Global Battery Metals Announces Initial Knockeen Dike Swarm Assay Results from Leinster Lithium Project, Ireland
Original announcement by tmx on
- Company
- Global Battery Metals Ltd.
- Ticker
- GBML
- Exchange
- TSX
- Region
- Ireland
- Primary commodity
- Lithium
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-09-12 07:40:27 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Global Battery Metals announced initial assay results from its first phase of drilling at the Knockeen Dike Swarm within the Leinster Lithium Project in Ireland. All nine holes intersected lithium-bearing pegmatites, confirming a new LCT pegmatite system with grades up to 2.57% Li2O. The program recorded 24 lithium-bearing intervals, with true widths ranging from 0.03m to 0.48m, indicating a significant new discovery in an undrilled area.
Reasoning: Initial exploration drilling successfully confirmed a new lithium pegmatite system with multiple high-grade intercepts, including an exceptional 2.57% Li2O, in a previously undrilled area, although the true widths are narrow.
Positive factors
- New bedrock LCT pegmatite system confirmed
- High-grade lithium intercepts up to 2.57% Li2O
- Multiple lithium-bearing pegmatite intersections across all holes
- True widths reported for all intercepts
- QA/QC procedures disclosed
Negative factors
- Intercepts are generally narrow
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 33
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Intercept 15 in Hole 23-1597-06 reported 2.57% Li2O, which exceeds the 1.8% Li2O exceptional threshold for lithium.
Evidence · text
“highest values grading up to 2.57% Li 2 O in Intercept 15 in Hole 23-1597-06”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document explicitly provides a 'TRUE THICKNESS' column in the table of results for all intersected intervals.
Evidence · table
“TRUE THICKNESS”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The drilling confirmed a 'new bedrock LCT pegmatite system' in a 'brand-new area' with 'no historical drilling', indicating an extension or discovery.
Evidence · text
“Drilling Confirms New Bedrock LCT Pegmatite System”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details a 'tightly controlled chain of custody and rigid QA/QC sampling process which included regular insertion of certified reference materials including standards, blanks and sample duplicates'.
Evidence · text
“tightly controlled chain of custody and rigid QA/QC sampling process which included regular insertion of certified reference materials including standards, blanks and sample duplicates”
Extracted facts
Stored fact records: 33. Some facts used in scoring do not have a stored record.
Drill Results (33)
23-1597-01Leinster · lithiumGrade: 0.22Grade Unit: %Intercept: 0.43 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.22
- Grade Unit
- %
- Intercept
- 0.43 m
- True Width
- 0.06 m
- From
- 33.26 m
- To
- 33.69 m
- Intercept Depth
- 33.26 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:33.26-33.69
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.22”
Context: 0.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.06
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 0.35Grade Unit: %Intercept: 0.24 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 0.24 m
- True Width
- 0.03 m
- From
- 33.69 m
- To
- 33.93 m
- Intercept Depth
- 33.69 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:33.69-33.93
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.35”
Context: 0.24
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.03
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 0.95Grade Unit: %Intercept: 0.27 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.95
- Grade Unit
- %
- Intercept
- 0.27 m
- True Width
- 0.04 m
- From
- 33.93 m
- To
- 34.2 m
- Intercept Depth
- 33.93 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:33.93-34.2
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.95”
Context: 0.27
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 1.43Grade Unit: %Intercept: 0.39 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.43
- Grade Unit
- %
- Intercept
- 0.39 m
- True Width
- 0.05 m
- From
- 34.2 m
- To
- 34.59 m
- Intercept Depth
- 34.2 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:34.2-34.59
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Strong-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Strong-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.43”
Context: 0.39
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.05
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 2.95Grade Unit: %Intercept: 0.36 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 2.95
- Grade Unit
- %
- Intercept
- 0.36 m
- True Width
- 0.05 m
- From
- 34.59 m
- To
- 34.95 m
- Intercept Depth
- 34.59 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:34.59-34.95
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Exceptional-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Exceptional-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“2.95”
Context: 0.36
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.05
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 0.72Grade Unit: %Intercept: 0.64 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.72
- Grade Unit
- %
- Intercept
- 0.64 m
- True Width
- 0.09 m
- From
- 34.95 m
- To
- 35.59 m
