NioBay Metals Announces Additional Mineralized Intersections

Original announcement by tmx on

Company
NioBay Metals Inc.
Ticker
NBY
Exchange
TSX
Region
Quebec
Primary commodity
Niobium
Secondary commodities
Tantalum, Rare earth elements, Strontium
Document categories
Drill results, Metallurgy
Extracted
2026-09-12 15:20:26 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

NioBay Metals Inc. announced additional mineralized intersections from its 2025 summer drill campaign at the Crevier niobium and tantalum project in Quebec. The 15-hole campaign confirmed mineralization continuity over a strike length exceeding 6 km, with results to be used for a resource estimate update. The company also completed bulk sampling and plans a larger pilot test for niobium oxide production for battery manufacturers.

Reasoning: The drill results confirm significant mineralization continuity at the Crevier project, which is a positive step towards updating the resource estimate. The completion of bulk sampling and plans for a larger pilot test also indicate good progress on the metallurgical front, particularly for niobium oxide production for battery manufacturers. The grades are consistent with typical niobium deposits, and the inclusion of tantalum, rare earth elements, and strontium adds potential value.

Positive factors

  • Mineralization continuity confirmed over 6 km strike length
  • Results will be used to update a resource estimate
  • Bulk sampling completed for further metallurgical testing
  • Larger pilot test (140 tonnes) planned, indicating project advancement
  • QP/CP signed off on the results

Negative factors

  • No true width disclosed for intercepts
  • No specific QA/QC methods or laboratory disclosed

Facts used in scoring: 123

Extracted facts

Stored fact records: 123. Some facts used in scoring do not have a stored record.

Drill Results (123)

1532-25-01Crevier · niobiumGrade: 0.2273Grade Unit: %Intercept: 9.9 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2273
Grade Unit
%
Intercept
9.9 m
From
116.1 m
To
126 m
Hole Depth
150 m
Intercept Depth
116.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:116.1-126

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept confirms mineralization in hole 1532-25-01 with a good length and grade, contributing to the overall continuity of the deposit.

Positive factors

  • Good intercept length
  • Grade is within expected range for niobium deposits

Negative factors

  • No true width disclosed

Evidence · table

“0.2273”

Context: 9.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · niobiumGrade: 0.2991Grade Unit: %Intercept: 4 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2991
Grade Unit
%
Intercept
4 m
From
128.5 m
To
132.5 m
Hole Depth
150 m
Intercept Depth
116.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:128.5-132.5

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a higher niobium grade over a shorter interval, adding to the confirmed mineralization in this hole.

Positive factors

  • Higher grade intercept
  • Contributes to overall mineralization continuity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.2991”

Context: 4.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · niobiumGrade: 0.3281Grade Unit: %Intercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.3281
Grade Unit
%
Intercept
4.05 m
From
214 m
To
218.05 m
Hole Depth
264 m
Intercept Depth
214 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:214-218.05

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a good niobium grade over a moderate length, confirming mineralization in hole 1532-25-02.

Positive factors

  • Higher grade intercept
  • Confirms mineralization at depth

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.3281”

Context: 4.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · niobiumGrade: 0.192Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.192
Grade Unit
%
Intercept
4.2 m
From
221.9 m
To
226.1 m
Hole Depth
264 m
Intercept Depth
214 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:221.9-226.1

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a short interval, extending the known mineralization in hole 1532-25-02.

Positive factors

  • Contributes to overall mineralization continuity

Negative factors

  • Lower grade compared to other intercepts
  • No true width disclosed

Evidence · table

“0.1920”

Context: 4.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · niobiumGrade: 0.2014Grade Unit: %Intercept: 6.15 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2014
Grade Unit
%
Intercept
6.15 m
From
227 m
To
233.15 m
Hole Depth
264 m
Intercept Depth
214 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:227-233.15

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a good length, further confirming mineralization in hole 1532-25-02.

Positive factors

  • Good intercept length
  • Confirms mineralization at depth

Negative factors

  • No true width disclosed

Evidence · table

“0.2014”

Context: 6.15

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · niobiumGrade: 0.1804Grade Unit: %Intercept: 3.25 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1804
Grade Unit
%
Intercept
3.25 m
From
247.9 m
To
251.15 m
Hole Depth
264 m
Intercept Depth
214 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:247.9-251.15

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a short interval, extending the known mineralization in hole 1532-25-02.

Positive factors

  • Extends mineralization at depth

Negative factors

  • Lower grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.1804”

Context: 3.25

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-03Crevier · niobiumGrade: 0.2307Grade Unit: %Intercept: 7.55 mView all details
Link to this fact

Identity

Hole ID
1532-25-03
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2307
Grade Unit
%
Intercept
7.55 m
From
107.45 m
To
115 m
Hole Depth
159 m
Intercept Depth
107.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-03:107.45-115

Location

Easting
663220.32
Northing
5479755.95
Elevation
336.9 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept confirms mineralization in hole 1532-25-03 with a good length and grade, contributing to the overall continuity of the deposit.

