F3 - Hits 2.5m of 10.2% U3O8 Within 3.4% over 8.5m at JR Zone
Original announcement by tmx on
- Company
- F3 Uranium Corp.
- Ticker
- FUU
- Exchange
- TSX
- Region
- Saskatchewan
- Primary commodity
- Uranium
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-09-17 23:02:53 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
F3 Uranium Corp. announced final assay results from its 2025 drill program at the PLN Property, highlighting high-grade uranium intercepts. Hole PLN25-200 at the JR Zone returned 8.5m of 3.4% U3O8, including 2.5m of 10.2% U3O8 and 1.0m of 20.7% U3O8. At the Tetra Zone, PLN25-217 confirmed high-grade mineralization 55m along strike from a discovery hole, with a 0.5m interval of 1.04% U3O8 within a wider 3.5m zone averaging 0.30% U3O8. These results will be incorporated into an upcoming maiden resource estimate for the JR Zone.
Reasoning: The announcement reports significant high-grade and ultra-high-grade uranium intercepts from the JR Zone and Tetra Zone, confirming mineralization continuity and potential for resource growth. The results are supported by robust QA/QC and contribute to an upcoming maiden resource estimate.
Positive factors
- High-grade uranium intercepts in PLN25-200 and PLN25-217, including ultra-high grade sections.
- Confirmation of additional high-grade mineralization 55m along strike at Tetra Zone, indicating potential for extension.
- Comprehensive QA/QC disclosure with accredited lab and QP sign-off.
- Upcoming maiden resource estimate for JR Zone.
Negative factors
- True thicknesses are yet to be determined for all reported intercepts.
- Some holes reported no mineralization above the cut-off, indicating variability.
Facts used in scoring: 35
Extracted facts
Stored fact records: 35. Some facts used in scoring do not have a stored record.
Drill Results (35)
PLN25-197Patterson Lake North · uraniumGrade: 1.08Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-197
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 1.08
- Grade Unit
- %
- Intercept
- 1.5 m
- From
- 207 m
- To
- 208.5 m
- Intercept Depth
- 207 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-197:207-208.5
Location
- Easting
- 587776
- Northing
- 6410760
- Elevation
- 546 m
- Azimuth
- 55 °
- Dip
- -71 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a strong uranium grade, contributing positively to the project's prospectivity.
Positive factors
- High-grade uranium intercept (1.08% U3O8 exceeds 0.5% strong threshold for uranium).
Negative factors
- True thickness not determined.
Evidence · table
“1.08”
Context: 1.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-197Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-197
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 211 m
- To
- 211.5 m
- Intercept Depth
- 211 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-197:211-211.5
Location
- Easting
- 587776
- Northing
- 6410760
- Elevation
- 546 m
- Azimuth
- 55 °
- Dip
- -71 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.07”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-198Patterson Lake North · uraniumGrade: 0.26Grade Unit: %Intercept: 7.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-198
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 7.5 m
- From
- 215.5 m
- To
- 223 m
- Intercept Depth
- 215.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-198:215.5-223
Location
- Easting
- 587843
- Northing
- 6410645
- Elevation
- 546 m
- Azimuth
- 9 °
- Dip
- -65 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization.
Positive factors
- Moderate width intercept (7.5m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.26”
Context: 7.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-198Patterson Lake North · uraniumGrade: 1.33Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-198
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 1.33
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 220.5 m
- To
- 221 m
- Intercept Depth
- 220.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-198:220.5-221
Location
- Easting
- 587843
- Northing
- 6410645
- Elevation
- 546 m
- Azimuth
- 9 °
- Dip
- -65 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This narrow intercept shows a strong uranium grade, indicating a high-grade core within a wider zone.
Positive factors
- High-grade uranium intercept (1.33% U3O8 exceeds 0.5% strong threshold for uranium).
Negative factors
- Narrow intercept length (0.5m).
- True thickness not determined.
