Magna Mining Reports Multiple Copper, Nickel and Precious Metal Rich Intersections from the R2 Target at the Levack Mine in Sudbury, Ontario
Original announcement by tmx on
- Company
- Magna Mining Inc.
- Ticker
- NICU
- Exchange
- TSX
- Region
- Ontario
- Primary commodity
- Copper
- Secondary commodities
- Nickel, Cobalt, Platinum, Palladium, Gold, Silver
- Document categories
- Drill results
- Extracted
- 2026-09-14 15:21:49 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Magna Mining reported high-grade copper, nickel, and precious metal drill results from the R2 Target at its Levack Mine in Sudbury, Ontario. New drillhole FNX6083-W2 intersected multiple mineralized intervals, including 19.27% Cu, 0.26% Ni, and 26.12 g/t Pt+Pd+Au over 0.51 metres, and 4.91% Cu, 12.36% Ni, and 24.18 g/t Pt+Pd+Au over 0.41 metres. The company also received additional high-grade silver assays for previously reported drillholes.
Reasoning: Drillhole FNX6083-W2 returned multiple high-grade copper, nickel, and precious metal intercepts, including bonanza grades of 19.27% Cu, 12.36% Ni, and 26.12 g/t Pt+Pd+Au, extending the R2 target mineralization. The results are from a new hole and include additional silver assays for previously reported holes.
Positive factors
- Bonanza Intercept
- Step-Out Extension
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 124
Extracted facts
Stored fact records: 124. Some facts used in scoring do not have a stored record.
Drill Results (124)
MLV-25-14ALevack Mine · copperGrade: 0.33Grade Unit: %Intercept: 15.29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of moderate grade and width, but is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.33”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · nickelGrade: 0.8Grade Unit: %Intercept: 15.29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.8
- Grade Unit
- %
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 0.96
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade and width, but is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.80”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · cobaltGrade: 0.03Grade Unit: %Intercept: 15.29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and moderate width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.03”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · platinumGrade: 0.2Grade Unit: g/tIntercept: 15.29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of low grade and moderate width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.20”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · palladiumGrade: 0.2Grade Unit: g/tIntercept: 15.29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of low grade and moderate width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.20”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · goldGrade: 0.02Grade Unit: g/tIntercept: 15.29 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and moderate width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.02”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · silverGrade: 1.18Grade Unit: g/tIntercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.18
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:340.26-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of low grade and moderate width, but represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“1.18”
Context: 15.29
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14ALevack Mine · copperGrade: 0.56Grade Unit: %Intercept: 4.73 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.56
- Grade Unit
- %
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.5
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of moderate grade and narrow width, but is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.56”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · nickelGrade: 1.09Grade Unit: %Intercept: 4.73 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.09
- Grade Unit
- %
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.4
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade and narrow width, but is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.09”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · cobaltGrade: 0.04Grade Unit: %Intercept: 4.73 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.04”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · platinumGrade: 0.41Grade Unit: g/tIntercept: 4.73 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.41”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · palladiumGrade: 0.46Grade Unit: g/tIntercept: 4.73 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.46”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · goldGrade: 0.04Grade Unit: g/tIntercept: 4.73 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.04”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · silverGrade: 1.59Grade Unit: g/tIntercept: 4.73 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.59
- Grade Unit
- g/t
- Intercept
- 4.73 m
- From
- 350.82 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:350.82-355.55
- Mining Method
- underground
Location
- Location
- Levack Contact
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of low grade and narrow width, but represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“1.59”
Context: 4.73
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14ALevack Mine · copperGrade: 1.7Grade Unit: %Intercept: 2.42 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.7
- Grade Unit
- %
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.9
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of strong grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.70”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · nickelGrade: 0.92Grade Unit: %Intercept: 2.42 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.92
- Grade Unit
- %
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.19
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.92”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · cobaltGrade: 0.02Grade Unit: %Intercept: 2.42 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.02”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · platinumGrade: 1.29Grade Unit: g/tIntercept: 2.42 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.29
- Grade Unit
- g/t
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of moderate grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.29”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · palladiumGrade: 1.88Grade Unit: g/tIntercept: 2.42 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.88
- Grade Unit
- g/t
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of moderate grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.88”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · goldGrade: 0.08Grade Unit: g/tIntercept: 2.42 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.08”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · silverGrade: 7.19Grade Unit: g/tIntercept: 2.42 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 7.19
- Grade Unit
- g/t
- Intercept
- 2.42 m
- From
- 790.38 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:790.38-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of low grade and narrow width, but represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“7.19”
Context: 2.42
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14ALevack Mine · copperGrade: 7.87Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 7.87
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.65
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“7.87”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · nickelGrade: 0.89Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.89
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 5.42
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.89”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · cobaltGrade: 0Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.00”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · platinumGrade: 1.43Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.43
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.43”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · palladiumGrade: 1.61Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.61
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.61”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · goldGrade: 0.05Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.05”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · silverGrade: 33Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 33
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 792.5 m
- To
- 792.8 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:792.5-792.8
