Fathom Announces New Zones of Mineralization Highlighting Exploration Potential of Recently Announced Gochager Lake Ni-Cu-Co Deposit Maiden MRE

Original announcement by investingnews on

Company
Fathom Nickel Inc.
Ticker
FNI
Exchange
CSE
Region
Saskatchewan, Canada
Primary commodity
Nickel
Secondary commodities
Copper, Cobalt, Platinum, Palladium, Gold
Document categories
Drill results, Resource update
Extracted
2026-09-16 15:22:39 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Fathom Nickel announced new drill results from its Phase-2 program at the Gochager Lake project, revealing new zones of nickel-copper-cobalt mineralization. These intercepts, including high-grade narrow sections and broader mineralized zones, are located outside and at depth from the recently announced maiden Mineral Resource Estimate, indicating strong potential for resource expansion. The program also confirmed the presence of platinum group elements within the deposit's mineralization system.

Reasoning: Fathom Nickel announced new drill results from its Phase-2 program at Gochager Lake, highlighting significant exploration potential to expand the recently announced maiden MRE. The program identified new zones of Ni-Cu-Co mineralization, including high-grade narrow intercepts and broader lower-grade zones, both outside and at depth from the current resource. The presence of PGEs was also confirmed. While true thickness is not yet determined, the results are positive for the project's growth.

Positive factors

  • Discovery of new zones of high-grade nickel-copper-cobalt mineralization outside the existing maiden MRE, indicating significant expansion potential.
  • Broad zones of mineralization intersected, including local higher-grade semi-massive to massive sulphide veins and breccias.
  • Confirmation of PGE mineralization with a notable platinum assay in GL26030.
  • QA/QC protocols are disclosed, and the results are verified by a Qualified Person from an accredited lab.

Negative factors

  • True thickness of intercepts is not yet determined, which introduces uncertainty regarding the actual width of mineralization.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 51

Extracted facts

Stored fact records: 51. Some facts used in scoring do not have a stored record.

Drill Results (51)

GL26029Gochager Lake · nickelGrade: 1.16Grade Unit: %Intercept: 0.48 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
1.16
Grade Unit
%
Intercept
0.48 m
From
204.62 m
To
205.1 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:204.62-205.1
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: High-grade nickel intercept from a new zone, showing strong exploration potential, but true width is unknown.

Positive factors

  • High-grade nickel intercept for a narrow interval.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“1.16”

Context: 0.48

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 1.16% Ni over 0.48m is an exceptionally high grade for nickel, well above the strong threshold for open pit mining.

Evidence · table

“1.16”

Context: 0.48

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · copperGrade: 0.51Grade Unit: %Intercept: 0.48 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.51
Grade Unit
%
Intercept
0.48 m
From
204.62 m
To
205.1 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:204.62-205.1
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Good copper intercept from a new zone, but true width is unknown.

Positive factors

  • Good copper grade for a narrow interval.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.51”

Context: 0.48

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · cobaltGrade: 0.12Grade Unit: %Intercept: 0.48 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.12
Grade Unit
%
Intercept
0.48 m
From
204.62 m
To
205.1 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:204.62-205.1
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Good cobalt intercept from a new zone, but true width is unknown.

Positive factors

  • Good cobalt grade for a narrow interval.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.12”

Context: 0.48

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · nickelGrade: 1.24Grade Unit: %Intercept: 0.51 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
1.24
Grade Unit
%
Intercept
0.51 m
From
210.1 m
To
210.61 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:210.1-210.61
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: High-grade nickel intercept from a new zone, showing strong exploration potential, but true width is unknown.

Positive factors

  • High-grade nickel intercept for a narrow interval.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“1.24”

Context: 0.51

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 1.24% Ni over 0.51m is an exceptionally high grade for nickel, well above the strong threshold for open pit mining.

Evidence · table

“1.24”

Context: 0.51

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · copperGrade: 0.19Grade Unit: %Intercept: 0.51 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.19
Grade Unit
%
Intercept
0.51 m
From
210.1 m
To
210.61 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:210.1-210.61
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for a narrow interval.

