# High-Grade Fluorspar Identified at the Ashram Project's Mallard Prospect

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8

Original source: https://money.tmx.com/en/quote/MRZL/news/4825067802218227/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect

Publisher: tmx

Original announcement: 2026-05-27T02:25:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Mont Royal Resources Ltd

- Ticker: MRZL

- Exchange: TSX

- Region: Québec, Canada

- Primary commodity: Fluorspar

- Secondary commodities: Niobium

- Document categories: Drill results

- Extracted: 2026-09-18 10:51:22 UTC

Narrative sentiment: 0.70 · Bullish

## Minestarters Atlas summary

Mont Royal Resources has announced high-grade fluorspar results from historical drilling at its Mallard Prospect, part of the Ashram Project in Québec, Canada. Re-interpretation of previous niobium-focused drill holes revealed significant fluorspar intercepts, including up to 39.8% CaF2. The company plans further exploration to expand and delineate these high-grade zones, highlighting the strategic importance of fluorspar in global markets.

Reasoning: The document reports high-grade fluorspar intercepts from historical drilling at the Mallard Prospect, re-interpreting previous niobium-focused work. The results confirm significant fluorspar potential in a strategically important critical mineral, supported by robust QA/QC and QP sign-off, despite being historical and lacking true width information.

- Positive factor: High-grade fluorspar intercepts confirmed from historical drilling

- Positive factor: Strategic importance of fluorspar as a critical mineral

- Positive factor: Potential for future co-development with nearby Ashram Deposit

- Positive factor: Detailed QA/QC disclosure and QP sign-off

- Negative factor: Results are historical, not new drilling

- Negative factor: True width of mineralization is not known

- Negative factor: No specific cut-off grade used for compositing

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 20

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 20. Some facts used in scoring do not have a stored record.

## Drill Results (20)

### EC10-033

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-0)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-033
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 26.1
- Grade Unit: %
- Intercept: 32.4 m
- From: 203.9 m
- To: 236.3 m
- Hole Depth: 353.1 m
- Intercept Depth: 203.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-033:203.9-236.3

#### Location

- Location: Mallard Prospect
- Easting: 538077.14
- Northing: 6310973.22
- CRS: UTM NAD83 Zone 19N
- Elevation: 284.68 m
- Azimuth: 235 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: High fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 32.4m @ 26.1% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-033

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-1)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-033
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 32.4 m
- From: 203.9 m
- To: 236.3 m
- Hole Depth: 353.1 m
- Intercept Depth: 203.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-033:203.9-236.3

#### Location

- Location: Mallard Prospect
- Easting: 538077.14
- Northing: 6310973.22
- CRS: UTM NAD83 Zone 19N
- Elevation: 284.68 m
- Azimuth: 235 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.4% Nb2O5, from 203.9m \(EC10-033\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-033

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-2)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-033
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 38.8
- Grade Unit: %
- Intercept: 5 m
- From: 203.9 m
- To: 208.9 m
- Hole Depth: 353.1 m
- Intercept Depth: 203.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-033:203.9-208.9

#### Location

- Location: Mallard Prospect
- Easting: 538077.14
- Northing: 6310973.22
- CRS: UTM NAD83 Zone 19N
- Elevation: 284.68 m
- Azimuth: 235 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar sub-intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: Very high fluorspar grade

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 5.0m @ 38.8% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 38.8% CaF2 is exceptionally high.

Evidence · text

> 38.8% CaF2

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-033

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-3)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-033
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 5 m
- From: 203.9 m
- To: 208.9 m
- Hole Depth: 353.1 m
- Intercept Depth: 203.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-033:203.9-208.9

#### Location

- Location: Mallard Prospect
- Easting: 538077.14
- Northing: 6310973.22
- CRS: UTM NAD83 Zone 19N
- Elevation: 284.68 m
- Azimuth: 235 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium sub-intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.3% Nb2O5

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-040

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-4)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-040
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 21.7
- Grade Unit: %
- Intercept: 29 m
- From: 275 m
- To: 304 m
- Hole Depth: 344.4 m
- Intercept Depth: 275 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-040:275-304

#### Location

- Location: Mallard Prospect
- Easting: 538113.56
- Northing: 6311004.45
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.68 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: High fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 29.0m @ 21.7% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-040

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-5)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-040
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 29 m
- From: 275 m
- To: 304 m
- Hole Depth: 344.4 m
- Intercept Depth: 275 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-040:275-304

#### Location

- Location: Mallard Prospect
- Easting: 538113.56
- Northing: 6311004.45
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.68 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.2% Nb2O5 from 275.0m \(EC10-040\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-040

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-6)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-040
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 39.8
- Grade Unit: %
- Intercept: 6.6 m
- From: 275 m
- To: 281.6 m
- Hole Depth: 344.4 m
- Intercept Depth: 275 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-040:275-281.6

#### Location

- Location: Mallard Prospect
- Easting: 538113.56
- Northing: 6311004.45
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.68 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Exceptionally high-grade fluorspar sub-intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: Exceptionally high fluorspar grade

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 6.6m @ 39.8% CaF2

#### Tags used in scoring

**Bonanza Intercept**

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The fluorspar grade of 39.8% CaF2 is exceptionally high.

