Nine Mile Metals DDH WD-26-11 Intersects 2 High Grade VMS Zones Over 27.6M Including 3.08% CU-EQ Over 10.70M, 3.27% CU-EQ Over 9.30M and 4.30% CU-EQ Over 5.0M

Original announcement by accesswire on

Company
Nine Mile Metals Ltd.
Ticker
NINE
Exchange
Unavailable
Region
New Brunswick
Primary commodity
Copper
Secondary commodities
Silver, Gold, Lead, Zinc
Document categories
Drill results
Extracted
2026-09-21 13:18:49 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Nine Mile Metals announced high-grade polymetallic VMS drill results from DDH WD-26-11 at its Wedge Critical Minerals Project in New Brunswick. The hole intersected two distinct mineralized zones, including 3.08% Cu-Eq over 10.70m, 3.27% Cu-Eq over 9.30m, and 4.30% Cu-Eq over 5.0m. The company confirmed the true width of the intervals and disclosed robust QA/QC protocols.

Reasoning: The drill results from DDH WD-26-11 show high-grade polymetallic VMS mineralization with significant copper equivalent values over substantial widths, confirming the robust nature of the Wedge project. The disclosure of true widths and comprehensive QA/QC adds confidence to the results. The presence of a void is noted but does not detract significantly from the overall positive outcome.

Positive factors

  • High-grade VMS mineralization intersected in two distinct zones
  • Significant copper equivalent grades, including 4.30% Cu-Eq over 5.0m
  • True width of intervals stated
  • Polymetallic nature of the deposit with increasing silver and gold at depth
  • QA/QC procedures disclosed and reviewed by a Qualified Person

Negative factors

  • Presence of a void in the upper zone, indicating a potential gap in mineralization or a historical mining activity

Facts used in scoring: 182

Extracted facts

Stored fact records: 182. Some facts used in scoring do not have a stored record.

Drill Results (182)

WD-26-11Wedge Critical Minerals · silverGrade: 31.98Grade Unit: g/tIntercept: 9.3 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
31.98
Grade Unit
g/t
Intercept
9.3 m
True Width
9.3 m
From
89.9 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:89.9-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This silver grade is part of a high-grade polymetallic VMS intercept, contributing to the overall value of the zone. The disclosure of true width adds confidence.

Positive factors

  • High silver grade for the interval
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“31.98”

Context: 9.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.34Grade Unit: g/tIntercept: 9.3 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.34
Grade Unit
g/t
Intercept
9.3 m
True Width
9.3 m
From
89.9 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:89.9-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The gold grade, while not exceptional on its own, adds to the polymetallic value of the VMS intercept. True width disclosure is a positive.

Positive factors

  • Gold grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.34”

Context: 9.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 2.38Grade Unit: %Intercept: 9.3 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.38
Grade Unit
%
Intercept
9.3 m
True Width
9.3 m
From
89.9 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:89.9-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This copper grade is strong for a VMS deposit and contributes significantly to the overall copper equivalent value. The true width disclosure is positive.

Positive factors

  • Strong copper grade for VMS deposit type
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“2.38”

Context: 9.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.12Grade Unit: %Intercept: 9.3 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.12
Grade Unit
%
Intercept
9.3 m
True Width
9.3 m
From
89.9 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:89.9-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The lead grade is present and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.12”

Context: 9.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.1Grade Unit: %Intercept: 9.3 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.1
Grade Unit
%
Intercept
9.3 m
True Width
9.3 m
From
89.9 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:89.9-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The zinc grade is present and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.10”

Context: 9.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 48.1Grade Unit: g/tIntercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
48.1
Grade Unit
g/t
Intercept
4.2 m
True Width
4.2 m
From
95 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:95-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This higher-grade silver sub-interval enhances the overall value of the upper zone. True width disclosure is positive.

Positive factors

  • Higher silver grade within the broader interval
  • True width disclosed

Evidence · table

“48.10”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.4Grade Unit: g/tIntercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
4.2 m
True Width
4.2 m
From
95 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:95-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The gold grade, while not exceptional on its own, adds to the polymetallic value of the VMS intercept. True width disclosure is a positive.

Positive factors

  • Gold grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.40”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 2.92Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.92
Grade Unit
%
Intercept
4.2 m
True Width
4.2 m
From
95 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:95-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This copper grade is strong for a VMS deposit and contributes significantly to the overall copper equivalent value. The true width disclosure is positive.

Positive factors

  • Strong copper grade for VMS deposit type
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“2.92”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.14Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.14
Grade Unit
%
Intercept
4.2 m
True Width
4.2 m
From
95 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:95-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The lead grade is present and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.14”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.14Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.14
Grade Unit
%
Intercept
4.2 m
True Width
4.2 m
From
95 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:95-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The zinc grade is present and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.14”

Context: 4.20

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 29Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
29
Grade Unit
g/t
Intercept
0.5 m
True Width
0.5 m
From
102.9 m
To
103.4 m
Hole Depth
149 m
Intercept Depth
102.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:102.9-103.4
Mining Method
unknown

Location

Location
Upper Zone Below Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.37
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This silver grade is part of a high-grade polymetallic VMS intercept, contributing to the overall value of the zone. The disclosure of true width adds confidence.

