NordX Metals Finds High-Grade Uranium Mineralization in Outcrop Samples up to 15.2% U3O8 at Flistjärn, Sweden and up to 6.95% U3O8 at the Norr Döttern Project, Sweden

Original announcement by cse on

Company
NordX Metals Corp.
Ticker
NRDX
Exchange
CSE
Region
Sweden
Primary commodity
Uranium
Secondary commodities
Molybdenum, Lead, Yttrium, Niobium, Zirconium, Silver, Zinc
Document categories
Drill results
Extracted
2026-09-22 13:18:33 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

NordX Metals announced high-grade uranium rock chip and boulder sample results from its Flistjärn and Norr Döttern projects in Sweden. Flistjärn samples returned up to 16.1% U3O8, confirming and extending historical mineralization, while Norr Döttern samples yielded up to 6.95% U3O8 from a historical trench. The company plans to convert these surface results into drill-ready targets, despite the early-stage nature of the sampling and limited company-level QA/QC.

Reasoning: NordX Metals reported very high-grade uranium surface samples from two projects in Sweden, confirming and extending known mineralization. While these are early-stage results from selective samples with limited company-level QA/QC, the grades are exceptional and indicate strong potential for future drilling targets. The explicit caution regarding historical data is noted.

Positive factors

  • High-grade uranium mineralization found in surface samples at both projects, with grades up to 16.1% U3O8 at Flistjärn and 6.95% U3O8 at Norr Döttern.
  • Confirmation and extension of historically documented mineralization at Flistjärn, and discovery of new high-grade zones.
  • Norr Döttern shows significant mineralization in a historical trench and multiple occurrences, with plans to convert surface results into drill-ready targets.
  • Qualified Person sign-off for the scientific and technical information.

Negative factors

  • Results are from surface rock chip and boulder samples, which are selective and do not establish in-situ mineralization.
  • No QA/QC measures (blanks, standards, duplicates) were inserted by the company, relying solely on lab internal procedures.
  • Uranium results from CRS Laboratories are reported as non-accredited determinations.
  • Historical drilling results are explicitly cautioned against reliance due to unconfirmed QA/QC.

Facts used in scoring: 41

Extracted facts

Stored fact records: 41. Some facts used in scoring do not have a stored record.

Drill Results (41)

Fact 1Flistjärn · uraniumGrade: 16.1Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Flistjärn
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
16.1
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Boulder sample
Easting
401382
Northing
7094790
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: An exceptionally high-grade boulder sample indicates strong potential, but its non-in-situ nature and non-accredited uranium assay reduce confidence.

Positive factors

  • Exceptional uranium grade (16.1% U3O8) from a surface sample, indicating high-grade potential.

Negative factors

  • Sample is a boulder, not in-situ bedrock, so source is unconfirmed.
  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“161079”

Context: T26437

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 16.1% U3O8 is an exceptionally high grade for uranium, well above the exceptional threshold of 2% U3O8.

Evidence · text

“angular boulder sample collected approximately 420m to the northwest assayed 16.1% U3O8”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 2Flistjärn · molybdenumGrade: 125Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
molybdenum
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
125
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Boulder sample
Easting
401382
Northing
7094790
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace molybdenum in a boulder sample is of low materiality.

Negative factors

  • Sample is a boulder, not in-situ bedrock, so source is unconfirmed.
  • Company did not insert its own QA/QC measures.

Evidence · table

“125”

Context: T26437

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 3Flistjärn · leadGrade: 10110Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
10110
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Boulder sample
Easting
401382
Northing
7094790
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in a boulder sample is of low materiality.

Negative factors

  • Sample is a boulder, not in-situ bedrock, so source is unconfirmed.
  • Company did not insert its own QA/QC measures.

Evidence · table

“10110”

Context: T26437

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 4Flistjärn · yttriumGrade: 1380Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
yttrium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
1380
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Boulder sample
Easting
401382
Northing
7094790
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace yttrium in a boulder sample is of low materiality.

