Mithril Intercepts High-Grade Silver At Target 5 Returning 1,714 G/T AGEQ (5.8 G/T AU, 1,308 G/T AG) Over 1.0 M At The Copalquin District, Mexico

Original announcement by tmx on

Company
Mithril Silver and Gold Limited
Ticker
MSG
Exchange
TSX
Region
Durango State, Mexico
Primary commodity
Silver
Secondary commodities
Gold
Document categories
Drill results, Resource update
Extracted
2026-09-18 11:14:21 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Mithril Silver and Gold Limited announced high-grade silver and gold drill intercepts from its maiden drilling program at Target 5 within the Copalquin District, Mexico. Results include 1,714 g/t AgEq over 1.0 meter. The company also provided an update on its historical JORC-compliant mineral resource estimate for the El Refugio-La Soledad area, highlighting the district's overall gold-silver potential. Exploration is ongoing across multiple targets with further drilling planned.

Reasoning: The announcement reports high-grade gold and silver drill intercepts from a new exploration target, indicating significant potential for the Copalquin district. While the resource estimate is historical, the new drill results are positive for early-stage exploration.

Positive factors

  • High-grade silver and gold intercepts from maiden drilling at a new target (Target 5).
  • District-scale potential of the Copalquin project with multiple targets.
  • QA/QC procedures are disclosed, including use of ALS Global and QP sign-off.
  • Resource estimate supports high-grade gold and silver potential.

Negative factors

  • True widths are not always known for drill intercepts, potentially overstating lengths.
  • Resource estimate is historical (2021) and re-printed, not a new update.

Facts used in scoring: 288

Extracted facts

Stored fact records: 288. Some facts used in scoring do not have a stored record.

Drill Results (288)

AP25-001Copalquin · silverGrade: 7.4Grade Unit: g/tIntercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.4
Grade Unit
g/t
Intercept
2.75 m
From
13.75 m
To
16.5 m
Hole Depth
351 m
Intercept Depth
13.75 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:13.75-16.5
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept, but part of initial exploration drilling at a new target.

Evidence · table

“7.4”

Context: 2.75

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 39.3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39.3
Grade Unit
g/t
Intercept
0.5 m
From
32 m
To
32.5 m
Hole Depth
351 m
Intercept Depth
32 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:32-32.5
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
124
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“39.3”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 4.6Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.6
Grade Unit
g/t
Intercept
1.5 m
From
33.5 m
To
35 m
Hole Depth
351 m
Intercept Depth
33.5 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:33.5-35
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“4.6”

Context: 1.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 38.6Grade Unit: g/tIntercept: 0.57 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
38.6
Grade Unit
g/t
Intercept
0.57 m
From
38.1 m
To
38.67 m
Hole Depth
351 m
Intercept Depth
38.1 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:38.1-38.67
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
52.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“38.6”

Context: 0.57

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 7.8Grade Unit: g/tIntercept: 0.63 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.8
Grade Unit
g/t
Intercept
0.63 m
From
38.67 m
To
39.3 m
Hole Depth
351 m
Intercept Depth
38.67 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:38.67-39.3
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“7.8”

Context: 0.63

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 5.8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
1 m
From
48 m
To
49 m
Hole Depth
351 m
Intercept Depth
48 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:48-49
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5.8”

Context: 1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 5.9Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.9
Grade Unit
g/t
Intercept
2 m
From
86 m
To
88 m
Hole Depth
351 m
Intercept Depth
86 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:86-88
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5.9”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 26.5Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26.5
Grade Unit
g/t
Intercept
0.55 m
From
164.55 m
To
165.1 m
Hole Depth
351 m
Intercept Depth
164.55 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:164.55-165.1
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
35.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“26.5”

Context: 0.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 5.9Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.9
Grade Unit
g/t
Intercept
0.65 m
From
165.1 m
To
165.75 m
Hole Depth
351 m
Intercept Depth
165.1 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:165.1-165.75
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5.9”

Context: 0.65

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 5.8Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
1.3 m
From
207.75 m
To
209.05 m
Hole Depth
351 m
Intercept Depth
207.75 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:207.75-209.05
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5.8”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 11.6Grade Unit: g/tIntercept: 1.12 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.6
Grade Unit
g/t
Intercept
1.12 m
From
231.15 m
To
232.27 m
Hole Depth
351 m
Intercept Depth
231.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:231.15-232.27
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
15.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“11.6”

Context: 1.12

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 4.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
0.5 m
From
233.93 m
To
234.43 m
Hole Depth
351 m
Intercept Depth
233.93 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:233.93-234.43
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“4.2”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 167Grade Unit: g/tIntercept: 0.52 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
167
Grade Unit
g/t
Intercept
0.52 m
From
279.83 m
To
280.35 m
Hole Depth
351 m
Intercept Depth
279.83 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:279.83-280.35
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
257
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“167”

Context: 0.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · silverGrade: 9.9Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.9
Grade Unit
g/t
Intercept
0.9 m
From
328.4 m
To
329.3 m
Hole Depth
351 m
Intercept Depth
328.4 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-001:328.4-329.3
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
40 °
Dip
-48 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“9.9”

Context: 0.9

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 187Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
187
Grade Unit
g/t
Intercept
0.5 m
From
31.45 m
To
31.95 m
Hole Depth
252 m
Intercept Depth
31.45 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:31.45-31.95
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
728.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: High-grade silver intercept over a narrow width in early exploration.

Positive factors

  • High-grade silver intercept.

Evidence · table

“187”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 66.8Grade Unit: g/tIntercept: 0.52 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
66.8
Grade Unit
g/t
Intercept
0.52 m
From
31.95 m
To
32.47 m
Hole Depth
252 m
Intercept Depth
31.95 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:31.95-32.47
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
90.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“66.8”

Context: 0.52

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 48.8Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
48.8
Grade Unit
g/t
Intercept
0.5 m
From
33 m
To
33.5 m
Hole Depth
252 m
Intercept Depth
33 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:33-33.5
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
146.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“48.8”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 11.2Grade Unit: g/tIntercept: 0.87 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.2
Grade Unit
g/t
Intercept
0.87 m
From
34.43 m
To
35.3 m
Hole Depth
252 m
Intercept Depth
34.43 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:34.43-35.3
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
17.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“11.2”

Context: 0.87

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 13.3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13.3
Grade Unit
g/t
Intercept
0.5 m
From
46.15 m
To
46.65 m
Hole Depth
252 m
Intercept Depth
46.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:46.15-46.65
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
25.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“13.3”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 0.68 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
0.68 m
From
46.65 m
To
47.33 m
Hole Depth
252 m
Intercept Depth
46.65 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:46.65-47.33
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5.1”

Context: 0.68

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 8Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
1.05 m
From
50.2 m
To
51.25 m
Hole Depth
252 m
Intercept Depth
50.2 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:50.2-51.25
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“8”

Context: 1.05

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 7.4Grade Unit: g/tIntercept: 1.61 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.4
Grade Unit
g/t
Intercept
1.61 m
From
69.45 m
To
71.06 m
Hole Depth
252 m
Intercept Depth
69.45 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:69.45-71.06
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“7.4”

Context: 1.61

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 7.4Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.4
Grade Unit
g/t
Intercept
0.6 m
From
71.6 m
To
72.2 m
Hole Depth
252 m
Intercept Depth
71.6 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:71.6-72.2
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“7.4”

Context: 0.6

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 14Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14
Grade Unit
g/t
Intercept
0.5 m
From
78.3 m
To
78.8 m
Hole Depth
252 m
Intercept Depth
78.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:78.3-78.8
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
23.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“14”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 16.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16.9
Grade Unit
g/t
Intercept
0.5 m
From
103.55 m
To
104.05 m
Hole Depth
252 m
Intercept Depth
103.55 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:103.55-104.05
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
26.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“16.9”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 11.5Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.5
Grade Unit
g/t
Intercept
0.65 m
From
113.5 m
To
114.15 m
Hole Depth
252 m
Intercept Depth
113.5 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:113.5-114.15
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
17.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“11.5”

Context: 0.65

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 8.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.1
Grade Unit
g/t
Intercept
1.1 m
From
205.4 m
To
206.5 m
Hole Depth
252 m
Intercept Depth
205.4 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:205.4-206.5
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“8.1”

