ORVANA PROVIDES TAGUAS DRILLING UPDATE: FULL ASSAY RESULTS FROM 2026 DRILLING CAMPAIGN; PROVIDES EL VALLE-BOINÁS BROWNFIELD DRILLING UPDATE
Original announcement by tmx on
- Company
- Orvana Minerals Corp.
- Ticker
- ORV
- Exchange
- TSX
- Region
- San Juan, Argentina
- Primary commodity
- Gold
- Secondary commodities
- Copper, Silver
- Document categories
- Drill results
- Extracted
- 2026-09-18 14:52:20 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Orvana Minerals Corp. announced full assay results from its 2026 deep drilling campaign at the Taguas Project in San Juan, Argentina, highlighted by high-grade gold and copper intercepts. The results, including 1.25 metres grading 9.19 g/t gold and 5.55% copper, reinforce the interpretation of a high-sulfidation epithermal system potentially linked to a deeper porphyry source. The company also provided an update on its brownfield and infill drilling programs at the El Valle–Boinás Mine in Spain, with assay results pending.
Reasoning: The drilling campaign at the Taguas Project returned several high-grade gold and copper intercepts, reinforcing the interpretation of a deeper porphyry system and demonstrating vertical continuity. The results are supported by detailed geological studies and robust QA/QC, though true widths remain unknown and the presence of arsenic is noted.
Positive factors
- High-grade gold and copper intercepts
- Geological interpretation supports deeper porphyry potential
- Robust QA/QC procedures disclosed
- Vertical continuity of mineralization demonstrated
Negative factors
- True widths of intercepts are not yet known
- Presence of arsenic-bearing minerals (enargite) noted for copper
- No cut-off grade applied to reported intervals
Facts used in scoring: 69
Extracted facts
Stored fact records: 69. Some facts used in scoring do not have a stored record.
Drill Results (69)
TADD-278Taguas · goldGrade: 32.34Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 32.34
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 490 m
- To
- 492 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:490-492
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows an exceptional gold grade (32.34 g/t), indicating strong mineralization at depth, contributing significantly to the project's potential, despite its short length and unknown true width.
Positive factors
- Exceptional gold grade
- Confirms mineralization at depth
Negative factors
- Short intercept length
- True width unknown
Evidence · table
“32.34”
Context: 2.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Gold grade of 32.34 g/t is well above the exceptional threshold for porphyry gold (1 g/t).
Evidence · table
“32.34”
Context: 2.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 4.5Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 4.5
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 490 m
- To
- 492 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:490-492
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade and short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low silver grade
- Short intercept length
- True width unknown
Evidence · table
“4.50”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.06Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 2 m
- From
- 490 m
- To
- 492 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:490-492
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This copper intercept is very low grade and short, contributing minimally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low copper grade
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.06*”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.32Grade Unit: g/tIntercept: 16.8 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.32
- Grade Unit
- g/t
- Intercept
- 16.8 m
- From
- 536 m
- To
- 552.8 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:536-552.8
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a moderate length, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low gold grade
- True width unknown
Evidence · table
“0.32”
Context: 16.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 4.2Grade Unit: g/tIntercept: 16.8 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 4.2
- Grade Unit
- g/t
- Intercept
- 16.8 m
- From
- 536 m
- To
- 552.8 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:536-552.8
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low silver grade
- True width unknown
Evidence · table
“4.20”
Context: 16.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.81Grade Unit: %Intercept: 16.8 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.81
- Grade Unit
- %
- Intercept
- 16.8 m
- From
- 536 m
- To
- 552.8 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:536-552.8
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade over a good length for a porphyry deposit, confirming mineralization, but the unknown true width and presence of arsenic are negative factors.
Positive factors
- Moderate copper grade for porphyry
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.81*”
Context: 16.80
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 1.34Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.34
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 536 m
- To
- 537 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:536-537
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a strong gold grade, indicating a high-grade sub-interval within a broader zone, but its very short length and unknown true width limit its individual significance.
Positive factors
- Strong gold grade for porphyry
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
Evidence · table
“1.34”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 20Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 20
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 536 m
- To
- 537 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:536-537
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low silver grade
- Very short intercept length
- True width unknown
Evidence · table
“20.00”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 5.39Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 5.39
- Grade Unit
- %
- Intercept
- 1 m
- From
- 536 m
- To
- 537 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:536-537
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.
