# Grid Metals Reports Second Batch of Assays from its Phase 2 Drill Program at Falcon West; Cesium Mineralization Intercepted 75 m North of Lucy South Target Area

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056

Original source: https://money.tmx.com/en/quote/GRDM/news/8283388451617786/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal

Publisher: tmx

Original announcement: 2026-05-05T11:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Grid Metals Corp.

- Ticker: GRDM

- Exchange: TSX

- Region: Manitoba

- Primary commodity: Cesium

- Secondary commodities: Lithium, Rubidium, Tantalum

- Document categories: Drill results

- Extracted: 2026-09-16 02:58:06 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

Grid Metals Corp. reported the second batch of assays from its Phase 2 drill program at the Falcon West Property, highlighting significant cesium and lithium intercepts. Notable cesium results include 0.35 m grading 15.05% Cs2O within a larger interval in hole LU26-19, and 0.25 m grading 11.44% Cs2O in LU26-26. The drilling successfully extended cesium mineralization 75 m north of the Lucy South target area, and the company plans to commence a maiden cesium and lithium resource estimate in Q3/26.

Reasoning: The drill results demonstrate significant high-grade cesium mineralization, expanding the known footprint of the Lucy South deposit and providing a strong foundation for an upcoming maiden resource estimate for a critical metal. The disclosure of true width estimates and robust QA/QC protocols further enhances confidence in the results.

- Positive factor: High-grade cesium intercepts, including bonanza grades up to 15.05% Cs2O.

- Positive factor: Extension of cesium mineralization 75m north of the Lucy South target area.

- Positive factor: Plans for a maiden cesium and lithium resource estimate in Q3/26.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: Comprehensive QA/QC procedures disclosed, including certified laboratories and QP sign-off.

- Positive factor: Cesium is designated as a critical metal in the US and Canada.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 103

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 103. Some facts used in scoring do not have a stored record.

## Drill Results (103)

### LU26-12

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-0)

Falcon West · cesium

#### Identity

- Hole ID: LU26-12
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4 m
- From: 54.15 m
- To: 54.65 m
- Hole Depth: 63 m
- Intercept Depth: 54.15 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-12:54.15-54.65

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 319 °
- Dip: -49.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.06

Context: 0.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-12

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-1)

Falcon West · lithium

#### Identity

- Hole ID: LU26-12
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.06
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4 m
- From: 54.15 m
- To: 54.65 m
- Hole Depth: 63 m
- Intercept Depth: 54.15 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-12:54.15-54.65

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 319 °
- Dip: -49.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows an exceptional lithium grade over a narrow width, contributing positively to the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.06% Li2O is exceptional for lithium.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.06

Context: 0.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-12

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-2)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-12
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- True Width: 0.4 m
- From: 54.15 m
- To: 54.65 m
- Hole Depth: 63 m
- Intercept Depth: 54.15 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-12:54.15-54.65

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 319 °
- Dip: -49.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization, contributing to the polymetallic nature of the deposit and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.11% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.11

Context: 0.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-12

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-3)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-12
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 5980
- Grade Unit: ppm
- Intercept: 0.5 m
- True Width: 0.4 m
- From: 54.15 m
- To: 54.65 m
- Hole Depth: 63 m
- Intercept Depth: 54.15 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-12:54.15-54.65

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 319 °
- Dip: -49.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional tantalum mineralization over a narrow width, adding significant polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 5980 ppm Ta2O5 is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 5980

Context: 0.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-13

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-4)

Falcon West · cesium

#### Identity

- Hole ID: LU26-13
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 49.77 m
- To: 49.97 m
- Hole Depth: 60 m
- Intercept Depth: 49.77 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-13:49.77-49.97

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 322.2 °
- Dip: -68 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization over a very narrow width, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.26

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-13

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-5)

Falcon West · lithium

#### Identity

- Hole ID: LU26-13
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.31
- Grade Unit: %
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 49.77 m
- To: 49.97 m
- Hole Depth: 60 m
- Intercept Depth: 49.77 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-13:49.77-49.97

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 322.2 °
- Dip: -68 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows a strong lithium grade over a very narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.31% Li2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.31

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-13

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-6)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-13
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.91
- Grade Unit: %
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 49.77 m
- To: 49.97 m
- Hole Depth: 60 m
- Intercept Depth: 49.77 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-13:49.77-49.97

