Orosur Mining Inc - El Pantano Project Developing
Original announcement by tmx on
- Company
- Orosur Mining Inc
- Ticker
- OMI
- Exchange
- TSX
- Region
- Santa Cruz province, southern Argentina
- Primary commodity
- Gold
- Secondary commodities
- Copper, Arsenic
- Document categories
- Drill results, Agreement transaction
- Extracted
- 2026-09-18 14:44:58 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Orosur Mining Inc. announced the results of its first-ever drill program at the El Pantano project in Argentina, confirming a low-sulphidation epithermal gold/silver system. The company has also secured 100% ownership of the project by completing its JV obligations. While most gold intercepts are low-grade, the program successfully identified structurally controlled gold-bearing vein corridors and pathfinder-rich alteration zones, providing vectors for future exploration.
Reasoning: The document reports the first drill results from the El Pantano project, confirming the presence of an epithermal system and securing 100% ownership. While grades are generally low, the results are significant for an early-stage exploration project. The lack of true width information is a notable drawback.
Positive factors
- First-ever drilling program on the project, confirming an epithermal system.
- Company secured 100% ownership of the project by meeting JV obligations.
- QA/QC protocols and QP sign-off are disclosed.
Negative factors
- Most gold grades are low, with few intervals exceeding the weak threshold for epithermal deposits.
- True thicknesses of intercepts are unknown, limiting geological interpretation.
- Arsenic is noted as a pathfinder, which could indicate potential processing challenges if present in economic quantities.
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 115
Extracted facts
Stored fact records: 114. Some facts used in scoring do not have a stored record.
Drill Results (114)
ELP-001El Pantano West · goldGrade: 0.14Grade Unit: g/tIntercept: 63 mView all detailsHide details
Identity
- Hole ID
- ELP-001
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.14
- Grade Unit
- g/t
- Intercept
- 63 m
- From
- 0 m
- To
- 63 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-001:0-63
- Mining Method
- unknown
Location
- Easting
- 527906
- Northing
- 4697061
- CRS
- WGS84 UTM Zone 18
- Elevation
- 285 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a wide interval but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant on its own.
Positive factors
- Wide intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.14”
Context: 63
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-001El Pantano West · copperGrade: 704Grade Unit: ppmIntercept: 63 mView all detailsHide details
Identity
- Hole ID
- ELP-001
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 704
- Grade Unit
- ppm
- Intercept
- 63 m
- From
- 0 m
- To
- 63 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-001:0-63
- Mining Method
- unknown
Location
- Easting
- 527906
- Northing
- 4697061
- CRS
- WGS84 UTM Zone 18
- Elevation
- 285 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts rather than economic mineralization. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (704 ppm = 0.07%), not economically significant.
- True thickness is unknown.
Evidence · table
“704”
Context: 63
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-001El Pantano West · goldGrade: 0.86Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- ELP-001
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 27.9 m
- To
- 28.5 m
- Intercept Depth
- 27.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-001:27.9-28.5
- Mining Method
- unknown
Location
- Easting
- 527906
- Northing
- 4697061
- CRS
- WGS84 UTM Zone 18
- Elevation
- 285 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This narrow sub-interval shows a moderate gold grade, indicating localized mineralization within the broader low-grade zone. Its narrowness limits its individual significance.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“0.86”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-001El Pantano West · copperGrade: 1457Grade Unit: ppmIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- ELP-001
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1457
- Grade Unit
- ppm
- Intercept
- 0.6 m
- From
- 27.9 m
- To
- 28.5 m
- Intercept Depth
- 27.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-001:27.9-28.5
- Mining Method
- unknown
Location
- Easting
- 527906
- Northing
- 4697061
- CRS
- WGS84 UTM Zone 18
- Elevation
- 285 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1457 ppm = 0.14%), not economically significant.
- True thickness is unknown.
Evidence · table
“1457”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-002El Pantano West · goldGrade: 0.11Grade Unit: g/tIntercept: 20.6 mView all detailsHide details
Identity
- Hole ID
- ELP-002
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 20.6 m
- From
- 244 m
- To
- 264.6 m
- Intercept Depth
- 244 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-002:244-264.6
- Mining Method
- unknown
Location
- Easting
- 527970
- Northing
- 4697238
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a moderate width but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Moderate intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.11”
Context: 20.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-002El Pantano West · copperGrade: 892Grade Unit: ppmIntercept: 20.6 mView all detailsHide details
Identity
- Hole ID
- ELP-002
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 892
- Grade Unit
- ppm
- Intercept
- 20.6 m
- From
- 244 m
- To
- 264.6 m
- Intercept Depth
- 244 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-002:244-264.6
- Mining Method
- unknown
Location
- Easting
- 527970
- Northing
- 4697238
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (892 ppm = 0.089%), not economically significant.
- True thickness is unknown.
Evidence · table
“892”
Context: 20.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-003El Pantano West · goldGrade: 0.46Grade Unit: g/tIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- ELP-003
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 18 m
- From
- 180 m
- To
- 198 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-003:180-198
- Mining Method
- unknown
Location
- Easting
- 528007
- Northing
- 4697338
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a reasonable width, making it one of the better results in the program and supporting the presence of gold mineralization.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
- Moderate intercept length.
Negative factors
- True thickness is unknown.
Evidence · table
“0.46”
Context: 18
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-003El Pantano West · copperGrade: 107Grade Unit: ppmIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- ELP-003
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 107
- Grade Unit
- ppm
- Intercept
- 18 m
- From
- 180 m
- To
- 198 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-003:180-198
- Mining Method
- unknown
Location
- Easting
- 528007
- Northing
- 4697338
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (107 ppm = 0.01%), not economically significant.
- True thickness is unknown.