Positive factors

  • Good silver grade for the interval
  • True width disclosed

Evidence · table

“29.00”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.29Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.29
Grade Unit
g/t
Intercept
0.5 m
True Width
0.5 m
From
102.9 m
To
103.4 m
Hole Depth
149 m
Intercept Depth
102.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:102.9-103.4
Mining Method
unknown

Location

Location
Upper Zone Below Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The gold grade, while not exceptional on its own, adds to the polymetallic value of the VMS intercept. True width disclosure is a positive.

Positive factors

  • Gold grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.29”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 3.57Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
3.57
Grade Unit
%
Intercept
0.5 m
True Width
0.5 m
From
102.9 m
To
103.4 m
Hole Depth
149 m
Intercept Depth
102.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:102.9-103.4
Mining Method
unknown

Location

Location
Upper Zone Below Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.37
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This copper grade is strong for a VMS deposit and contributes significantly to the overall copper equivalent value. The true width disclosure is positive.

Positive factors

  • Strong copper grade for VMS deposit type
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“3.57”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.21Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.21
Grade Unit
%
Intercept
0.5 m
True Width
0.5 m
From
102.9 m
To
103.4 m
Hole Depth
149 m
Intercept Depth
102.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:102.9-103.4
Mining Method
unknown

Location

Location
Upper Zone Below Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.37
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The lead grade is present and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.21”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.11Grade Unit: %Intercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.11
Grade Unit
%
Intercept
0.5 m
True Width
0.5 m
From
102.9 m
To
103.4 m
Hole Depth
149 m
Intercept Depth
102.9 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:102.9-103.4
Mining Method
unknown

Location

Location
Upper Zone Below Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.37
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The zinc grade is present and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.11”

Context: 0.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 51.86Grade Unit: g/tIntercept: 10.7 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
51.86
Grade Unit
g/t
Intercept
10.7 m
True Width
10.7 m
From
110.5 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:110.5-121.2
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This silver grade is part of a high-grade polymetallic VMS intercept, contributing to the overall value of the zone. The disclosure of true width adds confidence.

Positive factors

  • High silver grade for the interval
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“51.86”

Context: 10.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.44Grade Unit: g/tIntercept: 10.7 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.44
Grade Unit
g/t
Intercept
10.7 m
True Width
10.7 m
From
110.5 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:110.5-121.2
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The gold grade, while not exceptional on its own, adds to the polymetallic value of the VMS intercept. True width disclosure is a positive.

Positive factors

  • Gold grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.44”

Context: 10.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.21Grade Unit: %Intercept: 10.7 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.21
Grade Unit
%
Intercept
10.7 m
True Width
10.7 m
From
110.5 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:110.5-121.2
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This copper grade is strong for a VMS deposit and contributes significantly to the overall copper equivalent value. The true width disclosure is positive.

Positive factors

  • Strong copper grade for VMS deposit type
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“1.21”

Context: 10.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 1.7Grade Unit: %Intercept: 10.7 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.7
Grade Unit
%
Intercept
10.7 m
True Width
10.7 m
From
110.5 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:110.5-121.2
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The lead grade is significant and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Significant lead grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“1.70”

Context: 10.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 1.44Grade Unit: %Intercept: 10.7 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.44
Grade Unit
%
Intercept
10.7 m
True Width
10.7 m
From
110.5 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:110.5-121.2
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The zinc grade is significant and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Significant zinc grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“1.44”

Context: 10.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 72.6Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
72.6
Grade Unit
g/t
Intercept
5 m
True Width
5 m
From
114.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:114.5-119.5
Mining Method
unknown

Location

Location
Lower Zone Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This very high-grade silver sub-interval significantly enhances the overall value of the lower zone. True width disclosure is positive.

Positive factors

  • Very high silver grade within the broader interval
  • True width disclosed

Evidence · table

“72.60”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.57Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.57
Grade Unit
g/t
Intercept
5 m
True Width
5 m
From
114.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:114.5-119.5
Mining Method
unknown

Location

Location
Lower Zone Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The gold grade, while not exceptional on its own, adds to the polymetallic value of the VMS intercept. True width disclosure is a positive.

Positive factors

  • Higher gold grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“0.57”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.5Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.5
Grade Unit
%
Intercept
5 m
True Width
5 m
From
114.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:114.5-119.5
Mining Method
unknown

Location

Location
Lower Zone Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This copper grade is strong for a VMS deposit and contributes significantly to the overall copper equivalent value. The true width disclosure is positive.

Positive factors

  • Strong copper grade for VMS deposit type
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · table

“1.50”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 2.74Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.74
Grade Unit
%
Intercept
5 m
True Width
5 m
From
114.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:114.5-119.5
Mining Method
unknown

Location

Location
Lower Zone Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The lead grade is significant and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Significant lead grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“2.74”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 2.69Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.69
Grade Unit
%
Intercept
5 m
True Width
5 m
From
114.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:114.5-119.5
Mining Method
unknown

Location

Location
Lower Zone Including
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The zinc grade is significant and contributes to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Significant zinc grade contributes to polymetallic nature
  • True width disclosed

Evidence · table

“2.69”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 87Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
87
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
116.5 m
To
117.5 m
Hole Depth
149 m
Intercept Depth
116.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:116.5-117.5
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
5.68
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This very high-grade silver sample is a highlight within the lower zone, indicating strong mineralization. True width disclosure is positive.