Context: 1.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 6.7Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.7
Grade Unit
g/t
Intercept
0.55 m
From
206.5 m
To
207.05 m
Hole Depth
252 m
Intercept Depth
206.5 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:206.5-207.05
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“6.7”

Context: 0.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 7.6Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.6
Grade Unit
g/t
Intercept
0.8 m
From
207.05 m
To
207.85 m
Hole Depth
252 m
Intercept Depth
207.05 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:207.05-207.85
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“7.6”

Context: 0.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 9.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.5
Grade Unit
g/t
Intercept
0.5 m
From
213.25 m
To
213.75 m
Hole Depth
252 m
Intercept Depth
213.25 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-002:213.25-213.75
Mining Method
mixed

Location

Easting
287909
Northing
2822588
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.01 m
Azimuth
63 °
Dip
-53 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“9.5”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 62.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
62.4
Grade Unit
g/t
Intercept
0.5 m
From
34.5 m
To
35 m
Hole Depth
285 m
Intercept Depth
34.5 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:34.5-35
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
89.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“62.4”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 6.4Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.4
Grade Unit
g/t
Intercept
0.55 m
From
40 m
To
40.55 m
Hole Depth
285 m
Intercept Depth
40 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:40-40.55
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“6.4”

Context: 0.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 4.2Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
0.8 m
From
72 m
To
72.8 m
Hole Depth
285 m
Intercept Depth
72 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:72-72.8
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“4.2”

Context: 0.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 33.2Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
33.2
Grade Unit
g/t
Intercept
0.8 m
From
78.35 m
To
79.15 m
Hole Depth
285 m
Intercept Depth
78.35 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:78.35-79.15
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
37.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“33.2”

Context: 0.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 13.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13.4
Grade Unit
g/t
Intercept
0.5 m
From
89.15 m
To
89.65 m
Hole Depth
285 m
Intercept Depth
89.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:89.15-89.65
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“13.4”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 15.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.5
Grade Unit
g/t
Intercept
0.5 m
From
90.15 m
To
90.65 m
Hole Depth
285 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:90.15-90.65
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“15.5”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 11.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.6
Grade Unit
g/t
Intercept
0.5 m
From
93.1 m
To
93.6 m
Hole Depth
285 m
Intercept Depth
93.1 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:93.1-93.6
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“11.6”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 60.7Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
60.7
Grade Unit
g/t
Intercept
0.55 m
From
93.6 m
To
94.15 m
Hole Depth
285 m
Intercept Depth
93.6 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:93.6-94.15
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“60.7”

Context: 0.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 27.4Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
27.4
Grade Unit
g/t
Intercept
0.55 m
From
94.15 m
To
94.7 m
Hole Depth
285 m
Intercept Depth
94.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:94.15-94.7
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
36.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“27.4”

Context: 0.55

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 1240Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1240
Grade Unit
g/t
Intercept
0.5 m
From
94.7 m
To
95.2 m
Hole Depth
285 m
Intercept Depth
94.7 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:94.7-95.2
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1699.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Exceptional silver grade over a narrow interval in early exploration.

Positive factors

  • Bonanza Intercept
  • High-grade silver intercept.

Evidence · table

“1240”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 1375Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1375
Grade Unit
g/t
Intercept
0.5 m
From
95.2 m
To
95.7 m
Hole Depth
285 m
Intercept Depth
95.2 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:95.2-95.7
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1724.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Exceptional silver grade over a narrow interval in early exploration.

Positive factors

  • Bonanza Intercept
  • High-grade silver intercept.

Evidence · table

“1375”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 30.2Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
30.2
Grade Unit
g/t
Intercept
0.65 m
From
95.7 m
To
96.35 m
Hole Depth
285 m
Intercept Depth
95.7 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:95.7-96.35
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
35.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“30.2”

Context: 0.65

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 6.6Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.6
Grade Unit
g/t
Intercept
2 m
From
119 m
To
121 m
Hole Depth
285 m
Intercept Depth
119 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:119-121
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“6.6”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 18.2Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18.2
Grade Unit
g/t
Intercept
2 m
From
121 m
To
123 m
Hole Depth
285 m
Intercept Depth
121 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:121-123
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
23.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“18.2”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 40.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40.6
Grade Unit
g/t
Intercept
0.5 m
From
186.55 m
To
187.05 m
Hole Depth
285 m
Intercept Depth
186.55 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:186.55-187.05
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
52
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“40.6”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 0.5Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
1.3 m
From
214 m
To
215.3 m
Hole Depth
285 m
Intercept Depth
214 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:214-215.3
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
202.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Very low silver grade, likely below economic cut-off, in early exploration.

Evidence · table

“0.5”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 26.8Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
26.8
Grade Unit
g/t
Intercept
0.5 m
From
215.3 m
To
215.8 m
Hole Depth
285 m
Intercept Depth
215.3 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:215.3-215.8
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
27.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“26.8”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 0.5Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
1.45 m
From
224 m
To
225.45 m
Hole Depth
285 m
Intercept Depth
224 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:224-225.45
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Very low silver grade, likely below economic cut-off, in early exploration.

Evidence · table

“0.5”

Context: 1.45

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 33.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
33.1
Grade Unit
g/t
Intercept
1.1 m
From
225.45 m
To
226.55 m
Hole Depth
285 m
Intercept Depth
225.45 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:225.45-226.55
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
34.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval in early exploration.

Evidence · table

“33.1”

Context: 1.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 1.5Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.5
Grade Unit
g/t
Intercept
0.7 m
From
231.6 m
To
232.3 m
Hole Depth
285 m
Intercept Depth
231.6 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:231.6-232.3
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
168.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Very low silver grade, likely below economic cut-off, in early exploration.

Evidence · table

“1.5”

Context: 0.7

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 6.9Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.9
Grade Unit
g/t
Intercept
2 m
From
234 m
To
236 m
Hole Depth
285 m
Intercept Depth
234 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-003:234-236
Mining Method
mixed

Location

Easting
287910
Northing
2822591
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
758.82 m
Azimuth
63 °
Dip
-69 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“6.9”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 13.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
13.2
Grade Unit
g/t
Intercept
0.5 m
From
30 m
To
30.5 m
Hole Depth
291 m
Intercept Depth
30 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:30-30.5
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
19.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“13.2”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 20.9Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20.9
Grade Unit
g/t
Intercept
0.6 m
From
40.75 m
To
41.35 m
Hole Depth
291 m
Intercept Depth
40.75 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:40.75-41.35
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
27.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“20.9”

Context: 0.6

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 16.1Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16.1
Grade Unit
g/t
Intercept
0.8 m
From
42.85 m
To
43.65 m
Hole Depth
291 m
Intercept Depth
42.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:42.85-43.65
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
22.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“16.1”

Context: 0.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 6.2Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.2
Grade Unit
g/t
Intercept
1.4 m
From
76.6 m
To
78 m
Hole Depth
291 m
Intercept Depth
76.6 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:76.6-78
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“6.2”

Context: 1.4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 3.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.9
Grade Unit
g/t
Intercept
0.5 m
From
88.7 m
To
89.2 m
Hole Depth
291 m
Intercept Depth
88.7 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:88.7-89.2
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“3.9”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 135Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
135
Grade Unit
g/t
Intercept
0.95 m
From
89.2 m
To
90.15 m
Hole Depth
291 m
Intercept Depth
89.2 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:89.2-90.15
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
186.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“135”

Context: 0.95

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 61.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
61.4
Grade Unit
g/t
Intercept
0.5 m
From
90.15 m
To
90.65 m
Hole Depth
291 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:90.15-90.65
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“61.4”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 7.5Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.5
Grade Unit
g/t
Intercept
0.85 m
From
91.15 m
To
92 m
Hole Depth
291 m
Intercept Depth
91.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:91.15-92
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“7.5”

Context: 0.85

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 2.5Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.5
Grade Unit
g/t
Intercept
2 m
From
92 m
To
94 m
Hole Depth
291 m
Intercept Depth
92 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:92-94
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
12.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Very low silver grade, likely below economic cut-off, in early exploration.