Evidence · table
“107”
Context: 18
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-003El Pantano West · goldGrade: 0.79Grade Unit: g/tIntercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- ELP-003
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.79
- Grade Unit
- g/t
- Intercept
- 4.9 m
- From
- 188 m
- To
- 192.9 m
- Intercept Depth
- 188 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-003:188-192.9
- Mining Method
- unknown
Location
- Easting
- 528007
- Northing
- 4697338
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This sub-interval shows a good gold grade over a narrow width, highlighting a higher-grade zone within the broader intercept and supporting the presence of gold mineralization.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- True thickness is unknown.
Evidence · table
“0.79”
Context: 4.9
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-003El Pantano West · copperGrade: 260Grade Unit: ppmIntercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- ELP-003
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 260
- Grade Unit
- ppm
- Intercept
- 4.9 m
- From
- 188 m
- To
- 192.9 m
- Intercept Depth
- 188 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-003:188-192.9
- Mining Method
- unknown
Location
- Easting
- 528007
- Northing
- 4697338
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 190 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (260 ppm = 0.026%), not economically significant.
- True thickness is unknown.
Evidence · table
“260”
Context: 4.9
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-006El Pantano West · goldGrade: 0.27Grade Unit: g/tIntercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- ELP-006
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 54.8 m
- From
- 0 m
- To
- 54.8 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-006:0-54.8
- Mining Method
- unknown
Location
- Easting
- 527831
- Northing
- 4697342
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a wide interval but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant on its own.
Positive factors
- Wide intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.27”
Context: 54.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-006El Pantano West · copperGrade: 1025Grade Unit: ppmIntercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- ELP-006
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1025
- Grade Unit
- ppm
- Intercept
- 54.8 m
- From
- 0 m
- To
- 54.8 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-006:0-54.8
- Mining Method
- unknown
Location
- Easting
- 527831
- Northing
- 4697342
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1025 ppm = 0.1%), not economically significant.
- True thickness is unknown.
Evidence · table
“1025”
Context: 54.8
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-006El Pantano West · goldGrade: 1.3Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- ELP-006
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1.3
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 21.4 m
- To
- 22 m
- Intercept Depth
- 21.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-006:21.4-22
- Mining Method
- unknown
Location
- Easting
- 527831
- Northing
- 4697342
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow sub-interval shows a good gold grade, highlighting a higher-grade zone within the broader low-grade intercept. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the moderate threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“1.3”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-006El Pantano West · copperGrade: 941Grade Unit: ppmIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- ELP-006
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 941
- Grade Unit
- ppm
- Intercept
- 0.6 m
- From
- 21.4 m
- To
- 22 m
- Intercept Depth
- 21.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-006:21.4-22
- Mining Method
- unknown
Location
- Easting
- 527831
- Northing
- 4697342
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (941 ppm = 0.09%), not economically significant.
- True thickness is unknown.
Evidence · table
“941”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-006El Pantano West · goldGrade: 0.2Grade Unit: g/tIntercept: 13.7 mView all detailsHide details
Identity
- Hole ID
- ELP-006
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 13.7 m
- From
- 105.8 m
- To
- 119.5 m
- Intercept Depth
- 105.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-006:105.8-119.5
- Mining Method
- unknown
Location
- Easting
- 527831
- Northing
- 4697342
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a moderate width but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Moderate intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.2”
Context: 13.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-006El Pantano West · copperGrade: 898Grade Unit: ppmIntercept: 13.7 mView all detailsHide details
Identity
- Hole ID
- ELP-006
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 898
- Grade Unit
- ppm
- Intercept
- 13.7 m
- From
- 105.8 m
- To
- 119.5 m
- Intercept Depth
- 105.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-006:105.8-119.5
- Mining Method
- unknown
Location
- Easting
- 527831
- Northing
- 4697342
- CRS
- WGS84 UTM Zone 18
- Elevation
- 266 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (898 ppm = 0.089%), not economically significant.
- True thickness is unknown.
Evidence · table
“898”
Context: 13.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-016El Pantano West · goldGrade: 0.15Grade Unit: g/tIntercept: 6.6 mView all detailsHide details
Identity
- Hole ID
- ELP-016
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 6.6 m
- From
- 41.4 m
- To
- 48 m
- Intercept Depth
- 41.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-016:41.4-48
- Mining Method
- unknown
Location
- Easting
- 542357
- Northing
- 4686778
- CRS
- WGS84 UTM Zone 18
- Elevation
- 281 m
- Azimuth
- 200 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.15”
Context: 6.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-016El Pantano West · copperGrade: 57Grade Unit: ppmIntercept: 6.6 mView all detailsHide details
Identity
- Hole ID
- ELP-016
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 57
- Grade Unit
- ppm
- Intercept
- 6.6 m
- From
- 41.4 m
- To
- 48 m
- Intercept Depth
- 41.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-016:41.4-48
- Mining Method
- unknown
Location
- Easting
- 542357
- Northing
- 4686778
- CRS
- WGS84 UTM Zone 18
- Elevation
- 281 m
- Azimuth
- 200 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (57 ppm = 0.0057%), not economically significant.
- True thickness is unknown.
Evidence · table
“57”
Context: 6.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-017AEl Pantano West · goldGrade: 0.23Grade Unit: g/tIntercept: 3.45 mView all detailsHide details
Identity
- Hole ID
- ELP-017A
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 3.45 m
- From
- 91.55 m
- To
- 95 m
- Intercept Depth
- 91.55 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-017A:91.55-95
- Mining Method
- unknown
Location
- Easting
- 542401
- Northing
- 4686872
- CRS
- WGS84 UTM Zone 18
- Elevation
- 273 m
- Azimuth
- 200 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.23”
Context: 3.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-017AEl Pantano West · copperGrade: 78Grade Unit: ppmIntercept: 3.45 mView all detailsHide details
Identity
- Hole ID
- ELP-017A
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 78
- Grade Unit
- ppm
- Intercept
- 3.45 m
- From
- 91.55 m
- To
- 95 m
- Intercept Depth
- 91.55 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-017A:91.55-95
- Mining Method
- unknown
Location
- Easting
- 542401
- Northing
- 4686872
- CRS
- WGS84 UTM Zone 18
- Elevation
- 273 m
- Azimuth
- 200 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (78 ppm = 0.0078%), not economically significant.