Positive factors

  • Good intercept length
  • Grade is within expected range for niobium deposits

Negative factors

  • No true width disclosed

Evidence · table

“0.2307”

Context: 7.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-03Crevier · niobiumGrade: 0.2546Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-03
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2546
Grade Unit
%
Intercept
1 m
From
117.25 m
To
118.25 m
Hole Depth
159 m
Intercept Depth
107.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-03:117.25-118.25

Location

Easting
663220.32
Northing
5479755.95
Elevation
336.9 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a very short interval, contributing to the overall mineralization continuity.

Positive factors

  • Grade is within expected range for niobium deposits

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.2546”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · niobiumGrade: 0.2003Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2003
Grade Unit
%
Intercept
1.05 m
From
99.1 m
To
100.15 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:99.1-100.15

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a very short interval, contributing to the overall mineralization continuity.

Positive factors

  • Grade is within expected range for niobium deposits

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.2003”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · niobiumGrade: 0.2633Grade Unit: %Intercept: 3.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2633
Grade Unit
%
Intercept
3.1 m
From
166.85 m
To
169.95 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:166.85-169.95

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a good niobium grade over a short interval, contributing to the overall mineralization continuity.

Positive factors

  • Good grade for niobium

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.2633”

Context: 3.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · niobiumGrade: 0.3541Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.3541
Grade Unit
%
Intercept
1 m
From
176.2 m
To
177.2 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:176.2-177.2

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a high niobium grade over a very short interval, indicating a high-grade zone within the mineralization.

Positive factors

  • High grade for niobium

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.3541”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · niobiumGrade: 0.2473Grade Unit: %Intercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2473
Grade Unit
%
Intercept
11.3 m
From
189.5 m
To
200.8 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:189.5-200.8

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a good niobium grade over a significant length, contributing positively to the overall mineralization continuity.

Positive factors

  • Good intercept length
  • Good grade for niobium

Negative factors

  • No true width disclosed

Evidence · table

“0.2473”

Context: 11.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · niobiumGrade: 0.1838Grade Unit: %Intercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1838
Grade Unit
%
Intercept
4.05 m
From
221.6 m
To
225.65 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:221.6-225.65

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a short interval, extending the known mineralization in hole 1532-25-04.

Positive factors

  • Extends mineralization at depth

Negative factors

  • Lower grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.1838”

Context: 4.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · niobiumGrade: 0.1774Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1774
Grade Unit
%
Intercept
1 m
From
230 m
To
231 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:230-231

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a low niobium grade over a very short interval, extending the known mineralization in hole 1532-25-04.

Positive factors

  • Extends mineralization at depth

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.1774”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-05Crevier · niobiumGrade: 0.2558Grade Unit: %Intercept: 8.7 mView all details
Link to this fact

Identity

Hole ID
1532-25-05
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2558
Grade Unit
%
Intercept
8.7 m
From
115.3 m
To
124 m
Hole Depth
174 m
Intercept Depth
115.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-05:115.3-124

Location

Easting
663281.86
Northing
5479706.21
Elevation
336.96 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept confirms mineralization in hole 1532-25-05 with a good length and grade, contributing to the overall continuity of the deposit.

Positive factors

  • Good intercept length
  • Good grade for niobium

Negative factors

  • No true width disclosed

Evidence · table

“0.2558”

Context: 8.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-05Crevier · niobiumGrade: 0.179Grade Unit: %Intercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1532-25-05
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.179
Grade Unit
%
Intercept
2.8 m
From
129.7 m
To
132.5 m
Hole Depth
174 m
Intercept Depth
115.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-05:129.7-132.5

Location

Easting
663281.86
Northing
5479706.21
Elevation
336.96 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a low niobium grade over a short interval, extending the known mineralization in hole 1532-25-05.

Positive factors

  • Extends mineralization at depth

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.1790”

Context: 2.80

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · niobiumGrade: 0.216Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.216
Grade Unit
%
Intercept
1.05 m
From
88.65 m
To
89.7 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:88.65-89.7

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a very short interval, contributing to the overall mineralization continuity.

Positive factors

  • Grade is within expected range for niobium deposits

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.2160”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · niobiumGrade: 0.2173Grade Unit: %Intercept: 3.8 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2173
Grade Unit
%
Intercept
3.8 m
From
197.85 m
To
201.65 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:197.85-201.65

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a short interval, contributing to the overall mineralization continuity.

Positive factors

  • Grade is within expected range for niobium deposits

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.2173”

Context: 3.80

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · niobiumGrade: 0.1951Grade Unit: %Intercept: 4.45 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1951
Grade Unit
%
Intercept
4.45 m
From
203.6 m
To
208.05 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:203.6-208.05

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a short interval, extending the known mineralization in hole 1532-25-06.

Positive factors

  • Contributes to overall mineralization continuity

Negative factors

  • Lower grade compared to other intercepts
  • No true width disclosed

Evidence · table

“0.1951”

Context: 4.45

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · niobiumGrade: 0.2461Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2461
Grade Unit
%
Intercept
2 m
From
237.4 m
To
239.4 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:237.4-239.4

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a good niobium grade over a short interval, contributing to the overall mineralization continuity.

