Highlander Silver Reports First Drill Results from Bonita Open Pit Target, Including High Grades over Broad Widths from Near Surface in Every Hole

Original announcement by tmx on

Company
Highlander Silver Corp.
Ticker
HSLV
Exchange
TSX
Region
Central Peru
Primary commodity
Gold
Secondary commodities
Silver
Document categories
Drill results
Extracted
2026-09-12 07:27:52 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Highlander Silver reported initial drill results from seven holes at its Bonita Open Pit Target, part of the San Luis gold-silver project in Central Peru. All holes intersected high-grade gold-silver mineralization from near surface over broad widths, including 14.5m of 3.70 g/t Au and 17.47 g/t Ag in BOD-003, and 16.9m of 4.42 g/t Au with a high-grade core of 3.3m at 15.15 g/t Au in BOD-004. The program successfully stepped out from historical drilling, confirming consistent mineralization and indicating potential for an open-pit operation.

Reasoning: The first drill results from the Bonita Open Pit Target show consistent broad intersections of high-grade gold-silver mineralization from near surface in step-out drilling, significantly expanding the known mineralized footprint. The presence of multiple bonanza-grade gold intercepts (e.g., 15.15 g/t Au over 3.3m) and wide mineralized zones (e.g., 47.8m at 1.87 g/t Au) is highly positive for the project's open-pit potential. While true widths are not yet modelled, the overall results are very encouraging for early-stage exploration.

Positive factors

  • High-grade gold intercepts (up to 15.15 g/t Au) over significant widths (up to 47.8m)
  • Mineralization encountered near surface in every hole, indicating potential for open-pit mining
  • Successful step-out drilling extends known mineralization from historical holes
  • Comprehensive QA/QC procedures disclosed, including certified lab, QP sign-off, and various control samples
  • Transparent compositing rules with stated cut-off grade and internal dilution disclosure

Negative factors

  • Intervals reported as apparent widths only, true width not yet modelled

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 42

Classification and evidence

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details QA/QC procedures including the use of ALS Peru S.A. as the laboratory, submission of field duplicates, pulp and coarse reject duplicates, and insertion of commercial standards and blanks, with sign-off by a Qualified Person.

Evidence · text

“All drilling was completed with HQ core. The drill core is split in half using a diamond saw. Core is logged by the Company's geologist on site who outlines the intervals to be sampled. The maximum sample length is 1.5 meters and lengths are adjusted according to lithological and/or mineralogical contacts. After sawing, one-half of the core is kept on site in core boxes, and the other half is submitted for analysis. Individual sample bags are sealed and placed into larger bags, which are then sealed and marked with the contents. Samples are transported by Highlander Silver personnel to ALS Peru S.A. (" ALS ") located in Lima, Peru, where they are prepared and analyzed. ALS is independent of the Company. In ALS, the entire sample is crushed to approximately 80% passing through a 2mm sieve. A 500 g fraction is pulverized. Gold concentration is determined by fire assay of a 30-gram charge with an AA finish (Au-AA23). Silver, lead, copper, and zinc, along with other elements, are analyzed by ICP utilizing a four-acid digestion (ME-ICP61). Over-limit samples for Au (10 g/t Au) follow gravitational finishing Au-GRA21 (30g sample). Over-limit samples for Ag (100 g/t Ag) follow gravitational finishing Ag-GRA21 (30g sample). The internal QA/QC program includes the submission of field duplicates (1/4 core), pulp and coarse reject duplicates, and the insertion of commercial standards and blanks (coarse and fine). Control samples account for more than 15% of the total samples sent, in addition to the laboratory's internal quality assurance programs. The Company is not aware of any drilling, sampling, recovery, or other factors that could materially affect the accuracy or reliability of the data referred to herein. The scientific and technical information, including the drillhole data, has been verified by Dr. Sergio Gelcich. This verification involves data validation and quality assurance procedures, such as reviewing logging directly in front of the core, analyzing database integrity, conducting quality assurance and quality control (QA/QC) for assays, and cross-checking the original lab certificates. Qualified Person The scientific and technical information in this press release has been reviewed and approved by Dr. Sergio Gelcich, P.Geo., Vice President, Exploration, Highlander Silver, who is a "Qualified Person" as defined in National Instrument 43-101 Standards of Disclosure for Mineral Projects.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that 'Reported intervals are apparent widths as the full geometry of the mineralized structures has not yet been fully modelled,' indicating that true widths are not provided.