Evidence · table

“0.19”

Context: 0.51

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · cobaltGrade: 0.13Grade Unit: %Intercept: 0.51 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.13
Grade Unit
%
Intercept
0.51 m
From
210.1 m
To
210.61 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:210.1-210.61
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Good cobalt intercept from a new zone, but true width is unknown.

Positive factors

  • Good cobalt grade for a narrow interval.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.13”

Context: 0.51

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · nickelGrade: 0.42Grade Unit: %Intercept: 6.78 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.42
Grade Unit
%
Intercept
6.78 m
From
204.62 m
To
211.4 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:204.62-211.4
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Moderate nickel intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Moderate nickel grade over a good width.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.42”

Context: 6.78

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · copperGrade: 0.11Grade Unit: %Intercept: 6.78 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.11
Grade Unit
%
Intercept
6.78 m
From
204.62 m
To
211.4 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:204.62-211.4
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.11”

Context: 6.78

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · cobaltGrade: 0.04Grade Unit: %Intercept: 6.78 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.04
Grade Unit
%
Intercept
6.78 m
From
204.62 m
To
211.4 m
Hole Depth
374 m
Intercept Depth
204.62 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:204.62-211.4
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.04”

Context: 6.78

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · nickelGrade: 0.24Grade Unit: %Intercept: 21.44 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.24
Grade Unit
%
Intercept
21.44 m
From
199.13 m
To
220.57 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:199.13-220.57
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Significant nickel intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Significant width of nickel mineralization.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.24”

Context: 21.44

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · copperGrade: 0.07Grade Unit: %Intercept: 21.44 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.07
Grade Unit
%
Intercept
21.44 m
From
199.13 m
To
220.57 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:199.13-220.57
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.07”

Context: 21.44

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · cobaltGrade: 0.03Grade Unit: %Intercept: 21.44 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.03
Grade Unit
%
Intercept
21.44 m
From
199.13 m
To
220.57 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:199.13-220.57
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.03”

Context: 21.44

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · nickelGrade: 0.21Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.21
Grade Unit
%
Intercept
2 m
From
246 m
To
248 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:246-248
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Moderate nickel intercept from a new zone, but true width is unknown.

Positive factors

  • Moderate nickel grade over a narrow interval.
  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.21”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · copperGrade: 0.12Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.12
Grade Unit
%
Intercept
2 m
From
246 m
To
248 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:246-248
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.12”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · cobaltGrade: 0.03Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.03
Grade Unit
%
Intercept
2 m
From
246 m
To
248 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:246-248
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.03”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · nickelGrade: 0.15Grade Unit: %Intercept: 3.53 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.15
Grade Unit
%
Intercept
3.53 m
From
271.47 m
To
275 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:271.47-275
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.15”

Context: 3.53

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · copperGrade: 0.08Grade Unit: %Intercept: 3.53 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.08
Grade Unit
%
Intercept
3.53 m
From
271.47 m
To
275 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:271.47-275
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.08”

Context: 3.53

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26029Gochager Lake · cobaltGrade: 0.02Grade Unit: %Intercept: 3.53 mView all details
Link to this fact

Identity

Hole ID
GL26029
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.02
Grade Unit
%
Intercept
3.53 m
From
271.47 m
To
275 m
Hole Depth
374 m
Intercept Depth
199.13 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26029:271.47-275
Mining Method
unknown

Location

Easting
502223
Northing
6180249
CRS
NAD83 Zone 13
Elevation
419 m
Azimuth
152 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone, but true width is unknown.

Positive factors

  • Located outside the maiden MRE, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.02”

Context: 3.53

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26028Gochager Lake · nickelGrade: 0.5Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
GL26028
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.5
Grade Unit
%
Intercept
1.9 m
From
294.2 m
To
296.1 m
Hole Depth
419 m
Intercept Depth
277.82 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26028:294.2-296.1
Mining Method
unknown

Location

Easting
502435
Northing
6180464
CRS
NAD83 Zone 13
Elevation
424 m
Azimuth
135 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Strong nickel intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Strong nickel grade over a narrow interval.
  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.50”

