Mithril Drills High-Grade Gold-Silver At Target 1 And Further Expands The District Scale, Copalquin, Mexico

Original announcement by tmx on

Company
Mithril Silver and Gold Limited
Ticker
MSG
Exchange
TSX
Region
Mexico
Primary commodity
Gold
Secondary commodities
Silver, Copper, Lead, Zinc
Document categories
Drill results, Resource update
Extracted
2026-09-18 11:10:21 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Mithril Silver and Gold Limited announced high-grade gold and silver drill results from its Copalquin property in Durango State, Mexico, including 0.5m at 57.65 g/t gold and 924 g/t silver. These results expand the resource potential at Target 1 ahead of an upcoming Mineral Resource Estimate update. The company also re-published its maiden JORC and NI 43-101 compliant resource estimate from 2021 for the Copalquin district.

Reasoning: The document reports new high-grade gold-silver drill results that expand the known mineralization and provide vectors for a future resource update, confirming the district's potential. However, the resource estimate detailed in the document is a re-print of a 2021 estimate, not a new one.

Positive factors

  • High-grade gold and silver intercepts reported from new drilling
  • Drilling successfully expanded the resource potential and footprint at Target 1
  • Identification of a large hydrothermal system and potential feeder zones
  • Upcoming MRE update for Target 1 is planned
  • Comprehensive QA/QC procedures disclosed and QP/CP signed off

Negative factors

  • The mineral resource estimate detailed in the announcement is a re-print of a 2021 estimate, not a new one
  • True width is not fully understood for all intercepts, particularly at La Soledad

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 933

Extracted facts

Stored fact records: 933. Some facts used in scoring do not have a stored record.

Drill Results (931)

MTH-RE25-46Copalquin · goldGrade: 0.59Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.59
Grade Unit
g/t
Intercept
1.7 m
From
59.5 m
To
61.2 m
Hole Depth
249 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-46:59.5-61.2

Location

Easting
289355
Northing
2823700
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1246.14 m
Azimuth
188 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.75
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.59”

Context: 1.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-46Copalquin · silverGrade: 11.1Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.1
Grade Unit
g/t
Intercept
1.7 m
From
59.5 m
To
61.2 m
Hole Depth
249 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-46:59.5-61.2

Location

Easting
289355
Northing
2823700
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1246.14 m
Azimuth
188 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.75
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“11.1”

Context: 1.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-46Copalquin · goldGrade: 1.37Grade Unit: g/tIntercept: 3.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.37
Grade Unit
g/t
Intercept
3.95 m
From
65.25 m
To
69.2 m
Hole Depth
249 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-46:65.25-69.2

Location

Easting
289355
Northing
2823700
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1246.14 m
Azimuth
188 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“1.37”

Context: 3.95

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-46Copalquin · silverGrade: 22.2Grade Unit: g/tIntercept: 3.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
22.2
Grade Unit
g/t
Intercept
3.95 m
From
65.25 m
To
69.2 m
Hole Depth
249 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-46:65.25-69.2

Location

Easting
289355
Northing
2823700
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1246.14 m
Azimuth
188 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“22.2”

Context: 3.95

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-47Copalquin · goldGrade: 1.18Grade Unit: g/tIntercept: 2.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.18
Grade Unit
g/t
Intercept
2.35 m
From
442.3 m
To
444.65 m
Hole Depth
516 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-47:442.3-444.65

Location

Easting
288996.3
Northing
2824042
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1188.21 m
Azimuth
210 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.52
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“1.18”

Context: 2.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-47Copalquin · silverGrade: 24.2Grade Unit: g/tIntercept: 2.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24.2
Grade Unit
g/t
Intercept
2.35 m
From
442.3 m
To
444.65 m
Hole Depth
516 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-47:442.3-444.65

Location

Easting
288996.3
Northing
2824042
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1188.21 m
Azimuth
210 °
Dip
-75 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.52
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“24.2”

Context: 2.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-52Copalquin · goldGrade: 1.11Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.11
Grade Unit
g/t
Intercept
0.5 m
From
72.7 m
To
73.2 m
Hole Depth
450 m
Intercept Depth
72.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-52:72.7-73.2

Location

Easting
289943
Northing
2824082
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1094.17 m
Azimuth
210 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“1.11”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-52Copalquin · silverGrade: 4.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.4
Grade Unit
g/t
Intercept
0.5 m
From
72.7 m
To
73.2 m
Hole Depth
450 m
Intercept Depth
72.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-52:72.7-73.2

Location

Easting
289943
Northing
2824082
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1094.17 m
Azimuth
210 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“4.4”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-52Copalquin · goldGrade: 0.39Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.39
Grade Unit
g/t
Intercept
1.5 m
From
264.5 m
To
266 m
Hole Depth
450 m
Intercept Depth
264.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-52:264.5-266

Location

Easting
289943
Northing
2824082
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1094.17 m
Azimuth
210 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.39”

Context: 1.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-52Copalquin · silverGrade: 63.6Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
63.6
Grade Unit
g/t
Intercept
1.5 m
From
264.5 m
To
266 m
Hole Depth
450 m
Intercept Depth
264.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-52:264.5-266

Location

Easting
289943
Northing
2824082
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1094.17 m
Azimuth
210 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“63.6”

Context: 1.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 2.64Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.64
Grade Unit
g/t
Intercept
0.5 m
From
44.7 m
To
45.2 m
Hole Depth
339 m
Intercept Depth
44.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:44.7-45.2

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade gold intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“2.64”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 42.3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
42.3
Grade Unit
g/t
Intercept
0.5 m
From
44.7 m
To
45.2 m
Hole Depth
339 m
Intercept Depth
44.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:44.7-45.2

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade silver intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“42.3”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 1.68Grade Unit: g/tIntercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.68
Grade Unit
g/t
Intercept
3.05 m
From
52 m
To
55.05 m
Hole Depth
339 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:52-55.05

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade gold intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“1.68”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 107Grade Unit: g/tIntercept: 3.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
107
Grade Unit
g/t
Intercept
3.05 m
From
52 m
To
55.05 m
Hole Depth
339 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:52-55.05

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade silver intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“107”

Context: 3.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 9.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.6
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Hole Depth
339 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:52-52.5

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade gold intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade gold intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“9.60”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 612Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
612
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Hole Depth
339 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:52-52.5

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade silver intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade silver intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“612”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 2.29Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.29
Grade Unit
g/t
Intercept
2.8 m
From
65.25 m
To
68.05 m
Hole Depth
339 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:65.25-68.05

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade gold intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“2.29”

Context: 2.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 60.3Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
60.3
Grade Unit
g/t
Intercept
2.8 m
From
65.25 m
To
68.05 m
Hole Depth
339 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:65.25-68.05

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade silver intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“60.3”

Context: 2.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 10.55Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.55
Grade Unit
g/t
Intercept
0.5 m
From
67.55 m
To
68.05 m
Hole Depth
339 m
Intercept Depth
67.55 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:67.55-68.05

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade gold intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade gold intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“10.55”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 298Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
298
Grade Unit
g/t
Intercept
0.5 m
From
67.55 m
To
68.05 m
Hole Depth
339 m
Intercept Depth
67.55 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:67.55-68.05

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade silver intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade silver intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“298”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 2.18Grade Unit: g/tIntercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.18
Grade Unit
g/t
Intercept
4.4 m
From
77.2 m
To
81.6 m
Hole Depth
339 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:77.2-81.6

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade gold intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“2.18”

Context: 4.40

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 14.6Grade Unit: g/tIntercept: 4.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14.6
Grade Unit
g/t
Intercept
4.4 m
From
77.2 m
To
81.6 m
Hole Depth
339 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:77.2-81.6

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade silver intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“14.6”

Context: 4.40

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 15.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.5
Grade Unit
g/t
Intercept
0.5 m
From
81.1 m
To
81.6 m
Hole Depth
339 m
Intercept Depth
81.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:81.1-81.6

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.44
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade gold intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade gold intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“15.50”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 66.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
66.1
Grade Unit
g/t
Intercept
0.5 m
From
81.1 m
To
81.6 m
Hole Depth
339 m
Intercept Depth
81.1 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:81.1-81.6

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.44
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade silver intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade silver intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“66.1”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 0.44Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.44
Grade Unit
g/t
Intercept
1.3 m
From
91.7 m
To
93 m
Hole Depth
339 m
Intercept Depth
91.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:91.7-93

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.45
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.44”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 0.7Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.7
Grade Unit
g/t
Intercept
1.3 m
From
91.7 m
To
93 m
Hole Depth
339 m
Intercept Depth
91.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:91.7-93

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.45
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.7”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · goldGrade: 1.07Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.07
Grade Unit
g/t
Intercept
0.5 m
From
226 m
To
226.5 m
Hole Depth
339 m
Intercept Depth
226 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:226-226.5

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“1.07”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-LS25-53Copalquin · silverGrade: 2.7Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
0.5 m
From
226 m
To
226.5 m
Hole Depth
339 m
Intercept Depth
226 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-LS25-53:226-226.5

Location

Easting
289601
Northing
2824056
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1141.2 m
Azimuth
180 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“2.7”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 0.27Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.27
Grade Unit
g/t
Intercept
2.8 m
From
5.5 m
To
8.3 m
Hole Depth
417 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:5.5-8.3

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.56
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.27”

Context: 2.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 19.7Grade Unit: g/tIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19.7
Grade Unit
g/t
Intercept
2.8 m
From
5.5 m
To
8.3 m
Hole Depth
417 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:5.5-8.3

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.56
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“19.7”

Context: 2.80

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 0.6Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
0.65 m
From
12 m
To
12.65 m
Hole Depth
417 m
Intercept Depth
12 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:12-12.65

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.87
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.60”

Context: 0.65

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 19.1Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19.1
Grade Unit
g/t
Intercept
0.65 m
From
12 m
To
12.65 m
Hole Depth
417 m
Intercept Depth
12 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:12-12.65

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.87
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“19.1”

Context: 0.65

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 0.31Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.31
Grade Unit
g/t
Intercept
1.15 m
From
18.85 m
To
20 m
Hole Depth
417 m
Intercept Depth
18.85 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:18.85-20

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.47
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.31”

Context: 1.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 11Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
1.15 m
From
18.85 m
To
20 m
Hole Depth
417 m
Intercept Depth
18.85 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:18.85-20

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.47
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“11.0”

Context: 1.15

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 2.11Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.11
Grade Unit
g/t
Intercept
1.55 m
From
24.65 m
To
26.2 m
Hole Depth
417 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:24.65-26.2

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade gold intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“2.11”

Context: 1.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 5.5Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
1.55 m
From
24.65 m
To
26.2 m
Hole Depth
417 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:24.65-26.2

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade silver intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“5.50”

Context: 1.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 0.524Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.524
Grade Unit
g/t
Intercept
0.9 m
From
28.7 m
To
29.6 m
Hole Depth
417 m
Intercept Depth
28.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:28.7-29.6

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.524”

Context: 0.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 23.1Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23.1
Grade Unit
g/t
Intercept
0.9 m
From
28.7 m
To
29.6 m
Hole Depth
417 m
Intercept Depth
28.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:28.7-29.6

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“23.1”

Context: 0.90

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 0.3Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
2.6 m
From
32.25 m
To
34.85 m
Hole Depth
417 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:32.25-34.85

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.30”

Context: 2.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 2.4Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.4
Grade Unit
g/t
Intercept
2.6 m
From
32.25 m
To
34.85 m
Hole Depth
417 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:32.25-34.85

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“2.40”

Context: 2.60

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 0.72Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.72
Grade Unit
g/t
Intercept
1.3 m
From
133.7 m
To
135 m
Hole Depth
417 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:133.7-135

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“0.72”

Context: 1.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 54.7Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
54.7
Grade Unit
g/t
Intercept
1.3 m
From
133.7 m
To
135 m
Hole Depth
417 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:133.7-135

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“54.7”

Context: 1.30

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 21.94Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21.94
Grade Unit
g/t
Intercept
1.35 m
From
142.75 m
To
144.1 m
Hole Depth
417 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:142.75-144.1

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
27.04
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade gold intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade gold intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“21.94”

Context: 1.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 357Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
357
Grade Unit
g/t
Intercept
1.35 m
From
142.75 m
To
144.1 m
Hole Depth
417 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:142.75-144.1

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
27.04
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Bonanza grade silver intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Bonanza grade silver intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“357”

Context: 1.35

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · goldGrade: 57.65Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
57.65
Grade Unit
g/t
Intercept
0.5 m
From
143.6 m
To
144.1 m
Hole Depth
417 m
Intercept Depth
143.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:143.6-144.1

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
70.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Exceptional bonanza grade gold intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Exceptional bonanza grade gold intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“57.65”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-54Copalquin · silverGrade: 924Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
924
Grade Unit
g/t
Intercept
0.5 m
From
143.6 m
To
144.1 m
Hole Depth
417 m
Intercept Depth
143.6 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-54:143.6-144.1

Location

Easting
289519
Northing
2823757
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1192.72 m
Azimuth
165 °
Dip
-55 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
70.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Exceptional bonanza grade silver intercept from drilling at Target 1, contributing significantly to the resource expansion efforts.

Positive factors

  • Exceptional bonanza grade silver intercept, significantly above deposit-type norm
  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“924”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-56Copalquin · goldGrade: 0.78Grade Unit: g/tIntercept: 5.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.78
Grade Unit
g/t
Intercept
5.45 m
From
441.75 m
To
447.2 m
Hole Depth
516 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-56:441.75-447.2

Location

Easting
289004
Northing
2824047
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1189.1 m
Azimuth
210 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“0.78”

Context: 5.45

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-56Copalquin · silverGrade: 35.9Grade Unit: g/tIntercept: 5.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
35.9
Grade Unit
g/t
Intercept
5.45 m
From
441.75 m
To
447.2 m
Hole Depth
516 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-56:441.75-447.2

Location

Easting
289004
Northing
2824047
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1189.1 m
Azimuth
210 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“35.9”

Context: 5.45

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-56Copalquin · goldGrade: 1.08Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.08
Grade Unit
g/t
Intercept
0.95 m
From
441.75 m
To
442.7 m
Hole Depth
516 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-56:441.75-442.7

Location

Easting
289004
Northing
2824047
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1189.1 m
Azimuth
210 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Negative factors

  • True width not fully understood for this hole

Evidence · table

“1.08”

Context: 0.95

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-56Copalquin · silverGrade: 39.5Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39.5
Grade Unit
g/t
Intercept
0.95 m
From
441.75 m
To
442.7 m
Hole Depth
516 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-56:441.75-442.7

Location

Easting
289004
Northing
2824047
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1189.1 m
Azimuth
210 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“39.5”

Context: 0.95

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-56Copalquin · goldGrade: 1.26Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.26
Grade Unit
g/t
Intercept
2.5 m
From
444.7 m
To
447.2 m
Hole Depth
516 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-56:444.7-447.2

Location

Easting
289004
Northing
2824047
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1189.1 m
Azimuth
210 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“1.26”

Context: 2.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-56Copalquin · silverGrade: 62.1Grade Unit: g/tIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
62.1
Grade Unit
g/t
Intercept
2.5 m
From
444.7 m
To
447.2 m
Hole Depth
516 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-56:444.7-447.2

Location

Easting
289004
Northing
2824047
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1189.1 m
Azimuth
210 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from deep drilling at Target 1, contributing to the resource expansion efforts and providing vectors for future exploration.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed
  • Deepest intercept in this area to date, providing vectors for continued expansion

Negative factors

  • True width not fully understood for this hole

Evidence · table

“62.1”

Context: 2.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-57Copalquin · goldGrade: 1.43Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.43
Grade Unit
g/t
Intercept
0.5 m
From
189.15 m
To
189.65 m
Hole Depth
351 m
Intercept Depth
189.15 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-57:189.15-189.65

Location

Easting
288757
Northing
2823827
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1190.94 m
Azimuth
210 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade gold intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“1.43”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-57Copalquin · silverGrade: 128Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
128
Grade Unit
g/t
Intercept
0.5 m
From
189.15 m
To
189.65 m
Hole Depth
351 m
Intercept Depth
189.15 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-57:189.15-189.65

Location

Easting
288757
Northing
2823827
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1190.94 m
Azimuth
210 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New high-grade silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New high-grade silver intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“128”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-58Copalquin · goldGrade: 1.09Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.09
Grade Unit
g/t
Intercept
0.5 m
From
165.85 m
To
166.35 m
Hole Depth
300 m
Intercept Depth
165.85 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-58:165.85-166.35

Location

Easting
288757
Northing
2823827
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1190.94 m
Azimuth
185 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New gold intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“1.09”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-58Copalquin · silverGrade: 82.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
82.2
Grade Unit
g/t
Intercept
0.5 m
From
165.85 m
To
166.35 m
Hole Depth
300 m
Intercept Depth
165.85 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
MTH-RE25-58:165.85-166.35

Location

Easting
288757
Northing
2823827
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
1190.94 m
Azimuth
185 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t AuEq
Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: New silver intercept from drilling at Target 1, contributing to the resource expansion efforts.

Positive factors

  • New drill intercept contributes to resource expansion
  • QA/QC procedures and metal equivalent assumptions are disclosed

Evidence · table

“82.2”

Context: 0.50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Compositing Transparentpositive

Cut-off grade and internal dilution rules are clearly stated for reported intervals.

Why it applies: cutoff_grade and internal dilution are both stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

MTH-RE25-46Copalquin · goldGrade: 0.451Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.451
Grade Unit
g/t
Intercept
1.1 m
From
59.5 m
To
60.6 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:59.5-60.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.451 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.451”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 10.8Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.8
Grade Unit
g/t
Intercept
1.1 m
From
59.5 m
To
60.6 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:59.5-60.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.9 g/t·m is below.

Negative factors

  • 10.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.8”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 55Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
55
Grade Unit
g/t
Intercept
1.1 m
From
59.5 m
To
60.6 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:59.5-60.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 55 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“55”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 7Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
1.1 m
From
59.5 m
To
60.6 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:59.5-60.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 89Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
89
Grade Unit
g/t
Intercept
1.1 m
From
59.5 m
To
60.6 m
Intercept Depth
59.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:59.5-60.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 89 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“89”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 0.858Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.858
Grade Unit
g/t
Intercept
0.6 m
From
60.6 m
To
61.2 m
Intercept Depth
60.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:60.6-61.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.03
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.858 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.858”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 11.7Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.7
Grade Unit
g/t
Intercept
0.6 m
From
60.6 m
To
61.2 m
Intercept Depth
60.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:60.6-61.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.03
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 11.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.0 g/t·m is below.

Negative factors

  • 11.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“11.7”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 56Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
56
Grade Unit
g/t
Intercept
0.6 m
From
60.6 m
To
61.2 m
Intercept Depth
60.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:60.6-61.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.03
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 56 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“56”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 7Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.6 m
From
60.6 m
To
61.2 m
Intercept Depth
60.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:60.6-61.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.03
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 90Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
90
Grade Unit
g/t
Intercept
0.6 m
From
60.6 m
To
61.2 m
Intercept Depth
60.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:60.6-61.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.03
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 90 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“90”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 0.073Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.073
Grade Unit
g/t
Intercept
0.7 m
From
64.55 m
To
65.25 m
Intercept Depth
64.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:64.55-65.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.073 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.073 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.073”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 5.6Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.6
Grade Unit
g/t
Intercept
0.7 m
From
64.55 m
To
65.25 m
Intercept Depth
64.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:64.55-65.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.9 g/t·m is below.

Negative factors

  • 5.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.6”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 47Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
47
Grade Unit
g/t
Intercept
0.7 m
From
64.55 m
To
65.25 m
Intercept Depth
64.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:64.55-65.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 47 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“47”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 75Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
75
Grade Unit
g/t
Intercept
0.7 m
From
64.55 m
To
65.25 m
Intercept Depth
64.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:64.55-65.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 75 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“75”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 122Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
122
Grade Unit
g/t
Intercept
0.7 m
From
64.55 m
To
65.25 m
Intercept Depth
64.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:64.55-65.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 122 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“122”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 1.925Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.925
Grade Unit
g/t
Intercept
0.55 m
From
65.25 m
To
65.8 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.25-65.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.59
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.925 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.1 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.925”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 46.5Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
46.5
Grade Unit
g/t
Intercept
0.55 m
From
65.25 m
To
65.8 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.25-65.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.59
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 46.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 25.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“46.5”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 46Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
46
Grade Unit
g/t
Intercept
0.55 m
From
65.25 m
To
65.8 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.25-65.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.59
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 46 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“46”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 25Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
0.55 m
From
65.25 m
To
65.8 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.25-65.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.59
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 84Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
84
Grade Unit
g/t
Intercept
0.55 m
From
65.25 m
To
65.8 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.25-65.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.59
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 84 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“84”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 0.45Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.45
Grade Unit
g/t
Intercept
0.65 m
From
65.8 m
To
66.45 m
Intercept Depth
65.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.8-66.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.45 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.45”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 8.8Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.8
Grade Unit
g/t
Intercept
0.65 m
From
65.8 m
To
66.45 m
Intercept Depth
65.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.8-66.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 8.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.7 g/t·m is below.

