Grid Metals Continues to Expand Cesium Mineralization at Falcon West

Original announcement by tmx on

Company
Grid Metals Corp.
Ticker
GRDM
Exchange
TSX
Region
southeastern Manitoba
Primary commodity
Cesium
Secondary commodities
Lithium, Rubidium, Tantalum
Document categories
Drill results
Extracted
2026-09-16 03:09:32 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Grid Metals has reported additional high-grade cesium and lithium drill results from the Lucy South target zone at its Falcon West property. Intercepts include exceptional cesium grades up to 27.81% Cs2O over 0.92 meters and strong lithium grades up to 4.72% Li2O over 5.5 meters, with true widths estimated at 90% of reported lengths. The mineralization remains open in multiple directions, indicating significant expansion potential for the near-surface LCT pegmatite.

Reasoning: The drill results demonstrate exceptional high-grade cesium and strong lithium mineralization over significant widths, confirming and expanding a near-surface LCT pegmatite. The continuity and open nature of the mineralization, coupled with robust QA/QC, indicate a highly positive development for the project.

Positive factors

  • Exceptional cesium grades, including multiple intercepts over 10% Cs2O and up to 27.81% Cs2O, significantly exceeding typical high-grade thresholds for rare metals in pegmatites.
  • Significant intercept lengths for cesium mineralization, with several intervals over 5 meters and one at 12.45 meters.
  • High-grade lithium intercepts, with several over 3% Li2O and up to 4.72% Li2O, indicating a valuable co-product.
  • True width estimated at 90% of reported interval lengths, providing good geological confidence.
  • The mineralization remains open in multiple directions, suggesting further expansion potential.
  • QA/QC protocols are well-disclosed, including certified labs, QP sign-off, and use of blanks, standards, and check assays.

Facts used in scoring: 105

Extracted facts

Stored fact records: 105. Some facts used in scoring do not have a stored record.

Drill Results (105)

LU25-12Falcon West · cesiumGrade: 0.12Grade Unit: %Intercept: 14.65 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.12
Grade Unit
%
Intercept
14.65 m
True Width
13.185 m
From
56.87 m
To
71.52 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:56.87-71.52
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate cesium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 14.65 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.12”

Context: 14.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 13.185

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · lithiumGrade: 0.62Grade Unit: %Intercept: 14.65 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.62
Grade Unit
%
Intercept
14.65 m
True Width
13.185 m
From
56.87 m
To
71.52 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:56.87-71.52
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 14.65 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.62”

Context: 14.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 13.185

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · rubidiumGrade: 0.38Grade Unit: %Intercept: 14.65 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.38
Grade Unit
%
Intercept
14.65 m
True Width
13.185 m
From
56.87 m
To
71.52 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:56.87-71.52
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 14.65 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.38”

Context: 14.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 13.185

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · tantalumGrade: 186Grade Unit: ppm Ta2O5Intercept: 14.65 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
186
Grade Unit
ppm Ta2O5
Intercept
14.65 m
True Width
13.185 m
From
56.87 m
To
71.52 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:56.87-71.52
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 14.65 m.
  • True width estimated at 90% of reported length.

Evidence · table

“186”

Context: 14.65

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 13.185

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · cesiumGrade: 0.43Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.43
Grade Unit
%
Intercept
1.05 m
True Width
0.945 m
From
61.9 m
To
62.95 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:61.9-62.95
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.43”

Context: 1.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.945

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · lithiumGrade: 0.98Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.98
Grade Unit
%
Intercept
1.05 m
True Width
0.945 m
From
61.9 m
To
62.95 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:61.9-62.95
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate lithium grade over a narrow width, part of a broader interval.

Positive factors

  • Moderate lithium grade (0.98% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“0.98”

Context: 1.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.945

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · rubidiumGrade: 0.43Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.43
Grade Unit
%
Intercept
1.05 m
True Width
0.945 m
From
61.9 m
To
62.95 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:61.9-62.95
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.43”

Context: 1.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.945

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-12Falcon West · tantalumGrade: 144Grade Unit: ppm Ta2O5Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
LU25-12
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
144
Grade Unit
ppm Ta2O5
Intercept
1.05 m
True Width
0.945 m
From
61.9 m
To
62.95 m
Hole Depth
81 m
Intercept Depth
56.87 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-12:61.9-62.95
Mining Method
open_pit

Location

Location
Lucy South
Easting
321650
Northing
5502586
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333.1 m
Azimuth
34 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“144”

Context: 1.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.945

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-13Falcon West · cesiumGrade: 0.04Grade Unit: %Intercept: 7.61 mView all details
Link to this fact

