Equity Metals Extends the No 3 Vein to Depth at the Silver Queen Property, BC

Original announcement by tmx on

Company
Equity Metals Corporation
Ticker
EQTY
Exchange
TSX
Region
British Columbia
Primary commodity
Silver
Secondary commodities
Gold, Copper, Lead, Zinc
Document categories
Drill results
Extracted
2026-09-13 22:50:33 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Equity Metals Corporation reported new drill results from its Silver Queen Au-Ag project in British Columbia, extending the No. 3 Vein mineralization to depth and along strike. Highlights include high-grade gold, silver, copper, lead, and zinc intercepts, which are expected to be accretive to the existing mineral resource. The results will be incorporated into a revised resource model for an update in Q1 2026.

Reasoning: The drill program successfully extended high-grade precious and base metal mineralization at depth and along strike, supporting a future resource update with transparent reporting.

Positive factors

  • High-grade intercepts
  • Extension of mineralization
  • QP/CP Signed
  • QA/QC Disclosed
  • Compositing Transparent
  • Supports future resource update

Facts used in scoring: 110

Classification and evidence

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The document explicitly states 'ETT (m)' in the table and 'Est. TT' in the prose, indicating estimated true thickness.

Evidence · text

“A 1.3 metre (Est. TT) interval”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The drill program successfully extended mineralization along strike and to depth beyond previous limits.

Evidence · text

“continue to extend the projection of mineralization in the No. 3 Vein beyond the limits of the Company's 2022 Resource Estimate.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release mentions the laboratory, overlimit assay procedures, and the systematic inclusion of standards, blanks, and duplicates, along with QP sign-off.

Evidence · text

“drill core samples were analyzed by FA/AAS for gold and 48 element ICP-MS by MS Analytical, Langley, BC. ... Accuracy of results is tested through the systematic inclusion of QA/QC standards, blanks and duplicates into the sample stream.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: The cut-off grade and internal dilution rules used for downhole composites are clearly stated.

Evidence · text

“Downhole composites calculated using a 80g/t AgEq (1g/t AuEq) cut-off and <20% internal dilution, except where noted.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The program aimed to 'expand and develop continuity within the vein sets and is accretive to previously modelled mineral resources'.

Evidence · text

“Mineralization identified in the current drill program continues to expand and develop continuity within the vein sets and is accretive to previously modelled mineral resources on the Silver Queen Project.”

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept SQ25-160 (inc.) returned 28.2 g/t AuEq over 0.7m, which is well above the exceptional threshold for epithermal gold deposits.

Evidence · table

“28.2”

Context: 0.8

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept SQ25-164 (inc.) returned 37.1 g/t AuEq over 0.4m, which is well above the exceptional threshold for epithermal gold deposits.

Evidence · table

“37.1”

Context: 0.5

Extracted facts

Stored fact records: 110. Some facts used in scoring do not have a stored record.

Drill Results (110)

SQ25-160Silver Queen · silverGrade: 280Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
280
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
344 m
To
344.5 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:344-344.5
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
6.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A high-grade silver intercept with good gold equivalent value, contributing to the extension of mineralization.

Positive factors

  • High-grade intercept
  • True Width Disclosed

Evidence · table

“280”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · silverGrade: 471Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
471
Grade Unit
g/t
Intercept
1.5 m
True Width
1.3 m
From
355 m
To
356.5 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:355-356.5
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
15.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A strong polymetallic intercept with high silver and gold equivalent grades, indicating significant mineralization.

Positive factors

  • High-grade intercept
  • True Width Disclosed
  • Strong gold equivalent

Evidence · table

“471”

Context: 1.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · silverGrade: 890Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
890
Grade Unit
g/t
Intercept
0.8 m
True Width
0.7 m
From
355.7 m
To
356.5 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:355.7-356.5
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
28.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: An exceptionally high-grade polymetallic sub-interval with bonanza silver and gold equivalent values, indicating a very rich zone.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • Exceptional gold equivalent

Evidence · table

“890”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · silverGrade: 33Grade Unit: g/tIntercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
33
Grade Unit
g/t
Intercept
7.5 m
True Width
6.3 m
From
390.9 m
To
398.4 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:390.9-398.4
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
1.8
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A moderate-grade polymetallic intercept over a good width, contributing to overall resource continuity.

