OUTCROP SILVER CONTINUES TO EXTEND LOS MANGOS VEIN TO THE NORTH

Original announcement by tmx on

Company
Outcrop Silver & Gold Corporation
Ticker
OCG
Exchange
TSX
Region
Colombia
Primary commodity
Silver
Secondary commodities
Gold
Document categories
Drill results
Extracted
2026-09-16 15:17:23 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Outcrop Silver & Gold Corporation announced high-grade silver and gold assay results from step-out drilling at the Los Mangos vein within its Santa Ana project in Colombia. Key intercepts include 1.88 metres grading 507 g/t Ag and 0.03 g/t Au (509 g/t AgEq) and 2.11 metres grading 445 g/t Ag and 2.14 g/t Au (606 g/t AgEq) in hole DH476, extending the vein to the north and at depth. The company highlights strong continuity and grade, with all results supported by disclosed QA/QC protocols and true width estimates.

Reasoning: The document reports significant high-grade silver and gold drill results from step-out drilling at the Los Mangos vein, successfully extending the known mineralization to the north and at depth. The results demonstrate strong continuity and are supported by transparent QA/QC and true width estimates, indicating a positive development for the project.

Positive factors

  • High-grade silver and gold intercepts
  • Extension of mineralization along strike and at depth
  • True width estimated and disclosed for all intercepts
  • Strong continuity of the vein system demonstrated
  • Comprehensive QA/QC procedures disclosed with QP sign-off and accredited lab

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 16

Extracted facts

Stored fact records: 16. Some facts used in scoring do not have a stored record.

Drill Results (16)

DH476Santa Ana · silverGrade: 507Grade Unit: g/tIntercept: 1.88 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
507
Grade Unit
g/t
Intercept
1.88 m
True Width
1.41 m
From
224.03 m
To
225.91 m
Hole Depth
285.65 m
Intercept Depth
224.03 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:224.03-225.91
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
509
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows an exceptional silver grade over a moderate width, with true width disclosed, contributing to the extension of the Los Mangos vein.

Positive factors

  • Exceptional silver grade (507 g/t)
  • True width of 1.41 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“507”

Context: 1.88

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 1.41 m is explicitly stated for this intercept.

Evidence · table

“1.41”

Context: 1.88

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The silver grade of 507 g/t is above the exceptional threshold for silver (>=500 g/t).

Evidence · table

“507”

Context: 1.88

DH476Santa Ana · goldGrade: 0.03Grade Unit: g/tIntercept: 1.88 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
1.88 m
True Width
1.41 m
From
224.03 m
To
225.91 m
Hole Depth
285.65 m
Intercept Depth
224.03 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:224.03-225.91
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
509
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, but is part of a broader high-grade silver intercept with true width disclosed, contributing to the extension of the Los Mangos vein.

Positive factors

  • True width of 1.41 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“0.03”

Context: 1.88

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 1.41 m is explicitly stated for this intercept.

Evidence · table

“1.41”

Context: 1.88

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

DH476Santa Ana · silverGrade: 1306Grade Unit: g/tIntercept: 0.68 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1306
Grade Unit
g/t
Intercept
0.68 m
True Width
0.51 m
From
225.23 m
To
225.91 m
Hole Depth
285.65 m
Intercept Depth
225.23 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:225.23-225.91
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1308
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This sub-interval shows a bonanza silver grade over a narrow width, with true width disclosed, significantly enhancing the overall intercept's value.

Positive factors

  • Bonanza silver grade (1306 g/t)
  • True width of 0.51 m disclosed
  • Part of a broader high-grade intercept

Evidence · table

“1,306”

Context: 0.68

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 1306 g/t is exceptionally high, well above the exceptional threshold for silver (>=500 g/t).

Evidence · table

“1,306”

Context: 0.68

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.51 m is explicitly stated for this intercept.

Evidence · table

“0.51”

Context: 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

DH476Santa Ana · goldGrade: 0.03Grade Unit: g/tIntercept: 0.68 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.68 m
True Width
0.51 m
From
225.23 m
To
225.91 m
Hole Depth
285.65 m
Intercept Depth
225.23 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:225.23-225.91
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1308
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This sub-interval shows a weak gold grade, but is part of a broader bonanza-grade silver intercept with true width disclosed.

Positive factors

  • True width of 0.51 m disclosed
  • Part of a broader high-grade intercept

Evidence · table

“0.03”

Context: 0.68

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.51 m is explicitly stated for this intercept.

Evidence · table

“0.51”

Context: 0.68

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

DH476Santa Ana · silverGrade: 445Grade Unit: g/tIntercept: 2.11 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
445
Grade Unit
g/t
Intercept
2.11 m
True Width
1.59 m
From
242.99 m
To
245.1 m
Hole Depth
285.65 m
Intercept Depth
242.99 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:242.99-245.1
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
606
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a moderate width, with true width disclosed, contributing to the extension of the Los Mangos vein.

