Grid Metals Continues to Expand Cesium Mineralization at Falcon West
Original announcement by tmx on
- Company
- Grid Metals Corp.
- Ticker
- GRDM
- Exchange
- TSX
- Region
- southeastern Manitoba
- Primary commodity
- Cesium
- Secondary commodities
- Lithium, Rubidium, Tantalum
- Document categories
- Drill results
- Extracted
- 2026-09-16 03:09:32 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Grid Metals has reported additional high-grade cesium and lithium drill results from the Lucy South target zone at its Falcon West property. Intercepts include exceptional cesium grades up to 27.81% Cs2O over 0.92 meters and strong lithium grades up to 4.72% Li2O over 5.5 meters, with true widths estimated at 90% of reported lengths. The mineralization remains open in multiple directions, indicating significant expansion potential for the near-surface LCT pegmatite.
Reasoning: The drill results demonstrate exceptional high-grade cesium and strong lithium mineralization over significant widths, confirming and expanding a near-surface LCT pegmatite. The continuity and open nature of the mineralization, coupled with robust QA/QC, indicate a highly positive development for the project.
Positive factors
- Exceptional cesium grades, including multiple intercepts over 10% Cs2O and up to 27.81% Cs2O, significantly exceeding typical high-grade thresholds for rare metals in pegmatites.
- Significant intercept lengths for cesium mineralization, with several intervals over 5 meters and one at 12.45 meters.
- High-grade lithium intercepts, with several over 3% Li2O and up to 4.72% Li2O, indicating a valuable co-product.
- True width estimated at 90% of reported interval lengths, providing good geological confidence.
- The mineralization remains open in multiple directions, suggesting further expansion potential.
- QA/QC protocols are well-disclosed, including certified labs, QP sign-off, and use of blanks, standards, and check assays.
Facts used in scoring: 105
Extracted facts
Stored fact records: 105. Some facts used in scoring do not have a stored record.
Drill Results (105)
LU25-12Falcon West · cesiumGrade: 0.12Grade Unit: %Intercept: 14.65 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 14.65 m
- True Width
- 13.185 m
- From
- 56.87 m
- To
- 71.52 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:56.87-71.52
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate cesium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 14.65 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.12”
Context: 14.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 13.185
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · lithiumGrade: 0.62Grade Unit: %Intercept: 14.65 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.62
- Grade Unit
- %
- Intercept
- 14.65 m
- True Width
- 13.185 m
- From
- 56.87 m
- To
- 71.52 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:56.87-71.52
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 14.65 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.62”
Context: 14.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 13.185
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · rubidiumGrade: 0.38Grade Unit: %Intercept: 14.65 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.38
- Grade Unit
- %
- Intercept
- 14.65 m
- True Width
- 13.185 m
- From
- 56.87 m
- To
- 71.52 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:56.87-71.52
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 14.65 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.38”
Context: 14.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 13.185
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · tantalumGrade: 186Grade Unit: ppm Ta2O5Intercept: 14.65 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 186
- Grade Unit
- ppm Ta2O5
- Intercept
- 14.65 m
- True Width
- 13.185 m
- From
- 56.87 m
- To
- 71.52 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:56.87-71.52
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 14.65 m.
- True width estimated at 90% of reported length.
Evidence · table
“186”
Context: 14.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 13.185
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · cesiumGrade: 0.43Grade Unit: %Intercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.43
- Grade Unit
- %
- Intercept
- 1.05 m
- True Width
- 0.945 m
- From
- 61.9 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:61.9-62.95
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.43”
Context: 1.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.945
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · lithiumGrade: 0.98Grade Unit: %Intercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.98
- Grade Unit
- %
- Intercept
- 1.05 m
- True Width
- 0.945 m
- From
- 61.9 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:61.9-62.95
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate lithium grade over a narrow width, part of a broader interval.
