ORVANA PROVIDES TAGUAS DRILLING UPDATE: FULL ASSAY RESULTS FROM 2026 DRILLING CAMPAIGN; PROVIDES EL VALLE-BOINÁS BROWNFIELD DRILLING UPDATE

Original announcement by tmx on

Company
Orvana Minerals Corp.
Ticker
ORV
Exchange
TSX
Region
San Juan, Argentina
Primary commodity
Gold
Secondary commodities
Copper, Silver
Document categories
Drill results
Extracted
2026-09-18 14:52:20 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Orvana Minerals Corp. announced full assay results from its 2026 deep drilling campaign at the Taguas Project in San Juan, Argentina, highlighted by high-grade gold and copper intercepts. The results, including 1.25 metres grading 9.19 g/t gold and 5.55% copper, reinforce the interpretation of a high-sulfidation epithermal system potentially linked to a deeper porphyry source. The company also provided an update on its brownfield and infill drilling programs at the El Valle–Boinás Mine in Spain, with assay results pending.

Reasoning: The drilling campaign at the Taguas Project returned several high-grade gold and copper intercepts, reinforcing the interpretation of a deeper porphyry system and demonstrating vertical continuity. The results are supported by detailed geological studies and robust QA/QC, though true widths remain unknown and the presence of arsenic is noted.

Positive factors

  • High-grade gold and copper intercepts
  • Geological interpretation supports deeper porphyry potential
  • Robust QA/QC procedures disclosed
  • Vertical continuity of mineralization demonstrated

Negative factors

  • True widths of intercepts are not yet known
  • Presence of arsenic-bearing minerals (enargite) noted for copper
  • No cut-off grade applied to reported intervals

Facts used in scoring: 69

Extracted facts

Stored fact records: 69. Some facts used in scoring do not have a stored record.

Drill Results (69)

TADD-278Taguas · goldGrade: 32.34Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
32.34
Grade Unit
g/t
Intercept
2 m
From
490 m
To
492 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:490-492
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows an exceptional gold grade (32.34 g/t), indicating strong mineralization at depth, contributing significantly to the project's potential, despite its short length and unknown true width.

Positive factors

  • Exceptional gold grade
  • Confirms mineralization at depth

Negative factors

  • Short intercept length
  • True width unknown

Evidence · table

“32.34”

Context: 2.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Gold grade of 32.34 g/t is well above the exceptional threshold for porphyry gold (1 g/t).

Evidence · table

“32.34”

Context: 2.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 4.5Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
4.5
Grade Unit
g/t
Intercept
2 m
From
490 m
To
492 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:490-492
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade and short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“4.50”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.06Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.06
Grade Unit
%
Intercept
2 m
From
490 m
To
492 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:490-492
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This copper intercept is very low grade and short, contributing minimally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low copper grade
  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.06*”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.32Grade Unit: g/tIntercept: 16.8 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.32
Grade Unit
g/t
Intercept
16.8 m
From
536 m
To
552.8 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:536-552.8
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a moderate length, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low gold grade
  • True width unknown

Evidence · table

“0.32”

Context: 16.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 4.2Grade Unit: g/tIntercept: 16.8 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
4.2
Grade Unit
g/t
Intercept
16.8 m
From
536 m
To
552.8 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:536-552.8
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • True width unknown

Evidence · table

“4.20”

Context: 16.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.81Grade Unit: %Intercept: 16.8 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.81
Grade Unit
%
Intercept
16.8 m
From
536 m
To
552.8 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:536-552.8
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a moderate copper grade over a good length for a porphyry deposit, confirming mineralization, but the unknown true width and presence of arsenic are negative factors.

Positive factors

  • Moderate copper grade for porphyry
  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.81*”

Context: 16.80

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 1.34Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.34
Grade Unit
g/t
Intercept
1 m
From
536 m
To
537 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:536-537
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a strong gold grade, indicating a high-grade sub-interval within a broader zone, but its very short length and unknown true width limit its individual significance.

Positive factors

  • Strong gold grade for porphyry
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown

Evidence · table

“1.34”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 20Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
20
Grade Unit
g/t
Intercept
1 m
From
536 m
To
537 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:536-537
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • Very short intercept length
  • True width unknown

Evidence · table

“20.00”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 5.39Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
5.39
Grade Unit
%
Intercept
1 m
From
536 m
To
537 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:536-537
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.

Positive factors

  • Exceptional copper grade for porphyry
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“5.39*”

Context: 1.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Copper grade of 5.39% is well above the exceptional threshold for porphyry copper (0.8%).

