OUTCROP SILVER EXTENDS AGUILAR VEIN 450 METRES SOUTH AND IDENTIFIES POTENTIAL NEW HIGH-GRADE SHOOTS IN BLIND TARGETS

Original announcement by tmx on

Company
Outcrop Silver & Gold Corporation
Ticker
OCG
Exchange
TSX
Region
Colombia
Primary commodity
Silver
Secondary commodities
Gold
Document categories
Drill results, Resource update
Extracted
2026-09-16 15:14:56 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Outcrop Silver announced new drill results from its Santa Ana project in Colombia, extending the Aguilar vein system by 450 metres to the south and identifying new high-grade shoots in blind targets. Key intercepts include 0.45 metres grading 3,080 g/t AgEq in DH535 and 0.74 metres grading 1,084 g/t AgEq in DH524. The company continues drilling with three rigs in preparation for a Q1 2026 mineral resource update, with these results significantly expanding the known footprint and reinforcing the project's scalability.

Reasoning: The drill results demonstrate a significant step-out extension of the high-grade Aguilar vein system, with several bonanza-grade intercepts in previously blind targets, substantially expanding the known mineralized footprint and supporting future resource growth. The company also provided detailed QA/QC and QP sign-off, enhancing confidence in the results, though the lack of true width estimates for step-out holes is a minor drawback.

Positive factors

  • Significant extension of the Aguilar vein system by 450 metres to the south in blind targets, indicating strong exploration potential.
  • Multiple high-grade silver and gold intercepts, including bonanza grades, well above project and peer averages.
  • Confirmation of continuity beneath younger cover and identification of potential new high-grade shoots.
  • Comprehensive QA/QC procedures disclosed and a Qualified Person has signed off on the technical information.

Negative factors

  • True width of intercepts could not be estimated for the step-out holes, which may overstate actual thickness.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 39

Extracted facts

Stored fact records: 39. Some facts used in scoring do not have a stored record.

Drill Results (39)

DH508Santa Ana · silverGrade: 118Grade Unit: g/tIntercept: 1.12 mView all details
Link to this fact

Identity

Hole ID
DH508
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
118
Grade Unit
g/t
Intercept
1.12 m
From
72.53 m
To
73.65 m
Hole Depth
110.33 m
Intercept Depth
72.53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH508:72.53-73.65
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
166
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 118 g/t Ag over 1.12m is a good result, contributing to the overall extension of the vein system, though not as high-grade as other intercepts in the release. It is above the peer average of 86.788 g/t Ag.

Positive factors

  • Solid silver grade for the intercept.
  • Part of a significant step-out drilling program.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“118”

Context: 1.12

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH508Santa Ana · goldGrade: 0.54Grade Unit: g/tIntercept: 1.12 mView all details
Link to this fact

Identity

Hole ID
DH508
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.54
Grade Unit
g/t
Intercept
1.12 m
From
72.53 m
To
73.65 m
Hole Depth
110.33 m
Intercept Depth
72.53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH508:72.53-73.65
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
166
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 0.54 g/t over 1.12m is below the project's average gold grade, but still contributes to the overall AgEq value and confirms polymetallic mineralization in the step-out area.

Positive factors

  • Contributes to the overall polymetallic nature of the intercept.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“0.54”

Context: 1.12

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH508Santa Ana · silverGrade: 315Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
DH508
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
315
Grade Unit
g/t
Intercept
0.35 m
From
73.3 m
To
73.65 m
Hole Depth
110.33 m
Intercept Depth
72.53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH508:73.3-73.65
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
400
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 315 g/t Ag over 0.35m is a strong high-grade intercept, well above the peer average of 86.788 g/t Ag, and contributes positively to the overall prospectivity of the extended vein.

Positive factors

  • High-grade silver intercept, significantly above peer average.
  • Confirms high-grade mineralization within the broader interval.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“315”

Context: 0.35

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH508Santa Ana · goldGrade: 0.97Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
DH508
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.97
Grade Unit
g/t
Intercept
0.35 m
From
73.3 m
To
73.65 m
Hole Depth
110.33 m
Intercept Depth
72.53 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH508:73.3-73.65
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
400
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 0.97 g/t over 0.35m, while below the project average, enhances the overall AgEq grade for this high-grade sub-interval.