Positive factors

  • Good grade for niobium

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.2461”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · niobiumGrade: 0.1874Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1874
Grade Unit
%
Intercept
1.2 m
From
252.8 m
To
254 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:252.8-254

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a very short interval, extending the known mineralization in hole 1532-25-06.

Positive factors

  • Extends mineralization at depth

Negative factors

  • Lower grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.1874”

Context: 1.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · niobiumGrade: 0.1717Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1717
Grade Unit
%
Intercept
1.05 m
From
63.45 m
To
64.5 m
Hole Depth
156 m
Intercept Depth
63.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:63.45-64.5

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a low niobium grade over a very short interval, confirming mineralization at shallow depth in hole 1532-25-07.

Positive factors

  • Confirms mineralization at shallow depth

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.1717”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · niobiumGrade: 0.3276Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.3276
Grade Unit
%
Intercept
1 m
From
71.5 m
To
72.5 m
Hole Depth
156 m
Intercept Depth
63.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:71.5-72.5

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a high niobium grade over a very short interval, indicating a high-grade zone within the mineralization.

Positive factors

  • High grade for niobium

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.3276”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · niobiumGrade: 0.194Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.194
Grade Unit
%
Intercept
5 m
From
108 m
To
113 m
Hole Depth
156 m
Intercept Depth
63.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:108-113

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a good length, confirming mineralization at depth in hole 1532-25-07.

Positive factors

  • Good intercept length
  • Confirms mineralization at depth

Negative factors

  • Lower grade compared to other intercepts
  • No true width disclosed

Evidence · table

“0.1940”

Context: 5.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · niobiumGrade: 0.1931Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1931
Grade Unit
%
Intercept
1 m
From
297 m
To
298 m
Hole Depth
372 m
Intercept Depth
297 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:297-298

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a very short interval, confirming mineralization at depth in hole 1532-25-09.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Lower grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.1931”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · niobiumGrade: 0.1987Grade Unit: %Intercept: 2.45 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1987
Grade Unit
%
Intercept
2.45 m
From
53.6 m
To
56.05 m
Hole Depth
153 m
Intercept Depth
53.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:53.6-56.05

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a short interval, confirming mineralization at shallow depth in hole 1532-25-11.

Positive factors

  • Confirms mineralization at shallow depth

Negative factors

  • Lower grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“0.1987”

Context: 2.45

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · niobiumGrade: 0.2975Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2975
Grade Unit
%
Intercept
1.05 m
From
66.2 m
To
67.25 m
Hole Depth
153 m
Intercept Depth
53.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:66.2-67.25

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a high niobium grade over a very short interval, indicating a high-grade zone within the mineralization.

Positive factors

  • Higher grade for niobium

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.2975”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · niobiumGrade: 0.2249Grade Unit: %Intercept: 6.9 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2249
Grade Unit
%
Intercept
6.9 m
From
69.1 m
To
76 m
Hole Depth
153 m
Intercept Depth
53.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:69.1-76

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept confirms mineralization in hole 1532-25-11 with a good length and grade, contributing to the overall continuity of the deposit.

Positive factors

  • Good intercept length
  • Grade is within expected range for niobium deposits

Negative factors

  • No true width disclosed

Evidence · table

“0.2249”

Context: 6.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · niobiumGrade: 0.2228Grade Unit: %Intercept: 1.65 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.2228
Grade Unit
%
Intercept
1.65 m
From
96.35 m
To
98 m
Hole Depth
153 m
Intercept Depth
53.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:96.35-98

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a moderate niobium grade over a very short interval, contributing to the overall mineralization continuity.

Positive factors

  • Grade is within expected range for niobium deposits

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.2228”

Context: 1.65

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · niobiumGrade: 0.1731Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
niobium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
0.1731
Grade Unit
%
Intercept
1.05 m
From
105.05 m
To
106.1 m
Hole Depth
153 m
Intercept Depth
53.6 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:105.05-106.1

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a low niobium grade over a very short interval, extending the known mineralization in hole 1532-25-11.

Positive factors

  • Extends mineralization at depth

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“0.1731”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · tantalumGrade: 159Grade Unit: ppmIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
159
Grade Unit
ppm
Intercept
1.5 m
From
112 m
To
113.5 m
Hole Depth
150 m
Intercept Depth
112 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:112-113.5

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“159”

Context: 1.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · tantalumGrade: 223Grade Unit: ppmIntercept: 10.9 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
223
Grade Unit
ppm
Intercept
10.9 m
From
116.1 m
To
127 m
Hole Depth
150 m
Intercept Depth
112 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:116.1-127

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“223”

Context: 10.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · tantalumGrade: 314Grade Unit: ppmIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
314
Grade Unit
ppm
Intercept
4 m
From
128.5 m
To
132.5 m
Hole Depth
150 m
Intercept Depth
112 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:128.5-132.5

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a higher tantalum grade over a shorter interval, indicating a high-grade tantalum zone.

