“12.70”
Context: 0.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.34
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-003Terronera Operation · silverGrade: 240Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- TRU-003
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 240
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.34 m
- From
- 110.2 m
- To
- 110.8 m
- Intercept Depth
- 110.2 m
Classification
- Sample Type
- drill
- Group ID
- TRU-003:110.2-110.8
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1320
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 240 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 144.0 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 240 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“240”
Context: TRU-003
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.34
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-004Terronera Operation · goldGrade: 4.05Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- TRU-004
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 4.05
- Grade Unit
- g/t
- Intercept
- 6 m
- True Width
- 4.42 m
- From
- 86.4 m
- To
- 92.4 m
- Intercept Depth
- 86.4 m
Classification
- Sample Type
- drill
- Group ID
- TRU-004:86.4-92.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 463
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 4.05 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 24.3 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.05”
Context: TRU-004
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-004Terronera Operation · silverGrade: 119Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- TRU-004
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 119
- Grade Unit
- g/t
- Intercept
- 6 m
- True Width
- 4.42 m
- From
- 86.4 m
- To
- 92.4 m
- Intercept Depth
- 86.4 m
Classification
- Sample Type
- drill
- Group ID
- TRU-004:86.4-92.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 463
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 119 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 714.0 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“119”
Context: TRU-004
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.42
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-004Terronera Operation · goldGrade: 9.29Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- TRU-004
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 9.29
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 0.81 m
- From
- 88.8 m
- To
- 89.9 m
- Intercept Depth
- 88.8 m
Classification
- Sample Type
- drill
- Group ID
- TRU-004:88.8-89.9
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 994
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 9.29 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.2 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 9.29 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“9.29”
Context: TRU-004
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.81
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-004Terronera Operation · silverGrade: 204Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- TRU-004
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 204
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 0.81 m
- From
- 88.8 m
- To
- 89.9 m
- Intercept Depth
- 88.8 m
Classification
- Sample Type
- drill
- Group ID
- TRU-004:88.8-89.9
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 994
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 204 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 224.4 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 204 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“204”
Context: TRU-004
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.81
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-005Terronera Operation · goldGrade: 1.93Grade Unit: g/tIntercept: 9.25 mView all detailsHide details
Identity
- Hole ID
- TRU-005
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.93
- Grade Unit
- g/t
- Intercept
- 9.25 m
- True Width
- 4.2 m
- From
- 150.25 m
- To
- 159.5 m
- Intercept Depth
- 150.25 m
Classification
- Sample Type
- drill
- Group ID
- TRU-005:150.25-159.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 380
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 1.93 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 17.9 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.93”
Context: TRU-005
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-005Terronera Operation · silverGrade: 216Grade Unit: g/tIntercept: 9.25 mView all detailsHide details
Identity
- Hole ID
- TRU-005
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 216
- Grade Unit
- g/t
- Intercept
- 9.25 m
- True Width
- 4.2 m
- From
- 150.25 m
- To
- 159.5 m
- Intercept Depth
- 150.25 m
Classification
- Sample Type
- drill
- Group ID
- TRU-005:150.25-159.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 380
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 216 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 1998.0 g/t·m is moderate (grade alone is strong; the better of the two is used).