Evidence · text

“Reported intervals are apparent widths as the full geometry of the mineralized structures has not yet been fully modelled.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The drilling program is described as following up on and stepping out from two historical holes (BOD-001 and BOD-002), indicating an extension of known mineralization.

Evidence · text

“The first seven holes follow up on and step out from two historical holes (BOD-001 and BOD-002)”

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: The release clearly states the compositing rules: 'composite intervals are calculated using a minimum weighted average of 0.5 g/t Au, diluted over a minimum core length that allows for internal dilution' and 'Included high-grade intercepts are reported as any consecutive interval with grades greater than 5 g/t Au'.

Evidence · text

“Assays were not capped, and composite intervals are calculated using a minimum weighted average of 0.5 g/t Au, diluted over a minimum core length that allows for internal dilution. Included high-grade intercepts are reported as any consecutive interval with grades greater than 5 g/t Au.”

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole BOD-004 returned 3.3m of 15.15 g/t Au, which significantly exceeds the 5 g/t Au exceptional threshold for open-pit gold.

Evidence · table

“15.15”

Context: 3.3

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole BOD-008 returned 13.0m of 7.11 g/t Au, which significantly exceeds the 5 g/t Au exceptional threshold for open-pit gold.

Evidence · table

“7.11”

Context: 13.0

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole BOD-009 returned 2.1m of 12.55 g/t Au, which significantly exceeds the 5 g/t Au exceptional threshold for open-pit gold.

Evidence · table

“12.55”

Context: 2.1

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Hole BOD-003 returned 4.1m of 5.34 g/t Au, which exceeds the 5 g/t Au exceptional threshold for open-pit gold.

Evidence · table

“5.34”

Context: 4.1

Extracted facts

Stored fact records: 42. Some facts used in scoring do not have a stored record.

Drill Results (42)

BOD-003San Luis · goldGrade: 0.85Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
BOD-003
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
0.85
Grade Unit
g/t
Intercept
2.2 m
From
12 m
To
14.2 m
Hole Depth
225.6 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-003:12-14.2
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
44 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A narrow, moderate-grade gold intercept from near surface in a new exploration hole.

Evidence · table

“0.85”

Context: 2.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-003San Luis · silverGrade: 12.89Grade Unit: g/tIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
BOD-003
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
12.89
Grade Unit
g/t
Intercept
2.2 m
From
12 m
To
14.2 m
Hole Depth
225.6 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-003:12-14.2
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
44 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A narrow, moderate-grade silver intercept from near surface in a new exploration hole.

Evidence · table

“12.89”

Context: 2.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-003San Luis · goldGrade: 3.7Grade Unit: g/tIntercept: 14.5 mView all details
Link to this fact

Identity

Hole ID
BOD-003
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
14.5 m
From
25.7 m
To
40.2 m
Hole Depth
225.6 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-003:25.7-40.2
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
44 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A strong gold intercept with good width and grade from near surface, contributing positively to the open-pit target.

Positive factors

  • Strong gold grade (3.70 g/t) over a significant width (14.5m) for an open-pit target
  • Intercept is near surface, enhancing open-pit potential

Evidence · table

“3.70”

Context: 14.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-003San Luis · silverGrade: 17.47Grade Unit: g/tIntercept: 14.5 mView all details
Link to this fact

Identity

Hole ID
BOD-003
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
17.47
Grade Unit
g/t
Intercept
14.5 m
From
25.7 m
To
40.2 m
Hole Depth
225.6 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-003:25.7-40.2
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
44 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept with good width, complementing the primary gold mineralization.