Evidence · table

“5.39*”

Context: 1.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 1.49Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.49
Grade Unit
g/t
Intercept
1.3 m
From
551.5 m
To
552.8 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:551.5-552.8
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a strong gold grade, indicating a high-grade sub-interval within a broader zone, but its very short length and unknown true width limit its individual significance.

Positive factors

  • Strong gold grade for porphyry
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown

Evidence · table

“1.49”

Context: 1.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 9Grade Unit: g/tIntercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
9
Grade Unit
g/t
Intercept
1.3 m
From
551.5 m
To
552.8 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:551.5-552.8
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • Very short intercept length
  • True width unknown

Evidence · table

“9.00”

Context: 1.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 2.44Grade Unit: %Intercept: 1.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
2.44
Grade Unit
%
Intercept
1.3 m
From
551.5 m
To
552.8 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:551.5-552.8
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.

Positive factors

  • Exceptional copper grade for porphyry
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“2.44*”

Context: 1.30

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Copper grade of 2.44% is well above the exceptional threshold for porphyry copper (0.8%).

Evidence · table

“2.44*”

Context: 1.30

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.86Grade Unit: g/tIntercept: 37 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.86
Grade Unit
g/t
Intercept
37 m
From
638 m
To
675 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:638-675
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a good length, indicating significant mineralization at depth, but the unknown true width is a negative factor.

Positive factors

  • Moderate gold grade for porphyry
  • Good intercept length
  • Confirms mineralization at depth

Negative factors

  • True width unknown

Evidence · table

“0.86”

Context: 37.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 6.09Grade Unit: g/tIntercept: 37 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
6.09
Grade Unit
g/t
Intercept
37 m
From
638 m
To
675 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:638-675
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade over a good length, confirming mineralization but not indicating high economic potential.

Positive factors

  • Good intercept length
  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • True width unknown

Evidence · table

“6.09”

Context: 37.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.69Grade Unit: %Intercept: 37 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.69
Grade Unit
%
Intercept
37 m
From
638 m
To
675 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:638-675
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a moderate copper grade over a good length for a porphyry deposit, confirming mineralization, but the unknown true width and presence of arsenic are negative factors.

Positive factors

  • Moderate copper grade for porphyry
  • Good intercept length
  • Confirms mineralization at depth

Negative factors

  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.69*”

Context: 37.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 5.62Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
5.62
Grade Unit
g/t
Intercept
3 m
From
672 m
To
675 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:672-675
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows an exceptional gold grade, indicating a high-grade sub-interval within a broader zone, but its limited length and unknown true width are noted.

Positive factors

  • Exceptional gold grade for porphyry
  • Confirms high-grade sub-interval

Negative factors

  • Short intercept length
  • True width unknown

Evidence · table

“5.62”

Context: 3.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Gold grade of 5.62 g/t is well above the exceptional threshold for porphyry gold (1 g/t).

Evidence · table

“5.62”

Context: 3.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 10.2Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
10.2
Grade Unit
g/t
Intercept
3 m
From
672 m
To
675 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:672-675
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade and short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“10.20”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.29Grade Unit: %Intercept: 3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.29
Grade Unit
%
Intercept
3 m
From
672 m
To
675 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:672-675
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.29*”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.25Grade Unit: g/tIntercept: 205 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.25
Grade Unit
g/t
Intercept
205 m
From
715 m
To
920 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:715-920
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very long intercept shows broad, low-grade gold mineralization at depth, which is positive for bulk tonnage potential, but the low grade and unknown true width are noted.

Positive factors

  • Very long intercept length
  • Confirms broad mineralization at depth

Negative factors

  • Low gold grade
  • True width unknown

Evidence · table

“0.25”

Context: 205.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 1.82Grade Unit: g/tIntercept: 205 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.82
Grade Unit
g/t
Intercept
205 m
From
715 m
To
920 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:715-920
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very long intercept shows broad, very low-grade silver mineralization at depth, contributing marginally to the overall prospectivity.

Positive factors

  • Very long intercept length
  • Confirms broad mineralization at depth

Negative factors

  • Very low silver grade
  • True width unknown

Evidence · table

“1.82”

Context: 205.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.12Grade Unit: %Intercept: 205 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.12
Grade Unit
%
Intercept
205 m
From
715 m
To
920 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:715-920
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very long intercept shows broad, low-grade copper mineralization at depth, which is positive for bulk tonnage potential, but the low grade and unknown true width are noted.

