NiCAN Provides a Review of its March 2024 Drilling Program and Next Steps at the Wine Project, Manitoba
Original announcement by tmx on
- Company
- NiCAN Limited
- Ticker
- NICN
- Exchange
- TSX
- Region
- Manitoba
- Primary commodity
- Nickel
- Secondary commodities
- Copper, Cobalt, Platinum
- Document categories
- Drill results, Other
- Extracted
- 2026-09-14 15:32:15 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
NiCAN completed its March 2024 Phase III-B drilling program at the Wine Project in Manitoba, discovering a new near-surface zone to the north. The results confirmed strong nickel-copper grades and provided better structural understanding of the Main and Upper Zones, which appear more steeply dipping than previously modeled.
Reasoning: The program successfully identified a new zone, extended known mineralization, and returned high-grade Ni-Cu-PGM intercepts.
Positive factors
- Strong nickel and copper grades over meaningful widths
- Discovery of a new near-surface zone to the north
- Extension of mineralization to the south and at depth
- High PGM values in key intersections
Negative factors
- Some holes (Wine 24-1, Wine 24-3) had azimuths too far east to confirm specific plunge directions
Facts used in scoring: 51
Classification and evidence
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The program discovered a new near-surface zone to the north.
Evidence · text
“This program discovered a new near surface zone to the north”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release details ALS Canada Ltd laboratory, standards, blanks, and duplicates.
Evidence · text
“NiCAN submitted a regular schedule of standards, blanks and duplicates”
Extracted facts
Stored fact records: 51. Some facts used in scoring do not have a stored record.
Drill Results (51)
Wine 24-3Wine · copperGrade: 1.1Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-3
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.1
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 5.9 m
- To
- 11.4 m
- Intercept Depth
- 5.9 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-3:5.9-11.4
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.5
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: 1.1% Cu is a solid grade for this exploration stage.
Positive factors
- Strong copper grade
Evidence · text
“Wine 24-3 intersected 5.5 meters averaging 1.10% Cu”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-3Wine · nickelGrade: 1.27Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-3
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.27
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 5.9 m
- To
- 11.4 m
- Intercept Depth
- 5.9 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-3:5.9-11.4
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.5
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: 1.27% Ni is a strong grade for this type of exploration.
Positive factors
- Strong nickel grade
Evidence · text
“1.27% Ni (1.47% NiEq)”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-4Wine · copperGrade: 2.88Grade Unit: %Intercept: 20.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-4
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 2.88
- Grade Unit
- %
- Intercept
- 20.3 m
- From
- 66 m
- To
- 86.3 m
- Intercept Depth
- 66 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-4:66-86.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.78
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: 2.88% Cu over 20.3m is an exceptional intercept.
Positive factors
- High grade
- Significant width
Evidence · table
“2.88”
Context: 20.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-4Wine · nickelGrade: 2.14Grade Unit: %Intercept: 20.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-4
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 2.14
- Grade Unit
- %
- Intercept
- 20.3 m
- From
- 66 m
- To
- 86.3 m
- Intercept Depth
- 66 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-4:66-86.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.78
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: 2.14% Ni over 20.3m is a very strong intercept.
Positive factors
- High grade
- Significant width
Evidence · table
“2.14”
Context: 20.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-4Wine · platinumGrade: 1.19Grade Unit: g/tIntercept: 20.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-4
- Project
- Wine
- Commodity
- platinum
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.19
- Grade Unit
- g/t
- Intercept
- 20.3 m
- From
- 66 m
- To
- 86.3 m
- Intercept Depth
- 66 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-4:66-86.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: 1.19 g/t PGM is noted as elevated.
Positive factors
- Elevated PGM values
Evidence · table
“1.19”
Context: 20.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Wine 24-1AWine · copperGrade: 1.4Grade Unit: %Intercept: 3.7 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.4
- Grade Unit
- %
- Intercept
- 3.7 m
- From
- 7.5 m
- To
- 11.2 m
- Intercept Depth
- 7.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:7.5-11.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.49
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Discovery of a new zone to the north.