Positive factors

  • Contributes to the high AgEq value of the included interval.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“0.97”

Context: 0.35

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · silverGrade: 198Grade Unit: g/tIntercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
198
Grade Unit
g/t
Intercept
1.04 m
From
91.22 m
To
92.26 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:91.22-92.26
Mining Method
underground

Location

Location
Aguilar Splay
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
342
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 198 g/t Ag over 1.04m is a good result, confirming high-grade mineralization in a splay structure and contributing to the overall extension of the vein system. It is above the peer average of 86.788 g/t Ag.

Positive factors

  • Strong silver grade, well above peer average.
  • Indicates mineralization in an Aguilar Splay structure.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“198”

Context: 1.04

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · goldGrade: 1.63Grade Unit: g/tIntercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1.63
Grade Unit
g/t
Intercept
1.04 m
From
91.22 m
To
92.26 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:91.22-92.26
Mining Method
underground

Location

Location
Aguilar Splay
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
342
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 1.63 g/t over 1.04m, while below the project average, adds to the AgEq value and confirms polymetallic mineralization in the splay structure.

Positive factors

  • Contributes to the overall polymetallic nature of the intercept.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“1.63”

Context: 1.04

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · silverGrade: 411Grade Unit: g/tIntercept: 0.44 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
411
Grade Unit
g/t
Intercept
0.44 m
From
91.22 m
To
91.66 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:91.22-91.66
Mining Method
underground

Location

Location
Aguilar Splay
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
718
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 411 g/t Ag over 0.44m is a very strong high-grade intercept, well above the peer average of 86.788 g/t Ag, and contributes positively to the overall prospectivity of the extended vein.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Confirms high-grade mineralization within the broader interval.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“411”

Context: 0.44

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · goldGrade: 3.49Grade Unit: g/tIntercept: 0.44 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
3.49
Grade Unit
g/t
Intercept
0.44 m
From
91.22 m
To
91.66 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:91.22-91.66
Mining Method
underground

Location

Location
Aguilar Splay
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
718
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 3.49 g/t over 0.44m is a good result, though below the project average, and significantly boosts the AgEq grade for this high-grade sub-interval in the splay structure.

Positive factors

  • Good gold grade, contributing significantly to the AgEq value.
  • Confirms polymetallic nature of the mineralization.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“3.49”

Context: 0.44

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · silverGrade: 363Grade Unit: g/tIntercept: 0.71 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
363
Grade Unit
g/t
Intercept
0.71 m
From
98.47 m
To
99.18 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:98.47-99.18
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
558
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This intercept of 363 g/t Ag over 0.71m is a very strong high-grade result, well above the peer average of 86.788 g/t Ag, and reinforces the high-grade potential of the Aguilar vein.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Confirms high-grade mineralization in the Aguilar vein.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“363”

Context: 0.71

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · goldGrade: 2.21Grade Unit: g/tIntercept: 0.71 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
2.21
Grade Unit
g/t
Intercept
0.71 m
From
98.47 m
To
99.18 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:98.47-99.18
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
558
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 2.21 g/t over 0.71m is a good result, though below the project average, and significantly boosts the AgEq grade for this interval in the Aguilar vein.

Positive factors

  • Good gold grade, contributing significantly to the AgEq value.
  • Confirms polymetallic nature of the mineralization.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“2.21”

Context: 0.71

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · silverGrade: 685Grade Unit: g/tIntercept: 0.37 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
685
Grade Unit
g/t
Intercept
0.37 m
From
98.47 m
To
98.84 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:98.47-98.84
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1049
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 685 g/t Ag over 0.37m is a bonanza-grade intercept, well above the peer average of 86.788 g/t Ag, and strongly supports the high-grade potential of the Aguilar vein.

Positive factors

  • Bonanza-grade silver intercept, significantly above peer average and project average.
  • Confirms high-grade mineralization within the broader interval.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“685”

Context: 0.37

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 685 g/t over 0.37m is exceptionally high, well above the deposit-type norm of 86.788 g/t Ag.

Evidence · table

“685”

Context: 0.37

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH509Santa Ana · goldGrade: 4.12Grade Unit: g/tIntercept: 0.37 mView all details
Link to this fact

Identity

Hole ID
DH509
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
4.12
Grade Unit
g/t
Intercept
0.37 m
From
98.47 m
To
98.84 m
Hole Depth
115.85 m
Intercept Depth
91.22 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH509:98.47-98.84
Mining Method
underground

Location

Location
Aguilar
Easting
503593.713
Northing
561039.824
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1033.4 m
Azimuth
153 °
Dip
-86 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1049
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 4.12 g/t over 0.37m is a strong result, though below the project average, and significantly boosts the AgEq grade for this bonanza-grade sub-interval in the Aguilar vein.

