# GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of 4.15% Copper Equivalent

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d

Original source: https://money.tmx.com/en/quote/GRL/news/7669876674970981/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend-

Publisher: tmx

Original announcement: 2025-09-22T11:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: GreenLight Metals Inc.

- Ticker: GRL

- Exchange: TSX

- Region: Wisconsin

- Primary commodity: Copper

- Secondary commodities: Gold, Silver, Tellurium

- Document categories: Drill results

- Extracted: 2026-09-16 03:16:08 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

GreenLight Metals announced significant copper-rich VMS mineralization at its Bend Project in Wisconsin, with initial assay results from the first three holes of its Phase 1 drill program. Hole B25-003 intersected 12.85m grading 4.15% copper equivalent, including high-grade sub-intervals. The program successfully extended mineralization eastward and at depth, with visual observations in the remaining three holes suggesting continued success, though assays are pending.

Reasoning: GreenLight Metals' initial Phase 1 drill results at the Bend Project are highly positive, with a significant copper-rich VMS intercept in B25-003 \(12.85m at 4.15% CuEq\) that extends mineralization. The disclosure of true widths and robust QA/QC enhances confidence, while visual observations in pending holes suggest further strong results. However, pending assays, opaque metal equivalent assumptions, and tellurium overlimit issues introduce some uncertainty.

- Positive factor: High-grade copper equivalent intercept in B25-003 significantly exceeds the 75th percentile for VMS copper deposits.

- Positive factor: Drilling successfully extended mineralization eastward and at depth, confirming the project's growth potential.

- Positive factor: True thickness was disclosed for all reported intercepts, providing clarity on the geometry.

- Positive factor: Visual observations of thick massive to semi-massive sulfides in pending holes B25-004 to B25-006 suggest further strong results.

- Positive factor: Comprehensive QA/QC procedures were disclosed, including certified lab and QP sign-off.

- Positive factor: Tellurium, a critical mineral, is present and could add significant value to the project.

- Negative factor: Assays are pending for three holes \(B25-004 to B25-006\) which currently rely on visual estimates.

- Negative factor: Metal equivalent calculations do not account for metallurgical recoveries or payable metals, reducing transparency.

- Negative factor: Tellurium grades for some samples in B25-003 were calculated using a detection limit \(500 g/t\) due to overlimit analyses, potentially understating the true grade.

Facts used in scoring: 28

## Classification and evidence

**Bonanza Intercept**

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The intercept in B25-003 of 12.85m at 4.15% CuEq is exceptional, significantly exceeding the 75th percentile for VMS copper deposits \(1.4% Cu\).

Evidence · text

> 12.85m of 4.15% Copper Equivalent

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The document explicitly states the true thickness for all reported intercepts, such as '12.85m \(11.3m true thickness\)'.

Evidence · text

> 12.85m \(11.3m true thickness\)

**Step-Out Extension**

Polarity: positive

Definition: Mineralization extended beyond the previously known limit.

Why it applies: The drilling program was 'targeting eastern extensions of the known Bend deposit' and 'confirms mineralization extends eastward along a ~36-42° plunge and remains open at depth and along trend'.

Evidence · text

> targeting eastern extensions of the known Bend deposit. Drilling confirms mineralization extends eastward along a ~36-42° plunge and remains open at depth and along trend.

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: The release details the QA/QC procedures, including the use of Certified Reference Materials and Blank material, and states that samples were processed by ALS Global.

Evidence · text

> Samples from the 2025 Bend drill program followed strict chain of custody from collection, through processing and delivery to ALS Global's \("ALS"\) laboratory in Twin Falls, Idaho. The drill core was inspected and sampled by GreenLight's geologists who insert Certified Reference Materials \("CRMS"\) and Blank material into the sampling stream

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: The copper equivalent calculations explicitly 'do not take into account factors such as metallurgical recoveries or payable metals'.

Evidence · text

> The calculations do not take into account factors such as metallurgical recoveries or payable metals and are shown for demonstrative purposes only.

**Assays Pending**

Polarity: negative

Story-specific tag

Definition: No canonical definition is currently available.

Why it applies: Assay results for holes B25-004 through B25-006, which encountered significant visual sulfide mineralization, are still pending.

Evidence · text

> Results for holes B25-004 through B25-006, which encountered significant visual sulfide mineralization, are expected in the coming weeks.

