Equity Metals Reports Shallow Extensions of the No. 3 Vein to the Northwest of Historic Workings, Silver Queen Property, BC
Original announcement by tmx on
- Company
- Equity Metals Corporation
- Ticker
- EQTY
- Exchange
- TSX
- Region
- British Columbia
- Primary commodity
- Silver
- Secondary commodities
- Gold, Copper, Lead, Zinc
- Document categories
- Drill results, Resource update
- Extracted
- 2026-09-13 22:55:59 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Equity Metals reports new drill results from its Summer '25 program at the Silver Queen project in British Columbia, extending the No. 3 Vein mineralization. Highlights include high-grade silver and gold equivalent intercepts, with the program successfully extending the vein up to 650 metres laterally. The company anticipates an updated Mineral Resource Estimate in late Q4 2025.
Reasoning: The drill program successfully extended high-grade gold and silver mineralization along strike and down dip, with several bonanza-grade intercepts, and is expected to lead to a significant resource update.
Positive factors
- High-grade silver and gold equivalent intercepts, some exceeding bonanza thresholds for epithermal deposits.
- Successful extension of the No. 3 Vein mineralization laterally and at depth beyond the previous resource model.
- Transparent disclosure of QA/QC procedures and metal equivalent calculation assumptions.
- Upcoming resource update anticipated in late Q4 2025, indicating potential for resource growth.
Negative factors
- Some high-grade intercepts are over narrow widths.
- Maximum internal dilution is stated as a percentage (<20%) rather than a specific meter value.
Facts used in scoring: 120
Classification and evidence
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document provides an 'ETT (m)' column in the assay table, indicating estimated true width for the reported intercepts.
Evidence · table
“ETT (m)”
Context: Interval (m)
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The drill program is described as extending the lateral projection of the No. 3 North vein beyond the Company's 2022 Resource Estimate.
Evidence · text
“continue to extend the lateral projection of the No. 3 North vein beyond the Company's 2022 Resource Estimate”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release states that 'Accuracy of results is tested through the systematic inclusion of QA/QC standards, blanks and duplicates into the sample stream'.
Evidence · text
“Accuracy of results is tested through the systematic inclusion of QA/QC standards, blanks and duplicates into the sample stream.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: The document clearly states the cut-off grade and internal dilution rules used for compositing: 'Downhole composites calculated using a 80g/t AgEq (1g/t AuEq) cut-off and <20% internal dilution'.
Evidence · text
“Downhole composites calculated using a 80g/t AgEq (1g/t AuEq) cut-off and <20% internal dilution”
QP/CP Signedpositive
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: Robert Macdonald, MSc. P.Geo, is explicitly named as VP Exploration and a Qualified Person responsible for the technical information and approval of the news release.
Evidence · text
“Robert Macdonald, MSc. P.Geo, is VP Exploration of Equity Metals Corporation and a Qualified Person as defined by National Instrument 43-101. He is responsible for the supervision of the exploration on the Silver Queen project and for the preparation of the technical information in this disclosure. He has reviewed and approved this news release.”
Resource Update Plannedpositive · Story-specific tag
No canonical definition is currently available.
Why it applies: The company explicitly states that the current drilling will culminate in an 'updated Mineral Resource Estimate anticipated in late Q4 2025'.
Evidence · text
“culminating in an updated Mineral Resource Estimate anticipated in late Q4 2025”
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Several silver equivalent intercepts, such as 1448 g/t AgEq and 1374 g/t AgEq, are well above the 500 g/t exceptional threshold for epithermal silver deposits.
Evidence · table
“1448”
Context: 0.4
Epithermal Veinneutral · Story-specific tag
No canonical definition is currently available.
Why it applies: The document explicitly states that 'Mineralization is hosted by a series of epithermal veins'.
Evidence · text
“Mineralization is hosted by a series of epithermal veins”
Extracted facts
Stored fact records: 120. Some facts used in scoring do not have a stored record.
Drill Results (120)
SQ25-152Silver Queen Au-Ag · goldGrade: 1.7Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- SQ25-152
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.7
- Grade Unit
- g/t
- Intercept
- 1.2 m
- True Width
- 0.9 m
- From
- 88 m
- To
- 89.2 m
- Hole Depth
- 200 m
- Intercept Depth
- 88 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-152:88-89.2
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648833
- Northing
- 5995703
- Elevation
- 927 m
- Azimuth
- 238 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold grade over a narrow true width, contributing to the overall extension of the vein.
Positive factors
- Good gold grade for an epithermal deposit.
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“1.7”
Context: 1.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-152Silver Queen Au-Ag · silverGrade: 223Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- SQ25-152
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 223
- Grade Unit
- g/t
- Intercept
- 1.2 m
- True Width
- 0.9 m
- From
- 88 m
- To
- 89.2 m
- Hole Depth
- 200 m
- Intercept Depth
- 88 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-152:88-89.2
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648833
- Northing
- 5995703
- Elevation
- 927 m
- Azimuth
- 238 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 592
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver grade over a narrow true width, significantly contributing to the overall high-grade nature of the vein extension.