Positive factors
- New near-surface zone discovery
Evidence · table
“1.40”
Context: 3.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · nickelGrade: 1.63Grade Unit: %Intercept: 3.7 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.63
- Grade Unit
- %
- Intercept
- 3.7 m
- From
- 7.5 m
- To
- 11.2 m
- Intercept Depth
- 7.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:7.5-11.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.49
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: 1.63% Ni in a new zone.
Positive factors
- New near-surface zone discovery
Evidence · table
“1.63”
Context: 3.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · copperGrade: 0.71Grade Unit: %Intercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.71
- Grade Unit
- %
- Intercept
- 5.4 m
- From
- 6.8 m
- To
- 12.2 m
- Intercept Depth
- 6.8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:6.8-12.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.33
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.71 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 3.8 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.71”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · nickelGrade: 1.35Grade Unit: %Intercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.35
- Grade Unit
- %
- Intercept
- 5.4 m
- From
- 6.8 m
- To
- 12.2 m
- Intercept Depth
- 6.8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:6.8-12.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.33
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.35 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.35”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · cobaltGrade: 0.07Grade Unit: %Intercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 5.4 m
- From
- 6.8 m
- To
- 12.2 m
- Intercept Depth
- 6.8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:6.8-12.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.33
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.07 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · copperGrade: 0.76Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.76
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 23.5 m
- To
- 29 m
- Intercept Depth
- 23.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:23.5-29
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.84
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.76 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 4.2 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.76”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · nickelGrade: 1.58Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.58
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 23.5 m
- To
- 29 m
- Intercept Depth
- 23.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:23.5-29
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.84
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.58 % nickel is strong against the default band [3, 1.5, 0.8, 0.3] %.
Positive factors
- 1.58 % nickel is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.58”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · cobaltGrade: 0.07Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 23.5 m
- To
- 29 m
- Intercept Depth
- 23.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:23.5-29
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.84
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.07 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · copperGrade: 0.92Grade Unit: %Intercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.92
- Grade Unit
- %
- Intercept
- 4.6 m
- From
- 41.6 m
- To
- 46.2 m
- Intercept Depth
- 41.6 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:41.6-46.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.81
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.92 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 4.2 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.92”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · nickelGrade: 1Grade Unit: %Intercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1
- Grade Unit
- %
- Intercept
- 4.6 m
- From
- 41.6 m
- To
- 46.2 m
- Intercept Depth
- 41.6 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:41.6-46.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.81
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.00”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1Wine · cobaltGrade: 0.05Grade Unit: %Intercept: 4.6 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 4.6 m
- From
- 41.6 m
- To
- 46.2 m
- Intercept Depth
- 41.6 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1:41.6-46.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.81
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.05 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: Wine 24-1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · cobaltGrade: 0.08Grade Unit: %Intercept: 3.7 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.08
- Grade Unit
- %
- Intercept
- 3.7 m
- From
- 7.5 m
- To
- 11.2 m
- Intercept Depth
- 7.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:7.5-11.2
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.49
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.08 % cobalt is weak against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.08”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · copperGrade: 0.55Grade Unit: %Intercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.55
- Grade Unit
- %
- Intercept
- 1.6 m
- From
- 24.8 m
- To
- 26.4 m
- Intercept Depth
- 24.8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:24.8-26.4
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.68
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.55 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.9 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.55”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · nickelGrade: 0.6Grade Unit: %Intercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 1.6 m
- From
- 24.8 m
- To
- 26.4 m
- Intercept Depth
- 24.8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:24.8-26.4
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.68
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.6 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.60”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · cobaltGrade: 0.03Grade Unit: %Intercept: 1.6 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 1.6 m
- From
- 24.8 m
- To
- 26.4 m
- Intercept Depth
- 24.8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:24.8-26.4
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.68
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.03 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · copperGrade: 1.2Grade Unit: %Intercept: 45.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.2
- Grade Unit
- %
- Intercept
- 45.5 m
- From
- 29.7 m
- To
- 75.1 m
- Intercept Depth
- 29.7 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:29.7-75.1
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.69
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.2 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 54.6 %·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 1.2 % copper is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.20”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · nickelGrade: 1.32Grade Unit: %Intercept: 45.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.32
- Grade Unit
- %
- Intercept
- 45.5 m
- From
- 29.7 m
- To
- 75.1 m
- Intercept Depth
- 29.7 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:29.7-75.1
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.69
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.32 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.32”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-1AWine · cobaltGrade: 0.06Grade Unit: %Intercept: 45.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-1A
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 45.5 m
- From
- 29.7 m
- To
- 75.1 m
- Intercept Depth
- 29.7 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-1A:29.7-75.1
Location
- Location
- Main Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.69
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.06 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: Wine 24-1A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · copperGrade: 1.25Grade Unit: %Intercept: 28 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.25
- Grade Unit
- %
- Intercept
- 28 m
- From
- 76.5 m
- To
- 104.5 m
- Intercept Depth
- 76.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:76.5-104.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.25
