Lavras Gold Returns Broad Continuous Zones of Gold Mineralization from Ongoing Fazenda - Butiá Drilling in Brazil
Original announcement by tmx on
- Company
- Lavras Gold Corp.
- Ticker
- LGC
- Exchange
- TSX
- Region
- Brazil
- Primary commodity
- Gold
- Secondary commodities
- None reported
- Document categories
- Drill results, Resource update
- Extracted
- 2026-09-18 07:10:55 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Lavras Gold Corp. announced new assay results from its ongoing diamond drilling program at the Fazenda/Butiá Project in Brazil, part of the larger Lavras do Sul Project. The results show broad, continuous zones of gold mineralization, including high-grade intercepts such as 1.0m at 47.733 g/t Au within 21.0m at 3.117 g/t Au. The drilling program, which includes infill and step-out holes, aims to support future resource classification upgrades and expand mineralization, with QA/QC procedures detailed and reviewed by a Qualified Person. The company also provided historical NI 43-101 compliant resource estimates for the Butiá and Cerrito deposits, effective 2022.
Reasoning: Lavras Gold reports positive drill results from its Fazenda-Butiá project, confirming broad gold mineralization and high-grade zones, which will feed into future resource estimates. The program combines infill and step-out drilling, but true widths are not yet determined. Historical resource estimates are provided for context.
Positive factors
- Broad continuous gold mineralization
- High-grade intercepts within broader zones
- Drilling program includes infill and step-out components
- Detailed QA/QC procedures disclosed
- Technical information reviewed and approved by a Qualified Person
Negative factors
- True widths of intercepts are not yet known
- Resource estimates cited are historical (2022 effective dates)
Facts used in scoring: 68
Extracted facts
Stored fact records: 68. Some facts used in scoring do not have a stored record.
Drill Results (68)
25BT072Fazenda/Butiá · goldGrade: 0.408Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT072
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.408
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 5 m
- To
- 6 m
- Hole Depth
- 139.51 m
- Intercept Depth
- 5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT072:5-6
- Mining Method
- open_pit
Location
- Easting
- 218245
- Northing
- 6586550
- Elevation
- 366 m
- Azimuth
- 20 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.408”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT072Fazenda/Butiá · goldGrade: 0.201Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT072
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.201
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 39 m
- To
- 40 m
- Hole Depth
- 139.51 m
- Intercept Depth
- 5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT072:39-40
- Mining Method
- open_pit
Location
- Easting
- 218245
- Northing
- 6586550
- Elevation
- 366 m
- Azimuth
- 20 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- Narrow intercept
- True width not known
Evidence · table
“0.201”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT072Fazenda/Butiá · goldGrade: 1.1Grade Unit: g/tIntercept: 21 mView all detailsHide details
Identity
- Hole ID
- 25BT072
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.1
- Grade Unit
- g/t
- Intercept
- 21 m
- From
- 48 m
- To
- 69 m
- Hole Depth
- 139.51 m
- Intercept Depth
- 5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT072:48-69
- Mining Method
- open_pit
Location
- Easting
- 218245
- Northing
- 6586550
- Elevation
- 366 m
- Azimuth
- 20 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.
Positive factors
- Moderate grade over good width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.100”
Context: 21.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT072Fazenda/Butiá · goldGrade: 9.753Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT072
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 9.753
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 51 m
- To
- 52 m
- Hole Depth
- 139.51 m
- Intercept Depth
- 5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT072:51-52
- Mining Method
- open_pit
Location
- Easting
- 218245
- Northing
- 6586550
- Elevation
- 366 m
- Azimuth
- 20 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A high-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.
Positive factors
- High-grade intercept
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“9.753”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT072Fazenda/Butiá · goldGrade: 2.303Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT072
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.303
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 60 m
- To
- 61 m
- Hole Depth
- 139.51 m
- Intercept Depth
- 5 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT072:60-61
- Mining Method
- open_pit
Location
- Easting
- 218245
- Northing
- 6586550
- Elevation
- 366 m
- Azimuth
- 20 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.303”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT071Fazenda/Butiá · goldGrade: 1.37Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT071
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.37
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 52 m
- To
- 53 m
- Hole Depth
- 102.33 m
- Intercept Depth
- 52 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT071:52-53
- Mining Method
- open_pit
Location
- Easting
- 218244
- Northing
- 6586554
- Elevation
- 381 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.370”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT071Fazenda/Butiá · goldGrade: 1.08Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 25BT071
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.08
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 59 m
- To
- 61 m
- Hole Depth
- 102.33 m
- Intercept Depth
- 52 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT071:59-61
- Mining Method
- open_pit
Location
- Easting
- 218244
- Northing
- 6586554
- Elevation
- 381 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.080”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT070Fazenda/Butiá · goldGrade: 0.477Grade Unit: g/tIntercept: 35 mView all detailsHide details
Identity
- Hole ID
- 25BT070
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.477
- Grade Unit
- g/t
- Intercept
- 35 m
- From
- 2 m
- To
- 37 m
- Hole Depth
- 214.34 m
- Intercept Depth
- 2 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT070:2-37
- Mining Method
- open_pit
Location
- Easting
- 217985
- Northing
- 6586535
- Elevation
- 375 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.