- True thickness is unknown.
Evidence · table
“78”
Context: 3.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.24Grade Unit: g/tIntercept: 4.4 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 4.4 m
- From
- 118.3 m
- To
- 122.7 m
- Intercept Depth
- 118.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:118.3-122.7
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.24”
Context: 4.4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 895Grade Unit: ppmIntercept: 4.4 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 895
- Grade Unit
- ppm
- Intercept
- 4.4 m
- From
- 118.3 m
- To
- 122.7 m
- Intercept Depth
- 118.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:118.3-122.7
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (895 ppm = 0.089%), not economically significant.
- True thickness is unknown.
Evidence · table
“895”
Context: 4.4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.29Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 3.3 m
- From
- 215.7 m
- To
- 219 m
- Intercept Depth
- 215.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:215.7-219
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.29”
Context: 3.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 225Grade Unit: ppmIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 225
- Grade Unit
- ppm
- Intercept
- 3.3 m
- From
- 215.7 m
- To
- 219 m
- Intercept Depth
- 215.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:215.7-219
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (225 ppm = 0.02%), not economically significant.
- True thickness is unknown.
Evidence · table
“225”
Context: 3.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.71Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.71
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 217.8 m
- To
- 218.65 m
- Intercept Depth
- 217.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:217.8-218.65
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow sub-interval shows a good gold grade, highlighting a higher-grade zone within the broader intercept. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“0.71”
Context: 0.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 212Grade Unit: ppmIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 212
- Grade Unit
- ppm
- Intercept
- 0.85 m
- From
- 217.8 m
- To
- 218.65 m
- Intercept Depth
- 217.8 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:217.8-218.65
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (212 ppm = 0.02%), not economically significant.
- True thickness is unknown.
Evidence · table
“212”
Context: 0.85
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.27Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 247 m
- To
- 249.5 m
- Intercept Depth
- 247 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:247-249.5
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.27”
Context: 2.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 1500Grade Unit: ppmIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1500
- Grade Unit
- ppm
- Intercept
- 2.5 m
- From
- 247 m
- To
- 249.5 m
- Intercept Depth
- 247 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:247-249.5
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1500 ppm = 0.15%), not economically significant.
- True thickness is unknown.
Evidence · table
“1500”
Context: 2.5
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.66Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.66
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 248 m
- To
- 248.6 m
- Intercept Depth
- 248 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:248-248.6
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow sub-interval shows a good gold grade, highlighting a higher-grade zone within the broader intercept. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“0.66”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 2848Grade Unit: ppmIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 2848
- Grade Unit
- ppm
- Intercept
- 0.6 m
- From
- 248 m
- To
- 248.6 m
- Intercept Depth
- 248 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:248-248.6
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (2848 ppm = 0.28%), not economically significant.
- True thickness is unknown.
Evidence · table
“2848”
Context: 0.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.18Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 259 m
- To
- 263 m
- Intercept Depth
- 259 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:259-263
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.18”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 1126Grade Unit: ppmIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1126
- Grade Unit
- ppm
- Intercept
- 4 m
- From
- 259 m
- To
- 263 m
- Intercept Depth
- 259 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:259-263
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1126 ppm = 0.11%), not economically significant.
- True thickness is unknown.
Evidence · table
“1126”
Context: 4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.15Grade Unit: g/tIntercept: 15.13 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 15.13 m
- From
- 278.4 m
- To
- 293.53 m
- Intercept Depth
- 278.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:278.4-293.53
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a moderate width but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Moderate intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.15”
Context: 15.13
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 959Grade Unit: ppmIntercept: 15.13 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 959
- Grade Unit
- ppm
- Intercept
- 15.13 m
- From
- 278.4 m
- To
- 293.53 m
- Intercept Depth
- 278.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:278.4-293.53
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (959 ppm = 0.09%), not economically significant.
- True thickness is unknown.
Evidence · table
“959”
Context: 15.13
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.59Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.59
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 305.7 m
- To
- 306.8 m
- Intercept Depth
- 305.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:305.7-306.8
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow intercept shows a good gold grade, indicating localized mineralization. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“0.59”
Context: 1.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 691Grade Unit: ppmIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 691
- Grade Unit
- ppm
- Intercept
- 1.1 m
- From
- 305.7 m
- To
- 306.8 m
- Intercept Depth
- 305.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:305.7-306.8
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (691 ppm = 0.069%), not economically significant.
- True thickness is unknown.
Evidence · table
“691”
Context: 1.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 1.13Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1.13
- Grade Unit
- g/t
- Intercept
- 0.4 m
- From
- 306.4 m
- To
- 306.8 m
- Intercept Depth
- 306.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:306.4-306.8
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow sub-interval shows a good gold grade, highlighting a higher-grade zone within the broader intercept. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the moderate threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“1.13”
Context: 0.4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 742Grade Unit: ppmIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 742
- Grade Unit
- ppm
- Intercept
- 0.4 m
- From
- 306.4 m
- To
- 306.8 m
- Intercept Depth
- 306.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:306.4-306.8
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (742 ppm = 0.07%), not economically significant.
- True thickness is unknown.
Evidence · table
“742”
Context: 0.4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.2Grade Unit: g/tIntercept: 27.12 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 27.12 m
- From
- 316 m
- To
- 343.12 m
- Intercept Depth
- 316 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:316-343.12
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a wide interval but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Wide intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.2”
Context: 27.12
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 917Grade Unit: ppmIntercept: 27.12 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 917
- Grade Unit
- ppm
- Intercept
- 27.12 m
- From
- 316 m
- To
- 343.12 m
- Intercept Depth
- 316 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:316-343.12
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (917 ppm = 0.09%), not economically significant.
- True thickness is unknown.
Evidence · table
“917”
Context: 27.12
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.39Grade Unit: g/tIntercept: 2.18 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 2.18 m
- From
- 325.82 m
- To
- 328 m
- Intercept Depth
- 325.82 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:325.82-328
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This narrow sub-interval shows a good gold grade, highlighting a higher-grade zone within the broader intercept. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- True thickness is unknown.
