First Andes Silver Reports High-Grade Silver Assays, Santas Gloria Project, Peru

Original announcement by tmx on

Company
First Andes Silver Ltd.
Ticker
FAS
Exchange
TSX
Region
Peru
Primary commodity
Silver
Secondary commodities
Gold, Lead, Zinc
Document categories
Drill results
Extracted
2026-09-12 05:35:30 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

First Andes Silver announced high-grade silver assay results from its 2,000-meter drill program at the Santas Gloria Project in Peru. Key intercepts include 606.2 g/t Ag over 0.70 m within 3.90 m at 248.5 g/t Ag in hole SG022, and 533.8 g/t Ag over 0.60 m within 6.20 m at 164.8 g/t Ag in hole SG017. The results confirm an intermediate sulphidation epithermal system with potential for a sulphide-rich system at depth, with additional drill pads being permitted.

Reasoning: The drill program returned multiple high-grade silver intercepts, including bonanza grades, confirming the prospectivity of the Santas Gloria project. The geological interpretation suggests a preserved sulphide-rich system at depth, indicating significant exploration upside. While true widths are not yet determined and some assays are pending, the disclosed results are strong and well-supported by QA/QC.

Positive factors

  • High-grade silver intercepts, including bonanza grades up to 606.2 g/t Ag.
  • Confirmation of an intermediate sulphidation epithermal system with depth potential.
  • Detailed QA/QC disclosure and QP sign-off.
  • Metal equivalent assumptions are fully disclosed.

Negative factors

  • True widths are yet to be determined for all reported intercepts.
  • Several holes have assays pending, limiting the full scope of results.
  • Historical mining voids were intercepted in some holes, which could complicate future mining.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 80

Classification and evidence

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole SG017 reported 533.8 g/t Ag over 0.60 m, which exceeds the 500 g/t silver exceptional threshold.

Evidence · table

“533.8”

Context: 0.60

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole SG022 reported 606.2 g/t Ag over 0.70 m, which exceeds the 500 g/t silver exceptional threshold.

Evidence · table

“606.2”

Context: 0.70

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'Interval lengths represent drill core lengths, true widths are yet to be determined'.

Evidence · text

“*Interval lengths represent drill core lengths, true widths are yet to be determined”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes detailed QA/QC disclosure, naming AHK Group as the ISO/IEC 17025 and ISO 9001 certified lab, mentioning chain of custody, fire assay and ICP analysis, and QP sign-off by Dr. Christopher Wilson.

Evidence · text

“The Company follows industry-recognized standards of Best Practice and QA/QC. HQ-diameter core samples are sawed into equal halves, and selected ½ core samples are submitted to AHK Group in in Lima, Peru, a market-leading provider of inspection and analysis services which maintains rigorous quality standards through compliance with industry standards and regulations, including ISO/IEC 17025 and ISO 9001. Core samples are sealed in plastic bags using single use tie-locks, thereby ensuring chain of custody, for fire assay and ICP analysis. To date, all batches have passed QA/QC within acceptable tolerance limits. All diamond holes were drilled in PQ-NQ diameter. Core recovery across all veins exceeded 90%.”

Extracted facts

Stored fact records: 80. Some facts used in scoring do not have a stored record.

Drill Results (80)

SG016Santas Gloria · silverGrade: 109.1Grade Unit: g/tIntercept: 2.04 mView all details
Link to this fact

Identity

Hole ID
SG016
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
109.1
Grade Unit
g/t
Intercept
2.04 m
From
74.96 m
To
77 m
Hole Depth
78.4 m
Intercept Depth
74.96 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG016:74.96-77

Location

Easting
344742
Northing
8668326
Azimuth
10 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
124.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a narrow width, contributing to the overall prospectivity of the project.

Positive factors

  • Solid silver grade for the width.
  • Part of a broader high-grade silver system.

Negative factors

  • True width not determined.