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 322.2 °
- Dip: -68 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional rubidium mineralization over a very narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.91% Rb2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.91

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-13

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-7)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-13
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 90
- Grade Unit: ppm
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 49.77 m
- To: 49.97 m
- Hole Depth: 60 m
- Intercept Depth: 49.77 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-13:49.77-49.97

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 322.2 °
- Dip: -68 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization over a very narrow width, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 90 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 90.0

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-14

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-8)

Falcon West · cesium

#### Identity

- Hole ID: LU26-14
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 3.45 m
- True Width: 2.76 m
- From: 46.55 m
- To: 50 m
- Hole Depth: 60 m
- Intercept Depth: 46.55 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-14:46.55-50

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 331.6 °
- Dip: -55 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.08

Context: 3.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-14

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-9)

Falcon West · lithium

#### Identity

- Hole ID: LU26-14
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.11
- Grade Unit: %
- Intercept: 3.45 m
- True Width: 2.76 m
- From: 46.55 m
- To: 50 m
- Hole Depth: 60 m
- Intercept Depth: 46.55 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-14:46.55-50

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 331.6 °
- Dip: -55 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate lithium mineralization over a reasonable width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.11% Li2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.11

Context: 3.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-14

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-10)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-14
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 3.45 m
- True Width: 2.76 m
- From: 46.55 m
- To: 50 m
- Hole Depth: 60 m
- Intercept Depth: 46.55 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-14:46.55-50

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 331.6 °
- Dip: -55 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a reasonable width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.21% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.21

Context: 3.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-14

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-11)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-14
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 347
- Grade Unit: ppm
- Intercept: 3.45 m
- True Width: 2.76 m
- From: 46.55 m
- To: 50 m
- Hole Depth: 60 m
- Intercept Depth: 46.55 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-14:46.55-50

#### Location

- Easting: 321719
- Northing: 5502633
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 330 m
- Azimuth: 331.6 °
- Dip: -55 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong tantalum mineralization over a reasonable width, adding polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 347 ppm Ta2O5 is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 347

Context: 3.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-12)

Falcon West · cesium

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 24.35 m
- To: 28 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:24.35-28

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.09

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-13)

Falcon West · lithium

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.47
- Grade Unit: %
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 24.35 m
- To: 28 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:24.35-28

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong lithium mineralization over a reasonable width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.47% Li2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.47

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-14)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 24.35 m
- To: 28 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:24.35-28

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a reasonable width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.22% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.22

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-15)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 828
- Grade Unit: ppm
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 24.35 m
- To: 28 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:24.35-28

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional tantalum mineralization over a reasonable width, adding significant polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 828 ppm Ta2O5 is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 828

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-16)

Falcon West · cesium

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1.35 m
- True Width: 1.08 m
- From: 25.9 m
- To: 27.25 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:25.9-27.25

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.03

Context: 1.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.08

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-17)

Falcon West · lithium

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.91
- Grade Unit: %
- Intercept: 1.35 m
- True Width: 1.08 m
- From: 25.9 m
- To: 27.25 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:25.9-27.25

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a narrow width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.91% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.91

Context: 1.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.08

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-18)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.35 m
- True Width: 1.08 m
- From: 25.9 m
- To: 27.25 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:25.9-27.25

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.01

Context: 1.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.08

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-18

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-19)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-18
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 966
- Grade Unit: ppm
- Intercept: 1.35 m
- True Width: 1.08 m
- From: 25.9 m
- To: 27.25 m
- Hole Depth: 39 m
- Intercept Depth: 24.35 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-18:25.9-27.25

#### Location

- Easting: 321694
- Northing: 5502693
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 327 m
- Azimuth: 328 °
- Dip: -80 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional tantalum mineralization over a narrow width, adding significant polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 966 ppm Ta2O5 is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 966

Context: 1.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.08

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-20)

Falcon West · cesium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.51
- Grade Unit: %
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 26.1 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:26.1-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a good width, contributing significantly to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 2.51% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.51

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-21)

Falcon West · lithium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.77
- Grade Unit: %
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 26.1 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:26.1-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong lithium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.77% Li2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.77

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-22)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 26.1 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:26.1-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.20% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.20

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-23)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 531
- Grade Unit: ppm
- Intercept: 3.65 m
- True Width: 2.92 m
- From: 26.1 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:26.1-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional tantalum mineralization over a good width, adding significant polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 531 ppm Ta2O5 is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 531