Context: 1.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26028Gochager Lake · copperGrade: 0.09Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
GL26028
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.09
Grade Unit
%
Intercept
1.9 m
From
294.2 m
To
296.1 m
Hole Depth
419 m
Intercept Depth
277.82 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26028:294.2-296.1
Mining Method
unknown

Location

Easting
502435
Northing
6180464
CRS
NAD83 Zone 13
Elevation
424 m
Azimuth
135 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.09”

Context: 1.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26028Gochager Lake · cobaltGrade: 0.06Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
GL26028
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.06
Grade Unit
%
Intercept
1.9 m
From
294.2 m
To
296.1 m
Hole Depth
419 m
Intercept Depth
277.82 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26028:294.2-296.1
Mining Method
unknown

Location

Easting
502435
Northing
6180464
CRS
NAD83 Zone 13
Elevation
424 m
Azimuth
135 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.06”

Context: 1.90

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26028Gochager Lake · nickelGrade: 0.16Grade Unit: %Intercept: 34.69 mView all details
Link to this fact

Identity

Hole ID
GL26028
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.16
Grade Unit
%
Intercept
34.69 m
From
277.82 m
To
312.51 m
Hole Depth
419 m
Intercept Depth
277.82 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26028:277.82-312.51
Mining Method
unknown

Location

Easting
502435
Northing
6180464
CRS
NAD83 Zone 13
Elevation
424 m
Azimuth
135 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept over a significant width from a new zone at depth, but true width is unknown.

Positive factors

  • Significant width of nickel mineralization.
  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.16”

Context: 34.69

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26028Gochager Lake · copperGrade: 0.05Grade Unit: %Intercept: 34.69 mView all details
Link to this fact

Identity

Hole ID
GL26028
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.05
Grade Unit
%
Intercept
34.69 m
From
277.82 m
To
312.51 m
Hole Depth
419 m
Intercept Depth
277.82 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26028:277.82-312.51
Mining Method
unknown

Location

Easting
502435
Northing
6180464
CRS
NAD83 Zone 13
Elevation
424 m
Azimuth
135 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a significant width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.05”

Context: 34.69

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26028Gochager Lake · cobaltGrade: 0.02Grade Unit: %Intercept: 34.69 mView all details
Link to this fact

Identity

Hole ID
GL26028
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.02
Grade Unit
%
Intercept
34.69 m
From
277.82 m
To
312.51 m
Hole Depth
419 m
Intercept Depth
277.82 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26028:277.82-312.51
Mining Method
unknown

Location

Easting
502435
Northing
6180464
CRS
NAD83 Zone 13
Elevation
424 m
Azimuth
135 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a significant width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.02”

Context: 34.69

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · nickelGrade: 0.17Grade Unit: %Intercept: 4.92 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.17
Grade Unit
%
Intercept
4.92 m
From
136 m
To
140.92 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:136-140.92
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.17”

Context: 4.92

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · copperGrade: 0.06Grade Unit: %Intercept: 4.92 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.06
Grade Unit
%
Intercept
4.92 m
From
136 m
To
140.92 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:136-140.92
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.06”

Context: 4.92

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · cobaltGrade: 0.03Grade Unit: %Intercept: 4.92 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.03
Grade Unit
%
Intercept
4.92 m
From
136 m
To
140.92 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:136-140.92
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.03”

Context: 4.92

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · nickelGrade: 0.36Grade Unit: %Intercept: 2.33 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.36
Grade Unit
%
Intercept
2.33 m
From
379.33 m
To
381.66 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:379.33-381.66
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Strong nickel intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Strong nickel grade over a narrow interval.
  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.36”

Context: 2.33

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · copperGrade: 0.26Grade Unit: %Intercept: 2.33 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.26
Grade Unit
%
Intercept
2.33 m
From
379.33 m
To
381.66 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:379.33-381.66
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Good copper intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Good copper grade over a narrow interval.
  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.26”

Context: 2.33

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · cobaltGrade: 0.04Grade Unit: %Intercept: 2.33 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.04
Grade Unit
%
Intercept
2.33 m
From
379.33 m
To
381.66 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:379.33-381.66
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.04”

Context: 2.33

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · platinumGrade: 1.99Grade Unit: g/tIntercept: 0.31 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
platinum
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
1.99
Grade Unit
g/t
Intercept
0.31 m
From
379.33 m
To
379.64 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:379.33-379.64
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: High-grade platinum intercept confirming PGE presence, but true width is unknown.

