F3 - Hits 2.5m of 10.2% U3O8 Within 3.4% over 8.5m at JR Zone

Original announcement by tmx on

Company
F3 Uranium Corp.
Ticker
FUU
Exchange
TSX
Region
Saskatchewan
Primary commodity
Uranium
Secondary commodities
None reported
Document categories
Drill results
Extracted
2026-09-17 23:02:53 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

F3 Uranium Corp. announced final assay results from its 2025 drill program at the PLN Property, highlighting high-grade uranium intercepts. Hole PLN25-200 at the JR Zone returned 8.5m of 3.4% U3O8, including 2.5m of 10.2% U3O8 and 1.0m of 20.7% U3O8. At the Tetra Zone, PLN25-217 confirmed high-grade mineralization 55m along strike from a discovery hole, with a 0.5m interval of 1.04% U3O8 within a wider 3.5m zone averaging 0.30% U3O8. These results will be incorporated into an upcoming maiden resource estimate for the JR Zone.

Reasoning: The announcement reports significant high-grade and ultra-high-grade uranium intercepts from the JR Zone and Tetra Zone, confirming mineralization continuity and potential for resource growth. The results are supported by robust QA/QC and contribute to an upcoming maiden resource estimate.

Positive factors

  • High-grade uranium intercepts in PLN25-200 and PLN25-217, including ultra-high grade sections.
  • Confirmation of additional high-grade mineralization 55m along strike at Tetra Zone, indicating potential for extension.
  • Comprehensive QA/QC disclosure with accredited lab and QP sign-off.
  • Upcoming maiden resource estimate for JR Zone.

Negative factors

  • True thicknesses are yet to be determined for all reported intercepts.
  • Some holes reported no mineralization above the cut-off, indicating variability.

Facts used in scoring: 35

Extracted facts

Stored fact records: 35. Some facts used in scoring do not have a stored record.

Drill Results (35)

PLN25-197Patterson Lake North · uraniumGrade: 1.08Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-197
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
1.08
Grade Unit
%
Intercept
1.5 m
From
207 m
To
208.5 m
Intercept Depth
207 m

Classification

Sample Type
drill
Group ID
PLN25-197:207-208.5

Location

Easting
587776
Northing
6410760
Elevation
546 m
Azimuth
55 °
Dip
-71 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a strong uranium grade, contributing positively to the project's prospectivity.

Positive factors

  • High-grade uranium intercept (1.08% U3O8 exceeds 0.5% strong threshold for uranium).

Negative factors

  • True thickness not determined.

Evidence · table

“1.08”

Context: 1.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-197Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-197
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.5 m
From
211 m
To
211.5 m
Intercept Depth
211 m

Classification

Sample Type
drill
Group ID
PLN25-197:211-211.5

Location

Easting
587776
Northing
6410760
Elevation
546 m
Azimuth
55 °
Dip
-71 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.07”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-198Patterson Lake North · uraniumGrade: 0.26Grade Unit: %Intercept: 7.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-198
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.26
Grade Unit
%
Intercept
7.5 m
From
215.5 m
To
223 m
Intercept Depth
215.5 m

Classification

Sample Type
drill
Group ID
PLN25-198:215.5-223

Location

Easting
587843
Northing
6410645
Elevation
546 m
Azimuth
9 °
Dip
-65 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization.

Positive factors

  • Moderate width intercept (7.5m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.26”

Context: 7.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-198Patterson Lake North · uraniumGrade: 1.33Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-198
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
1.33
Grade Unit
%
Intercept
0.5 m
From
220.5 m
To
221 m
Intercept Depth
220.5 m

Classification

Sample Type
drill
Group ID
PLN25-198:220.5-221

Location

Easting
587843
Northing
6410645
Elevation
546 m
Azimuth
9 °
Dip
-65 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This narrow intercept shows a strong uranium grade, indicating a high-grade core within a wider zone.

Positive factors

  • High-grade uranium intercept (1.33% U3O8 exceeds 0.5% strong threshold for uranium).

Negative factors

  • Narrow intercept length (0.5m).
  • True thickness not determined.

Evidence · table

“1.33”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-199Patterson Lake North · uraniumGrade: 0.29Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-199
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.29
Grade Unit
%
Intercept
1.5 m
From
242 m
To
243.5 m
Intercept Depth
242 m

Classification

Sample Type
drill
Group ID
PLN25-199:242-243.5

Location

Easting
587693
Northing
6410748
Elevation
545 m
Azimuth
55 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.29”

Context: 1.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 0.27Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
PLN25-200
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.27
Grade Unit
%
Intercept
2 m
From
234 m
To
236 m
Intercept Depth
234 m

Classification

Sample Type
drill
Group ID
PLN25-200:234-236

Location

Location
JR Zone
Easting
587731
Northing
6410712
Elevation
545 m
Azimuth
53 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization in the JR Zone.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.27”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 10.2Grade Unit: %Intercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-200
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
10.2
Grade Unit
%
Intercept
2.5 m
From
236 m
To
238.5 m
Intercept Depth
236 m

Classification

Sample Type
drill
Group ID
PLN25-200:236-238.5

Location

Location
JR Zone
Easting
587731
Northing
6410712
Elevation
545 m
Azimuth
53 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept represents an exceptional high-grade uranium zone, significantly enhancing the project's value and contributing to the upcoming resource estimate.

