Lion Delivers High-Grade Copper Intercepts and Positive Metallurgy on Low-Low Grade Mineralization
Original announcement by tmx on
- Company
- Power Metallic Mines Inc.
- Ticker
- PNPN
- Exchange
- TSX
- Region
- Canada
- Primary commodity
- Copper
- Secondary commodities
- Gold, Silver, Palladium, Platinum, Nickel
- Document categories
- Drill results, Metallurgy
- Extracted
- 2026-09-13 19:11:43 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Power Metallic Mines Inc. announced high-grade copper intercepts from its winter 2026 drill program at the Lion Zone, including 4.07 metres grading 8.73% CuEqRec and 10.30 metres grading 4.04% CuEqRec. Concurrently, locked-cycle metallurgical testing on low-grade disseminated mineralization returned encouraging recovery results, confirming the viability of processing lower-grade material and enhancing the project's economic potential for the upcoming NI-43-101 Mineral Resource Estimate.
Reasoning: Power Metallic Mines Inc. reported new high-grade copper intercepts from its infill drill program at the Lion Zone, which will contribute to an upcoming MRE. Additionally, positive locked-cycle metallurgical test results for low-grade disseminated mineralization confirm strong recovery potential, indicating enhanced project economics and the ability to include significant volumes of lower-grade material in the resource estimate.
Positive factors
- High-grade copper intercepts reported
- Positive locked-cycle metallurgical test results for low-grade material
- Metallurgy confirms strong recovery potential, enhancing project economics
- Upcoming NI-43-101 MRE and PEA planned
- QA/QC procedures disclosed with certified laboratory and QP sign-off
- True width estimated for most drill intercepts
Negative factors
- Metal equivalent assumptions are based on very old (2006) data
- True width is unknown for one significant intercept (PML-26-072)
- No direct RAG comparison possible as prior results are for different projects and commodities
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 140
Classification and evidence
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: the document describes a flotation route ("flotation")
Single Domain Onlynegative
Testing limited to one composite or domain — representativeness not established.
Why it applies: only one composite was tested
Extracted facts
Stored fact records: 140. Some facts used in scoring do not have a stored record.
Drill Results (135)
PML-26-067Lion Zone · copperGrade: 5.88Grade Unit: %Intercept: 4.07 mView all detailsHide details
Identity
- Hole ID
- PML-26-067
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 5.88
- Grade Unit
- %
- Intercept
- 4.07 m
- True Width
- 3.46 m
- From
- 53.93 m
- To
- 58 m
- Intercept Depth
- 50 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-067:53.93-58
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.73
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows exceptional copper grade, contributing significantly to the high copper equivalent, with true width estimated and robust QA/QC.
Positive factors
- Bonanza Intercept (5.88% Cu is exceptional for VMS deposit)
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
- High metal equivalent grade
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“5.88”
Context: 4.07
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: 5.88% Cu is exceptional for a VMS deposit (rubric: >=2.5% exceptional).
Evidence · table
“5.88”
Context: 4.07
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-070Lion Zone · copperGrade: 0.5Grade Unit: %Intercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PML-26-070
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.5
- Grade Unit
- %
- Intercept
- 1.61 m
- True Width
- 1.37 m
- From
- 57 m
- To
- 58.61 m
- Intercept Depth
- 57 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-070:57-58.61
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a weak copper grade for a VMS deposit, but contributes to the overall resource with estimated true width and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Weak copper grade for VMS deposit
- Metal equivalent assumptions are old
Evidence · table
“0.50”
Context: 1.61
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-072Lion Zone · copperGrade: 0.34Grade Unit: %Intercept: 64.67 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.34
- Grade Unit
- %
- Intercept
- 64.67 m
- From
- 15.33 m
- To
- 80 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-072:15.33-80
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.6
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This broad intercept shows weak copper grade for a VMS deposit, and its true width is unknown, but it contributes to the overall resource with robust QA/QC.
Positive factors
- Significant intercept length
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Weak copper grade for VMS deposit
- Apparent Width Only (true width unknown)
- Metal equivalent assumptions are old
Evidence · table
“0.34”
Context: 64.67
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Hole PML-26-072 was an 'off-angle' hole, and its true width is explicitly stated as unknown.
Evidence · text
“True width is unknown.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-072Lion Zone · copperGrade: 1.49Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.49
- Grade Unit
- %
- Intercept
- 2 m
- From
- 16 m
- To
- 18 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-072:16-18
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.36
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing to the overall resource, but its true width is unknown.
Positive factors
- Moderate copper grade for VMS deposit
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Apparent Width Only (true width unknown)
- Metal equivalent assumptions are old
Evidence · table
“1.49”
Context: 2.00
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Hole PML-26-072 was an 'off-angle' hole, and its true width is explicitly stated as unknown.
Evidence · text
“True width is unknown.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-072Lion Zone · copperGrade: 1.72Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.72
- Grade Unit
- %
- Intercept
- 2 m
- From
- 39.5 m
- To
- 41.5 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-072:39.5-41.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.99
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a strong copper grade for a VMS deposit, contributing positively to the overall resource, but its true width is unknown.
Positive factors
- Strong copper grade for VMS deposit
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Apparent Width Only (true width unknown)
- Metal equivalent assumptions are old
Evidence · table
“1.72”
Context: 2.00
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Hole PML-26-072 was an 'off-angle' hole, and its true width is explicitly stated as unknown.
Evidence · text
“True width is unknown.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-072Lion Zone · copperGrade: 0.55Grade Unit: %Intercept: 5.27 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.55
- Grade Unit
- %
- Intercept
- 5.27 m
- From
- 56 m
- To
- 61.27 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-072:56-61.27
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.19
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing to the overall resource, but its true width is unknown.
