First Andes Silver Reports High-Grade Silver Assays, Santas Gloria Project, Peru
Original announcement by tmx on
- Company
- First Andes Silver Ltd.
- Ticker
- FAS
- Exchange
- TSX
- Region
- Peru
- Primary commodity
- Silver
- Secondary commodities
- Gold, Lead, Zinc
- Document categories
- Drill results
- Extracted
- 2026-09-12 05:35:30 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
First Andes Silver announced high-grade silver assay results from its 2,000-meter drill program at the Santas Gloria Project in Peru. Key intercepts include 606.2 g/t Ag over 0.70 m within 3.90 m at 248.5 g/t Ag in hole SG022, and 533.8 g/t Ag over 0.60 m within 6.20 m at 164.8 g/t Ag in hole SG017. The results confirm an intermediate sulphidation epithermal system with potential for a sulphide-rich system at depth, with additional drill pads being permitted.
Reasoning: The drill program returned multiple high-grade silver intercepts, including bonanza grades, confirming the prospectivity of the Santas Gloria project. The geological interpretation suggests a preserved sulphide-rich system at depth, indicating significant exploration upside. While true widths are not yet determined and some assays are pending, the disclosed results are strong and well-supported by QA/QC.
Positive factors
- High-grade silver intercepts, including bonanza grades up to 606.2 g/t Ag.
- Confirmation of an intermediate sulphidation epithermal system with depth potential.
- Detailed QA/QC disclosure and QP sign-off.
- Metal equivalent assumptions are fully disclosed.
Negative factors
- True widths are yet to be determined for all reported intercepts.
- Several holes have assays pending, limiting the full scope of results.
- Historical mining voids were intercepted in some holes, which could complicate future mining.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 80
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Hole SG017 reported 533.8 g/t Ag over 0.60 m, which exceeds the 500 g/t silver exceptional threshold.
Evidence · table
“533.8”
Context: 0.60
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Hole SG022 reported 606.2 g/t Ag over 0.70 m, which exceeds the 500 g/t silver exceptional threshold.
Evidence · table
“606.2”
Context: 0.70
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The document explicitly states that 'Interval lengths represent drill core lengths, true widths are yet to be determined'.
Evidence · text
“*Interval lengths represent drill core lengths, true widths are yet to be determined”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release includes detailed QA/QC disclosure, naming AHK Group as the ISO/IEC 17025 and ISO 9001 certified lab, mentioning chain of custody, fire assay and ICP analysis, and QP sign-off by Dr. Christopher Wilson.
Evidence · text
“The Company follows industry-recognized standards of Best Practice and QA/QC. HQ-diameter core samples are sawed into equal halves, and selected ½ core samples are submitted to AHK Group in in Lima, Peru, a market-leading provider of inspection and analysis services which maintains rigorous quality standards through compliance with industry standards and regulations, including ISO/IEC 17025 and ISO 9001. Core samples are sealed in plastic bags using single use tie-locks, thereby ensuring chain of custody, for fire assay and ICP analysis. To date, all batches have passed QA/QC within acceptable tolerance limits. All diamond holes were drilled in PQ-NQ diameter. Core recovery across all veins exceeded 90%.”
Extracted facts
Stored fact records: 80. Some facts used in scoring do not have a stored record.
Drill Results (80)
SG016Santas Gloria · silverGrade: 109.1Grade Unit: g/tIntercept: 2.04 mView all detailsHide details
Identity
- Hole ID
- SG016
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 109.1
- Grade Unit
- g/t
- Intercept
- 2.04 m
- From
- 74.96 m
- To
- 77 m
- Hole Depth
- 78.4 m
- Intercept Depth
- 74.96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG016:74.96-77
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 124.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a narrow width, contributing to the overall prospectivity of the project.
Positive factors
- Solid silver grade for the width.
- Part of a broader high-grade silver system.
Negative factors
- True width not determined.
Evidence · table
“109.1”
Context: 2.04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG016Santas Gloria · goldGrade: 0.04Grade Unit: g/tIntercept: 2.04 mView all detailsHide details
Identity
- Hole ID
- SG016
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 2.04 m
- From
- 74.96 m
- To
- 77 m
- Hole Depth
- 78.4 m
- Intercept Depth
- 74.96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG016:74.96-77
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 124.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.04”
Context: 2.04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG016Santas Gloria · leadGrade: 0.35Grade Unit: %Intercept: 2.04 mView all detailsHide details
Identity
- Hole ID
- SG016
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 2.04 m
- From
- 74.96 m
- To
- 77 m
- Hole Depth
- 78.4 m
- Intercept Depth
- 74.96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG016:74.96-77
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 124.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.35”
Context: 2.04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG016Santas Gloria · zincGrade: 0.2Grade Unit: %Intercept: 2.04 mView all detailsHide details
Identity
- Hole ID
- SG016
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 2.04 m
- From
- 74.96 m
- To
- 77 m
- Hole Depth
- 78.4 m
- Intercept Depth
- 74.96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG016:74.96-77
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 124.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.20”
Context: 2.04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 168.8Grade Unit: g/tIntercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 168.8
- Grade Unit
- g/t
- Intercept
- 2.3 m
- From
- 165.8 m
- To
- 168.1 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:165.8-168.1
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 195.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This intercept shows good silver grades and indicates continuity of mineralization, with higher-grade zones within.