Positive factors
- 216 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“216”
Context: TRU-005
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-005Terronera Operation · goldGrade: 1.19Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- TRU-005
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.19
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.27 m
- From
- 151.45 m
- To
- 152.05 m
- Intercept Depth
- 151.45 m
Classification
- Sample Type
- drill
- Group ID
- TRU-005:151.45-152.05
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1025
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 1.19 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 1.19 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.19”
Context: TRU-005
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.27
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-005Terronera Operation · silverGrade: 924Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- TRU-005
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 924
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.27 m
- From
- 151.45 m
- To
- 152.05 m
- Intercept Depth
- 151.45 m
Classification
- Sample Type
- drill
- Group ID
- TRU-005:151.45-152.05
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1025
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 924 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 554.4 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 924 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“924”
Context: TRU-005
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.27
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-006Terronera Operation · goldGrade: 3.1Grade Unit: g/tIntercept: 6.6 mView all detailsHide details
Identity
- Hole ID
- TRU-006
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.1
- Grade Unit
- g/t
- Intercept
- 6.6 m
- True Width
- 2.2 m
- From
- 201.7 m
- To
- 208.3 m
- Intercept Depth
- 201.7 m
Classification
- Sample Type
- drill
- Group ID
- TRU-006:201.7-208.3
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 393
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 3.1 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 20.5 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.10”
Context: TRU-006
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-006Terronera Operation · silverGrade: 130Grade Unit: g/tIntercept: 6.6 mView all detailsHide details
Identity
- Hole ID
- TRU-006
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 130
- Grade Unit
- g/t
- Intercept
- 6.6 m
- True Width
- 2.2 m
- From
- 201.7 m
- To
- 208.3 m
- Intercept Depth
- 201.7 m
Classification
- Sample Type
- drill
- Group ID
- TRU-006:201.7-208.3
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 393
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 130 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 858.0 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“130”
Context: TRU-006
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-006Terronera Operation · goldGrade: 14.7Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- TRU-006
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 14.7
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.27 m
- From
- 204.6 m
- To
- 205.4 m
- Intercept Depth
- 204.6 m
Classification
- Sample Type
- drill
- Group ID
- TRU-006:204.6-205.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1490
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 14.7 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 11.8 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 14.7 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“14.70”
Context: TRU-006
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.27
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-006Terronera Operation · silverGrade: 240Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- TRU-006
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 240
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.27 m
- From
- 204.6 m
- To
- 205.4 m
- Intercept Depth
- 204.6 m
Classification
- Sample Type
- drill
- Group ID
- TRU-006:204.6-205.4
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1490
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 240 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 192.0 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 240 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“240”
Context: TRU-006
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.27
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-007Terronera Operation · goldGrade: 1.33Grade Unit: g/tIntercept: 4.85 mView all detailsHide details
Identity
- Hole ID
- TRU-007
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 1.33
- Grade Unit
- g/t
- Intercept
- 4.85 m
- True Width
- 1.82 m
- From
- 182.45 m
- To
- 187.3 m
- Intercept Depth
- 182.45 m
Classification
- Sample Type
- drill
- Group ID
- TRU-007:182.45-187.3
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 211
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 1.33 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 6.5 g/t·m is below.
Negative factors
- 1.33 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.33”
Context: TRU-007
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-007Terronera Operation · silverGrade: 99Grade Unit: g/tIntercept: 4.85 mView all detailsHide details
Identity
- Hole ID
- TRU-007
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 99
- Grade Unit
- g/t
- Intercept
- 4.85 m
- True Width
- 1.82 m
- From
- 182.45 m
- To
- 187.3 m
- Intercept Depth
- 182.45 m
Classification
- Sample Type
- drill
- Group ID
- TRU-007:182.45-187.3
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 211
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 99 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 480.1 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“99”
Context: TRU-007
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-007Terronera Operation · goldGrade: 5.02Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- TRU-007
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 5.02
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.11 m
- From
- 182.45 m
- To
- 182.75 m
- Intercept Depth
- 182.45 m
Classification
- Sample Type
- drill
- Group ID
- TRU-007:182.45-182.75
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 538
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 5.02 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.5 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.02”
Context: TRU-007
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.11
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-007Terronera Operation · silverGrade: 111Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- TRU-007
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 111
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.11 m
- From
- 182.45 m
- To
- 182.75 m
- Intercept Depth
- 182.45 m
Classification
- Sample Type
- drill
- Group ID
- TRU-007:182.45-182.75
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 538
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 111 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 33.3 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“111”
Context: TRU-007
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.11
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-008Terronera Operation · goldGrade: 5.5Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- TRU-008