Negative factors

  • Sample is a boulder, not in-situ bedrock, so source is unconfirmed.
  • Company did not insert its own QA/QC measures.

Evidence · table

“1380”

Context: T26437

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 5Flistjärn · niobiumGrade: 203Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
niobium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
203
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Boulder sample
Easting
401382
Northing
7094790
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace niobium in a boulder sample is of low materiality.

Negative factors

  • Sample is a boulder, not in-situ bedrock, so source is unconfirmed.
  • Company did not insert its own QA/QC measures.

Evidence · table

“203”

Context: T26437

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 6Flistjärn · zirconiumGrade: 706Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
706
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Boulder sample
Easting
401382
Northing
7094790
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in a boulder sample is of low materiality.

Negative factors

  • Sample is a boulder, not in-situ bedrock, so source is unconfirmed.
  • Company did not insert its own QA/QC measures.

Evidence · table

“706”

Context: T26437

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 7Flistjärn · uraniumGrade: 15.2Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Flistjärn
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
15.2
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094459
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: An exceptionally high-grade outcrop sample indicates strong in-situ potential, but non-accredited uranium assay and lack of company QA/QC reduce confidence.

Positive factors

  • Exceptional uranium grade (15.2% U3O8) from an outcrop sample, confirming in-situ high-grade mineralization.

Negative factors

  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“151881”

Context: T26436

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 15.2% U3O8 is an exceptionally high grade for uranium, well above the exceptional threshold of 2% U3O8.

Evidence · text

“Outcrop samples assayed 15.2% U3O8”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 8Flistjärn · molybdenumGrade: 292Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
molybdenum
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
292
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094459
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace molybdenum in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“292”

Context: T26436

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 9Flistjärn · leadGrade: 15720Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
15720
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094459
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“15720”

Context: T26436

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 10Flistjärn · yttriumGrade: 339Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
yttrium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
339
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094459
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace yttrium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“339”

Context: T26436

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 11Flistjärn · niobiumGrade: 1210Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
niobium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
1210
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094459
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace niobium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“1210”

Context: T26436

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 12Flistjärn · zirconiumGrade: 567Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
567
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094459
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“567”

Context: T26436

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 13Flistjärn · uraniumGrade: 11.7Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Flistjärn
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
11.7
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094458
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: An exceptionally high-grade outcrop sample indicates strong in-situ potential, but non-accredited uranium assay and lack of company QA/QC reduce confidence.

Positive factors

  • Exceptional uranium grade (11.7% U3O8) from an outcrop sample, confirming in-situ high-grade mineralization.

Negative factors

  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“116717”

Context: T26435

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 11.7% U3O8 is an exceptionally high grade for uranium, well above the exceptional threshold of 2% U3O8.

Evidence · text

“Outcrop samples assayed 15.2% U3O8 and 11.7% U3O8”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 14Flistjärn · molybdenumGrade: 349Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
molybdenum
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
349
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094458
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace molybdenum in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“349”

Context: T26435

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 15Flistjärn · leadGrade: 20420Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
20420
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094458
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“20420”

Context: T26435

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 16Flistjärn · yttriumGrade: 356Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
yttrium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
356
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094458
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace yttrium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“356”

Context: T26435

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 17Flistjärn · niobiumGrade: 849Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
niobium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
849
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094458
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace niobium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“849”

Context: T26435

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 18Flistjärn · zirconiumGrade: 631Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
631
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401641
Northing
7094458
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“631”

Context: T26435

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 19Flistjärn · uraniumGrade: 2.16Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Flistjärn
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
2.16
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401029
Northing
7094751
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: A strong grade from an outcrop sample is positive, but non-accredited uranium assay and lack of company QA/QC reduce confidence.

Positive factors

  • Strong uranium grade (2.16% U3O8) from an outcrop sample, indicating in-situ mineralization.

