# Green Bridge Metals Intersects 195.0 Metres Grading 0.25% Cu and 10.18% TiO2 at Titac South, Minnesota; Step-Out Hole Confirms Mineralization at Previously Untested Geophysical Target

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234

Original source: https://www.accessnewswire.com/newsroom/en/metals-and-mining/green-bridge-metals-intersects-195.0-metres-grading-0.25-cu-and-10.18-tio2-at-tit-1219004

Publisher: accesswire

Original announcement: 2026-09-11T23:56:23.932Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Green Bridge Metals Corporation

- Ticker: GRBM

- Exchange: Unavailable

- Region: Minnesota

- Primary commodity: Copper

- Secondary commodities: Titanium, Vanadium, Pge

- Document categories: Drill results

- Extracted: 2026-09-12 00:08:22 UTC

Narrative sentiment: 0.70 · Bullish

## Minestarters Atlas summary

Green Bridge Metals reported final assay results from its Phase 1 diamond drill program at the Titac Project in Minnesota. Hole TS26-004a intersected a significant 195.0m grading 0.25% Cu and 10.18% TiO₂, confirming existing mineralization. An exploratory step-out hole, TS26-007, successfully intersected mineralization at a previously untested geophysical target, validating the company's 3D VTEM inversion modelling as an effective targeting tool.

Reasoning: The drill results confirm broad zones of copper and titanium mineralization, with a successful step-out hole validating the exploration model and opening new targets, leading to accelerated future programs.

- Positive factor: Significant long intercepts of copper and titanium dioxide mineralization

- Positive factor: Successful step-out drilling confirming mineralization at a new geophysical target

- Positive factor: Validation of 3D VTEM inversion modelling as an effective targeting tool

- Positive factor: Increased confidence in geological model and acceleration of Phase 2 drilling

- Negative factor: True widths cannot be determined with confidence due to irregular geometry

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 56

## Classification and evidence

**Step-Out Extension**

Polarity: positive

Definition: Mineralization extended beyond the previously known limit.

Why it applies: Exploratory drill hole TS26-007 tested a previously untested geophysical target and successfully intersected mineralization, extending the known mineralized footprint.

Evidence · text

> Exploratory step-out hole TS26-007, testing a previously untested geophysical target, returned 12.0 m @ 0.20% Cu, 8.33% TiO₂, 0.15% V₂O₅, intersecting mineralization associated with the geophysical anomaly.

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: The release includes a dedicated 'Quality Assurance and Quality Control' section detailing sample collection, laboratory used \(Activation Laboratories Ltd.\), and analytical methods.

Evidence · text

> Quality Assurance and Quality Control Green Bridge Metals exploration samples were collected in accordance with industry standards and best practices. All samples were submitted to Activation Laboratories Ltd. in Thunder Bay, Ontario, for geochemical analysis.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that all reported intervals are downhole lengths and true widths cannot currently be determined with confidence due to irregular geometry.

Evidence · text

> All reported intervals are downhole lengths. True widths cannot currently be determined with confidence because of the irregular geometry of the mineralized zones.

## Extracted facts

Stored fact records: 56. Some facts used in scoring do not have a stored record.

## Drill Results (56)

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-0)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept of copper mineralization was reported, though at a low grade, contributing to the overall understanding of the system.

- Positive factor: Very long intercept length

- Negative factor: Low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.08

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-1)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 4.53
- Grade Unit: %
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept of moderate-grade titanium mineralization was reported, indicating broad distribution within the system.

- Positive factor: Very long intercept length

- Positive factor: Moderate titanium grade

- Negative factor: Apparent width only

Evidence · table

> 4.53

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-2)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 1.34
- Grade Unit: %
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept with a notable vanadium grade was reported, adding to the polymetallic potential of the system.

- Positive factor: Very long intercept length

- Positive factor: Significant vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 1.34

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-3)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 14.1
- Grade Unit: ppb
- Intercept: 272.8 m
- From: 26.2 m
- To: 299 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-299
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept showed trace PGE values, indicating its presence but not at economically significant levels for this interval.

