# Magna Mining Expands the R2 Footwall Zone and Intersects Near Surface Mineralization at the Levack Mine in Sudbury, Ontario including 4.0% Nickel, 1.7% Copper and 3.5 g/t Platinum + Palladium + Gold \(8.3% CuEq\) over 4.6 metres

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde

Original source: https://www.globenewswire.com/news-release/2026/09/17/3363819/0/en/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineralization-at-the-levack-mine-in-sudbury-ontario-including-4-0-nickel-1-7-copper-and-3-5-g-t-platinum-pall.html

Publisher: globenewswire

Original announcement: 2026-09-17T00:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Magna Mining Inc.

- Ticker: NICU

- Exchange: Unavailable

- Region: Ontario, Canada

- Primary commodity: Nickel

- Secondary commodities: Copper, Platinum, Palladium, Gold, Silver, Cobalt

- Document categories: Drill results

- Extracted: 2026-09-18 20:44:15 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

Magna Mining announced new drill results from its Levack Mine in Sudbury, Ontario, highlighting high-grade nickel, copper, and platinum group metals. Drilling expanded the R2 Footwall Zone and intersected significant near-surface mineralization at the West Main Orebody, with assays including 4.0% Nickel, 1.7% Copper, and 3.5 g/t Platinum + Palladium + Gold over 4.6 metres. The company is advancing both underground and surface exploration, with plans to release updated economic studies soon.

Reasoning: The document reports significant high-grade nickel, copper, and PGM intercepts from both deep underground and near-surface drilling, expanding known zones and identifying new potential for early production. The results are well-supported by detailed assay data and transparent metal equivalent calculations.

- Positive factor: High-grade polymetallic intercepts, particularly in the R2 Footwall Zone and West Main Orebody.

- Positive factor: Expansion of the R2 Footwall Zone towards the No.3 Orebody and at depth.

- Positive factor: Discovery of thick, high-grade near-surface mineralization at the West Main Zone, indicating potential for early production.

- Positive factor: Multiple distinct mineralized veins intersected in several holes.

- Positive factor: Clear disclosure of metal equivalent calculation assumptions and QA/QC procedures.

- Negative factor: True widths are highly variable and not explicitly stated for individual intercepts, only a range \(30-80% of downhole length\).

- Negative factor: Some holes returned no significant results, which is typical for exploration but noted.

Facts used in scoring: 384

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 384. Some facts used in scoring do not have a stored record.

## Drill Results (384)

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-0)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.8
- Grade Unit: %
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid copper grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good copper grade over a moderate width.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.8

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-1)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.4
- Grade Unit: %
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid nickel grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good nickel grade over a moderate width.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.4

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-2)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-3)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid platinum grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good platinum grade over a moderate width.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.0

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-4)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid palladium grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good palladium grade over a moderate width.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.7

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-5)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: g/t
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.3

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-6)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 8.1
- Grade Unit: g/t
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 8.1

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-7)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 4 m
- From: 977.7 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 2.0

Context: 4.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-8)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7.8
- Grade Unit: %
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional copper grade, indicating a high-grade vein within the broader intercept.

- Positive factor: Very high copper grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 7.8

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-9)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6.4
- Grade Unit: %
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional nickel grade, indicating a high-grade vein within the broader intercept.

- Positive factor: Very high nickel grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 6.4

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-10)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-11)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.7
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional platinum grade, indicating a high-grade vein within the broader intercept.

- Positive factor: Very high platinum grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 3.7

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-12)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.1
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional palladium grade, indicating a high-grade vein within the broader intercept.

- Positive factor: Very high palladium grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 3.1

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-13)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows a low gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-14)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 20
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows a solid silver grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good silver grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 20.0

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-15)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6.9
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 977.7 m
- To: 978.5 m
- Hole Depth: 1182 m
- Intercept Depth: 977.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:977.7-978.5
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 18
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 6.9 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 6.9

Context: 0.8

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-16)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 10.7
- Grade Unit: %
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional copper grade, indicating a very high-grade vein within the broader intercept.

- Positive factor: Exceptional copper grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 10.7

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-17)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows a solid nickel grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good nickel grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.6

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-18)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-19)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows a solid platinum grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.7

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-20)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows a solid palladium grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.7

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-21)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.8
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional gold grade, indicating a high-grade vein within the broader intercept.