Evidence · table
“0.39”
Context: 2.18
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 1263Grade Unit: ppmIntercept: 2.18 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1263
- Grade Unit
- ppm
- Intercept
- 2.18 m
- From
- 325.82 m
- To
- 328 m
- Intercept Depth
- 325.82 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:325.82-328
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1263 ppm = 0.12%), not economically significant.
- True thickness is unknown.
Evidence · table
“1263”
Context: 2.18
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · goldGrade: 0.61Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.61
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 339.9 m
- To
- 340.2 m
- Intercept Depth
- 339.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:339.9-340.2
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow sub-interval shows a good gold grade, highlighting a higher-grade zone within the broader intercept. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“0.61”
Context: 0.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-018El Pantano West · copperGrade: 3558Grade Unit: ppmIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- ELP-018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 3558
- Grade Unit
- ppm
- Intercept
- 0.3 m
- From
- 339.9 m
- To
- 340.2 m
- Intercept Depth
- 339.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-018:339.9-340.2
- Mining Method
- unknown
Location
- Easting
- 527761
- Northing
- 4696716
- CRS
- WGS84 UTM Zone 18
- Elevation
- 320 m
- Azimuth
- 10 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (3558 ppm = 0.35%), not economically significant.
- True thickness is unknown.
Evidence · table
“3558”
Context: 0.3
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-020El Pantano West · goldGrade: 0.21Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- ELP-020
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 107 m
- To
- 108.45 m
- Intercept Depth
- 107 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-020:107-108.45
- Mining Method
- unknown
Location
- Easting
- 527739
- Northing
- 4696947
- CRS
- WGS84 UTM Zone 18
- Elevation
- 318 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a very narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.21”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-020El Pantano West · copperGrade: 1009Grade Unit: ppmIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- ELP-020
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1009
- Grade Unit
- ppm
- Intercept
- 1.45 m
- From
- 107 m
- To
- 108.45 m
- Intercept Depth
- 107 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-020:107-108.45
- Mining Method
- unknown
Location
- Easting
- 527739
- Northing
- 4696947
- CRS
- WGS84 UTM Zone 18
- Elevation
- 318 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1009 ppm = 0.1%), not economically significant.
- True thickness is unknown.
Evidence · table
“1009”
Context: 1.45
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-021El Pantano West · goldGrade: 0.4Grade Unit: g/tIntercept: 1.65 mView all detailsHide details
Identity
- Hole ID
- ELP-021
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 1.65 m
- From
- 134 m
- To
- 135.65 m
- Intercept Depth
- 134 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-021:134-135.65
- Mining Method
- unknown
Location
- Easting
- 527879
- Northing
- 4696768
- CRS
- WGS84 UTM Zone 18
- Elevation
- 290 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This very narrow intercept shows a good gold grade, indicating localized mineralization. Its narrowness limits its individual significance but is positive for early exploration.
Positive factors
- Gold grade is above the weak threshold for epithermal deposits.
Negative factors
- Very narrow intercept length.
- True thickness is unknown.
Evidence · table
“0.4”
Context: 1.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-021El Pantano West · copperGrade: 1745Grade Unit: ppmIntercept: 1.65 mView all detailsHide details
Identity
- Hole ID
- ELP-021
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1745
- Grade Unit
- ppm
- Intercept
- 1.65 m
- From
- 134 m
- To
- 135.65 m
- Intercept Depth
- 134 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-021:134-135.65
- Mining Method
- unknown
Location
- Easting
- 527879
- Northing
- 4696768
- CRS
- WGS84 UTM Zone 18
- Elevation
- 290 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (1745 ppm = 0.17%), not economically significant.
- True thickness is unknown.
Evidence · table
“1745”
Context: 1.65
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-022El Pantano West · goldGrade: 0.21Grade Unit: g/tIntercept: 2.25 mView all detailsHide details
Identity
- Hole ID
- ELP-022
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 2.25 m
- From
- 179.75 m
- To
- 182 m
- Intercept Depth
- 179.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-022:179.75-182
- Mining Method
- unknown
Location
- Easting
- 527665
- Northing
- 4696985
- CRS
- WGS84 UTM Zone 18
- Elevation
- 285 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a very narrow width and very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.21”
Context: 2.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-022El Pantano West · copperGrade: 427Grade Unit: ppmIntercept: 2.25 mView all detailsHide details
Identity
- Hole ID
- ELP-022
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 427
- Grade Unit
- ppm
- Intercept
- 2.25 m
- From
- 179.75 m
- To
- 182 m
- Intercept Depth
- 179.75 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-022:179.75-182
- Mining Method
- unknown
Location
- Easting
- 527665
- Northing
- 4696985
- CRS
- WGS84 UTM Zone 18
- Elevation
- 285 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (427 ppm = 0.04%), not economically significant.
- True thickness is unknown.
Evidence · table
“427”
Context: 2.25
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-023El Pantano West · goldGrade: 0.14Grade Unit: g/tIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- ELP-023
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.14
- Grade Unit
- g/t
- Intercept
- 27 m
- From
- 100 m
- To
- 127 m
- Intercept Depth
- 100 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-023:100-127
- Mining Method
- unknown
Location
- Easting
- 528418
- Northing
- 4696839
- CRS
- WGS84 UTM Zone 18
- Elevation
- 280 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a wide interval but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Wide intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.14”
Context: 27
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-023El Pantano West · copperGrade: 734Grade Unit: ppmIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- ELP-023
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 734
- Grade Unit
- ppm
- Intercept
- 27 m
- From
- 100 m
- To
- 127 m
- Intercept Depth
- 100 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-023:100-127
- Mining Method
- unknown
Location
- Easting
- 528418
- Northing
- 4696839
- CRS
- WGS84 UTM Zone 18
- Elevation
- 280 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (734 ppm = 0.07%), not economically significant.