Positive factors
- Moderate lithium grade (0.98% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“0.98”
Context: 1.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.945
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · rubidiumGrade: 0.43Grade Unit: %Intercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.43
- Grade Unit
- %
- Intercept
- 1.05 m
- True Width
- 0.945 m
- From
- 61.9 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:61.9-62.95
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.43”
Context: 1.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.945
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-12Falcon West · tantalumGrade: 144Grade Unit: ppm Ta2O5Intercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- LU25-12
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 144
- Grade Unit
- ppm Ta2O5
- Intercept
- 1.05 m
- True Width
- 0.945 m
- From
- 61.9 m
- To
- 62.95 m
- Hole Depth
- 81 m
- Intercept Depth
- 56.87 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-12:61.9-62.95
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321650
- Northing
- 5502586
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333.1 m
- Azimuth
- 34 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“144”
Context: 1.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.945
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-13Falcon West · cesiumGrade: 0.04Grade Unit: %Intercept: 7.61 mView all detailsHide details
Identity
- Hole ID
- LU25-13
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 7.61 m
- True Width
- 6.849 m
- From
- 1.5 m
- To
- 9.11 m
- Hole Depth
- 51 m
- Intercept Depth
- 1.5 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-13:1.5-9.11
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321603
- Northing
- 5502633
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 327.7 m
- Azimuth
- 98 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.04”
Context: 7.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.849
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-13Falcon West · lithiumGrade: 0.33Grade Unit: %Intercept: 7.61 mView all detailsHide details
Identity
- Hole ID
- LU25-13
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 7.61 m
- True Width
- 6.849 m
- From
- 1.5 m
- To
- 9.11 m
- Hole Depth
- 51 m
- Intercept Depth
- 1.5 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-13:1.5-9.11
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321603
- Northing
- 5502633
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 327.7 m
- Azimuth
- 98 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.33”
Context: 7.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.849
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-13Falcon West · rubidiumGrade: 0.23Grade Unit: %Intercept: 7.61 mView all detailsHide details
Identity
- Hole ID
- LU25-13
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.23
- Grade Unit
- %
- Intercept
- 7.61 m
- True Width
- 6.849 m
- From
- 1.5 m
- To
- 9.11 m
- Hole Depth
- 51 m
- Intercept Depth
- 1.5 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-13:1.5-9.11
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321603
- Northing
- 5502633
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 327.7 m
- Azimuth
- 98 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.23”
Context: 7.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.849
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-13Falcon West · tantalumGrade: 266Grade Unit: ppm Ta2O5Intercept: 7.61 mView all detailsHide details
Identity
- Hole ID
- LU25-13
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 266
- Grade Unit
- ppm Ta2O5
- Intercept
- 7.61 m
- True Width
- 6.849 m
- From
- 1.5 m
- To
- 9.11 m
- Hole Depth
- 51 m
- Intercept Depth
- 1.5 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-13:1.5-9.11
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321603
- Northing
- 5502633
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 327.7 m
- Azimuth
- 98 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate tantalum grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“266”
Context: 7.61
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.849
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-15Falcon West · cesiumGrade: 0.32Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- LU25-15
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 3.3 m
- True Width
- 2.97 m
- From
- 24.1 m
- To
- 27.4 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.1 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-15:24.1-27.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.32”
Context: 3.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-15Falcon West · lithiumGrade: 3.89Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- LU25-15
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 3.89
- Grade Unit
- %
- Intercept
- 3.3 m
- True Width
- 2.97 m
- From
- 24.1 m
- To
- 27.4 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.1 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-15:24.1-27.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (3.89% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“3.89”
Context: 3.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-15Falcon West · rubidiumGrade: 0.1Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- LU25-15
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 3.3 m
- True Width
- 2.97 m
- From
- 24.1 m
- To
- 27.4 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.1 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-15:24.1-27.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.10”
Context: 3.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-15Falcon West · tantalumGrade: 59.5Grade Unit: ppm Ta2O5Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- LU25-15
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 59.5
- Grade Unit
- ppm Ta2O5
- Intercept
- 3.3 m
- True Width
- 2.97 m
- From
- 24.1 m
- To
- 27.4 m
- Hole Depth
- 42 m
- Intercept Depth
- 24.1 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-15:24.1-27.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“59.5”
Context: 3.30
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · cesiumGrade: 0.13Grade Unit: %Intercept: 3.43 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 3.43 m
- True Width
- 3.087 m
- From
- 24 m
- To
- 27.43 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24-27.43
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.13”
Context: 3.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.087
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · lithiumGrade: 0.46Grade Unit: %Intercept: 3.43 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.46
- Grade Unit
- %
- Intercept
- 3.43 m
- True Width
- 3.087 m
- From
- 24 m
- To
- 27.43 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24-27.43
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.46”
Context: 3.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.087
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · rubidiumGrade: 0.54Grade Unit: %Intercept: 3.43 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.54
- Grade Unit
- %
- Intercept
- 3.43 m
- True Width
- 3.087 m
- From
- 24 m
- To
- 27.43 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24-27.43
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.54”