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of moderate grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“33.00”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14ALevack Mine · copperGrade: 0.86Grade Unit: %Intercept: 2.92 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.86
- Grade Unit
- %
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.82
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of moderate grade and narrow width, but is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.86”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · nickelGrade: 1.6Grade Unit: %Intercept: 2.92 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.6
- Grade Unit
- %
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.71
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of strong grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.60”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · cobaltGrade: 0.01Grade Unit: %Intercept: 2.92 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.01”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · platinumGrade: 0.79Grade Unit: g/tIntercept: 2.92 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.79
- Grade Unit
- g/t
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of moderate grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.79”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · palladiumGrade: 5.19Grade Unit: g/tIntercept: 2.92 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 5.19
- Grade Unit
- g/t
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of strong grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“5.19”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · goldGrade: 0.08Grade Unit: g/tIntercept: 2.92 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.08
- Grade Unit
- g/t
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.08”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · silverGrade: 4.57Grade Unit: g/tIntercept: 2.92 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 4.57
- Grade Unit
- g/t
- Intercept
- 2.92 m
- From
- 799.5 m
- To
- 802.42 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-802.42
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of low grade and narrow width, but represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“4.57”
Context: 2.92
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14ALevack Mine · copperGrade: 2.59Grade Unit: %Intercept: 0.57 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 2.59
- Grade Unit
- %
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 19.28
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“2.59”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · nickelGrade: 8.07Grade Unit: %Intercept: 0.57 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 8.07
- Grade Unit
- %
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 10.83
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“8.07”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · cobaltGrade: 0.04Grade Unit: %Intercept: 0.57 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.04”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · platinumGrade: 3.41Grade Unit: g/tIntercept: 0.57 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 3.41
- Grade Unit
- g/t
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“3.41”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · palladiumGrade: 14.36Grade Unit: g/tIntercept: 0.57 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 14.36
- Grade Unit
- g/t
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“14.36”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · goldGrade: 0.03Grade Unit: g/tIntercept: 0.57 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.03
- Grade Unit
- g/t
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.03”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
MLV-25-14ALevack Mine · silverGrade: 14Grade Unit: g/tIntercept: 0.57 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 14
- Grade Unit
- g/t
- Intercept
- 0.57 m
- From
- 799.5 m
- To
- 800.07 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- MLV-25-14A:799.5-800.07
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of low grade and very narrow width, but represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“14.00”
Context: 0.57
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 16.68Grade Unit: %Intercept: 0.37 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 16.68
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“16.68”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.07Grade Unit: %Intercept: 0.37 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 9.57
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.07”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0Grade Unit: %Intercept: 0.37 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.00”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 1.33Grade Unit: g/tIntercept: 0.37 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.33
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.33”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 2.44Grade Unit: g/tIntercept: 0.37 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 2.44
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“2.44”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 0.09Grade Unit: g/tIntercept: 0.37 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.09”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 52Grade Unit: g/tIntercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 52
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:991.85-992.22
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of strong grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“52.00”
Context: 0.37
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 13.75Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 13.75
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 18.99
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“13.75”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.49Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.49
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 10.67
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.49”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.00”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 3.29Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 3.29
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“3.29”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 13.72Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 13.72
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“13.72”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 1.56Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.56
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.56”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 40Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 40
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1005.48 m
- To
- 1005.78 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1005.48-1005.78
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of moderate grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“40.00”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 2.87Grade Unit: %Intercept: 0.36 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 2.87
- Grade Unit
- %
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.65
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“2.87”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.05Grade Unit: %Intercept: 0.36 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 3.73
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.05”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0Grade Unit: %Intercept: 0.36 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.00”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 7.98Grade Unit: g/tIntercept: 0.36 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 7.98
- Grade Unit
- g/t
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“7.98”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 5.64Grade Unit: g/tIntercept: 0.36 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 5.64
- Grade Unit
- g/t
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“5.64”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 0.81Grade Unit: g/tIntercept: 0.36 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.81
- Grade Unit
- g/t
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.81”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 40Grade Unit: g/tIntercept: 0.36 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 40
- Grade Unit
- g/t
- Intercept
- 0.36 m
- From
- 1048.48 m
- To
- 1048.84 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1048.48-1048.84
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of moderate grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“40.00”
Context: 0.36