Positive factors
- Strong silver grade over a moderate width.
- Contains higher-grade sub-intervals.
Negative factors
- True width not determined.
Evidence · table
“168.8”
Context: 2.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.21Grade Unit: g/tIntercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 2.3 m
- From
- 165.8 m
- To
- 168.1 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:165.8-168.1
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 195.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.21”
Context: 2.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.15Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.15
- Grade Unit
- %
- Intercept
- 2.3 m
- From
- 165.8 m
- To
- 168.1 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:165.8-168.1
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 195.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.15”
Context: 2.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.28Grade Unit: %Intercept: 2.3 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 2.3 m
- From
- 165.8 m
- To
- 168.1 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:165.8-168.1
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 195.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.28”
Context: 2.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 387.1Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 387.1
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 166.6 m
- To
- 167.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:166.6-167.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 418.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This sub-interval represents a significant high-grade silver zone within a broader intercept, indicating strong mineralization.
Positive factors
- Very high-grade silver intercept.
Negative factors
- Narrow width.
- True width not determined.
Evidence · table
“387.1”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.24Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 166.6 m
- To
- 167.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:166.6-167.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 418.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.24”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.25Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 0.8 m
- From
- 166.6 m
- To
- 167.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:166.6-167.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 418.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.25”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.29Grade Unit: %Intercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 0.8 m
- From
- 166.6 m
- To
- 167.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:166.6-167.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 418.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.29”
Context: 0.80
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 164.8Grade Unit: g/tIntercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 164.8
- Grade Unit
- g/t
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:174.7-180.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 190.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This is a material intercept with good silver grades over a substantial width, indicating a robust mineralized zone with very high-grade pockets.
Positive factors
- Strong silver grade over a significant width.
- Contains multiple high-grade sub-intervals, including bonanza grades.
Negative factors
- True width not determined.
Evidence · table
“164.8”
Context: 6.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.2Grade Unit: g/tIntercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:174.7-180.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 190.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.20”
Context: 6.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.17Grade Unit: %Intercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:174.7-180.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 190.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.17”
Context: 6.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.23Grade Unit: %Intercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:174.7-180.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 190.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.23”
Context: 6.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 238.7Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 238.7
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:175.9-176.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 271.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade, contributing to the overall high-grade nature of the broader intercept.
Positive factors
- High-grade silver intercept.
Negative factors
- Narrow width.
- True width not determined.
Evidence · table
“238.7”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.27Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:175.9-176.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 271.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.27”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.11Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:175.9-176.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 271.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.11”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.35Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:175.9-176.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 271.5
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.35”
Context: 0.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 533.8Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 533.8
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:176.8-177.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 578.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept, indicating extremely high-grade mineralization within the system, despite its narrow width.
Positive factors
- Exceptional bonanza-grade silver intercept.
Negative factors
- Very narrow width.
- True width not determined.
Evidence · table
“533.8”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.32Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:176.8-177.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 578.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.32”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.24Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:176.8-177.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 578.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.24”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.57Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.57
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:176.8-177.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 578.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Moderate zinc grade, contributing to the overall polymetallic value of the intercept.
Evidence · table
“0.57”
Context: 0.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 256.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 256.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:179.8-180.3
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 289.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade, contributing to the overall high-grade nature of the broader intercept.
Positive factors
- High-grade silver intercept.
Negative factors
- Very narrow width.
- True width not determined.
Evidence · table
“256.1”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.16Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:179.8-180.3
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 289.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.16”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.63Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.63
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:179.8-180.3
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 289.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Moderate lead grade, contributing to the overall polymetallic value of the intercept.
Evidence · table
“0.63”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.29Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:179.8-180.3
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 289.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.29”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · silverGrade: 220.7Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 220.7
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:193.2-193.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 240.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade, indicating continued mineralization at depth.
Positive factors
- High-grade silver intercept.
Negative factors
- Narrow width.
- True width not determined.