Context: 3.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-24)

Falcon West · cesium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 4.81
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 28.25 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a good width, significantly enhancing the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 4.81% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 4.81

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-25)

Falcon West · lithium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.14
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 28.25 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a good width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.14% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.14

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-26)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 28.25 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.33% Rb2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.33

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-27)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 177
- Grade Unit: ppm
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 28.25 m
- To: 29.75 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-29.75

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 177 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 177

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-28)

Falcon West · cesium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 15.05
- Grade Unit: %
- Intercept: 0.35 m
- True Width: 0.28 m
- From: 28.25 m
- To: 28.6 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-28.6

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade cesium mineralization over a narrow width, indicating a bonanza zone and significantly enhancing the project's potential, supported by robust QA/QC.

- Positive factor: Cesium grade of 15.05% Cs2O is exceptional, representing a bonanza intercept.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 15.05

Context: 0.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: 15.05% Cs2O is exceptionally high grade for cesium.

Evidence · table

> 15.05

Context: 0.35

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-29)

Falcon West · lithium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.07
- Grade Unit: %
- Intercept: 0.35 m
- True Width: 0.28 m
- From: 28.25 m
- To: 28.6 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-28.6

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a narrow width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.07% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.07

Context: 0.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-30)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 0.35 m
- True Width: 0.28 m
- From: 28.25 m
- To: 28.6 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-28.6

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional rubidium mineralization over a narrow width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.50% Rb2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.50

Context: 0.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-19

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-31)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-19
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 49
- Grade Unit: ppm
- Intercept: 0.35 m
- True Width: 0.28 m
- From: 28.25 m
- To: 28.6 m
- Hole Depth: 42 m
- Intercept Depth: 26.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-19:28.25-28.6

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.8 °
- Dip: -64.7 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization over a narrow width, but contributes to the overall understanding of the bonanza zone and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 49.0

Context: 0.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.28

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-32)

Falcon West · cesium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 2.35 m
- True Width: 1.88 m
- From: 26.95 m
- To: 29.3 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:26.95-29.3

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.24

Context: 2.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-33)

Falcon West · lithium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 2.35 m
- True Width: 1.88 m
- From: 26.95 m
- To: 29.3 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:26.95-29.3

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak lithium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.09

Context: 2.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-34)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.19
- Grade Unit: %
- Intercept: 2.35 m
- True Width: 1.88 m
- From: 26.95 m
- To: 29.3 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:26.95-29.3

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional rubidium mineralization over a good width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 2.19% Rb2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.19

Context: 2.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-35)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 49
- Grade Unit: ppm
- Intercept: 2.35 m
- True Width: 1.88 m
- From: 26.95 m
- To: 29.3 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:26.95-29.3

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 49

Context: 2.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-36)

Falcon West · cesium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1.72 m
- True Width: 1.376 m
- From: 31.85 m
- To: 33.57 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:31.85-33.57

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.03

Context: 1.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.376

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-37)

Falcon West · lithium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 1.72 m
- True Width: 1.376 m
- From: 31.85 m
- To: 33.57 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:31.85-33.57

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak lithium mineralization over a narrow width, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Lithium grade of 0.73% Li2O is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.73

Context: 1.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.376

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-38)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.72 m
- True Width: 1.376 m
- From: 31.85 m
- To: 33.57 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:31.85-33.57

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.01

Context: 1.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.376

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-39)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 123
- Grade Unit: ppm
- Intercept: 1.72 m
- True Width: 1.376 m
- From: 31.85 m
- To: 33.57 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:31.85-33.57

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 123 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 123

Context: 1.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.376

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-40)

Falcon West · cesium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.88
- Grade Unit: %
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 34.2 m
- To: 34.4 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:34.2-34.4

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a very narrow width, contributing to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 1.88% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.88

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-41)

Falcon West · lithium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.67
- Grade Unit: %
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 34.2 m
- To: 34.4 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:34.2-34.4

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak lithium mineralization over a very narrow width, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Lithium grade of 0.67% Li2O is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.67

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-42)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.69
- Grade Unit: %
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 34.2 m
- To: 34.4 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:34.2-34.4

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional rubidium mineralization over a very narrow width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.69% Rb2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.69