Positive factors

  • Strong gold grade, contributing significantly to the bonanza AgEq value.
  • Confirms polymetallic nature of the mineralization.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“4.12”

Context: 0.37

Tags used in scoring

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH514Santa Ana · silverGrade: 197Grade Unit: g/tIntercept: 0.77 mView all details
Link to this fact

Identity

Hole ID
DH514
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
197
Grade Unit
g/t
Intercept
0.77 m
From
83.19 m
To
83.96 m
Intercept Depth
83.19 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH514:83.19-83.96
Mining Method
underground

Location

Location
Aguilar
Easting
503311.004
Northing
560821.696
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.53 m
Azimuth
89 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
439
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 197 g/t Ag over 0.77m is a good result, significantly above the peer average of 86.788 g/t Ag, and is important as it's part of the 450m step-out extension.

Positive factors

  • Strong silver grade, well above peer average.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“197”

Context: 0.77

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH514 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH514Santa Ana · goldGrade: 2.74Grade Unit: g/tIntercept: 0.77 mView all details
Link to this fact

Identity

Hole ID
DH514
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
2.74
Grade Unit
g/t
Intercept
0.77 m
From
83.19 m
To
83.96 m
Intercept Depth
83.19 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH514:83.19-83.96
Mining Method
underground

Location

Location
Aguilar
Easting
503311.004
Northing
560821.696
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.53 m
Azimuth
89 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
439
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 2.74 g/t over 0.77m, while below the project average, adds to the AgEq value and is important as part of the 450m step-out extension.

Positive factors

  • Good gold grade, contributing significantly to the AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“2.74”

Context: 0.77

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH514 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH514Santa Ana · silverGrade: 360Grade Unit: g/tIntercept: 0.39 mView all details
Link to this fact

Identity

Hole ID
DH514
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
360
Grade Unit
g/t
Intercept
0.39 m
From
83.19 m
To
83.58 m
Intercept Depth
83.19 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH514:83.19-83.58
Mining Method
underground

Location

Location
Aguilar
Easting
503311.004
Northing
560821.696
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.53 m
Azimuth
89 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
811
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 360 g/t Ag over 0.39m is a very strong high-grade intercept, well above the peer average of 86.788 g/t Ag, and is a key part of the 450m step-out extension.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Confirms high-grade mineralization within the broader interval as part of a significant step-out.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“360”

Context: 0.39

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH514 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH514Santa Ana · goldGrade: 5.11Grade Unit: g/tIntercept: 0.39 mView all details
Link to this fact

Identity

Hole ID
DH514
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
5.11
Grade Unit
g/t
Intercept
0.39 m
From
83.19 m
To
83.58 m
Intercept Depth
83.19 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH514:83.19-83.58
Mining Method
underground

Location

Location
Aguilar
Easting
503311.004
Northing
560821.696
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.53 m
Azimuth
89 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
811
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 5.11 g/t over 0.39m is a strong result, though below the project average, and significantly boosts the AgEq grade for this high-grade sub-interval in the 450m step-out extension.

Positive factors

  • Strong gold grade, contributing significantly to the high AgEq value.
  • Confirms polymetallic nature of the mineralization as part of a significant step-out.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“5.11”

Context: 0.39

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH514 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH514Santa Ana · silverGrade: 455Grade Unit: g/tIntercept: 0.31 mView all details
Link to this fact

Identity

Hole ID
DH514
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
455
Grade Unit
g/t
Intercept
0.31 m
From
87.45 m
To
87.76 m
Intercept Depth
83.19 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH514:87.45-87.76
Mining Method
underground

Location

Location
Aguilar Splay
Easting
503311.004
Northing
560821.696
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.53 m
Azimuth
89 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
613
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This intercept of 455 g/t Ag over 0.31m is a very strong high-grade result, well above the peer average of 86.788 g/t Ag, and is important as part of the 450m step-out extension in a splay structure.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Indicates mineralization in an Aguilar Splay structure as part of a significant step-out.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“455”

Context: 0.31

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH514 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH514Santa Ana · goldGrade: 1.79Grade Unit: g/tIntercept: 0.31 mView all details
Link to this fact

Identity

Hole ID
DH514
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1.79
Grade Unit
g/t
Intercept
0.31 m
From
87.45 m
To
87.76 m
Intercept Depth
83.19 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH514:87.45-87.76
Mining Method
underground

Location

Location
Aguilar Splay
Easting
503311.004
Northing
560821.696
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.53 m
Azimuth
89 °
Dip
-47 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
613
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 1.79 g/t over 0.31m, while below the project average, adds to the AgEq value and is important as part of the 450m step-out extension in a splay structure.