- Intercept Depth
- 34.95 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:34.95-35.59
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Weak-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Weak-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.72”
Context: 0.64
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.09
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 0.97Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.97
- Grade Unit
- %
- Intercept
- 0.2 m
- True Width
- 0.03 m
- From
- 35.59 m
- To
- 35.79 m
- Intercept Depth
- 35.59 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:35.59-35.79
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.97”
Context: 0.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.03
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-01Leinster · lithiumGrade: 0.39Grade Unit: %Intercept: 0.26 mView all detailsHide details
Identity
- Hole ID
- 23-1597-01
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 0.26 m
- True Width
- 0.04 m
- From
- 35.79 m
- To
- 36.05 m
- Intercept Depth
- 35.79 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-01:35.79-36.05
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.39”
Context: 0.26
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-02Leinster · lithiumGrade: 0.18Grade Unit: %Intercept: 0.36 mView all detailsHide details
Identity
- Hole ID
- 23-1597-02
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.18
- Grade Unit
- %
- Intercept
- 0.36 m
- True Width
- 0.36 m
- From
- 19.65 m
- To
- 20.01 m
- Intercept Depth
- 19.65 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-02:19.65-20.01
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.18”
Context: 0.36
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.36
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-02Leinster · lithiumGrade: 1.52Grade Unit: %Intercept: 0.28 mView all detailsHide details
Identity
- Hole ID
- 23-1597-02
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.52
- Grade Unit
- %
- Intercept
- 0.28 m
- True Width
- 0.27 m
- From
- 23.33 m
- To
- 23.61 m
- Intercept Depth
- 23.33 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-02:23.33-23.61
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Strong-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Strong-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.52”
Context: 0.28
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.27
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-02Leinster · lithiumGrade: 1.59Grade Unit: %Intercept: 0.39 mView all detailsHide details
Identity
- Hole ID
- 23-1597-02
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.59
- Grade Unit
- %
- Intercept
- 0.39 m
- True Width
- 0.39 m
- From
- 31.46 m
- To
- 31.85 m
- Intercept Depth
- 31.46 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-02:31.46-31.85
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Strong-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Strong-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.59”
Context: 0.39
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.39
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-02Leinster · lithiumGrade: 0.2Grade Unit: %Intercept: 0.26 mView all detailsHide details
Identity
- Hole ID
- 23-1597-02
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 0.26 m
- True Width
- 0.14 m
- From
- 81.14 m
- To
- 81.4 m
- Intercept Depth
- 81.14 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-02:81.14-81.4
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.20”
Context: 0.26
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.14
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-03Leinster · lithiumGrade: 0.16Grade Unit: %Intercept: 0.22 mView all detailsHide details
Identity
- Hole ID
- 23-1597-03
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.16
- Grade Unit
- %
- Intercept
- 0.22 m
- True Width
- 0.22 m
- From
- 20.93 m
- To
- 21.15 m
- Intercept Depth
- 20.93 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-03:20.93-21.15
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.16”
Context: 0.22
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.22
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-03Leinster · lithiumGrade: 0.79Grade Unit: %Intercept: 0.09 mView all detailsHide details
Identity
- Hole ID
- 23-1597-03
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.79
- Grade Unit
- %
- Intercept
- 0.09 m
- True Width
- 0.09 m
- From
- 46.94 m
- To
- 47.03 m
- Intercept Depth
- 46.94 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-03:46.94-47.03
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Weak-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- Weak-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.79”
Context: 0.09
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.09
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-03Leinster · lithiumGrade: 0.13Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- 23-1597-03
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 0.5 m
- True Width
- 0.48 m
- From
- 47.03 m
- To
- 47.53 m
- Intercept Depth
- 47.03 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-03:47.03-47.53
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.13”
Context: 0.50
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.48