Positive factors
- Exceptional silver grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“223”
Context: 1.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-152Silver Queen Au-Ag · copperGrade: 1.2Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- SQ25-152
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.2
- Grade Unit
- %
- Intercept
- 1.2 m
- True Width
- 0.9 m
- From
- 88 m
- To
- 89.2 m
- Hole Depth
- 200 m
- Intercept Depth
- 88 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-152:88-89.2
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648833
- Northing
- 5995703
- Elevation
- 927 m
- Azimuth
- 238 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong copper grade over a narrow true width, adding to the polymetallic nature of the mineralization.
Positive factors
- Strong copper grade for an epithermal deposit.
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“1.2”
Context: 1.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-152Silver Queen Au-Ag · leadGrade: 1.3Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- SQ25-152
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.3
- Grade Unit
- %
- Intercept
- 1.2 m
- True Width
- 0.9 m
- From
- 88 m
- To
- 89.2 m
- Hole Depth
- 200 m
- Intercept Depth
- 88 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-152:88-89.2
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648833
- Northing
- 5995703
- Elevation
- 927 m
- Azimuth
- 238 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate lead grade over a narrow true width, contributing to the polymetallic nature of the mineralization.
Positive factors
- Moderate lead grade.
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“1.3”
Context: 1.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-152Silver Queen Au-Ag · zincGrade: 2.9Grade Unit: %Intercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- SQ25-152
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.9
- Grade Unit
- %
- Intercept
- 1.2 m
- True Width
- 0.9 m
- From
- 88 m
- To
- 89.2 m
- Hole Depth
- 200 m
- Intercept Depth
- 88 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-152:88-89.2
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648833
- Northing
- 5995703
- Elevation
- 927 m
- Azimuth
- 238 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate zinc grade over a narrow true width, contributing to the polymetallic nature of the mineralization.
Positive factors
- Moderate zinc grade.
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“2.9”
Context: 1.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · goldGrade: 0.4Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.8 m
- From
- 200.8 m
- To
- 201.8 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:200.8-201.8
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.3
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A low gold grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Low gold grade for an epithermal deposit.
- Narrow intercept length.
Evidence · table
“0.4”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · silverGrade: 87Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 87
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.8 m
- From
- 200.8 m
- To
- 201.8 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:200.8-201.8
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 457
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate silver grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- Moderate silver grade for an epithermal deposit.
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“87”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · copperGrade: 0.3Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.8 m
- From
- 200.8 m
- To
- 201.8 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:200.8-201.8
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.3
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak copper grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak copper grade for an epithermal deposit.
- Narrow intercept length.
Evidence · table
“0.3”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · leadGrade: 0.7Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.8 m
- From
- 200.8 m
- To
- 201.8 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:200.8-201.8
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.3
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak lead grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak lead grade.
- Narrow intercept length.
Evidence · table
“0.7”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · zincGrade: 9.2Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 9.2
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.8 m
- From
- 200.8 m
- To
- 201.8 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:200.8-201.8
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.3
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong zinc grade over a narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Strong zinc grade for an epithermal deposit.
- True width estimated.
Negative factors
- Narrow intercept length.
Evidence · table
“9.2”
Context: 1.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · goldGrade: 0.3Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.6 m
- From
- 320 m
- To
- 322 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:320-322
- Mining Method
- underground
Location
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak gold grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak gold grade for an epithermal deposit.
Evidence · table
“0.3”
Context: 2.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · silverGrade: 200Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 200
- Grade Unit
- g/t
- Intercept
- 2 m
- True Width
- 1.6 m
- From
- 320 m
- To
- 322 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:320-322
- Mining Method
- underground
Location
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 245
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong silver grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- Strong silver grade for an epithermal deposit.
- True width estimated.
Evidence · table
“200”
Context: 2.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · copperGrade: 0Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 2 m
- True Width
- 1.6 m
- From
- 320 m
- To
- 322 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:320-322
- Mining Method
- underground
Location
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A barren copper grade over a moderate true width, indicating localized absence of copper mineralization.
Positive factors
- True width estimated.
Negative factors
- Barren copper grade.
Evidence · table
“0.0”
Context: 2.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · leadGrade: 0.1Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 2 m
- True Width
- 1.6 m
- From
- 320 m
- To
- 322 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:320-322
- Mining Method
- underground
Location
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A very low lead grade over a moderate true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Very low lead grade.
Evidence · table
“0.1”
Context: 2.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · zincGrade: 0.5Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 2 m
- True Width
- 1.6 m
- From
- 320 m
- To
- 322 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:320-322
- Mining Method
- underground
Location
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak zinc grade over a moderate true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak zinc grade.