Positive factors

  • Strong silver grade (445 g/t)
  • True width of 1.59 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“445”

Context: 2.11

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 1.59 m is explicitly stated for this intercept.

Evidence · table

“1.59”

Context: 2.11

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The silver grade of 445 g/t is above the strong threshold for silver (>=200 g/t).

Evidence · table

“445”

Context: 2.11

DH476Santa Ana · goldGrade: 2.14Grade Unit: g/tIntercept: 2.11 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
2.14
Grade Unit
g/t
Intercept
2.11 m
True Width
1.59 m
From
242.99 m
To
245.1 m
Hole Depth
285.65 m
Intercept Depth
242.99 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:242.99-245.1
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
606
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows a strong gold grade over a moderate width, with true width disclosed, contributing to the extension of the Los Mangos vein.

Positive factors

  • Strong gold grade (2.14 g/t)
  • True width of 1.59 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“2.14”

Context: 2.11

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 1.59 m is explicitly stated for this intercept.

Evidence · table

“1.59”

Context: 2.11

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The gold grade of 2.14 g/t is above the strong threshold for gold (>=2 g/t).

Evidence · table

“2.14”

Context: 2.11

DH476Santa Ana · silverGrade: 333Grade Unit: g/tIntercept: 0.63 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
333
Grade Unit
g/t
Intercept
0.63 m
True Width
0.47 m
From
243.57 m
To
244.2 m
Hole Depth
285.65 m
Intercept Depth
243.57 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:243.57-244.2
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
606
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow width, with true width disclosed, contributing to the overall high-grade intercept.

Positive factors

  • Strong silver grade (333 g/t)
  • True width of 0.47 m disclosed
  • Part of a broader high-grade intercept

Evidence · table

“333”

Context: 0.63

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.47 m is explicitly stated for this intercept.

Evidence · table

“0.47”

Context: 0.63

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The silver grade of 333 g/t is above the strong threshold for silver (>=200 g/t).

Evidence · table

“333”

Context: 0.63

DH476Santa Ana · goldGrade: 3.64Grade Unit: g/tIntercept: 0.63 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
3.64
Grade Unit
g/t
Intercept
0.63 m
True Width
0.47 m
From
243.57 m
To
244.2 m
Hole Depth
285.65 m
Intercept Depth
243.57 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:243.57-244.2
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
606
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This sub-interval shows a strong gold grade over a narrow width, with true width disclosed, contributing to the overall high-grade intercept.

Positive factors

  • Strong gold grade (3.64 g/t)
  • True width of 0.47 m disclosed
  • Part of a broader high-grade intercept

Evidence · table

“3.64”

Context: 0.63

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.47 m is explicitly stated for this intercept.

Evidence · table

“0.47”

Context: 0.63

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The gold grade of 3.64 g/t is above the strong threshold for gold (>=2 g/t).

Evidence · table

“3.64”

Context: 0.63

DH476Santa Ana · silverGrade: 1663Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1663
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
244.2 m
To
244.6 m
Hole Depth
285.65 m
Intercept Depth
244.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:244.2-244.6
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1932
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This sub-interval shows bonanza silver and strong gold grades over a narrow width, with true width disclosed, significantly enhancing the overall intercept's value.

Positive factors

  • Bonanza silver grade (1663 g/t)
  • Strong gold grade (3.59 g/t)
  • True width of 0.30 m disclosed

Evidence · table

“1,663”

Context: 0.40

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 1663 g/t is exceptionally high, well above the exceptional threshold for silver (>=500 g/t).

Evidence · table

“1,663”

Context: 0.40

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.30 m is explicitly stated for this intercept.

Evidence · table

“0.30”

Context: 0.40

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The gold grade of 3.59 g/t is above the strong threshold for gold (>=2 g/t).

Evidence · table

“3.59”

Context: 0.40

DH476Santa Ana · goldGrade: 3.59Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
DH476
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
3.59
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
244.2 m
To
244.6 m
Hole Depth
285.65 m
Intercept Depth
244.2 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH476:244.2-244.6
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.204
Northing
556537.565
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.9 m
Azimuth
331 °
Dip
-46 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1932
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This sub-interval shows a strong gold grade over a narrow width, with true width disclosed, contributing to the overall high-grade intercept.

Positive factors

  • Strong gold grade (3.59 g/t)
  • True width of 0.30 m disclosed
  • Part of a broader high-grade intercept

Evidence · table

“3.59”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.30 m is explicitly stated for this intercept.

Evidence · table

“0.30”

Context: 0.40

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The gold grade of 3.59 g/t is above the strong threshold for gold (>=2 g/t).

Evidence · table

“3.59”

Context: 0.40

DH478Santa Ana · silverGrade: 243Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
DH478
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
243
Grade Unit
g/t
Intercept
0.4 m
True Width
0.28 m
From
248.05 m
To
248.45 m
Hole Depth
343.2 m
Intercept Depth
248.05 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH478:248.05-248.45
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.42
Northing
556537.967
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.02 m
Azimuth
345 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
245
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows a strong silver grade over a narrow width, with true width disclosed, contributing to the extension of the Los Mangos vein.

