ESCONDIDA VEIN RETURNS FIRST DRILL INTERCEPT OF 4.25 g/t Au OVER 1.85 m, INCLUDING 12.10 g/t Au OVER 0.65 m
Original announcement by tmx on
- Company
- Soma Gold Corp.
- Ticker
- SOMA
- Exchange
- TSX
- Region
- Antioquia, Colombia
- Primary commodity
- Gold
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-09-18 22:21:10 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Soma Gold Corp. announced high-grade gold drill and channel sample results from its Escondida Project in Antioquia, Colombia. The first drill hole, EZDDH-26-001, returned 4.25 g/t Au over 1.85 m, including 12.10 g/t Au over 0.65 m, confirming near-mine continuity. Additionally, underground channel samples yielded bonanza grades up to 38.36 g/t Au, extending mineralization in previously flooded areas and highlighting the project's potential.
Reasoning: The announcement reports strong initial drill results and high-grade channel samples from the Escondida Project, confirming the continuity and tenor of gold mineralization. The disclosure of true width and a robust QA/QC program adds confidence to the results. The bonanza grades in several channel samples are particularly positive, suggesting significant potential for resource expansion in previously inaccessible areas. While one drill hole was lost, the overall program appears to be progressing well with follow-up drilling already underway.
Positive factors
- High-grade gold intercepts from both drill core and channel samples, including bonanza grades.
- First drill intercept on the Escondida Vein confirms continuity and tenor of mineralization.
- Channel sampling in previously flooded areas reveals high-grade zones, indicating potential for resource expansion.
- True width is disclosed for both drill and channel samples, enhancing confidence in reported widths.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Negative factors
- Drilling difficulties encountered in EZDDH-26-002 led to the loss of the hole, indicating potential ground conditions challenges.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 42
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The drill intercept in EZDDH-26-001 includes 12.10 g/t Au over 0.65 m, which is well above the exceptional threshold for gold in an underground setting (15 g/t Au) when considering the GT product, and several channel samples exceed 30 g/t Au.
Evidence · table
“12.10”
Context: 0.65
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The drill hole EZDDH-26-001 reports a true width of 1.55 m for the main intercept and 0.55 m for the included interval. For channel samples, it is stated that 'The stated width is approximately 95% to 100% of the true width.'
Evidence · table
“1.55”
Context: 1.85
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release includes a detailed QA/QC Statement mentioning Actlabs Colombia SAS and Actlabs Canada, regular insertion of certified blanks, duplicates, and certified OREAS standards, and QP sign-off by Chris Buchanan, P.Geo.
Evidence · text
“A comprehensive QA/QC program has been implemented to monitor the reliability of assay data collected during exploration programs. The program includes the regular insertion of certified blanks, duplicates, and certified OREAS standards.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: The channel sample results note that 'Intervals are composited to a 1 m minimum stope width for conventional mining.'
Evidence · table
“Note: Intervals are composited to a 1 m minimum stope width for conventional mining.”
Context: Note: Intervals are composited to a 1 m minimum stope width for conventional mining.
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: EZDDH-26-001 was targeted to intercept the Escondida Vein 25 m northeast of the current mine workings, indicating an extension of known mineralization.
Evidence · text
“EZDDH-26-001 was targeted to intercept the Escondida Vein 25 m northeast of the current mine workings at a depth of 100 m below surface or approximately level 10”
Extracted facts
Stored fact records: 42. Some facts used in scoring do not have a stored record.
Drill Results (42)
EZDDH-26-001Escondida · goldGrade: 4.25Grade Unit: g/tIntercept: 1.85 mView all detailsHide details
Identity
- Hole ID
- EZDDH-26-001
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 4.25
- Grade Unit
- g/t
- Intercept
- 1.85 m
- True Width
- 1.55 m
- From
- 169.8 m
- To
- 172 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- EZDDH-26-001:169.8-172
- Mining Method
- underground
Location
- Location
- Escondida Vein
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This is the first drill intercept reported for the Escondida Vein, confirming gold mineralization with a strong grade and disclosed true width. The program is exploratory, aiming to extend the known footprint, and the results are positive for this objective. QA/QC is well-documented.
Positive factors
- First drill intercept on the Escondida Vein confirms continuity and tenor of mineralization.
- True width is disclosed, enhancing confidence in reported width.
- High-grade gold intercept (4.25 g/t Au) is strong for an underground setting.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“4.25”
Context: 1.85
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.55
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
EZDDH-26-001Escondida · goldGrade: 12.1Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- EZDDH-26-001
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 12.1
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.55 m
- From
- 171 m
- To
- 172 m
- Intercept Depth
- 171 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- EZDDH-26-001:171-172
- Mining Method
- underground
Location
- Location
- Escondida Vein
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows bonanza-grade gold, significantly enhancing the overall intercept's value. The true width is provided, and the results are supported by a robust QA/QC program.