Positive factors
- Moderate copper grade for VMS deposit
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Apparent Width Only (true width unknown)
- Metal equivalent assumptions are old
Evidence · table
“0.55”
Context: 5.27
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Apparent Width OnlyRejected · negative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Reason: Hole PML-26-072 was an 'off-angle' hole, and its true width is explicitly stated as unknown.
Evidence · text
“True width is unknown.”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-077Lion Zone · copperGrade: 0.32Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 20 m
- True Width
- 17 m
- From
- 90 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-077:90-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.65
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This broad intercept shows weak copper grade for a VMS deposit, but contributes to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Significant intercept length
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Weak copper grade for VMS deposit
- Metal equivalent assumptions are old
Evidence · table
“0.32”
Context: 20.00
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-077Lion Zone · copperGrade: 1.09Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.09
- Grade Unit
- %
- Intercept
- 2 m
- True Width
- 1.7 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-077:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.4
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing positively to the overall resource, with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“1.09”
Context: 2.00
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-091Lion Zone · copperGrade: 0.49Grade Unit: %Intercept: 12.35 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.49
- Grade Unit
- %
- Intercept
- 12.35 m
- True Width
- 10.5 m
- From
- 179 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-091:179-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.67
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit, contributing to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.49”
Context: 12.35
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-091Lion Zone · copperGrade: 0.78Grade Unit: %Intercept: 4.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.78
- Grade Unit
- %
- Intercept
- 4.5 m
- True Width
- 3.82 m
- From
- 186.85 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-091:186.85-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.82
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing positively to the overall resource, with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.78”
Context: 4.50
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-097Lion Zone · copperGrade: 0.55Grade Unit: %Intercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.55
- Grade Unit
- %
- Intercept
- 10.3 m
- True Width
- 8.76 m
- From
- 91.5 m
- To
- 101.8 m
- Intercept Depth
- 75 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-097:91.5-101.8
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.04
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit over a significant length, contributing positively to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- Significant intercept length
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
- High metal equivalent grade
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.55”
Context: 10.30
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-097Lion Zone · copperGrade: 0.87Grade Unit: %Intercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.87
- Grade Unit
- %
- Intercept
- 2.5 m
- True Width
- 2.12 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 75 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-097:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.33
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit, contributing to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.87”
Context: 2.50
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-099Lion Zone · copperGrade: 0.3Grade Unit: %Intercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.3
- Grade Unit
- %
- Intercept
- 5.6 m
- True Width
- 4.76 m
- From
- 34 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-099:34-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.42
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a weak copper grade for a VMS deposit, but contributes to the overall resource with estimated true width and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Weak copper grade for VMS deposit
- Metal equivalent assumptions are old
Evidence · table
“0.30”
Context: 5.60
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-099Lion Zone · copperGrade: 0.39Grade Unit: %Intercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.39
- Grade Unit
- %
- Intercept
- 2.6 m
- True Width
- 2.21 m
- From
- 37 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-099:37-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.56
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a weak copper grade for a VMS deposit, but contributes to the overall resource with estimated true width and robust QA/QC.
Positive factors
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Weak copper grade for VMS deposit
- Metal equivalent assumptions are old
Evidence · table
“0.39”
Context: 2.60
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-099Lion Zone · copperGrade: 0.45Grade Unit: %Intercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 2.2 m
- True Width
- 1.87 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-099:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.46
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.45”
Context: 2.20
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-102Lion Zone · copperGrade: 1.03Grade Unit: %Intercept: 10.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.03
- Grade Unit
- %
- Intercept
- 10.45 m
- True Width
- 8.88 m
- From
- 173.9 m
- To
- 184.35 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-102:173.9-184.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.24
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit over a significant length, contributing positively to the overall resource, with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- Significant intercept length
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“1.03”
Context: 10.45
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-102Lion Zone · copperGrade: 2.71Grade Unit: %Intercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 2.71
- Grade Unit
- %
- Intercept
- 2.8 m
- True Width
- 2.38 m
- From
- 174.6 m
- To
- 177.4 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-102:174.6-177.4
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.67
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows exceptional copper grade, contributing significantly to the high copper equivalent, with estimated true width and robust QA/QC.
Positive factors
- Bonanza Intercept (2.71% Cu is exceptional for VMS deposit)
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
- High metal equivalent grade
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“2.71”
Context: 2.80
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
Bonanza InterceptRejected · positive
Exceptionally high-grade zone, well above the deposit-type norm.
Reason: 2.71% Cu is exceptional for a VMS deposit (rubric: >=2.5% exceptional).
Evidence · table
“2.71”
Context: 2.80
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-102Lion Zone · copperGrade: 0.6Grade Unit: %Intercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 3.8 m
- True Width
- 3.23 m
- From
- 178.7 m
- To
- 182.5 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-102:178.7-182.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.76
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing to the overall resource, with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.60”
Context: 3.80
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-102Lion Zone · copperGrade: 0.54Grade Unit: %Intercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.54
- Grade Unit
- %
- Intercept
- 4.1 m
- True Width
- 3.48 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-102:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.82
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing to the overall resource, with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.54”
Context: 4.10
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-103Lion Zone · copperGrade: 0.98Grade Unit: %Intercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-103
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.98
- Grade Unit
- %
- Intercept
- 1.45 m
- True Width
- 1.23 m
- From
- 93 m
- To
- 94.45 m
- Intercept Depth
- 93 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-103:93-94.45
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.31
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade for a VMS deposit, contributing to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.98”
Context: 1.45
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-109Lion Zone · copperGrade: 0.68Grade Unit: %Intercept: 22.71 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 22.71 m
- True Width
- 19.3 m
- From
- 123 m
- To
- 145.71 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-109:123-145.71
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.45
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This broad intercept shows a moderate copper grade for a VMS deposit, contributing to the overall resource with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- Significant intercept length
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.68”
Context: 22.71
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-109Lion Zone · copperGrade: 0.96Grade Unit: %Intercept: 8.95 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.96
- Grade Unit
- %
- Intercept
- 8.95 m
- True Width
- 7.61 m
- From
- 129.05 m
- To
- 138 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Program
- resource
- Sample Type
- drill
- Group ID
- PML-26-109:129.05-138
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.28
- Metal Eq. Unit
- % CuEqRec
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This sub-interval shows a moderate copper grade for a VMS deposit, contributing positively to the overall resource, with estimated true width and robust QA/QC.
