Mithril Provides Exploration Update Over Multiple Targets, Copalquin Silver-Gold Project, Mexico
Original announcement by tmx on
- Company
- Mithril Silver and Gold Limited
- Ticker
- MSG
- Exchange
- TSX
- Region
- Mexico
- Primary commodity
- Gold
- Secondary commodities
- Silver, Lead, Zinc
- Document categories
- Drill results, Resource update, Other
- Extracted
- 2026-09-18 11:02:23 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Mithril Silver and Gold Limited has provided an exploration update for its Copalquin Silver-Gold Project in Mexico, announcing high-grade silver and gold drill intercepts from the maiden program at Target 5. The company also re-stated its JORC-compliant mineral resource estimate for Target 1, which includes both Indicated and Inferred categories. An aggressive 25,000-meter drill program is planned for 2026 across the district.
Reasoning: The document reports several high-grade silver-gold intercepts from new drilling at Target 5, confirming and extending mineralization in an epithermal system. An aggressive exploration program is planned for 2026. While a resource estimate is included, it is a re-statement of a prior estimate, and true widths are not consistently provided for all new intercepts.
Positive factors
- High-grade silver and gold intercepts from new drilling at Target 5
- Confirmation and extension of mineralization in an epithermal system
- Aggressive exploration program planned for 2026
- Detailed QA/QC disclosure and QP sign-off for drill results
Negative factors
- True width not consistently stated for all drill intercepts
- Resource estimate is a re-statement of a prior, historical estimate
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 111
Extracted facts
Stored fact records: 111. Some facts used in scoring do not have a stored record.
Drill Results (111)
AP25-001Copalquin · goldGrade: 1.21Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.21
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 32 m
- To
- 32.5 m
- Hole Depth
- 351 m
- Intercept Depth
- 32 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:32-32.5
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 124
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade and width are moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“1.21”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-001Copalquin · silverGrade: 39.3Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 39.3
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 32 m
- To
- 32.5 m
- Hole Depth
- 351 m
- Intercept Depth
- 32 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:32-32.5
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 124
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade and width are moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“124”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-001Copalquin · goldGrade: 1.285Grade Unit: g/tIntercept: 0.52 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.285
- Grade Unit
- g/t
- Intercept
- 0.52 m
- From
- 279.83 m
- To
- 280.35 m
- Hole Depth
- 351 m
- Intercept Depth
- 279.83 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:279.83-280.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 257
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade and width are moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“1.285”
Context: 0.52
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-001Copalquin · silverGrade: 167Grade Unit: g/tIntercept: 0.52 mView all detailsHide details
Identity
- Hole ID
- AP25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 167
- Grade Unit
- g/t
- Intercept
- 0.52 m
- From
- 279.83 m
- To
- 280.35 m
- Hole Depth
- 351 m
- Intercept Depth
- 279.83 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-001:279.83-280.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 40 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 257
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, with a strong grade for an epithermal system, but over a narrow width. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“257”
Context: 0.52
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-002Copalquin · goldGrade: 1.26Grade Unit: g/tIntercept: 3.85 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.26
- Grade Unit
- g/t
- Intercept
- 3.85 m
- From
- 31.45 m
- To
- 35.3 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-35.3
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 131
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“1.26”
Context: 3.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-002Copalquin · silverGrade: 42.65Grade Unit: g/tIntercept: 3.85 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 42.65
- Grade Unit
- g/t
- Intercept
- 3.85 m
- From
- 31.45 m
- To
- 35.3 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-35.3
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 131
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“131”
Context: 3.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-002Copalquin · goldGrade: 7.74Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 7.74
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 31.45 m
- To
- 31.95 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-31.95
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 729
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new high-grade gold intercept from the maiden drill program at Target 5, but over a narrow width. True width is not stated.