Positive factors

  • True Width Disclosed

Evidence · table

“33”

Context: 7.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · silverGrade: 78Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
78
Grade Unit
g/t
Intercept
2.8 m
True Width
2.3 m
From
393.3 m
To
396 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:393.3-396
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic sub-interval with strong gold equivalent value, enhancing the overall intercept.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“78”

Context: 2.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · silverGrade: 327Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
327
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
393.3 m
To
393.8 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:393.3-393.8
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
16.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A high-grade polymetallic sub-interval with significant silver and gold equivalent values, contributing to the overall prospectivity.

Positive factors

  • High-grade intercept
  • True Width Disclosed
  • Strong gold equivalent

Evidence · table

“327”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · silverGrade: 130Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
130
Grade Unit
g/t
Intercept
1.1 m
True Width
0.9 m
From
405.6 m
To
406.6 m
Hole Depth
477 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-160:405.6-406.6
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995992
Elevation
949 m
Azimuth
195 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
5.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic intercept with strong gold equivalent value, extending mineralization at depth.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“130”

Context: 1.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · silverGrade: 129Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
129
Grade Unit
g/t
Intercept
0.6 m
True Width
0.4 m
From
329.5 m
To
330.2 m
Hole Depth
477 m
Intercept Depth
329.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-161:329.5-330.2
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
204 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A moderate-grade polymetallic intercept, contributing to the understanding of the vein system.

Positive factors

  • True Width Disclosed

Evidence · table

“129”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · silverGrade: 134Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
134
Grade Unit
g/t
Intercept
1.9 m
True Width
1.2 m
From
432.6 m
To
434.6 m
Hole Depth
477 m
Intercept Depth
329.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-161:432.6-434.6
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
204 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A moderate-grade polymetallic intercept, contributing to the understanding of the vein system.

Positive factors

  • True Width Disclosed

Evidence · table

“134”

Context: 1.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · silverGrade: 804Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
804
Grade Unit
g/t
Intercept
0.8 m
True Width
0.6 m
From
457.6 m
To
458.4 m
Hole Depth
558 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-162:457.6-458.4
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
192 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
25.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: An exceptionally high-grade polymetallic intercept with bonanza silver and gold equivalent values, indicating a very rich zone at depth.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • Exceptional gold equivalent

Evidence · table

“804”

Context: 0.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · silverGrade: 60Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
60
Grade Unit
g/t
Intercept
0.9 m
True Width
0.7 m
From
465.7 m
To
466.6 m
Hole Depth
558 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-162:465.7-466.6
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
192 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
4.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic intercept with strong gold equivalent value, contributing to the overall prospectivity.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“60”

Context: 0.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · silverGrade: 40Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
40
Grade Unit
g/t
Intercept
1.2 m
True Width
0.9 m
From
469.8 m
To
471 m
Hole Depth
558 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-162:469.8-471
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
192 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
3.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A moderate-grade polymetallic intercept, contributing to the understanding of the vein system.

Positive factors

  • True Width Disclosed

Evidence · table

“40”

Context: 1.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · silverGrade: 55Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
55
Grade Unit
g/t
Intercept
0.6 m
True Width
0.5 m
From
469.8 m
To
470.4 m
Hole Depth
558 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-162:469.8-470.4
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
192 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
4.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic sub-interval with strong gold equivalent value, enhancing the overall intercept.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“55”

Context: 0.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · silverGrade: 85Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
85
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
543.9 m
To
544.5 m
Hole Depth
558 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-162:543.9-544.5
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648968
Northing
5995993
Elevation
948 m
Azimuth
192 °
Dip
-58 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
4.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic intercept with strong gold equivalent value, contributing to the overall prospectivity.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“85”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · silverGrade: 118Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
118
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
330 m
To
330.4 m
Hole Depth
537 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-164:330-330.4
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
217 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
6.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic intercept with strong gold equivalent value, contributing to the overall prospectivity.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“118”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · silverGrade: 17Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
17
Grade Unit
g/t
Intercept
1.3 m
True Width
1 m
From
393 m
To
394.3 m
Hole Depth
537 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-164:393-394.3
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
217 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
2.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A low-grade polymetallic intercept, contributing to the understanding of the vein system.