Positive factors
- Exceptional copper grade for porphyry
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“5.39*”
Context: 1.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Copper grade of 5.39% is well above the exceptional threshold for porphyry copper (0.8%).
Evidence · table
“5.39*”
Context: 1.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 1.49Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.49
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 551.5 m
- To
- 552.8 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:551.5-552.8
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a strong gold grade, indicating a high-grade sub-interval within a broader zone, but its very short length and unknown true width limit its individual significance.
Positive factors
- Strong gold grade for porphyry
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
Evidence · table
“1.49”
Context: 1.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 9Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 9
- Grade Unit
- g/t
- Intercept
- 1.3 m
- From
- 551.5 m
- To
- 552.8 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:551.5-552.8
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low silver grade
- Very short intercept length
- True width unknown
Evidence · table
“9.00”
Context: 1.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 2.44Grade Unit: %Intercept: 1.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 2.44
- Grade Unit
- %
- Intercept
- 1.3 m
- From
- 551.5 m
- To
- 552.8 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:551.5-552.8
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.
Positive factors
- Exceptional copper grade for porphyry
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“2.44*”
Context: 1.30
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Copper grade of 2.44% is well above the exceptional threshold for porphyry copper (0.8%).
Evidence · table
“2.44*”
Context: 1.30
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.86Grade Unit: g/tIntercept: 37 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.86
- Grade Unit
- g/t
- Intercept
- 37 m
- From
- 638 m
- To
- 675 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:638-675
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a good length, indicating significant mineralization at depth, but the unknown true width is a negative factor.
Positive factors
- Moderate gold grade for porphyry
- Good intercept length
- Confirms mineralization at depth
Negative factors
- True width unknown
Evidence · table
“0.86”
Context: 37.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 6.09Grade Unit: g/tIntercept: 37 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 6.09
- Grade Unit
- g/t
- Intercept
- 37 m
- From
- 638 m
- To
- 675 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:638-675
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade over a good length, confirming mineralization but not indicating high economic potential.
Positive factors
- Good intercept length
- Confirms mineralization at depth
Negative factors
- Low silver grade
- True width unknown
Evidence · table
“6.09”
Context: 37.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.69Grade Unit: %Intercept: 37 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.69
- Grade Unit
- %
- Intercept
- 37 m
- From
- 638 m
- To
- 675 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:638-675
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a moderate copper grade over a good length for a porphyry deposit, confirming mineralization, but the unknown true width and presence of arsenic are negative factors.
Positive factors
- Moderate copper grade for porphyry
- Good intercept length
- Confirms mineralization at depth
Negative factors
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.69*”
Context: 37.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 5.62Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 5.62
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 672 m
- To
- 675 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:672-675
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows an exceptional gold grade, indicating a high-grade sub-interval within a broader zone, but its limited length and unknown true width are noted.
Positive factors
- Exceptional gold grade for porphyry
- Confirms high-grade sub-interval
Negative factors
- Short intercept length
- True width unknown
Evidence · table
“5.62”
Context: 3.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Gold grade of 5.62 g/t is well above the exceptional threshold for porphyry gold (1 g/t).
Evidence · table
“5.62”
Context: 3.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 10.2Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 10.2
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 672 m
- To
- 675 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:672-675
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade and short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low silver grade
- Short intercept length
- True width unknown
Evidence · table
“10.20”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.29Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.29
- Grade Unit
- %
- Intercept
- 3 m
- From
- 672 m
- To
- 675 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:672-675
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low copper grade
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.29*”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.25Grade Unit: g/tIntercept: 205 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 205 m
- From
- 715 m
- To
- 920 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:715-920
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very long intercept shows broad, low-grade gold mineralization at depth, which is positive for bulk tonnage potential, but the low grade and unknown true width are noted.
Positive factors
- Very long intercept length
- Confirms broad mineralization at depth
Negative factors
- Low gold grade
- True width unknown
Evidence · table
“0.25”
Context: 205.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 1.82Grade Unit: g/tIntercept: 205 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.82
- Grade Unit
- g/t
- Intercept
- 205 m
- From
- 715 m
- To
- 920 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:715-920
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very long intercept shows broad, very low-grade silver mineralization at depth, contributing marginally to the overall prospectivity.