Negative factors

  • 8.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.8”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 34Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
34
Grade Unit
g/t
Intercept
0.65 m
From
65.8 m
To
66.45 m
Intercept Depth
65.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.8-66.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 34 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“34”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 9Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
0.65 m
From
65.8 m
To
66.45 m
Intercept Depth
65.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.8-66.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 49Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
49
Grade Unit
g/t
Intercept
0.65 m
From
65.8 m
To
66.45 m
Intercept Depth
65.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:65.8-66.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.58
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 49 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“49”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 3.65Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.65
Grade Unit
g/t
Intercept
0.55 m
From
66.45 m
To
67 m
Intercept Depth
66.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:66.45-67

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.65 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.0 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 3.65 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.65”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 45.3Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
45.3
Grade Unit
g/t
Intercept
0.55 m
From
66.45 m
To
67 m
Intercept Depth
66.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:66.45-67

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 45.3 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 24.9 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“45.3”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 44Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
44
Grade Unit
g/t
Intercept
0.55 m
From
66.45 m
To
67 m
Intercept Depth
66.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:66.45-67

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 44 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“44”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
0.55 m
From
66.45 m
To
67 m
Intercept Depth
66.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:66.45-67

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 65Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
65
Grade Unit
g/t
Intercept
0.55 m
From
66.45 m
To
67 m
Intercept Depth
66.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:66.45-67

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 65 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“65”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 1.31Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.31
Grade Unit
g/t
Intercept
0.8 m
From
67 m
To
67.8 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67-67.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.31 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.31”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 20.8Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20.8
Grade Unit
g/t
Intercept
0.8 m
From
67 m
To
67.8 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67-67.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 20.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.6 g/t·m is below.

Negative factors

  • 20.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“20.8”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 34Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
34
Grade Unit
g/t
Intercept
0.8 m
From
67 m
To
67.8 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67-67.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 34 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“34”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 31Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
0.8 m
From
67 m
To
67.8 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67-67.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 108Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
108
Grade Unit
g/t
Intercept
0.8 m
From
67 m
To
67.8 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67-67.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 108 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“108”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 1.285Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.285
Grade Unit
g/t
Intercept
0.6 m
From
67.8 m
To
68.4 m
Intercept Depth
67.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67.8-68.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.285 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.285”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 16.9Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16.9
Grade Unit
g/t
Intercept
0.6 m
From
67.8 m
To
68.4 m
Intercept Depth
67.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67.8-68.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 16.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 10.1 g/t·m is below.

Negative factors

  • 16.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“16.9”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 32Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
32
Grade Unit
g/t
Intercept
0.6 m
From
67.8 m
To
68.4 m
Intercept Depth
67.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67.8-68.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 32 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“32”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.6 m
From
67.8 m
To
68.4 m
Intercept Depth
67.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67.8-68.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 77Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
77
Grade Unit
g/t
Intercept
0.6 m
From
67.8 m
To
68.4 m
Intercept Depth
67.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:67.8-68.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 77 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“77”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · goldGrade: 0.313Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.313
Grade Unit
g/t
Intercept
0.8 m
From
68.4 m
To
69.2 m
Intercept Depth
68.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:68.4-69.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.313 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.313”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · silverGrade: 6Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
0.8 m
From
68.4 m
To
69.2 m
Intercept Depth
68.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:68.4-69.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.8 g/t·m is below.

Negative factors

  • 6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · copperGrade: 27Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.8 m
From
68.4 m
To
69.2 m
Intercept Depth
68.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:68.4-69.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · leadGrade: 17Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
17
Grade Unit
g/t
Intercept
0.8 m
From
68.4 m
To
69.2 m
Intercept Depth
68.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:68.4-69.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 17 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“17”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-46Copalquin · zincGrade: 77Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-46
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
77
Grade Unit
g/t
Intercept
0.8 m
From
68.4 m
To
69.2 m
Intercept Depth
68.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-46:68.4-69.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.4
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 77 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“77”

Context: MTH-RE25-46

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.08Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.08
Grade Unit
g/t
Intercept
0.7 m
From
436 m
To
436.7 m
Intercept Depth
436 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436-436.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.08 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.08”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 10.4Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.4
Grade Unit
g/t
Intercept
0.7 m
From
436 m
To
436.7 m
Intercept Depth
436 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436-436.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.3 g/t·m is below.

Negative factors

  • 10.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.4”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 60Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
60
Grade Unit
g/t
Intercept
0.7 m
From
436 m
To
436.7 m
Intercept Depth
436 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436-436.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 60 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“60”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 73Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
73
Grade Unit
g/t
Intercept
0.7 m
From
436 m
To
436.7 m
Intercept Depth
436 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436-436.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 73 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“73”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 305Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
305
Grade Unit
g/t
Intercept
0.7 m
From
436 m
To
436.7 m
Intercept Depth
436 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436-436.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 305 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“305”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.192Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.192
Grade Unit
g/t
Intercept
1.3 m
From
436.7 m
To
438 m
Intercept Depth
436.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436.7-438

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.63
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.192 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.192 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.192”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 30.8Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
30.8
Grade Unit
g/t
Intercept
1.3 m
From
436.7 m
To
438 m
Intercept Depth
436.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436.7-438

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.63
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 30.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 40.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“30.8”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 26Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
1.3 m
From
436.7 m
To
438 m
Intercept Depth
436.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436.7-438

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.63
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 78Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
78
Grade Unit
g/t
Intercept
1.3 m
From
436.7 m
To
438 m
Intercept Depth
436.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436.7-438

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.63
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 78 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“78”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 139Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
139
Grade Unit
g/t
Intercept
1.3 m
From
436.7 m
To
438 m
Intercept Depth
436.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:436.7-438

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.63
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 139 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“139”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.351Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.351
Grade Unit
g/t
Intercept
1 m
From
440 m
To
441 m
Intercept Depth
440 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:440-441

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.351 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.351”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 32.2Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
32.2
Grade Unit
g/t
Intercept
1 m
From
440 m
To
441 m
Intercept Depth
440 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:440-441

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 32.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 32.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“32.2”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 98Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
98
Grade Unit
g/t
Intercept
1 m
From
440 m
To
441 m
Intercept Depth
440 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:440-441

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 98 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“98”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 279Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
279
Grade Unit
g/t
Intercept
1 m
From
440 m
To
441 m
Intercept Depth
440 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:440-441

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 279 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“279”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 343Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
343
Grade Unit
g/t
Intercept
1 m
From
440 m
To
441 m
Intercept Depth
440 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:440-441

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 343 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“343”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.232Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.232
Grade Unit
g/t
Intercept
0.6 m
From
441 m
To
441.6 m
Intercept Depth
441 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441-441.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.232 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.232 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.232”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 5.9Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.9
Grade Unit
g/t
Intercept
0.6 m
From
441 m
To
441.6 m
Intercept Depth
441 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441-441.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.5 g/t·m is below.

Negative factors

  • 5.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.9”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 39Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39
Grade Unit
g/t
Intercept
0.6 m
From
441 m
To
441.6 m
Intercept Depth
441 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441-441.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 39 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“39”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 101Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
101
Grade Unit
g/t
Intercept
0.6 m
From
441 m
To
441.6 m
Intercept Depth
441 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441-441.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 101 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“101”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 112Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
112
Grade Unit
g/t
Intercept
0.6 m
From
441 m
To
441.6 m
Intercept Depth
441 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441-441.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 112 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“112”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.378Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.378
Grade Unit
g/t
Intercept
0.7 m
From
441.6 m
To
442.3 m
Intercept Depth
441.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441.6-442.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.378 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.378”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 7.3Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.3
Grade Unit
g/t
Intercept
0.7 m
From
441.6 m
To
442.3 m
Intercept Depth
441.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441.6-442.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.1 g/t·m is below.

Negative factors

  • 7.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.3”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 124Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
124
Grade Unit
g/t
Intercept
0.7 m
From
441.6 m
To
442.3 m
Intercept Depth
441.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441.6-442.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 124 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“124”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 696Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
696
Grade Unit
g/t
Intercept
0.7 m
From
441.6 m
To
442.3 m
Intercept Depth
441.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441.6-442.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 696 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“696”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 700Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
700
Grade Unit
g/t
Intercept
0.7 m
From
441.6 m
To
442.3 m
Intercept Depth
441.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:441.6-442.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 700 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“700”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 1.605Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.605
Grade Unit
g/t
Intercept
0.6 m
From
442.3 m
To
442.9 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.3-442.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.605 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.605”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 57.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
57.4
Grade Unit
g/t
Intercept
0.6 m
From
442.3 m
To
442.9 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.3-442.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 57.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 34.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“57.4”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 150Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
150
Grade Unit
g/t
Intercept
0.6 m
From
442.3 m
To
442.9 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.3-442.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 150 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“150”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 1005Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1005
Grade Unit
g/t
Intercept
0.6 m
From
442.3 m
To
442.9 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.3-442.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1005 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“1005”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 2260Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2260
Grade Unit
g/t
Intercept
0.6 m
From
442.3 m
To
442.9 m
Intercept Depth
442.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.3-442.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 2260 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“2260”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.836Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.836
Grade Unit
g/t
Intercept
0.6 m
From
442.9 m
To
443.5 m
Intercept Depth
442.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.9-443.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.836 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.836”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 14.8Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14.8
Grade Unit
g/t
Intercept
0.6 m
From
442.9 m
To
443.5 m
Intercept Depth
442.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.9-443.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 14.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.9 g/t·m is below.

Negative factors

  • 14.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.8”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 241Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
241
Grade Unit
g/t
Intercept
0.6 m
From
442.9 m
To
443.5 m
Intercept Depth
442.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.9-443.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 241 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“241”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 1050Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1050
Grade Unit
g/t
Intercept
0.6 m
From
442.9 m
To
443.5 m
Intercept Depth
442.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.9-443.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1050 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“1050”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 3380Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3380
Grade Unit
g/t
Intercept
0.6 m
From
442.9 m
To
443.5 m
Intercept Depth
442.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:442.9-443.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.05
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3380 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“3380”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 0.576Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.576
Grade Unit
g/t
Intercept
0.5 m
From
443.5 m
To
444 m
Intercept Depth
443.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:443.5-444

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.576 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.576”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 10.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.2
Grade Unit
g/t
Intercept
0.5 m
From
443.5 m
To
444 m
Intercept Depth
443.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:443.5-444

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.1 g/t·m is below.

Negative factors

  • 10.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.2”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 228Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
228
Grade Unit
g/t
Intercept
0.5 m
From
443.5 m
To
444 m
Intercept Depth
443.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:443.5-444

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 228 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“228”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 1060Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1060
Grade Unit
g/t
Intercept
0.5 m
From
443.5 m
To
444 m
Intercept Depth
443.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:443.5-444

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1060 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“1060”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 4430Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4430
Grade Unit
g/t
Intercept
0.5 m
From
443.5 m
To
444 m
Intercept Depth
443.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:443.5-444

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4430 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“4430”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · goldGrade: 1.555Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.555
Grade Unit
g/t
Intercept
0.65 m
From
444 m
To
444.65 m
Intercept Depth
444 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:444-444.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.555 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.555”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · silverGrade: 12.9Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12.9
Grade Unit
g/t
Intercept
0.65 m
From
444 m
To
444.65 m
Intercept Depth
444 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:444-444.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 12.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 12.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12.9”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · copperGrade: 297Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
297
Grade Unit
g/t
Intercept
0.65 m
From
444 m
To
444.65 m
Intercept Depth
444 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:444-444.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 297 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“297”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · leadGrade: 282Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
282
Grade Unit
g/t
Intercept
0.65 m
From
444 m
To
444.65 m
Intercept Depth
444 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:444-444.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 282 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“282”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-47Copalquin · zincGrade: 1585Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-47
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1585
Grade Unit
g/t
Intercept
0.65 m
From
444 m
To
444.65 m
Intercept Depth
444 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-47:444-444.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1585 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“1585”

Context: MTH-RE25-47

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · goldGrade: 0.042Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.042
Grade Unit
g/t
Intercept
2 m
From
341 m
To
343 m
Intercept Depth
341 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:341-343

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.042 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.042 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.042”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · silverGrade: 5.5Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
2 m
From
341 m
To
343 m
Intercept Depth
341 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:341-343

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.0 g/t·m is below.

Negative factors

  • 5.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.5”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · copperGrade: 390Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
390
Grade Unit
g/t
Intercept
2 m
From
341 m
To
343 m
Intercept Depth
341 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:341-343

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 390 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“390”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · leadGrade: 244Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
244
Grade Unit
g/t
Intercept
2 m
From
341 m
To
343 m
Intercept Depth
341 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:341-343

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 244 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“244”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · zincGrade: 232Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
232
Grade Unit
g/t
Intercept
2 m
From
341 m
To
343 m
Intercept Depth
341 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:341-343

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 232 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“232”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · goldGrade: 0.165Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.165
Grade Unit
g/t
Intercept
1.2 m
From
345.8 m
To
347 m
Intercept Depth
345.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:345.8-347

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.165 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.165 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.165”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · silverGrade: 1.4Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
1.2 m
From
345.8 m
To
347 m
Intercept Depth
345.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:345.8-347

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.7 g/t·m is below.

Negative factors

  • 1.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.4”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · copperGrade: 39Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39
Grade Unit
g/t
Intercept
1.2 m
From
345.8 m
To
347 m
Intercept Depth
345.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:345.8-347

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 39 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“39”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · leadGrade: 44Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
44
Grade Unit
g/t
Intercept
1.2 m
From
345.8 m
To
347 m
Intercept Depth
345.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:345.8-347

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 44 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“44”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-48Copalquin · zincGrade: 82Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-48
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
82
Grade Unit
g/t
Intercept
1.2 m
From
345.8 m
To
347 m
Intercept Depth
345.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-48:345.8-347

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 82 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“82”

Context: MTH-RE25-48

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.63Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.63
Grade Unit
g/t
Intercept
0.9 m
From
101.05 m
To
101.95 m
Intercept Depth
101.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:101.05-101.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.63 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.63”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 18.6Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18.6
Grade Unit
g/t
Intercept
0.9 m
From
101.05 m
To
101.95 m
Intercept Depth
101.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:101.05-101.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 18.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.7 g/t·m is below.

Negative factors

  • 18.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“18.6”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
0.9 m
From
101.05 m
To
101.95 m
Intercept Depth
101.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:101.05-101.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 365Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
365
Grade Unit
g/t
Intercept
0.9 m
From
101.05 m
To
101.95 m
Intercept Depth
101.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:101.05-101.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 365 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“365”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 18Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18
Grade Unit
g/t
Intercept
0.9 m
From
101.05 m
To
101.95 m
Intercept Depth
101.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:101.05-101.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.9
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 18 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“18”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.067Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.067
Grade Unit
g/t
Intercept
0.65 m
From
163 m
To
163.65 m
Intercept Depth
163 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:163-163.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.067 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.067 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.067”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 3.2Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.2
Grade Unit
g/t
Intercept
0.65 m
From
163 m
To
163.65 m
Intercept Depth
163 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:163-163.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.1 g/t·m is below.

Negative factors

  • 3.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.2”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 7Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.65 m
From
163 m
To
163.65 m
Intercept Depth
163 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:163-163.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 6Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
0.65 m
From
163 m
To
163.65 m
Intercept Depth
163 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:163-163.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 6 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“6”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 12Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.65 m
From
163 m
To
163.65 m
Intercept Depth
163 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:163-163.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.704Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.704
Grade Unit
g/t
Intercept
0.5 m
From
178.4 m
To
178.9 m
Intercept Depth
178.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.4-178.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.704 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.704”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 1.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
0.5 m
From
178.4 m
To
178.9 m
Intercept Depth
178.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.4-178.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 1.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.4”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 35Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
35
Grade Unit
g/t
Intercept
0.5 m
From
178.4 m
To
178.9 m
Intercept Depth
178.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.4-178.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 35 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“35”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 698Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
698
Grade Unit
g/t
Intercept
0.5 m
From
178.4 m
To
178.9 m
Intercept Depth
178.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.4-178.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 698 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“698”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 1190Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1190
Grade Unit
g/t
Intercept
0.5 m
From
178.4 m
To
178.9 m
Intercept Depth
178.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.4-178.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1190 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“1190”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.379Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.379
Grade Unit
g/t
Intercept
0.6 m
From
178.9 m
To
179.5 m
Intercept Depth
178.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.9-179.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.379 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.379”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 1.9Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
0.6 m
From
178.9 m
To
179.5 m
Intercept Depth
178.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.9-179.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.1 g/t·m is below.

Negative factors

  • 1.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.9”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 13Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
0.6 m
From
178.9 m
To
179.5 m
Intercept Depth
178.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.9-179.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 66Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
66
Grade Unit
g/t
Intercept
0.6 m
From
178.9 m
To
179.5 m
Intercept Depth
178.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.9-179.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 66 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“66”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 73Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
73
Grade Unit
g/t
Intercept
0.6 m
From
178.9 m
To
179.5 m
Intercept Depth
178.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:178.9-179.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 73 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“73”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.143Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.143
Grade Unit
g/t
Intercept
0.5 m
From
179.5 m
To
180 m
Intercept Depth
179.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:179.5-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.143 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.143 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.143”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 2.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
0.5 m
From
179.5 m
To
180 m
Intercept Depth
179.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:179.5-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.4 g/t·m is below.

Negative factors

  • 2.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.9”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 57Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
57
Grade Unit
g/t
Intercept
0.5 m
From
179.5 m
To
180 m
Intercept Depth
179.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:179.5-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 57 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“57”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 457Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
457
Grade Unit
g/t
Intercept
0.5 m
From
179.5 m
To
180 m
Intercept Depth
179.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:179.5-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 457 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“457”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 1745Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1745
Grade Unit
g/t
Intercept
0.5 m
From
179.5 m
To
180 m
Intercept Depth
179.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:179.5-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1745 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“1745”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.203Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.203
Grade Unit
g/t
Intercept
0.5 m
From
180 m
To
180.5 m
Intercept Depth
180 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180-180.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.203 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.203 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.203”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 3.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.6
Grade Unit
g/t
Intercept
0.5 m
From
180 m
To
180.5 m
Intercept Depth
180 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180-180.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.8 g/t·m is below.

Negative factors

  • 3.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.6”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 168Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
168
Grade Unit
g/t
Intercept
0.5 m
From
180 m
To
180.5 m
Intercept Depth
180 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180-180.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 168 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“168”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 1515Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1515
Grade Unit
g/t
Intercept
0.5 m
From
180 m
To
180.5 m
Intercept Depth
180 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180-180.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1515 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“1515”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 439Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
439
Grade Unit
g/t
Intercept
0.5 m
From
180 m
To
180.5 m
Intercept Depth
180 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180-180.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 439 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“439”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.475Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.475
Grade Unit
g/t
Intercept
0.75 m
From
180.5 m
To
181.25 m
Intercept Depth
180.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180.5-181.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.475 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.475”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 4Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.75 m
From
180.5 m
To
181.25 m
Intercept Depth
180.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180.5-181.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.0 g/t·m is below.

Negative factors

  • 4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 100Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
100
Grade Unit
g/t
Intercept
0.75 m
From
180.5 m
To
181.25 m
Intercept Depth
180.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180.5-181.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 100 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“100”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 648Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
648
Grade Unit
g/t
Intercept
0.75 m
From
180.5 m
To
181.25 m
Intercept Depth
180.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180.5-181.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 648 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“648”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 725Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
725
Grade Unit
g/t
Intercept
0.75 m
From
180.5 m
To
181.25 m
Intercept Depth
180.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:180.5-181.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.53
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 725 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“725”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.817Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.817
Grade Unit
g/t
Intercept
0.95 m
From
182.75 m
To
183.7 m
Intercept Depth
182.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:182.75-183.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.86
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.817 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.817”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 3.2Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.2
Grade Unit
g/t
Intercept
0.95 m
From
182.75 m
To
183.7 m
Intercept Depth
182.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:182.75-183.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.86
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.0 g/t·m is below.

Negative factors

  • 3.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.2”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
0.95 m
From
182.75 m
To
183.7 m
Intercept Depth
182.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:182.75-183.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.86
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 11Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
0.95 m
From
182.75 m
To
183.7 m
Intercept Depth
182.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:182.75-183.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.86
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 11 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“11”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 55Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
55
Grade Unit
g/t
Intercept
0.95 m
From
182.75 m
To
183.7 m
Intercept Depth
182.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:182.75-183.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.86
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 55 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“55”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · goldGrade: 0.091Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.091
Grade Unit
g/t
Intercept
0.55 m
From
191.45 m
To
192 m
Intercept Depth
191.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:191.45-192

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.091 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.091 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.091”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · silverGrade: 2Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
0.55 m
From
191.45 m
To
192 m
Intercept Depth
191.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:191.45-192

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.1 g/t·m is below.