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-20

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-43)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-20
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 0.2 m
- True Width: 0.16 m
- From: 34.2 m
- To: 34.4 m
- Hole Depth: 48 m
- Intercept Depth: 26.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-20:34.2-34.4

#### Location

- Easting: 321681
- Northing: 5502659
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 2 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 10

Context: 0.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-44)

Falcon West · cesium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.17
- Grade Unit: %
- Intercept: 6.4 m
- True Width: 5.12 m
- From: 28.1 m
- To: 34.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.1-34.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate cesium mineralization over a good width, contributing to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 1.17% Cs2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.17

Context: 6.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.12

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-45)

Falcon West · lithium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.95
- Grade Unit: %
- Intercept: 6.4 m
- True Width: 5.12 m
- From: 28.1 m
- To: 34.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.1-34.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a good width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.95% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.95

Context: 6.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.12

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-46)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 6.4 m
- True Width: 5.12 m
- From: 28.1 m
- To: 34.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.1-34.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.20% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.20

Context: 6.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.12

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-47)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 318
- Grade Unit: ppm
- Intercept: 6.4 m
- True Width: 5.12 m
- From: 28.1 m
- To: 34.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.1-34.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong tantalum mineralization over a good width, adding significant polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 318 ppm Ta2O5 is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 318

Context: 6.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.12

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-48)

Falcon West · cesium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 2.8 m
- True Width: 2.24 m
- From: 28.5 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.5-31.3

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.06

Context: 2.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-49)

Falcon West · lithium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 4.33
- Grade Unit: %
- Intercept: 2.8 m
- True Width: 2.24 m
- From: 28.5 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.5-31.3

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade lithium mineralization over a good width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 4.33% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 4.33

Context: 2.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-50)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 2.8 m
- True Width: 2.24 m
- From: 28.5 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.5-31.3

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.06% Rb2O is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.06

Context: 2.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-51)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 81.4
- Grade Unit: ppm
- Intercept: 2.8 m
- True Width: 2.24 m
- From: 28.5 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:28.5-31.3

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 81.4 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 81.4

Context: 2.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-52)

Falcon West · cesium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 3.15
- Grade Unit: %
- Intercept: 2.2 m
- True Width: 1.76 m
- From: 31.3 m
- To: 33.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:31.3-33.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a good width, significantly enhancing the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 3.15% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 3.15

Context: 2.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-53)

Falcon West · lithium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.41
- Grade Unit: %
- Intercept: 2.2 m
- True Width: 1.76 m
- From: 31.3 m
- To: 33.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:31.3-33.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a good width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.41% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.41

Context: 2.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-54)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 2.2 m
- True Width: 1.76 m
- From: 31.3 m
- To: 33.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:31.3-33.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.08% Rb2O is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.08

Context: 2.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-55)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 701
- Grade Unit: ppm
- Intercept: 2.2 m
- True Width: 1.76 m
- From: 31.3 m
- To: 33.5 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:31.3-33.5

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional tantalum mineralization over a good width, adding significant polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 701 ppm Ta2O5 is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 701

Context: 2.20

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-56)

Falcon West · cesium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 6.57
- Grade Unit: %
- Intercept: 0.56 m
- True Width: 0.448 m
- From: 32 m
- To: 32.56 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:32-32.56

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade cesium mineralization over a narrow width, significantly enhancing the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 6.57% Cs2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 6.57

Context: 0.56

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.448

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: 6.57% Cs2O is exceptionally high grade for cesium.

Evidence · table

> 6.57

Context: 0.56

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-57)

Falcon West · lithium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.99
- Grade Unit: %
- Intercept: 0.56 m
- True Width: 0.448 m
- From: 32 m
- To: 32.56 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:32-32.56

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a narrow width, contributing significantly to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.99% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.99

Context: 0.56

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.448

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-58)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.56 m
- True Width: 0.448 m
- From: 32 m
- To: 32.56 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:32-32.56

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.10% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.10

Context: 0.56

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.448

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-21

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-59)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-21
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 150
- Grade Unit: ppm
- Intercept: 0.56 m
- True Width: 0.448 m
- From: 32 m
- To: 32.56 m
- Hole Depth: 45 m
- Intercept Depth: 28.1 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-21:32-32.56

#### Location

- Easting: 321684
- Northing: 5502641
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 313.5 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 150 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 150

Context: 0.56

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.448

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-60)

Falcon West · cesium

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 4.35 m
- True Width: 3.48 m
- From: 29.3 m
- To: 33.65 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-33.65