- Positive factor: High gold grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.8

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-22)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 32
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This sub-interval shows a solid silver grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good silver grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 32.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-23)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5.2
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 981.3 m
- To: 981.7 m
- Hole Depth: 1182 m
- Intercept Depth: 981.3 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:981.3-981.7
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 13.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 5.2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 5.2

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-24)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 9.5
- Grade Unit: %
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional copper grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional copper grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 9.5

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-25)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.6
- Grade Unit: %
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional nickel grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional nickel grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.6

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-26)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-27)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.2
- Grade Unit: g/t
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing significantly to the overall polymetallic value.

- Positive factor: Very high platinum grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 3.2

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-28)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional palladium grade, contributing significantly to the overall polymetallic value.

- Positive factor: Very high palladium grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.0

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-29)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 12.2
- Grade Unit: g/t
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional gold grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional gold grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 12.2

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-30)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 24.9
- Grade Unit: g/t
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid silver grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good silver grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 24.9

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-31)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 17.5
- Grade Unit: g/t
- Intercept: 2.1 m
- From: 999.2 m
- To: 1001.3 m
- Hole Depth: 1182 m
- Intercept Depth: 999.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:999.2-1001.3
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 23.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 17.5 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 17.5

Context: 2.1

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-32)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional copper grade, contributing to the overall polymetallic value.

- Positive factor: Exceptional copper grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 4.2

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-33)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.5
- Grade Unit: %
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional nickel grade, contributing to the overall polymetallic value.

- Positive factor: Exceptional nickel grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.5

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-34)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-35)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing to the overall polymetallic value.

- Positive factor: Exceptional platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.2

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-36)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional palladium grade, contributing to the overall polymetallic value.

- Positive factor: Exceptional palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.1

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-37)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.3

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-38)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 16
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid silver grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good silver grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 16.0

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-39)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 1038.5 m
- To: 1039 m
- Hole Depth: 1182 m
- Intercept Depth: 1038.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1038.5-1039
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.6 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 4.6

Context: 0.5

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-40)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: %
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid copper grade, contributing to the overall polymetallic value.

- Positive factor: Good copper grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.9

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-41)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.4
- Grade Unit: %
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid nickel grade, contributing to the overall polymetallic value.

- Positive factor: Good nickel grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.4

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-42)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-43)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid platinum grade, contributing to the overall polymetallic value.

- Positive factor: Good platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.3

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-44)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid palladium grade, contributing to the overall polymetallic value.

- Positive factor: Good palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-45)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-46)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 7.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-47)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.3
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1052.6 m
- To: 1053 m
- Hole Depth: 1182 m
- Intercept Depth: 1052.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1052.6-1053
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.3 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 2.3

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-48)

Levack · copper

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 15.4
- Grade Unit: %
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional copper grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional copper grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 15.4

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-49)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: %
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid nickel grade, contributing to the overall polymetallic value.

- Positive factor: Good nickel grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.9

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-50)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-51)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.7
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional platinum grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.7

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-52)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.2
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional palladium grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional palladium grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 4.2

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-53)

Levack · gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-54)

Levack · silver

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 43
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid silver grade, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good silver grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 43.0

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W1

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-55)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W1
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 1068.6 m
- To: 1069.2 m
- Hole Depth: 1182 m
- Intercept Depth: 1068.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W1:1068.6-1069.2
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 19.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 7.0

Context: 0.7

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-56)

Levack · copper

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid copper grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good copper grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.7

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-57)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.5
- Grade Unit: %
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional nickel grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional nickel grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.5

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-58)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low cobalt grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Cobalt grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-59)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional platinum grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 3.4

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-60)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional palladium grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional palladium grade over a narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.3

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-61)

Levack · gold

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-62)

Levack · silver

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low silver grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.0

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-63)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 1012.4 m
- To: 1013.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1012.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1012.4-1013.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 5.8 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 5.8

Context: 1.0

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-64)