Positive factors
- High-grade gold intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“7.74”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-002Copalquin · silverGrade: 187Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 187
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 31.45 m
- To
- 31.95 m
- Hole Depth
- 252 m
- Intercept Depth
- 31.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-002:31.45-31.95
- Mining Method
- mixed
Location
- Easting
- 287909
- Northing
- 2822588
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.01 m
- Azimuth
- 63 °
- Dip
- -53 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 729
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade silver equivalent intercept from the maiden drill program at Target 5, but over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“729”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · goldGrade: 0.393Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.393
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 34.5 m
- To
- 35 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:34.5-35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 90
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade and width are weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.393”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · silverGrade: 62.4Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 62.4
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 34.5 m
- To
- 35 m
- Hole Depth
- 285 m
- Intercept Depth
- 34.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:34.5-35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 90
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade and width are weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“90”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · goldGrade: 2.28Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 2.28
- Grade Unit
- g/t
- Intercept
- 2.75 m
- From
- 93.6 m
- To
- 96.35 m
- Hole Depth
- 285 m
- Intercept Depth
- 93.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:93.6-96.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 660
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, with a strong grade over a narrow width. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“2.28”
Context: 2.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · silverGrade: 500Grade Unit: g/tIntercept: 2.75 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 500
- Grade Unit
- g/t
- Intercept
- 2.75 m
- From
- 93.6 m
- To
- 96.35 m
- Hole Depth
- 285 m
- Intercept Depth
- 93.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:93.6-96.35
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 660
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“660”
Context: 2.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · goldGrade: 5.8Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 5.8
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 94.7 m
- To
- 95.7 m
- Hole Depth
- 285 m
- Intercept Depth
- 94.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:94.7-95.7
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1714
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade gold intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade gold intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“5.8”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · silverGrade: 1308Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1308
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 94.7 m
- To
- 95.7 m
- Hole Depth
- 285 m
- Intercept Depth
- 94.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:94.7-95.7
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1714
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“1,714”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · goldGrade: 2.89Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 2.89
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 214 m
- To
- 215.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 214 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:214-215.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 203
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, with a strong grade over a narrow width. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“2.89”
Context: 1.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · silverGrade: 0.5Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.5
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 214 m
- To
- 215.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 214 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:214-215.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 203
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“203”
Context: 1.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · goldGrade: 2.38Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 2.38
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 231.6 m
- To
- 232.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 231.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:231.6-232.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 168
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, with a strong grade over a narrow width. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“2.38”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-003Copalquin · silverGrade: 1.5Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.5
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 231.6 m
- To
- 232.3 m
- Hole Depth
- 285 m
- Intercept Depth
- 231.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-003:231.6-232.3
- Mining Method
- mixed
Location
- Easting
- 287910
- Northing
- 2822591
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 758.82 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 168
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“168”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-004Copalquin · goldGrade: 0.57Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- AP25-004
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 89.2 m
- To
- 90.65 m
- Hole Depth
- 291 m
- Intercept Depth
- 89.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-004:89.2-90.65
- Mining Method
- mixed
Location
- Easting
- 287903.2
- Northing
- 2822590
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 760.85 m
- Azimuth
- 30 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 150
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.57”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-004Copalquin · silverGrade: 109.6Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- AP25-004
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 109.6
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 89.2 m
- To
- 90.65 m
- Hole Depth
- 291 m
- Intercept Depth
- 89.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-004:89.2-90.65
- Mining Method
- mixed
Location
- Easting
- 287903.2
- Northing
- 2822590
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 760.85 m
- Azimuth
- 30 °
- Dip
- -63 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 150
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“150”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 4.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 4.05 m
- From
- 35.65 m
- To
- 39.7 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:35.65-39.7
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.19”
Context: 4.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · silverGrade: 61.5Grade Unit: g/tIntercept: 4.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 61.5
- Grade Unit
- g/t
- Intercept
- 4.05 m
- From
- 35.65 m
- To
- 39.7 m
- Hole Depth
- 381 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:35.65-39.7
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“75”
Context: 4.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · goldGrade: 0.41Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.41
- Grade Unit
- g/t
- Intercept
- 1.6 m
- From
- 36.75 m
- To
- 38.35 m
- Hole Depth
- 381 m
- Intercept Depth
- 36.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:36.75-38.35
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.41”
Context: 1.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · silverGrade: 130Grade Unit: g/tIntercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 130