- True thickness is unknown.
Evidence · table
“734”
Context: 27
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-023El Pantano West · goldGrade: 0.13Grade Unit: g/tIntercept: 23.6 mView all detailsHide details
Identity
- Hole ID
- ELP-023
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 23.6 m
- From
- 201.5 m
- To
- 225.1 m
- Intercept Depth
- 201.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-023:201.5-225.1
- Mining Method
- unknown
Location
- Easting
- 528418
- Northing
- 4696839
- CRS
- WGS84 UTM Zone 18
- Elevation
- 280 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a moderate width but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Moderate intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.13”
Context: 23.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-023El Pantano West · copperGrade: 545Grade Unit: ppmIntercept: 23.6 mView all detailsHide details
Identity
- Hole ID
- ELP-023
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 545
- Grade Unit
- ppm
- Intercept
- 23.6 m
- From
- 201.5 m
- To
- 225.1 m
- Intercept Depth
- 201.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-023:201.5-225.1
- Mining Method
- unknown
Location
- Easting
- 528418
- Northing
- 4696839
- CRS
- WGS84 UTM Zone 18
- Elevation
- 280 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (545 ppm = 0.05%), not economically significant.
- True thickness is unknown.
Evidence · table
“545”
Context: 23.6
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-023El Pantano West · goldGrade: 0.12Grade Unit: g/tIntercept: 20.7 mView all detailsHide details
Identity
- Hole ID
- ELP-023
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
- Intercept
- 20.7 m
- From
- 244.3 m
- To
- 265 m
- Intercept Depth
- 244.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-023:244.3-265
- Mining Method
- unknown
Location
- Easting
- 528418
- Northing
- 4696839
- CRS
- WGS84 UTM Zone 18
- Elevation
- 280 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This intercept shows a moderate width but very low gold grade, falling below the weak threshold for epithermal deposits. It contributes to understanding the system's footprint but is not economically significant.
Positive factors
- Moderate intercept length for an early-stage exploration hole.
Negative factors
- Gold grade is below the weak threshold for epithermal deposits.
- True thickness is unknown.
Evidence · table
“0.12”
Context: 20.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-023El Pantano West · copperGrade: 700Grade Unit: ppmIntercept: 20.7 mView all detailsHide details
Identity
- Hole ID
- ELP-023
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 700
- Grade Unit
- ppm
- Intercept
- 20.7 m
- From
- 244.3 m
- To
- 265 m
- Intercept Depth
- 244.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- ELP-023:244.3-265
- Mining Method
- unknown
Location
- Easting
- 528418
- Northing
- 4696839
- CRS
- WGS84 UTM Zone 18
- Elevation
- 280 m
- Azimuth
- 20 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: The copper grade is very low, indicating trace amounts. It provides geochemical context for the epithermal system.
Negative factors
- Copper grade is a trace amount (700 ppm = 0.07%), not economically significant.
- True thickness is unknown.
Evidence · table
“700”
Context: 20.7
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-015El Pantano West · arsenicGrade: 232Grade Unit: ppmIntercept: 125.5 mView all detailsHide details
Identity
- Hole ID
- ELP-015
- Project
- El Pantano West
- Commodity
- arsenic
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 232
- Grade Unit
- ppm
- Intercept
- 125.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Mining Method
- unknown
Location
- Easting
- 541411
- Northing
- 4688376
- CRS
- WGS84 UTM Zone 18
- Elevation
- 317 m
- Azimuth
- 200 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This wide intercept of arsenic is significant as a pathfinder element, supporting the presence of a hydrothermal system in the eastern domain. However, arsenic itself is not an economic commodity and can be deleterious.
Positive factors
- Wide intercept length for a pathfinder element.
Negative factors
- Arsenic is a pathfinder, not an economic commodity, and can be a deleterious element.
- True thickness is unknown.
Evidence · text
“DH_ELP015 with 125.5 m at 232 ppm As”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
ELP-014El Pantano West · arsenicGrade: 174Grade Unit: ppmIntercept: 60.85 mView all detailsHide details
Identity
- Hole ID
- ELP-014
- Project
- El Pantano West
- Commodity
- arsenic
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 174
- Grade Unit
- ppm
- Intercept
- 60.85 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Mining Method
- unknown
Location
- Easting
- 541338
- Northing
- 4688175
- CRS
- WGS84 UTM Zone 18
- Elevation
- 342 m
- Azimuth
- 200 °
- Dip
- -50 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Compositing
- Cutoff Grade
- 0.3
- Cutoff Unit
- g/t
- Max Dilution
- 3 m
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: This moderate intercept of arsenic is significant as a pathfinder element, supporting the presence of a hydrothermal system in the eastern domain. However, arsenic itself is not an economic commodity and can be deleterious.
Positive factors
- Moderate intercept length for a pathfinder element.
Negative factors
- Arsenic is a pathfinder, not an economic commodity, and can be a deleterious element.
- True thickness is unknown.
Evidence · text
“DH_ELP014 with 60.85 m at 174 ppm As”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
DH_ELP001El Pantano West · goldGrade: 0.14Grade Unit: g/tIntercept: 63 mView all detailsHide details
Identity
- Hole ID
- DH_ELP001
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.14
- Grade Unit
- g/t
- Intercept
- 63 m
- From
- 0 m
- To
- 63 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP001:0-63
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.14 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 8.8 g/t·m is below.
Negative factors
- 0.14 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.14”
Context: DH_ELP001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP001El Pantano West · copperGrade: 704Grade Unit: ppmIntercept: 63 mView all detailsHide details
Identity
- Hole ID
- DH_ELP001
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 704
- Grade Unit
- ppm
- Intercept
- 63 m
- From
- 0 m
- To
- 63 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP001:0-63
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 704 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“704”
Context: DH_ELP001
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP001El Pantano West · goldGrade: 0.86Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP001
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 27.9 m
- To
- 28.5 m
- Intercept Depth
- 27.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP001:27.9-28.5
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.86 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.86”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP001El Pantano West · copperGrade: 1457Grade Unit: ppmIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP001
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1457
- Grade Unit
- ppm
- Intercept
- 0.6 m
- From
- 27.9 m
- To
- 28.5 m
- Intercept Depth
- 27.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP001:27.9-28.5
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1457 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1457”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP002El Pantano West · goldGrade: 0.11Grade Unit: g/tIntercept: 20.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP002
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 20.6 m
- From
- 244 m
- To
- 264.6 m
- Intercept Depth
- 244 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP002:244-264.6
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.3 g/t·m is below.