Positive factors

  • Moderate silver grade (17.47 g/t) over a significant width (14.5m) as a byproduct

Evidence · table

“17.47”

Context: 14.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-003San Luis · goldGrade: 5.34Grade Unit: g/tIntercept: 4.1 mView all details
Link to this fact

Identity

Hole ID
BOD-003
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
5.34
Grade Unit
g/t
Intercept
4.1 m
From
165 m
To
169.1 m
Hole Depth
225.6 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-003:165-169.1
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
44 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A high-grade gold intercept, indicating strong mineralization at depth within this hole.

Positive factors

  • Exceptional gold grade (5.34 g/t) over a moderate width (4.1m)

Evidence · table

“5.34”

Context: 4.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-003San Luis · silverGrade: 43.22Grade Unit: g/tIntercept: 4.1 mView all details
Link to this fact

Identity

Hole ID
BOD-003
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
43.22
Grade Unit
g/t
Intercept
4.1 m
From
165 m
To
169.1 m
Hole Depth
225.6 m
Intercept Depth
12 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-003:165-169.1
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
44 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A strong silver intercept, complementing the high-grade gold mineralization at depth.

Positive factors

  • Strong silver grade (43.22 g/t) over a moderate width (4.1m)

Evidence · table

“43.22”

Context: 4.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-004San Luis · goldGrade: 4.42Grade Unit: g/tIntercept: 16.9 mView all details
Link to this fact

Identity

Hole ID
BOD-004
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
4.42
Grade Unit
g/t
Intercept
16.9 m
From
24.7 m
To
41.6 m
Hole Depth
206 m
Intercept Depth
24.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-004:24.7-41.6
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
90 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A very strong gold intercept with excellent width and grade from near surface, indicating significant open-pit potential.

Positive factors

  • Strong gold grade (4.42 g/t) over a broad width (16.9m) from near surface
  • Intercept includes a bonanza-grade sub-interval

Evidence · table

“4.42”

Context: 16.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-004San Luis · silverGrade: 7.61Grade Unit: g/tIntercept: 16.9 mView all details
Link to this fact

Identity

Hole ID
BOD-004
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
7.61
Grade Unit
g/t
Intercept
16.9 m
From
24.7 m
To
41.6 m
Hole Depth
206 m
Intercept Depth
24.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-004:24.7-41.6
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
90 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept over a broad width, complementing the primary gold mineralization.

Positive factors

  • Moderate silver grade (7.61 g/t) over a broad width (16.9m)

Evidence · table

“7.61”

Context: 16.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-004San Luis · goldGrade: 15.15Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
BOD-004
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
15.15
Grade Unit
g/t
Intercept
3.3 m
From
33.7 m
To
37 m
Hole Depth
206 m
Intercept Depth
24.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-004:33.7-37
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
90 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: An exceptional bonanza-grade gold intercept, highlighting the high-grade potential of the system.

Positive factors

  • Bonanza gold grade (15.15 g/t) over a moderate width (3.3m)
  • Indicates high-grade core within a broader mineralized zone

Evidence · table

“15.15”

Context: 3.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-004San Luis · silverGrade: 14.08Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
BOD-004
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
14.08
Grade Unit
g/t
Intercept
3.3 m
From
33.7 m
To
37 m
Hole Depth
206 m
Intercept Depth
24.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-004:33.7-37
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
90 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept within the high-grade gold zone.

Positive factors

  • Moderate silver grade (14.08 g/t) over a moderate width (3.3m)

Evidence · table

“14.08”

Context: 3.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-004San Luis · goldGrade: 0.67Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
BOD-004
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
0.67
Grade Unit
g/t
Intercept
3 m
From
193.5 m
To
196.5 m
Hole Depth
206 m
Intercept Depth
24.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-004:193.5-196.5
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
90 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A narrow, moderate-grade gold intercept at depth.

Evidence · table

“0.67”

Context: 3.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-004San Luis · silverGrade: 2.55Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
BOD-004
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
2.55
Grade Unit
g/t
Intercept
3 m
From
193.5 m
To
196.5 m
Hole Depth
206 m
Intercept Depth
24.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-004:193.5-196.5
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187941
Northing
8953730
Elevation
3953 m
Azimuth
90 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A narrow, low-grade silver intercept at depth.