Levack · copper

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid copper grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good copper grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.6

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-65)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.9
- Grade Unit: %
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional nickel grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional nickel grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.9

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-66)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-67)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.2
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.2

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-68)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.1
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional palladium grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 4.1

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-69)

Levack · gold

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Gold grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-70)

Levack · silver

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low silver grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.0

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-71)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6.4
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1017.7 m
- To: 1018.4 m
- Hole Depth: 1180 m
- Intercept Depth: 1017.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1017.7-1018.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 6.4 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 6.4

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-72)

Levack · copper

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low copper grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Copper grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.3

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-73)

Levack · nickel

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.6
- Grade Unit: %
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional nickel grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional nickel grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 4.6

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-74)

Levack · cobalt

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low cobalt grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Cobalt grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.1

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-75)

Levack · platinum

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.1
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing significantly to the overall polymetallic value.

- Positive factor: Exceptional platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 4.1

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-76)

Levack · palladium

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid palladium grade, contributing to the overall polymetallic value.

- Positive factor: Good palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.7

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-77)

Levack · gold

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good gold grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.5

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-78)

Levack · silver

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low silver grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.0

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX2038-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-79)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX2038-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6.3
- Grade Unit: g/t
- Intercept: 0.6 m
- From: 1048.4 m
- To: 1049 m
- Hole Depth: 1180 m
- Intercept Depth: 1048.4 m

#### Classification

- Sample Type: drill
- Group ID: FNX2038-W2:1048.4-1049
- Mining Method: underground

#### Location

- Location: R2
- Easting: 471667
- Northing: 5167001
- Elevation: 398 m
- Azimuth: 98 °
- Dip: 59 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 6.3 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 6.3

Context: 0.6

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-80)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.8
- Grade Unit: %
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid copper grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good copper grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.8

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-81)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low nickel grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Nickel grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.2

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-82)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-83)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.2
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional platinum grade, contributing to the overall polymetallic value.

- Positive factor: Exceptional platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.2

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-84)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows an exceptional palladium grade, contributing to the overall polymetallic value.

- Positive factor: Exceptional palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 2.5

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-85)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid gold grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good gold grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.5

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-86)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low silver grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Silver grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 6.0

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-87)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5.2
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 788 m
- To: 788.4 m
- Hole Depth: 1145 m
- Intercept Depth: 788 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:788-788.4
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 5.2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 5.2

Context: 0.4

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-88)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Hole Depth: 1145 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid copper grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Good copper grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.1

Context: 0.3

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-89)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Hole Depth: 1145 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a low nickel grade within the R2 Footwall Zone, contributing to the overall polymetallic nature of the mineralization.

- Positive factor: Nickel grade contributes to the overall polymetallic value.

- Negative factor: True width not explicitly stated.

Evidence · table

> 0.3

Context: 0.3

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-90)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Hole Depth: 1145 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Cobalt grade is reported as 0.0%, indicating no significant presence in this interval.

Evidence · table

> 0.0

Context: 0.3

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-91)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Hole Depth: 1145 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid platinum grade, contributing to the overall polymetallic value.

- Positive factor: Good platinum grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.3

Context: 0.3

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-92)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Hole Depth: 1145 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: R2
- Easting: 472109
- Northing: 5166291
- Elevation: 339 m
- Azimuth: 17 °
- Dip: 72 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: This intercept shows a solid palladium grade, contributing to the overall polymetallic value.

- Positive factor: Good palladium grade over a very narrow interval.

- Negative factor: True width not explicitly stated.

Evidence · table

> 1.0

Context: 0.3

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-93)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 1.5 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-94)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 9
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.7 g/t·m is below.

- Negative factor: 9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-95)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.8
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1035.7 m
- To: 1036.1 m
- Intercept Depth: 1035.7 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1035.7-1036.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.8 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 3.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-96)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: %
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.6 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.2 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-97)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % nickel is below against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: 0.2 % nickel is below the weak threshold \(0.3 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-98)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-99)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: g/t
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.4 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-100)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: g/t
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.4 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-101)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.2
- Grade Unit: g/t
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.2 g/t gold is moderate against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 5.5 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-102)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 11
- Grade Unit: g/t
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 11 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 14.3 g/t·m is below.