Identity

Hole ID
LU25-13
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.04
Grade Unit
%
Intercept
7.61 m
True Width
6.849 m
From
1.5 m
To
9.11 m
Hole Depth
51 m
Intercept Depth
1.5 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-13:1.5-9.11
Mining Method
open_pit

Location

Location
Lucy South
Easting
321603
Northing
5502633
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
327.7 m
Azimuth
98 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.04”

Context: 7.61

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.849

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-13Falcon West · lithiumGrade: 0.33Grade Unit: %Intercept: 7.61 mView all details
Link to this fact

Identity

Hole ID
LU25-13
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.33
Grade Unit
%
Intercept
7.61 m
True Width
6.849 m
From
1.5 m
To
9.11 m
Hole Depth
51 m
Intercept Depth
1.5 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-13:1.5-9.11
Mining Method
open_pit

Location

Location
Lucy South
Easting
321603
Northing
5502633
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
327.7 m
Azimuth
98 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.33”

Context: 7.61

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.849

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-13Falcon West · rubidiumGrade: 0.23Grade Unit: %Intercept: 7.61 mView all details
Link to this fact

Identity

Hole ID
LU25-13
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.23
Grade Unit
%
Intercept
7.61 m
True Width
6.849 m
From
1.5 m
To
9.11 m
Hole Depth
51 m
Intercept Depth
1.5 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-13:1.5-9.11
Mining Method
open_pit

Location

Location
Lucy South
Easting
321603
Northing
5502633
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
327.7 m
Azimuth
98 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.23”

Context: 7.61

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.849

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-13Falcon West · tantalumGrade: 266Grade Unit: ppm Ta2O5Intercept: 7.61 mView all details
Link to this fact

Identity

Hole ID
LU25-13
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
266
Grade Unit
ppm Ta2O5
Intercept
7.61 m
True Width
6.849 m
From
1.5 m
To
9.11 m
Hole Depth
51 m
Intercept Depth
1.5 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-13:1.5-9.11
Mining Method
open_pit

Location

Location
Lucy South
Easting
321603
Northing
5502633
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
327.7 m
Azimuth
98 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate tantalum grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“266”

Context: 7.61

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.849

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-15Falcon West · cesiumGrade: 0.32Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
LU25-15
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.32
Grade Unit
%
Intercept
3.3 m
True Width
2.97 m
From
24.1 m
To
27.4 m
Hole Depth
42 m
Intercept Depth
24.1 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-15:24.1-27.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.32”

Context: 3.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.97

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-15Falcon West · lithiumGrade: 3.89Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
LU25-15
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
3.89
Grade Unit
%
Intercept
3.3 m
True Width
2.97 m
From
24.1 m
To
27.4 m
Hole Depth
42 m
Intercept Depth
24.1 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-15:24.1-27.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (3.89% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“3.89”

Context: 3.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.97

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-15Falcon West · rubidiumGrade: 0.1Grade Unit: %Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
LU25-15
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.1
Grade Unit
%
Intercept
3.3 m
True Width
2.97 m
From
24.1 m
To
27.4 m
Hole Depth
42 m
Intercept Depth
24.1 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-15:24.1-27.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.10”

Context: 3.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.97

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-15Falcon West · tantalumGrade: 59.5Grade Unit: ppm Ta2O5Intercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
LU25-15
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
59.5
Grade Unit
ppm Ta2O5
Intercept
3.3 m
True Width
2.97 m
From
24.1 m
To
27.4 m
Hole Depth
42 m
Intercept Depth
24.1 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-15:24.1-27.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“59.5”

Context: 3.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.97

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · cesiumGrade: 0.13Grade Unit: %Intercept: 3.43 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.13
Grade Unit
%
Intercept
3.43 m
True Width
3.087 m
From
24 m
To
27.43 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24-27.43
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.13”

Context: 3.43

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.087

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · lithiumGrade: 0.46Grade Unit: %Intercept: 3.43 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.46
Grade Unit
%
Intercept
3.43 m
True Width
3.087 m
From
24 m
To
27.43 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24-27.43
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.46”

Context: 3.43

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.087

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · rubidiumGrade: 0.54Grade Unit: %Intercept: 3.43 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.54
Grade Unit
%
Intercept
3.43 m
True Width
3.087 m
From
24 m
To
27.43 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24-27.43
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.54”

Context: 3.43

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.087

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · tantalumGrade: 227Grade Unit: ppm Ta2O5Intercept: 3.43 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
227
Grade Unit
ppm Ta2O5
Intercept
3.43 m
True Width
3.087 m
From
24 m
To
27.43 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24-27.43
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate tantalum grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“227”