Evidence · table
“0.5”
Context: 2.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.6
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · goldGrade: 0Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 0.8 m
- From
- 381.5 m
- To
- 382.6 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:381.5-382.6
- Mining Method
- underground
Location
- Location
- Footwall Vein (No. 1?)
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 9.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A barren gold grade over a narrow true width, indicating localized absence of gold mineralization.
Positive factors
- True width estimated.
Negative factors
- Barren gold grade.
Evidence · table
“0.0”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · silverGrade: 641Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 641
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 0.8 m
- From
- 381.5 m
- To
- 382.6 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:381.5-382.6
- Mining Method
- underground
Location
- Location
- Footwall Vein (No. 1?)
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 659
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver grade over a narrow true width, potentially identifying a new high-grade vein.
Positive factors
- Exceptional silver grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
- Identified a potential new vein (No. 1 Vein).
Negative factors
- Narrow intercept length.
Evidence · table
“641”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · copperGrade: 0Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 1.1 m
- True Width
- 0.8 m
- From
- 381.5 m
- To
- 382.6 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:381.5-382.6
- Mining Method
- underground
Location
- Location
- Footwall Vein (No. 1?)
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 9.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A barren copper grade over a narrow true width, indicating localized absence of copper mineralization.
Positive factors
- True width estimated.
Negative factors
- Barren copper grade.
Evidence · table
“0.0”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · leadGrade: 0.1Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 1.1 m
- True Width
- 0.8 m
- From
- 381.5 m
- To
- 382.6 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:381.5-382.6
- Mining Method
- underground
Location
- Location
- Footwall Vein (No. 1?)
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 9.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A very low lead grade over a narrow true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Very low lead grade.
Evidence · table
“0.1”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-153Silver Queen Au-Ag · zincGrade: 0.3Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-153
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.1 m
- True Width
- 0.8 m
- From
- 381.5 m
- To
- 382.6 m
- Hole Depth
- 399 m
- Intercept Depth
- 200.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-153:381.5-382.6
- Mining Method
- underground
Location
- Location
- Footwall Vein (No. 1?)
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 218 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 9.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak zinc grade over a narrow true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak zinc grade.
Evidence · table
“0.3”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.8
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-154Silver Queen Au-Ag · goldGrade: 0.6Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-154
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.6
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.3 m
- From
- 257.4 m
- To
- 257.9 m
- Hole Depth
- 300 m
- Intercept Depth
- 257.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-154:257.4-257.9
- Mining Method
- underground
Location
- Location
- No 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 235 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A low gold grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Low gold grade for an epithermal deposit.
- Very narrow intercept length.
Evidence · table
“0.6”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-154Silver Queen Au-Ag · silverGrade: 91Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-154
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 91
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.3 m
- From
- 257.4 m
- To
- 257.9 m
- Hole Depth
- 300 m
- Intercept Depth
- 257.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-154:257.4-257.9
- Mining Method
- underground
Location
- Location
- No 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 235 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 733
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver equivalent grade over a very narrow true width, contributing to the high-grade nature of the vein extension.
Positive factors
- Exceptional silver equivalent grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“91”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-154Silver Queen Au-Ag · copperGrade: 0.2Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-154
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.3 m
- From
- 257.4 m
- To
- 257.9 m
- Hole Depth
- 300 m
- Intercept Depth
- 257.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-154:257.4-257.9
- Mining Method
- underground
Location
- Location
- No 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 235 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak copper grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak copper grade for an epithermal deposit.
- Very narrow intercept length.
Evidence · table
“0.2”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-154Silver Queen Au-Ag · leadGrade: 5.2Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-154
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 5.2
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.3 m
- From
- 257.4 m
- To
- 257.9 m
- Hole Depth
- 300 m
- Intercept Depth
- 257.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-154:257.4-257.9
- Mining Method
- underground
Location
- Location
- No 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 235 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong lead grade over a very narrow true width, contributing to the polymetallic mineralization.
Positive factors
- Strong lead grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“5.2”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-154Silver Queen Au-Ag · zincGrade: 14.2Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-154
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 14.2
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.3 m
- From
- 257.4 m
- To
- 257.9 m
- Hole Depth
- 300 m
- Intercept Depth
- 257.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-154:257.4-257.9
- Mining Method
- underground
Location
- Location
- No 3 Vein
- Easting
- 648543
- Northing
- 5995946
- Elevation
- 952 m
- Azimuth
- 235 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.1
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong zinc grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Strong zinc grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“14.2”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · goldGrade: 1.7Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.7
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 135.3 m
- To
- 135.7 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:135.3-135.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.8
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold grade over a very narrow true width, contributing to the overall high-grade nature of the vein extension.