- Positive factor: Very long intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 14.1

Context: 272.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-4)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept of low-grade copper was reported, contributing to the overall mineralization profile.

- Positive factor: Moderate intercept length

- Negative factor: Low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.13

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-5)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 5.89
- Grade Unit: %
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept of moderate-grade titanium was reported, indicating consistent mineralization.

- Positive factor: Moderate intercept length

- Positive factor: Moderate titanium grade

- Negative factor: Apparent width only

Evidence · table

> 5.89

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-6)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed low vanadium grades, indicating its presence but not at significant levels for this interval.

- Positive factor: Moderate intercept length

- Negative factor: Low vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.06

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-7)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 15
- Grade Unit: ppb
- Intercept: 34.8 m
- From: 26.2 m
- To: 61 m
- Intercept Depth: 26.2 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:26.2-61
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed trace PGE values, indicating its presence but not at economically significant levels for this interval.

- Positive factor: Moderate intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 15.0

Context: 34.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-8)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept of low-grade copper was reported, contributing to the overall mineralization profile.

- Positive factor: Long intercept length

- Negative factor: Low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.14

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-9)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 7.54
- Grade Unit: %
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept of good-grade titanium was reported, indicating significant titanium mineralization.

- Positive factor: Long intercept length

- Positive factor: Good titanium grade

- Negative factor: Apparent width only

Evidence · table

> 7.54

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-10)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept showed low vanadium grades, indicating its presence but not at significant levels for this interval.

- Positive factor: Long intercept length

- Negative factor: Low vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.09

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-11)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 18.7
- Grade Unit: ppb
- Intercept: 70 m
- From: 203 m
- To: 273 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-273
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept showed trace PGE values, indicating its presence but not at economically significant levels for this interval.

- Positive factor: Long intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 18.7

Context: 70.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-12)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed a moderate copper grade, indicating a higher-grade zone within the broader mineralization.

- Positive factor: Moderate copper grade

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.25

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-13)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 11.23
- Grade Unit: %
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed a high titanium grade, indicating a significant concentration within the broader mineralization.

- Positive factor: High titanium grade

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 11.23

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-14)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed a moderate vanadium grade, contributing to the polymetallic nature of the higher-grade zone.

- Positive factor: Moderate vanadium grade

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.11

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-15)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 20.8
- Grade Unit: ppb
- Intercept: 8 m
- From: 203 m
- To: 211 m
- Intercept Depth: 203 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:203-211
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed trace PGE values, indicating its presence but not at economically significant levels.

- Negative factor: Narrow intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 20.8

Context: 8.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-16)

Titac South · copper

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 237 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a low copper grade, contributing to the overall mineralization profile.

- Positive factor: Moderate intercept length

- Negative factor: Low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.19

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-17)

Titac South · titanium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 6.17
- Grade Unit: %
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 237 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a moderate titanium grade, indicating consistent mineralization.

- Positive factor: Moderate intercept length

- Positive factor: Moderate titanium grade

- Negative factor: Apparent width only

Evidence · table

> 6.17

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-18)

Titac South · vanadium

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 237 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed low vanadium grades, indicating its presence but not at significant levels.

- Positive factor: Moderate intercept length

- Negative factor: Low vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.08

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-19)

Titac South · pge

#### Identity

- Hole ID: TS26-001
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 21.5
- Grade Unit: ppb
- Intercept: 20 m
- From: 237 m
- To: 257 m
- Intercept Depth: 237 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-001:237-257
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed trace PGE values, indicating its presence but not at economically significant levels.

- Positive factor: Moderate intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 21.5

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-20)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept of moderate-grade copper was reported, indicating significant and broad copper mineralization.

- Positive factor: Very long intercept length

- Positive factor: Moderate copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.23

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-21)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 10.28
- Grade Unit: %
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept of high-grade titanium was reported, indicating significant and broad titanium mineralization.

- Positive factor: Very long intercept length

- Positive factor: High titanium grade

- Negative factor: Apparent width only

Evidence · table

> 10.28

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-22)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept showed moderate vanadium grades, contributing to the polymetallic potential of the system.