Positive factors
- Good width at moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“0.477”
Context: 35.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT070Fazenda/Butiá · goldGrade: 1.342Grade Unit: g/tIntercept: 1.18 mView all detailsHide details
Identity
- Hole ID
- 25BT070
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.342
- Grade Unit
- g/t
- Intercept
- 1.18 m
- From
- 19 m
- To
- 20.18 m
- Hole Depth
- 214.34 m
- Intercept Depth
- 2 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT070:19-20.18
- Mining Method
- open_pit
Location
- Easting
- 217985
- Northing
- 6586535
- Elevation
- 375 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.342”
Context: 1.18
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT070Fazenda/Butiá · goldGrade: 1.206Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 25BT070
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.206
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 33 m
- To
- 37 m
- Hole Depth
- 214.34 m
- Intercept Depth
- 2 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT070:33-37
- Mining Method
- open_pit
Location
- Easting
- 217985
- Northing
- 6586535
- Elevation
- 375 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade over moderate width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.206”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT070Fazenda/Butiá · goldGrade: 0.299Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT070
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.299
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 44 m
- To
- 45 m
- Hole Depth
- 214.34 m
- Intercept Depth
- 2 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT070:44-45
- Mining Method
- open_pit
Location
- Easting
- 217985
- Northing
- 6586535
- Elevation
- 375 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.299”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT070Fazenda/Butiá · goldGrade: 0.224Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT070
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.224
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 111 m
- To
- 112 m
- Hole Depth
- 214.34 m
- Intercept Depth
- 2 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT070:111-112
- Mining Method
- open_pit
Location
- Easting
- 217985
- Northing
- 6586535
- Elevation
- 375 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- Narrow intercept
- True width not known
Evidence · table
“0.224”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT070Fazenda/Butiá · goldGrade: 0.216Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 25BT070
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.216
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 147 m
- To
- 151 m
- Hole Depth
- 214.34 m
- Intercept Depth
- 2 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT070:147-151
- Mining Method
- open_pit
Location
- Easting
- 217985
- Northing
- 6586535
- Elevation
- 375 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- True width not known
Evidence · table
“0.216”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT069Fazenda/Butiá · goldGrade: 0.328Grade Unit: g/tIntercept: 7 mView all detailsHide details
Identity
- Hole ID
- 25BT069
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.328
- Grade Unit
- g/t
- Intercept
- 7 m
- From
- 8 m
- To
- 15 m
- Hole Depth
- 142.43 m
- Intercept Depth
- 8 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT069:8-15
- Mining Method
- open_pit
Location
- Easting
- 218331
- Northing
- 6586625
- Elevation
- 372 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- True width not known
Evidence · table
“0.328”
Context: 7.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 1.014Grade Unit: g/tIntercept: 190 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.014
- Grade Unit
- g/t
- Intercept
- 190 m
- From
- 0 m
- To
- 190 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:0-190
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: An exceptional width at a moderate grade, indicating significant continuous mineralization, with disclosed QA/QC.
Positive factors
- Exceptional width at moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.014”
Context: 190.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 3.493Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 3.493
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 7 m
- To
- 8 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:7-8
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, strong-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Strong grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“3.493”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.032Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.032
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 50 m
- To
- 51 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:50-51
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.032”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.237Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.237
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 58 m
- To
- 59 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:58-59
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.237”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.837Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.837
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 99 m
- To
- 100 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:99-100
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.837”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 14.65Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 14.65
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 107 m
- To
- 108 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:107-108
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A high-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.
Positive factors
- High-grade intercept
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“14.650”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.45Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.45
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 113 m
- To
- 114 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:113-114
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.450”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.247Grade Unit: g/tIntercept: 21 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.247
- Grade Unit
- g/t
- Intercept
- 21 m
- From
- 117 m
- To
- 138 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:117-138
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A strong-grade intercept over a good width, indicating significant mineralization, with disclosed QA/QC.