Positive factors
- Moderate copper grade for VMS deposit
- True Width Disclosed
- QA/QC Disclosed
- Certified Lab
- QP Signed
Negative factors
- Metal equivalent assumptions are old
Evidence · table
“0.96”
Context: 8.95
Tags used in scoring
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Rejected tags
Rejected tags — excluded from scoring because their label or evidence could not be verified.
True Width DisclosedRejected · positive
Actual thickness perpendicular to structure is stated, not just downhole length.
Reason: True width is estimated as 85% of downhole length.
Evidence · text
“true width based on model projections is estimated as 85% of downhole length”
QA/QC DisclosedRejected · positive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Reason: The release details QA/QC procedures including standards, duplicates, and blanks, with analysis by an ISO certified lab and QP sign-off.
Evidence · text
“GeoVector's QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed, and no material errors were observed. All samples were submitted to and analyzed at Activation Laboratories Ltd ("Actlabs"), a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories.”
Metal Equivalent OpaqueRejected · negative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Reason: The metal equivalent calculation relies on metal prices and recoveries from a press release dated January 21, 2006, which is very old.
Evidence · text
“see press release Jan 21, 2006”
Infill DrillingRejected · neutral
Confirmatory drilling to raise resource confidence, not new discovery.
Reason: The drill holes were part of an infill program designed to increase confidence in mineralized zones for an upcoming MRE.
Evidence · text
“The infill drill holes in this release were drilled to increase the confidence in the mineralized zones that are within the range of a potential future open pit.”
PML-26-067Lion Zone · goldGrade: 0.35Grade Unit: g/tIntercept: 4.07 mView all detailsHide details
Identity
- Hole ID
- PML-26-067
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.35
- Grade Unit
- g/t
- Intercept
- 4.07 m
- From
- 53.93 m
- To
- 58 m
- Intercept Depth
- 53.93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-067:53.93-58
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.35 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 1.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.35”
Context: PML-26-067
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-067Lion Zone · silverGrade: 7.88Grade Unit: g/tIntercept: 4.07 mView all detailsHide details
Identity
- Hole ID
- PML-26-067
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 7.88
- Grade Unit
- g/t
- Intercept
- 4.07 m
- From
- 53.93 m
- To
- 58 m
- Intercept Depth
- 53.93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-067:53.93-58
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 7.88 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 32.1 g/t·m is below.
Negative factors
- 7.88 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.88”
Context: PML-26-067
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-067Lion Zone · palladiumGrade: 5.03Grade Unit: g/tIntercept: 4.07 mView all detailsHide details
Identity
- Hole ID
- PML-26-067
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 5.03
- Grade Unit
- g/t
- Intercept
- 4.07 m
- From
- 53.93 m
- To
- 58 m
- Intercept Depth
- 53.93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-067:53.93-58
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 5.03 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“5.03”
Context: PML-26-067
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-067Lion Zone · platinumGrade: 0.04Grade Unit: g/tIntercept: 4.07 mView all detailsHide details
Identity
- Hole ID
- PML-26-067
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 4.07 m
- From
- 53.93 m
- To
- 58 m
- Intercept Depth
- 53.93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-067:53.93-58
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.04 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.04”
Context: PML-26-067
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-067Lion Zone · nickelGrade: 0.25Grade Unit: %Intercept: 4.07 mView all detailsHide details
Identity
- Hole ID
- PML-26-067
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.25
- Grade Unit
- %
- Intercept
- 4.07 m
- From
- 53.93 m
- To
- 58 m
- Intercept Depth
- 53.93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-067:53.93-58
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.25 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.25 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.25”
Context: PML-26-067
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-070Lion Zone · goldGrade: 0.04Grade Unit: g/tIntercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PML-26-070
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 1.61 m
- From
- 57 m
- To
- 58.61 m
- Intercept Depth
- 57 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-070:57-58.61
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.04 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: PML-26-070
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-070Lion Zone · silverGrade: 7.02Grade Unit: g/tIntercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PML-26-070
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 7.02
- Grade Unit
- g/t
- Intercept
- 1.61 m
- From
- 57 m
- To
- 58.61 m
- Intercept Depth
- 57 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-070:57-58.61
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 7.02 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.3 g/t·m is below.