Evidence · table

“109.1”

Context: 2.04

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG016Santas Gloria · goldGrade: 0.04Grade Unit: g/tIntercept: 2.04 mView all details
Link to this fact

Identity

Hole ID
SG016
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
2.04 m
From
74.96 m
To
77 m
Hole Depth
78.4 m
Intercept Depth
74.96 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG016:74.96-77

Location

Easting
344742
Northing
8668326
Azimuth
10 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
124.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.04”

Context: 2.04

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG016Santas Gloria · leadGrade: 0.35Grade Unit: %Intercept: 2.04 mView all details
Link to this fact

Identity

Hole ID
SG016
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.35
Grade Unit
%
Intercept
2.04 m
From
74.96 m
To
77 m
Hole Depth
78.4 m
Intercept Depth
74.96 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG016:74.96-77

Location

Easting
344742
Northing
8668326
Azimuth
10 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
124.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.35”

Context: 2.04

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG016Santas Gloria · zincGrade: 0.2Grade Unit: %Intercept: 2.04 mView all details
Link to this fact

Identity

Hole ID
SG016
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.2
Grade Unit
%
Intercept
2.04 m
From
74.96 m
To
77 m
Hole Depth
78.4 m
Intercept Depth
74.96 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG016:74.96-77

Location

Easting
344742
Northing
8668326
Azimuth
10 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
124.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.20”

Context: 2.04

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 168.8Grade Unit: g/tIntercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
168.8
Grade Unit
g/t
Intercept
2.3 m
From
165.8 m
To
168.1 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:165.8-168.1

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
195.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This intercept shows good silver grades and indicates continuity of mineralization, with higher-grade zones within.

Positive factors

  • Strong silver grade over a moderate width.
  • Contains higher-grade sub-intervals.

Negative factors

  • True width not determined.

Evidence · table

“168.8”

Context: 2.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.21Grade Unit: g/tIntercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.21
Grade Unit
g/t
Intercept
2.3 m
From
165.8 m
To
168.1 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:165.8-168.1

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
195.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.21”

Context: 2.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.15Grade Unit: %Intercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.15
Grade Unit
%
Intercept
2.3 m
From
165.8 m
To
168.1 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:165.8-168.1

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
195.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.15”

Context: 2.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.28Grade Unit: %Intercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.28
Grade Unit
%
Intercept
2.3 m
From
165.8 m
To
168.1 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:165.8-168.1

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
195.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.28”

Context: 2.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 387.1Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
387.1
Grade Unit
g/t
Intercept
0.8 m
From
166.6 m
To
167.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:166.6-167.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
418.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This sub-interval represents a significant high-grade silver zone within a broader intercept, indicating strong mineralization.

Positive factors

  • Very high-grade silver intercept.

Negative factors

  • Narrow width.
  • True width not determined.

Evidence · table

“387.1”

Context: 0.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.24Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.24
Grade Unit
g/t
Intercept
0.8 m
From
166.6 m
To
167.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:166.6-167.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
418.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.24”

Context: 0.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.25Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.25
Grade Unit
%
Intercept
0.8 m
From
166.6 m
To
167.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:166.6-167.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
418.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.25”

Context: 0.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.29Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.29
Grade Unit
%
Intercept
0.8 m
From
166.6 m
To
167.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:166.6-167.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
418.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.29”

Context: 0.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 164.8Grade Unit: g/tIntercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
164.8
Grade Unit
g/t
Intercept
6.2 m
From
174.7 m
To
180.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:174.7-180.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
190.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This is a material intercept with good silver grades over a substantial width, indicating a robust mineralized zone with very high-grade pockets.

Positive factors

  • Strong silver grade over a significant width.
  • Contains multiple high-grade sub-intervals, including bonanza grades.

Negative factors

  • True width not determined.