Positive factors
- Very long intercept length
- Confirms broad mineralization at depth
Negative factors
- Very low silver grade
- True width unknown
Evidence · table
“1.82”
Context: 205.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.12Grade Unit: %Intercept: 205 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.12
- Grade Unit
- %
- Intercept
- 205 m
- From
- 715 m
- To
- 920 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:715-920
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very long intercept shows broad, low-grade copper mineralization at depth, which is positive for bulk tonnage potential, but the low grade and unknown true width are noted.
Positive factors
- Very long intercept length
- Confirms broad mineralization at depth
Negative factors
- Low copper grade
- True width unknown
Evidence · table
“0.12”
Context: 205.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.43Grade Unit: g/tIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.43
- Grade Unit
- g/t
- Intercept
- 16 m
- From
- 812 m
- To
- 828 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:812-828
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a moderate length, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low gold grade
- True width unknown
Evidence · table
“0.43”
Context: 16.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 3.37Grade Unit: g/tIntercept: 16 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 3.37
- Grade Unit
- g/t
- Intercept
- 16 m
- From
- 812 m
- To
- 828 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:812-828
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low silver grade
- True width unknown
Evidence · table
“3.37”
Context: 16.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.07Grade Unit: %Intercept: 16 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.07
- Grade Unit
- %
- Intercept
- 16 m
- From
- 812 m
- To
- 828 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:812-828
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows very low copper grade over a moderate length, contributing minimally to the overall prospectivity.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Very low copper grade
- True width unknown
Evidence · table
“0.07”
Context: 16.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.61Grade Unit: g/tIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.61
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 848 m
- To
- 863 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:848-863
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade over a moderate length, confirming mineralization at depth, but the unknown true width is a negative factor.
Positive factors
- Moderate gold grade for porphyry
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- True width unknown
Evidence · table
“0.61”
Context: 15.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 4.06Grade Unit: g/tIntercept: 15 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 4.06
- Grade Unit
- g/t
- Intercept
- 15 m
- From
- 848 m
- To
- 863 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:848-863
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low silver grade
- True width unknown
Evidence · table
“4.06”
Context: 15.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.21Grade Unit: %Intercept: 15 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.21
- Grade Unit
- %
- Intercept
- 15 m
- From
- 848 m
- To
- 863 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:848-863
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low copper grade over a moderate length, confirming mineralization but not indicating high economic potential.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low copper grade
- True width unknown
Evidence · table
“0.21”
Context: 15.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.3Grade Unit: g/tIntercept: 7.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.3
- Grade Unit
- g/t
- Intercept
- 7.3 m
- From
- 1007.7 m
- To
- 1015 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1007.7-1015
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low gold grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.30”
Context: 7.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 8.2Grade Unit: g/tIntercept: 7.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 8.2
- Grade Unit
- g/t
- Intercept
- 7.3 m
- From
- 1007.7 m
- To
- 1015 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1007.7-1015
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade over a moderate length at significant depth, contributing marginally to the overall prospectivity.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low silver grade
- Moderate intercept length
- True width unknown
Evidence · table
“8.20”
Context: 7.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.28Grade Unit: %Intercept: 7.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 7.3 m
- From
- 1007.7 m
- To
- 1015 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1007.7-1015
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low copper grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low copper grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.28”
Context: 7.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.23Grade Unit: g/tIntercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 11.3 m
- From
- 1097.7 m
- To
- 1109 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1097.7-1109
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low gold grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.23”
Context: 11.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 1.71Grade Unit: g/tIntercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.71
- Grade Unit
- g/t
- Intercept
- 11.3 m
- From
- 1097.7 m
- To
- 1109 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1097.7-1109
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is very low grade over a moderate length at significant depth, contributing marginally to the overall prospectivity.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Very low silver grade
- Moderate intercept length
- True width unknown
Evidence · table
“1.71”
Context: 11.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.26Grade Unit: %Intercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.26
- Grade Unit
- %
- Intercept
- 11.3 m
- From
- 1097.7 m
- To
- 1109 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1097.7-1109
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low copper grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low copper grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.26”
Context: 11.30
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · goldGrade: 0.29Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.29
- Grade Unit
- g/t
- Intercept
- 6 m
- From
- 1121 m
- To
- 1127 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1121-1127
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low gold grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.29”
Context: 6.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · silverGrade: 1.48Grade Unit: g/tIntercept: 6 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.48
- Grade Unit
- g/t
- Intercept
- 6 m
- From
- 1121 m
- To
- 1127 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1121-1127
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is very low grade over a moderate length at significant depth, contributing marginally to the overall prospectivity.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Very low silver grade
- Moderate intercept length
- True width unknown
Evidence · table
“1.48”
Context: 6.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-278Taguas · copperGrade: 0.19Grade Unit: %Intercept: 6 mView all detailsHide details
Identity
- Hole ID
- TADD-278
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 6 m
- From
- 1121 m
- To
- 1127 m
- Hole Depth
- 1331.7 m
- Intercept Depth
- 490 m
Classification
- Deposit Type
- porphyry
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-278:1121-1127
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low copper grade over a moderate length at significant depth, confirming mineralization but not indicating high economic potential.