- Grade Unit
- g/t
- Intercept
- 1.6 m
- From
- 36.75 m
- To
- 38.35 m
- Hole Depth
- 381 m
- Intercept Depth
- 36.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:36.75-38.35
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“159”
Context: 1.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · goldGrade: 1.71Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 90.15 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 90.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:90.15-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 366
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“1.71”
Context: 3.35
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · silverGrade: 246Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 246
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 90.15 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 90.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:90.15-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 366
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new high-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“366”
Context: 3.35
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-005Copalquin · goldGrade: 5.35Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- AP25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 5.35
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Hole Depth
- 381 m
- Intercept Depth
- 92.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-005:92.45-93.5
- Mining Method
- mixed
Location
- Easting
- 287828
- Northing
- 2822672
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 799.94 m
- Azimuth
- 35 °
- Dip
- -60 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1146
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade gold intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade gold intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“5.35”
Context: 1.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · goldGrade: 4.548Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 4.548
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 119.2 m
- To
- 120.45 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:119.2-120.45
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 727
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new high-grade gold intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- High-grade gold intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“4.548”
Context: 1.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · silverGrade: 409Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 409
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 119.2 m
- To
- 120.45 m
- Hole Depth
- 330 m
- Intercept Depth
- 119.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:119.2-120.45
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 727
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“727”
Context: 1.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · goldGrade: 2.41Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 2.41
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 138.1 m
- To
- 139 m
- Hole Depth
- 330 m
- Intercept Depth
- 138.1 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:138.1-139
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 616
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, with a strong grade over a narrow width. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“2.41”
Context: 0.9
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · silverGrade: 447Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 447
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 138.1 m
- To
- 139 m
- Hole Depth
- 330 m
- Intercept Depth
- 138.1 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:138.1-139
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 616
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new bonanza-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- Bonanza Intercept
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“616”
Context: 0.9
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · goldGrade: 1.51Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.51
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 149.75 m
- To
- 150.55 m
- Hole Depth
- 330 m
- Intercept Depth
- 149.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:149.75-150.55
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 427
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“1.51”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · silverGrade: 321Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 321
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 149.75 m
- To
- 150.55 m
- Hole Depth
- 330 m
- Intercept Depth
- 149.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:149.75-150.55
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 427
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new high-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“427”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 301.4 m
- To
- 301.9 m
- Hole Depth
- 330 m
- Intercept Depth
- 301.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:301.4-301.9
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade and width are weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.19”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-006Copalquin · silverGrade: 73Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-006
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 73
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 301.4 m
- To
- 301.9 m
- Hole Depth
- 330 m
- Intercept Depth
- 301.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-006:301.4-301.9
- Mining Method
- mixed
Location
- Easting
- 287753
- Northing
- 2822676
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 825.53 m
- Azimuth
- 44 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade and width are weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“86”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-007Copalquin · goldGrade: 0.23Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 51 m
- To
- 52.5 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:51-52.5
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 31
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.23”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-007Copalquin · silverGrade: 15.2Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 15.2
- Grade Unit
- g/t
- Intercept
- 1.5 m
- From
- 51 m
- To
- 52.5 m
- Hole Depth
- 126 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:51-52.5
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 31
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“31”
Context: 1.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-007Copalquin · goldGrade: 0.27Grade Unit: g/tIntercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 2.05 m
- From
- 62.75 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 62.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:62.75-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 107
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.27”
Context: 2.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-007Copalquin · silverGrade: 88.1Grade Unit: g/tIntercept: 2.05 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 88.1
- Grade Unit
- g/t
- Intercept
- 2.05 m
- From
- 62.75 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 62.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:62.75-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 107
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“107”
Context: 2.05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-007Copalquin · goldGrade: 0.9Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.9
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 64.3 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 64.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:64.3-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 374
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.90”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-007Copalquin · silverGrade: 311Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-007
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 311