Positive factors
- Good gold grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“1.7”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · silverGrade: 179Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 179
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 135.3 m
- To
- 135.7 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:135.3-135.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 638
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver equivalent grade over a very narrow true width, significantly contributing to the high-grade nature of the vein extension.
Positive factors
- Exceptional silver equivalent grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“179”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · copperGrade: 1.9Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.9
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 135.3 m
- To
- 135.7 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:135.3-135.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.8
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong copper grade over a very narrow true width, adding to the polymetallic nature of the mineralization.
Positive factors
- Strong copper grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“1.9”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · leadGrade: 2.8Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.8
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 135.3 m
- To
- 135.7 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:135.3-135.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.8
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate lead grade over a very narrow true width, contributing to the polymetallic mineralization.
Positive factors
- Moderate lead grade.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“2.8”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · zincGrade: 2.6Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.6
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 135.3 m
- To
- 135.7 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:135.3-135.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.8
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate zinc grade over a very narrow true width, contributing to the polymetallic mineralization.
Positive factors
- Moderate zinc grade.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“2.6”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · goldGrade: 1.3Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.3
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 221.6 m
- To
- 222 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:221.6-222
- Mining Method
- underground
Location
- Location
- No. 2 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 13.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold grade over a very narrow true width, contributing to the overall high-grade nature of the vein extension.
Positive factors
- Good gold grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“1.3”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · silverGrade: 111Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 111
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 221.6 m
- To
- 222 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:221.6-222
- Mining Method
- underground
Location
- Location
- No. 2 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 993
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver equivalent grade over a very narrow true width, significantly contributing to the high-grade nature of the vein extension.
Positive factors
- Exceptional silver equivalent grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“111”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · copperGrade: 0.1Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 221.6 m
- To
- 222 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:221.6-222
- Mining Method
- underground
Location
- Location
- No. 2 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 13.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak copper grade over a very narrow true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak copper grade.
Evidence · table
“0.1”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · leadGrade: 8.5Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 8.5
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 221.6 m
- To
- 222 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:221.6-222
- Mining Method
- underground
Location
- Location
- No. 2 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 13.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong lead grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Strong lead grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“8.5”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-156Silver Queen Au-Ag · zincGrade: 18.2Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-156
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 18.2
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 221.6 m
- To
- 222 m
- Hole Depth
- 282 m
- Intercept Depth
- 135.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-156:221.6-222
- Mining Method
- underground
Location
- Location
- No. 2 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 210 °
- Dip
- -68 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 13.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional zinc grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Exceptional zinc grade for an epithermal deposit (above 18% threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“18.2”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · goldGrade: 1.2Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.2
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.5 m
- From
- 120.7 m
- To
- 123.7 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:120.7-123.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.6
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold grade over a moderate true width, contributing to the overall high-grade nature of the vein extension.
Positive factors
- Good gold grade for an epithermal deposit.
- True width estimated.
Evidence · table
“1.2”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · silverGrade: 79Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 79
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.5 m
- From
- 120.7 m
- To
- 123.7 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:120.7-123.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 478
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate silver grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- Moderate silver grade for an epithermal deposit.
- True width estimated.
Evidence · table
“79”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · copperGrade: 0.3Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 3 m
- True Width
- 2.5 m
- From
- 120.7 m
- To
- 123.7 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:120.7-123.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.6
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak copper grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak copper grade for an epithermal deposit.
Evidence · table
“0.3”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · leadGrade: 2.5Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.5
- Grade Unit
- %
- Intercept
- 3 m
- True Width
- 2.5 m
- From
- 120.7 m
- To
- 123.7 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:120.7-123.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.6
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate lead grade over a moderate true width, contributing to the polymetallic mineralization.
Positive factors
- Moderate lead grade.
- True width estimated.
Evidence · table
“2.5”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · zincGrade: 7Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 7
- Grade Unit
- %
- Intercept
- 3 m
- True Width
- 2.5 m
- From
- 120.7 m
- To
- 123.7 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:120.7-123.7
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.6
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong zinc grade over a moderate true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Strong zinc grade for an epithermal deposit.
- True width estimated.
Evidence · table
“7.0”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.5
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · goldGrade: 0.8Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 121.1 m
- To
- 121.5 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:121.1-121.5
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 20
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold equivalent grade over a very narrow true width, contributing to the overall high-grade nature of the vein extension.
Positive factors
- Good gold equivalent grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“0.8”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · silverGrade: 295Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 295
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 121.1 m
- To
- 121.5 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:121.1-121.5
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1448
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver equivalent grade over a very narrow true width, representing a bonanza intercept and significantly contributing to the high-grade nature of the vein extension.
Positive factors
- Exceptional silver equivalent grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“295”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · copperGrade: 0.7Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 121.1 m
- To
- 121.5 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:121.1-121.5
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 20
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak copper grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak copper grade for an epithermal deposit.
- Very narrow intercept length.