Positive factors
- Confirms mineralization at significant depth
Negative factors
- Low copper grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.19”
Context: 6.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.15Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 361 m
- To
- 364 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:361-364
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low gold grade
- Short intercept length
- True width unknown
Evidence · table
“0.15”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 2.36Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 2.36
- Grade Unit
- g/t
- Intercept
- 3 m
- From
- 361 m
- To
- 364 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:361-364
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- Short intercept length
- True width unknown
Evidence · table
“2.36”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.41Grade Unit: %Intercept: 3 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.41
- Grade Unit
- %
- Intercept
- 3 m
- From
- 361 m
- To
- 364 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:361-364
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low copper grade
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.41*”
Context: 3.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.18Grade Unit: g/tIntercept: 7 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 7 m
- From
- 372 m
- To
- 379 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:372-379
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low gold grade over a moderate length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low gold grade
- Moderate intercept length
- True width unknown
Evidence · table
“0.18”
Context: 7.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 2.92Grade Unit: g/tIntercept: 7 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 2.92
- Grade Unit
- g/t
- Intercept
- 7 m
- From
- 372 m
- To
- 379 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:372-379
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low silver grade over a moderate length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- Moderate intercept length
- True width unknown
Evidence · table
“2.92”
Context: 7.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.43Grade Unit: %Intercept: 7 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.43
- Grade Unit
- %
- Intercept
- 7 m
- From
- 372 m
- To
- 379 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:372-379
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low copper grade over a moderate length, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low copper grade
- Moderate intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.43*”
Context: 7.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 2.44Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 2.44
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 398 m
- To
- 403 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:398-403
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a strong gold grade over a moderate length, indicating significant mineralization at depth, but the unknown true width is a negative factor.
Positive factors
- Strong gold grade for epithermal
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- True width unknown
Evidence · table
“2.44”
Context: 5.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 9.48Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 9.48
- Grade Unit
- g/t
- Intercept
- 5 m
- From
- 398 m
- To
- 403 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:398-403
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade over a moderate length, confirming mineralization but not indicating high economic potential.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low silver grade
- True width unknown
Evidence · table
“9.48”
Context: 5.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 1.69Grade Unit: %Intercept: 5 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.69
- Grade Unit
- %
- Intercept
- 5 m
- From
- 398 m
- To
- 403 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:398-403
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a strong copper grade over a moderate length, indicating significant mineralization at depth, but the unknown true width and presence of arsenic are negative factors.
Positive factors
- Strong copper grade for epithermal
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“1.69*”
Context: 5.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 9.19Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 9.19
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 398 m
- To
- 399.25 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:398-399.25
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very short intercept shows an exceptional gold grade (9.19 g/t), indicating a high-grade sub-interval within a broader zone, but its limited length and unknown true width are noted.
Positive factors
- Exceptional gold grade
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
Evidence · table
“9.19”
Context: 1.25
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Gold grade of 9.19 g/t is well above the exceptional threshold for epithermal gold (5 g/t).
Evidence · table
“9.19”
Context: 1.25
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 28.1Grade Unit: g/tIntercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 28.1
- Grade Unit
- g/t
- Intercept
- 1.25 m
- From
- 398 m
- To
- 399.25 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:398-399.25
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low silver grade
- Very short intercept length
- True width unknown
Evidence · table
“28.10”
Context: 1.25
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 5.55Grade Unit: %Intercept: 1.25 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 5.55
- Grade Unit
- %
- Intercept
- 1.25 m
- From
- 398 m
- To
- 399.25 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:398-399.25
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.