Evidence · table

“164.8”

Context: 6.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.2Grade Unit: g/tIntercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
6.2 m
From
174.7 m
To
180.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:174.7-180.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
190.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.20”

Context: 6.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.17Grade Unit: %Intercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.17
Grade Unit
%
Intercept
6.2 m
From
174.7 m
To
180.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:174.7-180.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
190.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.17”

Context: 6.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.23Grade Unit: %Intercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.23
Grade Unit
%
Intercept
6.2 m
From
174.7 m
To
180.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:174.7-180.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
190.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.23”

Context: 6.20

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 238.7Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
238.7
Grade Unit
g/t
Intercept
0.9 m
From
175.9 m
To
176.8 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:175.9-176.8

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
271.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade, contributing to the overall high-grade nature of the broader intercept.

Positive factors

  • High-grade silver intercept.

Negative factors

  • Narrow width.
  • True width not determined.

Evidence · table

“238.7”

Context: 0.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.27Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.27
Grade Unit
g/t
Intercept
0.9 m
From
175.9 m
To
176.8 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:175.9-176.8

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
271.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.27”

Context: 0.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.11Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.11
Grade Unit
%
Intercept
0.9 m
From
175.9 m
To
176.8 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:175.9-176.8

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
271.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.11”

Context: 0.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.35Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.35
Grade Unit
%
Intercept
0.9 m
From
175.9 m
To
176.8 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:175.9-176.8

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
271.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.35”

Context: 0.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 533.8Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
533.8
Grade Unit
g/t
Intercept
0.6 m
From
176.8 m
To
177.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:176.8-177.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
578.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This is a bonanza-grade silver intercept, indicating extremely high-grade mineralization within the system, despite its narrow width.

Positive factors

  • Exceptional bonanza-grade silver intercept.

Negative factors

  • Very narrow width.
  • True width not determined.

Evidence · table

“533.8”

Context: 0.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.32Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.32
Grade Unit
g/t
Intercept
0.6 m
From
176.8 m
To
177.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:176.8-177.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
578.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.32”

Context: 0.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.24Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.24
Grade Unit
%
Intercept
0.6 m
From
176.8 m
To
177.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:176.8-177.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
578.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.24”

Context: 0.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.57Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.57
Grade Unit
%
Intercept
0.6 m
From
176.8 m
To
177.4 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:176.8-177.4

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
578.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Moderate zinc grade, contributing to the overall polymetallic value of the intercept.

Evidence · table

“0.57”

Context: 0.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 256.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
256.1
Grade Unit
g/t
Intercept
0.5 m
From
179.8 m
To
180.3 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:179.8-180.3

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
289.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade, contributing to the overall high-grade nature of the broader intercept.

Positive factors

  • High-grade silver intercept.

Negative factors

  • Very narrow width.
  • True width not determined.

Evidence · table

“256.1”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.16Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
0.5 m
From
179.8 m
To
180.3 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:179.8-180.3

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
289.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.16”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.63Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.63
Grade Unit
%
Intercept
0.5 m
From
179.8 m
To
180.3 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:179.8-180.3

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
289.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Moderate lead grade, contributing to the overall polymetallic value of the intercept.

Evidence · table

“0.63”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.29Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.29
Grade Unit
%
Intercept
0.5 m
From
179.8 m
To
180.3 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:179.8-180.3

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
289.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.29”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · silverGrade: 220.7Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
220.7
Grade Unit
g/t
Intercept
0.7 m
From
193.2 m
To
193.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:193.2-193.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
240.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade, indicating continued mineralization at depth.

Positive factors

  • High-grade silver intercept.

Negative factors

  • Narrow width.
  • True width not determined.

Evidence · table

“220.7”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · goldGrade: 0.1Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
0.7 m
From
193.2 m
To
193.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:193.2-193.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
240.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.10”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · leadGrade: 0.18Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.18
Grade Unit
%
Intercept
0.7 m
From
193.2 m
To
193.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:193.2-193.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
240.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.18”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG017Santas Gloria · zincGrade: 0.35Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG017
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.35
Grade Unit
%
Intercept
0.7 m
From
193.2 m
To
193.9 m
Hole Depth
194.2 m
Intercept Depth
165.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG017:193.2-193.9

Location

Easting
344742
Northing
8668326
Azimuth
320 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
240.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.35”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · silverGrade: 198.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
198.1
Grade Unit
g/t
Intercept
1.1 m
From
87.3 m
To
88.4 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-88.4

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
211.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This intercept shows good silver grades and indicates continuity of mineralization, with higher-grade zones within.