Context: 3.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.087
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · tantalumGrade: 227Grade Unit: ppm Ta2O5Intercept: 3.43 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 227
- Grade Unit
- ppm Ta2O5
- Intercept
- 3.43 m
- True Width
- 3.087 m
- From
- 24 m
- To
- 27.43 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24-27.43
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate tantalum grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“227”
Context: 3.43
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.087
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · cesiumGrade: 0.17Grade Unit: %Intercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 2.05 m
- True Width
- 1.845 m
- From
- 24.97 m
- To
- 27.02 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24.97-27.02
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.17”
Context: 2.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.845
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · lithiumGrade: 0.59Grade Unit: %Intercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 2.05 m
- True Width
- 1.845 m
- From
- 24.97 m
- To
- 27.02 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24.97-27.02
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.59”
Context: 2.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.845
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · rubidiumGrade: 0.61Grade Unit: %Intercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.61
- Grade Unit
- %
- Intercept
- 2.05 m
- True Width
- 1.845 m
- From
- 24.97 m
- To
- 27.02 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24.97-27.02
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.61”
Context: 2.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.845
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-16Falcon West · tantalumGrade: 287Grade Unit: ppm Ta2O5Intercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- LU25-16
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 287
- Grade Unit
- ppm Ta2O5
- Intercept
- 2.05 m
- True Width
- 1.845 m
- From
- 24.97 m
- To
- 27.02 m
- Hole Depth
- 60 m
- Intercept Depth
- 24 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-16:24.97-27.02
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 250 °
- Dip
- -65 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“287”
Context: 2.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.845
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-17Falcon West · cesiumGrade: 0.12Grade Unit: %Intercept: 7.8 mView all detailsHide details
Identity
- Hole ID
- LU25-17
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 7.8 m
- True Width
- 7.02 m
- From
- 19.2 m
- To
- 27 m
- Hole Depth
- 42 m
- Intercept Depth
- 19.2 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-17:19.2-27
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 300 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.12”
Context: 7.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.02
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-17Falcon West · lithiumGrade: 0.55Grade Unit: %Intercept: 7.8 mView all detailsHide details
Identity
- Hole ID
- LU25-17
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.55
- Grade Unit
- %
- Intercept
- 7.8 m
- True Width
- 7.02 m
- From
- 19.2 m
- To
- 27 m
- Hole Depth
- 42 m
- Intercept Depth
- 19.2 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-17:19.2-27
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 300 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.55”
Context: 7.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.02
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-17Falcon West · rubidiumGrade: 0.45Grade Unit: %Intercept: 7.8 mView all detailsHide details
Identity
- Hole ID
- LU25-17
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 7.8 m
- True Width
- 7.02 m
- From
- 19.2 m
- To
- 27 m
- Hole Depth
- 42 m
- Intercept Depth
- 19.2 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-17:19.2-27
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 300 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.45”
Context: 7.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.02
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-17Falcon West · tantalumGrade: 215Grade Unit: ppm Ta2O5Intercept: 7.8 mView all detailsHide details
Identity
- Hole ID
- LU25-17
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 215
- Grade Unit
- ppm Ta2O5
- Intercept
- 7.8 m
- True Width
- 7.02 m
- From
- 19.2 m
- To
- 27 m
- Hole Depth
- 42 m
- Intercept Depth
- 19.2 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-17:19.2-27
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 300 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate tantalum grade over a moderate width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“215”
Context: 7.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.02
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · cesiumGrade: 6.01Grade Unit: %Intercept: 7.35 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 6.01
- Grade Unit
- %
- Intercept
- 7.35 m
- True Width
- 6.615 m
- From
- 20.75 m
- To
- 28.1 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:20.75-28.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.
Positive factors
- Exceptional cesium grade (6.01% Cs2O).
- Good intercept length of 7.35 m.
- True width estimated at 90% of reported length.
Evidence · table
“6.01”
Context: 7.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.615
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · lithiumGrade: 0.84Grade Unit: %Intercept: 7.35 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.84
- Grade Unit
- %
- Intercept
- 7.35 m
- True Width
- 6.615 m
- From
- 20.75 m
- To
- 28.1 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:20.75-28.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate lithium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Moderate lithium grade (0.84% Li2O).
- Good intercept length of 7.35 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.84”
Context: 7.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.615
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · rubidiumGrade: 0.32Grade Unit: %Intercept: 7.35 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 7.35 m
- True Width
- 6.615 m
- From
- 20.75 m
- To
- 28.1 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:20.75-28.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.32”
Context: 7.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.615
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · tantalumGrade: 49.5Grade Unit: ppm Ta2O5Intercept: 7.35 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 49.5
- Grade Unit
- ppm Ta2O5
- Intercept
- 7.35 m
- True Width
- 6.615 m
- From
- 20.75 m
- To
- 28.1 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:20.75-28.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“49.5”
Context: 7.35
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.615
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · cesiumGrade: 10.59Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 10.59
- Grade Unit
- %
- Intercept
- 3.9 m
- True Width
- 3.51 m
- From
- 22.7 m
- To
- 26.6 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:22.7-26.6
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.