Positive factors

  • Contributes to the AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“1.79”

Context: 0.31

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH514 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH517Santa Ana · silverGrade: 94Grade Unit: g/tIntercept: 0.63 mView all details
Link to this fact

Identity

Hole ID
DH517
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
94
Grade Unit
g/t
Intercept
0.63 m
From
95.05 m
To
95.68 m
Intercept Depth
95.05 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH517:95.05-95.68
Mining Method
underground

Location

Location
Aguilar
Easting
503311.481
Northing
560821.686
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.48 m
Azimuth
89 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
162
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 94 g/t Ag over 0.63m is above the peer average of 86.788 g/t Ag, but the AgEq grade is only slightly above the cut-off. Its significance lies in being part of the 450m step-out extension.

Positive factors

  • Silver grade is above the peer average.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.
  • AgEq grade is just above the stated cut-off of 150 g/t AgEq.

Evidence · table

“94”

Context: 0.63

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH517 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH517Santa Ana · goldGrade: 0.77Grade Unit: g/tIntercept: 0.63 mView all details
Link to this fact

Identity

Hole ID
DH517
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.77
Grade Unit
g/t
Intercept
0.63 m
From
95.05 m
To
95.68 m
Intercept Depth
95.05 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH517:95.05-95.68
Mining Method
underground

Location

Location
Aguilar
Easting
503311.481
Northing
560821.686
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.48 m
Azimuth
89 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
162
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 0.77 g/t over 0.63m is below the project average, but contributes to the AgEq value and is important as part of the 450m step-out extension.

Positive factors

  • Contributes to the AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“0.77”

Context: 0.63

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH517 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH520Santa Ana · silverGrade: 265Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
DH520
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
265
Grade Unit
g/t
Intercept
0.7 m
From
158.24 m
To
158.94 m
Intercept Depth
158.24 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH520:158.24-158.94
Mining Method
underground

Location

Location
Aguilar
Easting
503237.175
Northing
560908.789
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.13 m
Azimuth
141 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
330
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 265 g/t Ag over 0.70m is a good result, significantly above the peer average of 86.788 g/t Ag, and is important as it's part of the 450m step-out extension.

Positive factors

  • Strong silver grade, well above peer average.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“265”

Context: 0.70

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH520 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH520Santa Ana · goldGrade: 0.73Grade Unit: g/tIntercept: 0.7 mView all details
Link to this fact

Identity

Hole ID
DH520
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
0.73
Grade Unit
g/t
Intercept
0.7 m
From
158.24 m
To
158.94 m
Intercept Depth
158.24 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH520:158.24-158.94
Mining Method
underground

Location

Location
Aguilar
Easting
503237.175
Northing
560908.789
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.13 m
Azimuth
141 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
330
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 0.73 g/t over 0.70m is below the project average, but contributes to the AgEq value and is important as part of the 450m step-out extension.

Positive factors

  • Contributes to the AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“0.73”

Context: 0.70

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH520 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH520Santa Ana · silverGrade: 473Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
DH520
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
473
Grade Unit
g/t
Intercept
0.35 m
From
158.59 m
To
158.94 m
Intercept Depth
158.24 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH520:158.59-158.94
Mining Method
underground

Location

Location
Aguilar
Easting
503237.175
Northing
560908.789
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.13 m
Azimuth
141 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
574
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 473 g/t Ag over 0.35m is a very strong high-grade intercept, well above the peer average of 86.788 g/t Ag, and is a key part of the 450m step-out extension.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Confirms high-grade mineralization within the broader interval as part of a significant step-out.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“473”

Context: 0.35

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH520 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH520Santa Ana · goldGrade: 1.15Grade Unit: g/tIntercept: 0.35 mView all details
Link to this fact

Identity

Hole ID
DH520
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1.15
Grade Unit
g/t
Intercept
0.35 m
From
158.59 m
To
158.94 m
Intercept Depth
158.24 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH520:158.59-158.94
Mining Method
underground

Location

Location
Aguilar
Easting
503237.175
Northing
560908.789
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.13 m
Azimuth
141 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
574
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 1.15 g/t over 0.35m, while below the project average, adds to the AgEq value and is important as part of the 450m step-out extension.

