High-Grade Fluorspar Identified at the Ashram Project's Mallard Prospect
Original announcement by tmx on
- Company
- Mont Royal Resources Ltd
- Ticker
- MRZL
- Exchange
- TSX
- Region
- Québec, Canada
- Primary commodity
- Fluorspar
- Secondary commodities
- Niobium
- Document categories
- Drill results
- Extracted
- 2026-09-18 10:51:22 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Mont Royal Resources has announced high-grade fluorspar results from historical drilling at its Mallard Prospect, part of the Ashram Project in Québec, Canada. Re-interpretation of previous niobium-focused drill holes revealed significant fluorspar intercepts, including up to 39.8% CaF2. The company plans further exploration to expand and delineate these high-grade zones, highlighting the strategic importance of fluorspar in global markets.
Reasoning: The document reports high-grade fluorspar intercepts from historical drilling at the Mallard Prospect, re-interpreting previous niobium-focused work. The results confirm significant fluorspar potential in a strategically important critical mineral, supported by robust QA/QC and QP sign-off, despite being historical and lacking true width information.
Positive factors
- High-grade fluorspar intercepts confirmed from historical drilling
- Strategic importance of fluorspar as a critical mineral
- Potential for future co-development with nearby Ashram Deposit
- Detailed QA/QC disclosure and QP sign-off
Negative factors
- Results are historical, not new drilling
- True width of mineralization is not known
- No specific cut-off grade used for compositing
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 20
Extracted facts
Stored fact records: 20. Some facts used in scoring do not have a stored record.
Drill Results (20)
EC10-033Ashram · fluorsparGrade: 26.1Grade Unit: %Intercept: 32.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-033
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 26.1
- Grade Unit
- %
- Intercept
- 32.4 m
- From
- 203.9 m
- To
- 236.3 m
- Hole Depth
- 353.1 m
- Intercept Depth
- 203.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-033:203.9-236.3
Location
- Location
- Mallard Prospect
- Easting
- 538077.14
- Northing
- 6310973.22
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 284.68 m
- Azimuth
- 235 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- High fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“32.4m @ 26.1% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-033Ashram · niobiumGrade: 0.4Grade Unit: %Intercept: 32.4 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-033
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 32.4 m
- From
- 203.9 m
- To
- 236.3 m
- Hole Depth
- 353.1 m
- Intercept Depth
- 203.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-033:203.9-236.3
Location
- Location
- Mallard Prospect
- Easting
- 538077.14
- Northing
- 6310973.22
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 284.68 m
- Azimuth
- 235 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.4% Nb2O5, from 203.9m (EC10-033)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-033Ashram · fluorsparGrade: 38.8Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-033
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 38.8
- Grade Unit
- %
- Intercept
- 5 m
- From
- 203.9 m
- To
- 208.9 m
- Hole Depth
- 353.1 m
- Intercept Depth
- 203.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-033:203.9-208.9
Location
- Location
- Mallard Prospect
- Easting
- 538077.14
- Northing
- 6310973.22
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 284.68 m
- Azimuth
- 235 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Very high-grade fluorspar sub-intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- Very high fluorspar grade
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“5.0m @ 38.8% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The fluorspar grade of 38.8% CaF2 is exceptionally high.
Evidence · text
“38.8% CaF2”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-033Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 5 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-033
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 5 m
- From
- 203.9 m
- To
- 208.9 m
- Hole Depth
- 353.1 m
- Intercept Depth
- 203.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-033:203.9-208.9
Location
- Location
- Mallard Prospect
- Easting
- 538077.14
- Northing
- 6310973.22
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 284.68 m
- Azimuth
- 235 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium sub-intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.3% Nb2O5”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · fluorsparGrade: 21.7Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-040
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 21.7
- Grade Unit
- %
- Intercept
- 29 m
- From
- 275 m
- To
- 304 m
- Hole Depth
- 344.4 m
- Intercept Depth
- 275 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-040:275-304
Location
- Location
- Mallard Prospect
- Easting
- 538113.56
- Northing
- 6311004.45
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.68 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- High fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“29.0m @ 21.7% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · niobiumGrade: 0.2Grade Unit: %Intercept: 29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-040
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 29 m
- From
- 275 m
- To
- 304 m
- Hole Depth
- 344.4 m
- Intercept Depth
- 275 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-040:275-304
Location
- Location
- Mallard Prospect
- Easting
- 538113.56
- Northing
- 6311004.45
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.68 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.2% Nb2O5 from 275.0m (EC10-040)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · fluorsparGrade: 39.8Grade Unit: %Intercept: 6.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-040
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 39.8
- Grade Unit
- %
- Intercept
- 6.6 m
- From
- 275 m
- To
- 281.6 m
- Hole Depth
- 344.4 m
- Intercept Depth
- 275 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-040:275-281.6
Location
- Location
- Mallard Prospect
- Easting
- 538113.56
- Northing
- 6311004.45
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.68 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Exceptionally high-grade fluorspar sub-intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- Exceptionally high fluorspar grade
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“6.6m @ 39.8% CaF2”
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The fluorspar grade of 39.8% CaF2 is exceptionally high.