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.25 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 35.0 %·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 1.25 % copper is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.25”
Context: Wine 24-2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · nickelGrade: 0.59Grade Unit: %Intercept: 28 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 28 m
- From
- 76.5 m
- To
- 104.5 m
- Intercept Depth
- 76.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:76.5-104.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.25
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.59 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.59”
Context: Wine 24-2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · cobaltGrade: 0.02Grade Unit: %Intercept: 28 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 28 m
- From
- 76.5 m
- To
- 104.5 m
- Intercept Depth
- 76.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:76.5-104.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.25
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.02 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: Wine 24-2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · copperGrade: 1.99Grade Unit: %Intercept: 6.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.99
- Grade Unit
- %
- Intercept
- 6.5 m
- From
- 76.5 m
- To
- 83 m
- Intercept Depth
- 76.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:76.5-83
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.2
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.99 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 12.9 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 1.99 % copper is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.99”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · nickelGrade: 1.24Grade Unit: %Intercept: 6.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.24
- Grade Unit
- %
- Intercept
- 6.5 m
- From
- 76.5 m
- To
- 83 m
- Intercept Depth
- 76.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:76.5-83
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.2
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.24 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.24”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · cobaltGrade: 0.04Grade Unit: %Intercept: 6.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 6.5 m
- From
- 76.5 m
- To
- 83 m
- Intercept Depth
- 76.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:76.5-83
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.2
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.04 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · copperGrade: 1.23Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.23
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 87 m
- To
- 104.5 m
- Intercept Depth
- 87 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:87-104.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.96
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.23 % copper is strong against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 21.5 %·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 1.23 % copper is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.23”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · nickelGrade: 0.45Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.45
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 87 m
- To
- 104.5 m
- Intercept Depth
- 87 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:87-104.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.96
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.45 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.45”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-2Wine · cobaltGrade: 0.02Grade Unit: %Intercept: 17.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-2
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 17.5 m
- From
- 87 m
- To
- 104.5 m
- Intercept Depth
- 87 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-2:87-104.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.96
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.02 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.02 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.02”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-3Wine · cobaltGrade: 0.06Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- Wine 24-3
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 5.5 m
- From
- 5.9 m
- To
- 11.4 m
- Intercept Depth
- 5.9 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-3:5.9-11.4
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.5
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.06 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: Wine 24-3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-3Wine · copperGrade: 0.48Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-3
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.48
- Grade Unit
- %
- Intercept
- 3 m
- From
- 30.5 m
- To
- 33.5 m
- Intercept Depth
- 30.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-3:30.5-33.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.97
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.48 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.4 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.48”
Context: Wine 24-3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-3Wine · nickelGrade: 0.28Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-3
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 3 m
- From
- 30.5 m
- To
- 33.5 m
- Intercept Depth
- 30.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-3:30.5-33.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.97
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.28 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.28 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.28”
Context: Wine 24-3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-3Wine · cobaltGrade: 0.03Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-3
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 3 m
- From
- 30.5 m
- To
- 33.5 m
- Intercept Depth
- 30.5 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-3:30.5-33.5
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.97
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.03 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: Wine 24-3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-4Wine · cobaltGrade: 0.09Grade Unit: %Intercept: 20.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-4
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.09
- Grade Unit
- %
- Intercept
- 20.3 m
- From
- 66 m
- To
- 86.3 m
- Intercept Depth
- 66 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-4:66-86.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6.78
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 % cobalt is weak against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: Wine 24-4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · nickelGrade: 0.05Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 2 m
- From
- 8 m
- To
- 10 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:8-10
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.67
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.05 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · cobaltGrade: 0.01Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 2 m
- From
- 8 m
- To
- 10 m
- Intercept Depth
- 8 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:8-10
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 0.67
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.01 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · copperGrade: 0.9Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.9
- Grade Unit
- %
- Intercept
- 3 m
- From
- 12 m
- To
- 15 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:12-15
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.82
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.9 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.7 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.90”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · nickelGrade: 1.51Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.51
- Grade Unit
- %
- Intercept
- 3 m
- From
- 12 m
- To
- 15 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:12-15
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.82
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.51 % nickel is strong against the default band [3, 1.5, 0.8, 0.3] %.