Positive factors

  • Very long intercept length
  • Confirms broad mineralization at depth

Negative factors

  • Low copper grade
  • True width unknown

Evidence · table

“0.12”

Context: 205.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.43Grade Unit: g/tIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.43
Grade Unit
g/t
Intercept
16 m
From
812 m
To
828 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:812-828
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a moderate length, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low gold grade
  • True width unknown

Evidence · table

“0.43”

Context: 16.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 3.37Grade Unit: g/tIntercept: 16 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
3.37
Grade Unit
g/t
Intercept
16 m
From
812 m
To
828 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:812-828
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • True width unknown

Evidence · table

“3.37”

Context: 16.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.07Grade Unit: %Intercept: 16 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.07
Grade Unit
%
Intercept
16 m
From
812 m
To
828 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:812-828
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows very low copper grade over a moderate length, contributing minimally to the overall prospectivity.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Very low copper grade
  • True width unknown

Evidence · table

“0.07”

Context: 16.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.61Grade Unit: g/tIntercept: 15 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.61
Grade Unit
g/t
Intercept
15 m
From
848 m
To
863 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:848-863
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a moderate gold grade over a moderate length, confirming mineralization at depth, but the unknown true width is a negative factor.

Positive factors

  • Moderate gold grade for porphyry
  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • True width unknown

Evidence · table

“0.61”

Context: 15.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 4.06Grade Unit: g/tIntercept: 15 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
4.06
Grade Unit
g/t
Intercept
15 m
From
848 m
To
863 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:848-863
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • True width unknown

Evidence · table

“4.06”

Context: 15.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.21Grade Unit: %Intercept: 15 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.21
Grade Unit
%
Intercept
15 m
From
848 m
To
863 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:848-863
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low copper grade over a moderate length, confirming mineralization but not indicating high economic potential.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • True width unknown

Evidence · table

“0.21”

Context: 15.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.3Grade Unit: g/tIntercept: 7.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.3
Grade Unit
g/t
Intercept
7.3 m
From
1007.7 m
To
1015 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1007.7-1015
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low gold grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.30”

Context: 7.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 8.2Grade Unit: g/tIntercept: 7.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
8.2
Grade Unit
g/t
Intercept
7.3 m
From
1007.7 m
To
1015 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1007.7-1015
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade over a moderate length at significant depth, contributing marginally to the overall prospectivity.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low silver grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“8.20”

Context: 7.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.28Grade Unit: %Intercept: 7.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.28
Grade Unit
%
Intercept
7.3 m
From
1007.7 m
To
1015 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1007.7-1015
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low copper grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low copper grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.28”

Context: 7.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.23Grade Unit: g/tIntercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.23
Grade Unit
g/t
Intercept
11.3 m
From
1097.7 m
To
1109 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1097.7-1109
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low gold grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.23”

Context: 11.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 1.71Grade Unit: g/tIntercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.71
Grade Unit
g/t
Intercept
11.3 m
From
1097.7 m
To
1109 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1097.7-1109
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is very low grade over a moderate length at significant depth, contributing marginally to the overall prospectivity.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Very low silver grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“1.71”

Context: 11.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.26Grade Unit: %Intercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.26
Grade Unit
%
Intercept
11.3 m
From
1097.7 m
To
1109 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1097.7-1109
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low copper grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low copper grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.26”

Context: 11.30

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · goldGrade: 0.29Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.29
Grade Unit
g/t
Intercept
6 m
From
1121 m
To
1127 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1121-1127
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low gold grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.29”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · silverGrade: 1.48Grade Unit: g/tIntercept: 6 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.48
Grade Unit
g/t
Intercept
6 m
From
1121 m
To
1127 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1121-1127
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is very low grade over a moderate length at significant depth, contributing marginally to the overall prospectivity.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Very low silver grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“1.48”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-278Taguas · copperGrade: 0.19Grade Unit: %Intercept: 6 mView all details
Link to this fact

Identity

Hole ID
TADD-278
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.19
Grade Unit
%
Intercept
6 m
From
1121 m
To
1127 m
Hole Depth
1331.7 m
Intercept Depth
490 m

Classification

Deposit Type
porphyry
Program
exploration
Sample Type
drill
Group ID
TADD-278:1121-1127
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low copper grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential.