Evidence · text
“39.8% CaF2”
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-040Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 6.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-040
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 6.6 m
- From
- 275 m
- To
- 281.6 m
- Hole Depth
- 344.4 m
- Intercept Depth
- 275 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-040:275-281.6
Location
- Location
- Mallard Prospect
- Easting
- 538113.56
- Northing
- 6311004.45
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.68 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium sub-intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.3% Nb2O5”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-209Ashram · fluorsparGrade: 35.8Grade Unit: %Intercept: 24.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC24-209
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 35.8
- Grade Unit
- %
- Intercept
- 24.8 m
- From
- 221.7 m
- To
- 246.5 m
- Hole Depth
- 316.86 m
- Intercept Depth
- 221.7 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC24-209:221.7-246.5
Location
- Location
- Mallard Prospect
- Easting
- 538102.96
- Northing
- 6310977.84
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.19 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- Very high fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“24.8 m @ 35.8% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The fluorspar grade of 35.8% CaF2 is exceptionally high.
Evidence · text
“35.8% CaF2”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-209Ashram · niobiumGrade: 0.4Grade Unit: %Intercept: 24.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC24-209
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 24.8 m
- From
- 221.7 m
- To
- 246.5 m
- Hole Depth
- 316.86 m
- Intercept Depth
- 221.7 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC24-209:221.7-246.5
Location
- Location
- Mallard Prospect
- Easting
- 538102.96
- Northing
- 6310977.84
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.19 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.4% Nb2O5, from 221.7m (EC24-209)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-041Ashram · fluorsparGrade: 21.7Grade Unit: %Intercept: 14.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-041
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 21.7
- Grade Unit
- %
- Intercept
- 14.3 m
- From
- 249 m
- To
- 263.3 m
- Hole Depth
- 344.35 m
- Intercept Depth
- 249 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-041:249-263.3
Location
- Location
- Mallard Prospect
- Easting
- 538113.87
- Northing
- 6311004.7
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.76 m
- Azimuth
- 230 °
- Dip
- -75 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- High fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“14.3m @ 21.7% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC10-041Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 14.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC10-041
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 14.3 m
- From
- 249 m
- To
- 263.3 m
- Hole Depth
- 344.35 m
- Intercept Depth
- 249 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC10-041:249-263.3
Location
- Location
- Mallard Prospect
- Easting
- 538113.87
- Northing
- 6311004.7
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.76 m
- Azimuth
- 230 °
- Dip
- -75 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2010-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.3% Nb2O5 from 249.0m (EC10-041)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-015Ashram · fluorsparGrade: 33Grade Unit: %Intercept: 13.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC08-015
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 33
- Grade Unit
- %
- Intercept
- 13.8 m
- From
- 187.8 m
- To
- 201.6 m
- Hole Depth
- 203.3 m
- Intercept Depth
- 187.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC08-015:187.8-201.6
Location
- Location
- Mallard Prospect
- Easting
- 538013.09
- Northing
- 6310965.5
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 284.78 m
- Azimuth
- 230 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2008-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- Very high fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“13.8 m @ 33.0% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The fluorspar grade of 33.0% CaF2 is exceptionally high.
Evidence · text
“33.0% CaF2”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-015Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 13.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC08-015
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 13.8 m
- From
- 187.8 m
- To
- 201.6 m
- Hole Depth
- 203.3 m
- Intercept Depth
- 187.8 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC08-015:187.8-201.6
Location
- Location
- Mallard Prospect
- Easting
- 538013.09
- Northing
- 6310965.5
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 284.78 m
- Azimuth
- 230 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2008-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.3% Nb2O5, from 187.8m (EC08-015)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-016Ashram · fluorsparGrade: 31.6Grade Unit: %Intercept: 20.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC08-016
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 31.6
- Grade Unit
- %
- Intercept
- 20.8 m
- From
- 202.4 m
- To
- 223.2 m
- Hole Depth
- 275.14 m
- Intercept Depth
- 202.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC08-016:202.4-223.2
Location
- Location
- Mallard Prospect
- Easting
- 538086.29
- Northing
- 6311028.99
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.36 m
- Azimuth
- 235 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2008-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- Very high fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“20.8 m @ 31.6% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The fluorspar grade of 31.6% CaF2 is exceptionally high.
