High-Grade Fluorspar Identified at the Ashram Project's Mallard Prospect

Original announcement by tmx on

Company
Mont Royal Resources Ltd
Ticker
MRZL
Exchange
TSX
Region
Québec, Canada
Primary commodity
Fluorspar
Secondary commodities
Niobium
Document categories
Drill results
Extracted
2026-09-18 10:51:22 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Mont Royal Resources has announced high-grade fluorspar results from historical drilling at its Mallard Prospect, part of the Ashram Project in Québec, Canada. Re-interpretation of previous niobium-focused drill holes revealed significant fluorspar intercepts, including up to 39.8% CaF2. The company plans further exploration to expand and delineate these high-grade zones, highlighting the strategic importance of fluorspar in global markets.

Reasoning: The document reports high-grade fluorspar intercepts from historical drilling at the Mallard Prospect, re-interpreting previous niobium-focused work. The results confirm significant fluorspar potential in a strategically important critical mineral, supported by robust QA/QC and QP sign-off, despite being historical and lacking true width information.

Positive factors

  • High-grade fluorspar intercepts confirmed from historical drilling
  • Strategic importance of fluorspar as a critical mineral
  • Potential for future co-development with nearby Ashram Deposit
  • Detailed QA/QC disclosure and QP sign-off

Negative factors

  • Results are historical, not new drilling
  • True width of mineralization is not known
  • No specific cut-off grade used for compositing

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 20

Extracted facts

Stored fact records: 20. Some facts used in scoring do not have a stored record.

Drill Results (20)

EC10-033Ashram · fluorsparGrade: 26.1Grade Unit: %Intercept: 32.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-033
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
26.1
Grade Unit
%
Intercept
32.4 m
From
203.9 m
To
236.3 m
Hole Depth
353.1 m
Intercept Depth
203.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-033:203.9-236.3

Location

Location
Mallard Prospect
Easting
538077.14
Northing
6310973.22
CRS
UTM NAD83 Zone 19N
Elevation
284.68 m
Azimuth
235 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • High fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“32.4m @ 26.1% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-033Ashram · niobiumGrade: 0.4Grade Unit: %Intercept: 32.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-033
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.4
Grade Unit
%
Intercept
32.4 m
From
203.9 m
To
236.3 m
Hole Depth
353.1 m
Intercept Depth
203.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-033:203.9-236.3

Location

Location
Mallard Prospect
Easting
538077.14
Northing
6310973.22
CRS
UTM NAD83 Zone 19N
Elevation
284.68 m
Azimuth
235 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.4% Nb2O5, from 203.9m (EC10-033)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-033Ashram · fluorsparGrade: 38.8Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-033
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
38.8
Grade Unit
%
Intercept
5 m
From
203.9 m
To
208.9 m
Hole Depth
353.1 m
Intercept Depth
203.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-033:203.9-208.9

Location

Location
Mallard Prospect
Easting
538077.14
Northing
6310973.22
CRS
UTM NAD83 Zone 19N
Elevation
284.68 m
Azimuth
235 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar sub-intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • Very high fluorspar grade
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“5.0m @ 38.8% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 38.8% CaF2 is exceptionally high.

Evidence · text

“38.8% CaF2”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-033Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-033
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.3
Grade Unit
%
Intercept
5 m
From
203.9 m
To
208.9 m
Hole Depth
353.1 m
Intercept Depth
203.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-033:203.9-208.9

Location

Location
Mallard Prospect
Easting
538077.14
Northing
6310973.22
CRS
UTM NAD83 Zone 19N
Elevation
284.68 m
Azimuth
235 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium sub-intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.3% Nb2O5”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · fluorsparGrade: 21.7Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-040
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
21.7
Grade Unit
%
Intercept
29 m
From
275 m
To
304 m
Hole Depth
344.4 m
Intercept Depth
275 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-040:275-304

Location

Location
Mallard Prospect
Easting
538113.56
Northing
6311004.45
CRS
UTM NAD83 Zone 19N
Elevation
285.68 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • High fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“29.0m @ 21.7% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · niobiumGrade: 0.2Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-040
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.2
Grade Unit
%
Intercept
29 m
From
275 m
To
304 m
Hole Depth
344.4 m
Intercept Depth
275 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-040:275-304