Positive factors

  • Bonanza grade uranium intercept (10.2% U3O8 exceeds 2% exceptional threshold for uranium).
  • Significant grade-width product (25.5 %·m).

Negative factors

  • True thickness not determined.

Evidence · table

“10.2”

Context: 2.50

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Exceptionally high-grade zone, well above the deposit-type norm (10.2% U3O8 exceeds 2% exceptional threshold).

Evidence · table

“10.2”

Context: 2.50

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 20.7Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
PLN25-200
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
20.7
Grade Unit
%
Intercept
1 m
From
237.5 m
To
238.5 m
Intercept Depth
237.5 m

Classification

Sample Type
drill
Group ID
PLN25-200:237.5-238.5

Location

Location
JR Zone
Easting
587731
Northing
6410712
Elevation
545 m
Azimuth
53 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept represents an ultra-high-grade uranium zone, significantly enhancing the project's value and contributing to the upcoming resource estimate.

Positive factors

  • Bonanza grade uranium intercept (20.7% U3O8 exceeds 2% exceptional threshold for uranium, and company defines >20% as ultra-high grade).
  • Significant grade-width product (20.7 %·m).

Negative factors

  • True thickness not determined.

Evidence · table

“20.7”

Context: 1.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Exceptionally high-grade zone, well above the deposit-type norm (20.7% U3O8 exceeds 2% exceptional threshold and company defines >20% as ultra-high grade).

Evidence · table

“20.7”

Context: 1.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 0.76Grade Unit: %Intercept: 4 mView all details
Link to this fact

Identity

Hole ID
PLN25-200
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.76
Grade Unit
%
Intercept
4 m
From
238.5 m
To
242.5 m
Intercept Depth
238.5 m

Classification

Sample Type
drill
Group ID
PLN25-200:238.5-242.5

Location

Location
JR Zone
Easting
587731
Northing
6410712
Elevation
545 m
Azimuth
53 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a strong uranium grade over a moderate width, contributing to the overall mineralization in the JR Zone.

Positive factors

  • Strong uranium grade (0.76% U3O8 exceeds 0.5% strong threshold for uranium).

Negative factors

  • True thickness not determined.

Evidence · table

“0.76”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 0.05Grade Unit: %Intercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-200
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.05
Grade Unit
%
Intercept
5.5 m
From
246.5 m
To
252 m
Intercept Depth
246.5 m

Classification

Sample Type
drill
Group ID
PLN25-200:246.5-252

Location

Location
JR Zone
Easting
587731
Northing
6410712
Elevation
545 m
Azimuth
53 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is at the cut-off grade, indicating marginal mineralization.

Negative factors

  • Low-grade uranium intercept, at cut-off.
  • True thickness not determined.

Evidence · table

“0.05”

Context: 5.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-200Patterson Lake North · uraniumGrade: 3.4Grade Unit: %Intercept: 8.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-200
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
3.4
Grade Unit
%
Intercept
8.5 m
From
234 m
To
242.5 m
Intercept Depth
234 m

Classification

Sample Type
drill
Group ID
PLN25-200:234-242.5

Location

Location
JR Zone
Easting
587731
Northing
6410712
Elevation
545 m
Azimuth
53 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This composite interval represents a significant high-grade uranium intercept, contributing strongly to the project's potential and upcoming resource estimate.

Positive factors

  • Exceptional uranium grade (3.4% U3O8 exceeds 2% exceptional threshold for uranium).
  • Strong width intercept (8.5m).
  • Significant grade-width product (28.9 %·m).

Negative factors

  • True thickness not determined.

Evidence · text

“8.5m of 3.4% U3O8”

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: Exceptionally high-grade zone, well above the deposit-type norm (3.4% U3O8 exceeds 2% exceptional threshold).

Evidence · text

“8.5m of 3.4% U3O8”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-207Patterson Lake North · uraniumGrade: 0.06Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-207
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.06
Grade Unit
%
Intercept
0.5 m
From
621 m
To
621.5 m
Intercept Depth
621 m

Classification

Sample Type
drill
Group ID
PLN25-207:621-621.5

Location

Location
Tetra Zone
Easting
589481
Northing
6397809
Elevation
587 m
Azimuth
46 °
Dip
-66 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept, while low-grade, is significant for indicating mineralization at depth and extending the known shear system.