Positive factors

  • Confirmation of PGE mineralization within the system.
  • High platinum grade for a narrow interval.

Negative factors

  • True thickness not determined.

Evidence · text

“1990ppb Pt”

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · palladiumGrade: 0.05Grade Unit: g/tIntercept: 0.31 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
palladium
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.31 m
From
379.33 m
To
379.64 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:379.33-379.64
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Good palladium intercept confirming PGE presence, but true width is unknown.

Positive factors

  • Confirmation of PGE mineralization within the system.
  • Good palladium grade for a narrow interval.

Negative factors

  • True thickness not determined.

Evidence · text

“50ppb Pd”

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · goldGrade: 0.03Grade Unit: g/tIntercept: 0.31 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
gold
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.31 m
From
379.33 m
To
379.64 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:379.33-379.64
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak gold intercept confirming PGE presence, but true width is unknown.

Positive factors

  • Confirmation of PGE mineralization within the system.

Negative factors

  • True thickness not determined.
  • Gold grade is weak for the width.

Evidence · text

“30ppb Au”

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · nickelGrade: 0.12Grade Unit: %Intercept: 54.79 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.12
Grade Unit
%
Intercept
54.79 m
From
368.32 m
To
423.11 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:368.32-423.11
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept over a very significant width from a new zone at depth, but true width is unknown.

Positive factors

  • Very significant width of nickel mineralization.
  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.12”

Context: 54.79

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · copperGrade: 0.05Grade Unit: %Intercept: 54.79 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.05
Grade Unit
%
Intercept
54.79 m
From
368.32 m
To
423.11 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:368.32-423.11
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a very significant width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.05”

Context: 54.79

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26030Gochager Lake · cobaltGrade: 0.01Grade Unit: %Intercept: 54.79 mView all details
Link to this fact

Identity

Hole ID
GL26030
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.01
Grade Unit
%
Intercept
54.79 m
From
368.32 m
To
423.11 m
Hole Depth
470 m
Intercept Depth
136 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26030:368.32-423.11
Mining Method
unknown

Location

Easting
502442
Northing
6180518
CRS
NAD83 Zone 13
Elevation
415 m
Azimuth
134 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a very significant width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.01”

Context: 54.79

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26032Gochager Lake · nickelGrade: 0.17Grade Unit: %Intercept: 5.45 mView all details
Link to this fact

Identity

Hole ID
GL26032
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.17
Grade Unit
%
Intercept
5.45 m
From
234.33 m
To
239.78 m
Hole Depth
440 m
Intercept Depth
234.33 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26032:234.33-239.78
Mining Method
unknown

Location

Easting
502341
Northing
6180461
CRS
NAD83 Zone 13
Elevation
422 m
Azimuth
123 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.17”

Context: 5.45

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26032Gochager Lake · copperGrade: 0.05Grade Unit: %Intercept: 5.45 mView all details
Link to this fact

Identity

Hole ID
GL26032
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.05
Grade Unit
%
Intercept
5.45 m
From
234.33 m
To
239.78 m
Hole Depth
440 m
Intercept Depth
234.33 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26032:234.33-239.78
Mining Method
unknown

Location

Easting
502341
Northing
6180461
CRS
NAD83 Zone 13
Elevation
422 m
Azimuth
123 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.05”

Context: 5.45

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26032Gochager Lake · cobaltGrade: 0.02Grade Unit: %Intercept: 5.45 mView all details
Link to this fact

Identity

Hole ID
GL26032
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.02
Grade Unit
%
Intercept
5.45 m
From
234.33 m
To
239.78 m
Hole Depth
440 m
Intercept Depth
234.33 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26032:234.33-239.78
Mining Method
unknown

Location

Easting
502341
Northing
6180461
CRS
NAD83 Zone 13
Elevation
422 m
Azimuth
123 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.02”

Context: 5.45

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26032Gochager Lake · nickelGrade: 0.13Grade Unit: %Intercept: 11.16 mView all details
Link to this fact