Positive factors

  • Higher grade tantalum intercept
  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“314”

Context: 4.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · tantalumGrade: 330Grade Unit: ppmIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
330
Grade Unit
ppm
Intercept
1.3 m
From
198.7 m
To
200 m
Hole Depth
264 m
Intercept Depth
198.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:198.7-200

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a high tantalum grade over a very short interval, indicating a high-grade tantalum zone.

Positive factors

  • Higher grade tantalum intercept
  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“330”

Context: 1.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · tantalumGrade: 247Grade Unit: ppmIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
247
Grade Unit
ppm
Intercept
7 m
From
213 m
To
220 m
Hole Depth
264 m
Intercept Depth
198.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:213-220

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“247”

Context: 7.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · tantalumGrade: 192Grade Unit: ppmIntercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
192
Grade Unit
ppm
Intercept
4.2 m
From
221.9 m
To
226.1 m
Hole Depth
264 m
Intercept Depth
198.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:221.9-226.1

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“192”

Context: 4.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · tantalumGrade: 226Grade Unit: ppmIntercept: 6.15 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
226
Grade Unit
ppm
Intercept
6.15 m
From
227 m
To
233.15 m
Hole Depth
264 m
Intercept Depth
198.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:227-233.15

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“226”

Context: 6.15

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-02Crevier · tantalumGrade: 144Grade Unit: ppmIntercept: 3.25 mView all details
Link to this fact

Identity

Hole ID
1532-25-02
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
144
Grade Unit
ppm
Intercept
3.25 m
From
247.9 m
To
251.15 m
Hole Depth
264 m
Intercept Depth
198.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-02:247.9-251.15

Location

Easting
663171.51
Northing
5479817.8
Elevation
338.71 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“144”

Context: 3.25

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-03Crevier · tantalumGrade: 231Grade Unit: ppmIntercept: 7.55 mView all details
Link to this fact

Identity

Hole ID
1532-25-03
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
231
Grade Unit
ppm
Intercept
7.55 m
From
107.45 m
To
115 m
Hole Depth
159 m
Intercept Depth
107.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-03:107.45-115

Location

Easting
663220.32
Northing
5479755.95
Elevation
336.9 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“231”

Context: 7.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-03Crevier · tantalumGrade: 206Grade Unit: ppmIntercept: 1.75 mView all details
Link to this fact

Identity

Hole ID
1532-25-03
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
206
Grade Unit
ppm
Intercept
1.75 m
From
117.25 m
To
119 m
Hole Depth
159 m
Intercept Depth
107.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-03:117.25-119

Location

Easting
663220.32
Northing
5479755.95
Elevation
336.9 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“206”

Context: 1.75

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 225Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
225
Grade Unit
ppm
Intercept
1.05 m
From
99.1 m
To
100.15 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:99.1-100.15

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“225”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 223Grade Unit: ppmIntercept: 3.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
223
Grade Unit
ppm
Intercept
3.1 m
From
166.85 m
To
169.95 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:166.85-169.95

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“223”

Context: 3.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 426Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
426
Grade Unit
ppm
Intercept
1 m
From
176.2 m
To
177.2 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:176.2-177.2

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a high tantalum grade over a very short interval, indicating a high-grade tantalum zone.

Positive factors

  • High grade tantalum intercept
  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“426”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 250Grade Unit: ppmIntercept: 15.7 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
250
Grade Unit
ppm
Intercept
15.7 m
From
186.3 m
To
202 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:186.3-202

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing positively to the polymetallic nature of the deposit.

Positive factors

  • Significant intercept length
  • Good grade for tantalum
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“250”

Context: 15.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 170Grade Unit: ppmIntercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
170
Grade Unit
ppm
Intercept
4.05 m
From
221.6 m
To
225.65 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:221.6-225.65

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“170”

Context: 4.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 175Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
175
Grade Unit
ppm
Intercept
2 m
From
229 m
To
231 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:229-231

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“175”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-04Crevier · tantalumGrade: 102Grade Unit: ppmIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
1532-25-04
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
102
Grade Unit
ppm
Intercept
1.55 m
From
271.45 m
To
273 m
Hole Depth
300 m
Intercept Depth
99.1 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-04:271.45-273

Location

Easting
663221.1
Northing
5479756.16
Elevation
329.75 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“102”

Context: 1.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-05Crevier · tantalumGrade: 272Grade Unit: ppmIntercept: 8.7 mView all details
Link to this fact

Identity

Hole ID
1532-25-05
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
272
Grade Unit
ppm
Intercept
8.7 m
From
115.3 m
To
124 m
Hole Depth
174 m
Intercept Depth
115.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-05:115.3-124

Location

Easting
663281.86
Northing
5479706.21
Elevation
336.96 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Good grade for tantalum
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“272”

Context: 8.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-05Crevier · tantalumGrade: 150Grade Unit: ppmIntercept: 2.8 mView all details
Link to this fact

Identity

Hole ID
1532-25-05
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
150
Grade Unit
ppm
Intercept
2.8 m
From
129.7 m
To
132.5 m
Hole Depth
174 m
Intercept Depth
115.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-05:129.7-132.5