Evidence · table

“2.5”

Context: 2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 9.2Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.2
Grade Unit
g/t
Intercept
1.3 m
From
97 m
To
98.3 m
Hole Depth
291 m
Intercept Depth
97 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:97-98.3
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“9.2”

Context: 1.3

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9
Grade Unit
g/t
Intercept
0.5 m
From
105.9 m
To
106.4 m
Hole Depth
291 m
Intercept Depth
105.9 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:105.9-106.4
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“9”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 87.8Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
87.8
Grade Unit
g/t
Intercept
0.5 m
From
114.15 m
To
114.65 m
Hole Depth
291 m
Intercept Depth
114.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:114.15-114.65
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
114.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“87.8”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 16.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
16.6
Grade Unit
g/t
Intercept
0.5 m
From
152.45 m
To
152.95 m
Hole Depth
291 m
Intercept Depth
152.45 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:152.45-152.95
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“16.6”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 5.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.9
Grade Unit
g/t
Intercept
0.5 m
From
173.85 m
To
174.35 m
Hole Depth
291 m
Intercept Depth
173.85 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:173.85-174.35
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5.9”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 98Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
98
Grade Unit
g/t
Intercept
0.5 m
From
174.35 m
To
174.85 m
Hole Depth
291 m
Intercept Depth
174.35 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:174.35-174.85
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
146
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Moderate silver grade over a narrow interval in early exploration.

Evidence · table

“98”

Context: 0.5

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 1.7Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.7
Grade Unit
g/t
Intercept
0.8 m
From
238.15 m
To
238.95 m
Hole Depth
291 m
Intercept Depth
238.15 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:238.15-238.95
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Very low silver grade, likely below economic cut-off, in early exploration.

Evidence · table

“1.7”

Context: 0.8

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 5Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5
Grade Unit
g/t
Intercept
0.6 m
From
238.95 m
To
239.55 m
Hole Depth
291 m
Intercept Depth
238.95 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
AP25-004:238.95-239.55
Mining Method
mixed

Location

Easting
287903.2
Northing
2822590
CRS
UTM/UPS WGS 84 zone 13 N
Elevation
760.85 m
Azimuth
30 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes
Max Dilution
2 m

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Low-grade silver intercept in early exploration.

Evidence · table

“5”

Context: 0.6

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 1.21Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.21
Grade Unit
g/t
Intercept
0.5 m
From
32 m
To
32.5 m
Intercept Depth
32 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:32-32.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
124
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1.21 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.21”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 1.285Grade Unit: g/tIntercept: 0.52 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.285
Grade Unit
g/t
Intercept
0.52 m
From
279.83 m
To
280.35 m
Intercept Depth
279.83 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:279.83-280.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
256.95
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1.285 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.285”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 1.26Grade Unit: g/tIntercept: 3.85 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.26
Grade Unit
g/t
Intercept
3.85 m
From
31.45 m
To
35.3 m
Intercept Depth
31.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:31.45-35.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
130.85
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1.26 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 4.9 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.26”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · silverGrade: 42.65Grade Unit: g/tIntercept: 3.85 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
42.65
Grade Unit
g/t
Intercept
3.85 m
From
31.45 m
To
35.3 m
Intercept Depth
31.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:31.45-35.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
130.85
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 42.65 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 164.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“42.65”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 7.74Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.74
Grade Unit
g/t
Intercept
0.5 m
From
31.45 m
To
31.95 m
Intercept Depth
31.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:31.45-31.95
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
728.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 7.74 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.9 g/t·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 7.74 g/t gold is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.74”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.393Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.393
Grade Unit
g/t
Intercept
0.5 m
From
34.5 m
To
35 m
Intercept Depth
34.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:34.5-35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
89.91
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.393 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.393”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 2.28Grade Unit: g/tIntercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.28
Grade Unit
g/t
Intercept
2.75 m
From
93.6 m
To
96.35 m
Intercept Depth
93.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:93.6-96.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
659.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 2.28 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 6.3 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.28 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.28”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 500Grade Unit: g/tIntercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
500
Grade Unit
g/t
Intercept
2.75 m
From
93.6 m
To
96.35 m
Intercept Depth
93.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:93.6-96.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
659.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 500 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 1375.0 g/t·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 500 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“500”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 5.8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.8
Grade Unit
g/t
Intercept
1 m
From
94.7 m
To
95.7 m
Intercept Depth
94.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:94.7-95.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1713.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.8 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.8 g/t·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 5.8 g/t gold is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.8”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · silverGrade: 1307.5Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1307.5
Grade Unit
g/t
Intercept
1 m
From
94.7 m
To
95.7 m
Intercept Depth
94.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:94.7-95.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1713.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1307.5 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 1307.5 g/t·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1307.5 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1307.5”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 2.89Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.89
Grade Unit
g/t
Intercept
1.3 m
From
214 m
To
215.3 m
Intercept Depth
214 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:214-215.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
202.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 2.89 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.8 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.89 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.89”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 2.38Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.38
Grade Unit
g/t
Intercept
0.7 m
From
231.6 m
To
232.3 m
Intercept Depth
231.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:231.6-232.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
168.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 2.38 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.7 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.38 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.38”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.57Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.57
Grade Unit
g/t
Intercept
1.45 m
From
89.2 m
To
90.65 m
Intercept Depth
89.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:89.2-90.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
149.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.57”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 109.6Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
109.6
Grade Unit
g/t
Intercept
1.45 m
From
89.2 m
To
90.65 m
Intercept Depth
89.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:89.2-90.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
149.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 109.6 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 158.9 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“109.6”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
4.05 m
From
35.65 m
To
39.7 m
Intercept Depth
35.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:35.65-39.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
74.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 0.19 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.19”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 61.5Grade Unit: g/tIntercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
61.5
Grade Unit
g/t
Intercept
4.05 m
From
35.65 m
To
39.7 m
Intercept Depth
35.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:35.65-39.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
74.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 61.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 249.1 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“61.5”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.41Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
1.6 m
From
36.75 m
To
38.35 m
Intercept Depth
36.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:36.75-38.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
158.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.41 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.41”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 130Grade Unit: g/tIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
130
Grade Unit
g/t
Intercept
1.6 m
From
36.75 m
To
38.35 m
Intercept Depth
36.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:36.75-38.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
158.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 130 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 208.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“130”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 1.71Grade Unit: g/tIntercept: 3.35 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.71
Grade Unit
g/t
Intercept
3.35 m
From
90.15 m
To
93.5 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:90.15-93.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
365.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1.71 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.7 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.71”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 246Grade Unit: g/tIntercept: 3.35 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
246
Grade Unit
g/t
Intercept
3.35 m
From
90.15 m
To
93.5 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:90.15-93.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
365.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 246 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 824.1 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 246 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“246”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

(IncludingCopalquin · goldGrade: 5.35Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
(Including
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.35
Grade Unit
g/t
Intercept
1.05 m
From
92.45 m
To
93.5 m
Intercept Depth
92.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
(Including:92.45-93.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1145.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.35 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.6 g/t·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 5.35 g/t gold is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.35”

Context: (Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

(IncludingCopalquin · silverGrade: 771Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
(Including
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
771
Grade Unit
g/t
Intercept
1.05 m
From
92.45 m
To
93.5 m
Intercept Depth
92.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
(Including:92.45-93.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1145.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 771 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 809.6 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 771 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“771”

Context: (Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 4.548Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.548
Grade Unit
g/t
Intercept
1.25 m
From
119.2 m
To
120.45 m
Intercept Depth
119.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:119.2-120.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
727.48
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 4.548 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.7 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 4.548 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.548”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 409.12Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
409.12
Grade Unit
g/t
Intercept
1.25 m
From
119.2 m
To
120.45 m
Intercept Depth
119.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:119.2-120.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
727.48
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 409.12 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 511.4 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 409.12 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“409.12”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 2.41Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.41
Grade Unit
g/t
Intercept
0.9 m
From
138.1 m
To
139 m
Intercept Depth
138.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:138.1-139
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
615.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 2.41 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.2 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.41 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.41”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 447Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
447
Grade Unit
g/t
Intercept
0.9 m
From
138.1 m
To
139 m
Intercept Depth
138.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:138.1-139
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
615.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 447 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 402.3 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 447 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“447”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 1.51Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.51
Grade Unit
g/t
Intercept
0.8 m
From
149.75 m
To
150.55 m
Intercept Depth
149.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:149.75-150.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
426.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1.51 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.2 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.51”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 321Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
321
Grade Unit
g/t
Intercept
0.8 m
From
149.75 m
To
150.55 m
Intercept Depth
149.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:149.75-150.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
426.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 321 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 256.8 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 321 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“321”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.187Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.187
Grade Unit
g/t
Intercept
0.5 m
From
301.4 m
To
301.9 m
Intercept Depth
301.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:301.4-301.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
86.09
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.187 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.187 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.187”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 73Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
73
Grade Unit
g/t
Intercept
0.5 m
From
301.4 m
To
301.9 m
Intercept Depth
301.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:301.4-301.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
86.09
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 73 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 36.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“73”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.23Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.23
Grade Unit
g/t
Intercept
1.5 m
From
51 m
To
52.5 m
Intercept Depth
51 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:51-52.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
31.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.23 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.23”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 15.2Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.2
Grade Unit
g/t
Intercept
1.5 m
From
51 m
To
52.5 m
Intercept Depth
51 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:51-52.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
31.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 15.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 22.8 g/t·m is below.