Identity

Hole ID
GL26032
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.13
Grade Unit
%
Intercept
11.16 m
From
419.7 m
To
430.86 m
Hole Depth
440 m
Intercept Depth
234.33 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26032:419.7-430.86
Mining Method
unknown

Location

Easting
502341
Northing
6180461
CRS
NAD83 Zone 13
Elevation
422 m
Azimuth
123 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept over a good width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.13”

Context: 11.16

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26032Gochager Lake · copperGrade: 0.07Grade Unit: %Intercept: 11.16 mView all details
Link to this fact

Identity

Hole ID
GL26032
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.07
Grade Unit
%
Intercept
11.16 m
From
419.7 m
To
430.86 m
Hole Depth
440 m
Intercept Depth
234.33 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26032:419.7-430.86
Mining Method
unknown

Location

Easting
502341
Northing
6180461
CRS
NAD83 Zone 13
Elevation
422 m
Azimuth
123 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a good width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.07”

Context: 11.16

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26032Gochager Lake · cobaltGrade: 0.02Grade Unit: %Intercept: 11.16 mView all details
Link to this fact

Identity

Hole ID
GL26032
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.02
Grade Unit
%
Intercept
11.16 m
From
419.7 m
To
430.86 m
Hole Depth
440 m
Intercept Depth
234.33 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26032:419.7-430.86
Mining Method
unknown

Location

Easting
502341
Northing
6180461
CRS
NAD83 Zone 13
Elevation
422 m
Azimuth
123 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a good width from a new zone at depth, but true width is unknown.

Positive factors

  • Located in a new mineralized zone at depth, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.02”

Context: 11.16

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26027Gochager Lake · nickelGrade: 0.37Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
GL26027
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.37
Grade Unit
%
Intercept
1.52 m
From
261.81 m
To
263.33 m
Hole Depth
458 m
Intercept Depth
261.81 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26027:261.81-263.33
Mining Method
unknown

Location

Easting
502597
Northing
6180516
CRS
NAD83 Zone 13
Elevation
405 m
Azimuth
135 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Strong nickel intercept from a new zone, but true width is unknown.

Positive factors

  • Strong nickel grade over a narrow interval.
  • Located in a new mineralized zone, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.37”

Context: 1.52

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26027Gochager Lake · copperGrade: 0.27Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
GL26027
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.27
Grade Unit
%
Intercept
1.52 m
From
261.81 m
To
263.33 m
Hole Depth
458 m
Intercept Depth
261.81 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26027:261.81-263.33
Mining Method
unknown

Location

Easting
502597
Northing
6180516
CRS
NAD83 Zone 13
Elevation
405 m
Azimuth
135 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Good copper intercept from a new zone, but true width is unknown.

Positive factors

  • Good copper grade over a narrow interval.
  • Located in a new mineralized zone, indicating expansion potential.

Negative factors

  • True thickness not determined.

Evidence · table

“0.27”

Context: 1.52

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26027Gochager Lake · cobaltGrade: 0.04Grade Unit: %Intercept: 1.52 mView all details
Link to this fact

Identity

Hole ID
GL26027
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.04
Grade Unit
%
Intercept
1.52 m
From
261.81 m
To
263.33 m
Hole Depth
458 m
Intercept Depth
261.81 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26027:261.81-263.33
Mining Method
unknown

Location

Easting
502597
Northing
6180516
CRS
NAD83 Zone 13
Elevation
405 m
Azimuth
135 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.2
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.04”

Context: 1.52

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26027Gochager Lake · nickelGrade: 0.17Grade Unit: %Intercept: 4.19 mView all details
Link to this fact

Identity

Hole ID
GL26027
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.17
Grade Unit
%
Intercept
4.19 m
From
261.81 m
To
265.11 m
Hole Depth
458 m
Intercept Depth
261.81 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26027:261.81-265.11
Mining Method
unknown

Location

Easting
502597
Northing
6180516
CRS
NAD83 Zone 13
Elevation
405 m
Azimuth
135 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.17”

Context: 4.19

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26027Gochager Lake · copperGrade: 0.09Grade Unit: %Intercept: 4.19 mView all details
Link to this fact