Evidence · table
“1.33”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-199Patterson Lake North · uraniumGrade: 0.29Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-199
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 1.5 m
- From
- 242 m
- To
- 243.5 m
- Intercept Depth
- 242 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-199:242-243.5
Location
- Easting
- 587693
- Northing
- 6410748
- Elevation
- 545 m
- Azimuth
- 55 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.29”
Context: 1.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 0.27Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PLN25-200
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 2 m
- From
- 234 m
- To
- 236 m
- Intercept Depth
- 234 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-200:234-236
Location
- Location
- JR Zone
- Easting
- 587731
- Northing
- 6410712
- Elevation
- 545 m
- Azimuth
- 53 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization in the JR Zone.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.27”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 10.2Grade Unit: %Intercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-200
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 10.2
- Grade Unit
- %
- Intercept
- 2.5 m
- From
- 236 m
- To
- 238.5 m
- Intercept Depth
- 236 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-200:236-238.5
Location
- Location
- JR Zone
- Easting
- 587731
- Northing
- 6410712
- Elevation
- 545 m
- Azimuth
- 53 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept represents an exceptional high-grade uranium zone, significantly enhancing the project's value and contributing to the upcoming resource estimate.
Positive factors
- Bonanza grade uranium intercept (10.2% U3O8 exceeds 2% exceptional threshold for uranium).
- Significant grade-width product (25.5 %·m).
Negative factors
- True thickness not determined.
Evidence · table
“10.2”
Context: 2.50
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Exceptionally high-grade zone, well above the deposit-type norm (10.2% U3O8 exceeds 2% exceptional threshold).
Evidence · table
“10.2”
Context: 2.50
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 20.7Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- PLN25-200
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 20.7
- Grade Unit
- %
- Intercept
- 1 m
- From
- 237.5 m
- To
- 238.5 m
- Intercept Depth
- 237.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-200:237.5-238.5
Location
- Location
- JR Zone
- Easting
- 587731
- Northing
- 6410712
- Elevation
- 545 m
- Azimuth
- 53 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept represents an ultra-high-grade uranium zone, significantly enhancing the project's value and contributing to the upcoming resource estimate.
Positive factors
- Bonanza grade uranium intercept (20.7% U3O8 exceeds 2% exceptional threshold for uranium, and company defines >20% as ultra-high grade).
- Significant grade-width product (20.7 %·m).
Negative factors
- True thickness not determined.
Evidence · table
“20.7”
Context: 1.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Exceptionally high-grade zone, well above the deposit-type norm (20.7% U3O8 exceeds 2% exceptional threshold and company defines >20% as ultra-high grade).
Evidence · table
“20.7”
Context: 1.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 0.76Grade Unit: %Intercept: 4 mView all detailsHide details
Identity
- Hole ID
- PLN25-200
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.76
- Grade Unit
- %
- Intercept
- 4 m
- From
- 238.5 m
- To
- 242.5 m
- Intercept Depth
- 238.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-200:238.5-242.5
Location
- Location
- JR Zone
- Easting
- 587731
- Northing
- 6410712
- Elevation
- 545 m
- Azimuth
- 53 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a strong uranium grade over a moderate width, contributing to the overall mineralization in the JR Zone.
Positive factors
- Strong uranium grade (0.76% U3O8 exceeds 0.5% strong threshold for uranium).
Negative factors
- True thickness not determined.
Evidence · table
“0.76”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 0.05Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-200
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 246.5 m
- To
- 252 m
- Intercept Depth
- 246.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-200:246.5-252
Location
- Location
- JR Zone
- Easting
- 587731
- Northing
- 6410712
- Elevation
- 545 m
- Azimuth
- 53 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is at the cut-off grade, indicating marginal mineralization.
Negative factors
- Low-grade uranium intercept, at cut-off.
- True thickness not determined.
Evidence · table
“0.05”
Context: 5.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 3.4Grade Unit: %Intercept: 8.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-200
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 3.4
- Grade Unit
- %
- Intercept
- 8.5 m
- From
- 234 m
- To
- 242.5 m
- Intercept Depth
- 234 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-200:234-242.5
Location
- Location
- JR Zone
- Easting
- 587731
- Northing
- 6410712
- Elevation
- 545 m
- Azimuth
- 53 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This composite interval represents a significant high-grade uranium intercept, contributing strongly to the project's potential and upcoming resource estimate.
Positive factors
- Exceptional uranium grade (3.4% U3O8 exceeds 2% exceptional threshold for uranium).
- Strong width intercept (8.5m).
- Significant grade-width product (28.9 %·m).
Negative factors
- True thickness not determined.