Negative factors

  • 15.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.2”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.27Grade Unit: g/tIntercept: 2.05 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.27
Grade Unit
g/t
Intercept
2.05 m
From
62.75 m
To
64.8 m
Intercept Depth
62.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:62.75-64.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
107
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below.

Negative factors

  • 0.27 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 88.1Grade Unit: g/tIntercept: 2.05 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
88.1
Grade Unit
g/t
Intercept
2.05 m
From
62.75 m
To
64.8 m
Intercept Depth
62.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:62.75-64.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
107
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 88.1 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 180.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“88.1”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.9
Grade Unit
g/t
Intercept
0.5 m
From
64.3 m
To
64.8 m
Intercept Depth
64.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:64.3-64.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
374
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.9”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 311Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
311
Grade Unit
g/t
Intercept
0.5 m
From
64.3 m
To
64.8 m
Intercept Depth
64.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:64.3-64.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
374
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 311 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 155.5 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 311 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“311”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-008Copalquin · goldGrade: 0.344Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-008
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.344
Grade Unit
g/t
Intercept
0.7 m
From
78.2 m
To
78.9 m
Intercept Depth
78.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-008:78.2-78.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
35.98
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.344 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.344”

Context: AP25-008

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-008Copalquin · silverGrade: 11.9Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-008
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.9
Grade Unit
g/t
Intercept
0.7 m
From
78.2 m
To
78.9 m
Intercept Depth
78.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-008:78.2-78.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
35.98
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 11.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.3 g/t·m is below.

Negative factors

  • 11.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“11.9”

Context: AP25-008

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.023Grade Unit: g/tIntercept: 2.75 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.023
Grade Unit
g/t
Intercept
2.75 m
From
13.75 m
To
16.5 m
Intercept Depth
13.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:13.75-16.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.023 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.023 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.023”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.068Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.068
Grade Unit
g/t
Intercept
1.5 m
From
33.5 m
To
35 m
Intercept Depth
33.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:33.5-35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.068 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.068 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.068”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.203Grade Unit: g/tIntercept: 0.57 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.203
Grade Unit
g/t
Intercept
0.57 m
From
38.1 m
To
38.67 m
Intercept Depth
38.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:38.1-38.67
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
52.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.203 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.203 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.203”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.058Grade Unit: g/tIntercept: 0.63 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.058
Grade Unit
g/t
Intercept
0.63 m
From
38.67 m
To
39.3 m
Intercept Depth
38.67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:38.67-39.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.058 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.058 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.058”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.025Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.025
Grade Unit
g/t
Intercept
1 m
From
48 m
To
49 m
Intercept Depth
48 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:48-49
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.025 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.025 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.025”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.028Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.028
Grade Unit
g/t
Intercept
2 m
From
86 m
To
88 m
Intercept Depth
86 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:86-88
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.028 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.028 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.028”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.134Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.134
Grade Unit
g/t
Intercept
0.55 m
From
164.55 m
To
165.1 m
Intercept Depth
164.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:164.55-165.1
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
35.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.134 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.134 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.134”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.039Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.039
Grade Unit
g/t
Intercept
0.65 m
From
165.1 m
To
165.75 m
Intercept Depth
165.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:165.1-165.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.039 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.039 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.039”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.059Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.059
Grade Unit
g/t
Intercept
1.3 m
From
207.75 m
To
209.05 m
Intercept Depth
207.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:207.75-209.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.059 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.059 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.059”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.053Grade Unit: g/tIntercept: 1.12 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.053
Grade Unit
g/t
Intercept
1.12 m
From
231.15 m
To
232.27 m
Intercept Depth
231.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:231.15-232.27
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
15.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.053 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.053 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.053”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.141Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.141
Grade Unit
g/t
Intercept
0.5 m
From
233.93 m
To
234.43 m
Intercept Depth
233.93 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:233.93-234.43
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.141 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.141 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.141”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-001Copalquin · goldGrade: 0.055Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-001
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.055
Grade Unit
g/t
Intercept
0.9 m
From
328.4 m
To
329.3 m
Intercept Depth
328.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-001:328.4-329.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.055 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.055 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.055”

Context: AP25-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.338Grade Unit: g/tIntercept: 0.52 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.338
Grade Unit
g/t
Intercept
0.52 m
From
31.95 m
To
32.47 m
Intercept Depth
31.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:31.95-32.47
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
90.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.338 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.338”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 1.39Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1.39
Grade Unit
g/t
Intercept
0.5 m
From
33 m
To
33.5 m
Intercept Depth
33 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:33-33.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
146.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1.39 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.39”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.096Grade Unit: g/tIntercept: 0.87 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.096
Grade Unit
g/t
Intercept
0.87 m
From
34.43 m
To
35.3 m
Intercept Depth
34.43 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:34.43-35.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
17.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.096 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.096 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.096”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.178Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.178
Grade Unit
g/t
Intercept
0.5 m
From
46.15 m
To
46.65 m
Intercept Depth
46.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:46.15-46.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
25.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.178 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.178 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.178”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.057Grade Unit: g/tIntercept: 0.68 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.057
Grade Unit
g/t
Intercept
0.68 m
From
46.65 m
To
47.33 m
Intercept Depth
46.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:46.65-47.33
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.057 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.057 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.057”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.012Grade Unit: g/tIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.012
Grade Unit
g/t
Intercept
1.05 m
From
50.2 m
To
51.25 m
Intercept Depth
50.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:50.2-51.25
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.012 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.012 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.012”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.037Grade Unit: g/tIntercept: 1.61 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.037
Grade Unit
g/t
Intercept
1.61 m
From
69.45 m
To
71.06 m
Intercept Depth
69.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:69.45-71.06
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.037 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.037 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.037”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.061Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.061
Grade Unit
g/t
Intercept
0.6 m
From
71.6 m
To
72.2 m
Intercept Depth
71.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:71.6-72.2
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.061 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.061 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.061”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.138Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.138
Grade Unit
g/t
Intercept
0.5 m
From
78.3 m
To
78.8 m
Intercept Depth
78.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:78.3-78.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
23.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.138 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.138 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.138”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.136Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.136
Grade Unit
g/t
Intercept
0.5 m
From
103.55 m
To
104.05 m
Intercept Depth
103.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:103.55-104.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
26.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.136 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.136 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.136”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.083Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.083
Grade Unit
g/t
Intercept
0.65 m
From
113.5 m
To
114.15 m
Intercept Depth
113.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:113.5-114.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
17.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.083 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.083 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.083”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.088Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.088
Grade Unit
g/t
Intercept
1.1 m
From
205.4 m
To
206.5 m
Intercept Depth
205.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:205.4-206.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.088 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.088 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.088”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.072Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.072
Grade Unit
g/t
Intercept
0.55 m
From
206.5 m
To
207.05 m
Intercept Depth
206.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:206.5-207.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.072 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.072 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.072”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
0.8 m
From
207.05 m
To
207.85 m
Intercept Depth
207.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:207.05-207.85
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.19 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.19”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-002Copalquin · goldGrade: 0.063Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-002
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.063
Grade Unit
g/t
Intercept
0.5 m
From
213.25 m
To
213.75 m
Intercept Depth
213.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-002:213.25-213.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.063 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.063 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.063”