- Positive factor: Very long intercept length

- Positive factor: Moderate vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.10

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-23)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 22.1
- Grade Unit: ppb
- Intercept: 267 m
- From: 35 m
- To: 302 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-302
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept showed trace PGE values, indicating its presence but not at economically significant levels for this interval.

- Positive factor: Very long intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 22.1

Context: 267.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-24)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a good copper grade, indicating a higher-grade zone within the broader mineralization.

- Positive factor: Moderate copper grade

- Positive factor: Moderate intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.32

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-25)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 10.92
- Grade Unit: %
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a high titanium grade, indicating a significant concentration within the broader mineralization.

- Positive factor: High titanium grade

- Positive factor: Moderate intercept length

- Negative factor: Apparent width only

Evidence · table

> 10.92

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-26)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a moderate vanadium grade, contributing to the polymetallic nature of the higher-grade zone.

- Positive factor: Moderate vanadium grade

- Positive factor: Moderate intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.11

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-27)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 107
- Grade Unit: ppb
- Intercept: 24 m
- From: 35 m
- To: 59 m
- Intercept Depth: 35 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:35-59
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a moderate PGE grade, indicating a more enriched zone for PGEs.

- Positive factor: Moderate PGE grade

- Positive factor: Moderate intercept length

- Negative factor: Apparent width only

Evidence · table

> 107.0

Context: 24.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-28)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 65 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept of moderate-grade copper was reported, indicating significant and broad copper mineralization.

- Positive factor: Very long intercept length

- Positive factor: Moderate copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.25

Context: 195.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-29)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 10.18
- Grade Unit: %
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 65 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept of high-grade titanium was reported, indicating significant and broad titanium mineralization.

- Positive factor: Very long intercept length

- Positive factor: High titanium grade

- Negative factor: Apparent width only

Evidence · table

> 10.18

Context: 195.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-30)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 65 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept showed moderate vanadium grades, contributing to the polymetallic potential of the system.

- Positive factor: Very long intercept length

- Positive factor: Moderate vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.09

Context: 195.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-31)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 13.9
- Grade Unit: ppb
- Intercept: 195 m
- From: 65 m
- To: 261 m
- Intercept Depth: 65 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:65-261
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A very long intercept showed trace PGE values, indicating its presence but not at economically significant levels for this interval.

- Positive factor: Very long intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 13.9

Context: 195.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-32)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 127 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept of moderate-grade copper was reported, indicating a significant zone of copper mineralization.

- Positive factor: Long intercept length

- Positive factor: Moderate copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.29

Context: 62.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-33)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 10.54
- Grade Unit: %
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 127 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept of high-grade titanium was reported, indicating a significant zone of titanium mineralization.

- Positive factor: Long intercept length

- Positive factor: High titanium grade

- Negative factor: Apparent width only

Evidence · table

> 10.54

Context: 62.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-34)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 127 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept showed moderate vanadium grades, contributing to the polymetallic potential of this zone.

- Positive factor: Long intercept length

- Positive factor: Moderate vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.09

Context: 62.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-35)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 13.9
- Grade Unit: ppb
- Intercept: 62 m
- From: 127 m
- To: 189 m
- Intercept Depth: 127 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:127-189
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A long intercept showed trace PGE values, indicating its presence but not at economically significant levels for this interval.

- Positive factor: Long intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 13.9

Context: 62.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-36)

Titac South · copper

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 271 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a low copper grade, contributing to the overall mineralization profile.

- Positive factor: Moderate intercept length

- Negative factor: Low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.18

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-37)

Titac South · titanium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 12.55
- Grade Unit: %
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 271 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a high titanium grade, indicating a significant concentration within the broader mineralization.

- Positive factor: Moderate intercept length

- Positive factor: High titanium grade

- Negative factor: Apparent width only

Evidence · table

> 12.55

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-38)

Titac South · vanadium

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 271 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed a moderate vanadium grade, contributing to the polymetallic nature of this zone.

- Positive factor: Moderate intercept length

- Positive factor: Moderate vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.14

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-004a

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-39)

Titac South · pge

#### Identity

- Hole ID: TS26-004a
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 11.4
- Grade Unit: ppb
- Intercept: 20 m
- From: 271 m
- To: 291 m
- Intercept Depth: 271 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-004a:271-291
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A moderate length intercept showed trace PGE values, indicating its presence but not at economically significant levels.