Positive factors

  • True Width Disclosed

Evidence · table

“17”

Context: 1.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · silverGrade: 519Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
519
Grade Unit
g/t
Intercept
2.1 m
True Width
1.7 m
From
450 m
To
452.1 m
Hole Depth
537 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-164:450-452.1
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
217 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
12.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A strong polymetallic intercept with high silver and gold equivalent grades, indicating significant mineralization.

Positive factors

  • High-grade intercept
  • True Width Disclosed
  • Strong gold equivalent

Evidence · table

“519”

Context: 2.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · silverGrade: 2026Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2026
Grade Unit
g/t
Intercept
0.5 m
True Width
0.4 m
From
450.5 m
To
450.9 m
Hole Depth
537 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-164:450.5-450.9
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
217 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
37.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: An exceptionally high-grade polymetallic sub-interval with bonanza silver and gold equivalent values, indicating a very rich zone.

Positive factors

  • Bonanza Intercept
  • True Width Disclosed
  • Exceptional gold equivalent

Evidence · table

“2026”

Context: 0.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · silverGrade: 18Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
18
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
433.8 m
To
434.2 m
Hole Depth
582 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-165:433.8-434.2
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
228 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
4.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic intercept with strong gold equivalent value, contributing to the overall prospectivity.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“18”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · silverGrade: 65Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
65
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
507.9 m
To
508.3 m
Hole Depth
582 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-165:507.9-508.3
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
228 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
4.8
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A good polymetallic intercept with strong gold equivalent value, contributing to the overall prospectivity.

Positive factors

  • High-grade gold equivalent
  • True Width Disclosed

Evidence · table

“65”

Context: 0.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · silverGrade: 47Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
47
Grade Unit
g/t
Intercept
1.5 m
True Width
1 m
From
511.4 m
To
512.9 m
Hole Depth
582 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
SQ25-165:511.4-512.9
Mining Method
underground

Location

Location
No. 3 Vein
Easting
648969
Northing
5995993
Elevation
948 m
Azimuth
228 °
Dip
-56 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Metal Eq. Grade
2.8
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: A moderate-grade polymetallic intercept, contributing to the understanding of the vein system.

Positive factors

  • True Width Disclosed

Evidence · table

“47”

Context: 1.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · goldGrade: 1.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
0.5 m
From
344 m
To
344.5 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:344-344.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
473
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 1.4 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.4”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · copperGrade: 0.8Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.8
Grade Unit
%
Intercept
0.5 m
From
344 m
To
344.5 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:344-344.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
473
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.8”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · leadGrade: 0.1Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.5 m
From
344 m
To
344.5 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:344-344.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
473
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · zincGrade: 0.2Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.5 m
From
344 m
To
344.5 m
Intercept Depth
344 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:344-344.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
473
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.2 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · goldGrade: 4.7Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
4.7
Grade Unit
g/t
Intercept
1.5 m
From
355 m
To
356.5 m
Intercept Depth
355 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:355-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1128
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.7 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 7.1 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.7”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · copperGrade: 2.5Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2.5
Grade Unit
%
Intercept
1.5 m
From
355 m
To
356.5 m
Intercept Depth
355 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:355-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1128
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 3.8 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 2.5 % copper is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.5”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · leadGrade: 0.3Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.3
Grade Unit
%
Intercept
1.5 m
From
355 m
To
356.5 m
Intercept Depth
355 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:355-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1128
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.3 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.3”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · zincGrade: 1.5Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.5
Grade Unit
%
Intercept
1.5 m
From
355 m
To
356.5 m
Intercept Depth
355 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:355-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1128
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.3 %·m is below.