Positive factors

  • Strong silver grade (243 g/t)
  • True width of 0.28 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“243”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.28 m is explicitly stated for this intercept.

Evidence · table

“0.28”

Context: 0.40

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

High RecoveryRejected · positive · Story-specific tag

Recovery at or above the exceptional band for the commodity and processing route.

Reason: The silver grade of 243 g/t is above the strong threshold for silver (>=200 g/t).

Evidence · table

“243”

Context: 0.40

DH478Santa Ana · goldGrade: 0.03Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
DH478
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
0.4 m
True Width
0.28 m
From
248.05 m
To
248.45 m
Hole Depth
343.2 m
Intercept Depth
248.05 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH478:248.05-248.45
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.42
Northing
556537.967
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.02 m
Azimuth
345 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
245
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, but is part of a broader high-grade silver intercept with true width disclosed.

Positive factors

  • True width of 0.28 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“0.03”

Context: 0.40

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.28 m is explicitly stated for this intercept.

Evidence · table

“0.28”

Context: 0.40

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

DH478Santa Ana · silverGrade: 709Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
DH478
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
709
Grade Unit
g/t
Intercept
0.3 m
True Width
0.21 m
From
311.44 m
To
311.74 m
Hole Depth
343.2 m
Intercept Depth
311.44 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH478:311.44-311.74
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.42
Northing
556537.967
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.02 m
Azimuth
345 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
712
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows an exceptional silver grade over a narrow width, with true width disclosed, contributing to the extension of the Los Mangos vein.

Positive factors

  • Exceptional silver grade (709 g/t)
  • True width of 0.21 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“709”

Context: 0.30

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 709 g/t is exceptionally high, well above the exceptional threshold for silver (>=500 g/t).

Evidence · table

“709”

Context: 0.30

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.21 m is explicitly stated for this intercept.

Evidence · table

“0.21”

Context: 0.30

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

DH478Santa Ana · goldGrade: 0.04Grade Unit: g/tIntercept: 0.3 mView all details
Link to this fact

Identity

Hole ID
DH478
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.04
Grade Unit
g/t
Intercept
0.3 m
True Width
0.21 m
From
311.44 m
To
311.74 m
Hole Depth
343.2 m
Intercept Depth
311.44 m

Classification

Program
exploration
Sample Type
drill
Group ID
DH478:311.44-311.74
Mining Method
unknown

Location

Location
Los Mangos
Easting
502041.42
Northing
556537.967
CRS
UTM system, zone 18N
EPSG
32618
Elevation
851.02 m
Azimuth
345 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
712
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: This intercept shows a weak gold grade, but is part of a broader exceptional-grade silver intercept with true width disclosed.

Positive factors

  • True width of 0.21 m disclosed
  • Step-out drilling extending mineralization

Evidence · table

“0.04”

Context: 0.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: The estimated true width of 0.21 m is explicitly stated for this intercept.

Evidence · table

“0.21”

Context: 0.30

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release includes a detailed QA/QC section, mentioning certified labs, QP sign-off, and methods like blanks, standards, and duplicates.

Evidence · text

“QA/QC Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW depending on the depth of the drill hole. Diamond drill core boxes were photographed, sawed, sampled and tagged. Samples were bagged, tagged and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP-multi-elemental analysis with code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted at approximately three control samples every twenty samples into the sample stream, monitoring laboratory performance. A comparison of control samples and their standard deviations indicates acceptable accuracy of the assays and no detectible contamination. No material QA/QC issues have been identified with respect to sample collection, security and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document explicitly states these are 'step-out drilling' results aimed at extending the Los Mangos vein to the north.

Evidence · text

“additional high-grade assay results from step-out drilling at the Los Mangos vein within the Santa Ana high-grade silver project in Colombia .”

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

AndSanta Ana · silverGrade: 1663Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
And
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1663
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
244.2 m
To
244.6 m
Intercept Depth
244.2 m

Classification

Sample Type
drill
Group ID
And:244.2-244.6
Mining Method
unknown

Location

Location
Los Mangos
CRS
UTM system, zone 18N
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1932
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: Expanded from assay table. 1663 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 665.2 g/t·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 1663 g/t silver is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1,663”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

AndSanta Ana · goldGrade: 3.59Grade Unit: g/tIntercept: 0.4 mView all details
Link to this fact

Identity

Hole ID
And
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
3.59
Grade Unit
g/t
Intercept
0.4 m
True Width
0.3 m
From
244.2 m
To
244.6 m
Intercept Depth
244.2 m

Classification

Sample Type
drill
Group ID
And:244.2-244.6
Mining Method
unknown

Location

Location
Los Mangos
CRS
UTM system, zone 18N
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1932
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-08-07T00:00:00.000Z

Reasoning: Expanded from assay table. 3.59 g/t gold is strong against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.4 g/t·m is below (grade alone is strong; the better of the two is used).

Positive factors

  • 3.59 g/t gold is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.59”

Context: And

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.