Positive factors

  • Contributes to the high AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“1.15”

Context: 0.35

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH520 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH524Santa Ana · silverGrade: 164Grade Unit: g/tIntercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
DH524
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
164
Grade Unit
g/t
Intercept
1.04 m
From
218 m
To
219.04 m
Intercept Depth
218 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH524:218-219.04
Mining Method
underground

Location

Location
Aguilar
Easting
503237.069
Northing
560909.078
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.05 m
Azimuth
141 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
779
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 164 g/t Ag over 1.04m is a good result, significantly above the peer average of 86.788 g/t Ag, and is important as it's part of the 450m step-out extension.

Positive factors

  • Strong silver grade, well above peer average.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“164”

Context: 1.04

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH524 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH524Santa Ana · goldGrade: 6.97Grade Unit: g/tIntercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
DH524
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
6.97
Grade Unit
g/t
Intercept
1.04 m
From
218 m
To
219.04 m
Intercept Depth
218 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH524:218-219.04
Mining Method
underground

Location

Location
Aguilar
Easting
503237.069
Northing
560909.078
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.05 m
Azimuth
141 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
779
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 6.97 g/t over 1.04m is a strong result, close to the project average, and significantly boosts the AgEq grade for this interval in the 450m step-out extension.

Positive factors

  • Strong gold grade, close to the project average (7.333 g/t Au).
  • Contributes significantly to the high AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“6.97”

Context: 1.04

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH524 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH524Santa Ana · silverGrade: 225Grade Unit: g/tIntercept: 0.74 mView all details
Link to this fact

Identity

Hole ID
DH524
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
225
Grade Unit
g/t
Intercept
0.74 m
From
218 m
To
218.74 m
Intercept Depth
218 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH524:218-218.74
Mining Method
underground

Location

Location
Aguilar
Easting
503237.069
Northing
560909.078
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.05 m
Azimuth
141 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1084
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 225 g/t Ag over 0.74m is a very strong high-grade intercept, well above the peer average of 86.788 g/t Ag, and is a key part of the 450m step-out extension.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Confirms high-grade mineralization within the broader interval as part of a significant step-out.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“225”

Context: 0.74

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH524 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH524Santa Ana · goldGrade: 9.74Grade Unit: g/tIntercept: 0.74 mView all details
Link to this fact

Identity

Hole ID
DH524
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
9.74
Grade Unit
g/t
Intercept
0.74 m
From
218 m
To
218.74 m
Intercept Depth
218 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH524:218-218.74
Mining Method
underground

Location

Location
Aguilar
Easting
503237.069
Northing
560909.078
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.05 m
Azimuth
141 °
Dip
-73 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1084
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 9.74 g/t over 0.74m is a strong result, above the project average, and significantly boosts the AgEq grade for this bonanza-grade sub-interval in the 450m step-out extension.

Positive factors

  • Strong gold grade, above the project average (7.333 g/t Au).
  • Contributes significantly to the bonanza AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.

Evidence · table

“9.74”

Context: 0.74

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The AgEq grade of 1,084 g/t over 0.74m is exceptionally high, well above the deposit-type norm of 86.788 g/t Ag.

Evidence · table

“1,084”

Context: 0.74

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH524 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH528Santa Ana · silverGrade: 102Grade Unit: g/tIntercept: 0.84 mView all details
Link to this fact

Identity

Hole ID
DH528
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
102
Grade Unit
g/t
Intercept
0.84 m
From
263.32 m
To
264.16 m
Intercept Depth
263.32 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH528:263.32-264.16
Mining Method
underground

Location

Location
Aguilar
Easting
503236.914
Northing
560909.205
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.02 m
Azimuth
141 °
Dip
-83 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
270
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 102 g/t Ag over 0.84m is above the peer average of 86.788 g/t Ag, but the AgEq grade is only slightly above the cut-off. Its significance lies in being part of the 450m step-out extension.

Positive factors

  • Silver grade is above the peer average.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • True width not estimated for step-out holes.
  • AgEq grade is just above the stated cut-off of 150 g/t AgEq.