Positive factors
- Exceptional copper grade for epithermal
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“5.55*”
Context: 1.25
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Copper grade of 5.55% is well above the exceptional threshold for epithermal copper (2.5%).
Evidence · table
“5.55*”
Context: 1.25
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.19Grade Unit: g/tIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.19
- Grade Unit
- g/t
- Intercept
- 17 m
- From
- 427 m
- To
- 444 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:427-444
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a moderate length, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low gold grade
- True width unknown
Evidence · table
“0.19”
Context: 17.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 2.04Grade Unit: g/tIntercept: 17 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 2.04
- Grade Unit
- g/t
- Intercept
- 17 m
- From
- 427 m
- To
- 444 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:427-444
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is very low grade over a moderate length, contributing minimally to the overall prospectivity.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- True width unknown
Evidence · table
“2.04”
Context: 17.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.28Grade Unit: %Intercept: 17 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.28
- Grade Unit
- %
- Intercept
- 17 m
- From
- 427 m
- To
- 444 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:427-444
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low copper grade over a moderate length, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Moderate intercept length
- Confirms mineralization at depth
Negative factors
- Low copper grade
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.28*”
Context: 17.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 1.12Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.12
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 439 m
- To
- 440 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:439-440
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very short intercept shows a moderate gold grade, indicating a high-grade sub-interval within a broader zone, but its limited length and unknown true width are noted.
Positive factors
- Moderate gold grade for epithermal
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
Evidence · table
“1.12”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 20.6Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 20.6
- Grade Unit
- g/t
- Intercept
- 1 m
- From
- 439 m
- To
- 440 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:439-440
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This silver intercept is low grade and very short, contributing marginally to the overall prospectivity, though it confirms the presence of mineralization.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low silver grade
- Very short intercept length
- True width unknown
Evidence · table
“20.60”
Context: 1.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 3.49Grade Unit: %Intercept: 1 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 3.49
- Grade Unit
- %
- Intercept
- 1 m
- From
- 439 m
- To
- 440 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:439-440
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This very short intercept shows an exceptional copper grade, indicating a high-grade sub-interval within a broader zone, but its limited length and presence of arsenic are noted.
Positive factors
- Exceptional copper grade for epithermal
- Confirms high-grade sub-interval
Negative factors
- Very short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“3.49*”
Context: 1.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Copper grade of 3.49% is well above the exceptional threshold for epithermal copper (2.5%).
Evidence · table
“3.49*”
Context: 1.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.25Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 470 m
- To
- 472 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:470-472
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low gold grade
- Short intercept length
- True width unknown
Evidence · table
“0.25”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 3.2Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 3.2
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 470 m
- To
- 472 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:470-472
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- Short intercept length
- True width unknown
Evidence · table
“3.20”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.36Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.36
- Grade Unit
- %
- Intercept
- 2 m
- From
- 470 m
- To
- 472 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:470-472
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low copper grade
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.36*”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.57Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.57
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 648 m
- To
- 650 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:648-650
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a short length, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low gold grade
- Short intercept length
- True width unknown
Evidence · table
“0.57”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 1.1Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.1
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 648 m
- To
- 650 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:648-650
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- Short intercept length
- True width unknown
Evidence · table
“1.10”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.17Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.17
- Grade Unit
- %
- Intercept
- 2 m
- From
- 648 m
- To
- 650 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:648-650
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a very low copper grade, contributing minimally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low copper grade
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.17*”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.64Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.64
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 686 m
- To
- 688 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:686-688
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a low gold grade over a short length, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low gold grade
- Short intercept length
- True width unknown
Evidence · table
“0.64”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 0.25Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.25
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 686 m
- To
- 688 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:686-688
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- Short intercept length
- True width unknown
Evidence · table
“0.25”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.02Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.02
- Grade Unit
- %
- Intercept
- 2 m
- From
- 686 m
- To
- 688 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:686-688
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows an extremely low copper grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Extremely low copper grade
- Short intercept length
- True width unknown
Evidence · table
“0.02”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · goldGrade: 0.18Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.18
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 756 m
- To
- 758 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:756-758
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low gold grade
- Short intercept length
- True width unknown
Evidence · table
“0.18”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 38.7Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 38.7
- Grade Unit
- g/t
- Intercept
- 2 m
- From
- 756 m
- To
- 758 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:756-758
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade over a short length, confirming mineralization but not indicating high economic potential on its own.