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.28

Context: 4.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.48

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-61)

Falcon West · lithium

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.36
- Grade Unit: %
- Intercept: 4.35 m
- True Width: 3.48 m
- From: 29.3 m
- To: 33.65 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-33.65

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a good width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.36% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.36

Context: 4.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.48

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-62)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 4.35 m
- True Width: 3.48 m
- From: 29.3 m
- To: 33.65 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-33.65

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.35% Rb2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.35

Context: 4.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.48

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-63)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 171
- Grade Unit: ppm
- Intercept: 4.35 m
- True Width: 3.48 m
- From: 29.3 m
- To: 33.65 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-33.65

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 171 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 171

Context: 4.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.48

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-64)

Falcon West · cesium

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 2 m
- True Width: 1.6 m
- From: 29.3 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-31.3

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.08

Context: 2.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-65)

Falcon West · lithium

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 3.62
- Grade Unit: %
- Intercept: 2 m
- True Width: 1.6 m
- From: 29.3 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-31.3

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade lithium mineralization over a good width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 3.62% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 3.62

Context: 2.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-66)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 2 m
- True Width: 1.6 m
- From: 29.3 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-31.3

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows very weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.03

Context: 2.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-22

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-67)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-22
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 95
- Grade Unit: ppm
- Intercept: 2 m
- True Width: 1.6 m
- From: 29.3 m
- To: 31.3 m
- Hole Depth: 45 m
- Intercept Depth: 29.3 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-22:29.3-31.3

#### Location

- Easting: 321675
- Northing: 5502643
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 95.0 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 95.0

Context: 2.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-68)

Falcon West · cesium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.69
- Grade Unit: %
- Intercept: 1.42 m
- True Width: 1.136 m
- From: 18.7 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:18.7-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate cesium mineralization over a narrow width, contributing to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 0.69% Cs2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.69

Context: 1.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.136

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-69)

Falcon West · lithium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 3.75
- Grade Unit: %
- Intercept: 1.42 m
- True Width: 1.136 m
- From: 18.7 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:18.7-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade lithium mineralization over a narrow width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 3.75% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 3.75

Context: 1.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.136

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-70)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1.42 m
- True Width: 1.136 m
- From: 18.7 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:18.7-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.06% Rb2O is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.06

Context: 1.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.136

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-71)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 51
- Grade Unit: ppm
- Intercept: 1.42 m
- True Width: 1.136 m
- From: 18.7 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:18.7-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 51.0 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 51.0

Context: 1.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.136

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-72)

Falcon West · cesium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 0.71 m
- True Width: 0.568 m
- From: 19.2 m
- To: 19.91 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.2-19.91

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak cesium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.47

Context: 0.71

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.568

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-73)

Falcon West · lithium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 3.42
- Grade Unit: %
- Intercept: 0.71 m
- True Width: 0.568 m
- From: 19.2 m
- To: 19.91 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.2-19.91

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade lithium mineralization over a narrow width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 3.42% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 3.42

Context: 0.71

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.568

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-74)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.71 m
- True Width: 0.568 m
- From: 19.2 m
- To: 19.91 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.2-19.91

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak rubidium mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.04

Context: 0.71

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.568

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-75)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 35.5
- Grade Unit: ppm
- Intercept: 0.71 m
- True Width: 0.568 m
- From: 19.2 m
- To: 19.91 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.2-19.91

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 35.5

Context: 0.71

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.568

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-76)

Falcon West · cesium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.88
- Grade Unit: %
- Intercept: 0.21 m
- True Width: 0.168 m
- From: 19.91 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.91-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a very narrow width, contributing to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 1.88% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.88

Context: 0.21

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.168

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-77)

Falcon West · lithium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.83
- Grade Unit: %
- Intercept: 0.21 m
- True Width: 0.168 m
- From: 19.91 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.91-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptional lithium mineralization over a very narrow width, significantly enhancing the project's polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 2.83% Li2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.83

Context: 0.21

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.168

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-78)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.21 m
- True Width: 0.168 m
- From: 19.91 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.91-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a very narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.17% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.17

Context: 0.21

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.168

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-23

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-79)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-23
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 128.1
- Grade Unit: ppm
- Intercept: 0.21 m
- True Width: 0.168 m
- From: 19.91 m
- To: 20.12 m
- Hole Depth: 30 m
- Intercept Depth: 18.7 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-23:19.91-20.12