- Negative factor: 11 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-103)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5
- Grade Unit: g/t
- Intercept: 1.3 m
- From: 1046 m
- To: 1047.3 m
- Intercept Depth: 1046 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1046-1047.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 5.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-104)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.2
- Grade Unit: %
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.2 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 20.9 %·m is weak \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.2 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-105)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % nickel is below against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: 0.2 % nickel is below the weak threshold \(0.3 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-106)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-107)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-108)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 2.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-109)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 9.5 g/t·m is below.

- Negative factor: 1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-110)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 13.6
- Grade Unit: g/t
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 13.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 129.2 g/t·m is below.

- Negative factor: 13.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-111)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.3
- Grade Unit: g/t
- Intercept: 9.5 m
- From: 1050.5 m
- To: 1060 m
- Intercept Depth: 1050.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1050.5-1060
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.3 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 4.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-112)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 26
- Grade Unit: %
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 26 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 10.4 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 26 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 26.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-113)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.5
- Grade Unit: %
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 1.5 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-114)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-115)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.1 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-116)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 11.8
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 11.8 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 11.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-117)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t gold is weak against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 1.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-118)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 146
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 146 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 58.4 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 146.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-119)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 15.5
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 1053 m
- To: 1053.4 m
- Intercept Depth: 1053 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1053-1053.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 31.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 15.5 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 15.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-120)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 13.3
- Grade Unit: %
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 13.3 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 4.0 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 13.3 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-121)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.6
- Grade Unit: %
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 1.6 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-122)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-123)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-124)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 11.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 11.5 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 11.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-125)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 12.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 12.5 g/t gold is strong against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 3.8 g/t·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 12.5 g/t gold is strong on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-126)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 78
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 78 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 23.4 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 78.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-127)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 25.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 1057.6 m
- To: 1057.9 m
- Intercept Depth: 1057.6 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1057.6-1057.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 27.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 25.2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 25.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-128)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 13
- Grade Unit: %
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 13 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 22.1 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 13 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-129)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: %
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-130)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-131)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.1
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.1 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 4.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-132)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 11.3
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 11.3 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 11.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-133)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t gold is weak against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 6.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-134)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 85.2
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 85.2 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 144.8 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 85.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-135)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 19
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 1071.2 m
- To: 1072.8 m
- Intercept Depth: 1071.2 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.2-1072.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 21.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 19.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-136)

Levack · copper

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 27.3
- Grade Unit: %
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 27.3 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 21.8 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 27.3 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 27.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-137)

Levack · nickel

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4
- Grade Unit: %
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4 % nickel is exceptional against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 4 % nickel is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-138)

Levack · cobalt

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-139)

Levack · platinum

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7.4
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 7.4 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 7.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-140)

Levack · palladium

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 23.5
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 23.5 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 23.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-141)

Levack · gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 1.6 g/t·m is below.

- Negative factor: 2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-142)

Levack · silver

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 175
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 175 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 140.0 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 175.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### FNX6070-W2

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-143)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: FNX6070-W2
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 32.9
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 1071.5 m
- To: 1072.2 m
- Intercept Depth: 1071.5 m

#### Classification

- Sample Type: drill
- Group ID: FNX6070-W2:1071.5-1072.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 40.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 32.9 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 32.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-144)

Levack · copper

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-145)

Levack · nickel

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % nickel is below against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: 0.1 % nickel is below the weak threshold \(0.3 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-146)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-147)

Levack · platinum

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 4.2

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-148)

Levack · palladium

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.3
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.3 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 3.3

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-149)

Levack · gold

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.2 g/t·m is below.

- Negative factor: 0.6 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.6

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-150)

Levack · silver

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 16
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 16 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.8 g/t·m is below.

- Negative factor: 16 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.0

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-151)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 8.1
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 98.1 m
- To: 98.4 m
- Intercept Depth: 98.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:98.1-98.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 8.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 8.1

Context: MLV-26-46

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-152)

Levack · copper

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-153)

Levack · nickel

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % nickel is below against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: 0.1 % nickel is below the weak threshold \(0.3 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-154)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-155)

Levack · platinum

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.7
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 3.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-156)

Levack · palladium

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.4
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.4 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 4.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-157)

Levack · gold

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 1.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-158)

Levack · silver

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 22
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 22 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.6 g/t·m is below.