Negative factors
- 7.02 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.02”
Context: PML-26-070
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-070Lion Zone · palladiumGrade: 0.45Grade Unit: g/tIntercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PML-26-070
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 1.61 m
- From
- 57 m
- To
- 58.61 m
- Intercept Depth
- 57 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-070:57-58.61
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.45 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.45”
Context: PML-26-070
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-070Lion Zone · platinumGrade: 0.06Grade Unit: g/tIntercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PML-26-070
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 1.61 m
- From
- 57 m
- To
- 58.61 m
- Intercept Depth
- 57 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-070:57-58.61
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.06 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.06”
Context: PML-26-070
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-070Lion Zone · nickelGrade: 0.1Grade Unit: %Intercept: 1.61 mView all detailsHide details
Identity
- Hole ID
- PML-26-070
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 1.61 m
- From
- 57 m
- To
- 58.61 m
- Intercept Depth
- 57 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-070:57-58.61
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.1 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: PML-26-070
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · goldGrade: 0.21Grade Unit: g/tIntercept: 64.67 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 64.67 m
- From
- 15.33 m
- To
- 80 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:15.33-80
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 13.6 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: PML-26-072
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · silverGrade: 6.59Grade Unit: g/tIntercept: 64.67 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 6.59
- Grade Unit
- g/t
- Intercept
- 64.67 m
- From
- 15.33 m
- To
- 80 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:15.33-80
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 6.59 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 426.2 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.59”
Context: PML-26-072
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · palladiumGrade: 0.09Grade Unit: g/tIntercept: 64.67 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 64.67 m
- From
- 15.33 m
- To
- 80 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:15.33-80
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.09 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.09”
Context: PML-26-072
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · platinumGrade: 0Grade Unit: g/tIntercept: 64.67 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 64.67 m
- From
- 15.33 m
- To
- 80 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:15.33-80
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.00”
Context: PML-26-072
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · nickelGrade: 0.01Grade Unit: %Intercept: 64.67 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 64.67 m
- From
- 15.33 m
- To
- 80 m
- Intercept Depth
- 15.33 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:15.33-80
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.01 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: PML-26-072
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · goldGrade: 0.82Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.82
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 16 m
- To
- 18 m
- Intercept Depth
- 16 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:16-18
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.82 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 1.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.82”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · silverGrade: 24.85Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 24.85
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 16 m
- To
- 18 m
- Intercept Depth
- 16 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:16-18
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 24.85 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 49.7 g/t·m is below.
Negative factors
- 24.85 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“24.85”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · palladiumGrade: 0.11Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 16 m
- To
- 18 m
- Intercept Depth
- 16 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:16-18
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.11 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.11”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · platinumGrade: 0Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 16 m
- To
- 18 m
- Intercept Depth
- 16 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:16-18
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.00”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · nickelGrade: 0.01Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 2 m
- From
- 16 m
- To
- 18 m
- Intercept Depth
- 16 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:16-18
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.01 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · goldGrade: 0.48Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.48
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 39.5 m
- To
- 41.5 m
- Intercept Depth
- 39.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:39.5-41.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.48 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.48”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · silverGrade: 8.46Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 8.46
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 39.5 m
- To
- 41.5 m
- Intercept Depth
- 39.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:39.5-41.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 8.46 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.9 g/t·m is below.
Negative factors
- 8.46 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.46”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · palladiumGrade: 1.94Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.94
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 39.5 m
- To
- 41.5 m
- Intercept Depth
- 39.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:39.5-41.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.94 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.94”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · platinumGrade: 0Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 39.5 m
- To
- 41.5 m
- Intercept Depth
- 39.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:39.5-41.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.00”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · nickelGrade: 0.02Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 2 m
- From
- 39.5 m
- To
- 41.5 m
- Intercept Depth
- 39.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:39.5-41.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.02 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · goldGrade: 0.62Grade Unit: g/tIntercept: 5.27 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.62
- Grade Unit
- g/t
- Intercept
- 5.27 m
- From
- 56 m
- To
- 61.27 m
- Intercept Depth
- 56 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:56-61.27
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.62 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 3.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.62”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · silverGrade: 17.58Grade Unit: g/tIntercept: 5.27 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 17.58
- Grade Unit
- g/t
- Intercept
- 5.27 m
- From
- 56 m
- To
- 61.27 m
- Intercept Depth
- 56 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:56-61.27
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 17.58 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 92.6 g/t·m is below.
Negative factors
- 17.58 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“17.58”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · palladiumGrade: 0.03Grade Unit: g/tIntercept: 5.27 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 5.27 m
- From
- 56 m
- To
- 61.27 m
- Intercept Depth
- 56 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:56-61.27
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.03 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.03”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · platinumGrade: 0Grade Unit: g/tIntercept: 5.27 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 5.27 m
- From
- 56 m
- To
- 61.27 m
- Intercept Depth
- 56 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:56-61.27
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.00”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-072Lion Zone · nickelGrade: 0.01Grade Unit: %Intercept: 5.27 mView all detailsHide details
Identity
- Hole ID
- PML-26-072
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 5.27 m
- From
- 56 m
- To
- 61.27 m
- Intercept Depth
- 56 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-072:56-61.27
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.01 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: and including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · goldGrade: 0.21Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 90 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:90-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 4.2 g/t·m is below.
Negative factors
- 0.21 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: PML-26-077
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · silverGrade: 5.08Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 5.08
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 90 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:90-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 5.08 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 101.6 g/t·m is below.
Negative factors
- 5.08 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.08”
Context: PML-26-077
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · palladiumGrade: 0.24Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 90 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:90-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.24 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.24”
Context: PML-26-077
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · platinumGrade: 0.02Grade Unit: g/tIntercept: 20 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 20 m
- From
- 90 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:90-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.02”
Context: PML-26-077
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · nickelGrade: 0.01Grade Unit: %Intercept: 20 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 20 m
- From
- 90 m
- To
- 110 m
- Intercept Depth
- 90 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:90-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.01 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: PML-26-077
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · goldGrade: 0.27Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 108 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below.
Negative factors
- 0.27 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · silverGrade: 6.36Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 6.36
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 108 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 6.36 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 12.7 g/t·m is below.
Negative factors
- 6.36 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.36”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · palladiumGrade: 2.16Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 2.16
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 108 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 2.16 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“2.16”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · platinumGrade: 0.16Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 108 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.16 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.16”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-077Lion Zone · nickelGrade: 0.06Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- PML-26-077
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 2 m
- From
- 108 m
- To
- 110 m
- Intercept Depth
- 108 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-077:108-110
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.06 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · goldGrade: 1.17Grade Unit: g/tIntercept: 12.35 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.17
- Grade Unit
- g/t
- Intercept
- 12.35 m
- From
- 179 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:179-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 1.17 g/t gold is moderate against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 14.4 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.17”
Context: PML-26-091
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · silverGrade: 4.78Grade Unit: g/tIntercept: 12.35 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 4.78
- Grade Unit
- g/t
- Intercept
- 12.35 m
- From
- 179 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:179-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 4.78 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 59.0 g/t·m is below.