Negative factors

  • 1.5 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.5”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · goldGrade: 8.9Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
8.9
Grade Unit
g/t
Intercept
0.8 m
From
355.7 m
To
356.5 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:355.7-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2042
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 8.9 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 7.1 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 8.9 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.9”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · silverGrade: 890Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
890
Grade Unit
g/t
Intercept
0.8 m
From
355.7 m
To
356.5 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:355.7-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2042
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 890 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 712.0 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 890 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“890”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · copperGrade: 4.8Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
4.8
Grade Unit
%
Intercept
0.8 m
From
355.7 m
To
356.5 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:355.7-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2042
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.8 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 3.8 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 4.8 % copper is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.8”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · leadGrade: 0.3Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.8 m
From
355.7 m
To
356.5 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:355.7-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2042
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.3 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.3”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · zincGrade: 0.2Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.8 m
From
355.7 m
To
356.5 m
Intercept Depth
355.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:355.7-356.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2042
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.2 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · goldGrade: 0.4Grade Unit: g/tIntercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
7.5 m
From
390.9 m
To
398.4 m
Intercept Depth
390.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:390.9-398.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
127
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 3.0 g/t·m is below.

Negative factors

  • 0.4 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.4”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · copperGrade: 0.2Grade Unit: %Intercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
7.5 m
From
390.9 m
To
398.4 m
Intercept Depth
390.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:390.9-398.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
127
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.5 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · leadGrade: 0.1Grade Unit: %Intercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
7.5 m
From
390.9 m
To
398.4 m
Intercept Depth
390.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:390.9-398.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
127
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.8 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · zincGrade: 1.2Grade Unit: %Intercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.2
Grade Unit
%
Intercept
7.5 m
From
390.9 m
To
398.4 m
Intercept Depth
390.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:390.9-398.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
127
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 9.0 %·m is below.

Negative factors

  • 1.2 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.2”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · goldGrade: 0.8Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.8
Grade Unit
g/t
Intercept
2.8 m
From
393.3 m
To
396 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-396
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
292
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.2 g/t·m is below.

Negative factors

  • 0.8 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.8”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · silverGrade: 78Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
78
Grade Unit
g/t
Intercept
2.8 m
From
393.3 m
To
396 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-396
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
292
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 78 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 218.4 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“78”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · copperGrade: 0.4Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.4
Grade Unit
%
Intercept
2.8 m
From
393.3 m
To
396 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-396
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
292
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.4”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · leadGrade: 0.2Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
2.8 m
From
393.3 m
To
396 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-396
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
292
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.6 %·m is below.

Negative factors

  • 0.2 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · zincGrade: 3.2Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
3.2
Grade Unit
%
Intercept
2.8 m
From
393.3 m
To
396 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-396
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
292
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.2 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 9.0 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.2”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · goldGrade: 2.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2.5
Grade Unit
g/t
Intercept
0.5 m
From
393.3 m
To
393.8 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-393.8
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.5”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · silverGrade: 327Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
327
Grade Unit
g/t
Intercept
0.5 m
From
393.3 m
To
393.8 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-393.8
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 327 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 163.5 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 327 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“327”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · copperGrade: 1.7Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.7
Grade Unit
%
Intercept
0.5 m
From
393.3 m
To
393.8 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-393.8
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.8 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.7 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.7”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · leadGrade: 0.9Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.9
Grade Unit
%
Intercept
0.5 m
From
393.3 m
To
393.8 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-393.8
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.5 %·m is below.

Negative factors

  • 0.9 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.9”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · zincGrade: 15.9Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
15.9
Grade Unit
%
Intercept
0.5 m
From
393.3 m
To
393.8 m
Intercept Depth
393.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:393.3-393.8
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1223
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 15.9 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 8.0 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 15.9 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.9”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · goldGrade: 0.6Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
1.1 m
From
405.6 m
To
406.6 m
Intercept Depth
405.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:405.6-406.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
376
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 0.6 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · copperGrade: 1.5Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.5
Grade Unit
%
Intercept
1.1 m
From
405.6 m
To
406.6 m
Intercept Depth
405.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:405.6-406.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
376
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.7 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.5 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.5”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · leadGrade: 0.5Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.5
Grade Unit
%
Intercept
1.1 m
From
405.6 m
To
406.6 m
Intercept Depth
405.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:405.6-406.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
376
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.6 %·m is below.