Positive factors

  • Very high silver grade for the interval
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · text

“Sample # 396531 returned (87 g/t Ag, 0.85 g/t Au, 1.06% Cu, 4.33% Pb, 6.75% Zn) 5.68% CuEq.”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.85Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.85
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
116.5 m
To
117.5 m
Hole Depth
149 m
Intercept Depth
116.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:116.5-117.5
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This gold grade, while not exceptional on its own, adds to the polymetallic value of the VMS intercept. True width disclosure is a positive.

Positive factors

  • Higher gold grade contributes to polymetallic nature
  • True width disclosed

Evidence · text

“Sample # 396531 returned (87 g/t Ag, 0.85 g/t Au, 1.06% Cu, 4.33% Pb, 6.75% Zn) 5.68% CuEq.”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.06Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.06
Grade Unit
%
Intercept
1 m
True Width
1 m
From
116.5 m
To
117.5 m
Hole Depth
149 m
Intercept Depth
116.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:116.5-117.5
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
5.68
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This copper grade is strong for a VMS deposit and contributes significantly to the overall copper equivalent value. The true width disclosure is positive.

Positive factors

  • Strong copper grade for VMS deposit type
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · text

“Sample # 396531 returned (87 g/t Ag, 0.85 g/t Au, 1.06% Cu, 4.33% Pb, 6.75% Zn) 5.68% CuEq.”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 4.33Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
4.33
Grade Unit
%
Intercept
1 m
True Width
1 m
From
116.5 m
To
117.5 m
Hole Depth
149 m
Intercept Depth
116.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:116.5-117.5
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
5.68
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The lead grade is very high and contributes significantly to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Very high lead grade contributes to polymetallic nature
  • True width disclosed

Evidence · text

“Sample # 396531 returned (87 g/t Ag, 0.85 g/t Au, 1.06% Cu, 4.33% Pb, 6.75% Zn) 5.68% CuEq.”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 6.75Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
6.75
Grade Unit
%
Intercept
1 m
True Width
1 m
From
116.5 m
To
117.5 m
Hole Depth
149 m
Intercept Depth
116.5 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
WD-26-11:116.5-117.5
Mining Method
unknown

Location

Location
Lower Zone
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
5.68
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: The zinc grade is very high and contributes significantly to the polymetallic nature of the VMS mineralization. True width disclosure is positive.

Positive factors

  • Very high zinc grade contributes to polymetallic nature
  • True width disclosed

Evidence · text

“Sample # 396531 returned (87 g/t Ag, 0.85 g/t Au, 1.06% Cu, 4.33% Pb, 6.75% Zn) 5.68% CuEq.”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.016Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.016
Grade Unit
g/t
Intercept
1.5 m
True Width
1.5 m
From
86.5 m
To
88 m
Hole Depth
149 m
Intercept Depth
86.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:86.5-88
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.016 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.016 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.016”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.01Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
86.5 m
To
88 m
Hole Depth
149 m
Intercept Depth
86.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:86.5-88
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
86.5 m
To
88 m
Hole Depth
149 m
Intercept Depth
86.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:86.5-88
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.01Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
86.5 m
To
88 m
Hole Depth
149 m
Intercept Depth
86.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:86.5-88
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.016Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.016
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
88 m
To
89 m
Hole Depth
149 m
Intercept Depth
88 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:88-89
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.016 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.016 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.016”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.04Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.04
Grade Unit
%
Intercept
1 m
True Width
1 m
From
88 m
To
89 m
Hole Depth
149 m
Intercept Depth
88 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:88-89
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.04 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1 m
True Width
1 m
From
88 m
To
89 m
Hole Depth
149 m
Intercept Depth
88 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:88-89
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
88 m
To
89 m
Hole Depth
149 m
Intercept Depth
88 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:88-89
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.017Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.017
Grade Unit
g/t
Intercept
0.9 m
True Width
0.9 m
From
89 m
To
89.9 m
Hole Depth
149 m
Intercept Depth
89 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89-89.9
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.017 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.017 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.017”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.02Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.02
Grade Unit
%
Intercept
0.9 m
True Width
0.9 m
From
89 m
To
89.9 m
Hole Depth
149 m
Intercept Depth
89 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89-89.9
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.02 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
0.9 m
True Width
0.9 m
From
89 m
To
89.9 m
Hole Depth
149 m
Intercept Depth
89 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89-89.9
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.01Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
0.9 m
True Width
0.9 m
From
89 m
To
89.9 m
Hole Depth
149 m
Intercept Depth
89 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89-89.9
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 14Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
14
Grade Unit
g/t
Intercept
2.1 m
True Width
2.1 m
From
89.9 m
To
92 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89.9-92
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.7
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 14 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 29.4 g/t·m is below.

Negative factors

  • 14 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“14”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.242Grade Unit: g/tIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.242
Grade Unit
g/t
Intercept
2.1 m
True Width
2.1 m
From
89.9 m
To
92 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89.9-92
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.7
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.242 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below.

Negative factors

  • 0.242 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.242”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 2.21Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.21
Grade Unit
%
Intercept
2.1 m
True Width
2.1 m
From
89.9 m
To
92 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89.9-92
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.7
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2.21 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 4.6 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.21 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.21”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.1Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.1
Grade Unit
%
Intercept
2.1 m
True Width
2.1 m
From
89.9 m
To
92 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89.9-92
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.7
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.05Grade Unit: %Intercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.05
Grade Unit
%
Intercept
2.1 m
True Width
2.1 m
From
89.9 m
To
92 m
Hole Depth
149 m
Intercept Depth
89.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:89.9-92
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.7
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.05 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 16Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
16
Grade Unit
g/t
Intercept
1.5 m
True Width
1.5 m
From
92 m
To
93.5 m
Hole Depth
149 m
Intercept Depth
92 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:92-93.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 16 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 24.0 g/t·m is below.