Positive factors
- 1.51 % nickel is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.51”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · cobaltGrade: 0.07Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 3 m
- From
- 12 m
- To
- 15 m
- Intercept Depth
- 12 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:12-15
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.82
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.07 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · copperGrade: 0.64Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.64
- Grade Unit
- %
- Intercept
- 3.3 m
- From
- 28.9 m
- To
- 32.2 m
- Intercept Depth
- 28.9 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:28.9-32.2
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.08
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.64 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.1 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.64”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · nickelGrade: 0.76Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.76
- Grade Unit
- %
- Intercept
- 3.3 m
- From
- 28.9 m
- To
- 32.2 m
- Intercept Depth
- 28.9 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:28.9-32.2
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.08
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.76 % nickel is weak against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.76”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · cobaltGrade: 0.03Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 3.3 m
- From
- 28.9 m
- To
- 32.2 m
- Intercept Depth
- 28.9 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:28.9-32.2
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.08
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.03 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · copperGrade: 0.67Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.67
- Grade Unit
- %
- Intercept
- 3.9 m
- From
- 69.4 m
- To
- 73.3 m
- Intercept Depth
- 69.4 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:69.4-73.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.12
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.67 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.6 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.67”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · nickelGrade: 0.27Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 3.9 m
- From
- 69.4 m
- To
- 73.3 m
- Intercept Depth
- 69.4 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:69.4-73.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.12
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 % nickel is below against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- 0.27 % nickel is below the weak threshold (0.3 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · cobaltGrade: 0.01Grade Unit: %Intercept: 3.9 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 3.9 m
- From
- 69.4 m
- To
- 73.3 m
- Intercept Depth
- 69.4 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:69.4-73.3
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.12
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.01 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · copperGrade: 0.38Grade Unit: %Intercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- copper
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.38
- Grade Unit
- %
- Intercept
- 3.8 m
- From
- 80.2 m
- To
- 84 m
- Intercept Depth
- 80.2 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:80.2-84
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.43
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.38 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 1.4 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.38”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · nickelGrade: 1.04Grade Unit: %Intercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- nickel
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 1.04
- Grade Unit
- %
- Intercept
- 3.8 m
- From
- 80.2 m
- To
- 84 m
- Intercept Depth
- 80.2 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:80.2-84
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.43
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 1.04 % nickel is moderate against the default band [3, 1.5, 0.8, 0.3] %.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.04”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
Wine 24-7Wine · cobaltGrade: 0.04Grade Unit: %Intercept: 3.8 mView all detailsHide details
Identity
- Hole ID
- Wine 24-7
- Project
- Wine
- Commodity
- cobalt
- Region
- canada_mb
- Reported Region
- canada_mb
- Ticker
- NICN
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 3.8 m
- From
- 80.2 m
- To
- 84 m
- Intercept Depth
- 80.2 m
Classification
- Sample Type
- drill
- Group ID
- Wine 24-7:80.2-84
Location
- Location
- Upper Zone
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 2.43
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2024-05-29T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % cobalt is below against the default band [0.5, 0.3, 0.15, 0.08] %.
Negative factors
- 0.04 % cobalt is below the weak threshold (0.08 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: Wine 24-7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.