Negative factors

  • 0.5 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-160Silver Queen · zincGrade: 1.2Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-160
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.2
Grade Unit
%
Intercept
1.1 m
From
405.6 m
To
406.6 m
Intercept Depth
405.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-160:405.6-406.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
376
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.3 %·m is below.

Negative factors

  • 1.2 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.2”

Context: SQ25-160

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · goldGrade: 0.2Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
0.6 m
From
329.5 m
To
330.2 m
Intercept Depth
329.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:329.5-330.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
239
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · copperGrade: 0.2Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.6 m
From
329.5 m
To
330.2 m
Intercept Depth
329.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:329.5-330.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
239
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · leadGrade: 1.8Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.8
Grade Unit
%
Intercept
0.6 m
From
329.5 m
To
330.2 m
Intercept Depth
329.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:329.5-330.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
239
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.8 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.1 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.8”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · zincGrade: 1Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1
Grade Unit
%
Intercept
0.6 m
From
329.5 m
To
330.2 m
Intercept Depth
329.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:329.5-330.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
239
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below.

Negative factors

  • 1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.0”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · goldGrade: 0.6Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
1.9 m
From
432.6 m
To
434.6 m
Intercept Depth
432.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:432.6-434.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
242
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.1 g/t·m is below.

Negative factors

  • 0.6 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · copperGrade: 0.4Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.4
Grade Unit
%
Intercept
1.9 m
From
432.6 m
To
434.6 m
Intercept Depth
432.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:432.6-434.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
242
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.8 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.4”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · leadGrade: 0.1Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
1.9 m
From
432.6 m
To
434.6 m
Intercept Depth
432.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:432.6-434.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
242
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-161Silver Queen · zincGrade: 0.5Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-161
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.5
Grade Unit
%
Intercept
1.9 m
From
432.6 m
To
434.6 m
Intercept Depth
432.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-161:432.6-434.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
242
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.9 %·m is below.

Negative factors

  • 0.5 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: SQ25-161

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · goldGrade: 7.7Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
7.7
Grade Unit
g/t
Intercept
0.8 m
From
457.6 m
To
458.4 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:457.6-458.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1845
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7.7 g/t gold is strong against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 6.2 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 7.7 g/t gold is strong on the underground mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.7”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · copperGrade: 4.7Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
4.7
Grade Unit
%
Intercept
0.8 m
From
457.6 m
To
458.4 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:457.6-458.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1845
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.7 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 3.8 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 4.7 % copper is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.7”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · leadGrade: 0.2Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.8 m
From
457.6 m
To
458.4 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:457.6-458.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1845
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.2 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · zincGrade: 0.1Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.8 m
From
457.6 m
To
458.4 m
Intercept Depth
457.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:457.6-458.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1845
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · goldGrade: 1.9Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
0.9 m
From
465.7 m
To
466.6 m
Intercept Depth
465.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:465.7-466.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
327
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.7 g/t·m is below.

Negative factors

  • 1.9 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.9”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · copperGrade: 1.2Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.2
Grade Unit
%
Intercept
0.9 m
From
465.7 m
To
466.6 m
Intercept Depth
465.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:465.7-466.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
327
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.1 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.2 % copper is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · leadGrade: 0Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0
Grade Unit
%
Intercept
0.9 m
From
465.7 m
To
466.6 m
Intercept Depth
465.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:465.7-466.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
327
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · zincGrade: 0.2Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
0.9 m
From
465.7 m
To
466.6 m
Intercept Depth
465.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:465.7-466.6
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
327
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.2 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · goldGrade: 1.9Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
1.2 m
From
469.8 m
To
471 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:469.8-471
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
235
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.3 g/t·m is below.

Negative factors

  • 1.9 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.9”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · copperGrade: 0.2Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
1.2 m
From
469.8 m
To
471 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:469.8-471
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
235
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.2 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · leadGrade: 0.2Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
1.2 m
From
469.8 m
To
471 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:469.8-471
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
235
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.2 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · zincGrade: 1Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1
Grade Unit
%
Intercept
1.2 m
From
469.8 m
To
471 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:469.8-471
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
235
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.2 %·m is below.