Negative factors

  • 16 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“16”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.31Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.31
Grade Unit
g/t
Intercept
1.5 m
True Width
1.5 m
From
92 m
To
93.5 m
Hole Depth
149 m
Intercept Depth
92 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:92-93.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.31 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.31”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.52Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.52
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
92 m
To
93.5 m
Hole Depth
149 m
Intercept Depth
92 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:92-93.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.52 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.3 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.52 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.52”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.12Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.12
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
92 m
To
93.5 m
Hole Depth
149 m
Intercept Depth
92 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:92-93.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.12 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.12”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.06Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.06
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
92 m
To
93.5 m
Hole Depth
149 m
Intercept Depth
92 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:92-93.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.06 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 28Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
28
Grade Unit
g/t
Intercept
1.5 m
True Width
1.5 m
From
93.5 m
To
95 m
Hole Depth
149 m
Intercept Depth
93.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:93.5-95
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.82
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 28 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 42.0 g/t·m is below.

Negative factors

  • 28 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“28”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.372Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.372
Grade Unit
g/t
Intercept
1.5 m
True Width
1.5 m
From
93.5 m
To
95 m
Hole Depth
149 m
Intercept Depth
93.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:93.5-95
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.82
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.372 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.372”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.97Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.97
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
93.5 m
To
95 m
Hole Depth
149 m
Intercept Depth
93.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:93.5-95
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.82
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.97 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 3.0 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.97 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.97”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.09Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.09
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
93.5 m
To
95 m
Hole Depth
149 m
Intercept Depth
93.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:93.5-95
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.82
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.09 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.1Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.1
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
93.5 m
To
95 m
Hole Depth
149 m
Intercept Depth
93.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:93.5-95
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.82
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 23Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
23
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
95 m
To
96 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:95-96
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.14
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 23 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 23.0 g/t·m is below.

Negative factors

  • 23 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“23”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.39Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.39
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
95 m
To
96 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:95-96
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.14
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.39”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 2.35Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.35
Grade Unit
%
Intercept
1 m
True Width
1 m
From
95 m
To
96 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:95-96
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.14
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2.35 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 2.4 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.35 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.35”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.14Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.14
Grade Unit
%
Intercept
1 m
True Width
1 m
From
95 m
To
96 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:95-96
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.14
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.14 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.14”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.09Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.09
Grade Unit
%
Intercept
1 m
True Width
1 m
From
95 m
To
96 m
Hole Depth
149 m
Intercept Depth
95 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:95-96
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.14
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.09 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.09”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 27Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
27
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
96 m
To
97 m
Hole Depth
149 m
Intercept Depth
96 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:96-97
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.98
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 27 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 27.0 g/t·m is below.

Negative factors

  • 27 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“27”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.472Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.472
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
96 m
To
97 m
Hole Depth
149 m
Intercept Depth
96 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:96-97
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.98
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.472 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.472”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 3.04Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
3.04
Grade Unit
%
Intercept
1 m
True Width
1 m
From
96 m
To
97 m
Hole Depth
149 m
Intercept Depth
96 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:96-97
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.98
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 3.04 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 3.0 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.04 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.04”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.14Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.14
Grade Unit
%
Intercept
1 m
True Width
1 m
From
96 m
To
97 m
Hole Depth
149 m
Intercept Depth
96 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:96-97
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.98
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.14 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.14”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.1Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.1
Grade Unit
%
Intercept
1 m
True Width
1 m
From
96 m
To
97 m
Hole Depth
149 m
Intercept Depth
96 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:96-97
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.98
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 32Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
32
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
97 m
To
98 m
Hole Depth
149 m
Intercept Depth
97 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:97-98
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 32 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 32.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“32”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.407Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.407
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
97 m
To
98 m
Hole Depth
149 m
Intercept Depth
97 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:97-98
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.407 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.407”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 3.47Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
3.47
Grade Unit
%
Intercept
1 m
True Width
1 m
From
97 m
To
98 m
Hole Depth
149 m
Intercept Depth
97 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:97-98
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 3.47 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 3.5 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.47 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.47”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.16Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.16
Grade Unit
%
Intercept
1 m
True Width
1 m
From
97 m
To
98 m
Hole Depth
149 m
Intercept Depth
97 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:97-98
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.16 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.16”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.11Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.11
Grade Unit
%
Intercept
1 m
True Width
1 m
From
97 m
To
98 m
Hole Depth
149 m
Intercept Depth
97 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:97-98
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.11 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 100Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
100
Grade Unit
g/t
Intercept
1.2 m
True Width
1.2 m
From
98 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
98 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:98-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.8
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 100 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 120.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“100”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.336Grade Unit: g/tIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.336
Grade Unit
g/t
Intercept
1.2 m
True Width
1.2 m
From
98 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
98 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:98-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.8
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.336 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.336”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 2.85Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.85
Grade Unit
%
Intercept
1.2 m
True Width
1.2 m
From
98 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
98 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:98-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.8
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2.85 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 3.4 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 2.85 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.85”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.15Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.15
Grade Unit
%
Intercept
1.2 m
True Width
1.2 m
From
98 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
98 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:98-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.8
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.15 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.24Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.24
Grade Unit
%
Intercept
1.2 m
True Width
1.2 m
From
98 m
To
99.2 m
Hole Depth
149 m
Intercept Depth
98 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:98-99.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.8
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.24 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.24”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.294Grade Unit: g/tIntercept: 0.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.294
Grade Unit
g/t
Intercept
0.5 m
True Width
0.5 m
From
102.9 m
To
103.4 m
Hole Depth
149 m
Intercept Depth
102.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:102.9-103.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.37
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.294 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.294 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.294”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 6Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
6
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
103.4 m
To
104.4 m
Hole Depth
149 m
Intercept Depth
103.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:103.4-104.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 6.0 g/t·m is below.