Negative factors
- 0.11 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: DH_ELP002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP002El Pantano West · copperGrade: 892Grade Unit: ppmIntercept: 20.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP002
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 892
- Grade Unit
- ppm
- Intercept
- 20.6 m
- From
- 244 m
- To
- 264.6 m
- Intercept Depth
- 244 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP002:244-264.6
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 892 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“892”
Context: DH_ELP002
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP003El Pantano West · goldGrade: 0.46Grade Unit: g/tIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- DH_ELP003
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.46
- Grade Unit
- g/t
- Intercept
- 18 m
- From
- 180 m
- To
- 198 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP003:180-198
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.46 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 8.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.46”
Context: DH_ELP003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP003El Pantano West · copperGrade: 107Grade Unit: ppmIntercept: 18 mView all detailsHide details
Identity
- Hole ID
- DH_ELP003
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 107
- Grade Unit
- ppm
- Intercept
- 18 m
- From
- 180 m
- To
- 198 m
- Intercept Depth
- 180 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP003:180-198
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 107 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“107”
Context: DH_ELP003
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP003El Pantano West · goldGrade: 0.79Grade Unit: g/tIntercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- DH_ELP003
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.79
- Grade Unit
- g/t
- Intercept
- 4.9 m
- From
- 188 m
- To
- 192.9 m
- Intercept Depth
- 188 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP003:188-192.9
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.79 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.79”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP003El Pantano West · copperGrade: 260Grade Unit: ppmIntercept: 4.9 mView all detailsHide details
Identity
- Hole ID
- DH_ELP003
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 260
- Grade Unit
- ppm
- Intercept
- 4.9 m
- From
- 188 m
- To
- 192.9 m
- Intercept Depth
- 188 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP003:188-192.9
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 260 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“260”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP006El Pantano West · goldGrade: 0.27Grade Unit: g/tIntercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- DH_ELP006
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 54.8 m
- From
- 0 m
- To
- 54.8 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP006:0-54.8
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 14.8 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: DH_ELP006
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP006El Pantano West · copperGrade: 1025Grade Unit: ppmIntercept: 54.8 mView all detailsHide details
Identity
- Hole ID
- DH_ELP006
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1025
- Grade Unit
- ppm
- Intercept
- 54.8 m
- From
- 0 m
- To
- 54.8 m
- Intercept Depth
- 0 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP006:0-54.8
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1025 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1025”
Context: DH_ELP006
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP006El Pantano West · goldGrade: 1.3Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP006
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1.3
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 21.4 m
- To
- 22 m
- Intercept Depth
- 21.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP006:21.4-22
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 1.3 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.3”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP006El Pantano West · copperGrade: 941Grade Unit: ppmIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP006
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 941
- Grade Unit
- ppm
- Intercept
- 0.6 m
- From
- 21.4 m
- To
- 22 m
- Intercept Depth
- 21.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP006:21.4-22
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 941 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“941”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP006El Pantano West · goldGrade: 0.2Grade Unit: g/tIntercept: 13.7 mView all detailsHide details
Identity
- Hole ID
- DH_ELP006
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 13.7 m
- From
- 105.8 m
- To
- 119.5 m
- Intercept Depth
- 105.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP006:105.8-119.5
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.7 g/t·m is below.
Negative factors
- 0.2 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.2”
Context: DH_ELP006
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP006El Pantano West · copperGrade: 898Grade Unit: ppmIntercept: 13.7 mView all detailsHide details
Identity
- Hole ID
- DH_ELP006
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 898
- Grade Unit
- ppm
- Intercept
- 13.7 m
- From
- 105.8 m
- To
- 119.5 m
- Intercept Depth
- 105.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP006:105.8-119.5
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 898 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“898”
Context: DH_ELP006
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP016El Pantano West · goldGrade: 0.15Grade Unit: g/tIntercept: 6.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP016
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 6.6 m
- From
- 41.4 m
- To
- 48 m
- Intercept Depth
- 41.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP016:41.4-48
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below.
Negative factors
- 0.15 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: DH_ELP016
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP016El Pantano West · copperGrade: 57Grade Unit: ppmIntercept: 6.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP016
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 57
- Grade Unit
- ppm
- Intercept
- 6.6 m
- From
- 41.4 m
- To
- 48 m
- Intercept Depth
- 41.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP016:41.4-48
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 57 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“57”
Context: DH_ELP016
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP017AEl Pantano West · goldGrade: 0.23Grade Unit: g/tIntercept: 3.45 mView all detailsHide details
Identity
- Hole ID
- DH_ELP017A
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 3.45 m
- From
- 91.55 m
- To
- 95 m
- Intercept Depth
- 91.55 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP017A:91.55-95
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.23 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.8 g/t·m is below.
Negative factors
- 0.23 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.23”
Context: DH_ELP017A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP017AEl Pantano West · copperGrade: 78Grade Unit: ppmIntercept: 3.45 mView all detailsHide details
Identity
- Hole ID
- DH_ELP017A
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 78
- Grade Unit
- ppm
- Intercept
- 3.45 m
- From
- 91.55 m
- To
- 95 m
- Intercept Depth
- 91.55 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP017A:91.55-95
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 78 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“78”
Context: DH_ELP017A
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.24Grade Unit: g/tIntercept: 4.4 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.24
- Grade Unit
- g/t
- Intercept
- 4.4 m
- From
- 118.3 m
- To
- 122.7 m
- Intercept Depth
- 118.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:118.3-122.7
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.24 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.1 g/t·m is below.