Evidence · table

“2.55”

Context: 3.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-005San Luis · goldGrade: 2.09Grade Unit: g/tIntercept: 11.9 mView all details
Link to this fact

Identity

Hole ID
BOD-005
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
2.09
Grade Unit
g/t
Intercept
11.9 m
From
68.7 m
To
80.6 m
Hole Depth
160.3 m
Intercept Depth
68.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-005:68.7-80.6
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187998
Northing
8953799
Elevation
3986 m
Azimuth
55 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A strong gold intercept with good width, contributing to the overall mineralization footprint.

Positive factors

  • Strong gold grade (2.09 g/t) over a moderate width (11.9m)

Evidence · table

“2.09”

Context: 11.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-005San Luis · silverGrade: 2.32Grade Unit: g/tIntercept: 11.9 mView all details
Link to this fact

Identity

Hole ID
BOD-005
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
2.32
Grade Unit
g/t
Intercept
11.9 m
From
68.7 m
To
80.6 m
Hole Depth
160.3 m
Intercept Depth
68.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-005:68.7-80.6
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187998
Northing
8953799
Elevation
3986 m
Azimuth
55 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate width, low-grade silver intercept.

Evidence · table

“2.32”

Context: 11.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-005San Luis · goldGrade: 0.55Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
BOD-005
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
0.55
Grade Unit
g/t
Intercept
2.5 m
From
92.5 m
To
95 m
Hole Depth
160.3 m
Intercept Depth
68.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-005:92.5-95
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187998
Northing
8953799
Elevation
3986 m
Azimuth
55 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A narrow, moderate-grade gold intercept at depth.

Evidence · table

“0.55”

Context: 2.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-005San Luis · silverGrade: 15.98Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
BOD-005
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
15.98
Grade Unit
g/t
Intercept
2.5 m
From
92.5 m
To
95 m
Hole Depth
160.3 m
Intercept Depth
68.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-005:92.5-95
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187998
Northing
8953799
Elevation
3986 m
Azimuth
55 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A narrow, moderate-grade silver intercept at depth.

Positive factors

  • Moderate silver grade (15.98 g/t) over a narrow width (2.5m)

Evidence · table

“15.98”

Context: 2.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-006San Luis · goldGrade: 1.86Grade Unit: g/tIntercept: 22 mView all details
Link to this fact

Identity

Hole ID
BOD-006
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
1.86
Grade Unit
g/t
Intercept
22 m
From
2.5 m
To
24.5 m
Hole Depth
51 m
Intercept Depth
2.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-006:2.5-24.5
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187967
Northing
8953735
Elevation
3961 m
Azimuth
60 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A strong gold intercept with excellent width from near surface, supporting open-pit potential.

Positive factors

  • Strong gold grade (1.86 g/t) over a very broad width (22.0m) from near surface

Evidence · table

“1.86”

Context: 22.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-006San Luis · silverGrade: 6.91Grade Unit: g/tIntercept: 22 mView all details
Link to this fact

Identity

Hole ID
BOD-006
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
6.91
Grade Unit
g/t
Intercept
22 m
From
2.5 m
To
24.5 m
Hole Depth
51 m
Intercept Depth
2.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-006:2.5-24.5
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187967
Northing
8953735
Elevation
3961 m
Azimuth
60 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept over a very broad width, complementing the primary gold mineralization.

Positive factors

  • Moderate silver grade (6.91 g/t) over a very broad width (22.0m)

Evidence · table

“6.91”

Context: 22.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-007San Luis · goldGrade: 3.78Grade Unit: g/tIntercept: 20 mView all details
Link to this fact

Identity

Hole ID
BOD-007
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
3.78
Grade Unit
g/t
Intercept
20 m
From
4 m
To
24 m
Hole Depth
60.3 m
Intercept Depth
4 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-007:4-24
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187967
Northing
8953735
Elevation
3961 m
Azimuth
95 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A very strong gold intercept with excellent width and grade from near surface, indicating significant open-pit potential.