Evidence · table
“0.7”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · leadGrade: 10.7Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 10.7
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 121.1 m
- To
- 121.5 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:121.1-121.5
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 20
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional lead grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Exceptional lead grade for an epithermal deposit (above 10% threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“10.7”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · zincGrade: 24.2Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 24.2
- Grade Unit
- %
- Intercept
- 0.4 m
- True Width
- 0.3 m
- From
- 121.1 m
- To
- 121.5 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:121.1-121.5
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 20
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional zinc grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Exceptional zinc grade for an epithermal deposit (above 18% threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“24.2”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · goldGrade: 0.5Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.5
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.1 m
- From
- 180 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak gold grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak gold grade for an epithermal deposit.
Evidence · table
“0.5”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · silverGrade: 49Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 49
- Grade Unit
- g/t
- Intercept
- 1.3 m
- True Width
- 1.1 m
- From
- 180 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 248
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak silver grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak silver grade for an epithermal deposit.
Evidence · table
“49”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · copperGrade: 0Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 1.3 m
- True Width
- 1.1 m
- From
- 180 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A barren copper grade over a narrow true width, indicating localized absence of copper mineralization.
Positive factors
- True width estimated.
Negative factors
- Barren copper grade.
Evidence · table
“0.0”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · leadGrade: 1.5Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.5
- Grade Unit
- %
- Intercept
- 1.3 m
- True Width
- 1.1 m
- From
- 180 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak lead grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak lead grade.
Evidence · table
“1.5”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · zincGrade: 3.9Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 3.9
- Grade Unit
- %
- Intercept
- 1.3 m
- True Width
- 1.1 m
- From
- 180 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.4
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate zinc grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- Moderate zinc grade.
- True width estimated.
Evidence · table
“3.9”
Context: 1.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · goldGrade: 0.8Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.4 m
- From
- 180.8 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180.8-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A low gold grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Low gold grade for an epithermal deposit.
- Very narrow intercept length.
Evidence · table
“0.8”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · silverGrade: 88Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 88
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.4 m
- From
- 180.8 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180.8-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 486
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate silver grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- Moderate silver grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“88”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · copperGrade: 0.1Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.4 m
- From
- 180.8 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180.8-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak copper grade over a very narrow true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak copper grade.
Evidence · table
“0.1”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · leadGrade: 2.8Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.8
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.4 m
- From
- 180.8 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180.8-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate lead grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- Moderate lead grade.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“2.8”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-157Silver Queen Au-Ag · zincGrade: 8.3Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SQ25-157
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 8.3
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.4 m
- From
- 180.8 m
- To
- 181.3 m
- Hole Depth
- 192 m
- Intercept Depth
- 120.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-157:180.8-181.3
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 244 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.7
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong zinc grade over a very narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- Strong zinc grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“8.3”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · goldGrade: 0.2Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 6.1 m
- True Width
- 4.7 m
- From
- 218 m
- To
- 224.1 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-224.1
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.5
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak gold grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak gold grade for an epithermal deposit.
Evidence · table
“0.2”
Context: 6.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · silverGrade: 15Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 15
- Grade Unit
- g/t
- Intercept
- 6.1 m
- True Width
- 4.7 m
- From
- 218 m
- To
- 224.1 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-224.1
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 111
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak silver grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak silver grade for an epithermal deposit.
Evidence · table
“15”
Context: 6.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · copperGrade: 0Grade Unit: %Intercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 6.1 m
- True Width
- 4.7 m
- From
- 218 m
- To
- 224.1 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-224.1
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.5
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A barren copper grade over a moderate true width, indicating localized absence of copper mineralization.
Positive factors
- True width estimated.
Negative factors
- Barren copper grade.
Evidence · table
“0.0”
Context: 6.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · leadGrade: 0.3Grade Unit: %Intercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 6.1 m
- True Width
- 4.7 m
- From
- 218 m
- To
- 224.1 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-224.1
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.5
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak lead grade over a moderate true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak lead grade.
Evidence · table
“0.3”
Context: 6.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · zincGrade: 2.2Grade Unit: %Intercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.2
- Grade Unit
- %
- Intercept
- 6.1 m
- True Width
- 4.7 m
- From
- 218 m
- To
- 224.1 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-224.1
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.5
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak zinc grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak zinc grade.
Evidence · table
“2.2”
Context: 6.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.7
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · goldGrade: 0.3Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.3 m
- From
- 218 m
- To
- 221 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-221
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak gold grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak gold grade for an epithermal deposit.
Evidence · table
“0.3”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · silverGrade: 22Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 22
- Grade Unit
- g/t
- Intercept
- 3 m
- True Width
- 2.3 m
- From
- 218 m
- To
- 221 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-221
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 162
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak silver grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak silver grade for an epithermal deposit.