Context: 3.43

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.087

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · cesiumGrade: 0.17Grade Unit: %Intercept: 2.05 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.17
Grade Unit
%
Intercept
2.05 m
True Width
1.845 m
From
24.97 m
To
27.02 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24.97-27.02
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.17”

Context: 2.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.845

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · lithiumGrade: 0.59Grade Unit: %Intercept: 2.05 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.59
Grade Unit
%
Intercept
2.05 m
True Width
1.845 m
From
24.97 m
To
27.02 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24.97-27.02
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.59”

Context: 2.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.845

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · rubidiumGrade: 0.61Grade Unit: %Intercept: 2.05 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.61
Grade Unit
%
Intercept
2.05 m
True Width
1.845 m
From
24.97 m
To
27.02 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24.97-27.02
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.61”

Context: 2.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.845

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-16Falcon West · tantalumGrade: 287Grade Unit: ppm Ta2O5Intercept: 2.05 mView all details
Link to this fact

Identity

Hole ID
LU25-16
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
287
Grade Unit
ppm Ta2O5
Intercept
2.05 m
True Width
1.845 m
From
24.97 m
To
27.02 m
Hole Depth
60 m
Intercept Depth
24 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-16:24.97-27.02
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
250 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“287”

Context: 2.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.845

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-17Falcon West · cesiumGrade: 0.12Grade Unit: %Intercept: 7.8 mView all details
Link to this fact

Identity

Hole ID
LU25-17
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.12
Grade Unit
%
Intercept
7.8 m
True Width
7.02 m
From
19.2 m
To
27 m
Hole Depth
42 m
Intercept Depth
19.2 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-17:19.2-27
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
300 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.12”

Context: 7.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.02

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-17Falcon West · lithiumGrade: 0.55Grade Unit: %Intercept: 7.8 mView all details
Link to this fact

Identity

Hole ID
LU25-17
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.55
Grade Unit
%
Intercept
7.8 m
True Width
7.02 m
From
19.2 m
To
27 m
Hole Depth
42 m
Intercept Depth
19.2 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-17:19.2-27
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
300 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.55”

Context: 7.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.02

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-17Falcon West · rubidiumGrade: 0.45Grade Unit: %Intercept: 7.8 mView all details
Link to this fact

Identity

Hole ID
LU25-17
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.45
Grade Unit
%
Intercept
7.8 m
True Width
7.02 m
From
19.2 m
To
27 m
Hole Depth
42 m
Intercept Depth
19.2 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-17:19.2-27
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
300 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.45”

Context: 7.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.02

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-17Falcon West · tantalumGrade: 215Grade Unit: ppm Ta2O5Intercept: 7.8 mView all details
Link to this fact

Identity

Hole ID
LU25-17
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
215
Grade Unit
ppm Ta2O5
Intercept
7.8 m
True Width
7.02 m
From
19.2 m
To
27 m
Hole Depth
42 m
Intercept Depth
19.2 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-17:19.2-27
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
300 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate tantalum grade over a moderate width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“215”

Context: 7.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.02

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · cesiumGrade: 6.01Grade Unit: %Intercept: 7.35 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
6.01
Grade Unit
%
Intercept
7.35 m
True Width
6.615 m
From
20.75 m
To
28.1 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:20.75-28.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.

Positive factors

  • Exceptional cesium grade (6.01% Cs2O).
  • Good intercept length of 7.35 m.
  • True width estimated at 90% of reported length.

Evidence · table

“6.01”

Context: 7.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.615

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · lithiumGrade: 0.84Grade Unit: %Intercept: 7.35 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.84
Grade Unit
%
Intercept
7.35 m
True Width
6.615 m
From
20.75 m
To
28.1 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:20.75-28.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate lithium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Moderate lithium grade (0.84% Li2O).
  • Good intercept length of 7.35 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.84”

Context: 7.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.615

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · rubidiumGrade: 0.32Grade Unit: %Intercept: 7.35 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.32
Grade Unit
%
Intercept
7.35 m
True Width
6.615 m
From
20.75 m
To
28.1 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:20.75-28.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.32”

Context: 7.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.615

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · tantalumGrade: 49.5Grade Unit: ppm Ta2O5Intercept: 7.35 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
49.5
Grade Unit
ppm Ta2O5
Intercept
7.35 m
True Width
6.615 m
From
20.75 m
To
28.1 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:20.75-28.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“49.5”

Context: 7.35

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.615

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · cesiumGrade: 10.59Grade Unit: %Intercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
10.59
Grade Unit
%
Intercept
3.9 m
True Width
3.51 m
From
22.7 m
To
26.6 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:22.7-26.6
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.