Location

Easting
663281.86
Northing
5479706.21
Elevation
336.96 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“150”

Context: 2.80

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-05Crevier · tantalumGrade: 218Grade Unit: ppmIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-05
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
218
Grade Unit
ppm
Intercept
1.1 m
From
135.1 m
To
136.2 m
Hole Depth
174 m
Intercept Depth
115.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-05:135.1-136.2

Location

Easting
663281.86
Northing
5479706.21
Elevation
336.96 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“218”

Context: 1.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · tantalumGrade: 222Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
222
Grade Unit
ppm
Intercept
1.05 m
From
88.65 m
To
89.7 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:88.65-89.7

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“222”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · tantalumGrade: 131Grade Unit: ppmIntercept: 2.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
131
Grade Unit
ppm
Intercept
2.1 m
From
104.9 m
To
107 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:104.9-107

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“131”

Context: 2.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · tantalumGrade: 151Grade Unit: ppmIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
151
Grade Unit
ppm
Intercept
2.2 m
From
189.3 m
To
191.5 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:189.3-191.5

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“151”

Context: 2.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · tantalumGrade: 213Grade Unit: ppmIntercept: 10.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
213
Grade Unit
ppm
Intercept
10.2 m
From
197.85 m
To
208.05 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:197.85-208.05

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“213”

Context: 10.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · tantalumGrade: 128Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
128
Grade Unit
ppm
Intercept
2 m
From
237.4 m
To
239.4 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:237.4-239.4

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“128”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-06Crevier · tantalumGrade: 164Grade Unit: ppmIntercept: 2.4 mView all details
Link to this fact

Identity

Hole ID
1532-25-06
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
164
Grade Unit
ppm
Intercept
2.4 m
From
252.8 m
To
255.2 m
Hole Depth
261 m
Intercept Depth
88.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-06:252.8-255.2

Location

Easting
663282.23
Northing
5479706.43
Elevation
336.96 m
Azimuth
230 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“164”

Context: 2.40

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · tantalumGrade: 229Grade Unit: ppmIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
229
Grade Unit
ppm
Intercept
1.9 m
From
8.45 m
To
10.35 m
Hole Depth
156 m
Intercept Depth
8.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:8.45-10.35

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“229”

Context: 1.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · tantalumGrade: 119Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
119
Grade Unit
ppm
Intercept
1.05 m
From
63.45 m
To
64.5 m
Hole Depth
156 m
Intercept Depth
8.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:63.45-64.5

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“119”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · tantalumGrade: 159Grade Unit: ppmIntercept: 3.5 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
159
Grade Unit
ppm
Intercept
3.5 m
From
71.5 m
To
75 m
Hole Depth
156 m
Intercept Depth
8.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:71.5-75

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“159”

Context: 3.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · tantalumGrade: 113Grade Unit: ppmIntercept: 2.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
113
Grade Unit
ppm
Intercept
2.3 m
From
88.85 m
To
91.15 m
Hole Depth
156 m
Intercept Depth
8.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:88.85-91.15

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“113”

Context: 2.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · tantalumGrade: 118Grade Unit: ppmIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
118
Grade Unit
ppm
Intercept
2.95 m
From
95.2 m
To
98.15 m
Hole Depth
156 m
Intercept Depth
8.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:95.2-98.15

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“118”

Context: 2.95

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-07Crevier · tantalumGrade: 185Grade Unit: ppmIntercept: 8 mView all details
Link to this fact

Identity

Hole ID
1532-25-07
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
185
Grade Unit
ppm
Intercept
8 m
From
107.15 m
To
115.15 m
Hole Depth
156 m
Intercept Depth
8.45 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-07:107.15-115.15

Location

Easting
663353.7
Northing
5479611.03
Elevation
329.39 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“185”

Context: 8.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · tantalumGrade: 106Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
106
Grade Unit
ppm
Intercept
1 m
From
317.5 m
To
318.5 m
Hole Depth
381 m
Intercept Depth
317.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:317.5-318.5

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“106”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · tantalumGrade: 124Grade Unit: ppmIntercept: 1.6 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
124
Grade Unit
ppm
Intercept
1.6 m
From
322.4 m
To
324 m
Hole Depth
381 m
Intercept Depth
317.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:322.4-324

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“124”

Context: 1.60

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · tantalumGrade: 185Grade Unit: ppmIntercept: 10.5 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
185
Grade Unit
ppm
Intercept
10.5 m
From
333.5 m
To
344 m
Hole Depth
381 m
Intercept Depth
317.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:333.5-344

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“185”

Context: 10.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · tantalumGrade: 123Grade Unit: ppmIntercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
123
Grade Unit
ppm
Intercept
4.05 m
From
346 m
To
350.05 m
Hole Depth
381 m
Intercept Depth
317.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:346-350.05

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“123”

Context: 4.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · tantalumGrade: 143Grade Unit: ppmIntercept: 5.8 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
143
Grade Unit
ppm
Intercept
5.8 m
From
352 m
To
357.8 m
Hole Depth
381 m
Intercept Depth
317.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:352-357.8

