Lavras Gold Returns Broad Continuous Zones of Gold Mineralization from Ongoing Fazenda - Butiá Drilling in Brazil

Original announcement by tmx on

Company
Lavras Gold Corp.
Ticker
LGC
Exchange
TSX
Region
Brazil
Primary commodity
Gold
Secondary commodities
None reported
Document categories
Drill results, Resource update
Extracted
2026-09-18 07:10:55 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Lavras Gold Corp. announced new assay results from its ongoing diamond drilling program at the Fazenda/Butiá Project in Brazil, part of the larger Lavras do Sul Project. The results show broad, continuous zones of gold mineralization, including high-grade intercepts such as 1.0m at 47.733 g/t Au within 21.0m at 3.117 g/t Au. The drilling program, which includes infill and step-out holes, aims to support future resource classification upgrades and expand mineralization, with QA/QC procedures detailed and reviewed by a Qualified Person. The company also provided historical NI 43-101 compliant resource estimates for the Butiá and Cerrito deposits, effective 2022.

Reasoning: Lavras Gold reports positive drill results from its Fazenda-Butiá project, confirming broad gold mineralization and high-grade zones, which will feed into future resource estimates. The program combines infill and step-out drilling, but true widths are not yet determined. Historical resource estimates are provided for context.

Positive factors

  • Broad continuous gold mineralization
  • High-grade intercepts within broader zones
  • Drilling program includes infill and step-out components
  • Detailed QA/QC procedures disclosed
  • Technical information reviewed and approved by a Qualified Person

Negative factors

  • True widths of intercepts are not yet known
  • Resource estimates cited are historical (2022 effective dates)

Facts used in scoring: 68

Extracted facts

Stored fact records: 68. Some facts used in scoring do not have a stored record.

Drill Results (68)

25BT072Fazenda/Butiá · goldGrade: 0.408Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT072
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.408
Grade Unit
g/t
Intercept
1 m
From
5 m
To
6 m
Hole Depth
139.51 m
Intercept Depth
5 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT072:5-6
Mining Method
open_pit

Location

Easting
218245
Northing
6586550
Elevation
366 m
Azimuth
20 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.408”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT072Fazenda/Butiá · goldGrade: 0.201Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT072
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.201
Grade Unit
g/t
Intercept
1 m
From
39 m
To
40 m
Hole Depth
139.51 m
Intercept Depth
5 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT072:39-40
Mining Method
open_pit

Location

Easting
218245
Northing
6586550
Elevation
366 m
Azimuth
20 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.201”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT072Fazenda/Butiá · goldGrade: 1.1Grade Unit: g/tIntercept: 21 mView all details
Link to this fact

Identity

Hole ID
25BT072
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
21 m
From
48 m
To
69 m
Hole Depth
139.51 m
Intercept Depth
5 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT072:48-69
Mining Method
open_pit

Location

Easting
218245
Northing
6586550
Elevation
366 m
Azimuth
20 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.

Positive factors

  • Moderate grade over good width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.100”

Context: 21.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT072Fazenda/Butiá · goldGrade: 9.753Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT072
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
9.753
Grade Unit
g/t
Intercept
1 m
From
51 m
To
52 m
Hole Depth
139.51 m
Intercept Depth
5 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT072:51-52
Mining Method
open_pit

Location

Easting
218245
Northing
6586550
Elevation
366 m
Azimuth
20 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A high-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.