Negative factors

  • 6 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.042Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.042
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
103.4 m
To
104.4 m
Hole Depth
149 m
Intercept Depth
103.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:103.4-104.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.042 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.042 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.042”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.65Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.65
Grade Unit
%
Intercept
1 m
True Width
1 m
From
103.4 m
To
104.4 m
Hole Depth
149 m
Intercept Depth
103.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:103.4-104.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.65 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.7 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.65”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.02Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.02
Grade Unit
%
Intercept
1 m
True Width
1 m
From
103.4 m
To
104.4 m
Hole Depth
149 m
Intercept Depth
103.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:103.4-104.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.02 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.11Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.11
Grade Unit
%
Intercept
1 m
True Width
1 m
From
103.4 m
To
104.4 m
Hole Depth
149 m
Intercept Depth
103.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:103.4-104.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.81
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.11 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
104.4 m
To
105.4 m
Hole Depth
149 m
Intercept Depth
104.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:104.4-105.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.0 g/t·m is below.

Negative factors

  • 1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.017Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.017
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
104.4 m
To
105.4 m
Hole Depth
149 m
Intercept Depth
104.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:104.4-105.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.017 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.017 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.017”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.03Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.03
Grade Unit
%
Intercept
1 m
True Width
1 m
From
104.4 m
To
105.4 m
Hole Depth
149 m
Intercept Depth
104.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:104.4-105.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
104.4 m
To
105.4 m
Hole Depth
149 m
Intercept Depth
104.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:104.4-105.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.03Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.03
Grade Unit
%
Intercept
1 m
True Width
1 m
From
104.4 m
To
105.4 m
Hole Depth
149 m
Intercept Depth
104.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:104.4-105.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.07
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.01Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
105.4 m
To
106.4 m
Hole Depth
149 m
Intercept Depth
105.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:105.4-106.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
105.4 m
To
106.4 m
Hole Depth
149 m
Intercept Depth
105.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:105.4-106.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
105.4 m
To
106.4 m
Hole Depth
149 m
Intercept Depth
105.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:105.4-106.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.03Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.03
Grade Unit
%
Intercept
1 m
True Width
1 m
From
105.4 m
To
106.4 m
Hole Depth
149 m
Intercept Depth
105.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:105.4-106.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.011Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.011
Grade Unit
g/t
Intercept
1.1 m
True Width
1.1 m
From
106.4 m
To
107.5 m
Hole Depth
149 m
Intercept Depth
106.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:106.4-107.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.011 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.011 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.011”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.02Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.02
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
106.4 m
To
107.5 m
Hole Depth
149 m
Intercept Depth
106.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:106.4-107.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.02 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
106.4 m
To
107.5 m
Hole Depth
149 m
Intercept Depth
106.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:106.4-107.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.03Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.03
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
106.4 m
To
107.5 m
Hole Depth
149 m
Intercept Depth
106.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:106.4-107.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.05
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.005Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.005
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
107.5 m
To
108.5 m
Hole Depth
149 m
Intercept Depth
107.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:107.5-108.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.08
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.005 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.005 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.005”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.05Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.05
Grade Unit
%
Intercept
1 m
True Width
1 m
From
107.5 m
To
108.5 m
Hole Depth
149 m
Intercept Depth
107.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:107.5-108.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.08
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.05 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
107.5 m
To
108.5 m
Hole Depth
149 m
Intercept Depth
107.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:107.5-108.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.08
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.07Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.07
Grade Unit
%
Intercept
1 m
True Width
1 m
From
107.5 m
To
108.5 m
Hole Depth
149 m
Intercept Depth
107.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:107.5-108.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.08
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.005Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.005
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
108.5 m
To
109.5 m
Hole Depth
149 m
Intercept Depth
108.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:108.5-109.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.005 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.005 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.005”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
108.5 m
To
109.5 m
Hole Depth
149 m
Intercept Depth
108.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:108.5-109.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
108.5 m
To
109.5 m
Hole Depth
149 m
Intercept Depth
108.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:108.5-109.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.05Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.05
Grade Unit
%
Intercept
1 m
True Width
1 m
From
108.5 m
To
109.5 m
Hole Depth
149 m
Intercept Depth
108.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:108.5-109.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.05 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
109.5 m
To
110.5 m
Hole Depth
149 m
Intercept Depth
109.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:109.5-110.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.06
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.0 g/t·m is below.