Negative factors
- 4.78 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.78”
Context: PML-26-091
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · palladiumGrade: 0.6Grade Unit: g/tIntercept: 12.35 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.6
- Grade Unit
- g/t
- Intercept
- 12.35 m
- From
- 179 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:179-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.6 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.60”
Context: PML-26-091
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · platinumGrade: 0.02Grade Unit: g/tIntercept: 12.35 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 12.35 m
- From
- 179 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:179-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.02”
Context: PML-26-091
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · nickelGrade: 0.02Grade Unit: %Intercept: 12.35 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 12.35 m
- From
- 179 m
- To
- 191.35 m
- Intercept Depth
- 179 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:179-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.02 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: PML-26-091
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · goldGrade: 3.05Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 3.05
- Grade Unit
- g/t
- Intercept
- 4.5 m
- From
- 186.85 m
- To
- 191.35 m
- Intercept Depth
- 186.85 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:186.85-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 3.05 g/t gold is strong against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 13.7 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 3.05 g/t gold is strong on the open_pit mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.05”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · silverGrade: 4.73Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 4.73
- Grade Unit
- g/t
- Intercept
- 4.5 m
- From
- 186.85 m
- To
- 191.35 m
- Intercept Depth
- 186.85 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:186.85-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 4.73 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 21.3 g/t·m is below.
Negative factors
- 4.73 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.73”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · palladiumGrade: 1.62Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.62
- Grade Unit
- g/t
- Intercept
- 4.5 m
- From
- 186.85 m
- To
- 191.35 m
- Intercept Depth
- 186.85 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:186.85-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.62 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.62”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · platinumGrade: 0.04Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 4.5 m
- From
- 186.85 m
- To
- 191.35 m
- Intercept Depth
- 186.85 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:186.85-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.04 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.04”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-091Lion Zone · nickelGrade: 0.04Grade Unit: %Intercept: 4.5 mView all detailsHide details
Identity
- Hole ID
- PML-26-091
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 4.5 m
- From
- 186.85 m
- To
- 191.35 m
- Intercept Depth
- 186.85 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-091:186.85-191.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.04 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-097Lion Zone · goldGrade: 0.32Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 10.3 m
- From
- 91.5 m
- To
- 101.8 m
- Intercept Depth
- 91.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-097:91.5-101.8
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.32 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 3.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.32”
Context: PML-26-097
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-097Lion Zone · silverGrade: 7.98Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 7.98
- Grade Unit
- g/t
- Intercept
- 10.3 m
- From
- 91.5 m
- To
- 101.8 m
- Intercept Depth
- 91.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-097:91.5-101.8
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 7.98 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 82.2 g/t·m is below.
Negative factors
- 7.98 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.98”
Context: PML-26-097
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-097Lion Zone · palladiumGrade: 6.94Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 6.94
- Grade Unit
- g/t
- Intercept
- 10.3 m
- From
- 91.5 m
- To
- 101.8 m
- Intercept Depth
- 91.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-097:91.5-101.8
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 6.94 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“6.94”
Context: PML-26-097
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-097Lion Zone · platinumGrade: 0.7Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.7
- Grade Unit
- g/t
- Intercept
- 10.3 m
- From
- 91.5 m
- To
- 101.8 m
- Intercept Depth
- 91.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-097:91.5-101.8
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.70”
Context: PML-26-097
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-097Lion Zone · nickelGrade: 0.03Grade Unit: %Intercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- PML-26-097
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 10.3 m
- From
- 91.5 m
- To
- 101.8 m
- Intercept Depth
- 91.5 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-097:91.5-101.8
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.03 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: PML-26-097
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · goldGrade: 0.15Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below.
Negative factors
- 0.15 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · silverGrade: 14.75Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 14.75
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 14.75 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 36.9 g/t·m is below.
Negative factors
- 14.75 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“14.75”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · copperGrade: 0.87Grade Unit: %Intercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.87
- Grade Unit
- %
- Intercept
- 2.5 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.87 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.2 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.87”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · palladiumGrade: 0.02Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.02”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · platinumGrade: 0.01Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.01”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · nickelGrade: 0.11Grade Unit: %Intercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 2.5 m
- From
- 169.8 m
- To
- 172.3 m
- Intercept Depth
- 169.8 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:169.8-172.3
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.11 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · goldGrade: 0.46Grade Unit: g/tIntercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 5.6 m
- From
- 34 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:34-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.46 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 2.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.46”
Context: PML-26-099
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · silverGrade: 16.72Grade Unit: g/tIntercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 16.72
- Grade Unit
- g/t
- Intercept
- 5.6 m
- From
- 34 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:34-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 16.72 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 93.6 g/t·m is below.
Negative factors
- 16.72 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“16.72”
Context: PML-26-099
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · palladiumGrade: 0.82Grade Unit: g/tIntercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.82
- Grade Unit
- g/t
- Intercept
- 5.6 m
- From
- 34 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:34-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.82 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.82”
Context: PML-26-099
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · platinumGrade: 0.83Grade Unit: g/tIntercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.83
- Grade Unit
- g/t
- Intercept
- 5.6 m
- From
- 34 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:34-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.83 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.83”
Context: PML-26-099
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · nickelGrade: 0.02Grade Unit: %Intercept: 5.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 5.6 m
- From
- 34 m
- To
- 39.6 m
- Intercept Depth
- 34 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:34-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.02 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: PML-26-099
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · goldGrade: 0.77Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.77
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 37 m
- To
- 39.6 m
- Intercept Depth
- 37 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:37-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.77 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 2.0 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.77”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · silverGrade: 29.59Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 29.59
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 37 m
- To
- 39.6 m
- Intercept Depth
- 37 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:37-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 29.59 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 76.9 g/t·m is below.