Evidence · text
“8.5m of 3.4% U3O8”
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: Exceptionally high-grade zone, well above the deposit-type norm (3.4% U3O8 exceeds 2% exceptional threshold).
Evidence · text
“8.5m of 3.4% U3O8”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-207Patterson Lake North · uraniumGrade: 0.06Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-207
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 621 m
- To
- 621.5 m
- Intercept Depth
- 621 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-207:621-621.5
Location
- Location
- Tetra Zone
- Easting
- 589481
- Northing
- 6397809
- Elevation
- 587 m
- Azimuth
- 46 °
- Dip
- -66 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept, while low-grade, is significant for indicating mineralization at depth and extending the known shear system.
Positive factors
- Indicates mineralization at depth, associated with the Tetra Zone shear system.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.06”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake NorthView all detailsHide details
Identity
- Hole ID
- PLN25-210
- Project
- Patterson Lake North
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Classification
- Sample Type
- drill
Location
- Easting
- 589341
- Northing
- 6397997
- Elevation
- 583 m
- Azimuth
- 47 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.18”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.13Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-210
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 364 m
- To
- 364.5 m
- Intercept Depth
- 364 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-210:364-364.5
Location
- Easting
- 589341
- Northing
- 6397997
- Elevation
- 583 m
- Azimuth
- 47 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.13”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.06Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-210
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 369.5 m
- To
- 370 m
- Intercept Depth
- 369.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-210:369.5-370
Location
- Easting
- 589341
- Northing
- 6397997
- Elevation
- 583 m
- Azimuth
- 47 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.06”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.08Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-210
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 382.5 m
- To
- 383 m
- Intercept Depth
- 382.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-210:382.5-383
Location
- Easting
- 589341
- Northing
- 6397997
- Elevation
- 583 m
- Azimuth
- 47 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.08”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.14Grade Unit: %Intercept: 6 mView all detailsHide details
Identity
- Hole ID
- PLN25-210
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 6 m
- From
- 388.5 m
- To
- 394.5 m
- Intercept Depth
- 388.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-210:388.5-394.5
Location
- Easting
- 589341
- Northing
- 6397997
- Elevation
- 583 m
- Azimuth
- 47 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization.
Positive factors
- Moderate width intercept (6.0m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.14”
Context: 6.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-212Patterson Lake North · uraniumGrade: 0.1Grade Unit: %Intercept: 11 mView all detailsHide details
Identity
- Hole ID
- PLN25-212
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 11 m
- From
- 364 m
- To
- 375 m
- Intercept Depth
- 364 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-212:364-375
Location
- Easting
- 589368
- Northing
- 6397970
- Elevation
- 584 m
- Azimuth
- 40 °
- Dip
- -72 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a strong width with a grade above the weak threshold, contributing to overall mineralization.
Positive factors
- Strong width intercept (11.0m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.10”
Context: 11.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-212Patterson Lake North · uraniumGrade: 0.12Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- PLN25-212
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 10 m
- From
- 378 m
- To
- 388 m
- Intercept Depth
- 378 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-212:378-388
Location
- Easting
- 589368
- Northing
- 6397970
- Elevation
- 584 m
- Azimuth
- 40 °
- Dip
- -72 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a strong width with a grade above the weak threshold, contributing to overall mineralization.
Positive factors
- Strong width intercept (10.0m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.12”
Context: 10.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-212Patterson Lake North · uraniumGrade: 0.12Grade Unit: %Intercept: 6 mView all detailsHide details
Identity
- Hole ID
- PLN25-212
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 6 m
- From
- 394 m
- To
- 400 m
- Intercept Depth
- 394 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-212:394-400
Location
- Easting
- 589368
- Northing
- 6397970
- Elevation
- 584 m
- Azimuth
- 40 °
- Dip
- -72 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization.