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-03Leinster · lithiumGrade: 0.65Grade Unit: %Intercept: 0.06 mView all detailsHide details
Identity
- Hole ID
- 23-1597-03
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.65
- Grade Unit
- %
- Intercept
- 0.06 m
- True Width
- 0.06 m
- From
- 47.53 m
- To
- 47.59 m
- Intercept Depth
- 47.53 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-03:47.53-47.59
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Weak-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- Weak-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.65”
Context: 0.06
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.06
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-03Leinster · lithiumGrade: 0.57Grade Unit: %Intercept: 0.27 mView all detailsHide details
Identity
- Hole ID
- 23-1597-03
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.57
- Grade Unit
- %
- Intercept
- 0.27 m
- True Width
- 0.23 m
- From
- 68.33 m
- To
- 68.6 m
- Intercept Depth
- 68.33 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-03:68.33-68.6
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.57”
Context: 0.27
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-03Leinster · lithiumGrade: 0.96Grade Unit: %Intercept: 0.2 mView all detailsHide details
Identity
- Hole ID
- 23-1597-03
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.96
- Grade Unit
- %
- Intercept
- 0.2 m
- True Width
- 0.18 m
- From
- 77.96 m
- To
- 78.16 m
- Intercept Depth
- 77.96 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-03:77.96-78.16
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.96”
Context: 0.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.18
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-04Leinster · lithiumGrade: 0.59Grade Unit: %Intercept: 0.35 mView all detailsHide details
Identity
- Hole ID
- 23-1597-04
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 0.35 m
- True Width
- 0.34 m
- From
- 83.39 m
- To
- 83.74 m
- Intercept Depth
- 83.39 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-04:83.39-83.74
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.59”
Context: 0.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.34
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-04Leinster · lithiumGrade: 0.37Grade Unit: %Intercept: 0.15 mView all detailsHide details
Identity
- Hole ID
- 23-1597-04
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.37
- Grade Unit
- %
- Intercept
- 0.15 m
- True Width
- 0.15 m
- From
- 125.01 m
- To
- 125.16 m
- Intercept Depth
- 125.01 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-04:125.01-125.16
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.37”
Context: 0.15
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.15
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-05Leinster · lithiumGrade: 0.12Grade Unit: %Intercept: 0.17 mView all detailsHide details
Identity
- Hole ID
- 23-1597-05
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 0.17 m
- True Width
- 0.13 m
- From
- 35.05 m
- To
- 35.22 m
- Intercept Depth
- 35.05 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-05:35.05-35.22
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.12”
Context: 0.17
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.13
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-06Leinster · lithiumGrade: 1.14Grade Unit: %Intercept: 0.32 mView all detailsHide details
Identity
- Hole ID
- 23-1597-06
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.14
- Grade Unit
- %
- Intercept
- 0.32 m
- True Width
- 0.17 m
- From
- 42.57 m
- To
- 42.89 m
- Intercept Depth
- 42.57 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-06:42.57-42.89
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.14”
Context: 0.32
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.17
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-06Leinster · lithiumGrade: 1.12Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- 23-1597-06
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.12
- Grade Unit
- %
- Intercept
- 0.37 m
- True Width
- 0.23 m
- From
- 44.28 m
- To
- 44.65 m
- Intercept Depth
- 44.28 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-06:44.28-44.65
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.12”
Context: 0.37
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-06Leinster · lithiumGrade: 2.57Grade Unit: %Intercept: 0.18 mView all detailsHide details
Identity
- Hole ID
- 23-1597-06
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 2.57
- Grade Unit
- %
- Intercept
- 0.18 m
- True Width
- 0.14 m
- From
- 64.12 m
- To
- 64.3 m
- Intercept Depth
- 64.12 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-06:64.12-64.3
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Exceptional-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Exceptional-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“2.57”
Context: 0.18
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.14
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-07Leinster · lithiumGrade: 1.26Grade Unit: %Intercept: 0.29 mView all detailsHide details
Identity
- Hole ID
- 23-1597-07
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.26
- Grade Unit
- %
- Intercept
- 0.29 m
- True Width
- 0.24 m
- From
- 56.55 m
- To
- 56.84 m
- Intercept Depth
- 56.55 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-07:56.55-56.84
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.26”