- Negative factor: 22 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 22.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-46

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-159)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-46
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 9.3
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 99.7 m
- To: 100 m
- Intercept Depth: 99.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-46:99.7-100
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 9.3 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 9.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-160)

Levack · copper

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.8
- Grade Unit: %
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.4 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 2.8 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.8

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-161)

Levack · nickel

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % nickel is weak against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-162)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-163)

Levack · platinum

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 2.0

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-164)

Levack · palladium

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.3 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.3

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-165)

Levack · gold

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.3 g/t·m is below.

- Negative factor: 0.7 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.7

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-166)

Levack · silver

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.5 g/t·m is below.

- Negative factor: 5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.0

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-49

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-167)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-49
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 51.8 m
- To: 52.3 m
- Intercept Depth: 51.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-49:51.8-52.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.9 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 3.9

Context: MLV-26-49

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-168)

Levack · copper

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-169)

Levack · nickel

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % nickel is moderate against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.1

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-170)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-171)

Levack · platinum

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: g/t
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.5 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.5

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-172)

Levack · palladium

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.5 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.5

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-173)

Levack · gold

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.2 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-174)

Levack · silver

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.4
- Grade Unit: g/t
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.4 g/t·m is below.

- Negative factor: 3.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.4

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-175)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.1
- Grade Unit: g/t
- Intercept: 1.6 m
- From: 60.5 m
- To: 62.1 m
- Intercept Depth: 60.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:60.5-62.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 2.1

Context: MLV-26-50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-176)

Levack · copper

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-177)

Levack · nickel

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.1
- Grade Unit: %
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.1 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-178)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-179)

Levack · platinum

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.3 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-180)

Levack · palladium

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.3
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.3 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 2.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-181)

Levack · gold

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-182)

Levack · silver

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.2 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-50

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-183)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-50
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.6
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 73.8 m
- To: 74.2 m
- Intercept Depth: 73.8 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-50:73.8-74.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.6 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 3.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-184)

Levack · copper

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: %
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 2.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.0

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-185)

Levack · nickel

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.6
- Grade Unit: %
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.6 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.6

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-186)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-187)

Levack · platinum

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 2.0

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-188)

Levack · palladium

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.1
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.1 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 3.1

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-189)

Levack · gold

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.3 g/t·m is below.

- Negative factor: 0.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-190)

Levack · silver

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7.7
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.8 g/t·m is below.

- Negative factor: 7.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.7

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-191)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5.3
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 34 m
- To: 35.4 m
- Intercept Depth: 34 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:34-35.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 5.3 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 5.3

Context: MLV-26-51

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-192)

Levack · copper

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: %
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.4 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.2 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-193)

Levack · nickel

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: %
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % nickel is moderate against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-194)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-195)

Levack · platinum

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.5 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-196)

Levack · palladium

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.5 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-197)

Levack · gold

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-198)

Levack · silver

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.1 g/t·m is below.

- Negative factor: 7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-51

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-199)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-51
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 24.4 m
- To: 24.7 m
- Intercept Depth: 24.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-51:24.4-24.7
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-200)

Levack · copper

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.9 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.1 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.1

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-201)

Levack · nickel

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.8
- Grade Unit: %
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.8 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 1.8 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.8

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-202)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-203)

Levack · platinum

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.2

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-204)

Levack · palladium

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.3 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.3

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-205)

Levack · gold

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.3 g/t·m is below.

- Negative factor: 0.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-206)

Levack · silver

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.3
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.6 g/t·m is below.

- Negative factor: 3.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.3

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-52

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-207)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-52
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 42.5 m
- To: 44.3 m
- Intercept Depth: 42.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-52:42.5-44.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.7 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.7

Context: MLV-26-52

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-208)

Levack · copper

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.4
- Grade Unit: %
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 2.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.4 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.4

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-209)

Levack · nickel

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % nickel is weak against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.6

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-210)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-211)

Levack · platinum

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.9 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.9

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-212)

Levack · palladium

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.9 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.9

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-213)

Levack · gold

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-214)

Levack · silver

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.2
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.9 g/t·m is below.