Positive factors
- Moderate width intercept (6.0m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.12”
Context: 6.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-213W1Patterson Lake North · uraniumGrade: 0.08Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-213W1
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 279 m
- To
- 279.5 m
- Intercept Depth
- 279 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-213W1:279-279.5
Location
- Easting
- 589359
- Northing
- 6397959
- Elevation
- 584 m
- Azimuth
- 46 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.08”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-213W1Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-213W1
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 326 m
- To
- 326.5 m
- Intercept Depth
- 326 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-213W1:326-326.5
Location
- Easting
- 589359
- Northing
- 6397959
- Elevation
- 584 m
- Azimuth
- 46 °
- Dip
- -73 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.07”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-215Patterson Lake North · uraniumGrade: 0.08Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-215
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 249.5 m
- To
- 250 m
- Intercept Depth
- 249.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-215:249.5-250
Location
- Easting
- 587849
- Northing
- 6410603
- Elevation
- 546 m
- Azimuth
- 348 °
- Dip
- -59 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.08”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-216Patterson Lake North · uraniumGrade: 0.12Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-216
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 211.5 m
- To
- 212 m
- Intercept Depth
- 211.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-216:211.5-212
Location
- Easting
- 587778
- Northing
- 6410712
- Elevation
- 546 m
- Azimuth
- 55 °
- Dip
- -64 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.12”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.06Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 340.5 m
- To
- 341 m
- Intercept Depth
- 340.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:340.5-341
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.06”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 3.5 m
- From
- 355 m
- To
- 358.5 m
- Intercept Depth
- 355 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:355-358.5
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.07”
Context: 3.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.05Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 1.5 m
- From
- 361.5 m
- To
- 363 m
- Intercept Depth
- 361.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:361.5-363
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is at the cut-off grade, indicating marginal mineralization at the Tetra Zone.
Negative factors
- Low-grade uranium intercept, at cut-off.
- True thickness not determined.
Evidence · table
“0.05”
Context: 1.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 1 m
- From
- 365 m
- To
- 366 m
- Intercept Depth
- 365 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:365-366
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.07”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.19Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 369.5 m
- To
- 375 m
- Intercept Depth
- 369.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:369.5-375
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.
Positive factors
- Moderate width intercept (5.5m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.19”
Context: 5.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.14Grade Unit: %Intercept: 6.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 6.5 m
- From
- 377.5 m
- To
- 384 m
- Intercept Depth
- 377.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:377.5-384
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.
Positive factors
- Moderate width intercept (6.5m).
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.14”
Context: 6.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.41Grade Unit: %Intercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.41
- Grade Unit
- %
- Intercept
- 3.5 m
- From
- 388.5 m
- To
- 392 m
- Intercept Depth
- 388.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:388.5-392
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.41”
Context: 3.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.11Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 395.5 m
- To
- 396 m
- Intercept Depth
- 395.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:395.5-396
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.11”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.3Grade Unit: %Intercept: 3.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 3.5 m
- From
- 400 m
- To
- 403.5 m
- Intercept Depth
- 400 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:400-403.5
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.
Negative factors
- Grade is below strong threshold for uranium.
- True thickness not determined.
Evidence · table
“0.30”
Context: 3.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 1.04Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 1.04
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 400.5 m
- To
- 401 m
- Intercept Depth
- 400.5 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:400.5-401
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This narrow intercept shows a strong uranium grade, indicating a high-grade core within a wider zone at the Tetra Zone.
Positive factors
- High-grade uranium intercept (1.04% U3O8 exceeds 0.5% strong threshold for uranium).
Negative factors
- Narrow intercept length (0.5m).
- True thickness not determined.
Evidence · table
“1.04”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- PLN25-217
- Project
- Patterson Lake North
- Commodity
- uranium
- Region
- canada_sk
- Reported Region
- canada_sk
- Ticker
- FUU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 406 m
- To
- 406.5 m
- Intercept Depth
- 406 m
Classification
- Sample Type
- drill
- Group ID
- PLN25-217:406-406.5
Location
- Location
- Tetra Zone
- Easting
- 589393
- Northing
- 6398026
- Elevation
- 584 m
- Azimuth
- 34 °
- Dip
- -85 °
- Loc. Confidence
- medium
- Loc. Source
- document
QA/QC
- Laboratory
- SRC Geoanalytical Laboratories
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Compositing
- Cutoff Grade
- 0.05
- Cutoff Unit
- % U3O8
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-12-15T00:00:00.000Z
Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.
Negative factors
- Low-grade uranium intercept, near cut-off.
- True thickness not determined.
Evidence · table
“0.07”
Context: 0.50
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”
Compositing Transparentpositive
Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.
Evidence · text
“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”
No QA/QC Disclosurenegative
Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.
Why it applies: qaqc_disclosed is not true
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).
Evidence · text
“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.