Evidence · text

> 39.8% CaF2

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-040

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-7)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-040
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 6.6 m
- From: 275 m
- To: 281.6 m
- Hole Depth: 344.4 m
- Intercept Depth: 275 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-040:275-281.6

#### Location

- Location: Mallard Prospect
- Easting: 538113.56
- Northing: 6311004.45
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.68 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium sub-intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.3% Nb2O5

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC24-209

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-8)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC24-209
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 35.8
- Grade Unit: %
- Intercept: 24.8 m
- From: 221.7 m
- To: 246.5 m
- Hole Depth: 316.86 m
- Intercept Depth: 221.7 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC24-209:221.7-246.5

#### Location

- Location: Mallard Prospect
- Easting: 538102.96
- Northing: 6310977.84
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.19 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2024-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: Very high fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 24.8 m @ 35.8% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 35.8% CaF2 is exceptionally high.

Evidence · text

> 35.8% CaF2

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC24-209

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-9)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC24-209
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 24.8 m
- From: 221.7 m
- To: 246.5 m
- Hole Depth: 316.86 m
- Intercept Depth: 221.7 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC24-209:221.7-246.5

#### Location

- Location: Mallard Prospect
- Easting: 538102.96
- Northing: 6310977.84
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.19 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2024-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.4% Nb2O5, from 221.7m \(EC24-209\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-041

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-10)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-041
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 21.7
- Grade Unit: %
- Intercept: 14.3 m
- From: 249 m
- To: 263.3 m
- Hole Depth: 344.35 m
- Intercept Depth: 249 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-041:249-263.3

#### Location

- Location: Mallard Prospect
- Easting: 538113.87
- Northing: 6311004.7
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.76 m
- Azimuth: 230 °
- Dip: -75 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: High fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 14.3m @ 21.7% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC10-041

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-11)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC10-041
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 14.3 m
- From: 249 m
- To: 263.3 m
- Hole Depth: 344.35 m
- Intercept Depth: 249 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC10-041:249-263.3

#### Location

- Location: Mallard Prospect
- Easting: 538113.87
- Northing: 6311004.7
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.76 m
- Azimuth: 230 °
- Dip: -75 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2010-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.3% Nb2O5 from 249.0m \(EC10-041\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC08-015

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-12)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC08-015
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 33
- Grade Unit: %
- Intercept: 13.8 m
- From: 187.8 m
- To: 201.6 m
- Hole Depth: 203.3 m
- Intercept Depth: 187.8 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC08-015:187.8-201.6

#### Location

- Location: Mallard Prospect
- Easting: 538013.09
- Northing: 6310965.5
- CRS: UTM NAD83 Zone 19N
- Elevation: 284.78 m
- Azimuth: 230 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2008-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: Very high fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 13.8 m @ 33.0% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 33.0% CaF2 is exceptionally high.

Evidence · text

> 33.0% CaF2

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC08-015

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-13)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC08-015
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 13.8 m
- From: 187.8 m
- To: 201.6 m
- Hole Depth: 203.3 m
- Intercept Depth: 187.8 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC08-015:187.8-201.6

#### Location

- Location: Mallard Prospect
- Easting: 538013.09
- Northing: 6310965.5
- CRS: UTM NAD83 Zone 19N
- Elevation: 284.78 m
- Azimuth: 230 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2008-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.3% Nb2O5, from 187.8m \(EC08-015\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC08-016

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-14)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC08-016
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 31.6
- Grade Unit: %
- Intercept: 20.8 m
- From: 202.4 m
- To: 223.2 m
- Hole Depth: 275.14 m
- Intercept Depth: 202.4 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC08-016:202.4-223.2

#### Location

- Location: Mallard Prospect
- Easting: 538086.29
- Northing: 6311028.99
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.36 m
- Azimuth: 235 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2008-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: Very high fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 20.8 m @ 31.6% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 31.6% CaF2 is exceptionally high.