Negative factors

  • 2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
0.55 m
From
191.45 m
To
192 m
Intercept Depth
191.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:191.45-192

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · leadGrade: 52Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
52
Grade Unit
g/t
Intercept
0.55 m
From
191.45 m
To
192 m
Intercept Depth
191.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:191.45-192

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 52 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“52”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-49Copalquin · zincGrade: 96Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-49
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
96
Grade Unit
g/t
Intercept
0.55 m
From
191.45 m
To
192 m
Intercept Depth
191.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-49:191.45-192

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 96 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“96”

Context: MTH-LS25-49

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · goldGrade: 0.091Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.091
Grade Unit
g/t
Intercept
0.6 m
From
267.25 m
To
267.85 m
Intercept Depth
267.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:267.25-267.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.091 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.091 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.091”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · silverGrade: 7.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.4
Grade Unit
g/t
Intercept
0.6 m
From
267.25 m
To
267.85 m
Intercept Depth
267.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:267.25-267.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.4 g/t·m is below.

Negative factors

  • 7.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.4”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · copperGrade: 31Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
0.6 m
From
267.25 m
To
267.85 m
Intercept Depth
267.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:267.25-267.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · leadGrade: 29Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
29
Grade Unit
g/t
Intercept
0.6 m
From
267.25 m
To
267.85 m
Intercept Depth
267.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:267.25-267.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 29 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“29”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · zincGrade: 55Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
55
Grade Unit
g/t
Intercept
0.6 m
From
267.25 m
To
267.85 m
Intercept Depth
267.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:267.25-267.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 55 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“55”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
0.7 m
From
280.25 m
To
280.95 m
Intercept Depth
280.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.25-280.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · silverGrade: 12Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.7 m
From
280.25 m
To
280.95 m
Intercept Depth
280.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.25-280.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 12 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 12 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · copperGrade: 13Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
0.7 m
From
280.25 m
To
280.95 m
Intercept Depth
280.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.25-280.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · leadGrade: 44Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
44
Grade Unit
g/t
Intercept
0.7 m
From
280.25 m
To
280.95 m
Intercept Depth
280.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.25-280.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 44 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“44”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · zincGrade: 75Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
75
Grade Unit
g/t
Intercept
0.7 m
From
280.25 m
To
280.95 m
Intercept Depth
280.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.25-280.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 75 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“75”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · goldGrade: 0.112Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.112
Grade Unit
g/t
Intercept
1.1 m
From
280.95 m
To
282.05 m
Intercept Depth
280.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.95-282.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.112 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.112 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.112”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · silverGrade: 24.4Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24.4
Grade Unit
g/t
Intercept
1.1 m
From
280.95 m
To
282.05 m
Intercept Depth
280.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.95-282.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 24.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 26.8 g/t·m is below.

Negative factors

  • 24.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“24.4”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · copperGrade: 51Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
51
Grade Unit
g/t
Intercept
1.1 m
From
280.95 m
To
282.05 m
Intercept Depth
280.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.95-282.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 51 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“51”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · leadGrade: 38Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
38
Grade Unit
g/t
Intercept
1.1 m
From
280.95 m
To
282.05 m
Intercept Depth
280.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.95-282.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 38 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“38”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-50Copalquin · zincGrade: 93Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-50
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
93
Grade Unit
g/t
Intercept
1.1 m
From
280.95 m
To
282.05 m
Intercept Depth
280.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-50:280.95-282.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 93 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“93”

Context: MTH-LS25-50

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-51Copalquin · goldGrade: 0.185Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-51
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.185
Grade Unit
g/t
Intercept
0.5 m
From
91.5 m
To
92 m
Intercept Depth
91.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-51:91.5-92

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.185 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.185 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.185”

Context: MTH-LS25-51

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-51Copalquin · silverGrade: 1.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-51
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.5
Grade Unit
g/t
Intercept
0.5 m
From
91.5 m
To
92 m
Intercept Depth
91.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-51:91.5-92

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 1.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.5”

Context: MTH-LS25-51

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-51Copalquin · copperGrade: 26Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-51
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
0.5 m
From
91.5 m
To
92 m
Intercept Depth
91.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-51:91.5-92

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-LS25-51

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-51Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-51
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.5 m
From
91.5 m
To
92 m
Intercept Depth
91.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-51:91.5-92

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-LS25-51

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-51Copalquin · zincGrade: 63Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-51
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
63
Grade Unit
g/t
Intercept
0.5 m
From
91.5 m
To
92 m
Intercept Depth
91.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-51:91.5-92

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 63 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“63”

Context: MTH-LS25-51

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.031Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.031
Grade Unit
g/t
Intercept
0.65 m
From
14.3 m
To
14.95 m
Intercept Depth
14.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:14.3-14.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.031 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.031 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.031”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 5.2Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.2
Grade Unit
g/t
Intercept
0.65 m
From
14.3 m
To
14.95 m
Intercept Depth
14.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:14.3-14.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.4 g/t·m is below.

Negative factors

  • 5.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.2”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 31Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
0.65 m
From
14.3 m
To
14.95 m
Intercept Depth
14.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:14.3-14.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 27Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.65 m
From
14.3 m
To
14.95 m
Intercept Depth
14.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:14.3-14.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 53Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
53
Grade Unit
g/t
Intercept
0.65 m
From
14.3 m
To
14.95 m
Intercept Depth
14.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:14.3-14.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 53 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“53”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 22Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
22
Grade Unit
g/t
Intercept
0.5 m
From
72.7 m
To
73.2 m
Intercept Depth
72.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:72.7-73.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 22 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“22”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.5 m
From
72.7 m
To
73.2 m
Intercept Depth
72.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:72.7-73.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 63Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
63
Grade Unit
g/t
Intercept
0.5 m
From
72.7 m
To
73.2 m
Intercept Depth
72.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:72.7-73.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 63 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“63”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.089Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.089
Grade Unit
g/t
Intercept
0.75 m
From
125.2 m
To
125.95 m
Intercept Depth
125.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:125.2-125.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.089 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.089 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.089”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 0.8Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.8
Grade Unit
g/t
Intercept
0.75 m
From
125.2 m
To
125.95 m
Intercept Depth
125.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:125.2-125.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.6 g/t·m is below.

Negative factors

  • 0.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.8”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.75 m
From
125.2 m
To
125.95 m
Intercept Depth
125.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:125.2-125.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.75 m
From
125.2 m
To
125.95 m
Intercept Depth
125.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:125.2-125.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 53Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
53
Grade Unit
g/t
Intercept
0.75 m
From
125.2 m
To
125.95 m
Intercept Depth
125.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:125.2-125.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 53 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“53”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.087Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.087
Grade Unit
g/t
Intercept
0.5 m
From
193 m
To
193.5 m
Intercept Depth
193 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:193-193.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.087 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.087 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.087”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 11Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
0.5 m
From
193 m
To
193.5 m
Intercept Depth
193 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:193-193.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 11 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.5 g/t·m is below.

Negative factors

  • 11 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“11”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.5 m
From
193 m
To
193.5 m
Intercept Depth
193 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:193-193.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 37Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
37
Grade Unit
g/t
Intercept
0.5 m
From
193 m
To
193.5 m
Intercept Depth
193 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:193-193.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 37 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“37”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 32Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
32
Grade Unit
g/t
Intercept
0.5 m
From
193 m
To
193.5 m
Intercept Depth
193 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:193-193.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 32 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“32”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.089Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.089
Grade Unit
g/t
Intercept
0.9 m
From
203.4 m
To
204.3 m
Intercept Depth
203.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:203.4-204.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.089 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.089 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.089”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 4.3Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.3
Grade Unit
g/t
Intercept
0.9 m
From
203.4 m
To
204.3 m
Intercept Depth
203.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:203.4-204.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.9 g/t·m is below.

Negative factors

  • 4.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.3”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.9 m
From
203.4 m
To
204.3 m
Intercept Depth
203.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:203.4-204.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.9 m
From
203.4 m
To
204.3 m
Intercept Depth
203.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:203.4-204.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 68Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
68
Grade Unit
g/t
Intercept
0.9 m
From
203.4 m
To
204.3 m
Intercept Depth
203.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:203.4-204.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 68 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“68”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.044Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.044
Grade Unit
g/t
Intercept
1.1 m
From
216 m
To
217.1 m
Intercept Depth
216 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:216-217.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.044 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.044 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.044”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
1.1 m
From
216 m
To
217.1 m
Intercept Depth
216 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:216-217.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.6 g/t·m is below.

Negative factors

  • 5.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.1”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
1.1 m
From
216 m
To
217.1 m
Intercept Depth
216 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:216-217.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 7Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
1.1 m
From
216 m
To
217.1 m
Intercept Depth
216 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:216-217.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 27Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
1.1 m
From
216 m
To
217.1 m
Intercept Depth
216 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:216-217.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.052Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.052
Grade Unit
g/t
Intercept
0.9 m
From
253.15 m
To
254.05 m
Intercept Depth
253.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:253.15-254.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.052 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.052 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.052”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 3.7Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
0.9 m
From
253.15 m
To
254.05 m
Intercept Depth
253.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:253.15-254.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 3.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.7”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 25Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
0.9 m
From
253.15 m
To
254.05 m
Intercept Depth
253.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:253.15-254.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.9 m
From
253.15 m
To
254.05 m
Intercept Depth
253.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:253.15-254.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 124Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
124
Grade Unit
g/t
Intercept
0.9 m
From
253.15 m
To
254.05 m
Intercept Depth
253.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:253.15-254.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 124 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“124”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · goldGrade: 0.097Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.097
Grade Unit
g/t
Intercept
1 m
From
258.4 m
To
259.4 m
Intercept Depth
258.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:258.4-259.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.097 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.097 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.097”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · silverGrade: 2.3Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.3
Grade Unit
g/t
Intercept
1 m
From
258.4 m
To
259.4 m
Intercept Depth
258.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:258.4-259.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.3 g/t·m is below.

Negative factors

  • 2.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.3”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 111Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
111
Grade Unit
g/t
Intercept
1 m
From
258.4 m
To
259.4 m
Intercept Depth
258.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:258.4-259.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 111 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“111”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 162Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
162
Grade Unit
g/t
Intercept
1 m
From
258.4 m
To
259.4 m
Intercept Depth
258.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:258.4-259.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 162 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“162”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 267Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
267
Grade Unit
g/t
Intercept
1 m
From
258.4 m
To
259.4 m
Intercept Depth
258.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:258.4-259.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 267 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“267”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · copperGrade: 79Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
79
Grade Unit
g/t
Intercept
1.5 m
From
264.5 m
To
266 m
Intercept Depth
264.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:264.5-266

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 79 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“79”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · leadGrade: 146Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
146
Grade Unit
g/t
Intercept
1.5 m
From
264.5 m
To
266 m
Intercept Depth
264.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:264.5-266

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 146 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“146”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-52Copalquin · zincGrade: 105Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-52
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
105
Grade Unit
g/t
Intercept
1.5 m
From
264.5 m
To
266 m
Intercept Depth
264.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-52:264.5-266

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.3
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 105 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“105”

Context: MTH-LS25-52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.08Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.08
Grade Unit
g/t
Intercept
1 m
From
14 m
To
15 m
Intercept Depth
14 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:14-15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.08 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.08”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
1 m
From
14 m
To
15 m
Intercept Depth
14 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:14-15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.1 g/t·m is below.

Negative factors

  • 5.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.1”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 27Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
1 m
From
14 m
To
15 m
Intercept Depth
14 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:14-15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 5Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
1 m
From
14 m
To
15 m
Intercept Depth
14 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:14-15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 90Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
90
Grade Unit
g/t
Intercept
1 m
From
14 m
To
15 m
Intercept Depth
14 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:14-15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 90 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“90”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.029Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.029
Grade Unit
g/t
Intercept
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:20-21

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.029 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.029 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.029”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 5.2Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.2
Grade Unit
g/t
Intercept
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:20-21

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.2 g/t·m is below.

Negative factors

  • 5.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.2”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 46Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
46
Grade Unit
g/t
Intercept
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:20-21

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 46 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“46”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 53Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
53
Grade Unit
g/t
Intercept
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:20-21

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 53 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“53”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 103Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
103
Grade Unit
g/t
Intercept
1 m
From
20 m
To
21 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:20-21

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 103 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“103”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.069Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.069
Grade Unit
g/t
Intercept
0.5 m
From
25.85 m
To
26.35 m
Intercept Depth
25.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:25.85-26.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.069 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.069 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.069”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 8.7Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.7
Grade Unit
g/t
Intercept
0.5 m
From
25.85 m
To
26.35 m
Intercept Depth
25.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:25.85-26.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 8.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.3 g/t·m is below.

Negative factors

  • 8.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.7”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 54Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
54
Grade Unit
g/t
Intercept
0.5 m
From
25.85 m
To
26.35 m
Intercept Depth
25.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:25.85-26.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 54 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“54”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 53Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
53
Grade Unit
g/t
Intercept
0.5 m
From
25.85 m
To
26.35 m
Intercept Depth
25.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:25.85-26.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 53 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“53”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 108Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
108
Grade Unit
g/t
Intercept
0.5 m
From
25.85 m
To
26.35 m
Intercept Depth
25.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:25.85-26.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 108 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“108”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.045Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.045
Grade Unit
g/t
Intercept
1 m
From
27 m
To
28 m
Intercept Depth
27 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:27-28

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.045 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.045 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.045”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 5.8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
1 m
From
27 m
To
28 m
Intercept Depth
27 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:27-28

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.8 g/t·m is below.

Negative factors

  • 5.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 58Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
58
Grade Unit
g/t
Intercept
1 m
From
27 m
To
28 m
Intercept Depth
27 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:27-28

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 58 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“58”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 39Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39
Grade Unit
g/t
Intercept
1 m
From
27 m
To
28 m
Intercept Depth
27 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:27-28

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 39 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“39”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 136Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
136
Grade Unit
g/t
Intercept
1 m
From
27 m
To
28 m
Intercept Depth
27 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:27-28

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 136 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“136”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.061Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.061
Grade Unit
g/t
Intercept
1 m
From
42 m
To
43 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:42-43

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.061 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.061 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.061”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 7.8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.8
Grade Unit
g/t
Intercept
1 m
From
42 m
To
43 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:42-43

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.8 g/t·m is below.

Negative factors

  • 7.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 56Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
56
Grade Unit
g/t
Intercept
1 m
From
42 m
To
43 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:42-43

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 56 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“56”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
1 m
From
42 m
To
43 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:42-43

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 124Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
124
Grade Unit
g/t
Intercept
1 m
From
42 m
To
43 m
Intercept Depth
42 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:42-43

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 124 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“124”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 65Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
65
Grade Unit
g/t
Intercept
0.5 m
From
44.7 m
To
45.2 m
Intercept Depth
44.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:44.7-45.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 65 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“65”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 27Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.5 m
From
44.7 m
To
45.2 m
Intercept Depth
44.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:44.7-45.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 85Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
85
Grade Unit
g/t
Intercept
0.5 m
From
44.7 m
To
45.2 m
Intercept Depth
44.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:44.7-45.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 85 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“85”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 134Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
134
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52-52.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 134 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“134”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 181Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
181
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52-52.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 181 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“181”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 295Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
295
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52-52.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.34
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 295 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“295”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.038Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.038
Grade Unit
g/t
Intercept
0.95 m
From
52.5 m
To
53.45 m
Intercept Depth
52.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52.5-53.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.038 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.038 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.038”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 7.8Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.8
Grade Unit
g/t
Intercept
0.95 m
From
52.5 m
To
53.45 m
Intercept Depth
52.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52.5-53.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.4 g/t·m is below.

Negative factors

  • 7.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.95 m
From
52.5 m
To
53.45 m
Intercept Depth
52.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52.5-53.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 38Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
38
Grade Unit
g/t
Intercept
0.95 m
From
52.5 m
To
53.45 m
Intercept Depth
52.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52.5-53.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 38 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“38”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 134Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
134
Grade Unit
g/t
Intercept
0.95 m
From
52.5 m
To
53.45 m
Intercept Depth
52.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:52.5-53.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 134 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“134”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.527Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.527
Grade Unit
g/t
Intercept
0.5 m
From
54.55 m
To
55.05 m
Intercept Depth
54.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:54.55-55.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.527 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.527”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 14.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14.1
Grade Unit
g/t
Intercept
0.5 m
From
54.55 m
To
55.05 m
Intercept Depth
54.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:54.55-55.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 14.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.0 g/t·m is below.

Negative factors

  • 14.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.1”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
0.5 m
From
54.55 m
To
55.05 m
Intercept Depth
54.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:54.55-55.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 30Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
30
Grade Unit
g/t
Intercept
0.5 m
From
54.55 m
To
55.05 m
Intercept Depth
54.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:54.55-55.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 30 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“30”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 133Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
133
Grade Unit
g/t
Intercept
0.5 m
From
54.55 m
To
55.05 m
Intercept Depth
54.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:54.55-55.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.73
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 133 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“133”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.49Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.49
Grade Unit
g/t
Intercept
1.15 m
From
65.25 m
To
66.4 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:65.25-66.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.49”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 0.6Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.6
Grade Unit
g/t
Intercept
1.15 m
From
65.25 m
To
66.4 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:65.25-66.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 0.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.6”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 40Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40
Grade Unit
g/t
Intercept
1.15 m
From
65.25 m
To
66.4 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:65.25-66.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 40 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“40”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 7Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
1.15 m
From
65.25 m
To
66.4 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:65.25-66.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 99Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
99
Grade Unit
g/t
Intercept
1.15 m
From
65.25 m
To
66.4 m
Intercept Depth
65.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:65.25-66.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.5
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 99 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“99”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.334Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.334
Grade Unit
g/t
Intercept
0.65 m
From
66.4 m
To
67.05 m
Intercept Depth
66.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:66.4-67.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.334 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.334”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 8.6Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.6
Grade Unit
g/t
Intercept
0.65 m
From
66.4 m
To
67.05 m
Intercept Depth
66.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:66.4-67.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 8.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.6 g/t·m is below.

Negative factors

  • 8.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.6”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 11Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
0.65 m
From
66.4 m
To
67.05 m
Intercept Depth
66.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:66.4-67.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 11 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“11”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 68Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
68
Grade Unit
g/t
Intercept
0.65 m
From
66.4 m
To
67.05 m
Intercept Depth
66.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:66.4-67.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 68 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“68”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 93Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
93
Grade Unit
g/t
Intercept
0.65 m
From
66.4 m
To
67.05 m
Intercept Depth
66.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:66.4-67.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.46
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 93 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“93”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.69Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.69
Grade Unit
g/t
Intercept
0.5 m
From
67.05 m
To
67.55 m
Intercept Depth
67.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.05-67.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.08
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.69 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.69”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 27Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.5 m
From
67.05 m
To
67.55 m
Intercept Depth
67.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.05-67.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.08
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 27 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 13.5 g/t·m is below.

Negative factors

  • 27 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“27”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
0.5 m
From
67.05 m
To
67.55 m
Intercept Depth
67.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.05-67.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.08
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 17Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
17
Grade Unit
g/t
Intercept
0.5 m
From
67.05 m
To
67.55 m
Intercept Depth
67.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.05-67.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.08
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 17 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“17”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 14Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
0.5 m
From
67.05 m
To
67.55 m
Intercept Depth
67.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.05-67.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.08
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 23Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
0.5 m
From
67.55 m
To
68.05 m
Intercept Depth
67.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.55-68.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 113Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
113
Grade Unit
g/t
Intercept
0.5 m
From
67.55 m
To
68.05 m
Intercept Depth
67.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.55-68.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 113 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“113”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 159Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
159
Grade Unit
g/t
Intercept
0.5 m
From
67.55 m
To
68.05 m
Intercept Depth
67.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:67.55-68.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.81
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 159 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“159”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 1.305Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.305
Grade Unit
g/t
Intercept
0.55 m
From
77.2 m
To
77.75 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.2-77.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.68
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.305 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.305”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 25.9Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25.9
Grade Unit
g/t
Intercept
0.55 m
From
77.2 m
To
77.75 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.2-77.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.68
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 25.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.2 g/t·m is below.

Negative factors

  • 25.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“25.9”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 34Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
34
Grade Unit
g/t
Intercept
0.55 m
From
77.2 m
To
77.75 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.2-77.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.68
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 34 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“34”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 73Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
73
Grade Unit
g/t
Intercept
0.55 m
From
77.2 m
To
77.75 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.2-77.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.68
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 73 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“73”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 180Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
180
Grade Unit
g/t
Intercept
0.55 m
From
77.2 m
To
77.75 m
Intercept Depth
77.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.2-77.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.68
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 180 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“180”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.566Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.566
Grade Unit
g/t
Intercept
1.05 m
From
77.75 m
To
78.8 m
Intercept Depth
77.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.75-78.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.566 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.566”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 3.1Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.1
Grade Unit
g/t
Intercept
1.05 m
From
77.75 m
To
78.8 m
Intercept Depth
77.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.75-78.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 3.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.1”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 32Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
32
Grade Unit
g/t
Intercept
1.05 m
From
77.75 m
To
78.8 m
Intercept Depth
77.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.75-78.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 32 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“32”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 28Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
28
Grade Unit
g/t
Intercept
1.05 m
From
77.75 m
To
78.8 m
Intercept Depth
77.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.75-78.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 28 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“28”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 176Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
176
Grade Unit
g/t
Intercept
1.05 m
From
77.75 m
To
78.8 m
Intercept Depth
77.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:77.75-78.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 176 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“176”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.169Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.169
Grade Unit
g/t
Intercept
1 m
From
78.8 m
To
79.8 m
Intercept Depth
78.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:78.8-79.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.169 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.169 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.169”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 3.4Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.4
Grade Unit
g/t
Intercept
1 m
From
78.8 m
To
79.8 m
Intercept Depth
78.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:78.8-79.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.4 g/t·m is below.