Location

Location
Mallard Prospect
Easting
538113.56
Northing
6311004.45
CRS
UTM NAD83 Zone 19N
Elevation
285.68 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.2% Nb2O5 from 275.0m (EC10-040)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · fluorsparGrade: 39.8Grade Unit: %Intercept: 6.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-040
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
39.8
Grade Unit
%
Intercept
6.6 m
From
275 m
To
281.6 m
Hole Depth
344.4 m
Intercept Depth
275 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-040:275-281.6

Location

Location
Mallard Prospect
Easting
538113.56
Northing
6311004.45
CRS
UTM NAD83 Zone 19N
Elevation
285.68 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Exceptionally high-grade fluorspar sub-intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • Exceptionally high fluorspar grade
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“6.6m @ 39.8% CaF2”

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The fluorspar grade of 39.8% CaF2 is exceptionally high.

Evidence · text

“39.8% CaF2”

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 6.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-040
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.3
Grade Unit
%
Intercept
6.6 m
From
275 m
To
281.6 m
Hole Depth
344.4 m
Intercept Depth
275 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-040:275-281.6

Location

Location
Mallard Prospect
Easting
538113.56
Northing
6311004.45
CRS
UTM NAD83 Zone 19N
Elevation
285.68 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium sub-intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.3% Nb2O5”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-209Ashram · fluorsparGrade: 35.8Grade Unit: %Intercept: 24.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC24-209
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
35.8
Grade Unit
%
Intercept
24.8 m
From
221.7 m
To
246.5 m
Hole Depth
316.86 m
Intercept Depth
221.7 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC24-209:221.7-246.5

Location

Location
Mallard Prospect
Easting
538102.96
Northing
6310977.84
CRS
UTM NAD83 Zone 19N
Elevation
285.19 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • Very high fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“24.8 m @ 35.8% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 35.8% CaF2 is exceptionally high.

Evidence · text

“35.8% CaF2”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-209Ashram · niobiumGrade: 0.4Grade Unit: %Intercept: 24.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC24-209
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.4
Grade Unit
%
Intercept
24.8 m
From
221.7 m
To
246.5 m
Hole Depth
316.86 m
Intercept Depth
221.7 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC24-209:221.7-246.5

Location

Location
Mallard Prospect
Easting
538102.96
Northing
6310977.84
CRS
UTM NAD83 Zone 19N
Elevation
285.19 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.4% Nb2O5, from 221.7m (EC24-209)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-041Ashram · fluorsparGrade: 21.7Grade Unit: %Intercept: 14.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-041
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
21.7
Grade Unit
%
Intercept
14.3 m
From
249 m
To
263.3 m
Hole Depth
344.35 m
Intercept Depth
249 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-041:249-263.3

Location

Location
Mallard Prospect
Easting
538113.87
Northing
6311004.7
CRS
UTM NAD83 Zone 19N
Elevation
285.76 m
Azimuth
230 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • High fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“14.3m @ 21.7% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-041Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 14.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC10-041
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.3
Grade Unit
%
Intercept
14.3 m
From
249 m
To
263.3 m
Hole Depth
344.35 m
Intercept Depth
249 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC10-041:249-263.3

Location

Location
Mallard Prospect
Easting
538113.87
Northing
6311004.7
CRS
UTM NAD83 Zone 19N
Elevation
285.76 m
Azimuth
230 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2010-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.3% Nb2O5 from 249.0m (EC10-041)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-015Ashram · fluorsparGrade: 33Grade Unit: %Intercept: 13.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC08-015
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
33
Grade Unit
%
Intercept
13.8 m
From
187.8 m
To
201.6 m
Hole Depth
203.3 m
Intercept Depth
187.8 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC08-015:187.8-201.6

Location

Location
Mallard Prospect
Easting
538013.09
Northing
6310965.5
CRS
UTM NAD83 Zone 19N
Elevation
284.78 m
Azimuth
230 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2008-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • Very high fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“13.8 m @ 33.0% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 33.0% CaF2 is exceptionally high.