#### Location

- Easting: 321666
- Northing: 5502677
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 314.4 °
- Dip: -64.9 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a very narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 128.1 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 128.1

Context: 0.21

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.168

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-80)

Falcon West · cesium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.38
- Grade Unit: %
- Intercept: 4.85 m
- True Width: 3.88 m
- From: 16.95 m
- To: 21.8 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:16.95-21.8

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate cesium mineralization over a good width, contributing to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 1.38% Cs2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.38

Context: 4.85

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-81)

Falcon West · lithium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.15
- Grade Unit: %
- Intercept: 4.85 m
- True Width: 3.88 m
- From: 16.95 m
- To: 21.8 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:16.95-21.8

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate lithium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.15% Li2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.15

Context: 4.85

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-82)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 4.85 m
- True Width: 3.88 m
- From: 16.95 m
- To: 21.8 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:16.95-21.8

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.26% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.26

Context: 4.85

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-83)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 142
- Grade Unit: ppm
- Intercept: 4.85 m
- True Width: 3.88 m
- From: 16.95 m
- To: 21.8 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:16.95-21.8

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 142 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 142

Context: 4.85

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.88

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-84)

Falcon West · cesium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.87
- Grade Unit: %
- Intercept: 2.25 m
- True Width: 1.8 m
- From: 18.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:18.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a good width, contributing significantly to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 2.87% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.87

Context: 2.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-85)

Falcon West · lithium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.65
- Grade Unit: %
- Intercept: 2.25 m
- True Width: 1.8 m
- From: 18.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:18.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong lithium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.65% Li2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.65

Context: 2.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-86)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 2.25 m
- True Width: 1.8 m
- From: 18.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:18.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.26% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.26

Context: 2.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-87)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 70.4
- Grade Unit: ppm
- Intercept: 2.25 m
- True Width: 1.8 m
- From: 18.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:18.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 70.4 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 70.4

Context: 2.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-88)

Falcon West · cesium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 6.93
- Grade Unit: %
- Intercept: 0.25 m
- True Width: 0.2 m
- From: 20.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:20.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows exceptionally high-grade cesium mineralization over a very narrow width, significantly enhancing the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 6.93% Cs2O is exceptional.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 6.93

Context: 0.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: 6.93% Cs2O is exceptionally high grade for cesium.

Evidence · table

> 6.93

Context: 0.25

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-89)

Falcon West · lithium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.62
- Grade Unit: %
- Intercept: 0.25 m
- True Width: 0.2 m
- From: 20.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:20.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong lithium mineralization over a very narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.62% Li2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.62

Context: 0.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-90)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 0.25 m
- True Width: 0.2 m
- From: 20.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:20.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a very narrow width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.26% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.26

Context: 0.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-24

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-91)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-24
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 50
- Grade Unit: ppm
- Intercept: 0.25 m
- True Width: 0.2 m
- From: 20.1 m
- To: 20.35 m
- Hole Depth: 33 m
- Intercept Depth: 16.95 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-24:20.1-20.35

#### Location

- Easting: 321664
- Northing: 5502665
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 316.1 °
- Dip: -65.5 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 50.0 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 50.0

Context: 0.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-92)

Falcon West · cesium

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 2.44
- Grade Unit: %
- Intercept: 1.73 m
- True Width: 1.384 m
- From: 23.25 m
- To: 24.98 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.98

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a good width, contributing significantly to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 2.44% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 2.44

Context: 1.73

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.384

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-93)

Falcon West · lithium

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 1.73 m
- True Width: 1.384 m
- From: 23.25 m
- To: 24.98 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.98

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate lithium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 0.99% Li2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.99

Context: 1.73

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.384

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-94)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 1.73 m
- True Width: 1.384 m
- From: 23.25 m
- To: 24.98 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.98

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.26% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.26

Context: 1.73

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.384

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-95)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 194
- Grade Unit: ppm
- Intercept: 1.73 m
- True Width: 1.384 m
- From: 23.25 m
- To: 24.98 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.98

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate tantalum mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Tantalum grade of 194 ppm Ta2O5 is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 194

Context: 1.73

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.384

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-96)

Falcon West · cesium

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 4.54
- Grade Unit: %
- Intercept: 0.8 m
- True Width: 0.64 m
- From: 23.25 m
- To: 24.05 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.05