Positive factors

  • Confirms mineralization at significant depth

Negative factors

  • Low copper grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.19”

Context: 6.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.15Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.15
Grade Unit
g/t
Intercept
3 m
From
361 m
To
364 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:361-364
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low gold grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.15”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 2.36Grade Unit: g/tIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
2.36
Grade Unit
g/t
Intercept
3 m
From
361 m
To
364 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:361-364
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“2.36”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.41Grade Unit: %Intercept: 3 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.41
Grade Unit
%
Intercept
3 m
From
361 m
To
364 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:361-364
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.41*”

Context: 3.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.18Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
7 m
From
372 m
To
379 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:372-379
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low gold grade over a moderate length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low gold grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“0.18”

Context: 7.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 2.92Grade Unit: g/tIntercept: 7 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
2.92
Grade Unit
g/t
Intercept
7 m
From
372 m
To
379 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:372-379
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low silver grade over a moderate length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • Moderate intercept length
  • True width unknown

Evidence · table

“2.92”

Context: 7.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.43Grade Unit: %Intercept: 7 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.43
Grade Unit
%
Intercept
7 m
From
372 m
To
379 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:372-379
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low copper grade over a moderate length, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • Moderate intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.43*”

Context: 7.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 2.44Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
2.44
Grade Unit
g/t
Intercept
5 m
From
398 m
To
403 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:398-403
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade over a moderate length, indicating significant mineralization at depth, but the unknown true width is a negative factor.

Positive factors

  • Strong gold grade for epithermal
  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • True width unknown

Evidence · table

“2.44”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 9.48Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
9.48
Grade Unit
g/t
Intercept
5 m
From
398 m
To
403 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:398-403
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • True width unknown

Evidence · table

“9.48”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 1.69Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.69
Grade Unit
%
Intercept
5 m
From
398 m
To
403 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:398-403
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a strong copper grade over a moderate length, indicating significant mineralization at depth, but the unknown true width and presence of arsenic are negative factors.

Positive factors

  • Strong copper grade for epithermal
  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“1.69*”

Context: 5.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 9.19Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
9.19
Grade Unit
g/t
Intercept
1.25 m
From
398 m
To
399.25 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:398-399.25
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very short intercept shows an exceptional gold grade (9.19 g/t), indicating a high-grade sub-interval within a broader zone, but its limited length and unknown true width are noted.

Positive factors

  • Exceptional gold grade
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown

Evidence · table

“9.19”

Context: 1.25

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Gold grade of 9.19 g/t is well above the exceptional threshold for epithermal gold (5 g/t).

Evidence · table

“9.19”

Context: 1.25

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 28.1Grade Unit: g/tIntercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
28.1
Grade Unit
g/t
Intercept
1.25 m
From
398 m
To
399.25 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:398-399.25
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • Very short intercept length
  • True width unknown

Evidence · table

“28.10”

Context: 1.25

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 5.55Grade Unit: %Intercept: 1.25 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
5.55
Grade Unit
%
Intercept
1.25 m
From
398 m
To
399.25 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:398-399.25
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.

Positive factors

  • Exceptional copper grade for epithermal
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“5.55*”

Context: 1.25

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Copper grade of 5.55% is well above the exceptional threshold for epithermal copper (2.5%).

Evidence · table

“5.55*”

Context: 1.25

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.19Grade Unit: g/tIntercept: 17 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
17 m
From
427 m
To
444 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:427-444
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a moderate length, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low gold grade
  • True width unknown

Evidence · table

“0.19”

Context: 17.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 2.04Grade Unit: g/tIntercept: 17 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
2.04
Grade Unit
g/t
Intercept
17 m
From
427 m
To
444 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:427-444
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is very low grade over a moderate length, contributing minimally to the overall prospectivity.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • True width unknown

Evidence · table

“2.04”

Context: 17.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.28Grade Unit: %Intercept: 17 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.28
Grade Unit
%
Intercept
17 m
From
427 m
To
444 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:427-444
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low copper grade over a moderate length, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Moderate intercept length
  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.28*”

Context: 17.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 1.12Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.12
Grade Unit
g/t
Intercept
1 m
From
439 m
To
440 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:439-440
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very short intercept shows a moderate gold grade, indicating a high-grade sub-interval within a broader zone, but its limited length and unknown true width are noted.

Positive factors

  • Moderate gold grade for epithermal
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown

Evidence · table

“1.12”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 20.6Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
20.6
Grade Unit
g/t
Intercept
1 m
From
439 m
To
440 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:439-440
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low silver grade
  • Very short intercept length
  • True width unknown

Evidence · table

“20.60”

Context: 1.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 3.49Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
3.49
Grade Unit
%
Intercept
1 m
From
439 m
To
440 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:439-440
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.