## Extracted facts

Stored fact records: 28. Some facts used in scoring do not have a stored record.

## Drill Results (28)

### B25-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-0)

Bend · copper

#### Identity

- Hole ID: B25-001
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.56 m
- True Width: 0.5 m
- From: 218.85 m
- To: 219.41 m
- Hole Depth: 279.81 m
- Intercept Depth: 218.85 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-001:218.85-219.41
- Mining Method: underground

#### Location

- Easting: 688514.058
- Northing: 5018602.251
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.855 m
- Azimuth: 344 °
- Dip: 48 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 1.37
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept is narrow and low-grade, but contributes to the overall understanding of the deposit's eastern extension.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low grade and narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 0.49

Context: B25-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-1)

Bend · gold

#### Identity

- Hole ID: B25-001
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 0.54
- Grade Unit: g/t
- Intercept: 0.56 m
- True Width: 0.5 m
- From: 218.85 m
- To: 219.41 m
- Hole Depth: 279.81 m
- Intercept Depth: 218.85 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-001:218.85-219.41
- Mining Method: underground

#### Location

- Easting: 688514.058
- Northing: 5018602.251
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.855 m
- Azimuth: 344 °
- Dip: 48 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept is narrow and low-grade, but contributes to the overall understanding of the deposit's eastern extension.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low grade and narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 0.54

Context: B25-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-2)

Bend · silver

#### Identity

- Hole ID: B25-001
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 18.85
- Grade Unit: g/t
- Intercept: 0.56 m
- True Width: 0.5 m
- From: 218.85 m
- To: 219.41 m
- Hole Depth: 279.81 m
- Intercept Depth: 218.85 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-001:218.85-219.41
- Mining Method: underground

#### Location

- Easting: 688514.058
- Northing: 5018602.251
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.855 m
- Azimuth: 344 °
- Dip: 48 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept is narrow and low-grade, but contributes to the overall understanding of the deposit's eastern extension.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low grade and narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 18.85

Context: B25-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-3)

Bend · tellurium

#### Identity

- Hole ID: B25-001
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 163.5
- Grade Unit: g/t
- Intercept: 0.56 m
- True Width: 0.5 m
- From: 218.85 m
- To: 219.41 m
- Hole Depth: 279.81 m
- Intercept Depth: 218.85 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-001:218.85-219.41
- Mining Method: underground

#### Location

- Easting: 688514.058
- Northing: 5018602.251
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.855 m
- Azimuth: 344 °
- Dip: 48 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept is narrow and low-grade, but contributes to the overall understanding of the deposit's eastern extension.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low grade and narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 163.50

Context: B25-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-4)

Bend · copper

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 10.85 m
- True Width: 9.6 m
- From: 229.95 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 1
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept shows moderate width but low copper grade, contributing to the overall understanding of the deposit's continuity.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low copper grade for a VMS deposit.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 0.32

Context: B25-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-5)

Bend · gold

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 0.54
- Grade Unit: g/t
- Intercept: 10.85 m
- True Width: 9.6 m
- From: 229.95 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept shows moderate width but low gold grade, contributing to the overall understanding of the deposit's continuity.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low gold grade.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 0.54

Context: B25-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-6)

Bend · silver

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 3.95
- Grade Unit: g/t
- Intercept: 10.85 m
- True Width: 9.6 m
- From: 229.95 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept shows moderate width but low silver grade, contributing to the overall understanding of the deposit's continuity.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low silver grade.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 3.95

Context: B25-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-7)

Bend · tellurium

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 59.21
- Grade Unit: g/t
- Intercept: 10.85 m
- True Width: 9.6 m
- From: 229.95 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This intercept shows moderate width but low tellurium grade, contributing to the overall understanding of the deposit's continuity.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Low tellurium grade.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 59.21

Context: B25-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 9.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-8)

Bend · copper

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 1.2
- Grade Unit: %
- Intercept: 1.32 m
- True Width: 1.17 m
- From: 229.95 m
- To: 231.27 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-231.27
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 1.73
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a moderate copper grade over a narrow width, indicating higher-grade zones within the broader mineralization.