Positive factors
- Exceptional cesium grade (10.59% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“10.59”
Context: 3.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · lithiumGrade: 0.61Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.61
- Grade Unit
- %
- Intercept
- 3.9 m
- True Width
- 3.51 m
- From
- 22.7 m
- To
- 26.6 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:22.7-26.6
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.61”
Context: 3.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · rubidiumGrade: 0.3Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 3.9 m
- True Width
- 3.51 m
- From
- 22.7 m
- To
- 26.6 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:22.7-26.6
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.30”
Context: 3.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · tantalumGrade: 40.3Grade Unit: ppm Ta2O5Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 40.3
- Grade Unit
- ppm Ta2O5
- Intercept
- 3.9 m
- True Width
- 3.51 m
- From
- 22.7 m
- To
- 26.6 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:22.7-26.6
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“40.3”
Context: 3.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · cesiumGrade: 20.89Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 20.89
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.9 m
- From
- 23.25 m
- To
- 24.25 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:23.25-24.25
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a narrow width, representing a very high-grade zone.
Positive factors
- Bonanza cesium grade (20.89% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“20.89”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · lithiumGrade: 0.49Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.49
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.9 m
- From
- 23.25 m
- To
- 24.25 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:23.25-24.25
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.49”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-18Falcon West · rubidiumGrade: 0.61Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- LU25-18
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.61
- Grade Unit
- %
- Intercept
- 1 m
- True Width
- 0.9 m
- From
- 23.25 m
- To
- 24.25 m
- Hole Depth
- 36 m
- Intercept Depth
- 20.75 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-18:23.25-24.25
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502619
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.61”
Context: 1.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · cesiumGrade: 0.07Grade Unit: %Intercept: 4.22 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 4.22 m
- True Width
- 3.798 m
- From
- 31.85 m
- To
- 36.07 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:31.85-36.07
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.07”
Context: 4.22
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.798
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · lithiumGrade: 2.06Grade Unit: %Intercept: 4.22 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 2.06
- Grade Unit
- %
- Intercept
- 4.22 m
- True Width
- 3.798 m
- From
- 31.85 m
- To
- 36.07 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:31.85-36.07
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (2.06% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“2.06”
Context: 4.22
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.798
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · rubidiumGrade: 0.26Grade Unit: %Intercept: 4.22 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 4.22 m
- True Width
- 3.798 m
- From
- 31.85 m
- To
- 36.07 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:31.85-36.07
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.26”
Context: 4.22
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.798
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · tantalumGrade: 94.4Grade Unit: ppm Ta2O5Intercept: 4.22 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 94.4
- Grade Unit
- ppm Ta2O5
- Intercept
- 4.22 m
- True Width
- 3.798 m
- From
- 31.85 m
- To
- 36.07 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:31.85-36.07
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“94.4”
Context: 4.22
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.798
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · cesiumGrade: 0.04Grade Unit: %Intercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 1.8 m
- True Width
- 1.62 m
- From
- 32.29 m
- To
- 34.09 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:32.29-34.09
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.04”
Context: 1.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.62
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · lithiumGrade: 4.04Grade Unit: %Intercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 4.04
- Grade Unit
- %
- Intercept
- 1.8 m
- True Width
- 1.62 m
- From
- 32.29 m
- To
- 34.09 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:32.29-34.09
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (4.04% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“4.04”
Context: 1.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.62
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · rubidiumGrade: 0.12Grade Unit: %Intercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 1.8 m
- True Width
- 1.62 m
- From
- 32.29 m
- To
- 34.09 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:32.29-34.09
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.12”
Context: 1.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.62
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-19Falcon West · tantalumGrade: 59.2Grade Unit: ppm Ta2O5Intercept: 1.8 mView all detailsHide details
Identity
- Hole ID
- LU25-19
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 59.2
- Grade Unit
- ppm Ta2O5
- Intercept
- 1.8 m
- True Width
- 1.62 m
- From
- 32.29 m
- To
- 34.09 m
- Hole Depth
- 51 m
- Intercept Depth
- 31.85 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-19:32.29-34.09
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321629
- Northing
- 5502601
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 333 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“59.2”
Context: 1.80
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.62
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · cesiumGrade: 4.95Grade Unit: %Intercept: 8.05 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 4.95
- Grade Unit
- %
- Intercept
- 8.05 m
- True Width
- 7.245 m
- From
- 18.35 m
- To
- 26.4 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.35-26.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Strong cesium grade over a good width, indicating significant mineralization.
Positive factors
- Strong cesium grade (4.95% Cs2O).
- Good intercept length of 8.05 m.
- True width estimated at 90% of reported length.
Evidence · table
“4.95”
Context: 8.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.245
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · lithiumGrade: 1.04Grade Unit: %Intercept: 8.05 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 1.04
- Grade Unit
- %
- Intercept
- 8.05 m
- True Width
- 7.245 m
- From
- 18.35 m
- To
- 26.4 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.35-26.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate lithium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Moderate lithium grade (1.04% Li2O).
- Good intercept length of 8.05 m.