Positive factors

  • Exceptional cesium grade (10.59% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“10.59”

Context: 3.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.51

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · lithiumGrade: 0.61Grade Unit: %Intercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.61
Grade Unit
%
Intercept
3.9 m
True Width
3.51 m
From
22.7 m
To
26.6 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:22.7-26.6
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.61”

Context: 3.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.51

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · rubidiumGrade: 0.3Grade Unit: %Intercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.3
Grade Unit
%
Intercept
3.9 m
True Width
3.51 m
From
22.7 m
To
26.6 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:22.7-26.6
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.30”

Context: 3.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.51

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · tantalumGrade: 40.3Grade Unit: ppm Ta2O5Intercept: 3.9 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
40.3
Grade Unit
ppm Ta2O5
Intercept
3.9 m
True Width
3.51 m
From
22.7 m
To
26.6 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:22.7-26.6
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“40.3”

Context: 3.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.51

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · cesiumGrade: 20.89Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
20.89
Grade Unit
%
Intercept
1 m
True Width
0.9 m
From
23.25 m
To
24.25 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:23.25-24.25
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a narrow width, representing a very high-grade zone.

Positive factors

  • Bonanza cesium grade (20.89% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“20.89”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · lithiumGrade: 0.49Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.49
Grade Unit
%
Intercept
1 m
True Width
0.9 m
From
23.25 m
To
24.25 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:23.25-24.25
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.49”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-18Falcon West · rubidiumGrade: 0.61Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
LU25-18
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.61
Grade Unit
%
Intercept
1 m
True Width
0.9 m
From
23.25 m
To
24.25 m
Hole Depth
36 m
Intercept Depth
20.75 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-18:23.25-24.25
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502619
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.61”

Context: 1.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · cesiumGrade: 0.07Grade Unit: %Intercept: 4.22 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.07
Grade Unit
%
Intercept
4.22 m
True Width
3.798 m
From
31.85 m
To
36.07 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:31.85-36.07
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.07”

Context: 4.22

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.798

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · lithiumGrade: 2.06Grade Unit: %Intercept: 4.22 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
2.06
Grade Unit
%
Intercept
4.22 m
True Width
3.798 m
From
31.85 m
To
36.07 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:31.85-36.07
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (2.06% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“2.06”

Context: 4.22

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.798

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · rubidiumGrade: 0.26Grade Unit: %Intercept: 4.22 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.26
Grade Unit
%
Intercept
4.22 m
True Width
3.798 m
From
31.85 m
To
36.07 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:31.85-36.07
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.26”

Context: 4.22

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.798

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · tantalumGrade: 94.4Grade Unit: ppm Ta2O5Intercept: 4.22 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
94.4
Grade Unit
ppm Ta2O5
Intercept
4.22 m
True Width
3.798 m
From
31.85 m
To
36.07 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:31.85-36.07
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“94.4”

Context: 4.22

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.798

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · cesiumGrade: 0.04Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.04
Grade Unit
%
Intercept
1.8 m
True Width
1.62 m
From
32.29 m
To
34.09 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:32.29-34.09
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.04”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · lithiumGrade: 4.04Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
4.04
Grade Unit
%
Intercept
1.8 m
True Width
1.62 m
From
32.29 m
To
34.09 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:32.29-34.09
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (4.04% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“4.04”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · rubidiumGrade: 0.12Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.12
Grade Unit
%
Intercept
1.8 m
True Width
1.62 m
From
32.29 m
To
34.09 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:32.29-34.09
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.12”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-19Falcon West · tantalumGrade: 59.2Grade Unit: ppm Ta2O5Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
LU25-19
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
59.2
Grade Unit
ppm Ta2O5
Intercept
1.8 m
True Width
1.62 m
From
32.29 m
To
34.09 m
Hole Depth
51 m
Intercept Depth
31.85 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-19:32.29-34.09
Mining Method
open_pit

Location

Location
Lucy South
Easting
321629
Northing
5502601
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
333 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“59.2”

Context: 1.80

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.62

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · cesiumGrade: 4.95Grade Unit: %Intercept: 8.05 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
4.95
Grade Unit
%
Intercept
8.05 m
True Width
7.245 m
From
18.35 m
To
26.4 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.35-26.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Strong cesium grade over a good width, indicating significant mineralization.

Positive factors

  • Strong cesium grade (4.95% Cs2O).
  • Good intercept length of 8.05 m.
  • True width estimated at 90% of reported length.

Evidence · table

“4.95”

Context: 8.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.245

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · lithiumGrade: 1.04Grade Unit: %Intercept: 8.05 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
1.04
Grade Unit
%
Intercept
8.05 m
True Width
7.245 m
From
18.35 m
To
26.4 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.35-26.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate lithium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Moderate lithium grade (1.04% Li2O).
  • Good intercept length of 8.05 m.
  • True width estimated at 90% of reported length.