Negative factors

  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“21615”

Context: T26443

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 2.16% U3O8 is an exceptionally high grade for uranium, above the exceptional threshold of 2% U3O8.

Evidence · text

“T26443: 2.16% U3O8”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 20Flistjärn · molybdenumGrade: 3816Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
molybdenum
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
3816
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401029
Northing
7094751
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace molybdenum in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“3816”

Context: T26443

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 21Flistjärn · leadGrade: 3432Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
3432
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401029
Northing
7094751
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“3432”

Context: T26443

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 22Flistjärn · yttriumGrade: 68Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
yttrium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
68
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401029
Northing
7094751
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace yttrium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“68”

Context: T26443

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 23Flistjärn · niobiumGrade: 178Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
niobium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
178
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401029
Northing
7094751
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace niobium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“178”

Context: T26443

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 24Flistjärn · zirconiumGrade: 109Grade Unit: ppmView all details
Link to this fact

Identity

Project
Flistjärn
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
109
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
401029
Northing
7094751
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“109”

Context: T26443

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 25Norr Döttern · uraniumGrade: 6.95Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
6.95
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671437
Northing
7298364
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: An exceptionally high-grade outcrop sample from a historical trench is positive, but non-accredited uranium assay and lack of company QA/QC reduce confidence.

Positive factors

  • Exceptional uranium grade (6.95% U3O8) from an outcrop sample in a historical trench, indicating in-situ high-grade mineralization.

Negative factors

  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“69502”

Context: T26223

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

Bonanza InterceptRejected · positive

Exceptionally high-grade zone, well above the deposit-type norm.

Reason: 6.95% U3O8 is an exceptionally high grade for uranium, well above the exceptional threshold of 2% U3O8.

Evidence · text

“Outcrop samples returned up to 6.95%”

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 26Norr Döttern · silverGrade: 1Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
silver
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
1
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671437
Northing
7298364
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace silver in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“1”

Context: T26223

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 27Norr Döttern · zincGrade: 7725Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
zinc
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
7725
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671437
Northing
7298364
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zinc in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“7725”

Context: T26223

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 28Norr Döttern · leadGrade: 20550Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
20550
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671437
Northing
7298364
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“20550”

Context: T26223

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 29Norr Döttern · zirconiumGrade: 438Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
438
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671437
Northing
7298364
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“438”

Context: T26223

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 30Norr Döttern · uraniumGrade: 4.64Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
4.64
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
671429
Northing
7298353
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: An exceptionally high-grade outcrop sample is positive, but non-accredited uranium assay and lack of company QA/QC reduce confidence.

Positive factors

  • Exceptional uranium grade (4.64% U3O8) from an outcrop sample, indicating in-situ high-grade mineralization.

Negative factors

  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“46402”

Context: T26224

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 4.64% U3O8 is an exceptionally high grade for uranium, well above the exceptional threshold of 2% U3O8.

Evidence · text

“4.64%”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 31Norr Döttern · silverGrade: 3Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
silver
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
3
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
671429
Northing
7298353
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace silver in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“3”

Context: T26224

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 32Norr Döttern · zincGrade: 285Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
zinc
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
285
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
671429
Northing
7298353
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zinc in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“285”

Context: T26224

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 33Norr Döttern · leadGrade: 12520Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
12520
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
671429
Northing
7298353
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“12520”

Context: T26224

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 34Norr Döttern · zirconiumGrade: 294Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
294
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop
Easting
671429
Northing
7298353
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“294”

Context: T26224

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 35Norr Döttern · uraniumGrade: 2.28Grade Unit: % U3O8View all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
2.28
Grade Unit
% U3O8

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671438
Northing
7298358
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: A strong grade from an outcrop sample from a historical trench is positive, but non-accredited uranium assay and lack of company QA/QC reduce confidence.

Positive factors

  • Strong uranium grade (2.28% U3O8) from an outcrop sample in a historical trench, indicating in-situ mineralization.