Context: AP25-002

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.038Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.038
Grade Unit
g/t
Intercept
0.55 m
From
40 m
To
40.55 m
Intercept Depth
40 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:40-40.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.038 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.038 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.038”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.048Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.048
Grade Unit
g/t
Intercept
0.8 m
From
72 m
To
72.8 m
Intercept Depth
72 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:72-72.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.048 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.048 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.048”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.059Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.059
Grade Unit
g/t
Intercept
0.8 m
From
78.35 m
To
79.15 m
Intercept Depth
78.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:78.35-79.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
37.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.059 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.059 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.059”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.099Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.099
Grade Unit
g/t
Intercept
0.5 m
From
89.15 m
To
89.65 m
Intercept Depth
89.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:89.15-89.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.099 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.099 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.099”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.047Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.047
Grade Unit
g/t
Intercept
0.5 m
From
90.15 m
To
90.65 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:90.15-90.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.047 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.047 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.047”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.043Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.043
Grade Unit
g/t
Intercept
0.5 m
From
93.1 m
To
93.6 m
Intercept Depth
93.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:93.1-93.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.043 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.043 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.043”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.695Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.695
Grade Unit
g/t
Intercept
0.55 m
From
93.6 m
To
94.15 m
Intercept Depth
93.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:93.6-94.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
109.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.695 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.695”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.128Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.128
Grade Unit
g/t
Intercept
0.55 m
From
94.15 m
To
94.7 m
Intercept Depth
94.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:94.15-94.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
36.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.128 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.128 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.128”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 6.56Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.56
Grade Unit
g/t
Intercept
0.5 m
From
94.7 m
To
95.2 m
Intercept Depth
94.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:94.7-95.2
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1699.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6.56 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.3 g/t·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 6.56 g/t gold is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.56”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 4.99Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.99
Grade Unit
g/t
Intercept
0.5 m
From
95.2 m
To
95.7 m
Intercept Depth
95.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:95.2-95.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1724.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 4.99 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.5 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 4.99 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.99”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.082Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.082
Grade Unit
g/t
Intercept
0.65 m
From
95.7 m
To
96.35 m
Intercept Depth
95.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:95.7-96.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
35.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.082 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.082 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.082”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.017Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.017
Grade Unit
g/t
Intercept
2 m
From
119 m
To
121 m
Intercept Depth
119 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:119-121
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.017 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.017 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.017”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.081Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.081
Grade Unit
g/t
Intercept
2 m
From
121 m
To
123 m
Intercept Depth
121 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:121-123
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
23.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.081 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.081 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.081”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.163Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.163
Grade Unit
g/t
Intercept
0.5 m
From
186.55 m
To
187.05 m
Intercept Depth
186.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:186.55-187.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
52
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.163 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.163 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.163”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.008Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.008
Grade Unit
g/t
Intercept
0.5 m
From
215.3 m
To
215.8 m
Intercept Depth
215.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:215.3-215.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
27.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.008 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.008 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.008”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.104Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.104
Grade Unit
g/t
Intercept
1.45 m
From
224 m
To
225.45 m
Intercept Depth
224 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:224-225.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.104 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.

Negative factors

  • 0.104 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.104”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.019Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.019
Grade Unit
g/t
Intercept
1.1 m
From
225.45 m
To
226.55 m
Intercept Depth
225.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:225.45-226.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
34.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.019 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.019 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.019”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-003Copalquin · goldGrade: 0.014Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-003
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.014
Grade Unit
g/t
Intercept
2 m
From
234 m
To
236 m
Intercept Depth
234 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-003:234-236
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.014 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.014 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.014”

Context: AP25-003

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.09
Grade Unit
g/t
Intercept
0.5 m
From
30 m
To
30.5 m
Intercept Depth
30 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:30-30.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
19.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.094Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.094
Grade Unit
g/t
Intercept
0.6 m
From
40.75 m
To
41.35 m
Intercept Depth
40.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:40.75-41.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
27.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.094 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.094 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.094”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.094Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.094
Grade Unit
g/t
Intercept
0.8 m
From
42.85 m
To
43.65 m
Intercept Depth
42.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:42.85-43.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
22.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.094 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.094 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.094”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.053Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.053
Grade Unit
g/t
Intercept
1.4 m
From
76.6 m
To
78 m
Intercept Depth
76.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:76.6-78
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.053 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.053 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.053”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.081Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.081
Grade Unit
g/t
Intercept
0.5 m
From
88.7 m
To
89.2 m
Intercept Depth
88.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:88.7-89.2
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.081 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.081 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.081”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.74Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.74
Grade Unit
g/t
Intercept
0.95 m
From
89.2 m
To
90.15 m
Intercept Depth
89.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:89.2-90.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
186.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.74 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.74”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.259Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.259
Grade Unit
g/t
Intercept
0.5 m
From
90.15 m
To
90.65 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:90.15-90.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
79.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.259 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.259 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.259”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.05Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.05
Grade Unit
g/t
Intercept
0.85 m
From
91.15 m
To
92 m
Intercept Depth
91.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:91.15-92
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.05 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.139Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.139
Grade Unit
g/t
Intercept
2 m
From
92 m
To
94 m
Intercept Depth
92 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:92-94
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
12.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.139 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.139 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.139”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.017Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.017
Grade Unit
g/t
Intercept
1.3 m
From
97 m
To
98.3 m
Intercept Depth
97 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:97-98.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.017 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.017 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.017”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.036Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.036
Grade Unit
g/t
Intercept
0.5 m
From
105.9 m
To
106.4 m
Intercept Depth
105.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:105.9-106.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.036 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.036 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.036”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.385Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.385
Grade Unit
g/t
Intercept
0.5 m
From
114.15 m
To
114.65 m
Intercept Depth
114.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:114.15-114.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
114.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.385 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.385”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.062Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.062
Grade Unit
g/t
Intercept
0.5 m
From
152.45 m
To
152.95 m
Intercept Depth
152.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:152.45-152.95
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.062 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.062 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.062”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.035Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.035
Grade Unit
g/t
Intercept
0.5 m
From
173.85 m
To
174.35 m
Intercept Depth
173.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:173.85-174.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.035 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.035 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.035”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.685Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.685
Grade Unit
g/t
Intercept
0.5 m
From
174.35 m
To
174.85 m
Intercept Depth
174.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:174.35-174.85
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
146
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.685 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.685”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.169Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.169
Grade Unit
g/t
Intercept
0.8 m
From
238.15 m
To
238.95 m
Intercept Depth
238.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:238.15-238.95
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.169 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.169 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.169”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.041Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.041
Grade Unit
g/t
Intercept
0.6 m
From
238.95 m
To
239.55 m
Intercept Depth
238.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:238.95-239.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.041 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.041 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.041”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.063Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.063
Grade Unit
g/t
Intercept
0.5 m
From
262 m
To
262.5 m
Intercept Depth
262 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:262-262.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.063 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.063 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.063”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 4.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
0.5 m
From
262 m
To
262.5 m
Intercept Depth
262 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:262-262.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 4.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.1 g/t·m is below.

Negative factors

  • 4.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.2”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.059Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.059
Grade Unit
g/t
Intercept
0.5 m
From
266.45 m
To
266.95 m
Intercept Depth
266.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:266.45-266.95
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.059 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.059 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.059”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 2.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
2.9
Grade Unit
g/t
Intercept
0.5 m
From
266.45 m
To
266.95 m
Intercept Depth
266.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:266.45-266.95
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.4 g/t·m is below.

Negative factors

  • 2.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.9”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · goldGrade: 0.027Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.027
Grade Unit
g/t
Intercept
0.55 m
From
269.05 m
To
269.6 m
Intercept Depth
269.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:269.05-269.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.027 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.027 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.027”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-004Copalquin · silverGrade: 6.5Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-004
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.5
Grade Unit
g/t
Intercept
0.55 m
From
269.05 m
To
269.6 m
Intercept Depth
269.05 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-004:269.05-269.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 6.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.5”

Context: AP25-004

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.005Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.005
Grade Unit
g/t
Intercept
2 m
From
20 m
To
22 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:20-22
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.005 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.005 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.005”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 9.6Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.6
Grade Unit
g/t
Intercept
2 m
From
20 m
To
22 m
Intercept Depth
20 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:20-22
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 9.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 19.2 g/t·m is below.