Negative factors
- 29.59 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“29.59”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · palladiumGrade: 1.72Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.72
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 37 m
- To
- 39.6 m
- Intercept Depth
- 37 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:37-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.72 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.72”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · platinumGrade: 1.78Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.78
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 37 m
- To
- 39.6 m
- Intercept Depth
- 37 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:37-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.78 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“1.78”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-099Lion Zone · nickelGrade: 0Grade Unit: %Intercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- PML-26-099
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 2.6 m
- From
- 37 m
- To
- 39.6 m
- Intercept Depth
- 37 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-099:37-39.6
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · goldGrade: 0.27Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 2.2 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 55 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below.
Negative factors
- 0.27 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · silverGrade: 4.89Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 4.89
- Grade Unit
- g/t
- Intercept
- 2.2 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 55 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 4.89 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 10.8 g/t·m is below.
Negative factors
- 4.89 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.89”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · copperGrade: 0.45Grade Unit: %Intercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 2.2 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 55 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.45 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.0 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.45”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · palladiumGrade: 1.07Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.07
- Grade Unit
- g/t
- Intercept
- 2.2 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 55 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.07 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.07”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · platinumGrade: 0.82Grade Unit: g/tIntercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.82
- Grade Unit
- g/t
- Intercept
- 2.2 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 55 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.82 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.82”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · nickelGrade: 0.02Grade Unit: %Intercept: 2.2 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 2.2 m
- From
- 55 m
- To
- 57.2 m
- Intercept Depth
- 55 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:55-57.2
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.02 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · goldGrade: 0.47Grade Unit: g/tIntercept: 10.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.47
- Grade Unit
- g/t
- Intercept
- 10.45 m
- From
- 173.9 m
- To
- 184.35 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:173.9-184.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.47 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 4.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.47”
Context: PML-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · silverGrade: 6.08Grade Unit: g/tIntercept: 10.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 6.08
- Grade Unit
- g/t
- Intercept
- 10.45 m
- From
- 173.9 m
- To
- 184.35 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:173.9-184.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 6.08 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 63.5 g/t·m is below.
Negative factors
- 6.08 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.08”
Context: PML-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · palladiumGrade: 1.63Grade Unit: g/tIntercept: 10.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.63
- Grade Unit
- g/t
- Intercept
- 10.45 m
- From
- 173.9 m
- To
- 184.35 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:173.9-184.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.63 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.63”
Context: PML-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · platinumGrade: 0.42Grade Unit: g/tIntercept: 10.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.42
- Grade Unit
- g/t
- Intercept
- 10.45 m
- From
- 173.9 m
- To
- 184.35 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:173.9-184.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.42 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.42”
Context: PML-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · nickelGrade: 0.51Grade Unit: %Intercept: 10.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.51
- Grade Unit
- %
- Intercept
- 10.45 m
- From
- 173.9 m
- To
- 184.35 m
- Intercept Depth
- 173.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:173.9-184.35
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.51 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.51”
Context: PML-26-102
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · goldGrade: 1.31Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.31
- Grade Unit
- g/t
- Intercept
- 2.8 m
- From
- 174.6 m
- To
- 177.4 m
- Intercept Depth
- 174.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:174.6-177.4
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 1.31 g/t gold is moderate against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 3.7 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.31”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · silverGrade: 15.88Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 15.88
- Grade Unit
- g/t
- Intercept
- 2.8 m
- From
- 174.6 m
- To
- 177.4 m
- Intercept Depth
- 174.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:174.6-177.4
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 15.88 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 44.5 g/t·m is below.
Negative factors
- 15.88 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“15.88”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · palladiumGrade: 1.64Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.64
- Grade Unit
- g/t
- Intercept
- 2.8 m
- From
- 174.6 m
- To
- 177.4 m
- Intercept Depth
- 174.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:174.6-177.4
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.64 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.64”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · platinumGrade: 0.07Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 2.8 m
- From
- 174.6 m
- To
- 177.4 m
- Intercept Depth
- 174.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:174.6-177.4
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.07 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.07”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · nickelGrade: 0.09Grade Unit: %Intercept: 2.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.09
- Grade Unit
- %
- Intercept
- 2.8 m
- From
- 174.6 m
- To
- 177.4 m
- Intercept Depth
- 174.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:174.6-177.4
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.09 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · goldGrade: 0.22Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 178.7 m
- To
- 182.5 m
- Intercept Depth
- 178.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:178.7-182.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.22 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below.
Negative factors
- 0.22 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.22”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · silverGrade: 4.06Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 4.06
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 178.7 m
- To
- 182.5 m
- Intercept Depth
- 178.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:178.7-182.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 4.06 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 15.4 g/t·m is below.
Negative factors
- 4.06 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.06”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · palladiumGrade: 3.08Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 3.08
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 178.7 m
- To
- 182.5 m
- Intercept Depth
- 178.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:178.7-182.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 3.08 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“3.08”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · platinumGrade: 0.98Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.98
- Grade Unit
- g/t
- Intercept
- 3.8 m
- From
- 178.7 m
- To
- 182.5 m
- Intercept Depth
- 178.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:178.7-182.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.98 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.98”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-102Lion Zone · nickelGrade: 1.21Grade Unit: %Intercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- PML-26-102
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.21
- Grade Unit
- %
- Intercept
- 3.8 m
- From
- 178.7 m
- To
- 182.5 m
- Intercept Depth
- 178.7 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-102:178.7-182.5
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 1.21 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.21”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · goldGrade: 0.01Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 4.1 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 197.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.01 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · silverGrade: 9.8Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 9.8
- Grade Unit
- g/t
- Intercept
- 4.1 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 197.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 9.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 40.2 g/t·m is below.