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 3.24Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 3.24
- Grade Unit
- %
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.19
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“3.24”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.1Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.36
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.10”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0Grade Unit: %Intercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of very low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.00”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 0.7Grade Unit: g/tIntercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.7
- Grade Unit
- g/t
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.70”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 1.93Grade Unit: g/tIntercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.93
- Grade Unit
- g/t
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.93”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 0.54Grade Unit: g/tIntercept: 0.45 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.54
- Grade Unit
- g/t
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.54”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 19Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 19
- Grade Unit
- g/t
- Intercept
- 0.45 m
- From
- 1050.7 m
- To
- 1051.15 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1050.7-1051.15
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of low grade and very narrow width, but represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“19.00”
Context: 0.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 6.58Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 6.58
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 11.83
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“6.58”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.68Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.68
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 6.65
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.68”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0.01Grade Unit: %Intercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.01”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 7.03Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 7.03
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“7.03”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 8.18Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 8.18
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“8.18”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 1.31Grade Unit: g/tIntercept: 0.3 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.31
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.31”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 42Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 42
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 1056.41 m
- To
- 1056.71 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1056.41-1056.71
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of moderate grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“42.00”
Context: 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 12.77Grade Unit: %Intercept: 2.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 12.77
- Grade Unit
- %
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 26.81
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of exceptional grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“12.77”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.55Grade Unit: %Intercept: 2.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.55
- Grade Unit
- %
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 15.06
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.55”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0.01Grade Unit: %Intercept: 2.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.01”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 3.39Grade Unit: g/tIntercept: 2.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 3.39
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of strong grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“3.39”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 7.79Grade Unit: g/tIntercept: 2.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 7.79
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of exceptional grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“7.79”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 20.67Grade Unit: g/tIntercept: 2.6 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 20.67
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of exceptional grade but narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“20.67”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 87.57Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 87.57
- Grade Unit
- g/t
- Intercept
- 2.6 m
- From
- 1152.23 m
- To
- 1154.83 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1152.23-1154.83
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of moderate grade but narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“87.57”
Context: 2.60
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 29.21Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 29.21
- Grade Unit
- %
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 50.96
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of bonanza grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“29.21”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 0.92Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.92
- Grade Unit
- %
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 28.62
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.92”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0.02Grade Unit: %Intercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.02”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 7.26Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 7.26
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“7.26”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 15.84Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 15.84
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of bonanza grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“15.84”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 29.87Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 29.87
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of bonanza grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“29.87”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 190Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 190
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 1153.16 m
- To
- 1154.16 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1153.16-1154.16
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of bonanza grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“190.00”
Context: 1.00
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1Levack Mine · copperGrade: 25.53Grade Unit: %Intercept: 0.54 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 25.53
- Grade Unit
- %
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 34.79
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of bonanza grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“25.53”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · nickelGrade: 1.8Grade Unit: %Intercept: 0.54 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.8
- Grade Unit
- %
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 19.54
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“1.80”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · cobaltGrade: 0.03Grade Unit: %Intercept: 0.54 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“0.03”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · platinumGrade: 10.4Grade Unit: g/tIntercept: 0.54 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 10.4
- Grade Unit
- g/t
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of bonanza grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“10.40”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · palladiumGrade: 12.08Grade Unit: g/tIntercept: 0.54 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 12.08
- Grade Unit
- g/t
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of exceptional grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“12.08”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · goldGrade: 3.8Grade Unit: g/tIntercept: 0.54 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 3.8
- Grade Unit
- g/t
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2025-08-28T00:00:00.000Z
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of strong grade but very narrow width, and is a previously reported result, reducing its novelty. True width is not disclosed.