Negative factors

  • 3.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.4”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 31Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
1 m
From
78.8 m
To
79.8 m
Intercept Depth
78.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:78.8-79.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 31Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
1 m
From
78.8 m
To
79.8 m
Intercept Depth
78.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:78.8-79.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 127Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
127
Grade Unit
g/t
Intercept
1 m
From
78.8 m
To
79.8 m
Intercept Depth
78.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:78.8-79.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 127 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“127”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.437Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.437
Grade Unit
g/t
Intercept
0.75 m
From
80.35 m
To
81.1 m
Intercept Depth
80.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:80.35-81.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.437 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.437”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 11.2Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.2
Grade Unit
g/t
Intercept
0.75 m
From
80.35 m
To
81.1 m
Intercept Depth
80.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:80.35-81.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 11.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 11.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“11.2”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.75 m
From
80.35 m
To
81.1 m
Intercept Depth
80.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:80.35-81.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 18Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18
Grade Unit
g/t
Intercept
0.75 m
From
80.35 m
To
81.1 m
Intercept Depth
80.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:80.35-81.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 18 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“18”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 42Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
42
Grade Unit
g/t
Intercept
0.75 m
From
80.35 m
To
81.1 m
Intercept Depth
80.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:80.35-81.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 42 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“42”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 33Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
33
Grade Unit
g/t
Intercept
0.5 m
From
81.1 m
To
81.6 m
Intercept Depth
81.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:81.1-81.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.44
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 33 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“33”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 109Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
109
Grade Unit
g/t
Intercept
0.5 m
From
81.1 m
To
81.6 m
Intercept Depth
81.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:81.1-81.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.44
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 109 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“109”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 135Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
135
Grade Unit
g/t
Intercept
0.5 m
From
81.1 m
To
81.6 m
Intercept Depth
81.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:81.1-81.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.44
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 135 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“135”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.059Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.059
Grade Unit
g/t
Intercept
1.1 m
From
82.85 m
To
83.95 m
Intercept Depth
82.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:82.85-83.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.059 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.059 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.059”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 3.7Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
1.1 m
From
82.85 m
To
83.95 m
Intercept Depth
82.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:82.85-83.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.1 g/t·m is below.

Negative factors

  • 3.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.7”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
1.1 m
From
82.85 m
To
83.95 m
Intercept Depth
82.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:82.85-83.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 15Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
1.1 m
From
82.85 m
To
83.95 m
Intercept Depth
82.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:82.85-83.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 103Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
103
Grade Unit
g/t
Intercept
1.1 m
From
82.85 m
To
83.95 m
Intercept Depth
82.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:82.85-83.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 103 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“103”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
1.3 m
From
91.7 m
To
93 m
Intercept Depth
91.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:91.7-93

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.45
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 38Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
38
Grade Unit
g/t
Intercept
1.3 m
From
91.7 m
To
93 m
Intercept Depth
91.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:91.7-93

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.45
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 38 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“38”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 109Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
109
Grade Unit
g/t
Intercept
1.3 m
From
91.7 m
To
93 m
Intercept Depth
91.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:91.7-93

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.45
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 109 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“109”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.366Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.366
Grade Unit
g/t
Intercept
0.55 m
From
102.3 m
To
102.85 m
Intercept Depth
102.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:102.3-102.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.366 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.366”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 3.1Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.1
Grade Unit
g/t
Intercept
0.55 m
From
102.3 m
To
102.85 m
Intercept Depth
102.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:102.3-102.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.7 g/t·m is below.

Negative factors

  • 3.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.1”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 40Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40
Grade Unit
g/t
Intercept
0.55 m
From
102.3 m
To
102.85 m
Intercept Depth
102.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:102.3-102.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 40 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“40”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
0.55 m
From
102.3 m
To
102.85 m
Intercept Depth
102.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:102.3-102.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 27Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.55 m
From
102.3 m
To
102.85 m
Intercept Depth
102.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:102.3-102.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.229Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.229
Grade Unit
g/t
Intercept
0.6 m
From
112.5 m
To
113.1 m
Intercept Depth
112.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:112.5-113.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.229 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.229 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.229”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 3Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.6 m
From
112.5 m
To
113.1 m
Intercept Depth
112.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:112.5-113.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.8 g/t·m is below.

Negative factors

  • 3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 16Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.6 m
From
112.5 m
To
113.1 m
Intercept Depth
112.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:112.5-113.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 17Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
17
Grade Unit
g/t
Intercept
0.6 m
From
112.5 m
To
113.1 m
Intercept Depth
112.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:112.5-113.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 17 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“17”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 54Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
54
Grade Unit
g/t
Intercept
0.6 m
From
112.5 m
To
113.1 m
Intercept Depth
112.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:112.5-113.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 54 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“54”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.093Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.093
Grade Unit
g/t
Intercept
1.4 m
From
131.4 m
To
132.8 m
Intercept Depth
131.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:131.4-132.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.093 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.093 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.093”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 2.6Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.6
Grade Unit
g/t
Intercept
1.4 m
From
131.4 m
To
132.8 m
Intercept Depth
131.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:131.4-132.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 2.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.6”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 8Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
1.4 m
From
131.4 m
To
132.8 m
Intercept Depth
131.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:131.4-132.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 8 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
1.4 m
From
131.4 m
To
132.8 m
Intercept Depth
131.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:131.4-132.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 127Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
127
Grade Unit
g/t
Intercept
1.4 m
From
131.4 m
To
132.8 m
Intercept Depth
131.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:131.4-132.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 127 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“127”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.099Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.099
Grade Unit
g/t
Intercept
1.4 m
From
137.1 m
To
138.5 m
Intercept Depth
137.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:137.1-138.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.099 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.099 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.099”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 1.3Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.3
Grade Unit
g/t
Intercept
1.4 m
From
137.1 m
To
138.5 m
Intercept Depth
137.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:137.1-138.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.8 g/t·m is below.

Negative factors

  • 1.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.3”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 6Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.4 m
From
137.1 m
To
138.5 m
Intercept Depth
137.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:137.1-138.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 6 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“6”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 27Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
1.4 m
From
137.1 m
To
138.5 m
Intercept Depth
137.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:137.1-138.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 97Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
97
Grade Unit
g/t
Intercept
1.4 m
From
137.1 m
To
138.5 m
Intercept Depth
137.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:137.1-138.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 97 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“97”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 59Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
59
Grade Unit
g/t
Intercept
0.5 m
From
226 m
To
226.5 m
Intercept Depth
226 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:226-226.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 59 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“59”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 99Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
99
Grade Unit
g/t
Intercept
0.5 m
From
226 m
To
226.5 m
Intercept Depth
226 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:226-226.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 99 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“99”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 137Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
137
Grade Unit
g/t
Intercept
0.5 m
From
226 m
To
226.5 m
Intercept Depth
226 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:226-226.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 137 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“137”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.125Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.125
Grade Unit
g/t
Intercept
0.6 m
From
250.75 m
To
251.35 m
Intercept Depth
250.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:250.75-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.125 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.125 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.125”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 1.1Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
0.6 m
From
250.75 m
To
251.35 m
Intercept Depth
250.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:250.75-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 1.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.1”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 25Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
0.6 m
From
250.75 m
To
251.35 m
Intercept Depth
250.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:250.75-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 11Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
0.6 m
From
250.75 m
To
251.35 m
Intercept Depth
250.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:250.75-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 11 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“11”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 69Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
69
Grade Unit
g/t
Intercept
0.6 m
From
250.75 m
To
251.35 m
Intercept Depth
250.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:250.75-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 69 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“69”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.042Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.042
Grade Unit
g/t
Intercept
1.25 m
From
284.75 m
To
286 m
Intercept Depth
284.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:284.75-286

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.042 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.042 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.042”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 7.7Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.7
Grade Unit
g/t
Intercept
1.25 m
From
284.75 m
To
286 m
Intercept Depth
284.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:284.75-286

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 9.6 g/t·m is below.

Negative factors

  • 7.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.7”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 14Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
1.25 m
From
284.75 m
To
286 m
Intercept Depth
284.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:284.75-286

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 52Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
52
Grade Unit
g/t
Intercept
1.25 m
From
284.75 m
To
286 m
Intercept Depth
284.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:284.75-286

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 52 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“52”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 15Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
1.25 m
From
284.75 m
To
286 m
Intercept Depth
284.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:284.75-286

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.103Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.103
Grade Unit
g/t
Intercept
0.5 m
From
286.75 m
To
287.25 m
Intercept Depth
286.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:286.75-287.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.103 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.103 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.103”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 7.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.5
Grade Unit
g/t
Intercept
0.5 m
From
286.75 m
To
287.25 m
Intercept Depth
286.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:286.75-287.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.8 g/t·m is below.

Negative factors

  • 7.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.5”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
0.5 m
From
286.75 m
To
287.25 m
Intercept Depth
286.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:286.75-287.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 6 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“6”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.5 m
From
286.75 m
To
287.25 m
Intercept Depth
286.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:286.75-287.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 157Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
157
Grade Unit
g/t
Intercept
0.5 m
From
286.75 m
To
287.25 m
Intercept Depth
286.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:286.75-287.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 157 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“157”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.095Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.095
Grade Unit
g/t
Intercept
0.6 m
From
296 m
To
296.6 m
Intercept Depth
296 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:296-296.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.095 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.095 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.095”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 1.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.4
Grade Unit
g/t
Intercept
0.6 m
From
296 m
To
296.6 m
Intercept Depth
296 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:296-296.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 1.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.4”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.6 m
From
296 m
To
296.6 m
Intercept Depth
296 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:296-296.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.6 m
From
296 m
To
296.6 m
Intercept Depth
296 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:296-296.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 18Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18
Grade Unit
g/t
Intercept
0.6 m
From
296 m
To
296.6 m
Intercept Depth
296 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:296-296.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 18 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“18”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.08Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.08
Grade Unit
g/t
Intercept
1.15 m
From
298.55 m
To
299.7 m
Intercept Depth
298.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:298.55-299.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.08 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.08”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 12.1Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12.1
Grade Unit
g/t
Intercept
1.15 m
From
298.55 m
To
299.7 m
Intercept Depth
298.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:298.55-299.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 12.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 13.9 g/t·m is below.

Negative factors

  • 12.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12.1”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 787Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
787
Grade Unit
g/t
Intercept
1.15 m
From
298.55 m
To
299.7 m
Intercept Depth
298.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:298.55-299.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 787 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“787”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 588Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
588
Grade Unit
g/t
Intercept
1.15 m
From
298.55 m
To
299.7 m
Intercept Depth
298.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:298.55-299.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 588 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“588”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 301Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
301
Grade Unit
g/t
Intercept
1.15 m
From
298.55 m
To
299.7 m
Intercept Depth
298.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:298.55-299.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 301 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“301”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.06Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.06
Grade Unit
g/t
Intercept
1.15 m
From
299.7 m
To
300.85 m
Intercept Depth
299.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:299.7-300.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.06 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 4.5Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.5
Grade Unit
g/t
Intercept
1.15 m
From
299.7 m
To
300.85 m
Intercept Depth
299.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:299.7-300.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.2 g/t·m is below.

Negative factors

  • 4.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.5”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 176Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
176
Grade Unit
g/t
Intercept
1.15 m
From
299.7 m
To
300.85 m
Intercept Depth
299.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:299.7-300.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 176 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“176”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 121Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
121
Grade Unit
g/t
Intercept
1.15 m
From
299.7 m
To
300.85 m
Intercept Depth
299.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:299.7-300.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 121 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“121”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 129Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
129
Grade Unit
g/t
Intercept
1.15 m
From
299.7 m
To
300.85 m
Intercept Depth
299.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:299.7-300.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 129 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“129”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.114Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.114
Grade Unit
g/t
Intercept
0.7 m
From
301.65 m
To
302.35 m
Intercept Depth
301.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:301.65-302.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.114 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.114 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.114”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 0.8Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.8
Grade Unit
g/t
Intercept
0.7 m
From
301.65 m
To
302.35 m
Intercept Depth
301.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:301.65-302.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.6 g/t·m is below.

Negative factors

  • 0.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 2Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
0.7 m
From
301.65 m
To
302.35 m
Intercept Depth
301.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:301.65-302.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“2”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 9Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
0.7 m
From
301.65 m
To
302.35 m
Intercept Depth
301.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:301.65-302.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 25Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
0.7 m
From
301.65 m
To
302.35 m
Intercept Depth
301.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:301.65-302.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.228Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.228
Grade Unit
g/t
Intercept
0.8 m
From
305 m
To
305.8 m
Intercept Depth
305 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305-305.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.228 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.228 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.228”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 3.9Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.9
Grade Unit
g/t
Intercept
0.8 m
From
305 m
To
305.8 m
Intercept Depth
305 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305-305.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.1 g/t·m is below.

Negative factors

  • 3.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.9”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 27Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.8 m
From
305 m
To
305.8 m
Intercept Depth
305 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305-305.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 39Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39
Grade Unit
g/t
Intercept
0.8 m
From
305 m
To
305.8 m
Intercept Depth
305 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305-305.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 39 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“39”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 78Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
78
Grade Unit
g/t
Intercept
0.8 m
From
305 m
To
305.8 m
Intercept Depth
305 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305-305.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.28
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 78 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“78”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.705Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.705
Grade Unit
g/t
Intercept
0.5 m
From
305.8 m
To
306.3 m
Intercept Depth
305.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305.8-306.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.705 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.705”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 2.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.2
Grade Unit
g/t
Intercept
0.5 m
From
305.8 m
To
306.3 m
Intercept Depth
305.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305.8-306.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.1 g/t·m is below.

Negative factors

  • 2.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.2”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 19Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.5 m
From
305.8 m
To
306.3 m
Intercept Depth
305.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305.8-306.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.5 m
From
305.8 m
To
306.3 m
Intercept Depth
305.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305.8-306.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 57Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
57
Grade Unit
g/t
Intercept
0.5 m
From
305.8 m
To
306.3 m
Intercept Depth
305.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:305.8-306.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.74
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 57 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“57”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.296Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.296
Grade Unit
g/t
Intercept
0.85 m
From
306.3 m
To
307.15 m
Intercept Depth
306.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:306.3-307.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.296 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.296 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.296”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 2.6Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.6
Grade Unit
g/t
Intercept
0.85 m
From
306.3 m
To
307.15 m
Intercept Depth
306.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:306.3-307.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.2 g/t·m is below.

Negative factors

  • 2.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.6”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
0.85 m
From
306.3 m
To
307.15 m
Intercept Depth
306.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:306.3-307.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 46Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
46
Grade Unit
g/t
Intercept
0.85 m
From
306.3 m
To
307.15 m
Intercept Depth
306.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:306.3-307.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 46 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“46”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 82Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
82
Grade Unit
g/t
Intercept
0.85 m
From
306.3 m
To
307.15 m
Intercept Depth
306.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:306.3-307.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 82 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“82”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
0.65 m
From
307.15 m
To
307.8 m
Intercept Depth
307.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.15-307.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 5.5Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.5
Grade Unit
g/t
Intercept
0.65 m
From
307.15 m
To
307.8 m
Intercept Depth
307.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.15-307.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 5.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.5”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 78Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
78
Grade Unit
g/t
Intercept
0.65 m
From
307.15 m
To
307.8 m
Intercept Depth
307.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.15-307.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 78 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“78”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 523Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
523
Grade Unit
g/t
Intercept
0.65 m
From
307.15 m
To
307.8 m
Intercept Depth
307.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.15-307.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 523 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“523”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 363Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
363
Grade Unit
g/t
Intercept
0.65 m
From
307.15 m
To
307.8 m
Intercept Depth
307.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.15-307.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 363 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“363”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.068Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.068
Grade Unit
g/t
Intercept
1.15 m
From
307.8 m
To
308.95 m
Intercept Depth
307.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.8-308.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.068 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.068 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.068”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 5.7Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.7
Grade Unit
g/t
Intercept
1.15 m
From
307.8 m
To
308.95 m
Intercept Depth
307.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.8-308.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.6 g/t·m is below.

Negative factors

  • 5.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.7”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 19Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
1.15 m
From
307.8 m
To
308.95 m
Intercept Depth
307.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.8-308.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 66Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
66
Grade Unit
g/t
Intercept
1.15 m
From
307.8 m
To
308.95 m
Intercept Depth
307.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.8-308.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 66 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“66”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 64Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
64
Grade Unit
g/t
Intercept
1.15 m
From
307.8 m
To
308.95 m
Intercept Depth
307.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:307.8-308.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 64 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“64”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.168Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.168
Grade Unit
g/t
Intercept
0.7 m
From
312.05 m
To
312.75 m
Intercept Depth
312.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:312.05-312.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.168 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.168 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.168”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 1.8Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.8
Grade Unit
g/t
Intercept
0.7 m
From
312.05 m
To
312.75 m
Intercept Depth
312.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:312.05-312.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.3 g/t·m is below.

Negative factors

  • 1.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 16Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.7 m
From
312.05 m
To
312.75 m
Intercept Depth
312.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:312.05-312.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 72Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
72
Grade Unit
g/t
Intercept
0.7 m
From
312.05 m
To
312.75 m
Intercept Depth
312.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:312.05-312.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 72 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“72”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 89Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
89
Grade Unit
g/t
Intercept
0.7 m
From
312.05 m
To
312.75 m
Intercept Depth
312.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:312.05-312.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 89 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“89”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.088Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.088
Grade Unit
g/t
Intercept
1.05 m
From
336.25 m
To
337.3 m
Intercept Depth
336.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:336.25-337.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.088 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.088 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.088”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 0.9Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.9
Grade Unit
g/t
Intercept
1.05 m
From
336.25 m
To
337.3 m
Intercept Depth
336.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:336.25-337.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.9 g/t·m is below.

Negative factors

  • 0.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.9”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 44Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
44
Grade Unit
g/t
Intercept
1.05 m
From
336.25 m
To
337.3 m
Intercept Depth
336.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:336.25-337.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 44 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“44”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 54Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
54
Grade Unit
g/t
Intercept
1.05 m
From
336.25 m
To
337.3 m
Intercept Depth
336.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:336.25-337.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 54 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“54”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 194Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
194
Grade Unit
g/t
Intercept
1.05 m
From
336.25 m
To
337.3 m
Intercept Depth
336.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:336.25-337.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 194 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“194”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · goldGrade: 0.095Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.095
Grade Unit
g/t
Intercept
1.05 m
From
337.3 m
To
338.35 m
Intercept Depth
337.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:337.3-338.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.095 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.095 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.095”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · silverGrade: 0.8Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.8
Grade Unit
g/t
Intercept
1.05 m
From
337.3 m
To
338.35 m
Intercept Depth
337.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:337.3-338.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 0.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.8”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · copperGrade: 54Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
54
Grade Unit
g/t
Intercept
1.05 m
From
337.3 m
To
338.35 m
Intercept Depth
337.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:337.3-338.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 54 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“54”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · leadGrade: 47Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
47
Grade Unit
g/t
Intercept
1.05 m
From
337.3 m
To
338.35 m
Intercept Depth
337.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:337.3-338.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 47 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“47”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-LS25-53Copalquin · zincGrade: 191Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-LS25-53
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
191
Grade Unit
g/t
Intercept
1.05 m
From
337.3 m
To
338.35 m
Intercept Depth
337.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-LS25-53:337.3-338.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 191 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“191”

Context: MTH-LS25-53

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.093Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.093
Grade Unit
g/t
Intercept
2.95 m
From
1 m
To
3.95 m
Intercept Depth
1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:1-3.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.093 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.093 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.093”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.1Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.1
Grade Unit
g/t
Intercept
2.95 m
From
1 m
To
3.95 m
Intercept Depth
1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:1-3.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 9.1 g/t·m is below.

Negative factors

  • 3.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.1”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 14Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
2.95 m
From
1 m
To
3.95 m
Intercept Depth
1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:1-3.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
2.95 m
From
1 m
To
3.95 m
Intercept Depth
1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:1-3.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 25Grade Unit: g/tIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
2.95 m
From
1 m
To
3.95 m
Intercept Depth
1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:1-3.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.113Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.113
Grade Unit
g/t
Intercept
1.55 m
From
3.95 m
To
5.5 m
Intercept Depth
3.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:3.95-5.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.113 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.113 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.113”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 10.4Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.4
Grade Unit
g/t
Intercept
1.55 m
From
3.95 m
To
5.5 m
Intercept Depth
3.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:3.95-5.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.1 g/t·m is below.