Evidence · table

“1.04”

Context: 8.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.245

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · rubidiumGrade: 0.5Grade Unit: %Intercept: 8.05 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.5
Grade Unit
%
Intercept
8.05 m
True Width
7.245 m
From
18.35 m
To
26.4 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.35-26.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.50”

Context: 8.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.245

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · tantalumGrade: 108Grade Unit: ppm Ta2O5Intercept: 8.05 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
108
Grade Unit
ppm Ta2O5
Intercept
8.05 m
True Width
7.245 m
From
18.35 m
To
26.4 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.35-26.4
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“108”

Context: 8.05

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.245

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · cesiumGrade: 9.5Grade Unit: %Intercept: 4.12 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
9.5
Grade Unit
%
Intercept
4.12 m
True Width
3.708 m
From
18.73 m
To
22.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.73-22.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.

Positive factors

  • Exceptional cesium grade (9.50% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“9.50”

Context: 4.12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.708

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · lithiumGrade: 0.72Grade Unit: %Intercept: 4.12 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.72
Grade Unit
%
Intercept
4.12 m
True Width
3.708 m
From
18.73 m
To
22.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.73-22.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate lithium grade over a good width, part of a broader interval.

Positive factors

  • Moderate lithium grade (0.72% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“0.72”

Context: 4.12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.708

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · rubidiumGrade: 0.39Grade Unit: %Intercept: 4.12 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.39
Grade Unit
%
Intercept
4.12 m
True Width
3.708 m
From
18.73 m
To
22.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.73-22.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.39”

Context: 4.12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.708

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · tantalumGrade: 77.5Grade Unit: ppm Ta2O5Intercept: 4.12 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
77.5
Grade Unit
ppm Ta2O5
Intercept
4.12 m
True Width
3.708 m
From
18.73 m
To
22.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:18.73-22.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“77.5”

Context: 4.12

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.708

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · cesiumGrade: 13.36Grade Unit: %Intercept: 2.77 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
13.36
Grade Unit
%
Intercept
2.77 m
True Width
2.493 m
From
19.08 m
To
21.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.

Positive factors

  • Exceptional cesium grade (13.36% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“13.36”

Context: 2.77

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.493

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · lithiumGrade: 0.2Grade Unit: %Intercept: 2.77 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.2
Grade Unit
%
Intercept
2.77 m
True Width
2.493 m
From
19.08 m
To
21.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.20”

Context: 2.77

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.493

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · rubidiumGrade: 0.46Grade Unit: %Intercept: 2.77 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.46
Grade Unit
%
Intercept
2.77 m
True Width
2.493 m
From
19.08 m
To
21.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.46”

Context: 2.77

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.493

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · tantalumGrade: 3.07Grade Unit: ppm Ta2O5Intercept: 2.77 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
3.07
Grade Unit
ppm Ta2O5
Intercept
2.77 m
True Width
2.493 m
From
19.08 m
To
21.85 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.85
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“3.07”

Context: 2.77

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.493

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · cesiumGrade: 14.18Grade Unit: %Intercept: 2.42 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
14.18
Grade Unit
%
Intercept
2.42 m
True Width
2.178 m
From
19.08 m
To
21.5 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.5
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a good width, indicating significant mineralization.

Positive factors

  • Exceptional cesium grade (14.18% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“14.18”

Context: 2.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.178

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · lithiumGrade: 0.12Grade Unit: %Intercept: 2.42 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.12
Grade Unit
%
Intercept
2.42 m
True Width
2.178 m
From
19.08 m
To
21.5 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.5
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.12”

Context: 2.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.178

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · rubidiumGrade: 0.5Grade Unit: %Intercept: 2.42 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.5
Grade Unit
%
Intercept
2.42 m
True Width
2.178 m
From
19.08 m
To
21.5 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.5
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.50”

Context: 2.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.178

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · tantalumGrade: 2.48Grade Unit: ppm Ta2O5Intercept: 2.42 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
2.48
Grade Unit
ppm Ta2O5
Intercept
2.42 m
True Width
2.178 m
From
19.08 m
To
21.5 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-21.5
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“2.48”

Context: 2.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.178

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · cesiumGrade: 27.81Grade Unit: %Intercept: 0.92 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
27.81
Grade Unit
%
Intercept
0.92 m
True Width
0.828 m
From
19.08 m
To
20 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-20
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional cesium grade over a narrow width, representing a very high-grade zone.