Negative factors
- 0.24 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.24”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 895Grade Unit: ppmIntercept: 4.4 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 895
- Grade Unit
- ppm
- Intercept
- 4.4 m
- From
- 118.3 m
- To
- 122.7 m
- Intercept Depth
- 118.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:118.3-122.7
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 895 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“895”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.29Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 3.3 m
- From
- 215.7 m
- To
- 219 m
- Intercept Depth
- 215.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:215.7-219
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.29 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.0 g/t·m is below.
Negative factors
- 0.29 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.29”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 225Grade Unit: ppmIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 225
- Grade Unit
- ppm
- Intercept
- 3.3 m
- From
- 215.7 m
- To
- 219 m
- Intercept Depth
- 215.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:215.7-219
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 225 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“225”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.71Grade Unit: g/tIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.71
- Grade Unit
- g/t
- Intercept
- 0.85 m
- From
- 217.8 m
- To
- 218.65 m
- Intercept Depth
- 217.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:217.8-218.65
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.71 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.71”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 212Grade Unit: ppmIntercept: 0.85 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 212
- Grade Unit
- ppm
- Intercept
- 0.85 m
- From
- 217.8 m
- To
- 218.65 m
- Intercept Depth
- 217.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:217.8-218.65
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 212 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“212”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.27Grade Unit: g/tIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.27
- Grade Unit
- g/t
- Intercept
- 2.5 m
- From
- 247 m
- To
- 249.5 m
- Intercept Depth
- 247 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:247-249.5
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.27 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 0.27 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.27”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 1500Grade Unit: ppmIntercept: 2.5 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1500
- Grade Unit
- ppm
- Intercept
- 2.5 m
- From
- 247 m
- To
- 249.5 m
- Intercept Depth
- 247 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:247-249.5
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1500 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1500”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.66Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.66
- Grade Unit
- g/t
- Intercept
- 0.6 m
- From
- 248 m
- To
- 248.6 m
- Intercept Depth
- 248 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:248-248.6
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.66 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.4 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.66”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 2848Grade Unit: ppmIntercept: 0.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 2848
- Grade Unit
- ppm
- Intercept
- 0.6 m
- From
- 248 m
- To
- 248.6 m
- Intercept Depth
- 248 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:248-248.6
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 2848 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“2848”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.18Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 259 m
- To
- 263 m
- Intercept Depth
- 259 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:259-263
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below.
Negative factors
- 0.18 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.18”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 1126Grade Unit: ppmIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1126
- Grade Unit
- ppm
- Intercept
- 4 m
- From
- 259 m
- To
- 263 m
- Intercept Depth
- 259 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:259-263
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1126 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1126”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.15Grade Unit: g/tIntercept: 15.13 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 15.13 m
- From
- 278.4 m
- To
- 293.53 m
- Intercept Depth
- 278.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:278.4-293.53
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.3 g/t·m is below.
Negative factors
- 0.15 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 959Grade Unit: ppmIntercept: 15.13 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 959
- Grade Unit
- ppm
- Intercept
- 15.13 m
- From
- 278.4 m
- To
- 293.53 m
- Intercept Depth
- 278.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:278.4-293.53
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 959 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“959”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.59Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.59
- Grade Unit
- g/t
- Intercept
- 1.1 m
- From
- 305.7 m
- To
- 306.8 m
- Intercept Depth
- 305.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:305.7-306.8
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.59 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.59”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 691Grade Unit: ppmIntercept: 1.1 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 691
- Grade Unit
- ppm
- Intercept
- 1.1 m
- From
- 305.7 m
- To
- 306.8 m
- Intercept Depth
- 305.7 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:305.7-306.8
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 691 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“691”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 1.13Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1.13
- Grade Unit
- g/t
- Intercept
- 0.4 m
- From
- 306.4 m
- To
- 306.8 m
- Intercept Depth
- 306.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:306.4-306.8
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 1.13 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.13”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 742Grade Unit: ppmIntercept: 0.4 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 742
- Grade Unit
- ppm
- Intercept
- 0.4 m
- From
- 306.4 m
- To
- 306.8 m
- Intercept Depth
- 306.4 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:306.4-306.8
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 742 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“742”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.2Grade Unit: g/tIntercept: 27.12 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.2
- Grade Unit
- g/t
- Intercept
- 27.12 m
- From
- 316 m
- To
- 343.12 m
- Intercept Depth
- 316 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:316-343.12
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.2 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 5.4 g/t·m is below.