- True width estimated at 90% of reported length.
Evidence · table
“1.04”
Context: 8.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.245
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · rubidiumGrade: 0.5Grade Unit: %Intercept: 8.05 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 8.05 m
- True Width
- 7.245 m
- From
- 18.35 m
- To
- 26.4 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.35-26.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.50”
Context: 8.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.245
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · tantalumGrade: 108Grade Unit: ppm Ta2O5Intercept: 8.05 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 108
- Grade Unit
- ppm Ta2O5
- Intercept
- 8.05 m
- True Width
- 7.245 m
- From
- 18.35 m
- To
- 26.4 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.35-26.4
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“108”
Context: 8.05
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 7.245
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · cesiumGrade: 9.5Grade Unit: %Intercept: 4.12 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 9.5
- Grade Unit
- %
- Intercept
- 4.12 m
- True Width
- 3.708 m
- From
- 18.73 m
- To
- 22.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.73-22.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.
Positive factors
- Exceptional cesium grade (9.50% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“9.50”
Context: 4.12
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.708
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · lithiumGrade: 0.72Grade Unit: %Intercept: 4.12 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.72
- Grade Unit
- %
- Intercept
- 4.12 m
- True Width
- 3.708 m
- From
- 18.73 m
- To
- 22.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.73-22.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate lithium grade over a good width, part of a broader interval.
Positive factors
- Moderate lithium grade (0.72% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“0.72”
Context: 4.12
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.708
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · rubidiumGrade: 0.39Grade Unit: %Intercept: 4.12 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 4.12 m
- True Width
- 3.708 m
- From
- 18.73 m
- To
- 22.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.73-22.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.39”
Context: 4.12
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.708
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · tantalumGrade: 77.5Grade Unit: ppm Ta2O5Intercept: 4.12 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 77.5
- Grade Unit
- ppm Ta2O5
- Intercept
- 4.12 m
- True Width
- 3.708 m
- From
- 18.73 m
- To
- 22.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:18.73-22.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“77.5”
Context: 4.12
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.708
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · cesiumGrade: 13.36Grade Unit: %Intercept: 2.77 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 13.36
- Grade Unit
- %
- Intercept
- 2.77 m
- True Width
- 2.493 m
- From
- 19.08 m
- To
- 21.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.
Positive factors
- Exceptional cesium grade (13.36% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“13.36”
Context: 2.77
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.493
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · lithiumGrade: 0.2Grade Unit: %Intercept: 2.77 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 2.77 m
- True Width
- 2.493 m
- From
- 19.08 m
- To
- 21.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.20”
Context: 2.77
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.493
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · rubidiumGrade: 0.46Grade Unit: %Intercept: 2.77 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.46
- Grade Unit
- %
- Intercept
- 2.77 m
- True Width
- 2.493 m
- From
- 19.08 m
- To
- 21.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.46”
Context: 2.77
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.493
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · tantalumGrade: 3.07Grade Unit: ppm Ta2O5Intercept: 2.77 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 3.07
- Grade Unit
- ppm Ta2O5
- Intercept
- 2.77 m
- True Width
- 2.493 m
- From
- 19.08 m
- To
- 21.85 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.85
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“3.07”
Context: 2.77
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.493
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · cesiumGrade: 14.18Grade Unit: %Intercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 14.18
- Grade Unit
- %
- Intercept
- 2.42 m
- True Width
- 2.178 m
- From
- 19.08 m
- To
- 21.5 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.5
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.
Positive factors
- Exceptional cesium grade (14.18% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“14.18”
Context: 2.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.178
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · lithiumGrade: 0.12Grade Unit: %Intercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 2.42 m
- True Width
- 2.178 m
- From
- 19.08 m
- To
- 21.5 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.5
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.12”
Context: 2.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.178
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · rubidiumGrade: 0.5Grade Unit: %Intercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 2.42 m
- True Width
- 2.178 m
- From
- 19.08 m
- To
- 21.5 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.5
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.50”
Context: 2.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.178
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · tantalumGrade: 2.48Grade Unit: ppm Ta2O5Intercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 2.48
- Grade Unit
- ppm Ta2O5
- Intercept
- 2.42 m
- True Width
- 2.178 m
- From
- 19.08 m
- To
- 21.5 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-21.5
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“2.48”
Context: 2.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.178
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · cesiumGrade: 27.81Grade Unit: %Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 27.81
- Grade Unit
- %
- Intercept
- 0.92 m
- True Width
- 0.828 m
- From
- 19.08 m
- To
- 20 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-20
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional cesium grade over a narrow width, representing a very high-grade zone.