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 64.3 m
- To
- 64.8 m
- Hole Depth
- 126 m
- Intercept Depth
- 64.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-007:64.3-64.8
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -48 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 374
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new high-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“374”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-008Copalquin · goldGrade: 0.34Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-008
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 78.2 m
- To
- 78.9 m
- Hole Depth
- 177 m
- Intercept Depth
- 78.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-008:78.2-78.9
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -77 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 36
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.34”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-008Copalquin · silverGrade: 11.9Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-008
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 11.9
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 78.2 m
- To
- 78.9 m
- Hole Depth
- 177 m
- Intercept Depth
- 78.2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-008:78.2-78.9
- Mining Method
- mixed
Location
- Easting
- 287765
- Northing
- 2822785
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 813.31 m
- Azimuth
- 30 °
- Dip
- -77 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 36
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“36”
Context: 0.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-009Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 85 m
- To
- 85.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:85-85.8
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 30
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is very low. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.09”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-009Copalquin · silverGrade: 23.6Grade Unit: g/tIntercept: 0.8 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 23.6
- Grade Unit
- g/t
- Intercept
- 0.8 m
- From
- 85 m
- To
- 85.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:85-85.8
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 30
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“30”
Context: 0.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-009Copalquin · goldGrade: 0.3Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 89.45 m
- To
- 95.55 m
- Hole Depth
- 300 m
- Intercept Depth
- 89.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:89.45-95.55
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 43
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.30”
Context: 6.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-009Copalquin · silverGrade: 21.7Grade Unit: g/tIntercept: 6.1 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 21.7
- Grade Unit
- g/t
- Intercept
- 6.1 m
- From
- 89.45 m
- To
- 95.55 m
- Hole Depth
- 300 m
- Intercept Depth
- 89.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:89.45-95.55
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 43
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“43”
Context: 6.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-009Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 99.6 m
- To
- 100.1 m
- Hole Depth
- 300 m
- Intercept Depth
- 99.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:99.6-100.1
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 18
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is very low. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.10”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-009Copalquin · silverGrade: 10.3Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-009
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 10.3
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 99.6 m
- To
- 100.1 m
- Hole Depth
- 300 m
- Intercept Depth
- 99.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-009:99.6-100.1
- Mining Method
- mixed
Location
- Easting
- 287605
- Northing
- 2822595
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 891.75 m
- Azimuth
- 45 °
- Dip
- -55 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 18
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“18”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-010Copalquin · goldGrade: 0.5Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.5
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 96 m
- To
- 96.5 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:96-96.5
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 83
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.50”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-010Copalquin · silverGrade: 47.4Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 47.4
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 96 m
- To
- 96.5 m
- Hole Depth
- 300 m
- Intercept Depth
- 96 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:96-96.5
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 83
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“83”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-010Copalquin · goldGrade: 0.45Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.45
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 241.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 443
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.45”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-010Copalquin · silverGrade: 411Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 411
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 241.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 443
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new high-grade silver equivalent intercept from the maiden drill program at Target 5, over a narrow width. True width is not stated.
Positive factors
- High-grade silver equivalent intercept
Negative factors
- Apparent width only, true width not stated
Evidence · table
“443”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-010Copalquin · leadGrade: 3.4Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 3.4
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 241.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new lead intercept from the maiden drill program at Target 5, with a strong grade over a narrow width. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · text
“plus 3.4% lead and 1.70% zinc”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-010Copalquin · zincGrade: 1.7Grade Unit: %Intercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-010
- Project
- Copalquin
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.7
- Grade Unit
- %
- Intercept
- 0.5 m
- From
- 241.3 m
- To
- 241.8 m
- Hole Depth
- 300 m
- Intercept Depth
- 241.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-010:241.3-241.8
- Mining Method
- mixed
Location
- Easting
- 287638
- Northing
- 2822483
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 854.12 m
- Azimuth
- 60 °
- Dip
- -46 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new zinc intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · text
“plus 3.4% lead and 1.70% zinc”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-011Copalquin · goldGrade: 0.06Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-011
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.06
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 263.15 m
- To
- 263.65 m
- Hole Depth
- 381 m
- Intercept Depth
- 263.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-011:263.15-263.65
- Mining Method
- mixed
Location
- Easting
- 287859
- Northing
- 2822568
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 744.79 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is very low. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.06”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-011Copalquin · silverGrade: 24Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-011
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 24
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 263.15 m
- To
- 263.65 m
- Hole Depth
- 381 m
- Intercept Depth