Negative factors

  • 1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.0”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · goldGrade: 3.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
3.4
Grade Unit
g/t
Intercept
0.6 m
From
469.8 m
To
470.4 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:469.8-470.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
353
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.4”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · silverGrade: 55Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
55
Grade Unit
g/t
Intercept
0.6 m
From
469.8 m
To
470.4 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:469.8-470.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
353
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 55 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 33.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“55”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · copperGrade: 0.4Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.4
Grade Unit
%
Intercept
0.6 m
From
469.8 m
To
470.4 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:469.8-470.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
353
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.4”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · leadGrade: 0.1Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.6 m
From
469.8 m
To
470.4 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:469.8-470.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
353
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · zincGrade: 0.3Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.6 m
From
469.8 m
To
470.4 m
Intercept Depth
469.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:469.8-470.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
353
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.3 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.3”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · goldGrade: 0.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
0.5 m
From
543.9 m
To
544.5 m
Intercept Depth
543.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:543.9-544.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
319
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.1 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · copperGrade: 0.1Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.5 m
From
543.9 m
To
544.5 m
Intercept Depth
543.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:543.9-544.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
319
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · leadGrade: 5.2Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
5.2
Grade Unit
%
Intercept
0.5 m
From
543.9 m
To
544.5 m
Intercept Depth
543.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:543.9-544.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
319
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 2.6 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-162Silver Queen · zincGrade: 3.2Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-162
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
3.2
Grade Unit
%
Intercept
0.5 m
From
543.9 m
To
544.5 m
Intercept Depth
543.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-162:543.9-544.5
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
319
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.2 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 1.6 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.2”

Context: SQ25-162

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · goldGrade: 0.3Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
0.4 m
From
330 m
To
330.4 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:330-330.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.3 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.3”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · copperGrade: 2.8Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2.8
Grade Unit
%
Intercept
0.4 m
From
330 m
To
330.4 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:330-330.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.1 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 2.8 % copper is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.8”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · leadGrade: 0.6Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.6
Grade Unit
%
Intercept
0.4 m
From
330 m
To
330.4 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:330-330.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.6 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · zincGrade: 1Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1
Grade Unit
%
Intercept
0.4 m
From
330 m
To
330.4 m
Intercept Depth
330 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:330-330.4
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
477
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.4 %·m is below.

Negative factors

  • 1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.0”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · goldGrade: 1.3Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.3
Grade Unit
g/t
Intercept
1.3 m
From
393 m
To
394.3 m
Intercept Depth
393 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:393-394.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
163
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.7 g/t·m is below.

Negative factors

  • 1.3 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.3”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · copperGrade: 0.1Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
1.3 m
From
393 m
To
394.3 m
Intercept Depth
393 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:393-394.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
163
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · leadGrade: 0.2Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
%
Intercept
1.3 m
From
393 m
To
394.3 m
Intercept Depth
393 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:393-394.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
163
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.2 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · zincGrade: 1.1Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.1
Grade Unit
%
Intercept
1.3 m
From
393 m
To
394.3 m
Intercept Depth
393 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:393-394.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
163
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.4 %·m is below.

Negative factors

  • 1.1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.1”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · goldGrade: 0.2Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
2.1 m
From
450 m
To
452.1 m
Intercept Depth
450 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:450-452.1
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
910
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.4 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · copperGrade: 0.1Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
2.1 m
From
450 m
To
452.1 m
Intercept Depth
450 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:450-452.1
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
910
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · leadGrade: 2.8Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2.8
Grade Unit
%
Intercept
2.1 m
From
450 m
To
452.1 m
Intercept Depth
450 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:450-452.1
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
910
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 5.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.8”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-164Silver Queen · zincGrade: 9.5Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
SQ25-164
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
9.5
Grade Unit
%
Intercept
2.1 m
From
450 m
To
452.1 m
Intercept Depth
450 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-164:450-452.1
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
910
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 9.5 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 19.9 %·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.5”