Positive factors
- Bonanza grade gold intercept (12.10 g/t Au) within the broader interval, indicating high-grade core.
- True width is disclosed, enhancing confidence in reported width.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“12.10”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.55
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU201021Escondida · goldGrade: 0.45Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- CHU201021
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU201021:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.45”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU201022Escondida · goldGrade: 3.09Grade Unit: g/tIntercept: 1.1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- CHU201022
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 3.09
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 1.045 m
- From
- 0 m
- To
- 1.1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU201022:0-1.1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a strong gold grade, contributing positively to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- Strong gold grade (3.09 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“3.09”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.045
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU201022Escondida · goldGrade: 5.85Grade Unit: g/tIntercept: 0.5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- CHU201022
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 5.85
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.475 m
- From
- 0 m
- To
- 0.5 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU201022:0-0.5
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a high-grade gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (5.85 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“5.85”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.475
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU201022Escondida · goldGrade: 0.02Grade Unit: g/tIntercept: 1.2 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- CHU201022
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 1.2 m
- True Width
- 1.14 m
- From
- 1.1 m
- To
- 2.3 m
- Intercept Depth
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU201022:1.1-2.3
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, indicating areas of minimal mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.02”
Context: 1.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.14
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500167Escondida · goldGrade: 2.27Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500167
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 2.27
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500167:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a moderate gold grade, contributing positively to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- Moderate gold grade (2.27 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“2.27”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500167Escondida · goldGrade: 6.48Grade Unit: g/tIntercept: 0.35 mView all detailsHide details
Identity
- Hole ID
- CHU500167
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 6.48
- Grade Unit
- g/t
- Intercept
- 0.35 m
- True Width
- 0.3325 m
- From
- 0 m
- To
- 0.35 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500167:0-0.35
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a high-grade gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (6.48 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“6.48”
Context: 0.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.3325
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500168Escondida · goldGrade: 0.09Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500168
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500168:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.09”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500170Escondida · goldGrade: 0.13Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500170
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500170:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.13”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500171Escondida · goldGrade: 0.02Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500171
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500171:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.02”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500172Escondida · goldGrade: 0.03Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500172
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0.25 m
- To
- 1.25 m
- Intercept Depth
- 0.25 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500172:0.25-1.25
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.03”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500173Escondida · goldGrade: 0.22Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500173
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500173:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.22”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500174Escondida · goldGrade: 0.73Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500174
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.73
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500174:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a low-moderate gold intercept, contributing to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.73”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500174Escondida · goldGrade: 4.1Grade Unit: g/tIntercept: 0.15 mView all detailsHide details
Identity
- Hole ID
- CHU500174
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 4.1
- Grade Unit
- g/t
- Intercept
- 0.15 m
- True Width
- 0.1425 m
- From
- 0.3 m
- To
- 0.45 m
- Intercept Depth
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500174:0.3-0.45
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a strong gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- Strong gold grade (4.1 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“4.1”
Context: 0.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.1425
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500175Escondida · goldGrade: 0.17Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500175
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.17
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500175:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.17”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500176Escondida · goldGrade: 0.03Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- CHU500176
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 1.1 m
- True Width
- 1.045 m
- From
- 0 m
- To
- 1.1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500176:0-1.1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.03”
Context: 1.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.045
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500177Escondida · goldGrade: 0.03Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500177
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500177:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.03”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500178Escondida · goldGrade: 0.21Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500178
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500178:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.21”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500179Escondida · goldGrade: 0.01Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500179
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 1.25 m
- To
- 2.25 m
- Intercept Depth
- 1.25 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500179:1.25-2.25
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.01”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500180Escondida · goldGrade: 0Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500180
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0.55 m
- To
- 1.55 m
- Intercept Depth
- 0.55 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500180:0.55-1.55
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a barren gold intercept, indicating areas of no mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500181Escondida · goldGrade: 0Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500181
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500181:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a barren gold intercept, indicating areas of no mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU500182Escondida · goldGrade: 0.01Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU500182
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU500182:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.01”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600000Escondida · goldGrade: 0.36Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600000
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600000:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.36”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600001Escondida · goldGrade: 0.07Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600001
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600001:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.07”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600002Escondida · goldGrade: 0.05Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600002
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600002:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.05”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600003Escondida · goldGrade: 0.04Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600003
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600003:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.04”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600004Escondida · goldGrade: 2.53Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600004