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“143”

Context: 5.80

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · tantalumGrade: 190Grade Unit: ppmIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
190
Grade Unit
ppm
Intercept
2.95 m
From
362 m
To
364.95 m
Hole Depth
381 m
Intercept Depth
317.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:362-364.95

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“190”

Context: 2.95

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · tantalumGrade: 123Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
123
Grade Unit
ppm
Intercept
1.05 m
From
183.4 m
To
184.45 m
Hole Depth
372 m
Intercept Depth
183.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:183.4-184.45

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“123”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · tantalumGrade: 112Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
112
Grade Unit
ppm
Intercept
1.2 m
From
222.55 m
To
223.75 m
Hole Depth
372 m
Intercept Depth
183.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:222.55-223.75

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“112”

Context: 1.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · tantalumGrade: 145Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
145
Grade Unit
ppm
Intercept
1 m
From
278 m
To
279 m
Hole Depth
372 m
Intercept Depth
183.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:278-279

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“145”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · tantalumGrade: 198Grade Unit: ppmIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
198
Grade Unit
ppm
Intercept
16 m
From
282 m
To
298 m
Hole Depth
372 m
Intercept Depth
183.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:282-298

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Significant intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“198”

Context: 16.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · tantalumGrade: 148Grade Unit: ppmIntercept: 4.8 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
148
Grade Unit
ppm
Intercept
4.8 m
From
301 m
To
305.8 m
Hole Depth
372 m
Intercept Depth
183.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:301-305.8

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“148”

Context: 4.80

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · tantalumGrade: 189Grade Unit: ppmIntercept: 19.85 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
189
Grade Unit
ppm
Intercept
19.85 m
From
231.15 m
To
251 m
Hole Depth
354 m
Intercept Depth
231.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:231.15-251

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Significant intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“189”

Context: 19.85

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · tantalumGrade: 189Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
189
Grade Unit
ppm
Intercept
2 m
From
256.5 m
To
258.5 m
Hole Depth
354 m
Intercept Depth
231.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:256.5-258.5

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“189”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-12Crevier · tantalumGrade: 101Grade Unit: ppmIntercept: 2.15 mView all details
Link to this fact

Identity

Hole ID
1532-25-12
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
101
Grade Unit
ppm
Intercept
2.15 m
From
7.15 m
To
9.3 m
Hole Depth
150 m
Intercept Depth
7.15 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-12:7.15-9.3

Location

Easting
663499.51
Northing
5479459.54
Elevation
322.42 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“101”

Context: 2.15

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · tantalumGrade: 134Grade Unit: ppmIntercept: 4.5 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
134
Grade Unit
ppm
Intercept
4.5 m
From
8.8 m
To
13.3 m
Hole Depth
153 m
Intercept Depth
8.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:8.8-13.3

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“134”

Context: 4.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · tantalumGrade: 107Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
107
Grade Unit
ppm
Intercept
1.2 m
From
53.6 m
To
54.8 m
Hole Depth
153 m
Intercept Depth
8.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:53.6-54.8

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Very short intercept length
  • No true width disclosed

Evidence · table

“107”

Context: 1.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · tantalumGrade: 230Grade Unit: ppmIntercept: 9.8 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
230
Grade Unit
ppm
Intercept
9.8 m
From
66.2 m
To
76 m
Hole Depth
153 m
Intercept Depth
8.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:66.2-76

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows good tantalum mineralization over a significant length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“230”

Context: 9.80

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · tantalumGrade: 178Grade Unit: ppmIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
178
Grade Unit
ppm
Intercept
6.1 m
From
95.7 m
To
101.8 m
Hole Depth
153 m
Intercept Depth
8.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:95.7-101.8

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization over a good length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of tantalum as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“178”

Context: 6.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-11Crevier · tantalumGrade: 303Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-11
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
303
Grade Unit
ppm
Intercept
1.05 m
From
105.05 m
To
106.1 m
Hole Depth
153 m
Intercept Depth
8.8 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-11:105.05-106.1

Location

Easting
663424.41
Northing
5479547.45
Elevation
324.97 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows a high tantalum grade over a very short interval, indicating a high-grade tantalum zone.

Positive factors

  • High grade tantalum intercept
  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“303”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-15Crevier · tantalumGrade: 104Grade Unit: ppmIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-15
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
104
Grade Unit
ppm
Intercept
1.3 m
From
26.65 m
To
27.95 m
Hole Depth
150 m
Intercept Depth
26.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-15:26.65-27.95

Location

Easting
663423.39
Northing
5479547.18
Elevation
323.82 m
Azimuth
50 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“104”

Context: 1.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-15Crevier · tantalumGrade: 209Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-15
Project
Crevier
Commodity
tantalum
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
209
Grade Unit
ppm
Intercept
1 m
From
100.65 m
To
101.65 m
Hole Depth
150 m
Intercept Depth
26.65 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-15:100.65-101.65