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 5.5
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 2.07 m
- From
- 156.5 m
- To
- 161.5 m
- Intercept Depth
- 156.5 m
Classification
- Sample Type
- drill
- Group ID
- TRU-008:156.5-161.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 624
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 5.5 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 27.5 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.50”
Context: TRU-008
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-008Terronera Operation · silverGrade: 156Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- TRU-008
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 156
- Grade Unit
- g/t
- Intercept
- 5 m
- True Width
- 2.07 m
- From
- 156.5 m
- To
- 161.5 m
- Intercept Depth
- 156.5 m
Classification
- Sample Type
- drill
- Group ID
- TRU-008:156.5-161.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 624
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 156 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 780.0 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“156”
Context: TRU-008
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-008Terronera Operation · goldGrade: 14.6Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- TRU-008
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 14.6
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.31 m
- From
- 159.5 m
- To
- 160.25 m
- Intercept Depth
- 159.5 m
Classification
- Sample Type
- drill
- Group ID
- TRU-008:159.5-160.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1594
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 14.6 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.9 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 14.6 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“14.60”
Context: TRU-008
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.31
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-008Terronera Operation · silverGrade: 353Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- TRU-008
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 353
- Grade Unit
- g/t
- Intercept
- 0.75 m
- True Width
- 0.31 m
- From
- 159.5 m
- To
- 160.25 m
- Intercept Depth
- 159.5 m
Classification
- Sample Type
- drill
- Group ID
- TRU-008:159.5-160.25
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1594
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 353 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 264.8 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 353 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“353”
Context: TRU-008
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.31
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-009Terronera Operation · goldGrade: 3.41Grade Unit: g/tIntercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- TRU-009
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 3.41
- Grade Unit
- g/t
- Intercept
- 8.8 m
- True Width
- 4.2 m
- From
- 147.1 m
- To
- 155.9 m
- Intercept Depth
- 147.1 m
Classification
- Sample Type
- drill
- Group ID
- TRU-009:147.1-155.9
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 379
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 3.41 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 30.0 g/t·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.41”
Context: TRU-009
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-009Terronera Operation · silverGrade: 89Grade Unit: g/tIntercept: 8.8 mView all detailsHide details
Identity
- Hole ID
- TRU-009
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 89
- Grade Unit
- g/t
- Intercept
- 8.8 m
- True Width
- 4.2 m
- From
- 147.1 m
- To
- 155.9 m
- Intercept Depth
- 147.1 m
Classification
- Sample Type
- drill
- Group ID
- TRU-009:147.1-155.9
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 379
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 89 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 783.2 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“89”
Context: TRU-009
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.2
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-009Terronera Operation · goldGrade: 13.5Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- TRU-009
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 13.5
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.38 m
- From
- 147.9 m
- To
- 148.7 m
- Intercept Depth
- 147.9 m
Classification
- Sample Type
- drill
- Group ID
- TRU-009:147.9-148.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1468
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 13.5 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.8 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 13.5 g/t gold is strong on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13.50”
Context: TRU-009
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.38
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-009Terronera Operation · silverGrade: 320Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- TRU-009
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 320
- Grade Unit
- g/t
- Intercept
- 0.8 m
- True Width
- 0.38 m
- From
- 147.9 m
- To
- 148.7 m
- Intercept Depth
- 147.9 m
Classification
- Sample Type
- drill
- Group ID
- TRU-009:147.9-148.7
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1468
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 320 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 256.0 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 320 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“320”
Context: TRU-009
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.38
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-010Terronera Operation · goldGrade: 0.09Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- TRU-010
- Project
- Terronera Operation
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 3.3 m
- True Width
- 0.99 m
- From
- 208.2 m
- To
- 211.5 m
- Intercept Depth
- 208.2 m
Classification
- Sample Type
- drill
- Group ID
- TRU-010:208.2-211.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 21
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: TRU-010
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.99
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
TRU-010Terronera Operation · silverGrade: 14Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- TRU-010
- Project
- Terronera Operation
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- EDR
Geometry
- Grade
- 14
- Grade Unit
- g/t
- Intercept
- 3.3 m
- True Width
- 0.99 m
- From
- 208.2 m
- To
- 211.5 m
- Intercept Depth
- 208.2 m
Classification
- Sample Type
- drill
- Group ID
- TRU-010:208.2-211.5
- Mining Method
- underground
Location
- Location
- La Luz
- Loc. Source
- document
QA/QC
- Laboratory
- ALS and SGS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 21
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-06-18T00:00:00.000Z
Reasoning: Expanded from assay table. 14 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 46.2 g/t·m is below.
Negative factors
- 14 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“14”
Context: TRU-010
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.99
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At La Luz, drilling has focused on defining the limits of mineralization adjacent to historical workings and testing the"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.