Negative factors

  • 1 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.016Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.016
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
109.5 m
To
110.5 m
Hole Depth
149 m
Intercept Depth
109.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:109.5-110.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.06
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.016 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.016 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.016”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.02Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.02
Grade Unit
%
Intercept
1 m
True Width
1 m
From
109.5 m
To
110.5 m
Hole Depth
149 m
Intercept Depth
109.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:109.5-110.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.06
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.02 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1 m
True Width
1 m
From
109.5 m
To
110.5 m
Hole Depth
149 m
Intercept Depth
109.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:109.5-110.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.06
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.05Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.05
Grade Unit
%
Intercept
1 m
True Width
1 m
From
109.5 m
To
110.5 m
Hole Depth
149 m
Intercept Depth
109.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:109.5-110.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.06
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.05 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 51Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
51
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
110.5 m
To
111.5 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:110.5-111.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 51 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 51.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“51”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.534Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.534
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
110.5 m
To
111.5 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:110.5-111.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.534 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.534”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.58Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.58
Grade Unit
%
Intercept
1 m
True Width
1 m
From
110.5 m
To
111.5 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:110.5-111.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.58 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.6 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.58”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 1.39Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.39
Grade Unit
%
Intercept
1 m
True Width
1 m
From
110.5 m
To
111.5 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:110.5-111.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.39 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.4 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.39”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.11Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.11
Grade Unit
%
Intercept
1 m
True Width
1 m
From
110.5 m
To
111.5 m
Hole Depth
149 m
Intercept Depth
110.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:110.5-111.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.11
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.11 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 74Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
74
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
111.5 m
To
112.5 m
Hole Depth
149 m
Intercept Depth
111.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:111.5-112.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.64
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 74 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 74.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“74”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.525Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.525
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
111.5 m
To
112.5 m
Hole Depth
149 m
Intercept Depth
111.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:111.5-112.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.64
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.525 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.525”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.62Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.62
Grade Unit
%
Intercept
1 m
True Width
1 m
From
111.5 m
To
112.5 m
Hole Depth
149 m
Intercept Depth
111.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:111.5-112.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.64
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.62 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.6 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.62”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 1.94Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.94
Grade Unit
%
Intercept
1 m
True Width
1 m
From
111.5 m
To
112.5 m
Hole Depth
149 m
Intercept Depth
111.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:111.5-112.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.64
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.94 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.94”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.37Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.37
Grade Unit
%
Intercept
1 m
True Width
1 m
From
111.5 m
To
112.5 m
Hole Depth
149 m
Intercept Depth
111.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:111.5-112.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.64
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.37 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.37”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 45Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
45
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
112.5 m
To
113.5 m
Hole Depth
149 m
Intercept Depth
112.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:112.5-113.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 45 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 45.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“45”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.547Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.547
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
112.5 m
To
113.5 m
Hole Depth
149 m
Intercept Depth
112.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:112.5-113.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.547 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.547”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.17Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.17
Grade Unit
%
Intercept
1 m
True Width
1 m
From
112.5 m
To
113.5 m
Hole Depth
149 m
Intercept Depth
112.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:112.5-113.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.17 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.2 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.17”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.74Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.74
Grade Unit
%
Intercept
1 m
True Width
1 m
From
112.5 m
To
113.5 m
Hole Depth
149 m
Intercept Depth
112.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:112.5-113.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.74 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.7 %·m is below.

Negative factors

  • 0.74 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.74”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.07Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.07
Grade Unit
%
Intercept
1 m
True Width
1 m
From
112.5 m
To
113.5 m
Hole Depth
149 m
Intercept Depth
112.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:112.5-113.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 16Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
16
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
113.5 m
To
114.5 m
Hole Depth
149 m
Intercept Depth
113.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:113.5-114.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.78
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 16 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 16.0 g/t·m is below.

Negative factors

  • 16 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“16”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.15Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.15
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
113.5 m
To
114.5 m
Hole Depth
149 m
Intercept Depth
113.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:113.5-114.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.78
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.15 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.22Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.22
Grade Unit
%
Intercept
1 m
True Width
1 m
From
113.5 m
To
114.5 m
Hole Depth
149 m
Intercept Depth
113.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:113.5-114.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.78
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.22 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.22”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.29Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.29
Grade Unit
%
Intercept
1 m
True Width
1 m
From
113.5 m
To
114.5 m
Hole Depth
149 m
Intercept Depth
113.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:113.5-114.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.78
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.29 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.29”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.44Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.44
Grade Unit
%
Intercept
1 m
True Width
1 m
From
113.5 m
To
114.5 m
Hole Depth
149 m
Intercept Depth
113.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:113.5-114.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.78
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.44 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.44 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.44”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 117Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
117
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
114.5 m
To
115.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:114.5-115.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.88
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 117 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 117.0 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“117”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.534Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.534
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
114.5 m
To
115.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:114.5-115.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.88
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.534 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.534”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.93Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.93
Grade Unit
%
Intercept
1 m
True Width
1 m
From
114.5 m
To
115.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:114.5-115.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.88
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.93 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.9 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.93 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.93”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 4.51Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
4.51
Grade Unit
%
Intercept
1 m
True Width
1 m
From
114.5 m
To
115.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:114.5-115.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.88
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 4.51 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 4.5 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.51”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.11Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.11
Grade Unit
%
Intercept
1 m
True Width
1 m
From
114.5 m
To
115.5 m
Hole Depth
149 m
Intercept Depth
114.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:114.5-115.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.88
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.11 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.11”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 45Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
45
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
115.5 m
To
116.5 m
Hole Depth
149 m
Intercept Depth
115.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:115.5-116.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.22
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 45 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 45.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“45”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.71Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.71
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
115.5 m
To
116.5 m
Hole Depth
149 m
Intercept Depth
115.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:115.5-116.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.22
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.71 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.71”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.99Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.99
Grade Unit
%
Intercept
1 m
True Width
1 m
From
115.5 m
To
116.5 m
Hole Depth
149 m
Intercept Depth
115.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:115.5-116.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.22
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.99 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.0 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.99”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 1.9Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.9
Grade Unit
%
Intercept
1 m
True Width
1 m
From
115.5 m
To
116.5 m
Hole Depth
149 m
Intercept Depth
115.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:115.5-116.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.22
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.90”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 2Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2
Grade Unit
%
Intercept
1 m
True Width
1 m
From
115.5 m
To
116.5 m
Hole Depth
149 m
Intercept Depth
115.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:115.5-116.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.22
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 2.0 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.805Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.805
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
116.5 m
To
117.5 m
Hole Depth
149 m
Intercept Depth
116.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:116.5-117.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
5.68
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.805 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.805”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 86Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
86
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
117.5 m
To
118.5 m
Hole Depth
149 m
Intercept Depth
117.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:117.5-118.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.84
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 86 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 86.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“86”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.526Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.526
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
117.5 m
To
118.5 m
Hole Depth
149 m
Intercept Depth
117.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:117.5-118.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.84
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.526 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.526”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.85Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.85
Grade Unit
%
Intercept
1 m
True Width
1 m
From
117.5 m
To
118.5 m
Hole Depth
149 m
Intercept Depth
117.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:117.5-118.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.84
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.85 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.9 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.85 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.85”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 2.53Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.53
Grade Unit
%
Intercept
1 m
True Width
1 m
From
117.5 m
To
118.5 m
Hole Depth
149 m
Intercept Depth
117.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:117.5-118.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.84
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2.53 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 2.5 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.53”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 2.9Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.9
Grade Unit
%
Intercept
1 m
True Width
1 m
From
117.5 m
To
118.5 m
Hole Depth
149 m
Intercept Depth
117.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:117.5-118.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.84
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 2.9 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.90”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 28Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
28
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
118.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
118.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:118.5-119.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.9
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 28 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 28.0 g/t·m is below.