- 263.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-011:263.15-263.65
- Mining Method
- mixed
Location
- Easting
- 287859
- Northing
- 2822568
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 744.79 m
- Azimuth
- 63 °
- Dip
- -69 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“29”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-012Copalquin · goldGrade: 0.22Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 84.45 m
- To
- 84.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:84.45-84.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 121
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.22”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-012Copalquin · silverGrade: 105.3Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 105.3
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 84.45 m
- To
- 84.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 84.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:84.45-84.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 121
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“121”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-012Copalquin · goldGrade: 0.14Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.14
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 232.95 m
- To
- 233.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 232.95 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:232.95-233.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 115
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.14”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-012Copalquin · silverGrade: 105Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 105
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 232.95 m
- To
- 233.95 m
- Hole Depth
- 351 m
- Intercept Depth
- 232.95 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:232.95-233.95
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 115
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“115”
Context: 1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-012Copalquin · goldGrade: 0.63Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.63
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 347.05 m
- To
- 347.65 m
- Hole Depth
- 351 m
- Intercept Depth
- 347.05 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:347.05-347.65
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 130
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.63”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-012Copalquin · silverGrade: 86Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- AP25-012
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 86
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 347.05 m
- To
- 347.65 m
- Hole Depth
- 351 m
- Intercept Depth
- 347.05 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-012:347.05-347.65
- Mining Method
- mixed
Location
- Easting
- 287877
- Northing
- 2822485
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 741.56 m
- Azimuth
- 60 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 130
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is moderate for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“130”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · goldGrade: 0.05Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.05
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 73.65 m
- To
- 74.4 m
- Hole Depth
- 399 m
- Intercept Depth
- 73.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-013:73.65-74.4
- Mining Method
- mixed
Location
- Easting
- 287829
- Northing
- 2822379
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 738.95 m
- Azimuth
- 60 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is very low. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.05”
Context: 0.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · silverGrade: 15.6Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 15.6
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 73.65 m
- To
- 74.4 m
- Hole Depth
- 399 m
- Intercept Depth
- 73.65 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-013:73.65-74.4
- Mining Method
- mixed
Location
- Easting
- 287829
- Northing
- 2822379
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 738.95 m
- Azimuth
- 60 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 19
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new silver equivalent intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“19”
Context: 0.75
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · goldGrade: 0.44Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.44
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 78.75 m
- To
- 79.25 m
- Hole Depth
- 399 m
- Intercept Depth
- 78.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- AP25-013:78.75-79.25
- Mining Method
- mixed
Location
- Easting
- 287829
- Northing
- 2822379
- CRS
- UTM/UPS WGS 84 zone 13 N
- Elevation
- 738.95 m
- Azimuth
- 60 °
- Dip
- -45 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
- Max Dilution
- 2 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: This is a new gold intercept from the maiden drill program at Target 5, but the grade is weak for an epithermal system. True width is not stated.
Negative factors
- Apparent width only, true width not stated
Evidence · table
“0.44”
Context: 0.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
(IncludingCopalquin · goldGrade: 5.35Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- (Including
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 5.35
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Intercept Depth
- 92.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- (Including:92.45-93.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1146
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 5.35 g/t gold is exceptional against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.6 g/t·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 5.35 g/t gold is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.35”
Context: (Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
(IncludingCopalquin · silverGrade: 771Grade Unit: g/tIntercept: 1.05 mView all detailsHide details
Identity
- Hole ID
- (Including
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 771
- Grade Unit
- g/t
- Intercept
- 1.05 m
- From
- 92.45 m
- To
- 93.5 m
- Intercept Depth
- 92.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- (Including:92.45-93.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1146
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 771 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 809.6 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 771 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“771”
Context: (Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · silverGrade: 55.5Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 55.5
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 78.75 m
- To
- 79.25 m
- Intercept Depth
- 78.75 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:78.75-79.25
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 86
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 55.5 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 27.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“55.5”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · goldGrade: 0.16Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 384.2 m
- To
- 384.9 m
- Intercept Depth
- 384.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:384.2-384.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 15
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.16 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.16 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.16”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-013Copalquin · silverGrade: 3.8Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- AP25-013
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 3.8
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 384.2 m
- To
- 384.9 m
- Intercept Depth
- 384.2 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-013:384.2-384.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 15
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 3.8 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.7 g/t·m is below.