Positive factors
- Bonanza cesium grade (27.81% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“27.81”
Context: 0.92
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.828
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · lithiumGrade: 0.25Grade Unit: %Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 0.92 m
- True Width
- 0.828 m
- From
- 19.08 m
- To
- 20 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-20
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.25”
Context: 0.92
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.828
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · rubidiumGrade: 0.87Grade Unit: %Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.87
- Grade Unit
- %
- Intercept
- 0.92 m
- True Width
- 0.828 m
- From
- 19.08 m
- To
- 20 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-20
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.87”
Context: 0.92
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.828
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-21Falcon West · tantalumGrade: 6.52Grade Unit: ppm Ta2O5Intercept: 0.92 mView all detailsHide details
Identity
- Hole ID
- LU25-21
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 6.52
- Grade Unit
- ppm Ta2O5
- Intercept
- 0.92 m
- True Width
- 0.828 m
- From
- 19.08 m
- To
- 20 m
- Hole Depth
- 33 m
- Intercept Depth
- 18.35 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-21:19.08-20
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“6.52”
Context: 0.92
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.828
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · cesiumGrade: 3.11Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 3.11
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.495 m
- From
- 21.15 m
- To
- 21.7 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.15-21.7
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Strong cesium grade over a very narrow width, indicating high-grade potential.
Positive factors
- Strong cesium grade (3.11% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“3.11”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.495
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · lithiumGrade: 2.39Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 2.39
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.495 m
- From
- 21.15 m
- To
- 21.7 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.15-21.7
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a very narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (2.39% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“2.39”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.495
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · rubidiumGrade: 0.39Grade Unit: %Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 0.55 m
- True Width
- 0.495 m
- From
- 21.15 m
- To
- 21.7 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.15-21.7
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a very narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.39”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.495
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · tantalumGrade: 50Grade Unit: ppm Ta2O5Intercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 50
- Grade Unit
- ppm Ta2O5
- Intercept
- 0.55 m
- True Width
- 0.495 m
- From
- 21.15 m
- To
- 21.7 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.15-21.7
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a very narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“50.0”
Context: 0.55
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.495
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · cesiumGrade: 0.1Grade Unit: %Intercept: 3.71 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 3.71 m
- True Width
- 3.339 m
- From
- 21.7 m
- To
- 25.41 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.7-25.41
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.10”
Context: 3.71
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.339
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · lithiumGrade: 0.41Grade Unit: %Intercept: 3.71 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.41
- Grade Unit
- %
- Intercept
- 3.71 m
- True Width
- 3.339 m
- From
- 21.7 m
- To
- 25.41 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.7-25.41
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.41”
Context: 3.71
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.339
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · rubidiumGrade: 0.45Grade Unit: %Intercept: 3.71 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 3.71 m
- True Width
- 3.339 m
- From
- 21.7 m
- To
- 25.41 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.7-25.41
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.45”
Context: 3.71
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.339
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-22Falcon West · tantalumGrade: 326Grade Unit: ppm Ta2O5Intercept: 3.71 mView all detailsHide details
Identity
- Hole ID
- LU25-22
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 326
- Grade Unit
- ppm Ta2O5
- Intercept
- 3.71 m
- True Width
- 3.339 m
- From
- 21.7 m
- To
- 25.41 m
- Hole Depth
- 39 m
- Intercept Depth
- 21.15 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-22:21.7-25.41
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 310 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate tantalum grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“326”
Context: 3.71
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.339
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · cesiumGrade: 0.25Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 10 m
- True Width
- 9 m
- From
- 21.9 m
- To
- 31.9 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:21.9-31.9
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 10.0 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.25”
Context: 10.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · lithiumGrade: 0.94Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.94
- Grade Unit
- %
- Intercept
- 10 m
- True Width
- 9 m
- From
- 21.9 m
- To
- 31.9 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:21.9-31.9
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate lithium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Moderate lithium grade (0.94% Li2O).
- Good intercept length of 10.0 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.94”
Context: 10.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · rubidiumGrade: 0.47Grade Unit: %Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.47
- Grade Unit
- %
- Intercept
- 10 m
- True Width
- 9 m
- From
- 21.9 m
- To
- 31.9 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:21.9-31.9
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 10.0 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.47”
Context: 10.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · tantalumGrade: 131Grade Unit: ppm Ta2O5Intercept: 10 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 131
- Grade Unit
- ppm Ta2O5
- Intercept
- 10 m
- True Width
- 9 m
- From
- 21.9 m
- To
- 31.9 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:21.9-31.9
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 10.0 m.
- True width estimated at 90% of reported length.
Evidence · table
“131”
Context: 10.00
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · cesiumGrade: 0.19Grade Unit: %Intercept: 4.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 4.2 m
- True Width
- 3.78 m
- From
- 22.9 m
- To
- 27.1 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:22.9-27.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.19”
Context: 4.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · lithiumGrade: 0.79Grade Unit: %Intercept: 4.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.79
- Grade Unit
- %
- Intercept
- 4.2 m
- True Width
- 3.78 m
- From
- 22.9 m
- To
- 27.1 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:22.9-27.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate lithium grade over a narrow width, part of a broader interval.