Location

Easting
663423.39
Northing
5479547.18
Elevation
323.82 m
Azimuth
50 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows tantalum mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of tantalum as a secondary commodity

Negative factors

  • Very short intercept length
  • No true width disclosed

Evidence · table

“209”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · rare earth elementsGrade: 1618Grade Unit: ppmIntercept: 4.65 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1618
Grade Unit
ppm
Intercept
4.65 m
From
105.7 m
To
110.35 m
Hole Depth
381 m
Intercept Depth
105.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:105.7-110.35

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1618”

Context: 4.65

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-08Crevier · rare earth elementsGrade: 1353Grade Unit: ppmIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
1532-25-08
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1353
Grade Unit
ppm
Intercept
1.15 m
From
368.5 m
To
369.65 m
Hole Depth
381 m
Intercept Depth
105.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-08:368.5-369.65

Location

Easting
660550.21
Northing
5482902.26
Elevation
335.32 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1353”

Context: 1.15

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1676Grade Unit: ppmIntercept: 1.36 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1676
Grade Unit
ppm
Intercept
1.36 m
From
76.3 m
To
77.66 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:76.3-77.66

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1676”

Context: 1.36

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1868Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1868
Grade Unit
ppm
Intercept
2 m
From
93.65 m
To
95.65 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:93.65-95.65

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1868”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1091Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1091
Grade Unit
ppm
Intercept
1.2 m
From
112.6 m
To
113.8 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:112.6-113.8

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1091”

Context: 1.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1096Grade Unit: ppmIntercept: 3.25 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1096
Grade Unit
ppm
Intercept
3.25 m
From
174.2 m
To
177.45 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:174.2-177.45

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1096”

Context: 3.25

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1486Grade Unit: ppmIntercept: 6.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1486
Grade Unit
ppm
Intercept
6.1 m
From
179.7 m
To
185.8 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:179.7-185.8

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization over a good length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of rare earth elements as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“1486”

Context: 6.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1467Grade Unit: ppmIntercept: 9.35 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1467
Grade Unit
ppm
Intercept
9.35 m
From
188.1 m
To
197.45 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:188.1-197.45

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization over a good length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of rare earth elements as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“1467”

Context: 9.35

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1078Grade Unit: ppmIntercept: 4.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1078
Grade Unit
ppm
Intercept
4.05 m
From
212.55 m
To
216.6 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:212.55-216.6

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1078”

Context: 4.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1184Grade Unit: ppmIntercept: 1.65 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1184
Grade Unit
ppm
Intercept
1.65 m
From
219.25 m
To
220.9 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:219.25-220.9

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1184”

Context: 1.65

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-09Crevier · rare earth elementsGrade: 1453Grade Unit: ppmIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-09
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1453
Grade Unit
ppm
Intercept
1.1 m
From
342.3 m
To
343.4 m
Hole Depth
372 m
Intercept Depth
76.3 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-09:342.3-343.4

Location

Easting
660146.33
Northing
5483445.79
Elevation
317.49 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1453”

Context: 1.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1430Grade Unit: ppmIntercept: 12.55 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1430
Grade Unit
ppm
Intercept
12.55 m
From
11.7 m
To
24.25 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:11.7-24.25

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization over a good length, contributing to the polymetallic nature of the deposit.

Positive factors

  • Good intercept length
  • Presence of rare earth elements as a secondary commodity

Negative factors

  • No true width disclosed

Evidence · table

“1430”

Context: 12.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1351Grade Unit: ppmIntercept: 2.2 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1351
Grade Unit
ppm
Intercept
2.2 m
From
25.8 m
To
28 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:25.8-28

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1351”

Context: 2.20

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1111Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1111
Grade Unit
ppm
Intercept
1 m
From
31.65 m
To
32.65 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:31.65-32.65

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1111”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1181Grade Unit: ppmIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1181
Grade Unit
ppm
Intercept
1.1 m
From
69.2 m
To
70.3 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:69.2-70.3

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1181”

Context: 1.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1539Grade Unit: ppmIntercept: 2.15 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1539
Grade Unit
ppm
Intercept
2.15 m
From
71.8 m
To
73.95 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:71.8-73.95

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1539”

Context: 2.15

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1529Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1529
Grade Unit
ppm
Intercept
1 m
From
77.45 m
To
78.45 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:77.45-78.45

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1529”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1491Grade Unit: ppmIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1491
Grade Unit
ppm
Intercept
1.15 m
From
83.65 m
To
84.8 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:83.65-84.8

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1491”

Context: 1.15

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1696Grade Unit: ppmIntercept: 1.55 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1696
Grade Unit
ppm
Intercept
1.55 m
From
87.45 m
To
89 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:87.45-89

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1696”

Context: 1.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1644Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1644
Grade Unit
ppm
Intercept
1 m
From
103.25 m
To
104.25 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:103.25-104.25

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1644”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1428Grade Unit: ppmIntercept: 1.35 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1428
Grade Unit
ppm
Intercept
1.35 m
From
130.4 m
To
131.75 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:130.4-131.75

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1428”