- Positive factor: Moderate copper grade for a VMS deposit.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 1.20

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-9)

Bend · gold

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 0.39
- Grade Unit: g/t
- Intercept: 1.32 m
- True Width: 1.17 m
- From: 229.95 m
- To: 231.27 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-231.27
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a low gold grade over a narrow width, indicating higher-grade zones within the broader mineralization.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length and low gold grade.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 0.39

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-10)

Bend · silver

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 5.84
- Grade Unit: g/t
- Intercept: 1.32 m
- True Width: 1.17 m
- From: 229.95 m
- To: 231.27 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-231.27
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a low silver grade over a narrow width, indicating higher-grade zones within the broader mineralization.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length and low silver grade.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 5.84

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-11)

Bend · tellurium

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 102.94
- Grade Unit: g/t
- Intercept: 1.32 m
- True Width: 1.17 m
- From: 229.95 m
- To: 231.27 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:229.95-231.27
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a moderate tellurium grade over a narrow width, indicating higher-grade zones within the broader mineralization.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length and moderate tellurium grade.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 102.94

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-12)

Bend · copper

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 1.52
- Grade Unit: %
- Intercept: 0.9 m
- True Width: 0.8 m
- From: 239.9 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:239.9-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.67
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a strong copper grade over a narrow width, indicating a high-grade lens within the broader mineralization.

- Positive factor: Strong copper grade for a VMS deposit.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 1.52

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-13)

Bend · gold

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 0.9 m
- True Width: 0.8 m
- From: 239.9 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:239.9-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a strong gold grade over a narrow width, indicating a high-grade lens within the broader mineralization.

- Positive factor: Strong gold grade.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 1.60

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-14)

Bend · silver

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 21.9
- Grade Unit: g/t
- Intercept: 0.9 m
- True Width: 0.8 m
- From: 239.9 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:239.9-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a strong silver grade over a narrow width, indicating a high-grade lens within the broader mineralization.

- Positive factor: Strong silver grade.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 21.90

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-15)

Bend · tellurium

#### Identity

- Hole ID: B25-002
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 323
- Grade Unit: g/t
- Intercept: 0.9 m
- True Width: 0.8 m
- From: 239.9 m
- To: 240.8 m
- Hole Depth: 307.24 m
- Intercept Depth: 229.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-002:239.9-240.8
- Mining Method: underground

#### Location

- Easting: 688512.84
- Northing: 5018601.978
- CRS: NAD83 UTM Zone 15N
- Elevation: 413.468 m
- Azimuth: 342 °
- Dip: 58 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept shows a strong tellurium grade over a narrow width, indicating a high-grade lens within the broader mineralization.

- Positive factor: Strong tellurium grade.

- Positive factor: True width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Narrow intercept length.

- Negative factor: Metal equivalent assumptions not fully disclosed.

Evidence · table

> 323.00

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-16)

Bend · copper

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 1.81
- Grade Unit: %
- Intercept: 12.85 m
- True Width: 11.3 m
- From: 257 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.15
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This is a highly significant intercept with exceptional copper grade and substantial width, indicating strong mineralization and extending the known deposit.

- Positive factor: Exceptional copper grade for a VMS deposit \(above 75th percentile\).

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 1.81

Context: B25-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 11.3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-17)

Bend · gold

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 1.75
- Grade Unit: g/t
- Intercept: 12.85 m
- True Width: 11.3 m
- From: 257 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This is a highly significant intercept with strong gold grade and substantial width, indicating strong mineralization and extending the known deposit.

- Positive factor: Strong gold grade.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 1.75

Context: B25-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 11.3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-18)

Bend · silver

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 22.7
- Grade Unit: g/t
- Intercept: 12.85 m
- True Width: 11.3 m
- From: 257 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This is a highly significant intercept with strong silver grade and substantial width, indicating strong mineralization and extending the known deposit.

- Positive factor: Strong silver grade.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 22.70

Context: B25-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 11.3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-19)

Bend · tellurium

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 346.9
- Grade Unit: g/t
- Intercept: 12.85 m
- True Width: 11.3 m
- From: 257 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This is a highly significant intercept with strong tellurium grade and substantial width, indicating strong mineralization and extending the known deposit, though the grade is potentially understated.

- Positive factor: Strong tellurium grade, a critical mineral.

- Positive factor: Significant intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples, potentially understating the true grade.