Evidence · text

“33.0% CaF2”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-015Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 13.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC08-015
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.3
Grade Unit
%
Intercept
13.8 m
From
187.8 m
To
201.6 m
Hole Depth
203.3 m
Intercept Depth
187.8 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC08-015:187.8-201.6

Location

Location
Mallard Prospect
Easting
538013.09
Northing
6310965.5
CRS
UTM NAD83 Zone 19N
Elevation
284.78 m
Azimuth
230 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2008-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.3% Nb2O5, from 187.8m (EC08-015)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-016Ashram · fluorsparGrade: 31.6Grade Unit: %Intercept: 20.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC08-016
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
31.6
Grade Unit
%
Intercept
20.8 m
From
202.4 m
To
223.2 m
Hole Depth
275.14 m
Intercept Depth
202.4 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC08-016:202.4-223.2

Location

Location
Mallard Prospect
Easting
538086.29
Northing
6311028.99
CRS
UTM NAD83 Zone 19N
Elevation
285.36 m
Azimuth
235 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2008-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • Very high fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“20.8 m @ 31.6% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 31.6% CaF2 is exceptionally high.

Evidence · text

“31.6% CaF2”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-016Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 20.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC08-016
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.3
Grade Unit
%
Intercept
20.8 m
From
202.4 m
To
223.2 m
Hole Depth
275.14 m
Intercept Depth
202.4 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC08-016:202.4-223.2

Location

Location
Mallard Prospect
Easting
538086.29
Northing
6311028.99
CRS
UTM NAD83 Zone 19N
Elevation
285.36 m
Azimuth
235 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2008-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.3% Nb2O5, from 202.4m (EC08-016)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · fluorsparGrade: 25.8Grade Unit: %Intercept: 9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC24-211
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
25.8
Grade Unit
%
Intercept
9 m
From
201.9 m
To
210.9 m
Hole Depth
366 m
Intercept Depth
201.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC24-211:201.9-210.9

Location

Location
Mallard Prospect
Easting
538066.29
Northing
6311011.48
CRS
UTM NAD83 Zone 19N
Elevation
285.13 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • High fluorspar grade
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“9.0 m @ 25.8% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · niobiumGrade: 0.4Grade Unit: %Intercept: 9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC24-211
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.4
Grade Unit
%
Intercept
9 m
From
201.9 m
To
210.9 m
Hole Depth
366 m
Intercept Depth
201.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC24-211:201.9-210.9

Location

Location
Mallard Prospect
Easting
538066.29
Northing
6311011.48
CRS
UTM NAD83 Zone 19N
Elevation
285.13 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.4% Nb2O5, from 201.9m (EC24-211)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · fluorsparGrade: 38.5Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC24-211
Project
Ashram
Commodity
fluorspar
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
38.5
Grade Unit
%
Intercept
10.9 m
From
275.7 m
To
286.6 m
Hole Depth
366 m
Intercept Depth
201.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC24-211:275.7-286.6

Location

Location
Mallard Prospect
Easting
538066.29
Northing
6311011.48
CRS
UTM NAD83 Zone 19N
Elevation
285.13 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

Positive factors

  • Very high fluorspar grade
  • Significant intercept length
  • Polymetallic nature with niobium
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“10.9 m @ 38.5% CaF2”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 38.5% CaF2 is exceptionally high.

Evidence · text

“38.5% CaF2”

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · niobiumGrade: 0.2Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
EC24-211
Project
Ashram
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
MRZL

Geometry

Grade
0.2
Grade Unit
%
Intercept
10.9 m
From
275.7 m
To
286.6 m
Hole Depth
366 m
Intercept Depth
201.9 m

Classification

Deposit Type
other
Program
exploration
Sample Type
drill
Group ID
EC24-211:275.7-286.6

Location

Location
Mallard Prospect
Easting
538066.29
Northing
6311011.48
CRS
UTM NAD83 Zone 19N
Elevation
285.13 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2024-01-01T00:00:00.000Z

Dates

Event date
2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

Positive factors

  • Polymetallic nature with fluorspar
  • QA/QC disclosed and lab certified

Negative factors

  • Historical data
  • Apparent width only
  • Cut-off grade undisclosed

Evidence · text

“0.2% Nb2O5, from 275.7m (EC24-211)”

Tags used in scoring

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

“The reported results are derived from previously disclosed historical exploration results.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

“True widths are not reported but drilling is believed to provide representative intersections.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

“No specific grade cap or cut-off was used during grade width calculations.”

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QA/QC DisclosedRejected · positive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.