Negative factors

  • 10.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
1.55 m
From
3.95 m
To
5.5 m
Intercept Depth
3.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:3.95-5.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
1.55 m
From
3.95 m
To
5.5 m
Intercept Depth
3.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:3.95-5.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 20Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20
Grade Unit
g/t
Intercept
1.55 m
From
3.95 m
To
5.5 m
Intercept Depth
3.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:3.95-5.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 20 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“20”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.205Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.205
Grade Unit
g/t
Intercept
0.9 m
From
5.5 m
To
6.4 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:5.5-6.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.205 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.205 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.205”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 13Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
0.9 m
From
5.5 m
To
6.4 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:5.5-6.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 13 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.7 g/t·m is below.

Negative factors

  • 13 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 28Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
28
Grade Unit
g/t
Intercept
0.9 m
From
5.5 m
To
6.4 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:5.5-6.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 28 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“28”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.9 m
From
5.5 m
To
6.4 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:5.5-6.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 15Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.9 m
From
5.5 m
To
6.4 m
Intercept Depth
5.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:5.5-6.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.39
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.311Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.311
Grade Unit
g/t
Intercept
1.05 m
From
6.4 m
To
7.45 m
Intercept Depth
6.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:6.4-7.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.66
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.311 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.311”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 24.5Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24.5
Grade Unit
g/t
Intercept
1.05 m
From
6.4 m
To
7.45 m
Intercept Depth
6.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:6.4-7.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.66
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 24.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 25.7 g/t·m is below.

Negative factors

  • 24.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“24.5”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 15Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
1.05 m
From
6.4 m
To
7.45 m
Intercept Depth
6.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:6.4-7.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.66
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
1.05 m
From
6.4 m
To
7.45 m
Intercept Depth
6.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:6.4-7.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.66
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 19Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
1.05 m
From
6.4 m
To
7.45 m
Intercept Depth
6.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:6.4-7.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.66
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.303Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.303
Grade Unit
g/t
Intercept
0.85 m
From
7.45 m
To
8.3 m
Intercept Depth
7.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:7.45-8.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.303 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.303”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 21Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.85 m
From
7.45 m
To
8.3 m
Intercept Depth
7.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:7.45-8.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 21 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 17.8 g/t·m is below.

Negative factors

  • 21 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“21”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 17Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
17
Grade Unit
g/t
Intercept
0.85 m
From
7.45 m
To
8.3 m
Intercept Depth
7.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:7.45-8.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 17 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“17”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 33Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
33
Grade Unit
g/t
Intercept
0.85 m
From
7.45 m
To
8.3 m
Intercept Depth
7.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:7.45-8.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 33 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“33”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 23Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
0.85 m
From
7.45 m
To
8.3 m
Intercept Depth
7.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:7.45-8.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.098Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.098
Grade Unit
g/t
Intercept
0.55 m
From
9.25 m
To
9.8 m
Intercept Depth
9.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:9.25-9.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.098 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.098 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.098”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 6.6Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.6
Grade Unit
g/t
Intercept
0.55 m
From
9.25 m
To
9.8 m
Intercept Depth
9.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:9.25-9.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 6.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 25Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
0.55 m
From
9.25 m
To
9.8 m
Intercept Depth
9.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:9.25-9.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
0.55 m
From
9.25 m
To
9.8 m
Intercept Depth
9.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:9.25-9.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 120Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
120
Grade Unit
g/t
Intercept
0.55 m
From
9.25 m
To
9.8 m
Intercept Depth
9.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:9.25-9.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.19
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 120 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“120”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.051Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.051
Grade Unit
g/t
Intercept
0.8 m
From
10.3 m
To
11.1 m
Intercept Depth
10.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:10.3-11.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.051 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.051 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.051”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.8 m
From
10.3 m
To
11.1 m
Intercept Depth
10.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:10.3-11.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.2 g/t·m is below.

Negative factors

  • 4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 20Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20
Grade Unit
g/t
Intercept
0.8 m
From
10.3 m
To
11.1 m
Intercept Depth
10.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:10.3-11.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 20 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“20”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.8 m
From
10.3 m
To
11.1 m
Intercept Depth
10.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:10.3-11.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 52Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
52
Grade Unit
g/t
Intercept
0.8 m
From
10.3 m
To
11.1 m
Intercept Depth
10.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:10.3-11.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 52 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“52”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.075Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.075
Grade Unit
g/t
Intercept
0.9 m
From
11.1 m
To
12 m
Intercept Depth
11.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:11.1-12

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.075 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.075 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.075”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4.6Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.6
Grade Unit
g/t
Intercept
0.9 m
From
11.1 m
To
12 m
Intercept Depth
11.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:11.1-12

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.1 g/t·m is below.

Negative factors

  • 4.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
0.9 m
From
11.1 m
To
12 m
Intercept Depth
11.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:11.1-12

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 13Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
0.9 m
From
11.1 m
To
12 m
Intercept Depth
11.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:11.1-12

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 108Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
108
Grade Unit
g/t
Intercept
0.9 m
From
11.1 m
To
12 m
Intercept Depth
11.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:11.1-12

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 108 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“108”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 33Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
33
Grade Unit
g/t
Intercept
0.65 m
From
12 m
To
12.65 m
Intercept Depth
12 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:12-12.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.87
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 33 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“33”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 75Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
75
Grade Unit
g/t
Intercept
0.65 m
From
12 m
To
12.65 m
Intercept Depth
12 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:12-12.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.87
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 75 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“75”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 140Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
140
Grade Unit
g/t
Intercept
0.65 m
From
12 m
To
12.65 m
Intercept Depth
12 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:12-12.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.87
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 140 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“140”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.113Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.113
Grade Unit
g/t
Intercept
1.25 m
From
15.1 m
To
16.35 m
Intercept Depth
15.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:15.1-16.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.113 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.113 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.113”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 7.4Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.4
Grade Unit
g/t
Intercept
1.25 m
From
15.1 m
To
16.35 m
Intercept Depth
15.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:15.1-16.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 9.3 g/t·m is below.

Negative factors

  • 7.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 22Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
22
Grade Unit
g/t
Intercept
1.25 m
From
15.1 m
To
16.35 m
Intercept Depth
15.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:15.1-16.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 22 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“22”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
1.25 m
From
15.1 m
To
16.35 m
Intercept Depth
15.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:15.1-16.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 95Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
95
Grade Unit
g/t
Intercept
1.25 m
From
15.1 m
To
16.35 m
Intercept Depth
15.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:15.1-16.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 95 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“95”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.115Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.115
Grade Unit
g/t
Intercept
1.25 m
From
16.35 m
To
17.6 m
Intercept Depth
16.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:16.35-17.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.115 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.115 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.115”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 6.4Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.4
Grade Unit
g/t
Intercept
1.25 m
From
16.35 m
To
17.6 m
Intercept Depth
16.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:16.35-17.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.0 g/t·m is below.

Negative factors

  • 6.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 23Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
1.25 m
From
16.35 m
To
17.6 m
Intercept Depth
16.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:16.35-17.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 40Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40
Grade Unit
g/t
Intercept
1.25 m
From
16.35 m
To
17.6 m
Intercept Depth
16.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:16.35-17.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 40 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“40”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 96Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
96
Grade Unit
g/t
Intercept
1.25 m
From
16.35 m
To
17.6 m
Intercept Depth
16.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:16.35-17.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 96 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“96”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.053Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.053
Grade Unit
g/t
Intercept
0.65 m
From
18.2 m
To
18.85 m
Intercept Depth
18.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.2-18.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.053 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.053 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.053”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4.4Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.4
Grade Unit
g/t
Intercept
0.65 m
From
18.2 m
To
18.85 m
Intercept Depth
18.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.2-18.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.9 g/t·m is below.

Negative factors

  • 4.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 29Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
29
Grade Unit
g/t
Intercept
0.65 m
From
18.2 m
To
18.85 m
Intercept Depth
18.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.2-18.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 29 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“29”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.65 m
From
18.2 m
To
18.85 m
Intercept Depth
18.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.2-18.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 98Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
98
Grade Unit
g/t
Intercept
0.65 m
From
18.2 m
To
18.85 m
Intercept Depth
18.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.2-18.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 98 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“98”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 29Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
29
Grade Unit
g/t
Intercept
1.15 m
From
18.85 m
To
20 m
Intercept Depth
18.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.85-20

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.47
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 29 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“29”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
1.15 m
From
18.85 m
To
20 m
Intercept Depth
18.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.85-20

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.47
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 91Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
91
Grade Unit
g/t
Intercept
1.15 m
From
18.85 m
To
20 m
Intercept Depth
18.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:18.85-20

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.47
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 91 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“91”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.087Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.087
Grade Unit
g/t
Intercept
1 m
From
23 m
To
24 m
Intercept Depth
23 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:23-24

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.087 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.087 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.087”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
1 m
From
23 m
To
24 m
Intercept Depth
23 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:23-24

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.0 g/t·m is below.

Negative factors

  • 4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 31Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
1 m
From
23 m
To
24 m
Intercept Depth
23 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:23-24

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
1 m
From
23 m
To
24 m
Intercept Depth
23 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:23-24

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 82Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
82
Grade Unit
g/t
Intercept
1 m
From
23 m
To
24 m
Intercept Depth
23 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:23-24

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 82 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“82”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.319Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.319
Grade Unit
g/t
Intercept
0.75 m
From
24.65 m
To
25.4 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:24.65-25.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.38
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.319 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.319”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.75 m
From
24.65 m
To
25.4 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:24.65-25.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.38
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.0 g/t·m is below.

Negative factors

  • 4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 43Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
43
Grade Unit
g/t
Intercept
0.75 m
From
24.65 m
To
25.4 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:24.65-25.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.38
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 43 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“43”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.75 m
From
24.65 m
To
25.4 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:24.65-25.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.38
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 85Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
85
Grade Unit
g/t
Intercept
0.75 m
From
24.65 m
To
25.4 m
Intercept Depth
24.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:24.65-25.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.38
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 85 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“85”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 3.79Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.79
Grade Unit
g/t
Intercept
0.8 m
From
25.4 m
To
26.2 m
Intercept Depth
25.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:25.4-26.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.79 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.0 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 3.79 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.79”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 6.9Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.9
Grade Unit
g/t
Intercept
0.8 m
From
25.4 m
To
26.2 m
Intercept Depth
25.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:25.4-26.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.5 g/t·m is below.

Negative factors

  • 6.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.9”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 53Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
53
Grade Unit
g/t
Intercept
0.8 m
From
25.4 m
To
26.2 m
Intercept Depth
25.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:25.4-26.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 53 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“53”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.8 m
From
25.4 m
To
26.2 m
Intercept Depth
25.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:25.4-26.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 109Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
109
Grade Unit
g/t
Intercept
0.8 m
From
25.4 m
To
26.2 m
Intercept Depth
25.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:25.4-26.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 109 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“109”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.119Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.119
Grade Unit
g/t
Intercept
0.8 m
From
26.2 m
To
27 m
Intercept Depth
26.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:26.2-27

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.119 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.119 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.119”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4.4Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.4
Grade Unit
g/t
Intercept
0.8 m
From
26.2 m
To
27 m
Intercept Depth
26.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:26.2-27

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.5 g/t·m is below.

Negative factors

  • 4.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 52Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
52
Grade Unit
g/t
Intercept
0.8 m
From
26.2 m
To
27 m
Intercept Depth
26.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:26.2-27

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 52 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“52”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
0.8 m
From
26.2 m
To
27 m
Intercept Depth
26.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:26.2-27

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 137Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
137
Grade Unit
g/t
Intercept
0.8 m
From
26.2 m
To
27 m
Intercept Depth
26.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:26.2-27

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 137 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“137”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.123Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.123
Grade Unit
g/t
Intercept
0.95 m
From
27.75 m
To
28.7 m
Intercept Depth
27.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:27.75-28.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.123 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.123 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.123”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 5.2Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.2
Grade Unit
g/t
Intercept
0.95 m
From
27.75 m
To
28.7 m
Intercept Depth
27.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:27.75-28.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.9 g/t·m is below.

Negative factors

  • 5.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 50Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
50
Grade Unit
g/t
Intercept
0.95 m
From
27.75 m
To
28.7 m
Intercept Depth
27.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:27.75-28.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 50 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“50”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 28Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
28
Grade Unit
g/t
Intercept
0.95 m
From
27.75 m
To
28.7 m
Intercept Depth
27.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:27.75-28.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 28 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“28”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 132Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
132
Grade Unit
g/t
Intercept
0.95 m
From
27.75 m
To
28.7 m
Intercept Depth
27.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:27.75-28.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 132 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“132”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 16Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.9 m
From
28.7 m
To
29.6 m
Intercept Depth
28.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:28.7-29.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 75Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
75
Grade Unit
g/t
Intercept
0.9 m
From
28.7 m
To
29.6 m
Intercept Depth
28.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:28.7-29.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 75 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“75”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 111Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
111
Grade Unit
g/t
Intercept
0.9 m
From
28.7 m
To
29.6 m
Intercept Depth
28.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:28.7-29.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.85
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 111 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“111”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.146Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.146
Grade Unit
g/t
Intercept
0.5 m
From
29.6 m
To
30.1 m
Intercept Depth
29.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:29.6-30.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.146 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.146 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.146”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.7Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
0.5 m
From
29.6 m
To
30.1 m
Intercept Depth
29.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:29.6-30.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.9 g/t·m is below.

Negative factors

  • 3.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 28Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
28
Grade Unit
g/t
Intercept
0.5 m
From
29.6 m
To
30.1 m
Intercept Depth
29.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:29.6-30.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 28 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“28”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 20Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20
Grade Unit
g/t
Intercept
0.5 m
From
29.6 m
To
30.1 m
Intercept Depth
29.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:29.6-30.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 20 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“20”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 101Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
101
Grade Unit
g/t
Intercept
0.5 m
From
29.6 m
To
30.1 m
Intercept Depth
29.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:29.6-30.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 101 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“101”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.069Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.069
Grade Unit
g/t
Intercept
1.2 m
From
30.1 m
To
31.3 m
Intercept Depth
30.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:30.1-31.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.069 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.069 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.069”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2.6Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.6
Grade Unit
g/t
Intercept
1.2 m
From
30.1 m
To
31.3 m
Intercept Depth
30.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:30.1-31.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.1 g/t·m is below.

Negative factors

  • 2.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 8Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
1.2 m
From
30.1 m
To
31.3 m
Intercept Depth
30.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:30.1-31.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 8 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“8”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 10Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
1.2 m
From
30.1 m
To
31.3 m
Intercept Depth
30.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:30.1-31.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 46Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
46
Grade Unit
g/t
Intercept
1.2 m
From
30.1 m
To
31.3 m
Intercept Depth
30.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:30.1-31.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 46 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“46”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.221Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.221
Grade Unit
g/t
Intercept
1.35 m
From
32.25 m
To
33.6 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:32.25-33.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.221 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.221 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.221”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2.3Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.3
Grade Unit
g/t
Intercept
1.35 m
From
32.25 m
To
33.6 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:32.25-33.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.1 g/t·m is below.

Negative factors

  • 2.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 7Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
1.35 m
From
32.25 m
To
33.6 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:32.25-33.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 13Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
1.35 m
From
32.25 m
To
33.6 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:32.25-33.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 62Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
62
Grade Unit
g/t
Intercept
1.35 m
From
32.25 m
To
33.6 m
Intercept Depth
32.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:32.25-33.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 62 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“62”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.377Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.377
Grade Unit
g/t
Intercept
1.25 m
From
33.6 m
To
34.85 m
Intercept Depth
33.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:33.6-34.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.377 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.377”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2.5Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.5
Grade Unit
g/t
Intercept
1.25 m
From
33.6 m
To
34.85 m
Intercept Depth
33.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:33.6-34.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.1 g/t·m is below.

Negative factors

  • 2.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.5”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 18Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18
Grade Unit
g/t
Intercept
1.25 m
From
33.6 m
To
34.85 m
Intercept Depth
33.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:33.6-34.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 18 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“18”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 13Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
1.25 m
From
33.6 m
To
34.85 m
Intercept Depth
33.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:33.6-34.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 127Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
127
Grade Unit
g/t
Intercept
1.25 m
From
33.6 m
To
34.85 m
Intercept Depth
33.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:33.6-34.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.41
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 127 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“127”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.172Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.172
Grade Unit
g/t
Intercept
1.2 m
From
34.85 m
To
36.05 m
Intercept Depth
34.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:34.85-36.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.172 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.172 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.172”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
1.2 m
From
34.85 m
To
36.05 m
Intercept Depth
34.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:34.85-36.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.4 g/t·m is below.

Negative factors

  • 2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 12Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
1.2 m
From
34.85 m
To
36.05 m
Intercept Depth
34.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:34.85-36.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
1.2 m
From
34.85 m
To
36.05 m
Intercept Depth
34.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:34.85-36.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 110Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
110
Grade Unit
g/t
Intercept
1.2 m
From
34.85 m
To
36.05 m
Intercept Depth
34.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:34.85-36.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 110 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“110”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.075Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.075
Grade Unit
g/t
Intercept
0.75 m
From
131.65 m
To
132.4 m
Intercept Depth
131.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:131.65-132.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.075 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.075 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.075”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.6Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.6
Grade Unit
g/t
Intercept
0.75 m
From
131.65 m
To
132.4 m
Intercept Depth
131.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:131.65-132.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.7 g/t·m is below.

Negative factors

  • 3.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 10Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
0.75 m
From
131.65 m
To
132.4 m
Intercept Depth
131.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:131.65-132.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 28Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
28
Grade Unit
g/t
Intercept
0.75 m
From
131.65 m
To
132.4 m
Intercept Depth
131.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:131.65-132.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 28 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“28”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 35Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
35
Grade Unit
g/t
Intercept
0.75 m
From
131.65 m
To
132.4 m
Intercept Depth
131.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:131.65-132.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 35 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“35”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.097Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.097
Grade Unit
g/t
Intercept
0.8 m
From
132.4 m
To
133.2 m
Intercept Depth
132.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:132.4-133.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.097 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.097 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.097”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 10.3Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.3
Grade Unit
g/t
Intercept
0.8 m
From
132.4 m
To
133.2 m
Intercept Depth
132.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:132.4-133.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.2 g/t·m is below.

Negative factors

  • 10.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.8 m
From
132.4 m
To
133.2 m
Intercept Depth
132.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:132.4-133.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 36Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
36
Grade Unit
g/t
Intercept
0.8 m
From
132.4 m
To
133.2 m
Intercept Depth
132.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:132.4-133.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 36 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“36”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 27Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.8 m
From
132.4 m
To
133.2 m
Intercept Depth
132.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:132.4-133.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.137Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.137
Grade Unit
g/t
Intercept
0.5 m
From
133.2 m
To
133.7 m
Intercept Depth
133.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.2-133.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.137 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.137 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.137”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 10.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.6
Grade Unit
g/t
Intercept
0.5 m
From
133.2 m
To
133.7 m
Intercept Depth
133.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.2-133.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.3 g/t·m is below.

Negative factors

  • 10.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.5 m
From
133.2 m
To
133.7 m
Intercept Depth
133.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.2-133.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.5 m
From
133.2 m
To
133.7 m
Intercept Depth
133.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.2-133.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 93Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
93
Grade Unit
g/t
Intercept
0.5 m
From
133.2 m
To
133.7 m
Intercept Depth
133.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.2-133.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 93 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“93”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.86Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.86
Grade Unit
g/t
Intercept
0.65 m
From
133.7 m
To
134.35 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.7-134.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.97
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.86 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.86”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 78Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
78
Grade Unit
g/t
Intercept
0.65 m
From
133.7 m
To
134.35 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.7-134.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.97
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 78 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 50.7 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“78”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 8Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
0.65 m
From
133.7 m
To
134.35 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.7-134.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.97
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 8 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“8”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.65 m
From
133.7 m
To
134.35 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.7-134.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.97
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 42Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
42
Grade Unit
g/t
Intercept
0.65 m
From
133.7 m
To
134.35 m
Intercept Depth
133.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:133.7-134.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.97
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 42 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“42”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.574Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.574
Grade Unit
g/t
Intercept
0.65 m
From
134.35 m
To
135 m
Intercept Depth
134.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:134.35-135

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.02
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.574 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.574”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 31.4Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31.4
Grade Unit
g/t
Intercept
0.65 m
From
134.35 m
To
135 m
Intercept Depth
134.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:134.35-135

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.02
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 31.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 20.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“31.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.65 m
From
134.35 m
To
135 m
Intercept Depth
134.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:134.35-135

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.02
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 8Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
0.65 m
From
134.35 m
To
135 m
Intercept Depth
134.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:134.35-135

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.02
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 8 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“8”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 37Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
37
Grade Unit
g/t
Intercept
0.65 m
From
134.35 m
To
135 m
Intercept Depth
134.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:134.35-135

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.02
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 37 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“37”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.117Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.117
Grade Unit
g/t
Intercept
0.55 m
From
135 m
To
135.55 m
Intercept Depth
135 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135-135.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.117 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.117 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.117”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2.6Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.6
Grade Unit
g/t
Intercept
0.55 m
From
135 m
To
135.55 m
Intercept Depth
135 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135-135.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.4 g/t·m is below.