Negative factors
- 3.8 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.8”
Context: AP25-013
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 0.13Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 78 m
- To
- 78.55 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:78-78.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.13 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 65.9Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 65.9
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 78 m
- To
- 78.55 m
- Intercept Depth
- 78 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:78-78.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 75
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 65.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 36.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“65.9”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 1.14Grade Unit: g/tIntercept: 2.85 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.14
- Grade Unit
- g/t
- Intercept
- 2.85 m
- From
- 79.6 m
- To
- 82.45 m
- Intercept Depth
- 79.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:79.6-82.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 145
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.14 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.2 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.14”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 64.7Grade Unit: g/tIntercept: 2.85 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 64.7
- Grade Unit
- g/t
- Intercept
- 2.85 m
- From
- 79.6 m
- To
- 82.45 m
- Intercept Depth
- 79.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:79.6-82.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 145
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 64.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 184.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“64.7”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 1.4Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 1.4
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 185.5 m
- To
- 186 m
- Intercept Depth
- 185.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:185.5-186
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 163
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.4 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.40”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 64.7Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 64.7
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 185.5 m
- To
- 186 m
- Intercept Depth
- 185.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:185.5-186
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 163
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 64.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 32.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“64.7”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · goldGrade: 0.34Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 407.7 m
- To
- 408.9 m
- Intercept Depth
- 407.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:407.7-408.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 82
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.34 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.34”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-014Copalquin · silverGrade: 57.9Grade Unit: g/tIntercept: 1.2 mView all detailsHide details
Identity
- Hole ID
- AP25-014
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 57.9
- Grade Unit
- g/t
- Intercept
- 1.2 m
- From
- 407.7 m
- To
- 408.9 m
- Intercept Depth
- 407.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-014:407.7-408.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 82
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 57.9 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 69.5 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“57.9”
Context: AP25-014
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.26Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 9 m
- To
- 10 m
- Intercept Depth
- 9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:9-10
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 47
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.26 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.26 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.26”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 29.1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 29.1
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 9 m
- To
- 10 m
- Intercept Depth
- 9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:9-10
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 47
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 29.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 29.1 g/t·m is below.
Negative factors
- 29.1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“29.1”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 57.6 m
- To
- 58.1 m
- Intercept Depth
- 57.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:57.6-58.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 24
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 17.1Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 17.1
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 57.6 m
- To
- 58.1 m
- Intercept Depth
- 57.6 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:57.6-58.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 24
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 17.1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 8.6 g/t·m is below.
Negative factors
- 17.1 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“17.1”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.18Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 63 m
- To
- 63.75 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:63-63.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 32
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 19.2Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 19.2
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 63 m
- To
- 63.75 m
- Intercept Depth
- 63 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:63-63.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 32
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 19.2 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.4 g/t·m is below.
Negative factors
- 19.2 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“19.2”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 3.05 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 3.05 m
- From
- 193.05 m
- To
- 196.1 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 170
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 165Grade Unit: g/tIntercept: 3.05 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 165
- Grade Unit
- g/t
- Intercept
- 3.05 m
- From
- 193.05 m
- To
- 196.1 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 170
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 165 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 503.2 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“165”
Context: AP25-017
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.11Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 193.05 m
- To
- 193.9 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-193.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 237
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.11 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 229Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 229
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 193.05 m
- To
- 193.9 m
- Intercept Depth
- 193.05 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:193.05-193.9
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 237
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 229 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 194.7 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 229 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“229”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.65 m
- From
- 195.45 m
- To
- 196.1 m
- Intercept Depth
- 195.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:195.45-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 271
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
AP25-017Copalquin · silverGrade: 265Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- AP25-017
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 265
- Grade Unit
- g/t
- Intercept
- 0.65 m
- From
- 195.45 m
- To
- 196.1 m
- Intercept Depth
- 195.45 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- AP25-017:195.45-196.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 271
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 265 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 172.3 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 265 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“265”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 36.5 m
- To
- 37.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:36.5-37.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · silverGrade: 21.9Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 21.9
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 36.5 m
- To
- 37.5 m
- Intercept Depth
- 36.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:36.5-37.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 29
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 21.9 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 21.9 g/t·m is below.