Positive factors
- QA/QC Disclosed
Negative factors
- Apparent Width Only
- Stale Data Re-release
Evidence · table
“3.80”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
FNX6083-W1Levack Mine · silverGrade: 169Grade Unit: g/tIntercept: 0.54 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 169
- Grade Unit
- g/t
- Intercept
- 0.54 m
- From
- 1196.6 m
- To
- 1197.14 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W1:1196.6-1197.14
- Mining Method
- underground
Location
- Location
- R2 Target
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of bonanza grade but very narrow width, and represents new assay data for a previously reported hole, adding some novelty. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
Negative factors
- Apparent Width Only
Evidence · table
“169.00”
Context: 0.54
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · copperGrade: 19.27Grade Unit: %Intercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 19.27
- Grade Unit
- %
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 25.95
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of bonanza grade but very narrow width, representing a new high-grade intersection in a step-out hole, indicating potential for extension. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“19.27”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · nickelGrade: 0.26Grade Unit: %Intercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 14.57
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of low grade and very narrow width, but represents a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“0.26”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · cobaltGrade: 0.01Grade Unit: %Intercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 25.95
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and very narrow width, but represents a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“0.01”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · platinumGrade: 8.91Grade Unit: g/tIntercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 8.91
- Grade Unit
- g/t
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 25.95
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of bonanza grade but very narrow width, representing a new high-grade intersection in a step-out hole. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“8.91”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · palladiumGrade: 15.19Grade Unit: g/tIntercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 15.19
- Grade Unit
- g/t
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 25.95
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of bonanza grade but very narrow width, representing a new high-grade intersection in a step-out hole. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“15.19”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · goldGrade: 2.02Grade Unit: g/tIntercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 2.02
- Grade Unit
- g/t
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 25.95
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This gold intercept is of strong grade but very narrow width, representing a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“2.02”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · silverGrade: 127Grade Unit: g/tIntercept: 0.51 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 127
- Grade Unit
- g/t
- Intercept
- 0.51 m
- From
- 1097.05 m
- To
- 1097.56 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1097.05-1097.56
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 25.95
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This silver intercept is of bonanza grade but very narrow width, representing a new high-grade intersection in a step-out hole. True width is not disclosed.
Positive factors
- Bonanza Intercept
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“127.00”
Context: 0.51
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · copperGrade: 1.93Grade Unit: %Intercept: 9.76 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.93
- Grade Unit
- %
- Intercept
- 9.76 m
- From
- 1106.71 m
- To
- 1116.47 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1106.71-1116.47
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 4.19
- Metal Eq. Unit
- % CuEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This copper intercept is of strong grade and moderate width, representing a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“1.93”
Context: 9.76
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · nickelGrade: 0.69Grade Unit: %Intercept: 9.76 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.69
- Grade Unit
- %
- Intercept
- 9.76 m
- From
- 1106.71 m
- To
- 1116.47 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1106.71-1116.47
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 2.35
- Metal Eq. Unit
- % NiEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This nickel intercept is of moderate grade and moderate width, representing a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“0.69”
Context: 9.76
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · cobaltGrade: 0.01Grade Unit: %Intercept: 9.76 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 9.76 m
- From
- 1106.71 m
- To
- 1116.47 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1106.71-1116.47
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This cobalt intercept is of low grade and moderate width, but represents a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“0.01”
Context: 9.76
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · platinumGrade: 1.53Grade Unit: g/tIntercept: 9.76 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.53
- Grade Unit
- g/t
- Intercept
- 9.76 m
- From
- 1106.71 m
- To
- 1116.47 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1106.71-1116.47
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This platinum intercept is of moderate grade and moderate width, representing a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“1.53”
Context: 9.76
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W2Levack Mine · palladiumGrade: 2.41Grade Unit: g/tIntercept: 9.76 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W2
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 2.41
- Grade Unit
- g/t
- Intercept
- 9.76 m
- From
- 1106.71 m
- To
- 1116.47 m
- Hole Depth
- 1235 m
- Intercept Depth
- 1097.05 m
Classification
- Deposit Type
- other
- Program
- exploration
- Sample Type
- drill
- Group ID
- FNX6083-W2:1106.71-1116.47
- Mining Method
- underground
Location
- Location
- No. 3 Footwall
- Easting
- 471667
- Northing
- 5167000
- CRS
- NAD 83 Zone 17
- EPSG
- 26917
- Elevation
- 398 m
- Azimuth
- 116 °
- Dip
- 63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: This palladium intercept is of moderate grade and moderate width, representing a new intersection in a step-out hole. True width is not disclosed.