Evidence · text

> 31.6% CaF2

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC08-016

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-15)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC08-016
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 20.8 m
- From: 202.4 m
- To: 223.2 m
- Hole Depth: 275.14 m
- Intercept Depth: 202.4 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC08-016:202.4-223.2

#### Location

- Location: Mallard Prospect
- Easting: 538086.29
- Northing: 6311028.99
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.36 m
- Azimuth: 235 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2008-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.3% Nb2O5, from 202.4m \(EC08-016\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC24-211

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-16)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC24-211
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 25.8
- Grade Unit: %
- Intercept: 9 m
- From: 201.9 m
- To: 210.9 m
- Hole Depth: 366 m
- Intercept Depth: 201.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC24-211:201.9-210.9

#### Location

- Location: Mallard Prospect
- Easting: 538066.29
- Northing: 6311011.48
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.13 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2024-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: High-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: High fluorspar grade

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 9.0 m @ 25.8% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC24-211

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-17)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC24-211
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 9 m
- From: 201.9 m
- To: 210.9 m
- Hole Depth: 366 m
- Intercept Depth: 201.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC24-211:201.9-210.9

#### Location

- Location: Mallard Prospect
- Easting: 538066.29
- Northing: 6311011.48
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.13 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2024-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.4% Nb2O5, from 201.9m \(EC24-211\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC24-211

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-18)

Ashram · fluorspar

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC24-211
- Project: Ashram
- Commodity: fluorspar
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 38.5
- Grade Unit: %
- Intercept: 10.9 m
- From: 275.7 m
- To: 286.6 m
- Hole Depth: 366 m
- Intercept Depth: 201.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC24-211:275.7-286.6

#### Location

- Location: Mallard Prospect
- Easting: 538066.29
- Northing: 6311011.48
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.13 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2024-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Very high-grade fluorspar intercept from historical drilling, indicating significant fluorspar potential, but true width is not known and cut-off is undisclosed.

- Positive factor: Very high fluorspar grade

- Positive factor: Significant intercept length

- Positive factor: Polymetallic nature with niobium

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 10.9 m @ 38.5% CaF2

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**Bonanza Intercept** — Rejected; excluded from scoring

Polarity: positive

Definition: Exceptionally high-grade zone, well above the deposit-type norm.

Reason: The fluorspar grade of 38.5% CaF2 is exceptionally high.

Evidence · text

> 38.5% CaF2

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

### EC24-211

[Link to this fact](https://atlas-extractions.minestarters.com/news/high-grade-fluorspar-identified-at-the-ashram-project-s-mallard-prospect--5dac0c0c-1e79-48c2-b83d-71c1b9b106a8#fact-drill-facts-19)

Ashram · niobium

Historical result

Needs review: historical\_restatement

#### Identity

- Hole ID: EC24-211
- Project: Ashram
- Commodity: niobium
- Region: canada\_qc
- Reported Region: canada\_qc
- Ticker: MRZL

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 10.9 m
- From: 275.7 m
- To: 286.6 m
- Hole Depth: 366 m
- Intercept Depth: 201.9 m

#### Classification

- Deposit Type: other
- Program: exploration
- Sample Type: drill
- Group ID: EC24-211:275.7-286.6

#### Location

- Location: Mallard Prospect
- Easting: 538066.29
- Northing: 6311011.48
- CRS: UTM NAD83 Zone 19N
- Elevation: 285.13 m
- Azimuth: 230 °
- Dip: -45 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: Actlabs
- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: Yes
- Review Reason: historical\_restatement
- Interp. Status: scored
- Historical: Yes
- Historical Source Date: 2024-01-01T00:00:00.000Z

#### Dates

- Event date: 2026-05-27T00:00:00.000Z

Reasoning: Niobium intercept from historical drilling, part of a polymetallic system, but true width is not known and cut-off is undisclosed.

- Positive factor: Polymetallic nature with fluorspar

- Positive factor: QA/QC disclosed and lab certified

- Negative factor: Historical data

- Negative factor: Apparent width only

- Negative factor: Cut-off grade undisclosed

Evidence · text

> 0.2% Nb2O5, from 275.7m \(EC24-211\)

#### Tags used in scoring

**Stale Data Re-release**

Polarity: negative

Definition: Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: The reported results are derived from previously disclosed historical exploration results.

Evidence · text

> The reported results are derived from previously disclosed historical exploration results.

**Apparent Width Only**

Polarity: negative

Definition: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: True widths are not reported but drilling is believed to provide representative intersections.

Evidence · text

> True widths are not reported but drilling is believed to provide representative intersections.

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: No specific grade cap or cut-off was used during grade width calculations.

Evidence · text

> No specific grade cap or cut-off was used during grade width calculations.

#### Rejected tags

**QA/QC Disclosed** — Rejected; excluded from scoring

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Reason: The document includes a detailed 'Sampling Techniques and Data' section outlining QA/QC procedures, lab accreditation, and QP sign-off.

Evidence · text

> Sampling procedures follow industry-standard protocols, including QA/QC measures. Core samples collected from drill holes were shipped to Actlabs in Ancaster, ON, for sample preparation. The Actlabs Ancaster facility is an accredited laboratory under ISO/IEC 17025 standards.

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.