- Positive factor: Moderate intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 11.4

Context: 20.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-40)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: An extremely long intercept of very low-grade copper was reported in a successful step-out hole, confirming the presence of mineralization at a new target.

- Positive factor: Extremely long intercept length

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Very low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.06

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-41)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 3.4
- Grade Unit: %
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: An extremely long intercept of moderate-grade titanium was reported in a successful step-out hole, confirming the presence of mineralization at a new target.

- Positive factor: Extremely long intercept length

- Positive factor: Moderate titanium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Apparent width only

Evidence · table

> 3.40

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-42)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: An extremely long intercept showed low vanadium grades in a successful step-out hole, confirming its presence at a new target.

- Positive factor: Extremely long intercept length

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Low vanadium grade

- Negative factor: Apparent width only

Evidence · table

> 0.06

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-43)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 12.6
- Grade Unit: ppb
- Intercept: 362 m
- From: 20 m
- To: 382 m
- Intercept Depth: 20 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:20-382
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: An extremely long intercept showed trace PGE values in a successful step-out hole, confirming its presence at a new target.

- Positive factor: Extremely long intercept length

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 12.6

Context: 362.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-44)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 234 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of low-grade copper was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Low copper grade

- Negative factor: Apparent width only

Evidence · table

> 0.10

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-45)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 5.92
- Grade Unit: %
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 234 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade titanium was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate titanium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 5.92

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-46)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 234 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade vanadium was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate vanadium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.16

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-47)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 9.6
- Grade Unit: ppb
- Intercept: 10 m
- From: 234 m
- To: 244 m
- Intercept Depth: 234 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:234-244
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed trace PGE values in a successful step-out hole, confirming its presence at a new target.

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 9.6

Context: 10.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-48)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade copper was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate copper grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.20

Context: 12.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-49)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 8.33
- Grade Unit: %
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of good-grade titanium was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Good titanium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 8.33

Context: 12.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-50)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade vanadium was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate vanadium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.15

Context: 12.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-51)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 17.7
- Grade Unit: ppb
- Intercept: 12 m
- From: 252 m
- To: 264 m
- Intercept Depth: 252 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:252-264
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed trace PGE values in a successful step-out hole, confirming its presence at a new target.

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 17.7

Context: 12.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-52)

Titac South · copper

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: copper
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 284 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade copper was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate copper grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.17

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-53)

Titac South · titanium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: titanium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 6.19
- Grade Unit: %
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 284 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade titanium was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate titanium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 6.19

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-54)

Titac South · vanadium

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: vanadium
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 284 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept of moderate-grade vanadium was reported in a successful step-out hole, confirming mineralization at a new target.

- Positive factor: Moderate vanadium grade

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Apparent width only

Evidence · table

> 0.10

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### TS26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/green-bridge-metals-intersects-195-0-metres-grading-0-25-cu-and-10-18-tio2-at-ti--86cad140-e3f6-4843-a62f-421bc9263234#fact-drill-facts-55)

Titac South · pge

#### Identity

- Hole ID: TS26-007
- Project: Titac South
- Commodity: pge
- Region: minnesota
- Reported Region: minnesota
- Ticker: GRBM

#### Geometry

- Grade: 23.2
- Grade Unit: ppb
- Intercept: 16 m
- From: 284 m
- To: 300 m
- Intercept Depth: 284 m

#### Classification

- Program: exploration
- Sample Type: drill
- Group ID: TS26-007:284-300
- Mining Method: unknown

#### QA/QC

- Laboratory: Activation Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-11T00:00:00.000Z

Reasoning: A narrow intercept showed trace PGE values in a successful step-out hole, confirming its presence at a new target.

- Positive factor: Step-out hole confirming mineralization at new target

- Negative factor: Narrow intercept length

- Negative factor: Low PGE grade

- Negative factor: Apparent width only

Evidence · table

> 23.2

Context: 16.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