- Negative factor: 4.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.2

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-53

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-215)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-53
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.9
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 35.2 m
- To: 36.6 m
- Intercept Depth: 35.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-53:35.2-36.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.9 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 2.9

Context: MLV-26-53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-216)

Levack · copper

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.3
- Grade Unit: %
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 9.6 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.3 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.3

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-217)

Levack · nickel

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.8
- Grade Unit: %
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % nickel is moderate against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.8

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-218)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-219)

Levack · platinum

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.9 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.9

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-220)

Levack · palladium

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.6 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.6

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-221)

Levack · gold

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-222)

Levack · silver

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.3
- Grade Unit: g/t
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 31.8 g/t·m is below.

- Negative factor: 4.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.3

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-223)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.6
- Grade Unit: g/t
- Intercept: 7.4 m
- From: 91.9 m
- To: 99.2 m
- Intercept Depth: 91.9 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:91.9-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.6 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 2.6

Context: MLV-26-54

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-224)

Levack · copper

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7.2
- Grade Unit: %
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7.2 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 5.8 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 7.2 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-225)

Levack · nickel

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.4
- Grade Unit: %
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.4 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-226)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-227)

Levack · platinum

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.8
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.8 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 2.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-228)

Levack · palladium

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.5 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 3.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-229)

Levack · gold

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.2 g/t·m is below.

- Negative factor: 0.3 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-230)

Levack · silver

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 22.8
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 22.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 18.2 g/t·m is below.

- Negative factor: 22.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 22.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-231)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6.6
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 98.5 m
- To: 99.2 m
- Intercept Depth: 98.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:98.5-99.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 12.1
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 6.6 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 6.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-232)

Levack · copper

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 15.3
- Grade Unit: %
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 15.3 % copper is exceptional against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 4.6 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 15.3 % copper is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 15.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-233)

Levack · nickel

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % nickel is weak against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-234)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-235)

Levack · platinum

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-236)

Levack · palladium

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 8.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 8.5 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 8.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-237)

Levack · gold

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t gold is moderate against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 1.8 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-238)

Levack · silver

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 58
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 58 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 17.4 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 58.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-54

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-239)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-54
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 16.2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 424 m
- To: 424.3 m
- Intercept Depth: 424 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-54:424-424.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 22.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 16.2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 16.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-240)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % copper is moderate against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.2 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.6

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-241)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.1
- Grade Unit: %
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.1 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.1

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-242)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-243)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.7

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-244)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.9 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.9

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-245)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.3 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.3

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-246)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.0

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-247)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.8
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 31.7 m
- To: 32 m
- Intercept Depth: 31.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:31.7-32
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.8 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.8

Context: MLV-26-58

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-248)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.4
- Grade Unit: %
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 3.2 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.4 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-249)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 % nickel is weak against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-250)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-251)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: g/t
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.4 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-252)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.4
- Grade Unit: g/t
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.4 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-253)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.2 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-254)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5.2
- Grade Unit: g/t
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 12.0 g/t·m is below.

- Negative factor: 5.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-255)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.8
- Grade Unit: g/t
- Intercept: 2.3 m
- From: 73.2 m
- To: 75.5 m
- Intercept Depth: 73.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:73.2-75.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.8 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-256)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.4 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.1 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-257)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: %
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % nickel is moderate against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-258)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-259)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.8 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-260)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.9 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-261)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-262)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.8 g/t·m is below.

- Negative factor: 7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-263)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 0.4 m
- From: 93.1 m
- To: 93.6 m
- Intercept Depth: 93.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:93.1-93.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.7 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-264)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.5
- Grade Unit: %
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.5 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-265)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % nickel is weak against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-266)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-267)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-268)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.2 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 3.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-269)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-270)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.5 g/t·m is below.

- Negative factor: 9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-271)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 112.5 m
- To: 113 m
- Intercept Depth: 112.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:112.5-113
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 4.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-272)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-273)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.3
- Grade Unit: %
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 % nickel is exceptional against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 3.3 % nickel is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-274)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-275)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.5 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 2.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-276)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 4.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-277)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-278)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-279)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 6.6
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 126.3 m
- To: 126.6 m
- Intercept Depth: 126.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:126.3-126.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 6.6
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 6.6 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 6.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-280)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.4
- Grade Unit: %
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.2 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.4 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-281)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % nickel is weak against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-282)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-283)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-284)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.9 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-285)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-286)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 11
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 11 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.5 g/t·m is below.