Positive factors

  • High-grade intercept
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“9.753”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT072Fazenda/Butiá · goldGrade: 2.303Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT072
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.303
Grade Unit
g/t
Intercept
1 m
From
60 m
To
61 m
Hole Depth
139.51 m
Intercept Depth
5 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT072:60-61
Mining Method
open_pit

Location

Easting
218245
Northing
6586550
Elevation
366 m
Azimuth
20 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.303”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT071Fazenda/Butiá · goldGrade: 1.37Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT071
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.37
Grade Unit
g/t
Intercept
1 m
From
52 m
To
53 m
Hole Depth
102.33 m
Intercept Depth
52 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT071:52-53
Mining Method
open_pit

Location

Easting
218244
Northing
6586554
Elevation
381 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.370”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT071Fazenda/Butiá · goldGrade: 1.08Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
25BT071
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.08
Grade Unit
g/t
Intercept
2 m
From
59 m
To
61 m
Hole Depth
102.33 m
Intercept Depth
52 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT071:59-61
Mining Method
open_pit

Location

Easting
218244
Northing
6586554
Elevation
381 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.080”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT070Fazenda/Butiá · goldGrade: 0.477Grade Unit: g/tIntercept: 35 mView all details
Link to this fact

Identity

Hole ID
25BT070
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.477
Grade Unit
g/t
Intercept
35 m
From
2 m
To
37 m
Hole Depth
214.34 m
Intercept Depth
2 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT070:2-37
Mining Method
open_pit

Location

Easting
217985
Northing
6586535
Elevation
375 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.

Positive factors

  • Good width at moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“0.477”

Context: 35.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT070Fazenda/Butiá · goldGrade: 1.342Grade Unit: g/tIntercept: 1.18 mView all details
Link to this fact

Identity

Hole ID
25BT070
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.342
Grade Unit
g/t
Intercept
1.18 m
From
19 m
To
20.18 m
Hole Depth
214.34 m
Intercept Depth
2 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT070:19-20.18
Mining Method
open_pit

Location

Easting
217985
Northing
6586535
Elevation
375 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.342”

Context: 1.18

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT070Fazenda/Butiá · goldGrade: 1.206Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
25BT070
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.206
Grade Unit
g/t
Intercept
4 m
From
33 m
To
37 m
Hole Depth
214.34 m
Intercept Depth
2 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT070:33-37
Mining Method
open_pit

Location

Easting
217985
Northing
6586535
Elevation
375 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade over moderate width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.206”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT070Fazenda/Butiá · goldGrade: 0.299Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT070
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.299
Grade Unit
g/t
Intercept
1 m
From
44 m
To
45 m
Hole Depth
214.34 m
Intercept Depth
2 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT070:44-45
Mining Method
open_pit

Location

Easting
217985
Northing
6586535
Elevation
375 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.299”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT070Fazenda/Butiá · goldGrade: 0.224Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT070
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.224
Grade Unit
g/t
Intercept
1 m
From
111 m
To
112 m
Hole Depth
214.34 m
Intercept Depth
2 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT070:111-112
Mining Method
open_pit

Location

Easting
217985
Northing
6586535
Elevation
375 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.224”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT070Fazenda/Butiá · goldGrade: 0.216Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
25BT070
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.216
Grade Unit
g/t
Intercept
4 m
From
147 m
To
151 m
Hole Depth
214.34 m
Intercept Depth
2 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT070:147-151
Mining Method
open_pit

Location

Easting
217985
Northing
6586535
Elevation
375 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • True width not known

Evidence · table

“0.216”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT069Fazenda/Butiá · goldGrade: 0.328Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
25BT069
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.328
Grade Unit
g/t
Intercept
7 m
From
8 m
To
15 m
Hole Depth
142.43 m
Intercept Depth
8 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT069:8-15
Mining Method
open_pit

Location

Easting
218331
Northing
6586625
Elevation
372 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • True width not known

Evidence · table

“0.328”

Context: 7.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 1.014Grade Unit: g/tIntercept: 190 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.014
Grade Unit
g/t
Intercept
190 m
From
0 m
To
190 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:0-190
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: An exceptional width at a moderate grade, indicating significant continuous mineralization, with disclosed QA/QC.