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong cesium mineralization over a good width, significantly enhancing the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 4.54% Cs2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 4.54

Context: 0.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-97)

Falcon West · lithium

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.11
- Grade Unit: %
- Intercept: 0.8 m
- True Width: 0.64 m
- From: 23.25 m
- To: 24.05 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.05

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate lithium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 1.11% Li2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.11

Context: 0.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-98)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 0.8 m
- True Width: 0.64 m
- From: 23.25 m
- To: 24.05 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.05

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.18% Rb2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.18

Context: 0.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-25

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-99)

Falcon West · tantalum

#### Identity

- Hole ID: LU26-25
- Project: Falcon West
- Commodity: tantalum
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 80
- Grade Unit: ppm
- Intercept: 0.8 m
- True Width: 0.64 m
- From: 23.25 m
- To: 24.05 m
- Hole Depth: 48 m
- Intercept Depth: 23.25 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-25:23.25-24.05

#### Location

- Easting: 321666
- Northing: 5502655
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 328 m
- Azimuth: 336.1 °
- Dip: -65.1 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows weak tantalum mineralization, but contributes to the overall understanding of the deposit and is supported by robust QA/QC.

- Positive factor: Tantalum grade of 80.0 ppm Ta2O5 is weak.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 80.0

Context: 0.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-26

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-100)

Falcon West · cesium

#### Identity

- Hole ID: LU26-26
- Project: Falcon West
- Commodity: cesium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 1.44
- Grade Unit: %
- Intercept: 3.34 m
- True Width: 2.672 m
- From: 24.9 m
- To: 28.24 m
- Hole Depth: 39 m
- Intercept Depth: 24.9 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-26:24.9-28.24

#### Location

- Easting: 321660
- Northing: 5502648
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate cesium mineralization over a good width, contributing to the project's potential and supported by robust QA/QC.

- Positive factor: Cesium grade of 1.44% Cs2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 1.44

Context: 3.34

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.672

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-26

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-101)

Falcon West · lithium

#### Identity

- Hole ID: LU26-26
- Project: Falcon West
- Commodity: lithium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.97
- Grade Unit: %
- Intercept: 3.34 m
- True Width: 2.672 m
- From: 24.9 m
- To: 28.24 m
- Hole Depth: 39 m
- Intercept Depth: 24.9 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-26:24.9-28.24

#### Location

- Easting: 321660
- Northing: 5502648
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows moderate lithium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Lithium grade of 0.97% Li2O is moderate.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.97

Context: 3.34

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.672

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

### LU26-26

[Link to this fact](https://atlas-extractions.minestarters.com/news/grid-metals-reports-second-batch-of-assays-from-its-phase-2-drill-program-at-fal--1fe9ab24-ac72-4474-a7ce-deed8f098056#fact-drill-facts-102)

Falcon West · rubidium

#### Identity

- Hole ID: LU26-26
- Project: Falcon West
- Commodity: rubidium
- Region: canada\_mb
- Reported Region: canada\_mb
- Ticker: GRDM

#### Geometry

- Grade: 0.39
- Grade Unit: %
- Intercept: 3.34 m
- True Width: 2.672 m
- From: 24.9 m
- To: 28.24 m
- Hole Depth: 39 m
- Intercept Depth: 24.9 m

#### Classification

- Deposit Type: other
- Program: mixed
- Sample Type: drill
- Group ID: LU26-26:24.9-28.24

#### Location

- Easting: 321660
- Northing: 5502648
- CRS: NAD 83 datum and the UTM Zone 15N projection
- Elevation: 329 m
- Azimuth: 315.4 °
- Dip: -65.2 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Activation Laboratories and AGAT laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-05-05T00:00:00.000Z

Reasoning: This intercept shows strong rubidium mineralization over a good width, contributing to the polymetallic potential and supported by robust QA/QC.

- Positive factor: Rubidium grade of 0.39% Rb2O is strong.

- Positive factor: True width estimated to be between 80% and 100% of reported interval lengths.

- Positive factor: QA/QC procedures disclosed, including certified laboratories and QP sign-off.

Evidence · table

> 0.39

Context: 3.34

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.672

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

**Nearology Play**

Polarity: neutral

Definition: Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Donner Property \(Li-Cs\) is adjacent to the Mayville Property, and Grid owns 75% of the project."

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.