Negative factors
- 9.8 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“9.80”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · copperGrade: 0.54Grade Unit: %Intercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.54
- Grade Unit
- %
- Intercept
- 4.1 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 197.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.54 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.2 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.54”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · palladiumGrade: 0.02Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 4.1 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 197.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.02”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · platinumGrade: 0.02Grade Unit: g/tIntercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 4.1 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 197.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.02 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.02”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
andLion Zone · nickelGrade: 0.09Grade Unit: %Intercept: 4.1 mView all detailsHide details
Identity
- Hole ID
- and
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.09
- Grade Unit
- %
- Intercept
- 4.1 m
- From
- 197.9 m
- To
- 202 m
- Intercept Depth
- 197.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- and:197.9-202
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.09 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: and
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-103Lion Zone · goldGrade: 0.29Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-103
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 93 m
- To
- 94.45 m
- Intercept Depth
- 93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-103:93-94.45
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.29 g/t gold is below against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below.
Negative factors
- 0.29 g/t gold is below the weak threshold (0.3 g/t) on the open_pit mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.29”
Context: PML-26-103
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-103Lion Zone · silverGrade: 10.57Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-103
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 10.57
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 93 m
- To
- 94.45 m
- Intercept Depth
- 93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-103:93-94.45
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 10.57 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 15.3 g/t·m is below.
Negative factors
- 10.57 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.57”
Context: PML-26-103
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-103Lion Zone · palladiumGrade: 0.86Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-103
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 93 m
- To
- 94.45 m
- Intercept Depth
- 93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-103:93-94.45
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.86 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.86”
Context: PML-26-103
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-103Lion Zone · platinumGrade: 0.01Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-103
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 93 m
- To
- 94.45 m
- Intercept Depth
- 93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-103:93-94.45
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.01 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.01”
Context: PML-26-103
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-103Lion Zone · nickelGrade: 0.35Grade Unit: %Intercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- PML-26-103
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.35
- Grade Unit
- %
- Intercept
- 1.45 m
- From
- 93 m
- To
- 94.45 m
- Intercept Depth
- 93 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-103:93-94.45
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.35 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.35”
Context: PML-26-103
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · goldGrade: 0.49Grade Unit: g/tIntercept: 22.71 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.49
- Grade Unit
- g/t
- Intercept
- 22.71 m
- From
- 123 m
- To
- 145.71 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:123-145.71
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.49 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 11.1 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.49”
Context: PML-26-109
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · silverGrade: 9.84Grade Unit: g/tIntercept: 22.71 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 9.84
- Grade Unit
- g/t
- Intercept
- 22.71 m
- From
- 123 m
- To
- 145.71 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:123-145.71
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 9.84 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 223.5 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“9.84”
Context: PML-26-109
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · palladiumGrade: 0.75Grade Unit: g/tIntercept: 22.71 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.75
- Grade Unit
- g/t
- Intercept
- 22.71 m
- From
- 123 m
- To
- 145.71 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:123-145.71
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0.75 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.75”
Context: PML-26-109
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · platinumGrade: 0Grade Unit: g/tIntercept: 22.71 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 22.71 m
- From
- 123 m
- To
- 145.71 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:123-145.71
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.00”
Context: PML-26-109
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · nickelGrade: 0.01Grade Unit: %Intercept: 22.71 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 22.71 m
- From
- 123 m
- To
- 145.71 m
- Intercept Depth
- 123 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:123-145.71
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.01 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: PML-26-109
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · goldGrade: 0.93Grade Unit: g/tIntercept: 8.95 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.93
- Grade Unit
- g/t
- Intercept
- 8.95 m
- From
- 129.05 m
- To
- 138 m
- Intercept Depth
- 129.05 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:129.05-138
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.93 g/t gold is weak against the open_pit mining band [5, 2, 1, 0.3] g/t. Grade×width 8.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.93”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · silverGrade: 15.63Grade Unit: g/tIntercept: 8.95 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- silver
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 15.63
- Grade Unit
- g/t
- Intercept
- 8.95 m
- From
- 129.05 m
- To
- 138 m
- Intercept Depth
- 129.05 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:129.05-138
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 15.63 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 139.9 g/t·m is below.
Negative factors
- 15.63 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“15.63”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · palladiumGrade: 1.18Grade Unit: g/tIntercept: 8.95 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 1.18
- Grade Unit
- g/t
- Intercept
- 8.95 m
- From
- 129.05 m
- To
- 138 m
- Intercept Depth
- 129.05 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:129.05-138
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 1.18 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“1.18”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · platinumGrade: 0Grade Unit: g/tIntercept: 8.95 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0
- Grade Unit
- g/t
- Intercept
- 8.95 m
- From
- 129.05 m
- To
- 138 m
- Intercept Depth
- 129.05 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:129.05-138
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.00”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
PML-26-109Lion Zone · nickelGrade: 0.01Grade Unit: %Intercept: 8.95 mView all detailsHide details
Identity
- Hole ID
- PML-26-109
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- canada
- Ticker
- PNPN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 8.95 m
- From
- 129.05 m
- To
- 138 m
- Intercept Depth
- 129.05 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- PML-26-109:129.05-138
- Mining Method
- open_pit
QA/QC
- Laboratory
- Activation Laboratories Ltd
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.01 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metallurgical Results (5)
locked-cycleLion Zone · copperRecovery: 98.9 %Head Grade: 3.42Head Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Lion Zone
- Commodity
- copper
- Region
- canada
- Reported Region
- Canada
- Ticker
- PNPN
Test Work
- Program Status
- detailed
- Test Type
- locked-cycle
- Processing Route
- flotation
- Sample
- Lion Zone Blended Composite
Recovery
- Recovery
- 98.9 %
- Recovery Basis
- actual_test
- Head Grade
- 3.42
- Head Grade Unit
- %
- Conc. Grade
- 25.8
- Conc. Grade Unit
- %
Lab
- Laboratory
- SGS Canada Ltd.