Positive factors

  • Strong gold grade (3.78 g/t) over a very broad width (20.0m) from near surface

Evidence · table

“3.78”

Context: 20.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-007San Luis · silverGrade: 12.31Grade Unit: g/tIntercept: 20 mView all details
Link to this fact

Identity

Hole ID
BOD-007
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
12.31
Grade Unit
g/t
Intercept
20 m
From
4 m
To
24 m
Hole Depth
60.3 m
Intercept Depth
4 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-007:4-24
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187967
Northing
8953735
Elevation
3961 m
Azimuth
95 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept over a very broad width, complementing the primary gold mineralization.

Positive factors

  • Moderate silver grade (12.31 g/t) over a very broad width (20.0m)

Evidence · table

“12.31”

Context: 20.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-008San Luis · goldGrade: 4.92Grade Unit: g/tIntercept: 23.1 mView all details
Link to this fact

Identity

Hole ID
BOD-008
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
4.92
Grade Unit
g/t
Intercept
23.1 m
From
4.7 m
To
27.7 m
Hole Depth
65 m
Intercept Depth
4.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-008:4.7-27.7
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187968
Northing
8953734
Elevation
3961 m
Azimuth
15 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A very strong gold intercept with excellent width and grade from near surface, indicating significant open-pit potential.

Positive factors

  • Strong gold grade (4.92 g/t) over a very broad width (23.1m) from near surface
  • Intercept includes a bonanza-grade sub-interval

Evidence · table

“4.92”

Context: 23.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-008San Luis · silverGrade: 16.56Grade Unit: g/tIntercept: 23.1 mView all details
Link to this fact

Identity

Hole ID
BOD-008
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
16.56
Grade Unit
g/t
Intercept
23.1 m
From
4.7 m
To
27.7 m
Hole Depth
65 m
Intercept Depth
4.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-008:4.7-27.7
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187968
Northing
8953734
Elevation
3961 m
Azimuth
15 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept over a very broad width, complementing the primary gold mineralization.

Positive factors

  • Moderate silver grade (16.56 g/t) over a very broad width (23.1m)

Evidence · table

“16.56”

Context: 23.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-008San Luis · goldGrade: 7.11Grade Unit: g/tIntercept: 13 mView all details
Link to this fact

Identity

Hole ID
BOD-008
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
7.11
Grade Unit
g/t
Intercept
13 m
From
12.3 m
To
25.3 m
Hole Depth
65 m
Intercept Depth
4.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-008:12.3-25.3
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187968
Northing
8953734
Elevation
3961 m
Azimuth
15 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: An exceptional bonanza-grade gold intercept, highlighting the high-grade potential of the system.

Positive factors

  • Bonanza gold grade (7.11 g/t) over a significant width (13.0m)
  • Indicates high-grade core within a broader mineralized zone

Evidence · table

“7.11”

Context: 13.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-008San Luis · silverGrade: 19.9Grade Unit: g/tIntercept: 13 mView all details
Link to this fact

Identity

Hole ID
BOD-008
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
19.9
Grade Unit
g/t
Intercept
13 m
From
12.3 m
To
25.3 m
Hole Depth
65 m
Intercept Depth
4.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-008:12.3-25.3
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187968
Northing
8953734
Elevation
3961 m
Azimuth
15 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept within the high-grade gold zone.

Positive factors

  • Moderate silver grade (19.90 g/t) over a significant width (13.0m)

Evidence · table

“19.90”

Context: 13.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-009San Luis · goldGrade: 1.87Grade Unit: g/tIntercept: 47.8 mView all details
Link to this fact

Identity

Hole ID
BOD-009
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
1.87
Grade Unit
g/t
Intercept
47.8 m
From
0.2 m
To
48 m
Hole Depth
60 m
Intercept Depth
0.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-009:0.2-48
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187989
Northing
8953712
Elevation
3964 m
Azimuth
110 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: An exceptionally wide and strong gold intercept starting from surface, indicating significant bulk-tonnage open-pit potential.