Negative factors

  • 9.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.6”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.043Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.043
Grade Unit
g/t
Intercept
1.1 m
From
35.65 m
To
36.75 m
Intercept Depth
35.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:35.65-36.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.043 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.043 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.043”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 15.5Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.5
Grade Unit
g/t
Intercept
1.1 m
From
35.65 m
To
36.75 m
Intercept Depth
35.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:35.65-36.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
18.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 15.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 17.1 g/t·m is below.

Negative factors

  • 15.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.5”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.342Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.342
Grade Unit
g/t
Intercept
0.5 m
From
36.75 m
To
37.25 m
Intercept Depth
36.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:36.75-37.25
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
122.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.342 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.342”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 99Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
99
Grade Unit
g/t
Intercept
0.5 m
From
36.75 m
To
37.25 m
Intercept Depth
36.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:36.75-37.25
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
122.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 99 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 49.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“99”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.775Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.775
Grade Unit
g/t
Intercept
0.55 m
From
37.25 m
To
37.8 m
Intercept Depth
37.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:37.25-37.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
290.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.775 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.775”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 236Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
236
Grade Unit
g/t
Intercept
0.55 m
From
37.25 m
To
37.8 m
Intercept Depth
37.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:37.25-37.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
290.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 236 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 129.8 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 236 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“236”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.119Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.119
Grade Unit
g/t
Intercept
0.55 m
From
37.8 m
To
38.35 m
Intercept Depth
37.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:37.8-38.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
60.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.119 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.119 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.119”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 52.6Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
52.6
Grade Unit
g/t
Intercept
0.55 m
From
37.8 m
To
38.35 m
Intercept Depth
37.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:37.8-38.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
60.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 52.6 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 28.9 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“52.6”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.036Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.036
Grade Unit
g/t
Intercept
1.35 m
From
38.35 m
To
39.7 m
Intercept Depth
38.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:38.35-39.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.036 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.036 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.036”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 18Grade Unit: g/tIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
18
Grade Unit
g/t
Intercept
1.35 m
From
38.35 m
To
39.7 m
Intercept Depth
38.35 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:38.35-39.7
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
20.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 18 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 24.3 g/t·m is below.

Negative factors

  • 18 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“18”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.108Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.108
Grade Unit
g/t
Intercept
0.9 m
From
48.65 m
To
49.55 m
Intercept Depth
48.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:48.65-49.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
28.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.108 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.108 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.108”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 20.9Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20.9
Grade Unit
g/t
Intercept
0.9 m
From
48.65 m
To
49.55 m
Intercept Depth
48.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:48.65-49.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
28.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 20.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 18.8 g/t·m is below.

Negative factors

  • 20.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“20.9”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.091Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.091
Grade Unit
g/t
Intercept
0.5 m
From
51.3 m
To
51.8 m
Intercept Depth
51.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:51.3-51.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
21.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.091 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.091 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.091”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 14.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
14.9
Grade Unit
g/t
Intercept
0.5 m
From
51.3 m
To
51.8 m
Intercept Depth
51.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:51.3-51.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
21.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 14.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.5 g/t·m is below.

Negative factors

  • 14.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14.9”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.091Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.091
Grade Unit
g/t
Intercept
0.5 m
From
88 m
To
88.5 m
Intercept Depth
88 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:88-88.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.091 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.091 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.091”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 6.8Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.8
Grade Unit
g/t
Intercept
0.5 m
From
88 m
To
88.5 m
Intercept Depth
88 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:88-88.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.4 g/t·m is below.

Negative factors

  • 6.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.8”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.041Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.041
Grade Unit
g/t
Intercept
0.65 m
From
89.5 m
To
90.15 m
Intercept Depth
89.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:89.5-90.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.041 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.041 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.041”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
0.65 m
From
89.5 m
To
90.15 m
Intercept Depth
89.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:89.5-90.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.3 g/t·m is below.

Negative factors

  • 5.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.1”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.159Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.159
Grade Unit
g/t
Intercept
0.5 m
From
90.15 m
To
90.65 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:90.15-90.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
36.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.159 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.159 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.159”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 25.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
25.1
Grade Unit
g/t
Intercept
0.5 m
From
90.15 m
To
90.65 m
Intercept Depth
90.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:90.15-90.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
36.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 25.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 12.6 g/t·m is below.

Negative factors

  • 25.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“25.1”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 7.04Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.04
Grade Unit
g/t
Intercept
0.55 m
From
92.45 m
To
93 m
Intercept Depth
92.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:92.45-93
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1582.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 7.04 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.9 g/t·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 7.04 g/t gold is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.04”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 1090Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
1090
Grade Unit
g/t
Intercept
0.55 m
From
92.45 m
To
93 m
Intercept Depth
92.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:92.45-93
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1582.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 1090 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 599.5 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1090 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1090”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 3.5Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.5
Grade Unit
g/t
Intercept
0.5 m
From
93 m
To
93.5 m
Intercept Depth
93 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:93-93.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
665
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.8 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 3.5 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.5”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 420Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
420
Grade Unit
g/t
Intercept
0.5 m
From
93 m
To
93.5 m
Intercept Depth
93 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:93-93.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
665
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 420 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 210.0 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 420 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“420”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.054Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.054
Grade Unit
g/t
Intercept
0.95 m
From
110.6 m
To
111.55 m
Intercept Depth
110.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:110.6-111.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.054 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.054 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.054”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 4.6Grade Unit: g/tIntercept: 0.95 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.6
Grade Unit
g/t
Intercept
0.95 m
From
110.6 m
To
111.55 m
Intercept Depth
110.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:110.6-111.55
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 4.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.4 g/t·m is below.

Negative factors

  • 4.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.6”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.067Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.067
Grade Unit
g/t
Intercept
0.5 m
From
114.55 m
To
115.05 m
Intercept Depth
114.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:114.55-115.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.067 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.067 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.067”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 5.6Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.6
Grade Unit
g/t
Intercept
0.5 m
From
114.55 m
To
115.05 m
Intercept Depth
114.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:114.55-115.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.8 g/t·m is below.

Negative factors

  • 5.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.6”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.321Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.321
Grade Unit
g/t
Intercept
0.5 m
From
116.5 m
To
117 m
Intercept Depth
116.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:116.5-117
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
95.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.321 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.321”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 72.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
72.9
Grade Unit
g/t
Intercept
0.5 m
From
116.5 m
To
117 m
Intercept Depth
116.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:116.5-117
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
95.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 72.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 36.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“72.9”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.041Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.041
Grade Unit
g/t
Intercept
0.75 m
From
119 m
To
119.75 m
Intercept Depth
119 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:119-119.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.041 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.041 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.041”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 4.8Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.8
Grade Unit
g/t
Intercept
0.75 m
From
119 m
To
119.75 m
Intercept Depth
119 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:119-119.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 4.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 4.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.8”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.043Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.043
Grade Unit
g/t
Intercept
0.7 m
From
119.75 m
To
120.45 m
Intercept Depth
119.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:119.75-120.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.043 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.043 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.043”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 4.3Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
4.3
Grade Unit
g/t
Intercept
0.7 m
From
119.75 m
To
120.45 m
Intercept Depth
119.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:119.75-120.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 4.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.0 g/t·m is below.

Negative factors

  • 4.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.3”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.138Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.138
Grade Unit
g/t
Intercept
0.6 m
From
120.45 m
To
121.05 m
Intercept Depth
120.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:120.45-121.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
29.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.138 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.138 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.138”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 20.1Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
20.1
Grade Unit
g/t
Intercept
0.6 m
From
120.45 m
To
121.05 m
Intercept Depth
120.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:120.45-121.05
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
29.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 20.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 12.1 g/t·m is below.

Negative factors

  • 20.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“20.1”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.026Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.026
Grade Unit
g/t
Intercept
1.1 m
From
213.5 m
To
214.6 m
Intercept Depth
213.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:213.5-214.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.026 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.026 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.026”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 7.1Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.1
Grade Unit
g/t
Intercept
1.1 m
From
213.5 m
To
214.6 m
Intercept Depth
213.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:213.5-214.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 7.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.8 g/t·m is below.