Positive factors

  • Indicates mineralization at depth, associated with the Tetra Zone shear system.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.06”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake NorthView all details
Link to this fact

Identity

Hole ID
PLN25-210
Project
Patterson Lake North
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Classification

Sample Type
drill

Location

Easting
589341
Northing
6397997
Elevation
583 m
Azimuth
47 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.18”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.13Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-210
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.13
Grade Unit
%
Intercept
0.5 m
From
364 m
To
364.5 m
Intercept Depth
364 m

Classification

Sample Type
drill
Group ID
PLN25-210:364-364.5

Location

Easting
589341
Northing
6397997
Elevation
583 m
Azimuth
47 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.13”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.06Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-210
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.06
Grade Unit
%
Intercept
0.5 m
From
369.5 m
To
370 m
Intercept Depth
369.5 m

Classification

Sample Type
drill
Group ID
PLN25-210:369.5-370

Location

Easting
589341
Northing
6397997
Elevation
583 m
Azimuth
47 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.06”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.08Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-210
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.08
Grade Unit
%
Intercept
0.5 m
From
382.5 m
To
383 m
Intercept Depth
382.5 m

Classification

Sample Type
drill
Group ID
PLN25-210:382.5-383

Location

Easting
589341
Northing
6397997
Elevation
583 m
Azimuth
47 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.08”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-210Patterson Lake North · uraniumGrade: 0.14Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
PLN25-210
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.14
Grade Unit
%
Intercept
6 m
From
388.5 m
To
394.5 m
Intercept Depth
388.5 m

Classification

Sample Type
drill
Group ID
PLN25-210:388.5-394.5

Location

Easting
589341
Northing
6397997
Elevation
583 m
Azimuth
47 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization.

Positive factors

  • Moderate width intercept (6.0m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.14”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-212Patterson Lake North · uraniumGrade: 0.1Grade Unit: %Intercept: 11 mView all details
Link to this fact

Identity

Hole ID
PLN25-212
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.1
Grade Unit
%
Intercept
11 m
From
364 m
To
375 m
Intercept Depth
364 m

Classification

Sample Type
drill
Group ID
PLN25-212:364-375

Location

Easting
589368
Northing
6397970
Elevation
584 m
Azimuth
40 °
Dip
-72 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a strong width with a grade above the weak threshold, contributing to overall mineralization.

Positive factors

  • Strong width intercept (11.0m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.10”

Context: 11.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-212Patterson Lake North · uraniumGrade: 0.12Grade Unit: %Intercept: 10 mView all details
Link to this fact

Identity

Hole ID
PLN25-212
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.12
Grade Unit
%
Intercept
10 m
From
378 m
To
388 m
Intercept Depth
378 m

Classification

Sample Type
drill
Group ID
PLN25-212:378-388

Location

Easting
589368
Northing
6397970
Elevation
584 m
Azimuth
40 °
Dip
-72 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a strong width with a grade above the weak threshold, contributing to overall mineralization.

Positive factors

  • Strong width intercept (10.0m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.12”

Context: 10.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-212Patterson Lake North · uraniumGrade: 0.12Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
PLN25-212
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.12
Grade Unit
%
Intercept
6 m
From
394 m
To
400 m
Intercept Depth
394 m

Classification

Sample Type
drill
Group ID
PLN25-212:394-400

Location

Easting
589368
Northing
6397970
Elevation
584 m
Azimuth
40 °
Dip
-72 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization.

Positive factors

  • Moderate width intercept (6.0m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.12”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-213W1Patterson Lake North · uraniumGrade: 0.08Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-213W1
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.08
Grade Unit
%
Intercept
0.5 m
From
279 m
To
279.5 m
Intercept Depth
279 m

Classification

Sample Type
drill
Group ID
PLN25-213W1:279-279.5

Location

Easting
589359
Northing
6397959
Elevation
584 m
Azimuth
46 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.08”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-213W1Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-213W1
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.5 m
From
326 m
To
326.5 m
Intercept Depth
326 m

Classification

Sample Type
drill
Group ID
PLN25-213W1:326-326.5

Location

Easting
589359
Northing
6397959
Elevation
584 m
Azimuth
46 °
Dip
-73 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.07”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-215Patterson Lake North · uraniumGrade: 0.08Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-215
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.08
Grade Unit
%
Intercept
0.5 m
From
249.5 m
To
250 m
Intercept Depth
249.5 m

Classification

Sample Type
drill
Group ID
PLN25-215:249.5-250

Location

Easting
587849
Northing
6410603
Elevation
546 m
Azimuth
348 °
Dip
-59 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.08”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-216Patterson Lake North · uraniumGrade: 0.12Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-216
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.12
Grade Unit
%
Intercept
0.5 m
From
211.5 m
To
212 m
Intercept Depth
211.5 m