Positive factors

  • Strong gold grade (1.87 g/t) over an exceptionally broad width (47.8m) from surface
  • Intercept includes a bonanza-grade sub-interval

Evidence · table

“1.87”

Context: 47.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-009San Luis · silverGrade: 13.49Grade Unit: g/tIntercept: 47.8 mView all details
Link to this fact

Identity

Hole ID
BOD-009
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
13.49
Grade Unit
g/t
Intercept
47.8 m
From
0.2 m
To
48 m
Hole Depth
60 m
Intercept Depth
0.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-009:0.2-48
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187989
Northing
8953712
Elevation
3964 m
Azimuth
110 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A moderate silver intercept over an exceptionally broad width, complementing the primary gold mineralization.

Positive factors

  • Moderate silver grade (13.49 g/t) over an exceptionally broad width (47.8m)

Evidence · table

“13.49”

Context: 47.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-009San Luis · goldGrade: 12.55Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
BOD-009
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
12.55
Grade Unit
g/t
Intercept
2.1 m
From
29.7 m
To
31.8 m
Hole Depth
60 m
Intercept Depth
0.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-009:29.7-31.8
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187989
Northing
8953712
Elevation
3964 m
Azimuth
110 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: An exceptional bonanza-grade gold intercept, highlighting the high-grade potential of the system.

Positive factors

  • Bonanza gold grade (12.55 g/t) over a narrow width (2.1m)
  • Indicates high-grade core within a broader mineralized zone

Evidence · table

“12.55”

Context: 2.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

BOD-009San Luis · silverGrade: 41.2Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
BOD-009
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
41.2
Grade Unit
g/t
Intercept
2.1 m
From
29.7 m
To
31.8 m
Hole Depth
60 m
Intercept Depth
0.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
BOD-009:29.7-31.8
Mining Method
open_pit

Location

Location
Bonita Open Pit Target
Easting
187989
Northing
8953712
Elevation
3964 m
Azimuth
110 °
Dip
-40 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Compositing

Cutoff Grade
0.5
Cutoff Unit
g/t
Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: A strong silver intercept within the high-grade gold zone.

Positive factors

  • Strong silver grade (41.20 g/t) over a narrow width (2.1m)

Evidence · table

“41.20”

Context: 2.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · goldGrade: 3.7Grade Unit: g/tIntercept: 14.5 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
14.5 m
From
25.7 m
To
40.2 m
Intercept Depth
25.7 m

Classification

Sample Type
drill
Group ID
and:25.7-40.2
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 3.7 g/t gold is strong against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 53.7 g/t·m is moderate (grade alone is strong; the better of the two is used).

Positive factors

  • 3.7 g/t gold is strong on the open_pit mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.70”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · silverGrade: 17.47Grade Unit: g/tIntercept: 14.5 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
17.47
Grade Unit
g/t
Intercept
14.5 m
From
25.7 m
To
40.2 m
Intercept Depth
25.7 m

Classification

Sample Type
drill
Group ID
and:25.7-40.2
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 17.47 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 253.3 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“17.47”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · goldGrade: 5.34Grade Unit: g/tIntercept: 4.1 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
5.34
Grade Unit
g/t
Intercept
4.1 m
From
165 m
To
169.1 m
Intercept Depth
165 m

Classification

Sample Type
drill
Group ID
and:165-169.1
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 5.34 g/t gold is exceptional against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 21.9 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 5.34 g/t gold is exceptional on the open_pit mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.34”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · silverGrade: 43.22Grade Unit: g/tIntercept: 4.1 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
43.22
Grade Unit
g/t
Intercept
4.1 m
From
165 m
To
169.1 m
Intercept Depth
165 m

Classification

Sample Type
drill
Group ID
and:165-169.1
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 43.22 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 177.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“43.22”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

incl.San Luis · goldGrade: 15.15Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
incl.
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
15.15
Grade Unit
g/t
Intercept
3.3 m
From
33.7 m
To
37 m
Intercept Depth
33.7 m

Classification

Sample Type
drill
Group ID
incl.:33.7-37
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 15.15 g/t gold is exceptional against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 50.0 g/t·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 15.15 g/t gold is exceptional on the open_pit mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.15”

Context: incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

incl.San Luis · silverGrade: 14.08Grade Unit: g/tIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
incl.
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
14.08
Grade Unit
g/t
Intercept
3.3 m
From
33.7 m
To
37 m
Intercept Depth
33.7 m

Classification

Sample Type
drill
Group ID
incl.:33.7-37
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 14.08 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 46.5 g/t·m is below.