Evidence · table
“22”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · copperGrade: 0Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 3 m
- True Width
- 2.3 m
- From
- 218 m
- To
- 221 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-221
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A barren copper grade over a moderate true width, indicating localized absence of copper mineralization.
Positive factors
- True width estimated.
Negative factors
- Barren copper grade.
Evidence · table
“0.0”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · leadGrade: 0.5Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 3 m
- True Width
- 2.3 m
- From
- 218 m
- To
- 221 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-221
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak lead grade over a moderate true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak lead grade.
Evidence · table
“0.5”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-158Silver Queen Au-Ag · zincGrade: 3.2Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- SQ25-158
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 3.2
- Grade Unit
- %
- Intercept
- 3 m
- True Width
- 2.3 m
- From
- 218 m
- To
- 221 m
- Hole Depth
- 264 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-158:218-221
- Mining Method
- underground
Location
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 147 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.2
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A moderate zinc grade over a moderate true width, contributing to the overall polymetallic mineralization.
Positive factors
- Moderate zinc grade.
- True width estimated.
Evidence · table
“3.2”
Context: 3.0
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · goldGrade: 1.3Grade Unit: g/tIntercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.3
- Grade Unit
- g/t
- Intercept
- 2.3 m
- True Width
- 1.3 m
- From
- 197.6 m
- To
- 199.9 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-199.9
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 11
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold equivalent grade over a narrow true width, contributing to the overall high-grade nature of the vein extension.
Positive factors
- Good gold equivalent grade for an epithermal deposit.
- True width estimated.
Evidence · table
“1.3”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · silverGrade: 229Grade Unit: g/tIntercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 229
- Grade Unit
- g/t
- Intercept
- 2.3 m
- True Width
- 1.3 m
- From
- 197.6 m
- To
- 199.9 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-199.9
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 800
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver equivalent grade over a narrow true width, significantly contributing to the high-grade nature of the vein extension.
Positive factors
- Exceptional silver equivalent grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Evidence · table
“229”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · copperGrade: 1.6Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.6
- Grade Unit
- %
- Intercept
- 2.3 m
- True Width
- 1.3 m
- From
- 197.6 m
- To
- 199.9 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-199.9
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 11
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong copper grade over a narrow true width, adding to the polymetallic nature of the mineralization.
Positive factors
- Strong copper grade for an epithermal deposit.
- True width estimated.
Evidence · table
“1.6”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · leadGrade: 1Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1
- Grade Unit
- %
- Intercept
- 2.3 m
- True Width
- 1.3 m
- From
- 197.6 m
- To
- 199.9 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-199.9
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 11
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak lead grade over a narrow true width, contributing to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak lead grade.
Evidence · table
“1.0”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · zincGrade: 8.9Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 8.9
- Grade Unit
- %
- Intercept
- 2.3 m
- True Width
- 1.3 m
- From
- 197.6 m
- To
- 199.9 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-199.9
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 11
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong zinc grade over a narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Strong zinc grade for an epithermal deposit.
- True width estimated.
Evidence · table
“8.9”
Context: 2.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · goldGrade: 1.9Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.9
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.3 m
- From
- 197.6 m
- To
- 198.1 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-198.1
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A good gold equivalent grade over a very narrow true width, contributing to the overall high-grade nature of the vein extension.
Positive factors
- Good gold equivalent grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“1.9”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · silverGrade: 413Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 413
- Grade Unit
- g/t
- Intercept
- 0.6 m
- True Width
- 0.3 m
- From
- 197.6 m
- To
- 198.1 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-198.1
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1374
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional silver equivalent grade over a very narrow true width, representing a bonanza intercept and significantly contributing to the high-grade nature of the vein extension.
Positive factors
- Exceptional silver equivalent grade for an epithermal deposit (above 500 g/t threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“413”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · copperGrade: 3.1Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 3.1
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.3 m
- From
- 197.6 m
- To
- 198.1 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-198.1
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: An exceptional copper grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Exceptional copper grade for an epithermal deposit (above 2.5% threshold).
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“3.1”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · leadGrade: 0.4Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.3 m
- From
- 197.6 m
- To
- 198.1 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-198.1
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A weak lead grade over a very narrow true width, contributing minimally to the overall polymetallic mineralization.
Positive factors
- True width estimated.
Negative factors
- Weak lead grade.
Evidence · table
“0.4”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
SQ25-159Silver Queen Au-Ag · zincGrade: 15.1Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SQ25-159
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 15.1
- Grade Unit
- %
- Intercept
- 0.6 m
- True Width
- 0.3 m
- From
- 197.6 m
- To
- 198.1 m
- Hole Depth
- 213 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SQ25-159:197.6-198.1
- Mining Method
- underground
Location
- Location
- No. 3 Vein
- Easting
- 648550
- Northing
- 5995843
- Elevation
- 944 m
- Azimuth
- 140 °
- Dip
- -72 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t AuEq
- Assumptions Disclosed
- Yes
Compositing
- Cutoff Grade
- 80
- Cutoff Unit
- g/t AgEq
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: A strong zinc grade over a very narrow true width, significantly contributing to the polymetallic mineralization.