Negative factors

  • 28 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“28”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.285Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.285
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
118.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
118.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:118.5-119.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.9
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.285 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.285 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.285”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.65Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.65
Grade Unit
%
Intercept
1 m
True Width
1 m
From
118.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
118.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:118.5-119.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.9
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.65 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.6 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 1.65 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.65”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.44Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.44
Grade Unit
%
Intercept
1 m
True Width
1 m
From
118.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
118.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:118.5-119.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.9
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.44 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.44 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.44”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 1.68Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.68
Grade Unit
%
Intercept
1 m
True Width
1 m
From
118.5 m
To
119.5 m
Hole Depth
149 m
Intercept Depth
118.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:118.5-119.5
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.9
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.68 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.7 %·m is below.

Negative factors

  • 1.68 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.68”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 4Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
4
Grade Unit
g/t
Intercept
0.8 m
True Width
0.8 m
From
119.5 m
To
120.3 m
Hole Depth
149 m
Intercept Depth
119.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:119.5-120.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 3.2 g/t·m is below.

Negative factors

  • 4 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.099Grade Unit: g/tIntercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.099
Grade Unit
g/t
Intercept
0.8 m
True Width
0.8 m
From
119.5 m
To
120.3 m
Hole Depth
149 m
Intercept Depth
119.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:119.5-120.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.099 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.099 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.099”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 1.32Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
1.32
Grade Unit
%
Intercept
0.8 m
True Width
0.8 m
From
119.5 m
To
120.3 m
Hole Depth
149 m
Intercept Depth
119.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:119.5-120.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 1.32 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.1 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.32”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.04Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.04
Grade Unit
%
Intercept
0.8 m
True Width
0.8 m
From
119.5 m
To
120.3 m
Hole Depth
149 m
Intercept Depth
119.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:119.5-120.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.04 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.04”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.15Grade Unit: %Intercept: 0.8 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.15
Grade Unit
%
Intercept
0.8 m
True Width
0.8 m
From
119.5 m
To
120.3 m
Hole Depth
149 m
Intercept Depth
119.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:119.5-120.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1.53
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.15 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · silverGrade: 3Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
silver
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
3
Grade Unit
g/t
Intercept
0.9 m
True Width
0.9 m
From
120.3 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
120.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:120.3-121.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 2.7 g/t·m is below.

Negative factors

  • 3 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.057Grade Unit: g/tIntercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.057
Grade Unit
g/t
Intercept
0.9 m
True Width
0.9 m
From
120.3 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
120.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:120.3-121.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.057 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.057 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.057”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 2.05Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
2.05
Grade Unit
%
Intercept
0.9 m
True Width
0.9 m
From
120.3 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
120.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:120.3-121.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 2.05 % copper is strong against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.8 %·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 2.05 % copper is strong on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.05”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.07Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.9 m
True Width
0.9 m
From
120.3 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
120.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:120.3-121.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.96Grade Unit: %Intercept: 0.9 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.96
Grade Unit
%
Intercept
0.9 m
True Width
0.9 m
From
120.3 m
To
121.2 m
Hole Depth
149 m
Intercept Depth
120.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:120.3-121.2
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
2.43
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.96 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.9 %·m is below.