- Negative factor: 11 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-287)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 134.7 m
- To: 135.2 m
- Intercept Depth: 134.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:134.7-135.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.7 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-288)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: %
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.2 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-289)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.5
- Grade Unit: %
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 1.5 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-290)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-291)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.4
- Grade Unit: g/t
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.4 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-292)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.9 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-293)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-294)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.8
- Grade Unit: g/t
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.6 g/t·m is below.

- Negative factor: 3.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-295)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 1.2 m
- From: 147.4 m
- To: 148.6 m
- Intercept Depth: 147.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:147.4-148.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.5 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 3.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-296)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.4
- Grade Unit: %
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 9.1 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.4 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-297)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.7
- Grade Unit: %
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.7 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.7 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-298)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-299)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 2.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-300)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.4
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.4 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 2.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-301)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-302)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 7.4
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 7.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 28.1 g/t·m is below.

- Negative factor: 7.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-303)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.5
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 155.3 m
- To: 159.1 m
- Intercept Depth: 155.3 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:155.3-159.1
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 7.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 4.5 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 4.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-304)

Levack · copper

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.6 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.2 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-305)

Levack · nickel

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % nickel is moderate against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-306)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-307)

Levack · platinum

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 3.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-308)

Levack · palladium

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 2.2 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 2.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-309)

Levack · gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-310)

Levack · silver

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.5 g/t·m is below.

- Negative factor: 5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-58

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-311)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-58
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 5.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 166 m
- To: 166.5 m
- Intercept Depth: 166 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-58:166-166.5
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 5.4 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 5.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-312)

Levack · copper

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 3.0 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-313)

Levack · nickel

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.3
- Grade Unit: %
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.3 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.3

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-314)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-315)

Levack · platinum

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.0

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-316)

Levack · palladium

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.0

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-317)

Levack · gold

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-318)

Levack · silver

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 7.5 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-319)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 7.5 m
- From: 189.2 m
- To: 196.6 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.1

Context: MLV-26-60

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-320)

Levack · copper

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-321)

Levack · nickel

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.2
- Grade Unit: %
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.2 % nickel is exceptional against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 3.2 % nickel is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-322)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-323)

Levack · platinum

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-324)

Levack · palladium

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-325)

Levack · gold

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-326)

Levack · silver

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.7 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-327)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 2.7 m
- From: 189.2 m
- To: 191.9 m
- Intercept Depth: 189.2 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:189.2-191.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.8
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-328)

Levack · copper

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % copper is moderate against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 1.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.6

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-329)

Levack · nickel

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.3
- Grade Unit: %
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 % nickel is exceptional against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 3.3 % nickel is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.3

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-330)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-331)

Levack · platinum

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-332)

Levack · palladium

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-333)

Levack · gold

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-334)

Levack · silver

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.2 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-60

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-335)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-60
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 2.2 m
- From: 194.4 m
- To: 196.6 m
- Intercept Depth: 194.4 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-60:194.4-196.6
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-336)

Levack · copper

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: %
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 7.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.7 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.7

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-337)

Levack · nickel

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4
- Grade Unit: %
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4 % nickel is exceptional against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 4 % nickel is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.0

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-338)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % cobalt is moderate against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-339)

Levack · platinum

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.5 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 1.5

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-340)

Levack · palladium

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.9 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.9

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-341)

Levack · gold

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 0.2 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-342)

Levack · silver

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 4.1
- Grade Unit: g/t
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 4.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 18.9 g/t·m is below.