Negative factors

  • 7.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.1”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.317Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.317
Grade Unit
g/t
Intercept
0.5 m
From
232 m
To
232.5 m
Intercept Depth
232 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:232-232.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
83.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.317 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.317”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 61.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
61.2
Grade Unit
g/t
Intercept
0.5 m
From
232 m
To
232.5 m
Intercept Depth
232 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:232-232.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
83.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 61.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 30.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“61.2”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.008Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.008
Grade Unit
g/t
Intercept
1.55 m
From
246.45 m
To
248 m
Intercept Depth
246.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:246.45-248
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.008 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.008 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.008”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 7.6Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.6
Grade Unit
g/t
Intercept
1.55 m
From
246.45 m
To
248 m
Intercept Depth
246.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:246.45-248
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 7.6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.8 g/t·m is below.

Negative factors

  • 7.6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.6”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.006Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.006
Grade Unit
g/t
Intercept
1 m
From
248 m
To
249 m
Intercept Depth
248 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:248-249
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.006 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.006 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.006”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 8Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
1 m
From
248 m
To
249 m
Intercept Depth
248 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:248-249
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.0 g/t·m is below.

Negative factors

  • 8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.074Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.074
Grade Unit
g/t
Intercept
1.5 m
From
249 m
To
250.5 m
Intercept Depth
249 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:249-250.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
17.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.074 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.074 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.074”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 12.3Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12.3
Grade Unit
g/t
Intercept
1.5 m
From
249 m
To
250.5 m
Intercept Depth
249 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:249-250.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
17.5
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 12.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 18.5 g/t·m is below.

Negative factors

  • 12.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12.3”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.044Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.044
Grade Unit
g/t
Intercept
0.5 m
From
304.6 m
To
305.1 m
Intercept Depth
304.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:304.6-305.1
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.044 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.044 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.044”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 3.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.9
Grade Unit
g/t
Intercept
0.5 m
From
304.6 m
To
305.1 m
Intercept Depth
304.6 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:304.6-305.1
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 3.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.9 g/t·m is below.

Negative factors

  • 3.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.9”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.032Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.032
Grade Unit
g/t
Intercept
0.5 m
From
321 m
To
321.5 m
Intercept Depth
321 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:321-321.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
24.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.032 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.032 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.032”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 21.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
21.9
Grade Unit
g/t
Intercept
0.5 m
From
321 m
To
321.5 m
Intercept Depth
321 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:321-321.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
24.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 21.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 10.9 g/t·m is below.

Negative factors

  • 21.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“21.9”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.028Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.028
Grade Unit
g/t
Intercept
0.7 m
From
321.5 m
To
322.2 m
Intercept Depth
321.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:321.5-322.2
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.028 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.028 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.028”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 5.1Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.1
Grade Unit
g/t
Intercept
0.7 m
From
321.5 m
To
322.2 m
Intercept Depth
321.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:321.5-322.2
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.6 g/t·m is below.

Negative factors

  • 5.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.1”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · goldGrade: 0.16Grade Unit: g/tIntercept: 1.65 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
1.65 m
From
346.7 m
To
348.35 m
Intercept Depth
346.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:346.7-348.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.16 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-005Copalquin · silverGrade: 0.5Grade Unit: g/tIntercept: 1.65 mView all details
Link to this fact

Identity

Hole ID
AP25-005
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
1.65 m
From
346.7 m
To
348.35 m
Intercept Depth
346.7 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-005:346.7-348.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.8 g/t·m is below.

Negative factors

  • 0.5 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.5”

Context: AP25-005

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.033Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.033
Grade Unit
g/t
Intercept
0.75 m
From
47.25 m
To
48 m
Intercept Depth
47.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:47.25-48
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
32.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.033 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.033 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.033”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 30.4Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
30.4
Grade Unit
g/t
Intercept
0.75 m
From
47.25 m
To
48 m
Intercept Depth
47.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:47.25-48
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
32.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 30.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 22.8 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“30.4”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.019Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.019
Grade Unit
g/t
Intercept
1.45 m
From
66.3 m
To
67.75 m
Intercept Depth
66.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:66.3-67.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.019 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.019 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.019”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 6Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
1.45 m
From
66.3 m
To
67.75 m
Intercept Depth
66.3 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:66.3-67.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.7 g/t·m is below.

Negative factors

  • 6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 5.51Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.51
Grade Unit
g/t
Intercept
0.6 m
From
119.2 m
To
119.8 m
Intercept Depth
119.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:119.2-119.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
817.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.51 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.3 g/t·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 5.51 g/t gold is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.51”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 432Grade Unit: g/tIntercept: 0.6 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
432
Grade Unit
g/t
Intercept
0.6 m
From
119.2 m
To
119.8 m
Intercept Depth
119.2 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:119.2-119.8
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
817.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 432 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 259.2 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 432 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“432”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 3.66Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
3.66
Grade Unit
g/t
Intercept
0.65 m
From
119.8 m
To
120.45 m
Intercept Depth
119.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:119.8-120.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
644.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 3.66 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.4 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 3.66 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.66”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 388Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
388
Grade Unit
g/t
Intercept
0.65 m
From
119.8 m
To
120.45 m
Intercept Depth
119.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:119.8-120.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
644.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 388 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 252.2 g/t·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 388 g/t silver is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“388”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.095Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.095
Grade Unit
g/t
Intercept
1.55 m
From
120.45 m
To
122 m
Intercept Depth
120.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:120.45-122
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
19
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.095 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.095 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.095”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 12.3Grade Unit: g/tIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
12.3
Grade Unit
g/t
Intercept
1.55 m
From
120.45 m
To
122 m
Intercept Depth
120.45 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:120.45-122
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
19
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 12.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 19.1 g/t·m is below.

Negative factors

  • 12.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“12.3”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.047Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.047
Grade Unit
g/t
Intercept
0.5 m
From
148.25 m
To
148.75 m
Intercept Depth
148.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:148.25-148.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.047 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.047 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.047”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 6.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.1
Grade Unit
g/t
Intercept
0.5 m
From
148.25 m
To
148.75 m
Intercept Depth
148.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:148.25-148.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.0 g/t·m is below.

Negative factors

  • 6.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.1”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.065Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.065
Grade Unit
g/t
Intercept
0.5 m
From
148.75 m
To
149.25 m
Intercept Depth
148.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:148.75-149.25
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.065 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.065 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.065”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 11.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
11.4
Grade Unit
g/t
Intercept
0.5 m
From
148.75 m
To
149.25 m
Intercept Depth
148.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:148.75-149.25
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 11.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.7 g/t·m is below.

Negative factors

  • 11.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“11.4”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.131Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.131
Grade Unit
g/t
Intercept
0.5 m
From
149.25 m
To
149.75 m
Intercept Depth
149.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:149.25-149.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
31.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.131 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.131 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.131”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 22.7Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
22.7
Grade Unit
g/t
Intercept
0.5 m
From
149.25 m
To
149.75 m
Intercept Depth
149.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:149.25-149.75
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
31.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 22.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.3 g/t·m is below.

Negative factors

  • 22.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“22.7”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.045Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.045
Grade Unit
g/t
Intercept
0.85 m
From
150.55 m
To
151.4 m
Intercept Depth
150.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:150.55-151.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
12.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.045 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.045 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.045”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 9.4Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.4
Grade Unit
g/t
Intercept
0.85 m
From
150.55 m
To
151.4 m
Intercept Depth
150.55 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:150.55-151.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
12.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 9.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.0 g/t·m is below.

Negative factors

  • 9.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.4”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.064Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.064
Grade Unit
g/t
Intercept
0.5 m
From
172.1 m
To
172.6 m
Intercept Depth
172.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:172.1-172.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.064 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.064 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.064”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 9.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
9.4
Grade Unit
g/t
Intercept
0.5 m
From
172.1 m
To
172.6 m
Intercept Depth
172.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:172.1-172.6
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
13.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 9.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.7 g/t·m is below.

Negative factors

  • 9.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“9.4”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.022Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.022
Grade Unit
g/t
Intercept
1 m
From
208 m
To
209 m
Intercept Depth
208 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:208-209
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.022 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.022 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.022”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 6.2Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.2
Grade Unit
g/t
Intercept
1 m
From
208 m
To
209 m
Intercept Depth
208 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:208-209
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.2 g/t·m is below.

Negative factors

  • 6.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.2”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.023Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.023
Grade Unit
g/t
Intercept
0.85 m
From
243.15 m
To
244 m
Intercept Depth
243.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:243.15-244
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.023 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.023 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.023”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 8.4Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.4
Grade Unit
g/t
Intercept
0.85 m
From
243.15 m
To
244 m
Intercept Depth
243.15 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:243.15-244
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 8.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 7.1 g/t·m is below.