Classification

Sample Type
drill
Group ID
PLN25-216:211.5-212

Location

Easting
587778
Northing
6410712
Elevation
546 m
Azimuth
55 °
Dip
-64 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.12”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.06Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.06
Grade Unit
%
Intercept
0.5 m
From
340.5 m
To
341 m
Intercept Depth
340.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:340.5-341

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.06”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.07
Grade Unit
%
Intercept
3.5 m
From
355 m
To
358.5 m
Intercept Depth
355 m

Classification

Sample Type
drill
Group ID
PLN25-217:355-358.5

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.07”

Context: 3.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.05Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.05
Grade Unit
%
Intercept
1.5 m
From
361.5 m
To
363 m
Intercept Depth
361.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:361.5-363

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is at the cut-off grade, indicating marginal mineralization at the Tetra Zone.

Negative factors

  • Low-grade uranium intercept, at cut-off.
  • True thickness not determined.

Evidence · table

“0.05”

Context: 1.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.07
Grade Unit
%
Intercept
1 m
From
365 m
To
366 m
Intercept Depth
365 m

Classification

Sample Type
drill
Group ID
PLN25-217:365-366

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.07”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.19Grade Unit: %Intercept: 5.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.19
Grade Unit
%
Intercept
5.5 m
From
369.5 m
To
375 m
Intercept Depth
369.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:369.5-375

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.

Positive factors

  • Moderate width intercept (5.5m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.19”

Context: 5.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.14Grade Unit: %Intercept: 6.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.14
Grade Unit
%
Intercept
6.5 m
From
377.5 m
To
384 m
Intercept Depth
377.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:377.5-384

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a moderate width with a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.

Positive factors

  • Moderate width intercept (6.5m).

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.14”

Context: 6.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.41Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.41
Grade Unit
%
Intercept
3.5 m
From
388.5 m
To
392 m
Intercept Depth
388.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:388.5-392

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.41”

Context: 3.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.11Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.11
Grade Unit
%
Intercept
0.5 m
From
395.5 m
To
396 m
Intercept Depth
395.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:395.5-396

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.11”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.3Grade Unit: %Intercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.3
Grade Unit
%
Intercept
3.5 m
From
400 m
To
403.5 m
Intercept Depth
400 m

Classification

Sample Type
drill
Group ID
PLN25-217:400-403.5

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept shows a grade above the weak threshold, contributing to overall mineralization at the Tetra Zone.

Negative factors

  • Grade is below strong threshold for uranium.
  • True thickness not determined.

Evidence · table

“0.30”

Context: 3.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 1.04Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
1.04
Grade Unit
%
Intercept
0.5 m
From
400.5 m
To
401 m
Intercept Depth
400.5 m

Classification

Sample Type
drill
Group ID
PLN25-217:400.5-401

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This narrow intercept shows a strong uranium grade, indicating a high-grade core within a wider zone at the Tetra Zone.

Positive factors

  • High-grade uranium intercept (1.04% U3O8 exceeds 0.5% strong threshold for uranium).

Negative factors

  • Narrow intercept length (0.5m).
  • True thickness not determined.

Evidence · table

“1.04”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”
PLN25-217Patterson Lake North · uraniumGrade: 0.07Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
PLN25-217
Project
Patterson Lake North
Commodity
uranium
Region
canada_sk
Reported Region
canada_sk
Ticker
FUU

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.5 m
From
406 m
To
406.5 m
Intercept Depth
406 m

Classification

Sample Type
drill
Group ID
PLN25-217:406-406.5

Location

Location
Tetra Zone
Easting
589393
Northing
6398026
Elevation
584 m
Azimuth
34 °
Dip
-85 °
Loc. Confidence
medium
Loc. Source
document

QA/QC

Laboratory
SRC Geoanalytical Laboratories
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.05
Cutoff Unit
% U3O8
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-12-15T00:00:00.000Z

Reasoning: This intercept is low-grade but still above the stated cut-off, providing some continuity at the Tetra Zone.

Negative factors

  • Low-grade uranium intercept, near cut-off.
  • True thickness not determined.

Evidence · table

“0.07”

Context: 0.50

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“All depth measurements reported are down-hole and true thicknesses are yet to be determined.”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Evidence · text

“Assay composite parameters: 1: Minimum Thickness of 0.5 m 2: Assay Grade Cut-Off: 0.05% U3O8 (weight %) 3. Maximum Internal Dilution: 2.0 m”

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the Tetra Zone, assays confirm the presence of high grade uranium mineralization 55m along strike from discovery hole"

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: Release includes QA/QC disclosure — certified lab, QP sign-off, and stated methods (blanks, standards, duplicates).

Evidence · text

“Samples from the drill core are split into half sections on site. ... One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.”

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.