Positive factors
- Moderate lithium grade (0.79% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“0.79”
Context: 4.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · rubidiumGrade: 0.73Grade Unit: %Intercept: 4.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.73
- Grade Unit
- %
- Intercept
- 4.2 m
- True Width
- 3.78 m
- From
- 22.9 m
- To
- 27.1 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:22.9-27.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate rubidium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.73”
Context: 4.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · tantalumGrade: 140Grade Unit: ppm Ta2O5Intercept: 4.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 140
- Grade Unit
- ppm Ta2O5
- Intercept
- 4.2 m
- True Width
- 3.78 m
- From
- 22.9 m
- To
- 27.1 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:22.9-27.1
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“140”
Context: 4.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.78
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · cesiumGrade: 0.45Grade Unit: %Intercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 3.2 m
- True Width
- 2.88 m
- From
- 27.1 m
- To
- 30.3 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:27.1-30.3
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.45”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.88
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · lithiumGrade: 1.49Grade Unit: %Intercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 1.49
- Grade Unit
- %
- Intercept
- 3.2 m
- True Width
- 2.88 m
- From
- 27.1 m
- To
- 30.3 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:27.1-30.3
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Strong lithium grade over a narrow width, part of a broader interval.
Positive factors
- Strong lithium grade (1.49% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“1.49”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.88
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · rubidiumGrade: 0.24Grade Unit: %Intercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 3.2 m
- True Width
- 2.88 m
- From
- 27.1 m
- To
- 30.3 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:27.1-30.3
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.24”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.88
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-23Falcon West · tantalumGrade: 122Grade Unit: ppm Ta2O5Intercept: 3.2 mView all detailsHide details
Identity
- Hole ID
- LU25-23
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 122
- Grade Unit
- ppm Ta2O5
- Intercept
- 3.2 m
- True Width
- 2.88 m
- From
- 27.1 m
- To
- 30.3 m
- Hole Depth
- 45 m
- Intercept Depth
- 21.9 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-23:27.1-30.3
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 10 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“122”
Context: 3.20
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.88
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · cesiumGrade: 0.25Grade Unit: %Intercept: 7.6 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 7.6 m
- True Width
- 6.84 m
- From
- 29.01 m
- To
- 36.61 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.01-36.61
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 7.6 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.25”
Context: 7.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.84
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · lithiumGrade: 1.97Grade Unit: %Intercept: 7.6 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 1.97
- Grade Unit
- %
- Intercept
- 7.6 m
- True Width
- 6.84 m
- From
- 29.01 m
- To
- 36.61 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.01-36.61
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a good width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (1.97% Li2O).
- Good intercept length of 7.6 m.
- True width estimated at 90% of reported length.
Evidence · table
“1.97”
Context: 7.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.84
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · rubidiumGrade: 0.26Grade Unit: %Intercept: 7.6 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 7.6 m
- True Width
- 6.84 m
- From
- 29.01 m
- To
- 36.61 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.01-36.61
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 7.6 m.
- True width estimated at 90% of reported length.
Evidence · table
“0.26”
Context: 7.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.84
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · tantalumGrade: 146Grade Unit: ppm Ta2O5Intercept: 7.6 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 146
- Grade Unit
- ppm Ta2O5
- Intercept
- 7.6 m
- True Width
- 6.84 m
- From
- 29.01 m
- To
- 36.61 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.01-36.61
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.
Positive factors
- Good intercept length of 7.6 m.
- True width estimated at 90% of reported length.
Evidence · table
“146”
Context: 7.60
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.84
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · cesiumGrade: 0.3Grade Unit: %Intercept: 3.66 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 3.66 m
- True Width
- 3.294 m
- From
- 29.28 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.28-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.30”
Context: 3.66
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.294
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · lithiumGrade: 3.7Grade Unit: %Intercept: 3.66 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 3.7
- Grade Unit
- %
- Intercept
- 3.66 m
- True Width
- 3.294 m
- From
- 29.28 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.28-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (3.70% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“3.70”
Context: 3.66
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.294
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · rubidiumGrade: 0.04Grade Unit: %Intercept: 3.66 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 3.66 m
- True Width
- 3.294 m
- From
- 29.28 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.28-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.04”
Context: 3.66
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.294
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · tantalumGrade: 164Grade Unit: ppm Ta2O5Intercept: 3.66 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 164
- Grade Unit
- ppm Ta2O5
- Intercept
- 3.66 m
- True Width
- 3.294 m
- From
- 29.28 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:29.28-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“164”
Context: 3.66
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.294
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · cesiumGrade: 0.52Grade Unit: %Intercept: 1.94 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.52
- Grade Unit
- %
- Intercept
- 1.94 m
- True Width
- 1.746 m
- From
- 31 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:31-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate cesium grade over a narrow width, part of a broader interval.