- Negative factor: 4.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.1

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-64

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-343)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-64
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 4.6 m
- From: 198.7 m
- To: 203.3 m
- Intercept Depth: 198.7 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-64:198.7-203.3
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 8.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 3.5 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 3.5

Context: MLV-26-64

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-344)

Levack · copper

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 2.7 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-345)

Levack · nickel

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.3
- Grade Unit: %
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 % nickel is moderate against the default band \[3, 1.5, 0.8, 0.3\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.3

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-346)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-347)

Levack · platinum

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.1

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-348)

Levack · palladium

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.1

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-349)

Levack · gold

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-350)

Levack · silver

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.7 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-65

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-351)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-65
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.3
- Grade Unit: g/t
- Intercept: 6.7 m
- From: 178.1 m
- To: 184.8 m
- Intercept Depth: 178.1 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-65:178.1-184.8
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.3
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.3 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.3

Context: MLV-26-65

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-352)

Levack · copper

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 13.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.4

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-353)

Levack · nickel

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.7
- Grade Unit: %
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 1.7 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.7

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-354)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-355)

Levack · platinum

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.2

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-356)

Levack · palladium

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.2 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.2

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-357)

Levack · gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-358)

Levack · silver

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 36.2 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.1

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-359)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.4
- Grade Unit: g/t
- Intercept: 32.9 m
- From: 177 m
- To: 209.9 m
- Intercept Depth: 177 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:177-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 2.9
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.4 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.4

Context: MLV-26-68

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-360)

Levack · copper

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.6 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-361)

Levack · nickel

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 3.2
- Grade Unit: %
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 3.2 % nickel is exceptional against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 3.2 % nickel is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-362)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-363)

Levack · platinum

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-364)

Levack · palladium

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-365)

Levack · gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-366)

Levack · silver

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.2 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-367)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 3.2 m
- From: 178 m
- To: 181.2 m
- Intercept Depth: 178 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:178-181.2
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 4.7
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-368)

Levack · copper

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % copper is moderate against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 7.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.5

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-369)

Levack · nickel

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: %
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 1.9 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-370)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % cobalt is below against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: 0 % cobalt is below the weak threshold \(0.08 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-371)

Levack · platinum

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-372)

Levack · palladium

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.1 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-373)

Levack · gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-374)

Levack · silver

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 16.5 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-375)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.2
- Grade Unit: g/t
- Intercept: 15 m
- From: 189.5 m
- To: 204.4 m
- Intercept Depth: 189.5 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:189.5-204.4
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 3.2
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.2 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 0.2

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-376)

Levack · copper

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1
- Grade Unit: %
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % copper is strong against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 3.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1 % copper is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.0

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-377)

Levack · nickel

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: nickel
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 2.9
- Grade Unit: %
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 % nickel is strong against the default band \[3, 1.5, 0.8, 0.3\] %.

- Positive factor: 2.9 % nickel is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-378)

Levack · cobalt

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: cobalt
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % cobalt is weak against the default band \[0.5, 0.3, 0.15, 0.08\] %.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-379)

Levack · platinum

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 0.7 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum; intercept not scored.

Evidence · table

> 0.7

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-380)

Levack · palladium

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: palladium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.1 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for palladium; intercept not scored.

Evidence · table

> 1.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-381)

Levack · gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the underground mining band \[15, 7, 4, 2.5\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(2.5 g/t\) on the underground mining band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.1

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-382)

Levack · silver

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.8
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table. 1.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.8 g/t·m is below.

- Negative factor: 1.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.8

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### MLV-26-68

[Link to this fact](https://atlas-extractions.minestarters.com/news/magna-mining-expands-the-r2-footwall-zone-and-intersects-near-surface-mineraliza--e340b2ac-6c23-4b54-a3bb-06be024a3dde#fact-drill-facts-383)

Levack · platinum+palladium+gold

#### Identity

- Hole ID: MLV-26-68
- Project: Levack
- Commodity: platinum+palladium+gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: NICU

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 3.8 m
- From: 206 m
- To: 209.9 m
- Intercept Depth: 206 m

#### Classification

- Sample Type: drill
- Group ID: MLV-26-68:206-209.9
- Mining Method: underground

#### Location

- Location: Main Zone
- Loc. Source: document

#### QA/QC

- Laboratory: SGS Laboratories
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Metal Eq. Grade: 5.5
- Metal Eq. Unit: % CuEq
- Assumptions Disclosed: Yes

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-09-17T00:00:00.000Z

Reasoning: Expanded from assay table: 1.9 g/t platinum+palladium+gold. No grade band defined for this commodity, so the score is a placeholder.

- Negative factor: No grade rubric for platinum+palladium+gold; intercept not scored.

Evidence · table

> 1.9

Context: Table 1: Summary of Drillhole Results

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.