Context: SQ25-164

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · goldGrade: 0Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0
Grade Unit
g/t
Intercept
0.5 m
From
450.5 m
To
450.9 m
Intercept Depth
450.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:450.5-450.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2687
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · silverGrade: 2026Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
silver
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2026
Grade Unit
g/t
Intercept
0.5 m
From
450.5 m
To
450.9 m
Intercept Depth
450.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:450.5-450.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2687
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2026 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 1013.0 g/t·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 2026 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2026”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · copperGrade: 0.1Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.5 m
From
450.5 m
To
450.9 m
Intercept Depth
450.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:450.5-450.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2687
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.1”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · leadGrade: 7.9Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
7.9
Grade Unit
%
Intercept
0.5 m
From
450.5 m
To
450.9 m
Intercept Depth
450.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:450.5-450.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2687
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7.9 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 4.0 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 7.9 % lead is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.9”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

inc.Silver Queen · zincGrade: 14.5Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
inc.
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
14.5
Grade Unit
%
Intercept
0.5 m
From
450.5 m
To
450.9 m
Intercept Depth
450.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
inc.:450.5-450.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2687
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 14.5 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 7.3 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 14.5 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.5”

Context: inc.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · goldGrade: 0.5Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
0.4 m
From
433.8 m
To
434.2 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:433.8-434.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.5 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · copperGrade: 0Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0
Grade Unit
%
Intercept
0.4 m
From
433.8 m
To
434.2 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:433.8-434.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.25 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.0”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · leadGrade: 0.5Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.5
Grade Unit
%
Intercept
0.4 m
From
433.8 m
To
434.2 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:433.8-434.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.5 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · zincGrade: 7.8Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
7.8
Grade Unit
%
Intercept
0.4 m
From
433.8 m
To
434.2 m
Intercept Depth
433.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:433.8-434.2
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
320
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7.8 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 3.1 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.8”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · goldGrade: 2.1Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2.1
Grade Unit
g/t
Intercept
0.4 m
From
507.9 m
To
508.3 m
Intercept Depth
507.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:507.9-508.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
346
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 2.1 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.1”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · copperGrade: 0.6Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.6
Grade Unit
%
Intercept
0.4 m
From
507.9 m
To
508.3 m
Intercept Depth
507.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:507.9-508.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
346
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · leadGrade: 0.7Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.7
Grade Unit
%
Intercept
0.4 m
From
507.9 m
To
508.3 m
Intercept Depth
507.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:507.9-508.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
346
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.7 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.7”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · zincGrade: 1.6Grade Unit: %Intercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
1.6
Grade Unit
%
Intercept
0.4 m
From
507.9 m
To
508.3 m
Intercept Depth
507.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:507.9-508.3
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
346
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below.

Negative factors

  • 1.6 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.6”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · goldGrade: 0.4Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
gold
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
1.5 m
From
511.4 m
To
512.9 m
Intercept Depth
511.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:511.4-512.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
200
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.6 g/t·m is below.

Negative factors

  • 0.4 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.4”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · copperGrade: 0.3Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
copper
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.3
Grade Unit
%
Intercept
1.5 m
From
511.4 m
To
512.9 m
Intercept Depth
511.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:511.4-512.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
200
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.3”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · leadGrade: 0.6Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
lead
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
0.6
Grade Unit
%
Intercept
1.5 m
From
511.4 m
To
512.9 m
Intercept Depth
511.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:511.4-512.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
200
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.9 %·m is below.

Negative factors

  • 0.6 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

SQ25-165Silver Queen · zincGrade: 2.4Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
SQ25-165
Project
Silver Queen
Commodity
zinc
Region
canada_bc
Reported Region
canada_bc
Ticker
EQTY

Geometry

Grade
2.4
Grade Unit
%
Intercept
1.5 m
From
511.4 m
To
512.9 m
Intercept Depth
511.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
SQ25-165:511.4-512.9
Mining Method
underground

QA/QC

Laboratory
MS Analytical
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
200
Metal Eq. Unit
g/t Eq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 3.6 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.4”

Context: SQ25-165

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "3 Vein is adjacent to historical mine workings, providing potential access advantages in any future development scenario"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.