Negative factors

  • 2.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
0.55 m
From
135 m
To
135.55 m
Intercept Depth
135 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135-135.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 29Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
29
Grade Unit
g/t
Intercept
0.55 m
From
135 m
To
135.55 m
Intercept Depth
135 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135-135.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 29 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“29”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 63Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
63
Grade Unit
g/t
Intercept
0.55 m
From
135 m
To
135.55 m
Intercept Depth
135 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135-135.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 63 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“63”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.091Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.091
Grade Unit
g/t
Intercept
1.45 m
From
135.55 m
To
137 m
Intercept Depth
135.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135.55-137

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.091 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.091 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.091”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2.9Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
1.45 m
From
135.55 m
To
137 m
Intercept Depth
135.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135.55-137

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.2 g/t·m is below.

Negative factors

  • 2.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.9”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
1.45 m
From
135.55 m
To
137 m
Intercept Depth
135.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135.55-137

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 23Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
1.45 m
From
135.55 m
To
137 m
Intercept Depth
135.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135.55-137

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 54Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
54
Grade Unit
g/t
Intercept
1.45 m
From
135.55 m
To
137 m
Intercept Depth
135.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:135.55-137

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 54 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“54”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.086Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.086
Grade Unit
g/t
Intercept
2 m
From
137 m
To
139 m
Intercept Depth
137 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:137-139

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.086 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.086 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.086”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.7Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.7
Grade Unit
g/t
Intercept
2 m
From
137 m
To
139 m
Intercept Depth
137 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:137-139

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.4 g/t·m is below.

Negative factors

  • 3.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
2 m
From
137 m
To
139 m
Intercept Depth
137 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:137-139

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
2 m
From
137 m
To
139 m
Intercept Depth
137 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:137-139

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 57Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
57
Grade Unit
g/t
Intercept
2 m
From
137 m
To
139 m
Intercept Depth
137 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:137-139

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 57 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“57”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.115Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.115
Grade Unit
g/t
Intercept
1.3 m
From
139 m
To
140.3 m
Intercept Depth
139 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:139-140.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.115 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.115 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.115”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.5Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.5
Grade Unit
g/t
Intercept
1.3 m
From
139 m
To
140.3 m
Intercept Depth
139 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:139-140.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.5 g/t·m is below.

Negative factors

  • 3.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.5”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 7Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
1.3 m
From
139 m
To
140.3 m
Intercept Depth
139 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:139-140.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 26Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
1.3 m
From
139 m
To
140.3 m
Intercept Depth
139 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:139-140.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 60Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
60
Grade Unit
g/t
Intercept
1.3 m
From
139 m
To
140.3 m
Intercept Depth
139 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:139-140.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 60 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“60”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.106Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.106
Grade Unit
g/t
Intercept
1.25 m
From
140.3 m
To
141.55 m
Intercept Depth
140.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:140.3-141.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.106 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.106 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.106”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.3Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.3
Grade Unit
g/t
Intercept
1.25 m
From
140.3 m
To
141.55 m
Intercept Depth
140.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:140.3-141.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.1 g/t·m is below.

Negative factors

  • 3.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 97Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
97
Grade Unit
g/t
Intercept
1.25 m
From
140.3 m
To
141.55 m
Intercept Depth
140.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:140.3-141.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 97 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“97”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
1.25 m
From
140.3 m
To
141.55 m
Intercept Depth
140.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:140.3-141.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 128Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
128
Grade Unit
g/t
Intercept
1.25 m
From
140.3 m
To
141.55 m
Intercept Depth
140.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:140.3-141.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 128 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“128”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.073Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.073
Grade Unit
g/t
Intercept
1.2 m
From
141.55 m
To
142.75 m
Intercept Depth
141.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:141.55-142.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.073 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.073 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.073”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 4.6Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.6
Grade Unit
g/t
Intercept
1.2 m
From
141.55 m
To
142.75 m
Intercept Depth
141.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:141.55-142.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.5 g/t·m is below.

Negative factors

  • 4.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 59Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
59
Grade Unit
g/t
Intercept
1.2 m
From
141.55 m
To
142.75 m
Intercept Depth
141.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:141.55-142.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 59 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“59”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 10Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
1.2 m
From
141.55 m
To
142.75 m
Intercept Depth
141.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:141.55-142.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 87Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
87
Grade Unit
g/t
Intercept
1.2 m
From
141.55 m
To
142.75 m
Intercept Depth
141.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:141.55-142.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 87 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“87”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.933Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.933
Grade Unit
g/t
Intercept
0.85 m
From
142.75 m
To
143.6 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:142.75-143.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.933 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.933”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 23.9Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23.9
Grade Unit
g/t
Intercept
0.85 m
From
142.75 m
To
143.6 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:142.75-143.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 23.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 20.3 g/t·m is below.

Negative factors

  • 23.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“23.9”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.85 m
From
142.75 m
To
143.6 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:142.75-143.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 14Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
0.85 m
From
142.75 m
To
143.6 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:142.75-143.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 68Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
68
Grade Unit
g/t
Intercept
0.85 m
From
142.75 m
To
143.6 m
Intercept Depth
142.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:142.75-143.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 68 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“68”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 41Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
41
Grade Unit
g/t
Intercept
0.5 m
From
143.6 m
To
144.1 m
Intercept Depth
143.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:143.6-144.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
71.93
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 41 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“41”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 70Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
70
Grade Unit
g/t
Intercept
0.5 m
From
143.6 m
To
144.1 m
Intercept Depth
143.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:143.6-144.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
71.93
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 70 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“70”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 148Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
148
Grade Unit
g/t
Intercept
0.5 m
From
143.6 m
To
144.1 m
Intercept Depth
143.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:143.6-144.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
71.93
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 148 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“148”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.362Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.362
Grade Unit
g/t
Intercept
0.5 m
From
144.1 m
To
144.6 m
Intercept Depth
144.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.1-144.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.51
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.362 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.362”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 10.7Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.7
Grade Unit
g/t
Intercept
0.5 m
From
144.1 m
To
144.6 m
Intercept Depth
144.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.1-144.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.51
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.3 g/t·m is below.

Negative factors

  • 10.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.5 m
From
144.1 m
To
144.6 m
Intercept Depth
144.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.1-144.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.51
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 18Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18
Grade Unit
g/t
Intercept
0.5 m
From
144.1 m
To
144.6 m
Intercept Depth
144.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.1-144.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.51
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 18 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“18”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 96Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
96
Grade Unit
g/t
Intercept
0.5 m
From
144.1 m
To
144.6 m
Intercept Depth
144.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.1-144.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.51
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 96 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“96”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.099Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.099
Grade Unit
g/t
Intercept
1.4 m
From
144.6 m
To
146 m
Intercept Depth
144.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.6-146

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.099 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.099 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.099”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 1.7Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.7
Grade Unit
g/t
Intercept
1.4 m
From
144.6 m
To
146 m
Intercept Depth
144.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.6-146

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.4 g/t·m is below.

Negative factors

  • 1.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 2Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
1.4 m
From
144.6 m
To
146 m
Intercept Depth
144.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.6-146

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
1.4 m
From
144.6 m
To
146 m
Intercept Depth
144.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.6-146

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 78Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
78
Grade Unit
g/t
Intercept
1.4 m
From
144.6 m
To
146 m
Intercept Depth
144.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:144.6-146

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 78 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“78”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.24Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.24
Grade Unit
g/t
Intercept
2 m
From
146 m
To
148 m
Intercept Depth
146 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:146-148

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below.

Negative factors

  • 0.24 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.24”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2.4Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.4
Grade Unit
g/t
Intercept
2 m
From
146 m
To
148 m
Intercept Depth
146 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:146-148

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.8 g/t·m is below.

Negative factors

  • 2.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 2Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
2 m
From
146 m
To
148 m
Intercept Depth
146 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:146-148

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
2 m
From
146 m
To
148 m
Intercept Depth
146 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:146-148

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 61Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
61
Grade Unit
g/t
Intercept
2 m
From
146 m
To
148 m
Intercept Depth
146 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:146-148

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.27
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 61 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“61”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.071Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.071
Grade Unit
g/t
Intercept
1.4 m
From
148 m
To
149.4 m
Intercept Depth
148 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:148-149.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.071 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.071 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.071”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.4Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.4
Grade Unit
g/t
Intercept
1.4 m
From
148 m
To
149.4 m
Intercept Depth
148 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:148-149.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.8 g/t·m is below.

Negative factors

  • 3.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 2Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
1.4 m
From
148 m
To
149.4 m
Intercept Depth
148 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:148-149.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
1.4 m
From
148 m
To
149.4 m
Intercept Depth
148 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:148-149.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 96Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
96
Grade Unit
g/t
Intercept
1.4 m
From
148 m
To
149.4 m
Intercept Depth
148 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:148-149.4

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 96 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“96”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.316Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.316
Grade Unit
g/t
Intercept
0.85 m
From
149.4 m
To
150.25 m
Intercept Depth
149.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:149.4-150.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.316 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.316”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 19.7Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19.7
Grade Unit
g/t
Intercept
0.85 m
From
149.4 m
To
150.25 m
Intercept Depth
149.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:149.4-150.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 19.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.7 g/t·m is below.

Negative factors

  • 19.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19.7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.85 m
From
149.4 m
To
150.25 m
Intercept Depth
149.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:149.4-150.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 14Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
0.85 m
From
149.4 m
To
150.25 m
Intercept Depth
149.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:149.4-150.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 45Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
45
Grade Unit
g/t
Intercept
0.85 m
From
149.4 m
To
150.25 m
Intercept Depth
149.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:149.4-150.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 45 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“45”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.085Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.085
Grade Unit
g/t
Intercept
0.65 m
From
150.25 m
To
150.9 m
Intercept Depth
150.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:150.25-150.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.085 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.085 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.085”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
0.65 m
From
150.25 m
To
150.9 m
Intercept Depth
150.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:150.25-150.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 5.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.1”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.65 m
From
150.25 m
To
150.9 m
Intercept Depth
150.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:150.25-150.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 17Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
17
Grade Unit
g/t
Intercept
0.65 m
From
150.25 m
To
150.9 m
Intercept Depth
150.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:150.25-150.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 17 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“17”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 43Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
43
Grade Unit
g/t
Intercept
0.65 m
From
150.25 m
To
150.9 m
Intercept Depth
150.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:150.25-150.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 43 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“43”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.079Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.079
Grade Unit
g/t
Intercept
0.8 m
From
152 m
To
152.8 m
Intercept Depth
152 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:152-152.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.079 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.079 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.079”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 2Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
0.8 m
From
152 m
To
152.8 m
Intercept Depth
152 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:152-152.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.6 g/t·m is below.

Negative factors

  • 2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.8 m
From
152 m
To
152.8 m
Intercept Depth
152 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:152-152.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 15Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
0.8 m
From
152 m
To
152.8 m
Intercept Depth
152 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:152-152.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 73Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
73
Grade Unit
g/t
Intercept
0.8 m
From
152 m
To
152.8 m
Intercept Depth
152 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:152-152.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 73 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“73”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
0.5 m
From
175.25 m
To
175.75 m
Intercept Depth
175.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:175.25-175.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.19 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.19”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 1.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.2
Grade Unit
g/t
Intercept
0.5 m
From
175.25 m
To
175.75 m
Intercept Depth
175.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:175.25-175.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.6 g/t·m is below.

Negative factors

  • 1.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 8Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
0.5 m
From
175.25 m
To
175.75 m
Intercept Depth
175.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:175.25-175.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 8 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“8”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 29Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
29
Grade Unit
g/t
Intercept
0.5 m
From
175.25 m
To
175.75 m
Intercept Depth
175.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:175.25-175.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 29 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“29”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 59Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
59
Grade Unit
g/t
Intercept
0.5 m
From
175.25 m
To
175.75 m
Intercept Depth
175.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:175.25-175.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.21
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 59 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“59”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.022Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.022
Grade Unit
g/t
Intercept
0.85 m
From
182 m
To
182.85 m
Intercept Depth
182 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:182-182.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.022 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.022 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.022”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 7.4Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.4
Grade Unit
g/t
Intercept
0.85 m
From
182 m
To
182.85 m
Intercept Depth
182 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:182-182.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.3 g/t·m is below.

Negative factors

  • 7.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 10Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
0.85 m
From
182 m
To
182.85 m
Intercept Depth
182 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:182-182.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 92Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
92
Grade Unit
g/t
Intercept
0.85 m
From
182 m
To
182.85 m
Intercept Depth
182 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:182-182.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 92 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“92”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 176Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
176
Grade Unit
g/t
Intercept
0.85 m
From
182 m
To
182.85 m
Intercept Depth
182 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:182-182.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 176 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“176”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.056Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.056
Grade Unit
g/t
Intercept
0.6 m
From
183.75 m
To
184.35 m
Intercept Depth
183.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:183.75-184.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.056 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.056 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.056”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 3.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.4
Grade Unit
g/t
Intercept
0.6 m
From
183.75 m
To
184.35 m
Intercept Depth
183.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:183.75-184.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.0 g/t·m is below.

Negative factors

  • 3.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.6 m
From
183.75 m
To
184.35 m
Intercept Depth
183.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:183.75-184.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 31Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
0.6 m
From
183.75 m
To
184.35 m
Intercept Depth
183.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:183.75-184.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 91Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
91
Grade Unit
g/t
Intercept
0.6 m
From
183.75 m
To
184.35 m
Intercept Depth
183.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:183.75-184.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 91 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“91”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.113Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.113
Grade Unit
g/t
Intercept
0.9 m
From
230.45 m
To
231.35 m
Intercept Depth
230.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:230.45-231.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.113 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.113 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.113”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 6.2Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.2
Grade Unit
g/t
Intercept
0.9 m
From
230.45 m
To
231.35 m
Intercept Depth
230.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:230.45-231.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.6 g/t·m is below.

Negative factors

  • 6.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.2”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 83Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
83
Grade Unit
g/t
Intercept
0.9 m
From
230.45 m
To
231.35 m
Intercept Depth
230.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:230.45-231.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 83 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“83”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 45Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
45
Grade Unit
g/t
Intercept
0.9 m
From
230.45 m
To
231.35 m
Intercept Depth
230.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:230.45-231.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 45 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“45”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 49Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
49
Grade Unit
g/t
Intercept
0.9 m
From
230.45 m
To
231.35 m
Intercept Depth
230.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:230.45-231.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 49 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“49”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.091Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.091
Grade Unit
g/t
Intercept
0.9 m
From
328.75 m
To
329.65 m
Intercept Depth
328.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:328.75-329.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.091 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.091 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.091”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 36.3Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
36.3
Grade Unit
g/t
Intercept
0.9 m
From
328.75 m
To
329.65 m
Intercept Depth
328.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:328.75-329.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 36.3 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 32.7 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“36.3”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 44Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
44
Grade Unit
g/t
Intercept
0.9 m
From
328.75 m
To
329.65 m
Intercept Depth
328.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:328.75-329.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 44 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“44”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 220Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
220
Grade Unit
g/t
Intercept
0.9 m
From
328.75 m
To
329.65 m
Intercept Depth
328.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:328.75-329.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 220 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“220”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 221Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
221
Grade Unit
g/t
Intercept
0.9 m
From
328.75 m
To
329.65 m
Intercept Depth
328.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:328.75-329.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.61
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 221 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“221”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.031Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.031
Grade Unit
g/t
Intercept
1 m
From
329.65 m
To
330.65 m
Intercept Depth
329.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:329.65-330.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.031 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.031 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.031”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 11.9Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.9
Grade Unit
g/t
Intercept
1 m
From
329.65 m
To
330.65 m
Intercept Depth
329.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:329.65-330.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 11.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.9 g/t·m is below.

Negative factors

  • 11.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“11.9”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 29Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
29
Grade Unit
g/t
Intercept
1 m
From
329.65 m
To
330.65 m
Intercept Depth
329.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:329.65-330.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 29 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“29”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 714Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
714
Grade Unit
g/t
Intercept
1 m
From
329.65 m
To
330.65 m
Intercept Depth
329.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:329.65-330.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 714 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“714”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 336Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
336
Grade Unit
g/t
Intercept
1 m
From
329.65 m
To
330.65 m
Intercept Depth
329.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:329.65-330.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.2
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 336 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“336”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.011Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.011
Grade Unit
g/t
Intercept
0.55 m
From
335.15 m
To
335.7 m
Intercept Depth
335.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:335.15-335.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.011 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.011 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.011”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 6.6Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.6
Grade Unit
g/t
Intercept
0.55 m
From
335.15 m
To
335.7 m
Intercept Depth
335.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:335.15-335.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 6.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.6”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 31Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
0.55 m
From
335.15 m
To
335.7 m
Intercept Depth
335.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:335.15-335.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 155Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
155
Grade Unit
g/t
Intercept
0.55 m
From
335.15 m
To
335.7 m
Intercept Depth
335.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:335.15-335.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 155 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“155”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 335Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
335
Grade Unit
g/t
Intercept
0.55 m
From
335.15 m
To
335.7 m
Intercept Depth
335.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:335.15-335.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 335 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“335”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.026Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.026
Grade Unit
g/t
Intercept
1.05 m
From
346.5 m
To
347.55 m
Intercept Depth
346.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:346.5-347.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.026 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.026 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.026”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 22.4Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
22.4
Grade Unit
g/t
Intercept
1.05 m
From
346.5 m
To
347.55 m
Intercept Depth
346.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:346.5-347.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 22.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 23.5 g/t·m is below.

Negative factors

  • 22.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“22.4”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 26Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
1.05 m
From
346.5 m
To
347.55 m
Intercept Depth
346.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:346.5-347.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 234Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
234
Grade Unit
g/t
Intercept
1.05 m
From
346.5 m
To
347.55 m
Intercept Depth
346.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:346.5-347.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 234 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“234”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 132Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
132
Grade Unit
g/t
Intercept
1.05 m
From
346.5 m
To
347.55 m
Intercept Depth
346.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:346.5-347.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.35
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 132 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“132”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · goldGrade: 0.025Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.025
Grade Unit
g/t
Intercept
0.8 m
From
347.55 m
To
348.35 m
Intercept Depth
347.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:347.55-348.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.025 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.025 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.025”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · silverGrade: 7Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.8 m
From
347.55 m
To
348.35 m
Intercept Depth
347.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:347.55-348.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.6 g/t·m is below.

Negative factors

  • 7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · copperGrade: 40Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40
Grade Unit
g/t
Intercept
0.8 m
From
347.55 m
To
348.35 m
Intercept Depth
347.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:347.55-348.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 40 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“40”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · leadGrade: 257Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
257
Grade Unit
g/t
Intercept
0.8 m
From
347.55 m
To
348.35 m
Intercept Depth
347.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:347.55-348.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 257 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“257”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-54Copalquin · zincGrade: 132Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-54
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
132
Grade Unit
g/t
Intercept
0.8 m
From
347.55 m
To
348.35 m
Intercept Depth
347.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-54:347.55-348.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 132 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“132”

Context: MTH-RE25-54

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · copperGrade: 36Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
36
Grade Unit
g/t
Intercept
0.95 m
From
441.75 m
To
442.7 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:441.75-442.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 36 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“36”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · leadGrade: 32Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
32
Grade Unit
g/t
Intercept
0.95 m
From
441.75 m
To
442.7 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:441.75-442.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 32 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“32”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · zincGrade: 69Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
69
Grade Unit
g/t
Intercept
0.95 m
From
441.75 m
To
442.7 m
Intercept Depth
441.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:441.75-442.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.64
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 69 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“69”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · goldGrade: 1.11Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.11
Grade Unit
g/t
Intercept
1 m
From
444.7 m
To
445.7 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:444.7-445.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.11 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.1 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.11”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · silverGrade: 9.6Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.6
Grade Unit
g/t
Intercept
1 m
From
444.7 m
To
445.7 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:444.7-445.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 9.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 9.6 g/t·m is below.