Positive factors

  • Exceptional width at moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.014”

Context: 190.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 3.493Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
3.493
Grade Unit
g/t
Intercept
1 m
From
7 m
To
8 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:7-8
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, strong-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Strong grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“3.493”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.032Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.032
Grade Unit
g/t
Intercept
1 m
From
50 m
To
51 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:50-51
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.032”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.237Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.237
Grade Unit
g/t
Intercept
1 m
From
58 m
To
59 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:58-59
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.237”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.837Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.837
Grade Unit
g/t
Intercept
1 m
From
99 m
To
100 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:99-100
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.837”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 14.65Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
14.65
Grade Unit
g/t
Intercept
1 m
From
107 m
To
108 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:107-108
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A high-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.

Positive factors

  • High-grade intercept
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“14.650”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.45Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.45
Grade Unit
g/t
Intercept
1 m
From
113 m
To
114 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:113-114
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.450”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.247Grade Unit: g/tIntercept: 21 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.247
Grade Unit
g/t
Intercept
21 m
From
117 m
To
138 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:117-138
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A strong-grade intercept over a good width, indicating significant mineralization, with disclosed QA/QC.

Positive factors

  • Strong grade over good width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“2.247”

Context: 21.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.227Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.227
Grade Unit
g/t
Intercept
3 m
From
144 m
To
147 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:144-147
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a narrow width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“2.227”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.203Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.203
Grade Unit
g/t
Intercept
1 m
From
151 m
To
152 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:151-152
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.203”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.058Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.058
Grade Unit
g/t
Intercept
1 m
From
154 m
To
155 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:154-155
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.058”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 2.03Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.03
Grade Unit
g/t
Intercept
1 m
From
180 m
To
181 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:180-181
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.030”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 3.293Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
3.293
Grade Unit
g/t
Intercept
1 m
From
183 m
To
184 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:183-184
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, strong-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Strong grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“3.293”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 18.667Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
18.667
Grade Unit
g/t
Intercept
1 m
From
186 m
To
187 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:186-187
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A bonanza-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.

Positive factors

  • Bonanza grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“18.667”

Context: 1.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Exceptionally high-grade zone, well above the deposit-type norm.

Evidence · table

“18.667”

Context: 1.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 0.247Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.247
Grade Unit
g/t
Intercept
1 m
From
274 m
To
275 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:274-275
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.247”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 0.201Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.201
Grade Unit
g/t
Intercept
1 m
From
280 m
To
281 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:280-281
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.201”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 0.202Grade Unit: g/tIntercept: 19 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.202
Grade Unit
g/t
Intercept
19 m
From
287 m
To
306 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:287-306
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a good width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • True width not known

Evidence · table

“0.202”

Context: 19.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 0.93Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.93
Grade Unit
g/t
Intercept
1 m
From
305 m
To
306 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:305-306
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“0.930”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT068Fazenda/Butiá · goldGrade: 0.21Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
25BT068
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.21
Grade Unit
g/t
Intercept
4 m
From
316 m
To
320 m
Hole Depth
391.32 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT068:316-320
Mining Method
open_pit

Location

Easting
218115
Northing
6586588
Elevation
367 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • True width not known

Evidence · table

“0.210”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 1.526Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.526
Grade Unit
g/t
Intercept
2 m
From
0 m
To
2 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:0-2
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept, contributing to the overall mineralization, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.526”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 0.877Grade Unit: g/tIntercept: 65 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.877
Grade Unit
g/t
Intercept
65 m
From
23 m
To
88 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:23-88
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.

Positive factors

  • Good width at moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“0.877”

Context: 65.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 16.05Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
16.05
Grade Unit
g/t
Intercept
1 m
From
41 m
To
42 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:41-42
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A bonanza-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.

Positive factors

  • Bonanza grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“16.050”

Context: 1.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Exceptionally high-grade zone, well above the deposit-type norm.

Evidence · table

“16.050”

Context: 1.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 11.287Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
11.287
Grade Unit
g/t
Intercept
2 m
From
51 m
To
53 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:51-53
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A high-grade intercept, though narrow, indicating high-grade shoots within broader mineralization, with disclosed QA/QC.