Evidence · table
“220.7”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · goldGrade: 0.1Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:193.2-193.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 240.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.10”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · leadGrade: 0.18Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.18
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:193.2-193.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 240.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.18”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG017Santas Gloria · zincGrade: 0.35Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG017
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Hole Depth
- 194.2 m
- Intercept Depth
- 165.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG017:193.2-193.9
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 320 °
- Dip
- -62 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 240.9
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.35”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · silverGrade: 198.1Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 198.1
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 87.3 m
- To
- 88.4 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-88.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 211.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This intercept shows good silver grades and indicates continuity of mineralization, with higher-grade zones within.
Positive factors
- Strong silver grade over a narrow width.
- Contains higher-grade sub-intervals.
Negative factors
- True width not determined.
Evidence · table
“198.1”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · goldGrade: 0.1Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 87.3 m
- To
- 88.4 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-88.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 211.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.10”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · leadGrade: 0.19Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 87.3 m
- To
- 88.4 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-88.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 211.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.19”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · zincGrade: 0.4Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 87.3 m
- To
- 88.4 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-88.4
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 211.6
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.40”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · silverGrade: 321.6Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 321.6
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 87.3 m
- To
- 87.8 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-87.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 346.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This sub-interval represents a significant high-grade silver zone within a broader intercept, indicating strong mineralization.
Positive factors
- Very high-grade silver intercept.
Negative factors
- Very narrow width.
- True width not determined.
Evidence · table
“321.6”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · goldGrade: 0.08Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 87.3 m
- To
- 87.8 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-87.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 346.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.08”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · leadGrade: 0.3Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 87.3 m
- To
- 87.8 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-87.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 346.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.30”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG018Santas Gloria · zincGrade: 0.5Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG018
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 87.3 m
- To
- 87.8 m
- Hole Depth
- 119.1 m
- Intercept Depth
- 87.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG018:87.3-87.8
Location
- Easting
- 344742
- Northing
- 8668326
- Azimuth
- 40 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 346.3
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Moderate zinc grade, contributing to the overall polymetallic value of the intercept.
Evidence · table
“0.50”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · silverGrade: 332.1Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 332.1
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 109.8 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:109.8-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 350.4
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This intercept shows very strong silver grades over a narrow width, indicating a significant high-grade zone.
Positive factors
- Very high-grade silver intercept.
- Contains higher-grade sub-intervals.
Negative factors
- True width not determined.
Evidence · table
“332.1”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · goldGrade: 0.11Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 109.8 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:109.8-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 350.4
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.11”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · leadGrade: 0.1Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 109.8 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:109.8-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 350.4
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.10”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · zincGrade: 0.68Grade Unit: %Intercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 1.1 m
- From
- 109.8 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:109.8-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 350.4
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Moderate zinc grade, contributing to the overall polymetallic value of the intercept.
Evidence · table
“068”
Context: 1.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · silverGrade: 392.4Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 392.4
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 110.4 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:110.4-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 443.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This sub-interval represents a significant high-grade silver zone within a broader intercept, indicating strong mineralization.
Positive factors
- Very high-grade silver intercept.
Negative factors
- Very narrow width.
- True width not determined.
Evidence · table
“392.4”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · goldGrade: 0.13Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 110.4 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:110.4-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 443.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.13”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · leadGrade: 0.23Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 110.4 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:110.4-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 443.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.23”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG019Santas Gloria · zincGrade: 0.38Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG019
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.38
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 110.4 m
- To
- 110.9 m
- Hole Depth
- 113.6 m
- Intercept Depth
- 109.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG019:110.4-110.9
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 50 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 443.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.38”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG020Santas Gloria · silverGrade: 239.4Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG020
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 239.4
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 158 m
- To
- 158.5 m
- Hole Depth
- 165.1 m
- Intercept Depth
- 158 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG020:158-158.5
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 63 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 260.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade, indicating continued mineralization.
Positive factors
- High-grade silver intercept.
Negative factors
- Very narrow width.
- True width not determined.
Evidence · table
“239.4”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG020Santas Gloria · goldGrade: 0.11Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG020
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 158 m
- To
- 158.5 m
- Hole Depth
- 165.1 m
- Intercept Depth
- 158 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG020:158-158.5
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 63 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 260.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.11”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG020Santas Gloria · leadGrade: 0.13Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG020
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 158 m
- To
- 158.5 m
- Hole Depth
- 165.1 m
- Intercept Depth
- 158 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG020:158-158.5
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 63 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 260.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.13”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG020Santas Gloria · zincGrade: 0.38Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- SG020
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.38
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 158 m
- To
- 158.5 m
- Hole Depth
- 165.1 m
- Intercept Depth
- 158 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG020:158-158.5
Location
- Easting
- 344840
- Northing
- 8668339
- Azimuth
- 63 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 260.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.38”
Context: 0.50
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · silverGrade: 248.5Grade Unit: g/tIntercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 248.5
- Grade Unit
- g/t
- Intercept
- 3.9 m
- From
- 91.9 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:91.9-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 268.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This is a material intercept with high silver grades over a good width, indicating a robust mineralized zone with bonanza-grade pockets.