Negative factors

  • 0.96 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.96”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.009Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.009
Grade Unit
g/t
Intercept
1.1 m
True Width
1.1 m
From
121.2 m
To
122.3 m
Hole Depth
149 m
Intercept Depth
121.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:121.2-122.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.009 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.009 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.009”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.01Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
121.2 m
To
122.3 m
Hole Depth
149 m
Intercept Depth
121.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:121.2-122.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0.01Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
121.2 m
To
122.3 m
Hole Depth
149 m
Intercept Depth
121.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:121.2-122.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.03Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.03
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
121.2 m
To
122.3 m
Hole Depth
149 m
Intercept Depth
121.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:121.2-122.3
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.04
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.009Grade Unit: g/tIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.009
Grade Unit
g/t
Intercept
1.1 m
True Width
1.1 m
From
122.3 m
To
123.4 m
Hole Depth
149 m
Intercept Depth
122.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:122.3-123.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.009 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.009 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.009”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
122.3 m
To
123.4 m
Hole Depth
149 m
Intercept Depth
122.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:122.3-123.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
122.3 m
To
123.4 m
Hole Depth
149 m
Intercept Depth
122.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:122.3-123.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.03Grade Unit: %Intercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.03
Grade Unit
%
Intercept
1.1 m
True Width
1.1 m
From
122.3 m
To
123.4 m
Hole Depth
149 m
Intercept Depth
122.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:122.3-123.4
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.03
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.03 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1.2 m
True Width
1.2 m
From
123.4 m
To
124.6 m
Hole Depth
149 m
Intercept Depth
123.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:123.4-124.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.02
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1.2 m
True Width
1.2 m
From
123.4 m
To
124.6 m
Hole Depth
149 m
Intercept Depth
123.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:123.4-124.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.02
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.02Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.02
Grade Unit
%
Intercept
1.2 m
True Width
1.2 m
From
123.4 m
To
124.6 m
Hole Depth
149 m
Intercept Depth
123.4 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:123.4-124.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.02
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.02 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.02”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.081Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.081
Grade Unit
g/t
Intercept
1 m
True Width
1 m
From
124.6 m
To
125.6 m
Hole Depth
149 m
Intercept Depth
124.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:124.6-125.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.081 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.081 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.081”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.07Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.07
Grade Unit
%
Intercept
1 m
True Width
1 m
From
124.6 m
To
125.6 m
Hole Depth
149 m
Intercept Depth
124.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:124.6-125.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1 m
True Width
1 m
From
124.6 m
To
125.6 m
Hole Depth
149 m
Intercept Depth
124.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:124.6-125.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.07Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.07
Grade Unit
%
Intercept
1 m
True Width
1 m
From
124.6 m
To
125.6 m
Hole Depth
149 m
Intercept Depth
124.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:124.6-125.6
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.18
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.07 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.07”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · goldGrade: 0.009Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
gold
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.009
Grade Unit
g/t
Intercept
1.5 m
True Width
1.5 m
From
125.6 m
To
127.1 m
Hole Depth
149 m
Intercept Depth
125.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:125.6-127.1
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.009 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.009 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.009”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · copperGrade: 0.27Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
copper
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.27
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
125.6 m
To
127.1 m
Hole Depth
149 m
Intercept Depth
125.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:125.6-127.1
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.27 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · leadGrade: 0Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
lead
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
125.6 m
To
127.1 m
Hole Depth
149 m
Intercept Depth
125.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:125.6-127.1
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical Minerals · zincGrade: 0.15Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Commodity
zinc
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Grade
0.15
Grade Unit
%
Intercept
1.5 m
True Width
1.5 m
From
125.6 m
To
127.1 m
Hole Depth
149 m
Intercept Depth
125.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
WD-26-11:125.6-127.1
Mining Method
unknown

Location

Location
Upper Zone Above Void
Azimuth
355 °
Dip
-50 °
Loc. Source
document

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
0.32
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.15 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.15”

Context: TABLE 2: DDH WD-26-11 CERTIFIED ASSAYS -

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical MineralsIntercept: 10.7 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Intercept
10.7 m
True Width
10.7 m
Hole Depth
149 m

Classification

Deposit Type
vms
Sample Type
drill

Location

Azimuth
355 °
Dip
-50 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.08
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This silver grade is part of a high-grade polymetallic VMS intercept, contributing to the overall value of the zone. The disclosure of true width adds confidence.

Positive factors

  • High silver grade for the interval
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · text

“3.08% CU-EQ Over 10.70M”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical MineralsIntercept: 9.3 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Intercept
9.3 m
True Width
9.3 m
Hole Depth
149 m

Classification

Deposit Type
vms
Sample Type
drill

Location

Azimuth
355 °
Dip
-50 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.27
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This silver grade is part of a high-grade polymetallic VMS intercept, contributing to the overall value of the zone. The disclosure of true width adds confidence.

Positive factors

  • High silver grade for the interval
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · text

“3.27% CU-EQ Over 9.30M”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

WD-26-11Wedge Critical MineralsIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
WD-26-11
Project
Wedge Critical Minerals
Region
canada_nb
Reported Region
canada_nb
Ticker
NINE

Geometry

Intercept
5 m
True Width
5 m
Hole Depth
149 m

Classification

Deposit Type
vms
Sample Type
drill

Location

Azimuth
355 °
Dip
-50 °

QA/QC

Laboratory
ALS Global
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.3
Metal Eq. Unit
% Cu-Eq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-21T00:00:00.000Z

Reasoning: This silver grade is part of a high-grade polymetallic VMS intercept, contributing to the overall value of the zone. The disclosure of true width adds confidence.

Positive factors

  • High silver grade for the interval
  • True width disclosed
  • Part of a significant polymetallic intercept

Evidence · text

“4.30% CU-EQ Over 5.0M”

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.