Positive factors

  • Strong silver grade over a narrow width.
  • Contains higher-grade sub-intervals.

Negative factors

  • True width not determined.

Evidence · table

“198.1”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · goldGrade: 0.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
1.1 m
From
87.3 m
To
88.4 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-88.4

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
211.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.10”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · leadGrade: 0.19Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.19
Grade Unit
%
Intercept
1.1 m
From
87.3 m
To
88.4 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-88.4

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
211.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.19”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · zincGrade: 0.4Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.4
Grade Unit
%
Intercept
1.1 m
From
87.3 m
To
88.4 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-88.4

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
211.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.40”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · silverGrade: 321.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
321.6
Grade Unit
g/t
Intercept
0.5 m
From
87.3 m
To
87.8 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-87.8

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
346.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This sub-interval represents a significant high-grade silver zone within a broader intercept, indicating strong mineralization.

Positive factors

  • Very high-grade silver intercept.

Negative factors

  • Very narrow width.
  • True width not determined.

Evidence · table

“321.6”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · goldGrade: 0.08Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.08
Grade Unit
g/t
Intercept
0.5 m
From
87.3 m
To
87.8 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-87.8

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
346.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.08”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · leadGrade: 0.3Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.3
Grade Unit
%
Intercept
0.5 m
From
87.3 m
To
87.8 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-87.8

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
346.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.30”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG018Santas Gloria · zincGrade: 0.5Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG018
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.5
Grade Unit
%
Intercept
0.5 m
From
87.3 m
To
87.8 m
Hole Depth
119.1 m
Intercept Depth
87.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG018:87.3-87.8

Location

Easting
344742
Northing
8668326
Azimuth
40 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
346.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Moderate zinc grade, contributing to the overall polymetallic value of the intercept.

Evidence · table

“0.50”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · silverGrade: 332.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
332.1
Grade Unit
g/t
Intercept
1.1 m
From
109.8 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:109.8-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
350.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This intercept shows very strong silver grades over a narrow width, indicating a significant high-grade zone.

Positive factors

  • Very high-grade silver intercept.
  • Contains higher-grade sub-intervals.

Negative factors

  • True width not determined.

Evidence · table

“332.1”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · goldGrade: 0.11Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
1.1 m
From
109.8 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:109.8-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
350.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.11”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · leadGrade: 0.1Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.1
Grade Unit
%
Intercept
1.1 m
From
109.8 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:109.8-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
350.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.10”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · zincGrade: 0.68Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.68
Grade Unit
%
Intercept
1.1 m
From
109.8 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:109.8-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
350.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Moderate zinc grade, contributing to the overall polymetallic value of the intercept.

Evidence · table

“068”

Context: 1.10

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · silverGrade: 392.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
392.4
Grade Unit
g/t
Intercept
0.5 m
From
110.4 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:110.4-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
443.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This sub-interval represents a significant high-grade silver zone within a broader intercept, indicating strong mineralization.

Positive factors

  • Very high-grade silver intercept.

Negative factors

  • Very narrow width.
  • True width not determined.

Evidence · table

“392.4”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · goldGrade: 0.13Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.13
Grade Unit
g/t
Intercept
0.5 m
From
110.4 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:110.4-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
443.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.13”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · leadGrade: 0.23Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.23
Grade Unit
%
Intercept
0.5 m
From
110.4 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:110.4-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
443.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.23”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG019Santas Gloria · zincGrade: 0.38Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG019
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.38
Grade Unit
%
Intercept
0.5 m
From
110.4 m
To
110.9 m
Hole Depth
113.6 m
Intercept Depth
109.8 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG019:110.4-110.9

Location

Easting
344840
Northing
8668339
Azimuth
50 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
443.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.38”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG020Santas Gloria · silverGrade: 239.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG020
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
239.4
Grade Unit
g/t
Intercept
0.5 m
From
158 m
To
158.5 m
Hole Depth
165.1 m
Intercept Depth
158 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG020:158-158.5

Location

Easting
344840
Northing
8668339
Azimuth
63 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
260.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade, indicating continued mineralization.