Positive factors
- Strong zinc grade for an epithermal deposit.
- True width estimated.
Negative factors
- Very narrow intercept length.
Evidence · table
“15.1”
Context: 0.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: cutoff_grade and internal dilution are both stated
andVein · goldGrade: 0.3Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 320 m
- To
- 322 m
- Intercept Depth
- 320 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:320-322
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 245
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.3 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.6 g/t·m is below.
Negative factors
- 0.3 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.3”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · silverGrade: 200Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 200
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 320 m
- To
- 322 m
- Intercept Depth
- 320 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:320-322
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 245
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 200 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 400.0 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 200 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“200”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · copperGrade: 0Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 2 m
- From
- 320 m
- To
- 322 m
- Intercept Depth
- 320 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:320-322
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 245
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.0”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · leadGrade: 0.1Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 2 m
- From
- 320 m
- To
- 322 m
- Intercept Depth
- 320 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:320-322
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 245
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.1 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.1”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · zincGrade: 0.5Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 2 m
- From
- 320 m
- To
- 322 m
- Intercept Depth
- 320 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:320-322
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 245
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.5 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.0 %·m is below.
Negative factors
- 0.5 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.5”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · goldGrade: 0Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 381.5 m
- To
- 382.6 m
- Intercept Depth
- 381.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:381.5-382.6
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 659
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.0”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · silverGrade: 641Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 641
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 381.5 m
- To
- 382.6 m
- Intercept Depth
- 381.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:381.5-382.6
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 659
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 641 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 705.1 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 641 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“641”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · copperGrade: 0Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 381.5 m
- To
- 382.6 m
- Intercept Depth
- 381.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:381.5-382.6
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 659
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.0”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · leadGrade: 0.1Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 381.5 m
- To
- 382.6 m
- Intercept Depth
- 381.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:381.5-382.6
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 659
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.1 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.1”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · zincGrade: 0.3Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 381.5 m
- To
- 382.6 m
- Intercept Depth
- 381.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:381.5-382.6
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 659
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.3 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.3 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.3”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · goldGrade: 1.3Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.3
- Grade Unit
- g/t
- Intercept
- 0.4 m
- From
- 221.6 m
- To
- 222 m
- Intercept Depth
- 221.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:221.6-222
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 993
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 1.3 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.5 g/t·m is below.
Negative factors
- 1.3 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.3”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · silverGrade: 111Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 111
- Grade Unit
- g/t
- Intercept
- 0.4 m
- From
- 221.6 m
- To
- 222 m
- Intercept Depth
- 221.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:221.6-222
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 993
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 111 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 44.4 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“111”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · copperGrade: 0.1Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 221.6 m
- To
- 222 m
- Intercept Depth
- 221.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:221.6-222
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 993
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.1 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.1”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · leadGrade: 8.5Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 8.5
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 221.6 m
- To
- 222 m
- Intercept Depth
- 221.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:221.6-222
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 993
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 8.5 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 3.4 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 8.5 % lead is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.5”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · zincGrade: 18.2Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 18.2
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 221.6 m
- To
- 222 m
- Intercept Depth
- 221.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:221.6-222
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 993
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 18.2 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 7.3 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 18.2 % zinc is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“18.2”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · goldGrade: 0.8Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 0.4 m
- From
- 121.1 m
- To
- 121.5 m
- Intercept Depth
- 121.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:121.1-121.5
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1448
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.8 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.8 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.8”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · silverGrade: 295Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 295
- Grade Unit
- g/t
- Intercept
- 0.4 m
- From
- 121.1 m
- To
- 121.5 m
- Intercept Depth
- 121.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:121.1-121.5
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1448
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 295 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 118.0 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 295 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“295”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · copperGrade: 0.7Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.7
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 121.1 m
- To
- 121.5 m
- Intercept Depth
- 121.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:121.1-121.5
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1448
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.7 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.3 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.7”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · leadGrade: 10.7Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 10.7
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 121.1 m
- To
- 121.5 m
- Intercept Depth
- 121.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:121.1-121.5
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1448
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 10.7 % lead is exceptional against the default band [10, 6, 3, 1] %. Grade×width 4.3 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 10.7 % lead is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.7”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · zincGrade: 24.2Grade Unit: %Intercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 24.2
- Grade Unit
- %
- Intercept
- 0.4 m
- From
- 121.1 m
- To
- 121.5 m
- Intercept Depth
- 121.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:121.1-121.5
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1448
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 24.2 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 9.7 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 24.2 % zinc is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“24.2”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · goldGrade: 0.5Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.5
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 180 m
- To
- 181.3 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:180-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 248
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.5 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 0.5 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.5”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · silverGrade: 49Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 49
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 180 m
- To
- 181.3 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:180-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 248
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 49 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 63.7 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“49”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · copperGrade: 0Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 1.3 m
- From
- 180 m
- To
- 181.3 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:180-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 248
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.0”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · leadGrade: 1.5Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.5
- Grade Unit
- %
- Intercept
- 1.3 m
- From
- 180 m
- To
- 181.3 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:180-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 248
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 1.5 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 2.0 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.5”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · zincGrade: 3.9Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 3.9
- Grade Unit
- %
- Intercept
- 1.3 m
- From
- 180 m
- To
- 181.3 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:180-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 248
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 3.9 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 5.1 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.9”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · goldGrade: 0.8Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.8
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 180.8 m
- To
- 181.3 m
- Intercept Depth
- 180.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:180.8-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 486
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.8 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.4 g/t·m is below.