Evidence · table

“102”

Context: 0.84

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH528 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH528Santa Ana · goldGrade: 1.9Grade Unit: g/tIntercept: 0.84 mView all details
Link to this fact

Identity

Hole ID
DH528
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1.9
Grade Unit
g/t
Intercept
0.84 m
From
263.32 m
To
264.16 m
Intercept Depth
263.32 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH528:263.32-264.16
Mining Method
underground

Location

Location
Aguilar
Easting
503236.914
Northing
560909.205
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1050.02 m
Azimuth
141 °
Dip
-83 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
270
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 1.90 g/t over 0.84m is below the project average, but contributes to the AgEq value and is important as part of the 450m step-out extension.

Positive factors

  • Contributes to the AgEq value.
  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated for step-out holes.

Evidence · table

“1.90”

Context: 0.84

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH528 is one of five drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH532Santa Ana · silverGrade: 392Grade Unit: g/tIntercept: 0.96 mView all details
Link to this fact

Identity

Hole ID
DH532
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
392
Grade Unit
g/t
Intercept
0.96 m
From
179.62 m
To
180.58 m
Intercept Depth
179.62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH532:179.62-180.58
Mining Method
underground

Location

Location
Aguilar
Easting
503568.197
Northing
561155.748
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1029.6 m
Azimuth
144 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 392 g/t Ag over 0.96m is a very strong high-grade result, well above the peer average of 86.788 g/t Ag, and is important for confirming the continuity of the high-grade shoot as part of the resource definition program.

Positive factors

  • Very high-grade silver intercept, significantly above peer average.
  • Part of the resource definition program, confirming continuity of the high-grade shoot.

Negative factors

  • True width not estimated.

Evidence · table

“392”

Context: 0.96

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH532 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH532Santa Ana · goldGrade: 1.97Grade Unit: g/tIntercept: 0.96 mView all details
Link to this fact

Identity

Hole ID
DH532
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1.97
Grade Unit
g/t
Intercept
0.96 m
From
179.62 m
To
180.58 m
Intercept Depth
179.62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH532:179.62-180.58
Mining Method
underground

Location

Location
Aguilar
Easting
503568.197
Northing
561155.748
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1029.6 m
Azimuth
144 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
566
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 1.97 g/t over 0.96m, while below the project average, adds to the AgEq value and is important for confirming the continuity of the high-grade shoot as part of the resource definition program.

Positive factors

  • Contributes to the high AgEq value.
  • Part of the resource definition program, confirming continuity of the high-grade shoot.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated.

Evidence · table

“1.97”

Context: 0.96

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH532 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH532Santa Ana · silverGrade: 619Grade Unit: g/tIntercept: 0.49 mView all details
Link to this fact

Identity

Hole ID
DH532
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
619
Grade Unit
g/t
Intercept
0.49 m
From
179.62 m
To
180.11 m
Intercept Depth
179.62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH532:179.62-180.11
Mining Method
underground

Location

Location
Aguilar
Easting
503568.197
Northing
561155.748
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1029.6 m
Azimuth
144 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
798
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 619 g/t Ag over 0.49m is a bonanza-grade intercept, well above the peer average of 86.788 g/t Ag, and strongly supports the high-grade potential of the Aguilar vein for resource definition.

Positive factors

  • Bonanza-grade silver intercept, significantly above peer average and project average.
  • Confirms high-grade mineralization within the broader interval as part of the resource definition program.

Negative factors

  • True width not estimated.

Evidence · table

“619”

Context: 0.49

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 619 g/t over 0.49m is exceptionally high, well above the deposit-type norm of 86.788 g/t Ag.

Evidence · table

“619”

Context: 0.49

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH532 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH532Santa Ana · goldGrade: 2.02Grade Unit: g/tIntercept: 0.49 mView all details
Link to this fact

Identity

Hole ID
DH532
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
2.02
Grade Unit
g/t
Intercept
0.49 m
From
179.62 m
To
180.11 m
Intercept Depth
179.62 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH532:179.62-180.11
Mining Method
underground

Location

Location
Aguilar
Easting
503568.197
Northing
561155.748
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1029.6 m
Azimuth
144 °
Dip
-72 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
798
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 2.02 g/t over 0.49m, while below the project average, significantly boosts the AgEq grade for this high-grade sub-interval and is important for resource definition.

Positive factors

  • Contributes to the high AgEq value.
  • Part of the resource definition program, confirming continuity of the high-grade shoot.

Negative factors

  • Gold grade is below the project average for gold (7.333 g/t).
  • True width not estimated.