Context: 0.29
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.24
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-07Leinster · lithiumGrade: 0.26Grade Unit: %Intercept: 0.14 mView all detailsHide details
Identity
- Hole ID
- 23-1597-07
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 0.14 m
- True Width
- 0.12 m
- From
- 69.63 m
- To
- 69.77 m
- Intercept Depth
- 69.63 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-07:69.63-69.77
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.26”
Context: 0.14
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.12
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-07Leinster · lithiumGrade: 0.62Grade Unit: %Intercept: 0.33 mView all detailsHide details
Identity
- Hole ID
- 23-1597-07
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.62
- Grade Unit
- %
- Intercept
- 0.33 m
- True Width
- 0.24 m
- From
- 72.24 m
- To
- 72.55 m
- Intercept Depth
- 72.24 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-07:72.24-72.55
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Weak-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Weak-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.62”
Context: 0.33
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.24
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-07Leinster · lithiumGrade: 0.32Grade Unit: %Intercept: 0.1 mView all detailsHide details
Identity
- Hole ID
- 23-1597-07
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 0.1 m
- True Width
- 0.08 m
- From
- 107.49 m
- To
- 107.58 m
- Intercept Depth
- 107.49 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-07:107.49-107.58
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.32”
Context: 0.10
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.08
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-08Leinster · lithiumGrade: 0.35Grade Unit: %Intercept: 1.11 mView all detailsHide details
Identity
- Hole ID
- 23-1597-08
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 1.11 m
- True Width
- 0.12 m
- From
- 68.58 m
- To
- 69.69 m
- Intercept Depth
- 68.58 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-08:68.58-69.69
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.35”
Context: 1.11
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.12
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-09Leinster · lithiumGrade: 0.62Grade Unit: %Intercept: 0.18 mView all detailsHide details
Identity
- Hole ID
- 23-1597-09
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.62
- Grade Unit
- %
- Intercept
- 0.18 m
- True Width
- 0.12 m
- From
- 33.81 m
- To
- 33.99 m
- Intercept Depth
- 33.81 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-09:33.81-33.99
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Weak-grade lithium intercept in initial drilling of a new area, with true width disclosed but very narrow.
Positive factors
- Weak-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.62”
Context: 0.18
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.12
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-09Leinster · lithiumGrade: 0.53Grade Unit: %Intercept: 0.36 mView all detailsHide details
Identity
- Hole ID
- 23-1597-09
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.53
- Grade Unit
- %
- Intercept
- 0.36 m
- True Width
- 0.26 m
- From
- 42.34 m
- To
- 42.7 m
- Intercept Depth
- 42.34 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-09:42.34-42.7
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Low-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
- Low grade for lithium
Evidence · table
“0.53”
Context: 0.36
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.26
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-09Leinster · lithiumGrade: 1.18Grade Unit: %Intercept: 0.41 mView all detailsHide details
Identity
- Hole ID
- 23-1597-09
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 1.18
- Grade Unit
- %
- Intercept
- 0.41 m
- True Width
- 0.25 m
- From
- 65.73 m
- To
- 66.14 m
- Intercept Depth
- 65.73 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-09:65.73-66.14
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Moderate-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Moderate-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“1.18”
Context: 0.41
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.25
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
23-1597-09Leinster · lithiumGrade: 0.74Grade Unit: %Intercept: 0.39 mView all detailsHide details
Identity
- Hole ID
- 23-1597-09
- Project
- Leinster
- Commodity
- lithium
- Region
- ireland
- Reported Region
- ireland
- Ticker
- GBML
Geometry
- Grade
- 0.74
- Grade Unit
- %
- Intercept
- 0.39 m
- True Width
- 0.22 m
- From
- 78.17 m
- To
- 78.56 m
- Intercept Depth
- 78.17 m
Classification
- Program
- exploration
- Sample Type
- drill
- Group ID
- 23-1597-09:78.17-78.56
QA/QC
- Laboratory
- ALS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2023-11-15T00:00:00.000Z
Reasoning: Weak-grade lithium intercept in initial drilling of a new area, with true width disclosed but narrow.
Positive factors
- Weak-grade lithium intercept
- True width disclosed
- New discovery area
Negative factors
- Narrow intercept width
Evidence · table
“0.74”
Context: 0.39
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.22
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.