Positive factors

  • High-grade intercept
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“11.287”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 0.22Grade Unit: g/tIntercept: 13 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.22
Grade Unit
g/t
Intercept
13 m
From
75 m
To
88 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:75-88
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • True width not known

Evidence · table

“0.220”

Context: 13.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 0.321Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.321
Grade Unit
g/t
Intercept
2 m
From
99 m
To
101 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:99-101
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.321”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 0.499Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.499
Grade Unit
g/t
Intercept
1 m
From
119 m
To
120 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:119-120
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.499”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT067Fazenda/Butiá · goldGrade: 0.316Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT067
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.316
Grade Unit
g/t
Intercept
1 m
From
149 m
To
150 m
Hole Depth
186.51 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT067:149-150
Mining Method
open_pit

Location

Easting
218277
Northing
6586588
Elevation
373 m
Azimuth
110 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.316”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 0.512Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.512
Grade Unit
g/t
Intercept
5 m
From
22 m
To
27 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:22-27
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a narrow width, but part of a broader program with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“0.512”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 1.237Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.237
Grade Unit
g/t
Intercept
1 m
From
24 m
To
25 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:24-25
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.237”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 0.421Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.421
Grade Unit
g/t
Intercept
5 m
From
93 m
To
98 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:93-98
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • True width not known

Evidence · table

“0.421”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 0.296Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.296
Grade Unit
g/t
Intercept
1 m
From
169 m
To
170 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:169-170
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.296”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 0.266Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.266
Grade Unit
g/t
Intercept
3 m
From
188 m
To
191 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:188-191
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a narrow width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • True width not known

Evidence · table

“0.266”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 0.743Grade Unit: g/tIntercept: 75 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.743
Grade Unit
g/t
Intercept
75 m
From
211 m
To
286 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:211-286
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.

Positive factors

  • Good width at moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“0.743”

Context: 75.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 5.651Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
5.651
Grade Unit
g/t
Intercept
5 m
From
238 m
To
243 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:238-243
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A strong-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.

Positive factors

  • Strong grade over moderate width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“5.651”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 2.907Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.907
Grade Unit
g/t
Intercept
1 m
From
281 m
To
282 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:281-282
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“2.907”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT066Fazenda/Butiá · goldGrade: 0.246Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT066
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.246
Grade Unit
g/t
Intercept
1 m
From
302 m
To
303 m
Hole Depth
401.71 m
Intercept Depth
22 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT066:302-303
Mining Method
open_pit

Location

Easting
218031
Northing
6586564
Elevation
371 m
Azimuth
0 °
Dip
-90 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.246”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 2.607Grade Unit: g/tIntercept: 14 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
2.607
Grade Unit
g/t
Intercept
14 m
From
63 m
To
77 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:63-77
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A strong-grade intercept over a good width, indicating significant mineralization, with disclosed QA/QC.

Positive factors

  • Strong grade over good width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“2.607”

Context: 14.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 8.291Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
8.291
Grade Unit
g/t
Intercept
4 m
From
63 m
To
67 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:63-67
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A high-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.

Positive factors

  • High-grade intercept over moderate width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“8.291”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 0.219Grade Unit: g/tIntercept: 15 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.219
Grade Unit
g/t
Intercept
15 m
From
83 m
To
98 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:83-98
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a good width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • True width not known

Evidence · table

“0.219”

Context: 15.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 0.577Grade Unit: g/tIntercept: 98 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.577
Grade Unit
g/t
Intercept
98 m
From
112 m
To
210 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:112-210
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: An exceptional width at a moderate grade, indicating significant continuous mineralization, with disclosed QA/QC.