Identity

Hole ID
GL26027
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.09
Grade Unit
%
Intercept
4.19 m
From
261.81 m
To
265.11 m
Hole Depth
458 m
Intercept Depth
261.81 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26027:261.81-265.11
Mining Method
unknown

Location

Easting
502597
Northing
6180516
CRS
NAD83 Zone 13
Elevation
405 m
Azimuth
135 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.09”

Context: 4.19

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26027Gochager Lake · cobaltGrade: 0.02Grade Unit: %Intercept: 4.19 mView all details
Link to this fact

Identity

Hole ID
GL26027
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.02
Grade Unit
%
Intercept
4.19 m
From
261.81 m
To
265.11 m
Hole Depth
458 m
Intercept Depth
261.81 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26027:261.81-265.11
Mining Method
unknown

Location

Easting
502597
Northing
6180516
CRS
NAD83 Zone 13
Elevation
405 m
Azimuth
135 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating expansion potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.02”

Context: 4.19

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26026Gochager Lake · nickelGrade: 0.1Grade Unit: %Intercept: 4.04 mView all details
Link to this fact

Identity

Hole ID
GL26026
Project
Gochager Lake
Commodity
nickel
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.1
Grade Unit
%
Intercept
4.04 m
From
226.18 m
To
230.22 m
Hole Depth
389 m
Intercept Depth
226.18 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26026:226.18-230.22
Mining Method
unknown

Location

Easting
502738
Northing
6180613
CRS
NAD83 Zone 13
Elevation
410 m
Azimuth
125 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak nickel intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating exploration potential.

Negative factors

  • True thickness not determined.
  • Nickel grade is weak for the width.

Evidence · table

“0.10”

Context: 4.04

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26026Gochager Lake · copperGrade: 0.02Grade Unit: %Intercept: 4.04 mView all details
Link to this fact

Identity

Hole ID
GL26026
Project
Gochager Lake
Commodity
copper
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.02
Grade Unit
%
Intercept
4.04 m
From
226.18 m
To
230.22 m
Hole Depth
389 m
Intercept Depth
226.18 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26026:226.18-230.22
Mining Method
unknown

Location

Easting
502738
Northing
6180613
CRS
NAD83 Zone 13
Elevation
410 m
Azimuth
125 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak copper intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating exploration potential.

Negative factors

  • True thickness not determined.
  • Copper grade is weak for the width.

Evidence · table

“0.02”

Context: 4.04

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

GL26026Gochager Lake · cobaltGrade: 0.01Grade Unit: %Intercept: 4.04 mView all details
Link to this fact

Identity

Hole ID
GL26026
Project
Gochager Lake
Commodity
cobalt
Region
canada_sk
Reported Region
canada_sk
Ticker
FNI

Geometry

Grade
0.01
Grade Unit
%
Intercept
4.04 m
From
226.18 m
To
230.22 m
Hole Depth
389 m
Intercept Depth
226.18 m

Classification

Program
mixed
Sample Type
drill
Group ID
GL26026:226.18-230.22
Mining Method
unknown

Location

Easting
502738
Northing
6180613
CRS
NAD83 Zone 13
Elevation
410 m
Azimuth
125 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Canada Ltd.
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
% Ni

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-16T00:00:00.000Z

Reasoning: Weak cobalt intercept over a good width from a new zone, but true width is unknown.

Positive factors

  • Located in a new mineralized zone, indicating exploration potential.

Negative factors

  • True thickness not determined.
  • Cobalt grade is weak for the width.

Evidence · table

“0.01”

Context: 4.04

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intervals are downhole and not true thickness, with insufficient data to determine true thickness.

Evidence · text

“*Interval (m) are downhole intervals and not true thickness. Insufficient data currently to determine true thickness.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes disclosure of QA/QC protocols, certified lab, and QP sign-off.

Evidence · text

“Fathom implements an industry-standard QA/QC protocol for all field and diamond drill programs.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "Highlights: Drillhole GL26029 intersected semi-massive to massive pyrrhotite-pentlandite-chalcopyrite veins and breccias"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.