Positive factors
- Moderate cesium grade (0.52% Cs2O).
- True width estimated at 90% of reported length.
Evidence · table
“0.52”
Context: 1.94
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.746
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · lithiumGrade: 3.26Grade Unit: %Intercept: 1.94 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 3.26
- Grade Unit
- %
- Intercept
- 1.94 m
- True Width
- 1.746 m
- From
- 31 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:31-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (3.26% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“3.26”
Context: 1.94
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.746
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · rubidiumGrade: 0.06Grade Unit: %Intercept: 1.94 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 1.94 m
- True Width
- 1.746 m
- From
- 31 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:31-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.06”
Context: 1.94
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.746
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · tantalumGrade: 236Grade Unit: ppm Ta2O5Intercept: 1.94 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 236
- Grade Unit
- ppm Ta2O5
- Intercept
- 1.94 m
- True Width
- 1.746 m
- From
- 31 m
- To
- 32.94 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:31-32.94
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate tantalum grade over a narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“236”
Context: 1.94
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.746
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · cesiumGrade: 0.4Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 0.95 m
- True Width
- 0.855 m
- From
- 34.05 m
- To
- 35 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:34.05-35
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a very narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.40”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.855
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · lithiumGrade: 0.45Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 0.95 m
- True Width
- 0.855 m
- From
- 34.05 m
- To
- 35 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:34.05-35
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak lithium grade over a very narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.45”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.855
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · rubidiumGrade: 1.09Grade Unit: %Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- rubidium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 1.09
- Grade Unit
- %
- Intercept
- 0.95 m
- True Width
- 0.855 m
- From
- 34.05 m
- To
- 35 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:34.05-35
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Moderate rubidium grade over a very narrow width, part of a broader interval.
Positive factors
- Moderate rubidium grade (1.09% Rb2O).
- True width estimated at 90% of reported length.
Evidence · table
“1.09”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.855
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-24Falcon West · tantalumGrade: 125Grade Unit: ppm Ta2O5Intercept: 0.95 mView all detailsHide details
Identity
- Hole ID
- LU25-24
- Project
- Falcon West
- Commodity
- tantalum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 125
- Grade Unit
- ppm Ta2O5
- Intercept
- 0.95 m
- True Width
- 0.855 m
- From
- 34.05 m
- To
- 35 m
- Hole Depth
- 42 m
- Intercept Depth
- 29.01 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-24:34.05-35
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321634
- Northing
- 5502630
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 70 °
- Dip
- -66 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Trace tantalum grade over a very narrow width, part of a broader interval.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“125”
Context: 0.95
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.855
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-25Falcon West · cesiumGrade: 0.2Grade Unit: %Intercept: 4.42 mView all detailsHide details
Identity
- Hole ID
- LU25-25
- Project
- Falcon West
- Commodity
- cesium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 4.42 m
- True Width
- 3.978 m
- From
- 28.16 m
- To
- 32.58 m
- Hole Depth
- 42 m
- Intercept Depth
- 28.16 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-25:28.16-32.58
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321638
- Northing
- 5502620
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.
Positive factors
- True width estimated at 90% of reported length.
Evidence · table
“0.20”
Context: 4.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.978
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
LU25-25Falcon West · lithiumGrade: 3.09Grade Unit: %Intercept: 4.42 mView all detailsHide details
Identity
- Hole ID
- LU25-25
- Project
- Falcon West
- Commodity
- lithium
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- GRDM
Geometry
- Grade
- 3.09
- Grade Unit
- %
- Intercept
- 4.42 m
- True Width
- 3.978 m
- From
- 28.16 m
- To
- 32.58 m
- Hole Depth
- 42 m
- Intercept Depth
- 28.16 m
Classification
- Deposit Type
- LCT pegmatite
- Program
- exploration
- Sample Type
- drill
- Group ID
- LU25-25:28.16-32.58
- Mining Method
- open_pit
Location
- Location
- Lucy South
- Easting
- 321638
- Northing
- 5502620
- CRS
- NAD 83 datum and the UTM Zone 15N projection
- EPSG
- 26915
- Elevation
- 334 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Activation Laboratories and AGAT laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, check_assays
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-03T00:00:00.000Z
Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.
Positive factors
- Exceptional lithium grade (3.09% Li2O).
- True width estimated at 90% of reported length.
Evidence · table
“3.09”
Context: 4.42
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 3.978
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Nearology Playneutral
Value premise rests on proximity to a known deposit rather than own results.
Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.