Evidence · text
“31.6% CaF2”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC08-016Ashram · niobiumGrade: 0.3Grade Unit: %Intercept: 20.8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC08-016
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 20.8 m
- From
- 202.4 m
- To
- 223.2 m
- Hole Depth
- 275.14 m
- Intercept Depth
- 202.4 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC08-016:202.4-223.2
Location
- Location
- Mallard Prospect
- Easting
- 538086.29
- Northing
- 6311028.99
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.36 m
- Azimuth
- 235 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2008-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.3% Nb2O5, from 202.4m (EC08-016)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · fluorsparGrade: 25.8Grade Unit: %Intercept: 9 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC24-211
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 25.8
- Grade Unit
- %
- Intercept
- 9 m
- From
- 201.9 m
- To
- 210.9 m
- Hole Depth
- 366 m
- Intercept Depth
- 201.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC24-211:201.9-210.9
Location
- Location
- Mallard Prospect
- Easting
- 538066.29
- Northing
- 6311011.48
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.13 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- High fluorspar grade
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“9.0 m @ 25.8% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · niobiumGrade: 0.4Grade Unit: %Intercept: 9 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC24-211
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 9 m
- From
- 201.9 m
- To
- 210.9 m
- Hole Depth
- 366 m
- Intercept Depth
- 201.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC24-211:201.9-210.9
Location
- Location
- Mallard Prospect
- Easting
- 538066.29
- Northing
- 6311011.48
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.13 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.4% Nb2O5, from 201.9m (EC24-211)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · fluorsparGrade: 38.5Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC24-211
- Project
- Ashram
- Commodity
- fluorspar
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 38.5
- Grade Unit
- %
- Intercept
- 10.9 m
- From
- 275.7 m
- To
- 286.6 m
- Hole Depth
- 366 m
- Intercept Depth
- 201.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC24-211:275.7-286.6
Location
- Location
- Mallard Prospect
- Easting
- 538066.29
- Northing
- 6311011.48
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.13 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.
Positive factors
- Very high fluorspar grade
- Significant intercept length
- Polymetallic nature with niobium
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“10.9 m @ 38.5% CaF2”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: The fluorspar grade of 38.5% CaF2 is exceptionally high.
Evidence · text
“38.5% CaF2”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
EC24-211Ashram · niobiumGrade: 0.2Grade Unit: %Intercept: 10.9 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- EC24-211
- Project
- Ashram
- Commodity
- niobium
- Region
- canada_qc
- Reported Region
- canada_qc
- Ticker
- MRZL
Geometry
- Grade
- 0.2
- Grade Unit
- %
- Intercept
- 10.9 m
- From
- 275.7 m
- To
- 286.6 m
- Hole Depth
- 366 m
- Intercept Depth
- 201.9 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- EC24-211:275.7-286.6
Location
- Location
- Mallard Prospect
- Easting
- 538066.29
- Northing
- 6311011.48
- CRS
- UTM NAD83 Zone 19N
- Elevation
- 285.13 m
- Azimuth
- 230 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Actlabs
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2024-01-01T00:00:00.000Z
Dates
- Event date
- 2026-05-27T00:00:00.000Z
Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.
Positive factors
- Polymetallic nature with fluorspar
- QA/QC disclosed and lab certified
Negative factors
- Historical data
- Apparent width only
- Cut-off grade undisclosed
Evidence · text
“0.2% Nb2O5, from 275.7m (EC24-211)”
Tags used in scoring
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: The reported results are derived from previously disclosed historical exploration results.
Evidence · text
“The reported results are derived from previously disclosed historical exploration results.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: True widths are not reported but drilling is believed to provide representative intersections.
Evidence · text
“True widths are not reported but drilling is believed to provide representative intersections.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: No specific grade cap or cut-off was used during grade width calculations.
Evidence · text
“No specific grade cap or cut-off was used during grade width calculations.”
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.
Evidence · text
“Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.”
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.