Positive factors
- High-grade silver intercept over a good width.
- Contains bonanza-grade sub-intervals.
Negative factors
- True width not determined.
Evidence · table
“248.5”
Context: 3.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · goldGrade: 0.12Grade Unit: g/tIntercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
- Intercept
- 3.9 m
- From
- 91.9 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:91.9-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 268.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.12”
Context: 3.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · leadGrade: 0.32Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 3.9 m
- From
- 91.9 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:91.9-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 268.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.32”
Context: 3.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · zincGrade: 0.14Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.14
- Grade Unit
- %
- Intercept
- 3.9 m
- From
- 91.9 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:91.9-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 268.2
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.14”
Context: 3.90
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · silverGrade: 606.2Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 606.2
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 95.1 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:95.1-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 638.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: This is a bonanza-grade silver intercept, indicating extremely high-grade mineralization within the system, despite its narrow width.
Positive factors
- Exceptional bonanza-grade silver intercept.
Negative factors
- Very narrow width.
- True width not determined.
Evidence · table
“606.2”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · goldGrade: 0.18Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 95.1 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:95.1-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 638.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.18”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · leadGrade: 0.68Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 95.1 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:95.1-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 638.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Moderate lead grade, contributing to the overall polymetallic value of the intercept.
Evidence · table
“0.68”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
SG022Santas Gloria · zincGrade: 0.12Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- SG022
- Project
- Santas Gloria
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 95.1 m
- To
- 95.8 m
- Hole Depth
- 98.7 m
- Intercept Depth
- 91.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- SG022:95.1-95.8
Location
- Easting
- 344838
- Northing
- 8668340
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Metal Eq. Grade
- 638.1
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.
Evidence · table
“0.12”
Context: 0.70
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 164.8Grade Unit: g/tIntercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 164.8
- Grade Unit
- g/t
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Intercept Depth
- 174.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:174.7-180.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 164.8 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1021.8 g/t·m is moderate.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“164.8”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.2Grade Unit: g/tIntercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Intercept Depth
- 174.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:174.7-180.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.2 g/t·m is below.
Negative factors
- 0.2 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.20”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.17Grade Unit: %Intercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Intercept Depth
- 174.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:174.7-180.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.17 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.1 %·m is below.
Negative factors
- 0.17 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.17”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.23Grade Unit: %Intercept: 6.2 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 6.2 m
- From
- 174.7 m
- To
- 180.9 m
- Intercept Depth
- 174.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:174.7-180.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.23 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.4 %·m is below.
Negative factors
- 0.23 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.23”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 238.7Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 238.7
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Intercept Depth
- 175.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:175.9-176.8
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 238.7 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 214.8 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 238.7 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“238.7”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.27Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Intercept Depth
- 175.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:175.9-176.8
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.27 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.11Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Intercept Depth
- 175.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:175.9-176.8
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.11 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.35Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 175.9 m
- To
- 176.8 m
- Intercept Depth
- 175.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:175.9-176.8
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.35 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.35 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.35”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 533.8Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 533.8
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Intercept Depth
- 176.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:176.8-177.4
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 533.8 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 320.3 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 533.8 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“533.8”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.32Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Intercept Depth
- 176.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:176.8-177.4
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.32 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.32”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.24Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Intercept Depth
- 176.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:176.8-177.4
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.24 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.24 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.24”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.57Grade Unit: %Intercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.57
- Grade Unit
- %
- Intercept
- 0.6 m
- From
- 176.8 m
- To
- 177.4 m
- Intercept Depth
- 176.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:176.8-177.4
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.57 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.57 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.57”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 256.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 256.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Intercept Depth
- 179.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:179.8-180.3
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 256.1 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 128.1 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 256.1 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“256.1”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.16Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Intercept Depth
- 179.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:179.8-180.3
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.16 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.63Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.63
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Intercept Depth
- 179.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:179.8-180.3
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.63 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.63 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.63”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.29Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 179.8 m
- To
- 180.3 m
- Intercept Depth
- 179.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:179.8-180.3
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.29 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.29 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.29”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 220.7Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 220.7
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Intercept Depth
- 193.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:193.2-193.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 220.7 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 154.5 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 220.7 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“220.7”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.1Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Intercept Depth
- 193.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:193.2-193.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.18Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.18
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Intercept Depth
- 193.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:193.2-193.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.18 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.35Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- And
- Project
- mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- FAS
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 193.2 m
- To
- 193.9 m
- Intercept Depth
- 193.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- And:193.2-193.9
QA/QC
- Laboratory
- AHK Group
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-08-21T00:00:00.000Z
Reasoning: Expanded from assay table. 0.35 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.35 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.35”
Context: And
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.