Evidence · table

“2.02”

Context: 0.49

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH532 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH535Santa Ana · silverGrade: 835Grade Unit: g/tIntercept: 0.84 mView all details
Link to this fact

Identity

Hole ID
DH535
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
835
Grade Unit
g/t
Intercept
0.84 m
From
178.73 m
To
179.57 m
Intercept Depth
178.73 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH535:178.73-179.57
Mining Method
underground

Location

Location
Aguilar
Easting
503567.04
Northing
561156.89
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1030.23 m
Azimuth
114 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1659
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The intercept of 835 g/t Ag over 0.84m is a bonanza-grade result, well above the peer average of 86.788 g/t Ag, and is a key highlight for confirming the continuity of the high-grade shoot as part of the resource definition program.

Positive factors

  • Bonanza-grade silver intercept, significantly above peer average and project average.
  • Part of the resource definition program, confirming continuity of the high-grade shoot.

Negative factors

  • True width not estimated.

Evidence · table

“835”

Context: 0.84

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 835 g/t over 0.84m is exceptionally high, well above the deposit-type norm of 86.788 g/t Ag.

Evidence · table

“835”

Context: 0.84

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH535 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH535Santa Ana · goldGrade: 9.33Grade Unit: g/tIntercept: 0.84 mView all details
Link to this fact

Identity

Hole ID
DH535
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
9.33
Grade Unit
g/t
Intercept
0.84 m
From
178.73 m
To
179.57 m
Intercept Depth
178.73 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH535:178.73-179.57
Mining Method
underground

Location

Location
Aguilar
Easting
503567.04
Northing
561156.89
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1030.23 m
Azimuth
114 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
1659
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 9.33 g/t over 0.84m is a strong result, above the project average, and significantly boosts the AgEq grade for this bonanza-grade interval, important for resource definition.

Positive factors

  • Strong gold grade, above the project average (7.333 g/t Au).
  • Contributes significantly to the bonanza AgEq value.
  • Part of the resource definition program, confirming continuity of the high-grade shoot.

Negative factors

  • True width not estimated.

Evidence · table

“9.33”

Context: 0.84

Tags used in scoring

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH535 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH535Santa Ana · silverGrade: 1549Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
DH535
Project
Santa Ana
Commodity
silver
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
1549
Grade Unit
g/t
Intercept
0.45 m
From
179.12 m
To
179.57 m
Intercept Depth
178.73 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH535:179.12-179.57
Mining Method
underground

Location

Location
Aguilar
Easting
503567.04
Northing
561156.89
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1030.23 m
Azimuth
114 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3080
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: This included interval of 1,549 g/t Ag over 0.45m is an exceptional bonanza-grade result, well above the peer average of 86.788 g/t Ag and the project's best grade, and is a key highlight for confirming the continuity of the high-grade shoot for resource definition.

Positive factors

  • Exceptional bonanza-grade silver intercept, significantly above peer average and project average.
  • Confirms high-grade mineralization within the broader interval as part of the resource definition program.

Negative factors

  • True width not estimated.

Evidence · table

“1,549”

Context: 0.45

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The silver grade of 1,549 g/t over 0.45m is exceptionally high, well above the deposit-type norm of 86.788 g/t Ag and the project's best grade of 8022 g/t Ag.

Evidence · table

“1,549”

Context: 0.45

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH535 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH535Santa Ana · goldGrade: 17.35Grade Unit: g/tIntercept: 0.45 mView all details
Link to this fact

Identity

Hole ID
DH535
Project
Santa Ana
Commodity
gold
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Grade
17.35
Grade Unit
g/t
Intercept
0.45 m
From
179.12 m
To
179.57 m
Intercept Depth
178.73 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Group ID
DH535:179.12-179.57
Mining Method
underground

Location

Location
Aguilar
Easting
503567.04
Northing
561156.89
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1030.23 m
Azimuth
114 °
Dip
-61 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3080
Metal Eq. Unit
g/t AgEq
Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: The gold grade of 17.35 g/t over 0.45m is an exceptional bonanza-grade result, well above the project average and close to the project's best gold grade, and significantly boosts the AgEq grade for this bonanza-grade sub-interval, important for resource definition.

Positive factors

  • Exceptional bonanza-grade gold intercept, significantly above project average (7.333 g/t Au).
  • Contributes significantly to the bonanza AgEq value.
  • Part of the resource definition program, confirming continuity of the high-grade shoot.

Negative factors

  • True width not estimated.

Evidence · table

“17.35”

Context: 0.45

Tags used in scoring

Bonanza Interceptpositive

Exceptionally high-grade zone, well above the deposit-type norm.