Positive factors

  • Bonanza cesium grade (27.81% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“27.81”

Context: 0.92

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.828

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · lithiumGrade: 0.25Grade Unit: %Intercept: 0.92 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.25
Grade Unit
%
Intercept
0.92 m
True Width
0.828 m
From
19.08 m
To
20 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-20
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.25”

Context: 0.92

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.828

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · rubidiumGrade: 0.87Grade Unit: %Intercept: 0.92 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.87
Grade Unit
%
Intercept
0.92 m
True Width
0.828 m
From
19.08 m
To
20 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-20
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.87”

Context: 0.92

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.828

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-21Falcon West · tantalumGrade: 6.52Grade Unit: ppm Ta2O5Intercept: 0.92 mView all details
Link to this fact

Identity

Hole ID
LU25-21
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
6.52
Grade Unit
ppm Ta2O5
Intercept
0.92 m
True Width
0.828 m
From
19.08 m
To
20 m
Hole Depth
33 m
Intercept Depth
18.35 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-21:19.08-20
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“6.52”

Context: 0.92

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.828

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · cesiumGrade: 3.11Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
3.11
Grade Unit
%
Intercept
0.55 m
True Width
0.495 m
From
21.15 m
To
21.7 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.15-21.7
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Strong cesium grade over a very narrow width, indicating high-grade potential.

Positive factors

  • Strong cesium grade (3.11% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“3.11”

Context: 0.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.495

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · lithiumGrade: 2.39Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
2.39
Grade Unit
%
Intercept
0.55 m
True Width
0.495 m
From
21.15 m
To
21.7 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.15-21.7
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a very narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (2.39% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“2.39”

Context: 0.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.495

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · rubidiumGrade: 0.39Grade Unit: %Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.39
Grade Unit
%
Intercept
0.55 m
True Width
0.495 m
From
21.15 m
To
21.7 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.15-21.7
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a very narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.39”

Context: 0.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.495

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · tantalumGrade: 50Grade Unit: ppm Ta2O5Intercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
50
Grade Unit
ppm Ta2O5
Intercept
0.55 m
True Width
0.495 m
From
21.15 m
To
21.7 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.15-21.7
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a very narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“50.0”

Context: 0.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.495

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · cesiumGrade: 0.1Grade Unit: %Intercept: 3.71 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.1
Grade Unit
%
Intercept
3.71 m
True Width
3.339 m
From
21.7 m
To
25.41 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.7-25.41
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.10”

Context: 3.71

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.339

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · lithiumGrade: 0.41Grade Unit: %Intercept: 3.71 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.41
Grade Unit
%
Intercept
3.71 m
True Width
3.339 m
From
21.7 m
To
25.41 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.7-25.41
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.41”

Context: 3.71

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.339

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · rubidiumGrade: 0.45Grade Unit: %Intercept: 3.71 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.45
Grade Unit
%
Intercept
3.71 m
True Width
3.339 m
From
21.7 m
To
25.41 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.7-25.41
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.45”

Context: 3.71

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.339

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-22Falcon West · tantalumGrade: 326Grade Unit: ppm Ta2O5Intercept: 3.71 mView all details
Link to this fact

Identity

Hole ID
LU25-22
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
326
Grade Unit
ppm Ta2O5
Intercept
3.71 m
True Width
3.339 m
From
21.7 m
To
25.41 m
Hole Depth
39 m
Intercept Depth
21.15 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-22:21.7-25.41
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
310 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate tantalum grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“326”

Context: 3.71

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.339

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · cesiumGrade: 0.25Grade Unit: %Intercept: 10 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.25
Grade Unit
%
Intercept
10 m
True Width
9 m
From
21.9 m
To
31.9 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:21.9-31.9
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 10.0 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.25”

Context: 10.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · lithiumGrade: 0.94Grade Unit: %Intercept: 10 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.94
Grade Unit
%
Intercept
10 m
True Width
9 m
From
21.9 m
To
31.9 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:21.9-31.9
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate lithium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Moderate lithium grade (0.94% Li2O).
  • Good intercept length of 10.0 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.94”

Context: 10.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · rubidiumGrade: 0.47Grade Unit: %Intercept: 10 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.47
Grade Unit
%
Intercept
10 m
True Width
9 m
From
21.9 m
To
31.9 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:21.9-31.9
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 10.0 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.47”

Context: 10.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · tantalumGrade: 131Grade Unit: ppm Ta2O5Intercept: 10 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
131
Grade Unit
ppm Ta2O5
Intercept
10 m
True Width
9 m
From
21.9 m
To
31.9 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:21.9-31.9
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 10.0 m.
  • True width estimated at 90% of reported length.