Negative factors

  • 14.08 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.08”

Context: incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · goldGrade: 0.67Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
0.67
Grade Unit
g/t
Intercept
3 m
From
193.5 m
To
196.5 m
Intercept Depth
193.5 m

Classification

Sample Type
drill
Group ID
and:193.5-196.5
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.67 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 2.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.67”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · silverGrade: 2.55Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
2.55
Grade Unit
g/t
Intercept
3 m
From
193.5 m
To
196.5 m
Intercept Depth
193.5 m

Classification

Sample Type
drill
Group ID
and:193.5-196.5
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 2.55 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.6 g/t·m is below.

Negative factors

  • 2.55 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.55”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · goldGrade: 0.55Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
0.55
Grade Unit
g/t
Intercept
2.5 m
From
92.5 m
To
95 m
Intercept Depth
92.5 m

Classification

Sample Type
drill
Group ID
and:92.5-95
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 0.55 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 1.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.55”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

andSan Luis · silverGrade: 15.98Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
and
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
15.98
Grade Unit
g/t
Intercept
2.5 m
From
92.5 m
To
95 m
Intercept Depth
92.5 m

Classification

Sample Type
drill
Group ID
and:92.5-95
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 15.98 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 40.0 g/t·m is below.

Negative factors

  • 15.98 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.98”

Context: and

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

incl.San Luis · goldGrade: 7.11Grade Unit: g/tIntercept: 13 mView all details
Link to this fact

Identity

Hole ID
incl.
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
7.11
Grade Unit
g/t
Intercept
13 m
From
12.3 m
To
25.3 m
Intercept Depth
12.3 m

Classification

Sample Type
drill
Group ID
incl.:12.3-25.3
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 7.11 g/t gold is exceptional against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 92.4 g/t·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 7.11 g/t gold is exceptional on the open_pit mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.11”

Context: incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

incl.San Luis · silverGrade: 19.9Grade Unit: g/tIntercept: 13 mView all details
Link to this fact

Identity

Hole ID
incl.
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
19.9
Grade Unit
g/t
Intercept
13 m
From
12.3 m
To
25.3 m
Intercept Depth
12.3 m

Classification

Sample Type
drill
Group ID
incl.:12.3-25.3
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 19.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 258.7 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19.90”

Context: incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

incl.San Luis · goldGrade: 12.55Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
incl.
Project
San Luis
Commodity
gold
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
12.55
Grade Unit
g/t
Intercept
2.1 m
From
29.7 m
To
31.8 m
Intercept Depth
29.7 m

Classification

Sample Type
drill
Group ID
incl.:29.7-31.8
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 12.55 g/t gold is exceptional against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 26.4 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 12.55 g/t gold is exceptional on the open_pit mining band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12.55”

Context: incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

incl.San Luis · silverGrade: 41.2Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
incl.
Project
San Luis
Commodity
silver
Region
peru
Reported Region
peru
Ticker
HSLV

Geometry

Grade
41.2
Grade Unit
g/t
Intercept
2.1 m
From
29.7 m
To
31.8 m
Intercept Depth
29.7 m

Classification

Sample Type
drill
Group ID
incl.:29.7-31.8
Mining Method
open_pit

QA/QC

Laboratory
ALS Peru S.A.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-07-29T00:00:00.000Z

Reasoning: Expanded from assay table. 41.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 86.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“41.20”

Context: incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "On behalf of Highlander Silver "Daniel Earle" President & CEO, Director Information contact Arun Lamba, Vice President C"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.