Positive factors

  • Exceptional copper grade for epithermal
  • Confirms high-grade sub-interval

Negative factors

  • Very short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“3.49*”

Context: 1.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Copper grade of 3.49% is well above the exceptional threshold for epithermal copper (2.5%).

Evidence · table

“3.49*”

Context: 1.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.25Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.25
Grade Unit
g/t
Intercept
2 m
From
470 m
To
472 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:470-472
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low gold grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.25”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 3.2Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
3.2
Grade Unit
g/t
Intercept
2 m
From
470 m
To
472 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:470-472
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“3.20”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.36Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.36
Grade Unit
%
Intercept
2 m
From
470 m
To
472 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:470-472
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.36*”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.57Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.57
Grade Unit
g/t
Intercept
2 m
From
648 m
To
650 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:648-650
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a short length, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low gold grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.57”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 1.1Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.1
Grade Unit
g/t
Intercept
2 m
From
648 m
To
650 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:648-650
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“1.10”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.17Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.17
Grade Unit
%
Intercept
2 m
From
648 m
To
650 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:648-650
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a very low copper grade, contributing minimally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low copper grade
  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.17*”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.64Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.64
Grade Unit
g/t
Intercept
2 m
From
686 m
To
688 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:686-688
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a low gold grade over a short length, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low gold grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.64”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 0.25Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.25
Grade Unit
g/t
Intercept
2 m
From
686 m
To
688 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:686-688
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.25”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.02Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.02
Grade Unit
%
Intercept
2 m
From
686 m
To
688 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:686-688
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows an extremely low copper grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Extremely low copper grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.02”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · goldGrade: 0.18Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
2 m
From
756 m
To
758 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:756-758
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low gold grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.18”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 38.7Grade Unit: g/tIntercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
38.7
Grade Unit
g/t
Intercept
2 m
From
756 m
To
758 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:756-758
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a short length, confirming mineralization but not indicating high economic potential on its own.

Positive factors

  • Moderate silver grade for epithermal
  • Confirms mineralization at depth

Negative factors

  • Short intercept length
  • True width unknown

Evidence · table

“38.70”

Context: 2.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 7.19Grade Unit: %Intercept: 2 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
7.19
Grade Unit
%
Intercept
2 m
From
756 m
To
758 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:756-758
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows an exceptional copper grade (7.19%), indicating strong mineralization at depth, but its limited length and presence of arsenic are noted.

Positive factors

  • Exceptional copper grade for epithermal
  • Confirms mineralization at depth

Negative factors

  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“7.19*”

Context: 2.00

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: Copper grade of 7.19% is well above the exceptional threshold for epithermal copper (2.5%).

Evidence · table

“7.19*”

Context: 2.00

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: deleterious_flag is true

TADD-279Taguas · goldGrade: 0.16Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
gold
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
4 m
From
836 m
To
840 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:836-840
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low gold grade
  • Short intercept length
  • True width unknown

Evidence · table

“0.16”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · silverGrade: 1.9Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
silver
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
4 m
From
836 m
To
840 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:836-840
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Very low silver grade
  • Short intercept length
  • True width unknown

Evidence · table

“1.90”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

TADD-279Taguas · copperGrade: 0.36Grade Unit: %Intercept: 4 mView all details
Link to this fact

Identity

Hole ID
TADD-279
Project
Taguas
Commodity
copper
Region
argentina
Reported Region
argentina
Ticker
ORV

Geometry

Grade
0.36
Grade Unit
%
Intercept
4 m
From
836 m
To
840 m
Hole Depth
842 m
Intercept Depth
361 m

Classification

Deposit Type
epithermal
Program
exploration
Sample Type
drill
Group ID
TADD-279:836-840
Mining Method
unknown

QA/QC

Laboratory
Alex Stewart International Argentina SA Laboratory in Mendoza
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Deleterious

Deleterious Flag
Yes
Deleterious Elements
arsenic

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-02T00:00:00.000Z

Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.

Positive factors

  • Confirms mineralization at depth

Negative factors

  • Low copper grade
  • Short intercept length
  • True width unknown
  • Presence of arsenic-bearing enargite

Evidence · table

“0.36*”

Context: 4.00

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Intercept reported as downhole length with no true width stated.

Evidence · text

“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.

Evidence · text

“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”

Deleterious Elements Presentnegative

A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.

Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.

Evidence · text

“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.