Negative factors

  • 8.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.4”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.038Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.038
Grade Unit
g/t
Intercept
0.9 m
From
266.25 m
To
267.15 m
Intercept Depth
266.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:266.25-267.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.038 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.038 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.038”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 7.2Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.2
Grade Unit
g/t
Intercept
0.9 m
From
266.25 m
To
267.15 m
Intercept Depth
266.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:266.25-267.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 7.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.5 g/t·m is below.

Negative factors

  • 7.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.2”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.139Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.139
Grade Unit
g/t
Intercept
0.5 m
From
300.9 m
To
301.4 m
Intercept Depth
300.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:300.9-301.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
46.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.139 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.139 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.139”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 36.9Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
36.9
Grade Unit
g/t
Intercept
0.5 m
From
300.9 m
To
301.4 m
Intercept Depth
300.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:300.9-301.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
46.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 36.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 18.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“36.9”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.03Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.5 m
From
301.9 m
To
302.4 m
Intercept Depth
301.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:301.9-302.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 6.3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6.3
Grade Unit
g/t
Intercept
0.5 m
From
301.9 m
To
302.4 m
Intercept Depth
301.9 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:301.9-302.4
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.1 g/t·m is below.

Negative factors

  • 6.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.3”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · goldGrade: 0.242Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.242
Grade Unit
g/t
Intercept
0.5 m
From
302.4 m
To
302.9 m
Intercept Depth
302.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:302.4-302.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
62.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.242 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.242 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.242”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-006Copalquin · silverGrade: 45.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-006
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
45.2
Grade Unit
g/t
Intercept
0.5 m
From
302.4 m
To
302.9 m
Intercept Depth
302.4 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-006:302.4-302.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
62.1
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 45.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 22.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“45.2”

Context: AP25-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.033Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.033
Grade Unit
g/t
Intercept
1 m
From
29 m
To
30 m
Intercept Depth
29 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:29-30
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.033 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.033 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.033”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 6Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
6
Grade Unit
g/t
Intercept
1 m
From
29 m
To
30 m
Intercept Depth
29 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:29-30
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.3
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.0 g/t·m is below.

Negative factors

  • 6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.049Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.049
Grade Unit
g/t
Intercept
0.75 m
From
50.25 m
To
51 m
Intercept Depth
50.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:50.25-51
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.049 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.049 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.049”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 8Grade Unit: g/tIntercept: 0.75 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8
Grade Unit
g/t
Intercept
0.75 m
From
50.25 m
To
51 m
Intercept Depth
50.25 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:50.25-51
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.0 g/t·m is below.

Negative factors

  • 8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.067Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.067
Grade Unit
g/t
Intercept
1 m
From
51 m
To
52 m
Intercept Depth
51 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:51-52
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
19.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.067 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.067 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.067”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 15.2Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
15.2
Grade Unit
g/t
Intercept
1 m
From
51 m
To
52 m
Intercept Depth
51 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:51-52
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
19.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 15.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 15.2 g/t·m is below.

Negative factors

  • 15.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“15.2”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.554Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.554
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:52-52.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
77.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.554 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.554”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 39Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
39
Grade Unit
g/t
Intercept
0.5 m
From
52 m
To
52.5 m
Intercept Depth
52 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:52-52.5
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
77.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 39 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 19.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“39”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.095Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.095
Grade Unit
g/t
Intercept
0.5 m
From
57.85 m
To
58.35 m
Intercept Depth
57.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:57.85-58.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.095 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.095 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.095”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 10.1Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
10.1
Grade Unit
g/t
Intercept
0.5 m
From
57.85 m
To
58.35 m
Intercept Depth
57.85 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:57.85-58.35
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
16.8
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 10.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 5.0 g/t·m is below.

Negative factors

  • 10.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“10.1”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.025Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.025
Grade Unit
g/t
Intercept
0.8 m
From
60.1 m
To
60.9 m
Intercept Depth
60.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:60.1-60.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.025 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.025 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.025”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 8.1Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.1
Grade Unit
g/t
Intercept
0.8 m
From
60.1 m
To
60.9 m
Intercept Depth
60.1 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:60.1-60.9
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.9
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 8.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.5 g/t·m is below.

Negative factors

  • 8.1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.1”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.13Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.13
Grade Unit
g/t
Intercept
0.55 m
From
62.75 m
To
63.3 m
Intercept Depth
62.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:62.75-63.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
49.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.13 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.13”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 40.1Grade Unit: g/tIntercept: 0.55 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
40.1
Grade Unit
g/t
Intercept
0.55 m
From
62.75 m
To
63.3 m
Intercept Depth
62.75 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:62.75-63.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
49.2
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 40.1 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 22.1 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“40.1”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.033Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.033
Grade Unit
g/t
Intercept
0.5 m
From
63.8 m
To
64.3 m
Intercept Depth
63.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:63.8-64.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.033 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.033 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.033”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 5.3Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.3
Grade Unit
g/t
Intercept
0.5 m
From
63.8 m
To
64.3 m
Intercept Depth
63.8 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:63.8-64.3
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.6
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.6 g/t·m is below.

Negative factors

  • 5.3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.3”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.044Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.044
Grade Unit
g/t
Intercept
0.85 m
From
67 m
To
67.85 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:67-67.85
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.044 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.044 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.044”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 7.9Grade Unit: g/tIntercept: 0.85 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
7.9
Grade Unit
g/t
Intercept
0.85 m
From
67 m
To
67.85 m
Intercept Depth
67 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:67-67.85
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
11
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 7.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.7 g/t·m is below.

Negative factors

  • 7.9 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“7.9”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.024Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.024
Grade Unit
g/t
Intercept
0.65 m
From
73 m
To
73.65 m
Intercept Depth
73 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:73-73.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.024 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.024 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.024”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 5.7Grade Unit: g/tIntercept: 0.65 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.7
Grade Unit
g/t
Intercept
0.65 m
From
73 m
To
73.65 m
Intercept Depth
73 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:73-73.65
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
7.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.7 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.7 g/t·m is below.

Negative factors

  • 5.7 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.7”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.184Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.184
Grade Unit
g/t
Intercept
0.5 m
From
73.65 m
To
74.15 m
Intercept Depth
73.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:73.65-74.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
41.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.184 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.184 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.184”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 28.8Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
28.8
Grade Unit
g/t
Intercept
0.5 m
From
73.65 m
To
74.15 m
Intercept Depth
73.65 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:73.65-74.15
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
41.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 28.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.4 g/t·m is below.

Negative factors

  • 28.8 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“28.8”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · goldGrade: 0.088Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.088
Grade Unit
g/t
Intercept
0.5 m
From
93.95 m
To
94.45 m
Intercept Depth
93.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:93.95-94.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.088 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.088 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.088”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-007Copalquin · silverGrade: 8.2Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-007
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
8.2
Grade Unit
g/t
Intercept
0.5 m
From
93.95 m
To
94.45 m
Intercept Depth
93.95 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-007:93.95-94.45
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
14.4
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 8.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 4.1 g/t·m is below.

Negative factors

  • 8.2 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.2”

Context: AP25-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-008Copalquin · goldGrade: 0.061Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-008
Project
Copalquin
Commodity
gold
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
0.061
Grade Unit
g/t
Intercept
0.5 m
From
81.5 m
To
82 m
Intercept Depth
81.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-008:81.5-82
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 0.061 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.061 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.061”

Context: AP25-008

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

AP25-008Copalquin · silverGrade: 5.4Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
AP25-008
Project
Copalquin
Commodity
silver
Region
mexico
Reported Region
mexico
Ticker
MSG

Geometry

Grade
5.4
Grade Unit
g/t
Intercept
0.5 m
From
81.5 m
To
82 m
Intercept Depth
81.5 m

Classification

Deposit Type
epithermal
Sample Type
drill
Group ID
AP25-008:81.5-82
Mining Method
mixed

Location

CRS
UTM/UPS WGS 84 zone 13 N

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
9.7
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Dilution Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-04T00:00:00.000Z

Reasoning: Expanded from assay table. 5.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.7 g/t·m is below.

Negative factors

  • 5.4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“5.4”

Context: AP25-008

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "At the same time, Mithril continues to advance Target 3 to drill readiness with ongoing mapping and sampling, while at T"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.