- Consultant
- SGS Canada Ltd.
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-01-21T00:00:00.000Z
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This historical locked-cycle test shows exceptional copper recovery for the blended composite, indicating strong metallurgical performance for the Lion Zone.
Positive factors
- High Recovery (exceptional for flotation)
- Locked-cycle test (strong test scale maturity)
- Certified lab
Negative factors
- Historical result
Evidence · table
“98.9”
Context: 3.42 %
Tags used in scoring
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: processing_route matches the flotation signal
locked-cycleLion Zone · nickelRecovery: 77.1 %Head Grade: 0.2Head Grade Unit: %Historical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Lion Zone
- Commodity
- nickel
- Region
- canada
- Reported Region
- Canada
- Ticker
- PNPN
Test Work
- Program Status
- detailed
- Test Type
- locked-cycle
- Processing Route
- flotation
- Sample
- Lion Zone Blended Composite
Recovery
- Recovery
- 77.1 %
- Recovery Basis
- actual_test
- Head Grade
- 0.2
- Head Grade Unit
- %
- Conc. Grade
- 1.2
- Conc. Grade Unit
- %
Lab
- Laboratory
- SGS Canada Ltd.
- Consultant
- SGS Canada Ltd.
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-01-21T00:00:00.000Z
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This historical locked-cycle test shows weak nickel recovery for the blended composite, suggesting challenges in nickel flotation for the Lion Zone.
Positive factors
- Locked-cycle test (strong test scale maturity)
- Certified lab
Negative factors
- Low Recovery (weak for flotation)
- Historical result
Evidence · table
“77.1”
Context: 0.20 %
Tags used in scoring
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: processing_route matches the flotation signal
locked-cycleLion Zone · goldRecovery: 85 %Head Grade: 0.7Head Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Lion Zone
- Commodity
- gold
- Region
- canada
- Reported Region
- Canada
- Ticker
- PNPN
Test Work
- Program Status
- detailed
- Test Type
- locked-cycle
- Processing Route
- flotation
- Sample
- Lion Zone Blended Composite
Recovery
- Recovery
- 85 %
- Recovery Basis
- actual_test
- Head Grade
- 0.7
- Head Grade Unit
- g/t
- Conc. Grade
- 4.83
- Conc. Grade Unit
- g/t
Lab
- Laboratory
- SGS Canada Ltd.
- Consultant
- SGS Canada Ltd.
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-01-21T00:00:00.000Z
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This historical locked-cycle test shows moderate gold recovery for the blended composite, indicating reasonable metallurgical performance for the Lion Zone.
Positive factors
- Moderate Recovery (for flotation)
- Locked-cycle test (strong test scale maturity)
- Certified lab
Negative factors
- Historical result
Evidence · table
“85.0”
Context: 0.70 g/t
Tags used in scoring
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: processing_route matches the flotation signal
locked-cycleLion Zone · palladiumRecovery: 93.9 %Head Grade: 5.37Head Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Lion Zone
- Commodity
- palladium
- Region
- canada
- Reported Region
- Canada
- Ticker
- PNPN
Test Work
- Program Status
- detailed
- Test Type
- locked-cycle
- Processing Route
- flotation
- Sample
- Lion Zone Blended Composite
Recovery
- Recovery
- 93.9 %
- Recovery Basis
- actual_test
- Head Grade
- 5.37
- Head Grade Unit
- g/t
- Conc. Grade
- 41.4
- Conc. Grade Unit
- g/t
Lab
- Laboratory
- SGS Canada Ltd.
- Consultant
- SGS Canada Ltd.
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-01-21T00:00:00.000Z
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This historical locked-cycle test shows exceptional palladium recovery for the blended composite, indicating strong metallurgical performance for the Lion Zone.
Positive factors
- High Recovery (exceptional for flotation)
- Locked-cycle test (strong test scale maturity)
- Certified lab
Negative factors
- Historical result
Evidence · table
“93.9”
Context: 5.37 g/t
Tags used in scoring
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: processing_route matches the flotation signal
locked-cycleLion Zone · platinumRecovery: 96.8 %Head Grade: 2.9Head Grade Unit: g/tHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Lion Zone
- Commodity
- platinum
- Region
- canada
- Reported Region
- Canada
- Ticker
- PNPN
Test Work
- Program Status
- detailed
- Test Type
- locked-cycle
- Processing Route
- flotation
- Sample
- Lion Zone Blended Composite
Recovery
- Recovery
- 96.8 %
- Recovery Basis
- actual_test
- Head Grade
- 2.9
- Head Grade Unit
- g/t
- Conc. Grade
- 23.4
- Conc. Grade Unit
- g/t
Lab
- Laboratory
- SGS Canada Ltd.
- Consultant
- SGS Canada Ltd.
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Historical
- Yes
- Historical Source Date
- 2026-01-21T00:00:00.000Z
Dates
- Event date
- 2026-05-26T00:00:00.000Z
Reasoning: This historical locked-cycle test shows exceptional platinum recovery for the blended composite, indicating strong metallurgical performance for the Lion Zone.
Positive factors
- High Recovery (exceptional for flotation)
- Locked-cycle test (strong test scale maturity)
- Certified lab
Negative factors
- Historical result
Evidence · table
“96.8”
Context: 2.90 g/t
Tags used in scoring
Mill Routeneutral
Processing via mill or concentrator (CIL, CIP, tank leach, flotation).
Why it applies: processing_route matches the flotation signal
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.