Evidence · table

“131”

Context: 10.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · cesiumGrade: 0.19Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.19
Grade Unit
%
Intercept
4.2 m
True Width
3.78 m
From
22.9 m
To
27.1 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:22.9-27.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.19”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.78

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · lithiumGrade: 0.79Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.79
Grade Unit
%
Intercept
4.2 m
True Width
3.78 m
From
22.9 m
To
27.1 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:22.9-27.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate lithium grade over a narrow width, part of a broader interval.

Positive factors

  • Moderate lithium grade (0.79% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“0.79”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.78

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · rubidiumGrade: 0.73Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.73
Grade Unit
%
Intercept
4.2 m
True Width
3.78 m
From
22.9 m
To
27.1 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:22.9-27.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate rubidium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.73”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.78

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · tantalumGrade: 140Grade Unit: ppm Ta2O5Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
140
Grade Unit
ppm Ta2O5
Intercept
4.2 m
True Width
3.78 m
From
22.9 m
To
27.1 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:22.9-27.1
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“140”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.78

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · cesiumGrade: 0.45Grade Unit: %Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.45
Grade Unit
%
Intercept
3.2 m
True Width
2.88 m
From
27.1 m
To
30.3 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:27.1-30.3
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.45”

Context: 3.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.88

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · lithiumGrade: 1.49Grade Unit: %Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
1.49
Grade Unit
%
Intercept
3.2 m
True Width
2.88 m
From
27.1 m
To
30.3 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:27.1-30.3
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Strong lithium grade over a narrow width, part of a broader interval.

Positive factors

  • Strong lithium grade (1.49% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“1.49”

Context: 3.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.88

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · rubidiumGrade: 0.24Grade Unit: %Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.24
Grade Unit
%
Intercept
3.2 m
True Width
2.88 m
From
27.1 m
To
30.3 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:27.1-30.3
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.24”

Context: 3.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.88

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-23Falcon West · tantalumGrade: 122Grade Unit: ppm Ta2O5Intercept: 3.2 mView all details
Link to this fact

Identity

Hole ID
LU25-23
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
122
Grade Unit
ppm Ta2O5
Intercept
3.2 m
True Width
2.88 m
From
27.1 m
To
30.3 m
Hole Depth
45 m
Intercept Depth
21.9 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-23:27.1-30.3
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
10 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“122”

Context: 3.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.88

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · cesiumGrade: 0.25Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.25
Grade Unit
%
Intercept
7.6 m
True Width
6.84 m
From
29.01 m
To
36.61 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.01-36.61
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 7.6 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.25”

Context: 7.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · lithiumGrade: 1.97Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
1.97
Grade Unit
%
Intercept
7.6 m
True Width
6.84 m
From
29.01 m
To
36.61 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.01-36.61
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a good width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (1.97% Li2O).
  • Good intercept length of 7.6 m.
  • True width estimated at 90% of reported length.

Evidence · table

“1.97”

Context: 7.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · rubidiumGrade: 0.26Grade Unit: %Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.26
Grade Unit
%
Intercept
7.6 m
True Width
6.84 m
From
29.01 m
To
36.61 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.01-36.61
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 7.6 m.
  • True width estimated at 90% of reported length.

Evidence · table

“0.26”

Context: 7.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · tantalumGrade: 146Grade Unit: ppm Ta2O5Intercept: 7.6 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
146
Grade Unit
ppm Ta2O5
Intercept
7.6 m
True Width
6.84 m
From
29.01 m
To
36.61 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.01-36.61
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a good width, contributing to the overall understanding of the deposit.

Positive factors

  • Good intercept length of 7.6 m.
  • True width estimated at 90% of reported length.

Evidence · table

“146”

Context: 7.60

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 6.84

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · cesiumGrade: 0.3Grade Unit: %Intercept: 3.66 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.3
Grade Unit
%
Intercept
3.66 m
True Width
3.294 m
From
29.28 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.28-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.30”

Context: 3.66

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.294

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · lithiumGrade: 3.7Grade Unit: %Intercept: 3.66 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
3.7
Grade Unit
%
Intercept
3.66 m
True Width
3.294 m
From
29.28 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.28-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (3.70% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“3.70”

Context: 3.66

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.294

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · rubidiumGrade: 0.04Grade Unit: %Intercept: 3.66 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.04
Grade Unit
%
Intercept
3.66 m
True Width
3.294 m
From
29.28 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.28-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.04”

Context: 3.66

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.294

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · tantalumGrade: 164Grade Unit: ppm Ta2O5Intercept: 3.66 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
164
Grade Unit
ppm Ta2O5
Intercept
3.66 m
True Width
3.294 m
From
29.28 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:29.28-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“164”

Context: 3.66

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.294

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · cesiumGrade: 0.52Grade Unit: %Intercept: 1.94 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.52
Grade Unit
%
Intercept
1.94 m
True Width
1.746 m
From
31 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:31-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate cesium grade over a narrow width, part of a broader interval.