Positive factors
- Strong grade over good width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“2.247”
Context: 21.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.227Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.227
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 144 m
- To
- 147 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:144-147
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a narrow width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“2.227”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.203Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.203
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 151 m
- To
- 152 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:151-152
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.203”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.058Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.058
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 154 m
- To
- 155 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:154-155
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.058”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 2.03Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.03
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 180 m
- To
- 181 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:180-181
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.030”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 3.293Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 3.293
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 183 m
- To
- 184 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:183-184
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, strong-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Strong grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“3.293”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 18.667Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 18.667
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 186 m
- To
- 187 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:186-187
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A bonanza-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.
Positive factors
- Bonanza grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“18.667”
Context: 1.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Exceptionally high-grade zone, well above the deposit-type norm.
Evidence · table
“18.667”
Context: 1.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 0.247Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.247
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 274 m
- To
- 275 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:274-275
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- Narrow intercept
- True width not known
Evidence · table
“0.247”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 0.201Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.201
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 280 m
- To
- 281 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:280-281
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- Narrow intercept
- True width not known
Evidence · table
“0.201”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 0.202Grade Unit: g/tIntercept: 19 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.202
- Grade Unit
- g/t
- Intercept
- 19 m
- From
- 287 m
- To
- 306 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:287-306
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a good width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- True width not known
Evidence · table
“0.202”
Context: 19.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 0.93Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.93
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 305 m
- To
- 306 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:305-306
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“0.930”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT068Fazenda/Butiá · goldGrade: 0.21Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 25BT068
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 316 m
- To
- 320 m
- Hole Depth
- 391.32 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT068:316-320
- Mining Method
- open_pit
Location
- Easting
- 218115
- Northing
- 6586588
- Elevation
- 367 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- True width not known
Evidence · table
“0.210”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 1.526Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.526
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 0 m
- To
- 2 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:0-2
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.526”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 0.877Grade Unit: g/tIntercept: 65 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.877
- Grade Unit
- g/t
- Intercept
- 65 m
- From
- 23 m
- To
- 88 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:23-88
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.
Positive factors
- Good width at moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“0.877”
Context: 65.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 16.05Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 16.05
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 41 m
- To
- 42 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:41-42
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A bonanza-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.
Positive factors
- Bonanza grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“16.050”
Context: 1.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Exceptionally high-grade zone, well above the deposit-type norm.
Evidence · table
“16.050”
Context: 1.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 11.287Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 11.287
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 51 m
- To
- 53 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:51-53
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A high-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.
Positive factors
- High-grade intercept
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“11.287”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 0.22Grade Unit: g/tIntercept: 13 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 13 m
- From
- 75 m
- To
- 88 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:75-88
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- True width not known
Evidence · table
“0.220”
Context: 13.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 0.321Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.321
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 99 m
- To
- 101 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:99-101
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.321”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 0.499Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.499
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 119 m
- To
- 120 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:119-120
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.499”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT067Fazenda/Butiá · goldGrade: 0.316Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT067
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.316
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 149 m
- To
- 150 m
- Hole Depth
- 186.51 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT067:149-150
- Mining Method
- open_pit
Location
- Easting
- 218277
- Northing
- 6586588
- Elevation
- 373 m
- Azimuth
- 110 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.316”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 0.512Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.512
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 22 m
- To
- 27 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:22-27
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a narrow width, but part of a broader program with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“0.512”
Context: 5.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 1.237Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.237
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 24 m
- To
- 25 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:24-25
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.237”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 0.421Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.421
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 93 m
- To
- 98 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:93-98
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- True width not known
Evidence · table
“0.421”
Context: 5.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 0.296Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.296
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 169 m
- To
- 170 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:169-170
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.296”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 0.266Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.266
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 188 m
- To
- 191 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:188-191
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a narrow width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- True width not known
Evidence · table
“0.266”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 0.743Grade Unit: g/tIntercept: 75 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.743
- Grade Unit
- g/t
- Intercept
- 75 m
- From
- 211 m
- To
- 286 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:211-286
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.
Positive factors
- Good width at moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“0.743”
Context: 75.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 5.651Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 5.651
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 238 m
- To
- 243 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:238-243
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A strong-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.
Positive factors
- Strong grade over moderate width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“5.651”
Context: 5.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 2.907Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.907
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 281 m
- To
- 282 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:281-282
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“2.907”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT066Fazenda/Butiá · goldGrade: 0.246Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT066
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.246
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 302 m
- To
- 303 m
- Hole Depth
- 401.71 m
- Intercept Depth
- 22 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT066:302-303
- Mining Method
- open_pit
Location
- Easting
- 218031
- Northing
- 6586564
- Elevation
- 371 m
- Azimuth
- 0 °
- Dip
- -90 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- Narrow intercept
- True width not known
Evidence · table
“0.246”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 2.607Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 2.607
- Grade Unit
- g/t
- Intercept
- 14 m
- From
- 63 m
- To
- 77 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:63-77
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A strong-grade intercept over a good width, indicating significant mineralization, with disclosed QA/QC.