Context: 1.35

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1380Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1380
Grade Unit
ppm
Intercept
1.05 m
From
161.25 m
To
162.3 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:161.25-162.3

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1380”

Context: 1.05

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1075Grade Unit: ppmIntercept: 3.55 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1075
Grade Unit
ppm
Intercept
3.55 m
From
167.65 m
To
171.2 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:167.65-171.2

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1075”

Context: 3.55

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1212Grade Unit: ppmIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1212
Grade Unit
ppm
Intercept
3.3 m
From
172.4 m
To
175.7 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:172.4-175.7

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1212”

Context: 3.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1082Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1082
Grade Unit
ppm
Intercept
2 m
From
180.9 m
To
182.9 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:180.9-182.9

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1082”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1082Grade Unit: ppmIntercept: 2.6 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1082
Grade Unit
ppm
Intercept
2.6 m
From
260.55 m
To
263.15 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:260.55-263.15

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1082”

Context: 2.60

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-10Crevier · rare earth elementsGrade: 1317Grade Unit: ppmIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
1532-25-10
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1317
Grade Unit
ppm
Intercept
1.7 m
From
339.1 m
To
340.8 m
Hole Depth
354 m
Intercept Depth
11.7 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-10:339.1-340.8

Location

Easting
660040.42
Northing
5483531.43
Elevation
308.73 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1317”

Context: 1.70

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-14Crevier · rare earth elementsGrade: 1053Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
1532-25-14
Project
Crevier
Commodity
rare earth elements
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1053
Grade Unit
ppm
Intercept
3 m
From
8.5 m
To
11.5 m
Hole Depth
150 m
Intercept Depth
8.5 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-14:8.5-11.5

Location

Easting
663664.82
Northing
5479316.19
Elevation
331.36 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows rare earth element mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of rare earth elements as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1053”

Context: 3.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1200Grade Unit: ppmIntercept: 1.1 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1200
Grade Unit
ppm
Intercept
1.1 m
From
9.4 m
To
10.5 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:9.4-10.5

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1200”

Context: 1.10

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1202Grade Unit: ppmIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1202
Grade Unit
ppm
Intercept
1.3 m
From
28.1 m
To
29.4 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:28.1-29.4

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1202”

Context: 1.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1440Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1440
Grade Unit
ppm
Intercept
1 m
From
39.15 m
To
40.15 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:39.15-40.15

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1440”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1221Grade Unit: ppmIntercept: 2.9 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1221
Grade Unit
ppm
Intercept
2.9 m
From
44.6 m
To
47.5 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:44.6-47.5

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1221”

Context: 2.90

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1352Grade Unit: ppmIntercept: 2.5 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1352
Grade Unit
ppm
Intercept
2.5 m
From
50 m
To
52.5 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:50-52.5

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1352”

Context: 2.50

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1475Grade Unit: ppmIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1475
Grade Unit
ppm
Intercept
2 m
From
55.2 m
To
57.2 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:55.2-57.2

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1475”

Context: 2.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1030Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1030
Grade Unit
ppm
Intercept
1 m
From
61 m
To
62 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:61-62

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows low strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Low grade compared to other intercepts
  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1030”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1228Grade Unit: ppmIntercept: 3.3 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1228
Grade Unit
ppm
Intercept
3.3 m
From
68.5 m
To
71.8 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:68.5-71.8

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1228”

Context: 3.30

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1540Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1540
Grade Unit
ppm
Intercept
1 m
From
74 m
To
75 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:74-75

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1540”

Context: 1.00

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1460Grade Unit: ppmIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1460
Grade Unit
ppm
Intercept
1.25 m
From
93.4 m
To
94.65 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:93.4-94.65

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1460”

Context: 1.25

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1107Grade Unit: ppmIntercept: 3.45 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1107
Grade Unit
ppm
Intercept
3.45 m
From
104.2 m
To
107.65 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:104.2-107.65

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1107”

Context: 3.45

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

1532-25-01Crevier · strontiumGrade: 1156Grade Unit: ppmIntercept: 3.75 mView all details
Link to this fact

Identity

Hole ID
1532-25-01
Project
Crevier
Commodity
strontium
Region
canada_qc
Reported Region
canada_qc
Ticker
NBY

Geometry

Grade
1156
Grade Unit
ppm
Intercept
3.75 m
From
115 m
To
118.75 m
Hole Depth
150 m
Intercept Depth
9.4 m

Classification

Program
exploration
Sample Type
drill
Group ID
1532-25-01:115-118.75

Location

Easting
663171.63
Northing
5479817.67
Elevation
347.4 m
Azimuth
230 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-18T00:00:00.000Z

Reasoning: This intercept shows strontium mineralization, adding to the polymetallic nature of the deposit.

Positive factors

  • Presence of strontium as a secondary commodity

Negative factors

  • Shorter intercept length
  • No true width disclosed

Evidence · table

“1156”

Context: 3.75

Tags used in scoring

No QA/QC Disclosurenegative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Why it applies: qaqc_disclosed is not true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The Crevier Project is located approximately 50 km north of the town of Girardville and approximately 150 km from the Ni"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.