Evidence · table

> 346.90

Context: B25-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 11.3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-20)

Bend · copper

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 2.68
- Grade Unit: %
- Intercept: 3.56 m
- True Width: 3.13 m
- From: 257 m
- To: 260.56 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-260.56
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.19
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a bonanza-grade copper zone within the broader intercept, highlighting high-grade potential.

- Positive factor: Exceptional copper grade for a VMS deposit.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 2.68

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.13

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-21)

Bend · gold

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 2.77
- Grade Unit: g/t
- Intercept: 3.56 m
- True Width: 3.13 m
- From: 257 m
- To: 260.56 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-260.56
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a strong gold grade zone within the broader intercept, highlighting high-grade potential.

- Positive factor: Strong gold grade.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 2.77

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.13

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-22)

Bend · silver

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 21.17
- Grade Unit: g/t
- Intercept: 3.56 m
- True Width: 3.13 m
- From: 257 m
- To: 260.56 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-260.56
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a strong silver grade zone within the broader intercept, highlighting high-grade potential.

- Positive factor: Strong silver grade.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 21.17

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.13

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-23)

Bend · tellurium

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 481.54
- Grade Unit: g/t
- Intercept: 3.56 m
- True Width: 3.13 m
- From: 257 m
- To: 260.56 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:257-260.56
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a strong tellurium grade zone within the broader intercept, highlighting high-grade potential, though the grade is potentially understated.

- Positive factor: Strong tellurium grade, a critical mineral.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples, potentially understating the true grade.

Evidence · table

> 481.54

Context: Including

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.13

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-24)

Bend · copper

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: copper
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 2.08
- Grade Unit: %
- Intercept: 3.73 m
- True Width: 3.28 m
- From: 266.12 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:266.12-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % Cu Eq
- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents an exceptional copper grade zone within the broader intercept, highlighting high-grade potential.

- Positive factor: Exceptional copper grade for a VMS deposit.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 2.08

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Metal Equivalent Opaque**

Polarity: negative

Definition: Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-25)

Bend · gold

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: gold
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 1.62
- Grade Unit: g/t
- Intercept: 3.73 m
- True Width: 3.28 m
- From: 266.12 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:266.12-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a strong gold grade zone within the broader intercept, highlighting high-grade potential.

- Positive factor: Strong gold grade.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 1.62

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-26)

Bend · silver

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: silver
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 33.68
- Grade Unit: g/t
- Intercept: 3.73 m
- True Width: 3.28 m
- From: 266.12 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:266.12-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a strong silver grade zone within the broader intercept, highlighting high-grade potential.

- Positive factor: Strong silver grade.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples.

Evidence · table

> 33.68

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

### B25-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/greenlight-metals-intersects-significant-copper-rich-vms-mineralization-at-bend--75b7479c-532f-4e5b-ab35-6c5728bbdb5d#fact-drill-facts-27)

Bend · tellurium

#### Identity

- Hole ID: B25-003
- Project: Bend
- Commodity: tellurium
- Region: wisconsin
- Reported Region: wisconsin
- Ticker: GRL

#### Geometry

- Grade: 373.83
- Grade Unit: g/t
- Intercept: 3.73 m
- True Width: 3.28 m
- From: 266.12 m
- To: 269.85 m
- Hole Depth: 276.61 m
- Intercept Depth: 257 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: B25-003:266.12-269.85
- Mining Method: underground

#### Location

- Easting: 688490.294
- Northing: 5018569.989
- CRS: NAD83 UTM Zone 15N
- Elevation: 412.868 m
- Azimuth: 344 °
- Dip: 55.5 °
- Loc. Source: document

#### QA/QC

- Laboratory: ALS
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-09-22T00:00:00.000Z

Reasoning: This sub-intercept represents a strong tellurium grade zone within the broader intercept, highlighting high-grade potential, though the grade is potentially understated.

- Positive factor: Strong tellurium grade, a critical mineral.

- Positive factor: Good intercept length with true width disclosed.

- Positive factor: QA/QC disclosed and QP signed.

- Negative factor: Metal equivalent assumptions not fully disclosed.

- Negative factor: Tellurium grade uncertainty due to overlimit samples, potentially understating the true grade.

Evidence · table

> 373.83

Context: and

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "GreenLight Metals Intersects Significant Copper-Rich VMS Mineralization at Bend Project in Wisconsin Including 12.85m of"

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