Positive factors

  • Exceptional width at moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“0.577”

Context: 98.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 1.268Grade Unit: g/tIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.268
Grade Unit
g/t
Intercept
8 m
From
140 m
To
148 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:140-148
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade over moderate width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.268”

Context: 8.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 1.093Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.093
Grade Unit
g/t
Intercept
3 m
From
158 m
To
161 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:158-161
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a narrow width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.093”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 1.006Grade Unit: g/tIntercept: 14 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.006
Grade Unit
g/t
Intercept
14 m
From
170 m
To
184 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:170-184
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a good width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade over good width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.006”

Context: 14.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 0.236Grade Unit: g/tIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.236
Grade Unit
g/t
Intercept
8 m
From
220 m
To
228 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:220-228
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a moderate width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • True width not known

Evidence · table

“0.236”

Context: 8.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 0.263Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.263
Grade Unit
g/t
Intercept
1 m
From
297 m
To
298 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:297-298
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.263”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 0.208Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.208
Grade Unit
g/t
Intercept
1 m
From
300 m
To
301 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:300-301
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A very narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Very low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.208”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT065Fazenda/Butiá · goldGrade: 0.251Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT065
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.251
Grade Unit
g/t
Intercept
1 m
From
305 m
To
306 m
Hole Depth
345.79 m
Intercept Depth
63 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT065:305-306
Mining Method
open_pit

Location

Easting
218137
Northing
6586379
Elevation
395 m
Azimuth
290 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, low-grade intercept, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept
  • True width not known

Evidence · table

“0.251”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 0.813Grade Unit: g/tIntercept: 59 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.813
Grade Unit
g/t
Intercept
59 m
From
0 m
To
59 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:0-59
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A good width at a moderate grade, contributing to the overall resource base, with disclosed QA/QC.

Positive factors

  • Good width at moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“0.813”

Context: 59.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 1.056Grade Unit: g/tIntercept: 11 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.056
Grade Unit
g/t
Intercept
11 m
From
8 m
To
19 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:8-19
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a moderate width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade over moderate width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.056”

Context: 11.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 1.127Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.127
Grade Unit
g/t
Intercept
2 m
From
27 m
To
29 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:27-29
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.127”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 1.05Grade Unit: g/tIntercept: 21 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.05
Grade Unit
g/t
Intercept
21 m
From
35 m
To
56 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:35-56
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A moderate-grade intercept over a good width within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade over good width
  • QA/QC disclosed
  • QP signed

Negative factors

  • True width not known

Evidence · table

“1.050”

Context: 21.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 0.366Grade Unit: g/tIntercept: 15 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.366
Grade Unit
g/t
Intercept
15 m
From
69 m
To
84 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:69-84
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A low-grade intercept over a good width, but part of a broader program with disclosed QA/QC.

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • True width not known

Evidence · table

“0.366”

Context: 15.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 1.071Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
1.071
Grade Unit
g/t
Intercept
1 m
From
72 m
To
73 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:72-73
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Reasoning: A narrow, moderate-grade intercept within a broader zone, with disclosed QA/QC.

Positive factors

  • Moderate grade
  • QA/QC disclosed
  • QP signed

Negative factors

  • Narrow intercept
  • True width not known

Evidence · table

“1.071”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Evidence · text

“Note: All intervals are reported as down-hole lengths; true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Evidence · text

“Quality Assurance & Quality Control: Sample handling, preparation, and analysis are monitored through the implementation of formal chain-of-custody procedures and quality assurance/quality control programs designed to follow industry best practices.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

25BT064Fazenda/Butiá · goldGrade: 0.272Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
25BT064
Project
Fazenda/Butiá
Commodity
gold
Region
brazil
Reported Region
brazil
Ticker
LGC

Geometry

Grade
0.272
Grade Unit
g/t
Intercept
1 m
From
121 m
To
122 m
Hole Depth
369.54 m
Intercept Depth
0 m

Classification

Deposit Type
other
Program
mixed
Sample Type
drill
Group ID
25BT064:121-122
Mining Method
open_pit

Location

Easting
218113
Northing
6586447
Elevation
390 m
Azimuth
200 °
Dip
-60 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Laboratories Inc.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
No

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-05T00:00:00.000Z

Positive factors

  • QA/QC disclosed
  • QP signed

Negative factors

  • Low grade
  • Narrow intercept

Evidence · table

“0.272”

Context: 1.00

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.