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 2.53
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600004:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a moderate gold grade, contributing positively to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- Moderate gold grade (2.53 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“2.53”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600004Escondida · goldGrade: 10.03Grade Unit: g/tIntercept: 0.25 mView all detailsHide details
Identity
- Hole ID
- CHU600004
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 10.03
- Grade Unit
- g/t
- Intercept
- 0.25 m
- True Width
- 0.2375 m
- From
- 0 m
- To
- 0.25 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600004:0-0.25
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a high-grade gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (10.03 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“10.03”
Context: 0.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.2375
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600005Escondida · goldGrade: 15.4Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600005
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 15.4
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600005:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a high-grade gold intercept, contributing significantly to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (15.4 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“15.4”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600005Escondida · goldGrade: 38.22Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- CHU600005
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 38.22
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.38 m
- From
- 0.3 m
- To
- 0.7 m
- Intercept Depth
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600005:0.3-0.7
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a bonanza-grade gold intercept, significantly enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- Bonanza grade gold intercept (38.22 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“38.22”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.38
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600006Escondida · goldGrade: 16.61Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600006
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 16.61
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600006:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a high-grade gold intercept, contributing significantly to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (16.61 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“16.61”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600006Escondida · goldGrade: 36.72Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- CHU600006
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 36.72
- Grade Unit
- g/t
- Intercept
- 0.45 m
- True Width
- 0.4275 m
- From
- 0.3 m
- To
- 0.75 m
- Intercept Depth
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600006:0.3-0.75
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a bonanza-grade gold intercept, significantly enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- Bonanza grade gold intercept (36.72 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“36.72”
Context: 0.45
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.4275
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600007Escondida · goldGrade: 2.52Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600007
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 2.52
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600007:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a moderate gold grade, contributing positively to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- Moderate gold grade (2.52 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“2.52”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600007Escondida · goldGrade: 4.47Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHU600007
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 4.47
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.475 m
- From
- 0.3 m
- To
- 0.8 m
- Intercept Depth
- 0.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600007:0.3-0.8
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a strong gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- Strong gold grade (4.47 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“4.47”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.475
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600008Escondida · goldGrade: 19.24Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600008
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 19.24
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600008:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a high-grade gold intercept, contributing significantly to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (19.24 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“19.24”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600008Escondida · goldGrade: 38.36Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHU600008
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 38.36
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.475 m
- From
- 0.35 m
- To
- 0.85 m
- Intercept Depth
- 0.35 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600008:0.35-0.85
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a bonanza-grade gold intercept, significantly enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- Bonanza grade gold intercept (38.36 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“38.36”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.475
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600023Escondida · goldGrade: 3.93Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- CHU600023
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 3.93
- Grade Unit
- g/t
- Intercept
- 1.25 m
- True Width
- 1.1875 m
- From
- 0 m
- To
- 1.25 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600023:0-1.25
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a strong gold grade, contributing positively to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- Strong gold grade (3.93 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“3.93”
Context: 1.25
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.1875
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600023Escondida · goldGrade: 11.7Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- CHU600023
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 11.7
- Grade Unit
- g/t
- Intercept
- 0.4 m
- True Width
- 0.38 m
- From
- 0.85 m
- To
- 1.25 m
- Intercept Depth
- 0.85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600023:0.85-1.25
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a high-grade gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- High-grade gold intercept (11.7 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“11.7”
Context: 0.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.38
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600023-2Escondida · goldGrade: 0.17Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600023-2
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 0.17
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0 m
- To
- 1 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600023-2:0-1
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a very low-grade gold intercept, but contributes to the overall understanding of mineralization in the area. True width is disclosed and QA/QC is robust.
Positive factors
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“0.17”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600024Escondida · goldGrade: 2.1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- CHU600024
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 2.1
- Grade Unit
- g/t
- Intercept
- 1 m
- True Width
- 0.95 m
- From
- 0.6 m
- To
- 1.6 m
- Intercept Depth
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600024:0.6-1.6
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This channel sample shows a moderate gold grade, contributing positively to the understanding of mineralization. True width is disclosed and QA/QC is robust.
Positive factors
- Moderate gold grade (2.1 g/t Au) for an underground channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“2.1”
Context: 1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.95
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
CHU600024Escondida · goldGrade: 4.2Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- CHU600024
- Project
- Escondida
- Commodity
- gold
- Region
- colombia
- Reported Region
- colombia
- Ticker
- SOMA
Geometry
- Grade
- 4.2
- Grade Unit
- g/t
- Intercept
- 0.5 m
- True Width
- 0.475 m
- From
- 1.1 m
- To
- 1.6 m
- Intercept Depth
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Group ID
- CHU600024:1.1-1.6
- Mining Method
- underground
QA/QC
- Laboratory
- Actlabs Medellín and Actlabs Canada
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Max Dilution
- 1 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-08-18T00:00:00.000Z
Reasoning: This included interval shows a strong gold intercept, further enhancing the positive results from the channel sample. True width is disclosed and QA/QC is robust.
Positive factors
- Strong gold grade (4.2 g/t Au) within the broader channel sample.
- True width is disclosed for channel samples.
- Comprehensive QA/QC program is disclosed, including certified labs, standards, blanks, and duplicates, and QP sign-off.
Evidence · table
“4.2”
Context: 0.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.475
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The operator mined 200 m of strike length to a vertical depth of 105 m, developing the mine on 5 m levels, most of which"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.