Negative factors
- 0.8 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.8”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · silverGrade: 88Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 88
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 180.8 m
- To
- 181.3 m
- Intercept Depth
- 180.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:180.8-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 486
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 88 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 44.0 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“88”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · copperGrade: 0.1Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 180.8 m
- To
- 181.3 m
- Intercept Depth
- 180.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:180.8-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 486
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.1 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.1”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · leadGrade: 2.8Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.8
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 180.8 m
- To
- 181.3 m
- Intercept Depth
- 180.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:180.8-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 486
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 2.8 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.4 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.8”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · zincGrade: 8.3Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 8.3
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 180.8 m
- To
- 181.3 m
- Intercept Depth
- 180.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:180.8-181.3
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 486
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 8.3 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 4.2 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.3”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · goldGrade: 0.2Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 218 m
- To
- 224.1 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:218-224.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 111
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.2 g/t·m is below.
Negative factors
- 0.2 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.2”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · silverGrade: 15Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 15
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 218 m
- To
- 224.1 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:218-224.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 111
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 15 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 91.5 g/t·m is below.
Negative factors
- 15 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“15”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · copperGrade: 0Grade Unit: %Intercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 6.1 m
- From
- 218 m
- To
- 224.1 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:218-224.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 111
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.0”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · leadGrade: 0.3Grade Unit: %Intercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 6.1 m
- From
- 218 m
- To
- 224.1 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:218-224.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 111
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.3 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.8 %·m is below.
Negative factors
- 0.3 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.3”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andVein · zincGrade: 2.2Grade Unit: %Intercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Vein
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 2.2
- Grade Unit
- %
- Intercept
- 6.1 m
- From
- 218 m
- To
- 224.1 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- and:218-224.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 111
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 2.2 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 13.4 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.2”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · goldGrade: 0.3Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 218 m
- To
- 221 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:218-221
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 162
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.3 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.9 g/t·m is below.
Negative factors
- 0.3 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.3”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · silverGrade: 22Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 22
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 218 m
- To
- 221 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:218-221
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 162
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 22 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 66.0 g/t·m is below.
Negative factors
- 22 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“22”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · copperGrade: 0Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 3 m
- From
- 218 m
- To
- 221 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:218-221
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 162
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.0”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · leadGrade: 0.5Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 3 m
- From
- 218 m
- To
- 221 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:218-221
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 162
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.5 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.5 %·m is below.
Negative factors
- 0.5 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.5”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · zincGrade: 3.2Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 3.2
- Grade Unit
- %
- Intercept
- 3 m
- From
- 218 m
- To
- 221 m
- Intercept Depth
- 218 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:218-221
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 162
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 3.2 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 9.6 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.2”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · goldGrade: 1.9Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- gold
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 1.9
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 197.6 m
- To
- 198.1 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:197.6-198.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1374
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 1.9 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.1 g/t·m is below.
Negative factors
- 1.9 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.9”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · silverGrade: 413Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- silver
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 413
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 197.6 m
- To
- 198.1 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:197.6-198.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1374
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 413 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 247.8 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 413 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“413”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · copperGrade: 3.1Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- copper
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 3.1
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 197.6 m
- To
- 198.1 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:197.6-198.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1374
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 3.1 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.9 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 3.1 % copper is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.1”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · leadGrade: 0.4Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- lead
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 197.6 m
- To
- 198.1 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:197.6-198.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1374
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.4 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.4 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.4”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
inc.Silver Queen Au-Ag · zincGrade: 15.1Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- inc.
- Project
- Silver Queen Au-Ag
- Commodity
- zinc
- Region
- canada_bc
- Reported Region
- canada_bc
- Ticker
- EQTY
Geometry
- Grade
- 15.1
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 197.6 m
- To
- 198.1 m
- Intercept Depth
- 197.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- inc.:197.6-198.1
- Mining Method
- underground
QA/QC
- Laboratory
- MS Analytical
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1374
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-09-23T00:00:00.000Z
Reasoning: Expanded from assay table. 15.1 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 9.1 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 15.1 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“15.1”
Context: inc.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.