Positive factors

  • Moderate cesium grade (0.52% Cs2O).
  • True width estimated at 90% of reported length.

Evidence · table

“0.52”

Context: 1.94

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.746

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · lithiumGrade: 3.26Grade Unit: %Intercept: 1.94 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
3.26
Grade Unit
%
Intercept
1.94 m
True Width
1.746 m
From
31 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:31-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (3.26% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“3.26”

Context: 1.94

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.746

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · rubidiumGrade: 0.06Grade Unit: %Intercept: 1.94 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.06
Grade Unit
%
Intercept
1.94 m
True Width
1.746 m
From
31 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:31-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace rubidium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.06”

Context: 1.94

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.746

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · tantalumGrade: 236Grade Unit: ppm Ta2O5Intercept: 1.94 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
236
Grade Unit
ppm Ta2O5
Intercept
1.94 m
True Width
1.746 m
From
31 m
To
32.94 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:31-32.94
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate tantalum grade over a narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“236”

Context: 1.94

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.746

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · cesiumGrade: 0.4Grade Unit: %Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.4
Grade Unit
%
Intercept
0.95 m
True Width
0.855 m
From
34.05 m
To
35 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:34.05-35
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a very narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.40”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.855

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · lithiumGrade: 0.45Grade Unit: %Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.45
Grade Unit
%
Intercept
0.95 m
True Width
0.855 m
From
34.05 m
To
35 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:34.05-35
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak lithium grade over a very narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.45”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.855

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · rubidiumGrade: 1.09Grade Unit: %Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
rubidium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
1.09
Grade Unit
%
Intercept
0.95 m
True Width
0.855 m
From
34.05 m
To
35 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:34.05-35
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Moderate rubidium grade over a very narrow width, part of a broader interval.

Positive factors

  • Moderate rubidium grade (1.09% Rb2O).
  • True width estimated at 90% of reported length.

Evidence · table

“1.09”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.855

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-24Falcon West · tantalumGrade: 125Grade Unit: ppm Ta2O5Intercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
LU25-24
Project
Falcon West
Commodity
tantalum
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
125
Grade Unit
ppm Ta2O5
Intercept
0.95 m
True Width
0.855 m
From
34.05 m
To
35 m
Hole Depth
42 m
Intercept Depth
29.01 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-24:34.05-35
Mining Method
open_pit

Location

Location
Lucy South
Easting
321634
Northing
5502630
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
70 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Trace tantalum grade over a very narrow width, part of a broader interval.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“125”

Context: 0.95

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.855

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-25Falcon West · cesiumGrade: 0.2Grade Unit: %Intercept: 4.42 mView all details
Link to this fact

Identity

Hole ID
LU25-25
Project
Falcon West
Commodity
cesium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
0.2
Grade Unit
%
Intercept
4.42 m
True Width
3.978 m
From
28.16 m
To
32.58 m
Hole Depth
42 m
Intercept Depth
28.16 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-25:28.16-32.58
Mining Method
open_pit

Location

Location
Lucy South
Easting
321638
Northing
5502620
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Weak cesium grade over a narrow width, contributing to the overall understanding of the deposit.

Positive factors

  • True width estimated at 90% of reported length.

Evidence · table

“0.20”

Context: 4.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.978

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

LU25-25Falcon West · lithiumGrade: 3.09Grade Unit: %Intercept: 4.42 mView all details
Link to this fact

Identity

Hole ID
LU25-25
Project
Falcon West
Commodity
lithium
Region
canada_mb
Reported Region
canada_mb
Ticker
GRDM

Geometry

Grade
3.09
Grade Unit
%
Intercept
4.42 m
True Width
3.978 m
From
28.16 m
To
32.58 m
Hole Depth
42 m
Intercept Depth
28.16 m

Classification

Deposit Type
LCT pegmatite
Program
exploration
Sample Type
drill
Group ID
LU25-25:28.16-32.58
Mining Method
open_pit

Location

Location
Lucy South
Easting
321638
Northing
5502620
CRS
NAD 83 datum and the UTM Zone 15N projection
EPSG
26915
Elevation
334 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Activation Laboratories and AGAT laboratories
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, check_assays

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-03T00:00:00.000Z

Reasoning: Exceptional lithium grade over a narrow width, indicating high-grade potential.

Positive factors

  • Exceptional lithium grade (3.09% Li2O).
  • True width estimated at 90% of reported length.

Evidence · table

“3.09”

Context: 4.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.978

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property (Li-Cs) is adjacent to the Mayville Property, and Grid owns 75% of the project."

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.