Negative factors
- 0.2 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.2”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 917Grade Unit: ppmIntercept: 27.12 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 917
- Grade Unit
- ppm
- Intercept
- 27.12 m
- From
- 316 m
- To
- 343.12 m
- Intercept Depth
- 316 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:316-343.12
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 917 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“917”
Context: DH_ELP018
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.39Grade Unit: g/tIntercept: 2.18 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.39
- Grade Unit
- g/t
- Intercept
- 2.18 m
- From
- 325.82 m
- To
- 328 m
- Intercept Depth
- 325.82 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:325.82-328
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.39 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.9 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.39”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 1263Grade Unit: ppmIntercept: 2.18 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1263
- Grade Unit
- ppm
- Intercept
- 2.18 m
- From
- 325.82 m
- To
- 328 m
- Intercept Depth
- 325.82 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:325.82-328
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1263 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1263”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · goldGrade: 0.61Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.61
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 339.9 m
- To
- 340.2 m
- Intercept Depth
- 339.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:339.9-340.2
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.61 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.61”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP018El Pantano West · copperGrade: 3558Grade Unit: ppmIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- DH_ELP018
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 3558
- Grade Unit
- ppm
- Intercept
- 0.3 m
- From
- 339.9 m
- To
- 340.2 m
- Intercept Depth
- 339.9 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP018:339.9-340.2
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 3558 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“3558”
Context: including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP020El Pantano West · goldGrade: 0.21Grade Unit: g/tIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- DH_ELP020
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 1.45 m
- From
- 107 m
- To
- 108.45 m
- Intercept Depth
- 107 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP020:107-108.45
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.21 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: DH_ELP020
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP020El Pantano West · copperGrade: 1009Grade Unit: ppmIntercept: 1.45 mView all detailsHide details
Identity
- Hole ID
- DH_ELP020
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1009
- Grade Unit
- ppm
- Intercept
- 1.45 m
- From
- 107 m
- To
- 108.45 m
- Intercept Depth
- 107 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP020:107-108.45
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1009 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1009”
Context: DH_ELP020
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP021El Pantano West · goldGrade: 0.4Grade Unit: g/tIntercept: 1.65 mView all detailsHide details
Identity
- Hole ID
- DH_ELP021
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.4
- Grade Unit
- g/t
- Intercept
- 1.65 m
- From
- 134 m
- To
- 135.65 m
- Intercept Depth
- 134 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP021:134-135.65
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.4 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.7 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.4”
Context: DH_ELP021
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP021El Pantano West · copperGrade: 1745Grade Unit: ppmIntercept: 1.65 mView all detailsHide details
Identity
- Hole ID
- DH_ELP021
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 1745
- Grade Unit
- ppm
- Intercept
- 1.65 m
- From
- 134 m
- To
- 135.65 m
- Intercept Depth
- 134 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP021:134-135.65
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 1745 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“1745”
Context: DH_ELP021
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP022El Pantano West · goldGrade: 0.21Grade Unit: g/tIntercept: 2.25 mView all detailsHide details
Identity
- Hole ID
- DH_ELP022
- Project
- El Pantano West
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 2.25 m
- From
- 179.75 m
- To
- 182 m
- Intercept Depth
- 179.75 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP022:179.75-182
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below.
Negative factors
- 0.21 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: DH_ELP022
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP022El Pantano West · copperGrade: 427Grade Unit: ppmIntercept: 2.25 mView all detailsHide details
Identity
- Hole ID
- DH_ELP022
- Project
- El Pantano West
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 427
- Grade Unit
- ppm
- Intercept
- 2.25 m
- From
- 179.75 m
- To
- 182 m
- Intercept Depth
- 179.75 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP022:179.75-182
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 427 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“427”
Context: DH_ELP022
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP023interpreted as representing relatively deeper or more eroded levels of the hydrothermal · goldGrade: 0.14Grade Unit: g/tIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- DH_ELP023
- Project
- interpreted as representing relatively deeper or more eroded levels of the hydrothermal
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.14
- Grade Unit
- g/t
- Intercept
- 27 m
- From
- 100 m
- To
- 127 m
- Intercept Depth
- 100 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP023:100-127
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.14 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.8 g/t·m is below.
Negative factors
- 0.14 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.14”
Context: DH_ELP023
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP023interpreted as representing relatively deeper or more eroded levels of the hydrothermal · copperGrade: 734Grade Unit: ppmIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- DH_ELP023
- Project
- interpreted as representing relatively deeper or more eroded levels of the hydrothermal
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 734
- Grade Unit
- ppm
- Intercept
- 27 m
- From
- 100 m
- To
- 127 m
- Intercept Depth
- 100 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP023:100-127
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 734 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“734”
Context: DH_ELP023
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP023interpreted as representing relatively deeper or more eroded levels of the hydrothermal · goldGrade: 0.13Grade Unit: g/tIntercept: 23.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP023
- Project
- interpreted as representing relatively deeper or more eroded levels of the hydrothermal
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.13
- Grade Unit
- g/t
- Intercept
- 23.6 m
- From
- 201.5 m
- To
- 225.1 m
- Intercept Depth
- 201.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP023:201.5-225.1
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 3.1 g/t·m is below.
Negative factors
- 0.13 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: DH_ELP023
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP023interpreted as representing relatively deeper or more eroded levels of the hydrothermal · copperGrade: 545Grade Unit: ppmIntercept: 23.6 mView all detailsHide details
Identity
- Hole ID
- DH_ELP023
- Project
- interpreted as representing relatively deeper or more eroded levels of the hydrothermal
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 545
- Grade Unit
- ppm
- Intercept
- 23.6 m
- From
- 201.5 m
- To
- 225.1 m
- Intercept Depth
- 201.5 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP023:201.5-225.1
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 545 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“545”
Context: DH_ELP023
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP023interpreted as representing relatively deeper or more eroded levels of the hydrothermal · goldGrade: 0.12Grade Unit: g/tIntercept: 20.7 mView all detailsHide details
Identity
- Hole ID
- DH_ELP023
- Project
- interpreted as representing relatively deeper or more eroded levels of the hydrothermal
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 0.12
- Grade Unit
- g/t
- Intercept
- 20.7 m
- From
- 244.3 m
- To
- 265 m
- Intercept Depth
- 244.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP023:244.3-265
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table. 0.12 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.5 g/t·m is below.
Negative factors
- 0.12 g/t gold is below the weak threshold (0.3 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.12”
Context: DH_ELP023
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
DH_ELP023interpreted as representing relatively deeper or more eroded levels of the hydrothermal · copperGrade: 700Grade Unit: ppmIntercept: 20.7 mView all detailsHide details
Identity
- Hole ID
- DH_ELP023
- Project
- interpreted as representing relatively deeper or more eroded levels of the hydrothermal
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- OMI
Geometry
- Grade
- 700
- Grade Unit
- ppm
- Intercept
- 20.7 m
- From
- 244.3 m
- To
- 265 m
- Intercept Depth
- 244.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- DH_ELP023:244.3-265
- Mining Method
- unknown
Location
- CRS
- WGS84 UTM Zone 18
QA/QC
- Laboratory
- Alex Stewart Laboratories
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-22T00:00:00.000Z
Reasoning: Expanded from assay table: 700 ppm copper, reported in a unit the rubric does not cover (%).
Negative factors
- Grade unit ppm does not match the copper rubric unit %; not scored.
Evidence · table
“700”
Context: DH_ELP023
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.