Positive factors
- Moderate silver grade for epithermal
- Confirms mineralization at depth
Negative factors
- Short intercept length
- True width unknown
Evidence · table
“38.70”
Context: 2.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 7.19Grade Unit: %Intercept: 2 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 7.19
- Grade Unit
- %
- Intercept
- 2 m
- From
- 756 m
- To
- 758 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:756-758
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows an exceptional copper grade (7.19%), indicating strong mineralization at depth, but its limited length and presence of arsenic are noted.
Positive factors
- Exceptional copper grade for epithermal
- Confirms mineralization at depth
Negative factors
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“7.19*”
Context: 2.00
Tags used in scoring
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Copper grade of 7.19% is well above the exceptional threshold for epithermal copper (2.5%).
Evidence · table
“7.19*”
Context: 2.00
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: deleterious_flag is true
TADD-279Taguas · goldGrade: 0.16Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- gold
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.16
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 836 m
- To
- 840 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:836-840
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low gold grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low gold grade
- Short intercept length
- True width unknown
Evidence · table
“0.16”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · silverGrade: 1.9Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- silver
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 1.9
- Grade Unit
- g/t
- Intercept
- 4 m
- From
- 836 m
- To
- 840 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:836-840
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This intercept shows a very low silver grade over a short length, contributing minimally to the overall prospectivity.
Positive factors
- Confirms mineralization at depth
Negative factors
- Very low silver grade
- Short intercept length
- True width unknown
Evidence · table
“1.90”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
TADD-279Taguas · copperGrade: 0.36Grade Unit: %Intercept: 4 mView all detailsHide details
Identity
- Hole ID
- TADD-279
- Project
- Taguas
- Commodity
- copper
- Region
- argentina
- Reported Region
- argentina
- Ticker
- ORV
Geometry
- Grade
- 0.36
- Grade Unit
- %
- Intercept
- 4 m
- From
- 836 m
- To
- 840 m
- Hole Depth
- 842 m
- Intercept Depth
- 361 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- drill
- Group ID
- TADD-279:836-840
- Mining Method
- unknown
QA/QC
- Laboratory
- Alex Stewart International Argentina SA Laboratory in Mendoza
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Deleterious
- Deleterious Flag
- Yes
- Deleterious Elements
- arsenic
Metal Equivalent
- Assumptions Disclosed
- No
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-02T00:00:00.000Z
Reasoning: This short intercept shows a low copper grade, contributing marginally to the overall prospectivity, and the presence of arsenic-bearing enargite is a negative factor.
Positive factors
- Confirms mineralization at depth
Negative factors
- Low copper grade
- Short intercept length
- True width unknown
- Presence of arsenic-bearing enargite
Evidence · table
“0.36*”
Context: 4.00
Tags used in scoring
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: Intercept reported as downhole length with no true width stated.
Evidence · text
“Intercepts reported are downhole lengths unless otherwise stated, and true widths are not yet known.”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: Release includes QA/QC disclosure, certified lab, QP sign-off, and stated methods.
Evidence · text
“The reported work has been completed using industry standard procedures, including a quality assurance/quality control ("QA/QC") program consisting of the insertion of quarter core field duplicates, coarse duplicates split after laboratory crushing, pulp duplicates split after laboratory pulverization, coarse analytical blank samples and 2 different CRMs inserted in batches of roughly 50 samples.”
Deleterious Elements Presentnegative
A source-stated penalty, refractory or recovery concern in the fact's scope. Element detection alone, including measured elements explicitly below penalty thresholds, does not trigger this tag. Respect negation and retain a separately stated concern even when another risk is explicitly absent.
Why it applies: Copper content is primarily associated with the presence of enargite (Cu₃AsS₄), indicating arsenic.
Evidence · text
“Copper content is primarily associated with the presence of enargite (Cu ₃ AsS ₄ ), characteristic of high-sulfidation epithermal systems .”
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.