Negative factors
- 21.9 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“21.9”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · goldGrade: 0.18Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 57.1 m
- To
- 60.45 m
- Intercept Depth
- 57.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:57.1-60.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 46
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-001Copalquin · silverGrade: 33.7Grade Unit: g/tIntercept: 3.35 mView all detailsHide details
Identity
- Hole ID
- TA25-001
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 33.7
- Grade Unit
- g/t
- Intercept
- 3.35 m
- From
- 57.1 m
- To
- 60.45 m
- Intercept Depth
- 57.1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-001:57.1-60.45
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 46
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 33.7 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 112.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“33.7”
Context: TA25-001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · goldGrade: 0.09Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 35.65 m
- To
- 36.35 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:35.65-36.35
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 41
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · silverGrade: 34.8Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 34.8
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 35.65 m
- To
- 36.35 m
- Intercept Depth
- 35.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:35.65-36.35
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 41
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 34.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 24.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“34.8”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · goldGrade: 0.19Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 77.35 m
- To
- 77.85 m
- Intercept Depth
- 77.35 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:77.35-77.85
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 66
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.19 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.19 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.19”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · silverGrade: 52.8Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 52.8
- Grade Unit
- g/t
- Intercept
- 0.5 m
- From
- 77.35 m
- To
- 77.85 m
- Intercept Depth
- 77.35 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:77.35-77.85
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 66
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 52.8 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 26.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“52.8”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · goldGrade: 0.39Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.85 m
- To
- 81.1 m
- Intercept Depth
- 79.85 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:79.85-81.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 57
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.39 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.39”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-002Copalquin · silverGrade: 29.4Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-002
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 29.4
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.85 m
- To
- 81.1 m
- Intercept Depth
- 79.85 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-002:79.85-81.1
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 57
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 29.4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 36.8 g/t·m is below.
Negative factors
- 29.4 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“29.4”
Context: TA25-002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · goldGrade: 0.07Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 33.8 m
- To
- 34.55 m
- Intercept Depth
- 33.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:33.8-34.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 26
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · silverGrade: 21.3Grade Unit: g/tIntercept: 0.75 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 21.3
- Grade Unit
- g/t
- Intercept
- 0.75 m
- From
- 33.8 m
- To
- 34.55 m
- Intercept Depth
- 33.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:33.8-34.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 26
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 21.3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.0 g/t·m is below.
Negative factors
- 21.3 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“21.3”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 45.65 m
- To
- 46.5 m
- Intercept Depth
- 45.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:45.65-46.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 45
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-003Copalquin · silverGrade: 37.4Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- TA25-003
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 37.4
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 45.65 m
- To
- 46.5 m
- Intercept Depth
- 45.65 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-003:45.65-46.5
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 45
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 37.4 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 31.8 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“37.4”
Context: TA25-003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-004Copalquin · goldGrade: 0.53Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-004
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.5 m
- To
- 80.75 m
- Intercept Depth
- 79.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-004:79.5-80.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 103
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.53 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.53”
Context: TA25-004
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-004Copalquin · silverGrade: 66.35Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TA25-004
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 66.35
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 79.5 m
- To
- 80.75 m
- Intercept Depth
- 79.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-004:79.5-80.75
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 103
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 66.35 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 82.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“66.35”
Context: TA25-004
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · goldGrade: 0.13Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 1 m
- To
- 3 m
- Intercept Depth
- 1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:1-3
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 28
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.13 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · silverGrade: 18.55Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 18.55
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 1 m
- To
- 3 m
- Intercept Depth
- 1 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:1-3
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 28
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 18.55 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 37.1 g/t·m is below.
Negative factors
- 18.55 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“18.55”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · goldGrade: 0.1Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 0.1
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 141 m
- To
- 141.55 m
- Intercept Depth
- 141 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:141-141.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 89
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.1 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TA25-005Copalquin · silverGrade: 82.2Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Hole ID
- TA25-005
- Project
- Copalquin
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- MSG
Geometry
- Grade
- 82.2
- Grade Unit
- g/t
- Intercept
- 0.55 m
- From
- 141 m
- To
- 141.55 m
- Intercept Depth
- 141 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- TA25-005:141-141.55
- Mining Method
- mixed
Location
- CRS
- UTM/UPS WGS 84 zone 13 N
QA/QC
- Laboratory
- ALS Global
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 89
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Compositing
- Dilution Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-02-11T00:00:00.000Z
Reasoning: Expanded from assay table. 82.2 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 45.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“82.2”
Context: TA25-005
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.