Why it applies: The gold grade of 17.35 g/t over 0.45m is exceptionally high, well above the deposit-type norm of 1 g/t Au for underground epithermal and the project's average of 7.333 g/t Au.

Evidence · table

“17.35”

Context: 0.45

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: DH535 is part of the resource definition program, demonstrating that the previously known high-grade shoot remains open along strike and at depth.

Evidence · text

“DH532 and DH535 are part of the resource definition program and demonstrate that the previously known high-grade shoot remains open along strike and at depth (Figure 2).”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details standard protocols for sampling and assay, including certified labs, blanks, duplicates, and certified reference materials.

Evidence · text

“Outcrop Silver applied its standard protocols for sampling and assay for exploration activities. Core diameter is a mix of HTW and NTW, depending on the drill hole depth. Diamond drill core boxes were photographed, sawed, sampled, and tagged. Samples were bagged, tagged, and packaged for shipment by truck from Santa Ana's core logging facilities in Falan, Colombia to the Actlabs certified sample preparation facility in Medellin, Colombia . ActLabs is an accredited laboratory independent of the Company. HQ-NTW core is sawn with one-half shipped. Samples delivered to Actlabs were AA assayed on Au, Ag, Pb, and Zn at Medellin using 1A2Au, 1A3Au, Multi-elements AR (Ag Cu Pb Zn), and Code 8 methods. Then, samples were sent to Actlabs Canada in Ancaster, Ontario , for ICP multi-elemental analysis under code 1E3. In line with QA/QC best practices, blanks, duplicates, and certified reference materials are inserted into the sample stream at approximately 3 control samples every 20 samples to monitor laboratory performance. A comparison of control samples and their standard deviations indicates acceptable assay accuracy and no detectable contamination. No material QA/QC issues have been identified with respect to sample collection, security, and assaying. The samples are analyzed for gold and silver using a standard fire assay on a 30-gram sample with a gravimetric finish for over-limits. Multi-element geochemistry was determined by ICP-MS using either aqua regia or four acid digestions. Crush rejects, pulps, and the remaining core are stored in a secured facility at Santa Ana for future assay verification.”

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

Rejected tags

Rejected tags — excluded from scoring because their label or evidence could not be verified.

QP/CP SignedRejected · positive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Reason: Mr. Guillermo Hernandez, CPG-AIPG, Vice-President Exploration at Outcrop Silver, is a Qualified Person for the Company and has reviewed and approved the technical information.

Evidence · text

“The technical information contained in this news release has been reviewed and approved by Mr. Guillermo Hernandez , CPG-AIPG, Vice-President Exploration at Outcrop Silver. Mr. Hernandez is a Qualified Person for the Company as defined by National Instrument 43-101.”
DH511Santa AnaView all details
Link to this fact

Identity

Hole ID
DH511
Project
Santa Ana
Region
colombia
Reported Region
colombia
Ticker
OCG

Geometry

Hole Depth
160.87 m

Classification

Deposit Type
epithermal
Program
mixed
Sample Type
drill
Mining Method
underground

Location

Easting
503310.947
Northing
560819.904
CRS
UTM system, Zone 18N, WGS84 projection
Elevation
1053.51 m
Azimuth
137 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
Actlabs
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Assumptions Disclosed
Yes

Compositing

Cutoff Grade
150
Cutoff Unit
g/t AgEq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2025-11-26T00:00:00.000Z

Reasoning: DH511 is part of the significant step-out drilling but returned no significant results, indicating sub-economic mineralization in this specific intercept. This is a negative result for this particular hole, though it contributes to the overall understanding of the vein system.

Positive factors

  • Part of a 450m step-out, confirming vein continuity beneath cover.

Negative factors

  • No significant results reported for this hole, indicating sub-economic mineralization.
  • True width not estimated for step-out holes.

Evidence · table

“DH511”

Context: SAAG25DH511

Tags used in scoring

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: DH511 is one of the drill holes representing a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover.

Evidence · text

“Five drill holes (DH514, DH517, DH520, DH524, and DH528) represent a 450 metre step out to the south, confirming the Aguilar vein continues beneath volcanic cover and remains open along strike and at depth.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.

Evidence · text

“The current knowledge of the step-out in the Aguilar vein does not allow for estimating the true width of the intercepts.”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "The drilling campaign aims to extend known mineralization and test new high-potential areas along the permitted section "

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.