Positive factors
- QA/QC Disclosed
- Step-Out Extension
Negative factors
- Apparent Width Only
Evidence · table
“2.41”
Context: 9.76
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · copperGrade: 0.33Grade Unit: %Intercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.33 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 5.0 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.33”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · nickelGrade: 0.8Grade Unit: %Intercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.8
- Grade Unit
- %
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.8 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.80”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · cobaltGrade: 0.03Grade Unit: %Intercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.03 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · platinumGrade: 0.2Grade Unit: g/tIntercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table: 0.2 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“0.20”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · palladiumGrade: 0.2Grade Unit: g/tIntercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table: 0.2 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“0.20”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · goldGrade: 0.02Grade Unit: g/tIntercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.02 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
MLV-25-14A*Levack Mine · silverGrade: 1.18Grade Unit: g/tIntercept: 15.29 mView all detailsHide details
Identity
- Hole ID
- MLV-25-14A*
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.18
- Grade Unit
- g/t
- Intercept
- 15.29 m
- From
- 340.26 m
- To
- 355.55 m
- Intercept Depth
- 340.26 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- MLV-25-14A*:340.26-355.55
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 1.7
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 1.18 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 18.0 g/t·m is below.
Negative factors
- 1.18 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.18”
Context: MLV-25-14A*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · copperGrade: 16.68Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- copper
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 16.68
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 16.68 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 6.2 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 16.68 % copper is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“16.68”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · nickelGrade: 0.07Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- nickel
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.07 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · cobaltGrade: 0Grade Unit: %Intercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- cobalt
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · platinumGrade: 1.33Grade Unit: g/tIntercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- platinum
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 1.33
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table: 1.33 g/t platinum. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for platinum; intercept not scored.
Evidence · table
“1.33”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · palladiumGrade: 2.44Grade Unit: g/tIntercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- palladium
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 2.44
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table: 2.44 g/t palladium. No grade band defined for this commodity, so the score is a placeholder.
Negative factors
- No grade rubric for palladium; intercept not scored.
Evidence · table
“2.44”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · goldGrade: 0.09Grade Unit: g/tIntercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- gold
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
FNX6083-W1*Levack Mine · silverGrade: 52Grade Unit: g/tIntercept: 0.37 mView all detailsHide details
Identity
- Hole ID
- FNX6083-W1*
- Project
- Levack Mine
- Commodity
- silver
- Region
- canada_on
- Reported Region
- canada_on
- Ticker
- NICU
Geometry
- Grade
- 52
- Grade Unit
- g/t
- Intercept
- 0.37 m
- From
- 991.85 m
- To
- 992.22 m
- Intercept Depth
- 991.85 m
Classification
- Deposit Type
- other
- Sample Type
- drill
- Group ID
- FNX6083-W1*:991.85-992.22
- Mining Method
- underground
QA/QC
- Laboratory
- SGS Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Metal Equivalent
- Metal Eq. Grade
- 17.03
- Metal Eq. Unit
- % Cu-Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-10-23T00:00:00.000Z
Reasoning: Expanded from assay table. 52 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 19.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“52.00”
Context: FNX6083-W1*
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.