Positive factors

  • High-grade silver intercept.

Negative factors

  • Very narrow width.
  • True width not determined.

Evidence · table

“239.4”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG020Santas Gloria · goldGrade: 0.11Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG020
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
0.5 m
From
158 m
To
158.5 m
Hole Depth
165.1 m
Intercept Depth
158 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG020:158-158.5

Location

Easting
344840
Northing
8668339
Azimuth
63 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
260.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.11”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG020Santas Gloria · leadGrade: 0.13Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG020
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.13
Grade Unit
%
Intercept
0.5 m
From
158 m
To
158.5 m
Hole Depth
165.1 m
Intercept Depth
158 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG020:158-158.5

Location

Easting
344840
Northing
8668339
Azimuth
63 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
260.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.13”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG020Santas Gloria · zincGrade: 0.38Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
SG020
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.38
Grade Unit
%
Intercept
0.5 m
From
158 m
To
158.5 m
Hole Depth
165.1 m
Intercept Depth
158 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG020:158-158.5

Location

Easting
344840
Northing
8668339
Azimuth
63 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
260.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.38”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · silverGrade: 248.5Grade Unit: g/tIntercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
248.5
Grade Unit
g/t
Intercept
3.9 m
From
91.9 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:91.9-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
268.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This is a material intercept with high silver grades over a good width, indicating a robust mineralized zone with bonanza-grade pockets.

Positive factors

  • High-grade silver intercept over a good width.
  • Contains bonanza-grade sub-intervals.

Negative factors

  • True width not determined.

Evidence · table

“248.5”

Context: 3.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · goldGrade: 0.12Grade Unit: g/tIntercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.12
Grade Unit
g/t
Intercept
3.9 m
From
91.9 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:91.9-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
268.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.12”

Context: 3.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · leadGrade: 0.32Grade Unit: %Intercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.32
Grade Unit
%
Intercept
3.9 m
From
91.9 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:91.9-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
268.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low lead grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.32”

Context: 3.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · zincGrade: 0.14Grade Unit: %Intercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.14
Grade Unit
%
Intercept
3.9 m
From
91.9 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:91.9-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
268.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.14”

Context: 3.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · silverGrade: 606.2Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
606.2
Grade Unit
g/t
Intercept
0.7 m
From
95.1 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:95.1-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
638.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: This is a bonanza-grade silver intercept, indicating extremely high-grade mineralization within the system, despite its narrow width.

Positive factors

  • Exceptional bonanza-grade silver intercept.

Negative factors

  • Very narrow width.
  • True width not determined.

Evidence · table

“606.2”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · goldGrade: 0.18Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
0.7 m
From
95.1 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:95.1-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
638.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low gold grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.18”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · leadGrade: 0.68Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.68
Grade Unit
%
Intercept
0.7 m
From
95.1 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:95.1-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
638.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Moderate lead grade, contributing to the overall polymetallic value of the intercept.

Evidence · table

“0.68”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

SG022Santas Gloria · zincGrade: 0.12Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
SG022
Project
Santas Gloria
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.12
Grade Unit
%
Intercept
0.7 m
From
95.1 m
To
95.8 m
Hole Depth
98.7 m
Intercept Depth
91.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
SG022:95.1-95.8

Location

Easting
344838
Northing
8668340
Azimuth
44 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Metal Eq. Grade
638.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Low zinc grade, contributing as a minor credit to the overall polymetallic intercept.

Evidence · table

“0.12”

Context: 0.70

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 164.8Grade Unit: g/tIntercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
164.8
Grade Unit
g/t
Intercept
6.2 m
From
174.7 m
To
180.9 m
Intercept Depth
174.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:174.7-180.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 164.8 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1021.8 g/t·m is moderate.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“164.8”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.2Grade Unit: g/tIntercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
6.2 m
From
174.7 m
To
180.9 m
Intercept Depth
174.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:174.7-180.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.2 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.20”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.17Grade Unit: %Intercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.17
Grade Unit
%
Intercept
6.2 m
From
174.7 m
To
180.9 m
Intercept Depth
174.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:174.7-180.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.1 %·m is below.