Negative factors

  • 9.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.6”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · copperGrade: 253Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
253
Grade Unit
g/t
Intercept
1 m
From
444.7 m
To
445.7 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:444.7-445.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 253 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“253”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · leadGrade: 843Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
843
Grade Unit
g/t
Intercept
1 m
From
444.7 m
To
445.7 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:444.7-445.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 843 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“843”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · zincGrade: 1010Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1010
Grade Unit
g/t
Intercept
1 m
From
444.7 m
To
445.7 m
Intercept Depth
444.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:444.7-445.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1010 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“1010”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · goldGrade: 1.305Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.305
Grade Unit
g/t
Intercept
0.5 m
From
445.7 m
To
446.2 m
Intercept Depth
445.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:445.7-446.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.88
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.305 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.305”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · silverGrade: 110Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
110
Grade Unit
g/t
Intercept
0.5 m
From
445.7 m
To
446.2 m
Intercept Depth
445.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:445.7-446.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.88
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 110 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 55.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“110”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · copperGrade: 1130Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1130
Grade Unit
g/t
Intercept
0.5 m
From
445.7 m
To
446.2 m
Intercept Depth
445.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:445.7-446.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.88
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1130 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“1130”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · leadGrade: 3490Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3490
Grade Unit
g/t
Intercept
0.5 m
From
445.7 m
To
446.2 m
Intercept Depth
445.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:445.7-446.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.88
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3490 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“3490”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · zincGrade: 3880Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3880
Grade Unit
g/t
Intercept
0.5 m
From
445.7 m
To
446.2 m
Intercept Depth
445.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:445.7-446.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.88
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3880 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“3880”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · goldGrade: 1.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.2
Grade Unit
g/t
Intercept
0.5 m
From
446.2 m
To
446.7 m
Intercept Depth
446.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.2-446.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.49
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.2”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · silverGrade: 90.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
90.4
Grade Unit
g/t
Intercept
0.5 m
From
446.2 m
To
446.7 m
Intercept Depth
446.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.2-446.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.49
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 90.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 45.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“90.4”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · copperGrade: 174Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
174
Grade Unit
g/t
Intercept
0.5 m
From
446.2 m
To
446.7 m
Intercept Depth
446.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.2-446.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.49
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 174 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“174”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · leadGrade: 1360Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1360
Grade Unit
g/t
Intercept
0.5 m
From
446.2 m
To
446.7 m
Intercept Depth
446.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.2-446.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.49
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1360 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“1360”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · zincGrade: 1570Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1570
Grade Unit
g/t
Intercept
0.5 m
From
446.2 m
To
446.7 m
Intercept Depth
446.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.2-446.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.49
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1570 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“1570”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · goldGrade: 1.59Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.59
Grade Unit
g/t
Intercept
0.5 m
From
446.7 m
To
447.2 m
Intercept Depth
446.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.7-447.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.59 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.59”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · silverGrade: 91Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
91
Grade Unit
g/t
Intercept
0.5 m
From
446.7 m
To
447.2 m
Intercept Depth
446.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.7-447.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 91 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 45.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“91”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · copperGrade: 215Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
215
Grade Unit
g/t
Intercept
0.5 m
From
446.7 m
To
447.2 m
Intercept Depth
446.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.7-447.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 215 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“215”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · leadGrade: 1045Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1045
Grade Unit
g/t
Intercept
0.5 m
From
446.7 m
To
447.2 m
Intercept Depth
446.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.7-447.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1045 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“1045”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · zincGrade: 1755Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1755
Grade Unit
g/t
Intercept
0.5 m
From
446.7 m
To
447.2 m
Intercept Depth
446.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:446.7-447.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.89
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1755 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“1755”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · goldGrade: 0.084Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.084
Grade Unit
g/t
Intercept
1 m
From
456.5 m
To
457.5 m
Intercept Depth
456.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:456.5-457.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.084 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.084 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.084”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · silverGrade: 2.3Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.3
Grade Unit
g/t
Intercept
1 m
From
456.5 m
To
457.5 m
Intercept Depth
456.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:456.5-457.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.3 g/t·m is below.

Negative factors

  • 2.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.3”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · copperGrade: 21Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
1 m
From
456.5 m
To
457.5 m
Intercept Depth
456.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:456.5-457.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
1 m
From
456.5 m
To
457.5 m
Intercept Depth
456.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:456.5-457.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-56Copalquin · zincGrade: 118Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-56
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
118
Grade Unit
g/t
Intercept
1 m
From
456.5 m
To
457.5 m
Intercept Depth
456.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-56:456.5-457.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 118 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“118”

Context: MTH-RE25-56

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · goldGrade: 0.031Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.031
Grade Unit
g/t
Intercept
1.3 m
From
177.7 m
To
179 m
Intercept Depth
177.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:177.7-179

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.031 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.031 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.031”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · silverGrade: 10.1Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.1
Grade Unit
g/t
Intercept
1.3 m
From
177.7 m
To
179 m
Intercept Depth
177.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:177.7-179

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 13.1 g/t·m is below.

Negative factors

  • 10.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.1”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
1.3 m
From
177.7 m
To
179 m
Intercept Depth
177.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:177.7-179

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 15Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15
Grade Unit
g/t
Intercept
1.3 m
From
177.7 m
To
179 m
Intercept Depth
177.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:177.7-179

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 15 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“15”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 52Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
52
Grade Unit
g/t
Intercept
1.3 m
From
177.7 m
To
179 m
Intercept Depth
177.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:177.7-179

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 52 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“52”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · goldGrade: 0.044Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.044
Grade Unit
g/t
Intercept
1 m
From
179 m
To
180 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:179-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.044 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.044 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.044”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
1 m
From
179 m
To
180 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:179-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.1 g/t·m is below.

Negative factors

  • 5.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.1”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
1 m
From
179 m
To
180 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:179-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 20Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20
Grade Unit
g/t
Intercept
1 m
From
179 m
To
180 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:179-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 20 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“20”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 46Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
46
Grade Unit
g/t
Intercept
1 m
From
179 m
To
180 m
Intercept Depth
179 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:179-180

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 46 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“46”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 45Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
45
Grade Unit
g/t
Intercept
0.5 m
From
189.15 m
To
189.65 m
Intercept Depth
189.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:189.15-189.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 45 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“45”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 25Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
0.5 m
From
189.15 m
To
189.65 m
Intercept Depth
189.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:189.15-189.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 112Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
112
Grade Unit
g/t
Intercept
0.5 m
From
189.15 m
To
189.65 m
Intercept Depth
189.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:189.15-189.65

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 112 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“112”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · goldGrade: 0.055Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.055
Grade Unit
g/t
Intercept
1.15 m
From
247.85 m
To
249 m
Intercept Depth
247.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:247.85-249

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.055 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.055 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.055”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · silverGrade: 5.2Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.2
Grade Unit
g/t
Intercept
1.15 m
From
247.85 m
To
249 m
Intercept Depth
247.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:247.85-249

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.0 g/t·m is below.

Negative factors

  • 5.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.2”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
1.15 m
From
247.85 m
To
249 m
Intercept Depth
247.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:247.85-249

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 13Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
1.15 m
From
247.85 m
To
249 m
Intercept Depth
247.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:247.85-249

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 43Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
43
Grade Unit
g/t
Intercept
1.15 m
From
247.85 m
To
249 m
Intercept Depth
247.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:247.85-249

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 43 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“43”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · goldGrade: 0.188Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.188
Grade Unit
g/t
Intercept
0.75 m
From
252.3 m
To
253.05 m
Intercept Depth
252.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:252.3-253.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.188 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.188 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.188”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · silverGrade: 2.9Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
0.75 m
From
252.3 m
To
253.05 m
Intercept Depth
252.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:252.3-253.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.2 g/t·m is below.

Negative factors

  • 2.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.9”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 12Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.75 m
From
252.3 m
To
253.05 m
Intercept Depth
252.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:252.3-253.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 116Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
116
Grade Unit
g/t
Intercept
0.75 m
From
252.3 m
To
253.05 m
Intercept Depth
252.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:252.3-253.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 116 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“116”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 302Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
302
Grade Unit
g/t
Intercept
0.75 m
From
252.3 m
To
253.05 m
Intercept Depth
252.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:252.3-253.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 302 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“302”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · goldGrade: 0.021Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.021
Grade Unit
g/t
Intercept
2 m
From
259 m
To
261 m
Intercept Depth
259 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:259-261

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.021 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.021 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.021”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · silverGrade: 7.8Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.8
Grade Unit
g/t
Intercept
2 m
From
259 m
To
261 m
Intercept Depth
259 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:259-261

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 15.6 g/t·m is below.

Negative factors

  • 7.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.8”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 9Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
2 m
From
259 m
To
261 m
Intercept Depth
259 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:259-261

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 50Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
50
Grade Unit
g/t
Intercept
2 m
From
259 m
To
261 m
Intercept Depth
259 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:259-261

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 50 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“50”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 98Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
98
Grade Unit
g/t
Intercept
2 m
From
259 m
To
261 m
Intercept Depth
259 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:259-261

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 98 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“98”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · goldGrade: 0.574Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.574
Grade Unit
g/t
Intercept
1.05 m
From
334.9 m
To
335.95 m
Intercept Depth
334.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:334.9-335.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.574 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.574”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · silverGrade: 1.6Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.6
Grade Unit
g/t
Intercept
1.05 m
From
334.9 m
To
335.95 m
Intercept Depth
334.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:334.9-335.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.7 g/t·m is below.

Negative factors

  • 1.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.6”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
1.05 m
From
334.9 m
To
335.95 m
Intercept Depth
334.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:334.9-335.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · leadGrade: 10Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
1.05 m
From
334.9 m
To
335.95 m
Intercept Depth
334.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:334.9-335.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-57Copalquin · zincGrade: 68Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-57
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
68
Grade Unit
g/t
Intercept
1.05 m
From
334.9 m
To
335.95 m
Intercept Depth
334.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-57:334.9-335.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.6
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 68 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“68”

Context: MTH-RE25-57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.287Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.287
Grade Unit
g/t
Intercept
0.55 m
From
158.2 m
To
158.75 m
Intercept Depth
158.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.2-158.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.287 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.287 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.287”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 13.4Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13.4
Grade Unit
g/t
Intercept
0.55 m
From
158.2 m
To
158.75 m
Intercept Depth
158.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.2-158.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 13.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.4 g/t·m is below.

Negative factors

  • 13.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.4”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 12Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.55 m
From
158.2 m
To
158.75 m
Intercept Depth
158.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.2-158.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.55 m
From
158.2 m
To
158.75 m
Intercept Depth
158.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.2-158.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 93Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
93
Grade Unit
g/t
Intercept
0.55 m
From
158.2 m
To
158.75 m
Intercept Depth
158.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.2-158.75

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.48
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 93 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“93”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.104Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.104
Grade Unit
g/t
Intercept
0.8 m
From
158.75 m
To
159.55 m
Intercept Depth
158.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.75-159.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.104 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.104 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.104”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 4.3Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.3
Grade Unit
g/t
Intercept
0.8 m
From
158.75 m
To
159.55 m
Intercept Depth
158.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.75-159.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.4 g/t·m is below.

Negative factors

  • 4.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 12Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.8 m
From
158.75 m
To
159.55 m
Intercept Depth
158.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.75-159.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 20Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20
Grade Unit
g/t
Intercept
0.8 m
From
158.75 m
To
159.55 m
Intercept Depth
158.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.75-159.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 20 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“20”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 62Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
62
Grade Unit
g/t
Intercept
0.8 m
From
158.75 m
To
159.55 m
Intercept Depth
158.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:158.75-159.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 62 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“62”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.351Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.351
Grade Unit
g/t
Intercept
0.75 m
From
159.55 m
To
160.3 m
Intercept Depth
159.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:159.55-160.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.62
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.351 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.351”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 19Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.75 m
From
159.55 m
To
160.3 m
Intercept Depth
159.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:159.55-160.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.62
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 19 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.3 g/t·m is below.

Negative factors

  • 19 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“19”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 13Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
0.75 m
From
159.55 m
To
160.3 m
Intercept Depth
159.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:159.55-160.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.62
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.75 m
From
159.55 m
To
160.3 m
Intercept Depth
159.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:159.55-160.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.62
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 90Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
90
Grade Unit
g/t
Intercept
0.75 m
From
159.55 m
To
160.3 m
Intercept Depth
159.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:159.55-160.3

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.62
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 90 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“90”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.082Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.082
Grade Unit
g/t
Intercept
1.15 m
From
160.3 m
To
161.45 m
Intercept Depth
160.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:160.3-161.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.082 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.082 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.082”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 9.6Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.6
Grade Unit
g/t
Intercept
1.15 m
From
160.3 m
To
161.45 m
Intercept Depth
160.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:160.3-161.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 9.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.0 g/t·m is below.

Negative factors

  • 9.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.6”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 2Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2
Grade Unit
g/t
Intercept
1.15 m
From
160.3 m
To
161.45 m
Intercept Depth
160.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:160.3-161.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 2 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“2”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 9Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
1.15 m
From
160.3 m
To
161.45 m
Intercept Depth
160.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:160.3-161.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 105Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
105
Grade Unit
g/t
Intercept
1.15 m
From
160.3 m
To
161.45 m
Intercept Depth
160.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:160.3-161.45

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 105 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“105”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.044Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.044
Grade Unit
g/t
Intercept
0.5 m
From
162 m
To
162.5 m
Intercept Depth
162 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:162-162.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.044 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.044 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.044”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 6.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.6
Grade Unit
g/t
Intercept
0.5 m
From
162 m
To
162.5 m
Intercept Depth
162 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:162-162.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 6.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.6”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 41Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
41
Grade Unit
g/t
Intercept
0.5 m
From
162 m
To
162.5 m
Intercept Depth
162 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:162-162.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 41 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“41”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 23Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
0.5 m
From
162 m
To
162.5 m
Intercept Depth
162 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:162-162.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 87Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
87
Grade Unit
g/t
Intercept
0.5 m
From
162 m
To
162.5 m
Intercept Depth
162 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:162-162.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.14
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 87 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“87”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.094Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.094
Grade Unit
g/t
Intercept
0.85 m
From
163.3 m
To
164.15 m
Intercept Depth
163.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:163.3-164.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.094 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.094 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.094”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 2.7Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.7
Grade Unit
g/t
Intercept
0.85 m
From
163.3 m
To
164.15 m
Intercept Depth
163.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:163.3-164.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.3 g/t·m is below.

Negative factors

  • 2.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.7”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 6Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
0.85 m
From
163.3 m
To
164.15 m
Intercept Depth
163.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:163.3-164.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 6 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“6”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
0.85 m
From
163.3 m
To
164.15 m
Intercept Depth
163.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:163.3-164.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 120Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
120
Grade Unit
g/t
Intercept
0.85 m
From
163.3 m
To
164.15 m
Intercept Depth
163.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:163.3-164.15

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 120 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“120”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.089Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.089
Grade Unit
g/t
Intercept
0.8 m
From
164.15 m
To
164.95 m
Intercept Depth
164.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.15-164.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.089 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.089 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.089”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 6.2Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.2
Grade Unit
g/t
Intercept
0.8 m
From
164.15 m
To
164.95 m
Intercept Depth
164.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.15-164.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.0 g/t·m is below.

Negative factors

  • 6.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.2”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.8 m
From
164.15 m
To
164.95 m
Intercept Depth
164.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.15-164.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 11Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
0.8 m
From
164.15 m
To
164.95 m
Intercept Depth
164.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.15-164.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 11 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“11”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 125Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
125
Grade Unit
g/t
Intercept
0.8 m
From
164.15 m
To
164.95 m
Intercept Depth
164.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.15-164.95

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 125 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“125”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.069Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.069
Grade Unit
g/t
Intercept
0.9 m
From
164.95 m
To
165.85 m
Intercept Depth
164.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.95-165.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.069 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.069 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.069”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 2.3Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.3
Grade Unit
g/t
Intercept
0.9 m
From
164.95 m
To
165.85 m
Intercept Depth
164.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.95-165.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.1 g/t·m is below.

Negative factors

  • 2.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 7Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.9 m
From
164.95 m
To
165.85 m
Intercept Depth
164.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.95-165.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 11Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11
Grade Unit
g/t
Intercept
0.9 m
From
164.95 m
To
165.85 m
Intercept Depth
164.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.95-165.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 11 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“11”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 103Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
103
Grade Unit
g/t
Intercept
0.9 m
From
164.95 m
To
165.85 m
Intercept Depth
164.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:164.95-165.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 103 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“103”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 16Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
0.5 m
From
165.85 m
To
166.35 m
Intercept Depth
165.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:165.85-166.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 23Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
0.5 m
From
165.85 m
To
166.35 m
Intercept Depth
165.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:165.85-166.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 101Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
101
Grade Unit
g/t
Intercept
0.5 m
From
165.85 m
To
166.35 m
Intercept Depth
165.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:165.85-166.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 101 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“101”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.044Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.044
Grade Unit
g/t
Intercept
0.65 m
From
166.35 m
To
167 m
Intercept Depth
166.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:166.35-167

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.044 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.044 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.044”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 5.3Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.3
Grade Unit
g/t
Intercept
0.65 m
From
166.35 m
To
167 m
Intercept Depth
166.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:166.35-167

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.4 g/t·m is below.

Negative factors

  • 5.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.65 m
From
166.35 m
To
167 m
Intercept Depth
166.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:166.35-167

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 10Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
0.65 m
From
166.35 m
To
167 m
Intercept Depth
166.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:166.35-167

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 99Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
99
Grade Unit
g/t
Intercept
0.65 m
From
166.35 m
To
167 m
Intercept Depth
166.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:166.35-167

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 99 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“99”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.093Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.093
Grade Unit
g/t
Intercept
1 m
From
167 m
To
168 m
Intercept Depth
167 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:167-168

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.093 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.093 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.093”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 8.8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.8
Grade Unit
g/t
Intercept
1 m
From
167 m
To
168 m
Intercept Depth
167 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:167-168

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 8.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.8 g/t·m is below.

Negative factors

  • 8.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.8”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
1 m
From
167 m
To
168 m
Intercept Depth
167 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:167-168

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
1 m
From
167 m
To
168 m
Intercept Depth
167 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:167-168

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 98Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
98
Grade Unit
g/t
Intercept
1 m
From
167 m
To
168 m
Intercept Depth
167 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:167-168

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 98 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“98”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.062Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.062
Grade Unit
g/t
Intercept
1.45 m
From
169.55 m
To
171 m
Intercept Depth
169.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:169.55-171

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.062 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.062 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.062”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 3.5Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.5
Grade Unit
g/t
Intercept
1.45 m
From
169.55 m
To
171 m
Intercept Depth
169.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:169.55-171

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.1 g/t·m is below.

Negative factors

  • 3.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.5”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 3Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
1.45 m
From
169.55 m
To
171 m
Intercept Depth
169.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:169.55-171

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 3 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 16Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16
Grade Unit
g/t
Intercept
1.45 m
From
169.55 m
To
171 m
Intercept Depth
169.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:169.55-171

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 16 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“16”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 122Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
122
Grade Unit
g/t
Intercept
1.45 m
From
169.55 m
To
171 m
Intercept Depth
169.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:169.55-171

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 122 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“122”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.224Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.224
Grade Unit
g/t
Intercept
1.15 m
From
174.85 m
To
176 m
Intercept Depth
174.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:174.85-176

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.224 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.224 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.224”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 7.3Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.3
Grade Unit
g/t
Intercept
1.15 m
From
174.85 m
To
176 m
Intercept Depth
174.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:174.85-176

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 7.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 49Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
49
Grade Unit
g/t
Intercept
1.15 m
From
174.85 m
To
176 m
Intercept Depth
174.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:174.85-176

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 49 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“49”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 30Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
30
Grade Unit
g/t
Intercept
1.15 m
From
174.85 m
To
176 m
Intercept Depth
174.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:174.85-176

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 30 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“30”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 160Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
160
Grade Unit
g/t
Intercept
1.15 m
From
174.85 m
To
176 m
Intercept Depth
174.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:174.85-176

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.33
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 160 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“160”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.152Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.152
Grade Unit
g/t
Intercept
2 m
From
184 m
To
186 m
Intercept Depth
184 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:184-186

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.152 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.152 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.152”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 5.3Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.3
Grade Unit
g/t
Intercept
2 m
From
184 m
To
186 m
Intercept Depth
184 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:184-186

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 10.6 g/t·m is below.

Negative factors

  • 5.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 1Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1
Grade Unit
g/t
Intercept
2 m
From
184 m
To
186 m
Intercept Depth
184 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:184-186

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 1 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“1”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 14Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
2 m
From
184 m
To
186 m
Intercept Depth
184 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:184-186

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 83Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
83
Grade Unit
g/t
Intercept
2 m
From
184 m
To
186 m
Intercept Depth
184 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:184-186

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.23
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 83 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“83”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.478Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.478
Grade Unit
g/t
Intercept
2 m
From
186 m
To
188 m
Intercept Depth
186 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:186-188

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.478 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.478”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 15.1Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.1
Grade Unit
g/t
Intercept
2 m
From
186 m
To
188 m
Intercept Depth
186 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:186-188

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 15.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 30.2 g/t·m is below.

Negative factors

  • 15.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.1”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 13Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13
Grade Unit
g/t
Intercept
2 m
From
186 m
To
188 m
Intercept Depth
186 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:186-188

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 13 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“13”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 24Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
2 m
From
186 m
To
188 m
Intercept Depth
186 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:186-188

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 92Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
92
Grade Unit
g/t
Intercept
2 m
From
186 m
To
188 m
Intercept Depth
186 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:186-188

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.69
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 92 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“92”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.178Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.178
Grade Unit
g/t
Intercept
2 m
From
192 m
To
194 m
Intercept Depth
192 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:192-194

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.178 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below.