Positive factors
- Strong grade over good width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“2.607”
Context: 14.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 8.291Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 8.291
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 63 m
- To
- 67 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:63-67
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A high-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.
Positive factors
- High-grade intercept over moderate width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“8.291”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 0.219Grade Unit: g/tIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.219
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 83 m
- To
- 98 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:83-98
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a good width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- True width not known
Evidence · table
“0.219”
Context: 15.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 0.577Grade Unit: g/tIntercept: 98 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.577
- Grade Unit
- g/t
- Intercept
- 98 m
- From
- 112 m
- To
- 210 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:112-210
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: An exceptional width at a moderate grade, indicating significant continuous mineralization, with disclosed QA/QC.
Positive factors
- Exceptional width at moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“0.577”
Context: 98.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 1.268Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.268
- Grade Unit
- g/t
- Intercept
- 8 m
- From
- 140 m
- To
- 148 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:140-148
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade over moderate width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.268”
Context: 8.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 1.093Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.093
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 158 m
- To
- 161 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:158-161
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a narrow width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.093”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 1.006Grade Unit: g/tIntercept: 14 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.006
- Grade Unit
- g/t
- Intercept
- 14 m
- From
- 170 m
- To
- 184 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:170-184
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a good width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade over good width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.006”
Context: 14.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 0.236Grade Unit: g/tIntercept: 8 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.236
- Grade Unit
- g/t
- Intercept
- 8 m
- From
- 220 m
- To
- 228 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:220-228
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- True width not known
Evidence · table
“0.236”
Context: 8.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 0.263Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.263
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 297 m
- To
- 298 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:297-298
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.263”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 0.208Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.208
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 300 m
- To
- 301 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:300-301
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Very low grade
- Narrow intercept
- True width not known
Evidence · table
“0.208”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT065Fazenda/Butiá · goldGrade: 0.251Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT065
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.251
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 305 m
- To
- 306 m
- Hole Depth
- 345.79 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT065:305-306
- Mining Method
- open_pit
Location
- Easting
- 218137
- Northing
- 6586379
- Elevation
- 395 m
- Azimuth
- 290 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
- True width not known
Evidence · table
“0.251”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 0.813Grade Unit: g/tIntercept: 59 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.813
- Grade Unit
- g/t
- Intercept
- 59 m
- From
- 0 m
- To
- 59 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:0-59
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.
Positive factors
- Good width at moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“0.813”
Context: 59.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 1.056Grade Unit: g/tIntercept: 11 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.056
- Grade Unit
- g/t
- Intercept
- 11 m
- From
- 8 m
- To
- 19 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:8-19
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade over moderate width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.056”
Context: 11.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 1.127Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.127
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 27 m
- To
- 29 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:27-29
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.127”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 1.05Grade Unit: g/tIntercept: 21 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.05
- Grade Unit
- g/t
- Intercept
- 21 m
- From
- 35 m
- To
- 56 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:35-56
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A moderate-grade intercept over a good width within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade over good width
- QA/QC disclosed
- QP signed
Negative factors
- True width not known
Evidence · table
“1.050”
Context: 21.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 0.366Grade Unit: g/tIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.366
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 69 m
- To
- 84 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:69-84
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A low-grade intercept over a good width, but part of a broader program with disclosed QA/QC.
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- True width not known
Evidence · table
“0.366”
Context: 15.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 1.071Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 1.071
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 72 m
- To
- 73 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:72-73
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.
Positive factors
- Moderate grade
- QA/QC disclosed
- QP signed
Negative factors
- Narrow intercept
- True width not known
Evidence · table
“1.071”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Evidence · text
“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Evidence · text
“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
25BT064Fazenda/Butiá · goldGrade: 0.272Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- 25BT064
- Project
- Fazenda/Butiá
- Commodity
- gold
- Region
- brazil
- Reported Region
- brazil
- Ticker
- LGC
Geometry
- Grade
- 0.272
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 121 m
- To
- 122 m
- Hole Depth
- 369.54 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- other
- Program
- mixed
- Sample Type
- drill
- Group ID
- 25BT064:121-122
- Mining Method
- open_pit
Location
- Easting
- 218113
- Northing
- 6586447
- Elevation
- 390 m
- Azimuth
- 200 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Laboratories Inc.
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- No
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-01-05T00:00:00.000Z
Positive factors
- QA/QC disclosed
- QP signed
Negative factors
- Low grade
- Narrow intercept
Evidence · table
“0.272”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.