Negative factors

  • Uranium results from CRS Laboratories are non-accredited determinations.
  • Company did not insert its own QA/QC measures.

Evidence · table

“22841”

Context: T26220

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: 2.28% U3O8 is an exceptionally high grade for uranium, above the exceptional threshold of 2% U3O8.

Evidence · text

“2.28%”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

No QA/QC DisclosureRejected · negative

Release does not disclose QA/QC — lab certification, CP/QP sign-off and assay protocols cannot be checked from this document.

Reason: The company explicitly stated that no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company.

Evidence · text

“Because the sampling was non- systematic and intended only for early-stage geochemical indications, no QA/QC measures such as blanks, standards, or field duplicates were inserted into the sample stream by the Company”
Fact 36Norr Döttern · silverGrade: 2Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
silver
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
2
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671438
Northing
7298358
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace silver in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“2”

Context: T26220

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 37Norr Döttern · zincGrade: 3441Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
zinc
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
3441
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671438
Northing
7298358
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zinc in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“3441”

Context: T26220

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 38Norr Döttern · leadGrade: 7825Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
lead
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
7825
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671438
Northing
7298358
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace lead in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“7825”

Context: T26220

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 39Norr Döttern · zirconiumGrade: 549Grade Unit: ppmView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
zirconium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
549
Grade Unit
ppm

Classification

Sample Type
surface

Location

Location
Outcrop from historical trench ND2
Easting
671438
Northing
7298358
CRS
SWEREF 99 TM
Loc. Source
document

QA/QC

Laboratory
CRS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Trace zirconium in an outcrop sample is of low materiality.

Negative factors

  • Company did not insert its own QA/QC measures.

Evidence · table

“549”

Context: T26220

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Fact 40Norr Döttern · uraniumGrade: 0.1Grade Unit: % U3O8Intercept: 11.9 mHistorical resultNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
0.1
Grade Unit
% U3O8
Intercept
11.9 m
From
18.6 m
To
30.5 m
Intercept Depth
18.6 m

Classification

Sample Type
drill
Group ID
Norr_Döttern:18.6-30.5

Location

Location
Långträsk ("LG")
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
Yes

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
Yes

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Historical drill intercept with low confidence due to explicit company caution regarding data reliability.

Negative factors

  • Historical data with explicit caution against reliance due to unconfirmed QA/QC.
  • Grade is below the weak threshold for uranium (0.03% U3O8) but over a significant width.

Evidence · text

“Drilling intercepted up to 11.9m grading 0.1% U3O8 from 18.6m downhole at Långträsk ("LG")”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

Fact 41Norr Döttern · uraniumGrade: 0.19Grade Unit: % U3O8Intercept: 4 mHistorical resultNeeds review: drill_no_hole_idView all details
Link to this fact

Identity

Project
Norr Döttern
Commodity
uranium
Region
sweden
Reported Region
sweden
Ticker
NRDX

Geometry

Grade
0.19
Grade Unit
% U3O8
Intercept
4 m
From
66 m
To
70 m
Intercept Depth
66 m

Classification

Sample Type
drill
Group ID
Norr_Döttern:66-70

Location

Location
Norr Döttern 1 ("ND1")
Loc. Source
document

QA/QC

QA/QC Disclosed
Yes
QP Signed
Yes

Review

Needs Review
Yes
Review Reason
drill_no_hole_id
Interp. Status
low_confidence
Historical
Yes

Dates

Event date
2026-09-22T00:00:00.000Z

Reasoning: Historical drill intercept with low confidence due to explicit company caution regarding data reliability.

Negative factors

  • Historical data with explicit caution against reliance due to unconfirmed QA/QC.
  • Grade is above the weak threshold for uranium (0.03% U3O8) but over a narrow width.

Evidence · text

“and 4m at 0.19% U3O8 from 66m downhole at Norr Döttern 1 ("ND1")”

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.