Negative factors

  • 0.17 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.17”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.23Grade Unit: %Intercept: 6.2 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.23
Grade Unit
%
Intercept
6.2 m
From
174.7 m
To
180.9 m
Intercept Depth
174.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:174.7-180.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.4 %·m is below.

Negative factors

  • 0.23 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.23”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 238.7Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
238.7
Grade Unit
g/t
Intercept
0.9 m
From
175.9 m
To
176.8 m
Intercept Depth
175.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:175.9-176.8

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 238.7 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 214.8 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 238.7 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“238.7”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.27Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.27
Grade Unit
g/t
Intercept
0.9 m
From
175.9 m
To
176.8 m
Intercept Depth
175.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:175.9-176.8

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.27 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.11Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.11
Grade Unit
%
Intercept
0.9 m
From
175.9 m
To
176.8 m
Intercept Depth
175.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:175.9-176.8

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.11 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.35Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.35
Grade Unit
%
Intercept
0.9 m
From
175.9 m
To
176.8 m
Intercept Depth
175.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:175.9-176.8

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.35 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.35”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 533.8Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
533.8
Grade Unit
g/t
Intercept
0.6 m
From
176.8 m
To
177.4 m
Intercept Depth
176.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:176.8-177.4

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 533.8 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 320.3 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 533.8 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“533.8”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.32Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.32
Grade Unit
g/t
Intercept
0.6 m
From
176.8 m
To
177.4 m
Intercept Depth
176.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:176.8-177.4

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.32”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.24Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.24
Grade Unit
%
Intercept
0.6 m
From
176.8 m
To
177.4 m
Intercept Depth
176.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:176.8-177.4

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.24 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.24”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.57Grade Unit: %Intercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.57
Grade Unit
%
Intercept
0.6 m
From
176.8 m
To
177.4 m
Intercept Depth
176.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:176.8-177.4

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.57 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.57”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 256.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
256.1
Grade Unit
g/t
Intercept
0.5 m
From
179.8 m
To
180.3 m
Intercept Depth
179.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:179.8-180.3

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 256.1 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 128.1 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 256.1 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“256.1”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.16Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
0.5 m
From
179.8 m
To
180.3 m
Intercept Depth
179.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:179.8-180.3

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.16 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.63Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.63
Grade Unit
%
Intercept
0.5 m
From
179.8 m
To
180.3 m
Intercept Depth
179.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:179.8-180.3

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.63 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.63 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.63”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.29Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.29
Grade Unit
%
Intercept
0.5 m
From
179.8 m
To
180.3 m
Intercept Depth
179.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:179.8-180.3

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.29 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.29”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · silverGrade: 220.7Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
silver
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
220.7
Grade Unit
g/t
Intercept
0.7 m
From
193.2 m
To
193.9 m
Intercept Depth
193.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:193.2-193.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 220.7 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 154.5 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 220.7 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“220.7”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · goldGrade: 0.1Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
gold
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
0.7 m
From
193.2 m
To
193.9 m
Intercept Depth
193.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:193.2-193.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · leadGrade: 0.18Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
lead
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.18
Grade Unit
%
Intercept
0.7 m
From
193.2 m
To
193.9 m
Intercept Depth
193.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:193.2-193.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.18 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.18”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Andmineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal · zincGrade: 0.35Grade Unit: %Intercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
And
Project
mineralogy and alteration confirms that drill holes intercepted the uppermost parts of an intermediate sulphidation epithermal
Commodity
zinc
Region
peru
Reported Region
peru
Ticker
FAS

Geometry

Grade
0.35
Grade Unit
%
Intercept
0.7 m
From
193.2 m
To
193.9 m
Intercept Depth
193.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
And:193.2-193.9

QA/QC

Laboratory
AHK Group
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.35 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.35”

Context: And

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.