Negative factors

  • 0.178 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.178”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 4.2Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
2 m
From
192 m
To
194 m
Intercept Depth
192 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:192-194

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 4.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 4.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.2”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 5Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
2 m
From
192 m
To
194 m
Intercept Depth
192 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:192-194

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 5 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“5”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 12Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12
Grade Unit
g/t
Intercept
2 m
From
192 m
To
194 m
Intercept Depth
192 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:192-194

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 12 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“12”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 77Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
77
Grade Unit
g/t
Intercept
2 m
From
192 m
To
194 m
Intercept Depth
192 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:192-194

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.24
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 77 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“77”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.085Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.085
Grade Unit
g/t
Intercept
1.5 m
From
196 m
To
197.5 m
Intercept Depth
196 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:196-197.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.085 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.085 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.085”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 1.2Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.2
Grade Unit
g/t
Intercept
1.5 m
From
196 m
To
197.5 m
Intercept Depth
196 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:196-197.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.8 g/t·m is below.

Negative factors

  • 1.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.2”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 26Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26
Grade Unit
g/t
Intercept
1.5 m
From
196 m
To
197.5 m
Intercept Depth
196 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:196-197.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 26 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“26”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 9Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
1.5 m
From
196 m
To
197.5 m
Intercept Depth
196 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:196-197.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 49Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
49
Grade Unit
g/t
Intercept
1.5 m
From
196 m
To
197.5 m
Intercept Depth
196 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:196-197.5

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.1
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 49 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“49”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.084Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.084
Grade Unit
g/t
Intercept
0.8 m
From
224.3 m
To
225.1 m
Intercept Depth
224.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:224.3-225.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.084 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.084 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.084”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 5Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
0.8 m
From
224.3 m
To
225.1 m
Intercept Depth
224.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:224.3-225.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.0 g/t·m is below.

Negative factors

  • 5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 148Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
148
Grade Unit
g/t
Intercept
0.8 m
From
224.3 m
To
225.1 m
Intercept Depth
224.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:224.3-225.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 148 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“148”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 47Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
47
Grade Unit
g/t
Intercept
0.8 m
From
224.3 m
To
225.1 m
Intercept Depth
224.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:224.3-225.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 47 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“47”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 69Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
69
Grade Unit
g/t
Intercept
0.8 m
From
224.3 m
To
225.1 m
Intercept Depth
224.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:224.3-225.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.16
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 69 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“69”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.102Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.102
Grade Unit
g/t
Intercept
0.65 m
From
243.4 m
To
244.05 m
Intercept Depth
243.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:243.4-244.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.102 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.102 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.102”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 13.5Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13.5
Grade Unit
g/t
Intercept
0.65 m
From
243.4 m
To
244.05 m
Intercept Depth
243.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:243.4-244.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 13.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.8 g/t·m is below.

Negative factors

  • 13.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.5”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 21Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.65 m
From
243.4 m
To
244.05 m
Intercept Depth
243.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:243.4-244.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 31Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
31
Grade Unit
g/t
Intercept
0.65 m
From
243.4 m
To
244.05 m
Intercept Depth
243.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:243.4-244.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 31 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“31”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 70Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
70
Grade Unit
g/t
Intercept
0.65 m
From
243.4 m
To
244.05 m
Intercept Depth
243.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:243.4-244.05

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.29
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 70 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“70”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.07
Grade Unit
g/t
Intercept
0.85 m
From
250.5 m
To
251.35 m
Intercept Depth
250.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:250.5-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 5.8Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
0.85 m
From
250.5 m
To
251.35 m
Intercept Depth
250.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:250.5-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.9 g/t·m is below.

Negative factors

  • 5.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.8”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 50Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
50
Grade Unit
g/t
Intercept
0.85 m
From
250.5 m
To
251.35 m
Intercept Depth
250.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:250.5-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 50 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“50”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
0.85 m
From
250.5 m
To
251.35 m
Intercept Depth
250.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:250.5-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 124Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
124
Grade Unit
g/t
Intercept
0.85 m
From
250.5 m
To
251.35 m
Intercept Depth
250.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:250.5-251.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.15
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 124 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“124”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.038Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.038
Grade Unit
g/t
Intercept
0.8 m
From
262.1 m
To
262.9 m
Intercept Depth
262.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.1-262.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.038 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.038 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.038”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 10.1Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.1
Grade Unit
g/t
Intercept
0.8 m
From
262.1 m
To
262.9 m
Intercept Depth
262.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.1-262.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.1 g/t·m is below.

Negative factors

  • 10.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.1”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 36Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
36
Grade Unit
g/t
Intercept
0.8 m
From
262.1 m
To
262.9 m
Intercept Depth
262.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.1-262.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 36 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“36”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 45Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
45
Grade Unit
g/t
Intercept
0.8 m
From
262.1 m
To
262.9 m
Intercept Depth
262.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.1-262.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 45 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“45”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 99Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
99
Grade Unit
g/t
Intercept
0.8 m
From
262.1 m
To
262.9 m
Intercept Depth
262.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.1-262.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 99 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“99”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.051Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.051
Grade Unit
g/t
Intercept
0.8 m
From
262.9 m
To
263.7 m
Intercept Depth
262.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.9-263.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.051 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.051 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.051”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 14.8Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14.8
Grade Unit
g/t
Intercept
0.8 m
From
262.9 m
To
263.7 m
Intercept Depth
262.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.9-263.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 14.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.8 g/t·m is below.

Negative factors

  • 14.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.8”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 21Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.8 m
From
262.9 m
To
263.7 m
Intercept Depth
262.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.9-263.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 43Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
43
Grade Unit
g/t
Intercept
0.8 m
From
262.9 m
To
263.7 m
Intercept Depth
262.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.9-263.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 43 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“43”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 40Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40
Grade Unit
g/t
Intercept
0.8 m
From
262.9 m
To
263.7 m
Intercept Depth
262.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:262.9-263.7

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.26
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 40 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“40”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.03Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
1.2 m
From
263.7 m
To
264.9 m
Intercept Depth
263.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:263.7-264.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 10.3Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.3
Grade Unit
g/t
Intercept
1.2 m
From
263.7 m
To
264.9 m
Intercept Depth
263.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:263.7-264.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 10.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 12.4 g/t·m is below.

Negative factors

  • 10.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 10Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10
Grade Unit
g/t
Intercept
1.2 m
From
263.7 m
To
264.9 m
Intercept Depth
263.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:263.7-264.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 10 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“10”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 32Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
32
Grade Unit
g/t
Intercept
1.2 m
From
263.7 m
To
264.9 m
Intercept Depth
263.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:263.7-264.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 32 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“32”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 25Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25
Grade Unit
g/t
Intercept
1.2 m
From
263.7 m
To
264.9 m
Intercept Depth
263.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:263.7-264.9

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 25 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“25”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.206Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.206
Grade Unit
g/t
Intercept
0.7 m
From
268.5 m
To
269.2 m
Intercept Depth
268.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:268.5-269.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.206 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.206 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.206”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 7.6Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.6
Grade Unit
g/t
Intercept
0.7 m
From
268.5 m
To
269.2 m
Intercept Depth
268.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:268.5-269.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 7.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.3 g/t·m is below.

Negative factors

  • 7.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.6”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 27Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27
Grade Unit
g/t
Intercept
0.7 m
From
268.5 m
To
269.2 m
Intercept Depth
268.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:268.5-269.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 27 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“27”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 39Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39
Grade Unit
g/t
Intercept
0.7 m
From
268.5 m
To
269.2 m
Intercept Depth
268.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:268.5-269.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 39 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“39”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 106Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
106
Grade Unit
g/t
Intercept
0.7 m
From
268.5 m
To
269.2 m
Intercept Depth
268.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:268.5-269.2

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.31
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 106 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“106”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.2Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
1.05 m
From
269.2 m
To
270.25 m
Intercept Depth
269.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:269.2-270.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.2 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.2”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 15.8Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.8
Grade Unit
g/t
Intercept
1.05 m
From
269.2 m
To
270.25 m
Intercept Depth
269.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:269.2-270.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 15.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.6 g/t·m is below.

Negative factors

  • 15.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.8”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 62Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
62
Grade Unit
g/t
Intercept
1.05 m
From
269.2 m
To
270.25 m
Intercept Depth
269.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:269.2-270.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 62 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“62”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 187Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
187
Grade Unit
g/t
Intercept
1.05 m
From
269.2 m
To
270.25 m
Intercept Depth
269.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:269.2-270.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 187 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“187”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 408Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
408
Grade Unit
g/t
Intercept
1.05 m
From
269.2 m
To
270.25 m
Intercept Depth
269.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:269.2-270.25

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.43
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 408 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“408”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.073Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.073
Grade Unit
g/t
Intercept
1.4 m
From
280.7 m
To
282.1 m
Intercept Depth
280.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:280.7-282.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.073 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.073 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.073”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 3Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3
Grade Unit
g/t
Intercept
1.4 m
From
280.7 m
To
282.1 m
Intercept Depth
280.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:280.7-282.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.2 g/t·m is below.

Negative factors

  • 3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 24Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
24
Grade Unit
g/t
Intercept
1.4 m
From
280.7 m
To
282.1 m
Intercept Depth
280.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:280.7-282.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 24 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“24”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 19Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
19
Grade Unit
g/t
Intercept
1.4 m
From
280.7 m
To
282.1 m
Intercept Depth
280.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:280.7-282.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 19 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“19”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 148Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
148
Grade Unit
g/t
Intercept
1.4 m
From
280.7 m
To
282.1 m
Intercept Depth
280.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:280.7-282.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.12
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 148 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“148”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.093Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.093
Grade Unit
g/t
Intercept
1.55 m
From
283.55 m
To
285.1 m
Intercept Depth
283.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:283.55-285.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.093 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.093 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.093”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 5.4Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.4
Grade Unit
g/t
Intercept
1.55 m
From
283.55 m
To
285.1 m
Intercept Depth
283.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:283.55-285.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.4 g/t·m is below.

Negative factors

  • 5.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.4”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 79Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
79
Grade Unit
g/t
Intercept
1.55 m
From
283.55 m
To
285.1 m
Intercept Depth
283.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:283.55-285.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 79 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“79”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 108Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
108
Grade Unit
g/t
Intercept
1.55 m
From
283.55 m
To
285.1 m
Intercept Depth
283.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:283.55-285.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 108 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“108”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 227Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
227
Grade Unit
g/t
Intercept
1.55 m
From
283.55 m
To
285.1 m
Intercept Depth
283.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:283.55-285.1

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.17
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 227 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“227”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.059Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.059
Grade Unit
g/t
Intercept
0.5 m
From
285.1 m
To
285.6 m
Intercept Depth
285.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.1-285.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.059 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.059 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.059”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 3.3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.3
Grade Unit
g/t
Intercept
0.5 m
From
285.1 m
To
285.6 m
Intercept Depth
285.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.1-285.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.6 g/t·m is below.

Negative factors

  • 3.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
0.5 m
From
285.1 m
To
285.6 m
Intercept Depth
285.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.1-285.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 6 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“6”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.5 m
From
285.1 m
To
285.6 m
Intercept Depth
285.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.1-285.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 69Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
69
Grade Unit
g/t
Intercept
0.5 m
From
285.1 m
To
285.6 m
Intercept Depth
285.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.1-285.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 69 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“69”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.084Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.084
Grade Unit
g/t
Intercept
0.75 m
From
285.6 m
To
286.35 m
Intercept Depth
285.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.6-286.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.084 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.084 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.084”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 3.3Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.3
Grade Unit
g/t
Intercept
0.75 m
From
285.6 m
To
286.35 m
Intercept Depth
285.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.6-286.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.5 g/t·m is below.

Negative factors

  • 3.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.3”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 4Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.75 m
From
285.6 m
To
286.35 m
Intercept Depth
285.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.6-286.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 4 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“4”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 21Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21
Grade Unit
g/t
Intercept
0.75 m
From
285.6 m
To
286.35 m
Intercept Depth
285.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.6-286.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 21 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“21”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 23Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
23
Grade Unit
g/t
Intercept
0.75 m
From
285.6 m
To
286.35 m
Intercept Depth
285.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:285.6-286.35

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 23 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“23”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · goldGrade: 0.181Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.181
Grade Unit
g/t
Intercept
1.2 m
From
286.35 m
To
287.55 m
Intercept Depth
286.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:286.35-287.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.181 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.181 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.181”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · silverGrade: 5Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
1.2 m
From
286.35 m
To
287.55 m
Intercept Depth
286.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:286.35-287.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.0 g/t·m is below.

Negative factors

  • 5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · copperGrade: 41Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
41
Grade Unit
g/t
Intercept
1.2 m
From
286.35 m
To
287.55 m
Intercept Depth
286.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:286.35-287.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 41 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“41”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · leadGrade: 58Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
58
Grade Unit
g/t
Intercept
1.2 m
From
286.35 m
To
287.55 m
Intercept Depth
286.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:286.35-287.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 58 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“58”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-58Copalquin · zincGrade: 240Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-58
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
240
Grade Unit
g/t
Intercept
1.2 m
From
286.35 m
To
287.55 m
Intercept Depth
286.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-58:286.35-287.55

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.25
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 240 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“240”

Context: MTH-RE25-58

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · goldGrade: 0.031Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.031
Grade Unit
g/t
Intercept
0.95 m
From
417.9 m
To
418.85 m
Intercept Depth
417.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:417.9-418.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.031 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.031 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.031”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · silverGrade: 5.7Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.7
Grade Unit
g/t
Intercept
0.95 m
From
417.9 m
To
418.85 m
Intercept Depth
417.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:417.9-418.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 5.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.4 g/t·m is below.

Negative factors

  • 5.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.7”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · copperGrade: 9Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
0.95 m
From
417.9 m
To
418.85 m
Intercept Depth
417.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:417.9-418.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 9 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“9”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · leadGrade: 7Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.95 m
From
417.9 m
To
418.85 m
Intercept Depth
417.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:417.9-418.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · zincGrade: 7Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.95 m
From
417.9 m
To
418.85 m
Intercept Depth
417.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:417.9-418.85

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.11
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · goldGrade: 0.031Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.031
Grade Unit
g/t
Intercept
0.95 m
From
418.85 m
To
419.8 m
Intercept Depth
418.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:418.85-419.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.031 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.031 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.031”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · silverGrade: 6.7Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.7
Grade Unit
g/t
Intercept
0.95 m
From
418.85 m
To
419.8 m
Intercept Depth
418.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:418.85-419.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 6.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.4 g/t·m is below.

Negative factors

  • 6.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.7”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · copperGrade: 7Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.95 m
From
418.85 m
To
419.8 m
Intercept Depth
418.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:418.85-419.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · leadGrade: 7Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7
Grade Unit
g/t
Intercept
0.95 m
From
418.85 m
To
419.8 m
Intercept Depth
418.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:418.85-419.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 7 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“7”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · zincGrade: 20Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20
Grade Unit
g/t
Intercept
0.95 m
From
418.85 m
To
419.8 m
Intercept Depth
418.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:418.85-419.8

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.13
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 20 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“20”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · goldGrade: 0.013Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.013
Grade Unit
g/t
Intercept
2.6 m
From
455 m
To
457.6 m
Intercept Depth
455 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:455-457.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 0.013 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.013 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.013”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · silverGrade: 14.6Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14.6
Grade Unit
g/t
Intercept
2.6 m
From
455 m
To
457.6 m
Intercept Depth
455 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:455-457.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table. 14.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 38.0 g/t·m is below.

Negative factors

  • 14.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.6”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · copperGrade: 68Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
copper
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
68
Grade Unit
g/t
Intercept
2.6 m
From
455 m
To
457.6 m
Intercept Depth
455 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:455-457.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 68 g/t copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the copper rubric unit %; not scored.

Evidence · table

“68”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · leadGrade: 14Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
lead
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
2.6 m
From
455 m
To
457.6 m
Intercept Depth
455 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:455-457.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t lead, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the lead rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

MTH-RE25-59Copalquin · zincGrade: 14Grade Unit: g/tIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
MTH-RE25-59
Project
Copalquin
Commodity
zinc
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
2.6 m
From
455 m
To
457.6 m
Intercept Depth
455 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
MTH-RE25-59:455-457.6

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.22
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: Expanded from assay table: 14 g/t zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit g/t does not match the zinc rubric unit %; not scored.

Evidence · table

“14”

Context: MTH-RE25-59

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Resource Estimates (2)

inferredCopalquin · goldTonnes: 1725000Grade: 4.55Grade Unit: g/tContained Metal: 252Contained Unit: kozHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
Durango State, Mexico
Ticker
MSG

Resource scope

Estimate type
resource
Effective date
2021-11-17T00:00:00.000Z
Reporting standards
jorc, ni_43_101
QP Signed
Yes
Qualified person names
Rodney Webster, Andrew Proudman, John Skeet
Resource group id
resource:b86073f431b6999e3069
Deposit or zone
Total
Mining method
underground

Resource Data

Category
inferred
Tonnes
1725000
Grade
4.55
Grade Unit
g/t
Contained Metal
252
Contained Unit
koz
Cutoff Grade
2
Cutoff Unit
g/t AuEq

Prior Estimate

Resource Date
2021-11-17

Metal Equivalent

Metal Eq. Grade
6.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Lab

Laboratory
ALS Global

Review

Needs Review
Yes
Review Reason
historical_restatement
Historical
Yes
Historical Source Date
2021-11-17T00:00:00.000Z

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: This is a re-published historical total Inferred gold resource for Copalquin, compliant with JORC and NI 43-101 standards, but with lower confidence due to its category.

Positive factors

  • JORC and NI 43-101 compliant with QP/CP sign-off
  • Metal equivalent assumptions are disclosed

Negative factors

  • Resource is in the Inferred category, indicating lower geological confidence
  • This is a re-print of a historical estimate from 2021, not a new update

Evidence · table

“4.55”

Context: 1,725

Tags used in scoring

Inferred Resourcenegative

Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.

Why it applies: category is "inferred"

Cut-off Disclosedpositive

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Why it applies: cutoff_grade is stated

QP/CP Signedpositive

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: qp_signed is true

JORC Compliantpositive

Resource estimate prepared in compliance with JORC Code (Australia) — high reporting standard.

Why it applies: reporting_standards includes jorc

NI 43-101 Compliantpositive

Resource estimate prepared in compliance with NI 43-101 (Canada) — high reporting standard.

Why it applies: reporting_standards includes ni_43_101

Stale Estimatenegative

Effective date is >2 years old — data currency concern, may not reflect current geological understanding.

Why it applies: effective date is 4.2 years before this release

inferredCopalquin · silverTonnes: 1725000Grade: 151.7Grade Unit: g/tContained Metal: 8414Contained Unit: kozHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
Durango State, Mexico
Ticker
MSG

Resource scope

Estimate type
resource
Effective date
2021-11-17T00:00:00.000Z
Reporting standards
jorc, ni_43_101
QP Signed
Yes
Qualified person names
Rodney Webster, Andrew Proudman, John Skeet
Resource group id
resource:b86073f431b6999e3069
Deposit or zone
Total
Mining method
underground

Resource Data

Category
inferred
Tonnes
1725000
Grade
151.7
Grade Unit
g/t
Contained Metal
8414
Contained Unit
koz
Cutoff Grade
2
Cutoff Unit
g/t AuEq

Prior Estimate

Resource Date
2021-11-17

Metal Equivalent

Metal Eq. Grade
6.72
Metal Eq. Unit
g/t AuEq
Assumptions Disclosed
Yes

Lab

Laboratory
ALS Global

Review

Needs Review
Yes
Review Reason
historical_restatement
Historical
Yes
Historical Source Date
2021-11-17T00:00:00.000Z

Dates

Event date
2026-01-20T00:00:00.000Z

Reasoning: This is a re-published historical total Inferred silver resource for Copalquin, compliant with JORC and NI 43-101 standards, but with lower confidence due to its category.

Positive factors

  • JORC and NI 43-101 compliant with QP/CP sign-off
  • Metal equivalent assumptions are disclosed

Negative factors

  • Resource is in the Inferred category, indicating lower geological confidence
  • This is a re-print of a historical estimate from 2021, not a new update

Evidence · table

“151.7”

Context: 1,725

Tags used in scoring

Inferred Resourcenegative

Speculative category — limited drilling, geological continuity assumed but not confirmed. Cannot support economic studies alone.

Why it applies: category is "inferred"

Cut-off Disclosedpositive

Cut-off grade used for resource reporting is clearly stated, enabling like-for-like comparison.

Why it applies: cutoff_grade is stated

QP/CP Signedpositive

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: qp_signed is true

JORC Compliantpositive

Resource estimate prepared in compliance with JORC Code (Australia) — high reporting standard.

Why it applies: reporting_standards includes jorc

NI 43-101 Compliantpositive

Resource estimate prepared in compliance with NI 43-101 (Canada) — high reporting standard.

Why it applies: reporting_standards includes ni_43_101

Stale Estimatenegative

Effective date is >2 years old — data currency concern, may not reflect current geological understanding.

Why it applies: effective date is 4.2 years before this release

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.